{"lab":{"_id":"69ad52a3de79e566650fb438","accr_number":"AB 836","country":"PL","accr_body":"PCA","address":"W JAROSŁAWIU Sp. z o. o., LABORATORIUM, ul. Hetmana J. Tarnowskiego 28, 37-500 Jarosław","categories":["water","microbiology"],"city":"Jarosław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":33,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI","parse_status":"parsed","parse_version":3,"pdf_files":["AB_836.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji w jarosławiu sp. z o. o., laboratorium, ul. hetmana j. tarnowskiego 28, 37-500 jarosław water other pharma electronics microbiology automotive","status":"active","updated_at":"2026-03-08T14:51:43.455Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:12:17.971Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20836,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling of water, drinking water, sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water and drinking water"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage"}],"issue":{"no":"19","date":"14.07.2026"},"parse_date":"2026-08-13T08:12:17.971Z","parse_source":"agent-claude-code","map_coord":[50.015903,22.679657],"map_geo":"nominatim-city","lab_locations":[{"name":"Pracownia Chemiczna Badania Ścieków","address":"ul. Wróblewskiego 3, 37-500 Jarosław","city":"Jarosław","postal":"37-500"},{"name":"Pracownia Chemiczna Badania Wody","address":"ul. Wodna 15, 37-514 Munina","city":"Munina","postal":"37-514"},{"name":"Pracownia Mikrobiologiczna Badania Wody","address":"ul. Wodna 15, 37-514 Munina","city":"Munina","postal":"37-514"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/c8a1cc884f467e1af9c845d7d6c267d5/AB%20836.pdf","has_en":true,"category_counts":{"water":33,"microbiology":5},"category_scores":{"water":28.66,"microbiology":0.66},"has_zh":true,"lab_locations_zh":[{"name":"废水检验化学室","address":"ul. Wróblewskiego 3, 37-500 Jarosław","city":"Jarosław","postal":"37-500"},{"name":"水质检验化学室","address":"ul. Wodna 15, 37-514 Munina","city":"Munina","postal":"37-514"},{"name":"水检验微生物室","address":"ul. Wodna 15, 37-514 Munina","city":"Munina","postal":"37-514"}]},"methods":[{"_id":"6a7d7c610636ba417e41c52f","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(1,0 – 35) 0C"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (1,0 – 35) 0C\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 z wył. p. 5.4 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11 z wył. p. 5.4","PN-77/C-04584"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (1,0 – 35) 0C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 z wył. p. 5.4 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (1,0 – 35) 0C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 z wyl. p. 5.4 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(1,0 – 35) 0C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Chemical Laboratory for Wastewater Testing Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 z wył. p. 5.4 | PN-77/C-04584","technique_en":"Manual and automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(1,0 – 35) 0C"}],"search_zh":"污水 化学与物理检测用样品采集 手工与自动法 废水检验化学室 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 z wył. p. 5.4 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"手工与自动法","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c530","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(1,0 – 35) 0C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 – 35) 0C","reference":"PN-EN ISO 5667-6:2016-12 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12","PN-77/C-04584"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura pobranej próbki wody\nZakres (1,0 – 35) 0C PN-EN ISO 5667-6:2016-12 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura pobranej probki wody\nZakres (1,0 – 35) 0C PN-EN ISO 5667-6:2016-12 | PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Sampling for chemical and physical testing Temperature of the water sample taken","parameters_en":[{"name":"Range","range":"(1,0 – 35) 0C"}],"search_en":"Water Sampling for chemical and physical testing Temperature of the water sample taken Chemical Laboratory for Wastewater Testing Range PN-EN ISO 5667-6:2016-12 | PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(1,0 – 35) 0C"}],"search_zh":"水 化学和物理检测采样 所采水样的温度 废水检验化学室 范围 PN-EN ISO 5667-6:2016-12 | PN-77/C-04584","test_object_zh":"水","methodology_zh":"化学和物理检测采样 所采水样的温度","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c531","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu amonowego\nZakres (0,050 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki, Woda Stezenie azotu amonowego\nZakres (0,050 – 100) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 100) mg/l"}],"search_en":"Wastewater, Water Ammonium nitrogen concentration Spectrophotometric method Chemical Laboratory for Wastewater Testing Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 100) mg/l"}],"search_zh":"废水、水 氨氮浓度 分光光度法 废水检验化学室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c532","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0125 – 2,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0125 – 2,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu azotynowego\nZakres (0,0125 – 2,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki, Woda Stezenie azotu azotynowego\nZakres (0,0125 – 2,5) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0125 – 2,5) mg/l"}],"search_en":"Wastewater, Water Nitrite nitrogen concentration Spectrophotometric method Chemical Laboratory for Wastewater Testing Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0125 – 2,5) mg/l"}],"search_zh":"废水、水 亚硝态氮浓度 分光光度法 废水检验化学室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c533","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 25) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu azotanowego\nZakres (0,10 – 25) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki, Woda Stezenie azotu azotanowego\nZakres (0,10 – 25) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 25) mg/l"}],"search_en":"Wastewater, Water Nitrate nitrogen concentration Spectrophotometric method Chemical Laboratory for Wastewater Testing Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 25) mg/l"}],"search_zh":"废水、水 硝态氮浓度 分光光度法 废水检验化学室 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c534","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu ogólnego, Z obliczeń","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego, Z obliczeń","reference":"PN-73/C-04576.14","norm_bases":["PN-73/C-04576.14"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu ogólnego, Z obliczeń PN-73/C-04576.14 Scieki, Woda Stezenie azotu ogolnego, Z obliczen PN-73/C-04576.14","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Total nitrogen concentration, Calculated","search_en":"Wastewater, Water Total nitrogen concentration, Calculated Chemical Laboratory for Wastewater Testing PN-73/C-04576.14","test_object_en":"Wastewater, Water","search_zh":"废水、水 废水检验化学室 PN-73/C-04576.14","test_object_zh":"废水、水","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c535","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(1,25 – 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (1,25 – 150) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu Kjeldahla\nZakres (1,25 – 150) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki, Woda Stezenie azotu Kjeldahla\nZakres (1,25 – 150) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,25 – 150) mg/l"}],"search_en":"Wastewater, Water Kjeldahl nitrogen concentration Titrimetric method Chemical Laboratory for Wastewater Testing Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater, Water","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(1,25 – 150) mg/l"}],"search_zh":"废水、水 凯氏氮浓度 滴定法 废水检验化学室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"废水、水","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c536","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,040 – 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,040 – 40) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 rozdz. 8 + Ap.1:2010: + Ap.2:2010","norm_bases":["PN-EN ISO 6878:2006 rozdz. 8 + Ap.1:2010: + Ap.2:2010"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie fosforu ogólnego\nZakres (0,040 – 40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdz. 8 + Ap.1:2010: + Ap.2:2010 Scieki, Woda Stezenie fosforu ogolnego\nZakres (0,040 – 40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 rozdz. 8 + Ap.1:2010: + Ap.2:2010","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,040 – 40) mg/l"}],"search_en":"Wastewater, Water Total phosphorus concentration Spectrophotometric method Chemical Laboratory for Wastewater Testing Range PN-EN ISO 6878:2006 rozdz. 8 + Ap.1:2010: + Ap.2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 40) mg/l"}],"search_zh":"废水、水 总磷浓度 分光光度法 废水检验化学室 范围 PN-EN ISO 6878:2006 rozdz. 8 + Ap.1:2010: + Ap.2:2010","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c537","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Chemiczne zapotrzebowanie tlenu SP-ChZT","parameters":[{"name":"Zakres","range":"(10 – 4000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu SP-ChZT\nZakres (10 – 4000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Chemiczne zapotrzebowanie tlenu SP-ChZT\nZakres (10 – 4000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, Woda Chemiczne zapotrzebowanie tlenu SP-ChZT\nZakres (10 – 4000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Chemical oxygen demand SP-COD","parameters_en":[{"name":"Range","range":"(10 – 4000) mg/l O2"}],"search_en":"Wastewater, Water Chemical oxygen demand SP-COD Spectrophotometric method Chemical Laboratory for Wastewater Testing Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","parameters_zh":[{"name":"范围","range":"(10 – 4000) mg/l O2"}],"search_zh":"废水、水 分光光度法 废水检验化学室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"废水、水","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c538","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12 IR-PCHŚ-120/PO-6 wyd. nr 1 z dnia 16.03.2020","norm_bases":["PN-EN ISO 5815-1:2019-12 IR-PCHŚ-120/PO-6 wyd. nr 1 z dnia 16.03.2020"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 IR-PCHŚ-120/PO-6 wyd. nr 1 z dnia 16.03.2020 Scieki, Woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 IR-PCHS-120/PO-6 wyd. nr 1 z dnia 16.03.2020","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1 – 6000) mg/l O2"}],"search_en":"Wastewater, Water Biochemical oxygen demand Optical method Chemical Laboratory for Wastewater Testing BOD5 Range PN-EN ISO 5815-1:2019-12 IR-PCHŚ-120/PO-6 wyd. nr 1 z dnia 16.03.2020","technique_en":"Optical method","test_object_en":"Wastewater, Water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"废水、水 生化需氧量 光学法 废水检验化学室 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12 IR-PCHŚ-120/PO-6 wyd. nr 1 z dnia 16.03.2020","technique_zh":"光学法","test_object_zh":"废水、水","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c539","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007 + Ap. 1:2007","norm_bases":["PN-EN 872:2007 + Ap. 1:2007"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (5,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap. 1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (5,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007 + Ap. 1:2007","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Chemical Laboratory for Wastewater Testing Range PN-EN 872:2007 + Ap. 1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 废水检验化学室 范围 PN-EN 872:2007 + Ap. 1:2007","technique_zh":"重量法","test_object_zh":"水、污水","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c53a","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie substancji organicznych ekstrahujących się eterem naftowym","parameters":[{"name":"Zakres","range":"(5,0 – 300) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie substancji organicznych ekstrahujących się eterem naftowym\nZakres (5,0 – 300) mg/l\nMetoda wagowa","reference":"PN-86/C-04573.01","norm_bases":["PN-86/C-04573.01"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie substancji organicznych ekstrahujących się eterem naftowym\nZakres (5,0 – 300) mg/l\nMetoda wagowa PN-86/C-04573.01 Woda, Scieki Stezenie substancji organicznych ekstrahujacych sie eterem naftowym\nZakres (5,0 – 300) mg/l\nMetoda wagowa PN-86/C-04573.01","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Concentration of organic substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(5,0 – 300) mg/l"}],"search_en":"Water, Wastewater Concentration of organic substances extractable with petroleum ether Gravimetric method Chemical Laboratory for Wastewater Testing Range PN-86/C-04573.01","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(5,0 – 300) mg/l"}],"search_zh":"水、污水 石油醚可萃取有机物质浓度 重量法 废水检验化学室 范围 PN-86/C-04573.01","technique_zh":"重量法","test_object_zh":"水、污水","lab_section_zh":"废水检验化学室","methodology_zh":"石油醚可萃取有机物质浓度"},{"_id":"6a7d7c610636ba417e41c53b","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 1600) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 1600) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (5,0 – 1600) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (5,0 – 1600) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1600) mg/l"}],"search_en":"Water, Wastewater Chloride concentration Titrimetric method Chemical Laboratory for Wastewater Testing Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1600) mg/l"}],"search_zh":"水、污水 氯化物浓度 滴定法 废水检验化学室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c53c","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, Wastewater pH Potentiometric method Chemical Laboratory for Wastewater Testing Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、污水 pH 值 电位法 废水检验化学室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c53d","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Pracownia Chemiczna Badania Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (10 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Scieki Stezenie siarczanow\nZakres (10 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Wastewater Testing","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 500) mg/l"}],"search_en":"Water, Wastewater Sulfate concentration Gravimetric method Chemical Laboratory for Wastewater Testing Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 500) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 重量法 废水检验化学室 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、污水","lab_section_zh":"废水检验化学室"},{"_id":"6a7d7c610636ba417e41c53e","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(0,040 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (0,040 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04605/02","norm_bases":["PN-92/C-04605/02"],"lab_section":"Pracownia Chemiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie glinu\nZakres (0,040 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04605/02 Woda, Woda do spozycia przez ludzi Stezenie glinu\nZakres (0,040 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04605/02","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Water Testing","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(0,040 – 1,0) mg/l"}],"search_en":"Water, Water intended for human consumption Aluminium concentration Spectrophotometric method Chemical Laboratory for Water Testing Range PN-92/C-04605/02","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,040 – 1,0) mg/l"}],"search_zh":"水、生活饮用水 铝浓度 分光光度法 水质检验化学室 范围 PN-92/C-04605/02","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"铝浓度","lab_section_zh":"水质检验化学室"},{"_id":"6a7d7c610636ba417e41c53f","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,040 – 0,74) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,040 – 0,74) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Pracownia Chemiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,040 – 0,74) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,040 – 0,74) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Water Testing","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,040 – 0,74) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrite concentration Spectrophotometric method Chemical Laboratory for Water Testing Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 0,74) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 水质检验化学室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水质检验化学室"},{"_id":"6a7d7c610636ba417e41c540","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 50) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 50) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Pracownia Chemiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 50) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Water Testing","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 50) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Chemical Laboratory for Water Testing Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 50) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 水质检验化学室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水","lab_section_zh":"水质检验化学室"},{"_id":"6a7d7c610636ba417e41c541","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 + Ap1:2015-06 pkt.7","norm_bases":["PN-EN ISO 7887:2012 + Ap1:2015-06 pkt.7"],"lab_section":"Pracownia Chemiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 + Ap1:2015-06 pkt.7 Woda, Woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 + Ap1:2015-06 pkt.7","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Water Testing","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"search_en":"Water, Water intended for human consumption Colour Visual method Chemical Laboratory for Water Testing Range PN-EN ISO 7887:2012 + Ap1:2015-06 pkt.7","technique_en":"Visual method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 水质检验化学室 范围 PN-EN ISO 7887:2012 + Ap1:2015-06 pkt.7","technique_zh":"目视法","test_object_zh":"水、生活饮用水","lab_section_zh":"水质检验化学室"},{"_id":"6a7d7c610636ba417e41c542","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Pracownia Chemiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Water Testing","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, Water intended for human consumption pH Potentiometric method Chemical Laboratory for Water Testing Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 水质检验化学室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水","lab_section_zh":"水质检验化学室"},{"_id":"6a7d7c610636ba417e41c543","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(148 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (148 – 2500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Pracownia Chemiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (148 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (148 – 2500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Water Testing","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(148 – 2500) μS/cm"}],"search_en":"Water, Water intended for human consumption Electrical conductivity Conductometric method Chemical Laboratory for Water Testing Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(148 – 2500) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 水质检验化学室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水","lab_section_zh":"水质检验化学室"},{"_id":"6a7d7c610636ba417e41c544","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(33 – 700) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (33 – 700) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Pracownia Chemiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (33 – 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (33 – 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Water Testing","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(33 – 700) mg/l CaCO3"}],"search_en":"Water, Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Chemical Laboratory for Water Testing Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(33 – 700) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 水质检验化学室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","lab_section_zh":"水质检验化学室"},{"_id":"6a7d7c610636ba417e41c545","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,030 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,030 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Pracownia Chemiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,030 – 2,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,030 – 2,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Water Testing","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,030 – 2,0) mg/l"}],"search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Chemical Laboratory for Water Testing Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,030 – 2,0) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 水质检验化学室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水质检验化学室"},{"_id":"6a7d7c610636ba417e41c546","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,40 – 60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,40 – 60) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Pracownia Chemiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,40 – 60) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,40 – 60) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Water Testing","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,40 – 60) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrate concentration Spectrophotometric method Chemical Laboratory for Water Testing Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,40 – 60) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 水质检验化学室 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水质检验化学室"},{"_id":"6a7d7c610636ba417e41c547","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,010 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+ Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+ Ap1:2016-06"],"lab_section":"Pracownia Chemiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+ Ap1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+ Ap1:2016-06","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Water Testing","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,010 – 5,0) mg/l"}],"search_en":"Water, Water intended for human consumption Total iron concentration Spectrophotometric method Chemical Laboratory for Water Testing Range PN-ISO 6332:2001+ Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 5,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 水质检验化学室 范围 PN-ISO 6332:2001+ Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","lab_section_zh":"水质检验化学室"},{"_id":"6a7d7c610636ba417e41c548","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Pracownia Chemiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Water Testing","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Chemical Laboratory for Water Testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 水质检验化学室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","lab_section_zh":"水质检验化学室"},{"_id":"6a7d7c610636ba417e41c549","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Pracownia Chemiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Chemical Laboratory for Water Testing","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption Sampling for microbiological testing Chemical Laboratory for Water Testing PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水 微生物检测用样品采集 水质检验化学室 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水","lab_section_zh":"水质检验化学室"},{"_id":"6a7d7c610636ba417e41c54a","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w 22oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Pracownia Mikrobiologiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w 22oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w 22oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory for Water Testing","methodology_en":"Total viable count at 22oC","search_en":"Water Total viable count at 22oC Plate method (pour plate) Microbiology Laboratory for Water Testing PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water","search_zh":"水 22oC 微生物总数 平板法（倾注培养） 水检验微生物室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水","methodology_zh":"22oC 微生物总数","lab_section_zh":"水检验微生物室"},{"_id":"6a7d7c610636ba417e41c54b","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii grupy coli, grupy coli termotolerancyjnych i domniemanych, Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli, grupy coli termotolerancyjnych i domniemanych, Escherichia coli\nMetoda filtracji membranowej","reference":"PN-ISO 9308-1:1999","norm_bases":["PN-ISO 9308-1:1999"],"lab_section":"Pracownia Mikrobiologiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii grupy coli, grupy coli termotolerancyjnych i domniemanych, Escherichia coli\nMetoda filtracji membranowej PN-ISO 9308-1:1999 Woda Liczba bakterii grupy coli, grupy coli termotolerancyjnych i domniemanych, Escherichia coli\nMetoda filtracji membranowej PN-ISO 9308-1:1999","categories":["microbiology","water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory for Water Testing","methodology_en":"Count of coliform bacteria, thermotolerant and presumptive coliforms, Escherichia coli","search_en":"Water Count of coliform bacteria, thermotolerant and presumptive coliforms, Escherichia coli Membrane filtration method Microbiology Laboratory for Water Testing PN-ISO 9308-1:1999","technique_en":"Membrane filtration method","test_object_en":"Water","search_zh":"水 膜过滤法 水检验微生物室 PN-ISO 9308-1:1999","technique_zh":"膜过滤法","test_object_zh":"水","lab_section_zh":"水检验微生物室"},{"_id":"6a7d7c610636ba417e41c54c","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Pracownia Mikrobiologiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory for Water Testing","methodology_en":"Intestinal enterococci count","search_en":"Water Intestinal enterococci count Membrane filtration method Microbiology Laboratory for Water Testing PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"粪肠球菌计数","search_zh":"水 粪肠球菌计数 膜过滤法 水检验微生物室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水","lab_section_zh":"水检验微生物室"},{"_id":"6a7d7c610636ba417e41c54d","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PB-PMW-3 wydanie 1 z dnia 16.03.2020 r.","norm_bases":["PB-PMW-3 wydanie 1 z dnia 16.03.2020 r."],"lab_section":"Pracownia Mikrobiologiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PB-PMW-3 wydanie 1 z dnia 16.03.2020 r. Woda Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PB-PMW-3 wydanie 1 z dnia 16.03.2020 r.","categories":["microbiology","water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory for Water Testing","methodology_en":"Escherichia coli count","search_en":"Water Escherichia coli count Membrane filtration method Microbiology Laboratory for Water Testing PB-PMW-3 wydanie 1 z dnia 16.03.2020 r.","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 水检验微生物室 PB-PMW-3 wydanie 1 z dnia 16.03.2020 r.","technique_zh":"膜过滤法","test_object_zh":"水","lab_section_zh":"水检验微生物室"},{"_id":"6a7d7c610636ba417e41c54e","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04","norm_bases":["PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04"],"lab_section":"Pracownia Mikrobiologiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04 Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04","categories":["water","microbiology"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory for Water Testing","methodology_en":"Coliform bacteria count","search_en":"Water Coliform bacteria count Membrane filtration method Microbiology Laboratory for Water Testing PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"大肠菌群计数","search_zh":"水 大肠菌群计数 膜过滤法 水检验微生物室 PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04","technique_zh":"膜过滤法","test_object_zh":"水","lab_section_zh":"水检验微生物室"},{"_id":"6a7d7c610636ba417e41c54f","lab_id":"69ad52a3de79e566650fb438","country":"PL","accr_number":"AB 836","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04","norm_bases":["PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04"],"lab_section":"Pracownia Mikrobiologiczna Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04 Woda Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04","categories":["microbiology","water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Microbiology Laboratory for Water Testing","methodology_en":"Escherichia coli count","search_en":"Water Escherichia coli count Membrane filtration method Microbiology Laboratory for Water Testing PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 水检验微生物室 PN-EN ISO 9308 – 1:2014-12 + A1/:2017-04","technique_zh":"膜过滤法","test_object_zh":"水","lab_section_zh":"水检验微生物室"}],"has_pdf":true}