🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL
Water & wastewaterEnvironmentMicrobiology
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 814 (Gliwice, Poland). Its accreditation scope covers 98 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Water, water intended for human consumption, wastewater, Water, water intended for human consumption, Odpady O) kod: 19 08 05, Wastewater. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Flame atomic absorption spectrometry (FAAS).
At a glance
- Accreditation number: PCA AB 814
- Methods in scope: 98
- Types of test objects: 9
- Techniques used: 21
- City: Gliwice, Poland
- Accreditation number
- AB 814
- Accreditation body
- PCA
- Address
- ul. Rybnicka 47, 44-100 Gliwice, DZIAŁ LABORATORIUM, ul. T. Edisona 16
- City
- Gliwice, Poland
What this laboratory tests (9)
- Water, water intended for human consumption, wastewater — 27 methods
- Water, water intended for human consumption — 21 methods
- Odpady O) kod: 19 08 05 — 17 methods
- Wastewater — 14 methods
- Water, Water intended for human consumption — 9 methods
- Water — 6 methods
- Rainwater, snowmelt water — 2 methods
- Water intended for human consumption — 1 method
- Water, wastewater, rainwater, snowmelt water — 1 method
Analytical techniques used (21)
- Spectrophotometric method — 15 methods
- Titrimetric method — 14 methods
- Flame atomic absorption spectrometry (FAAS) — 10 methods
- Gravimetric method — 9 methods
- Membrane filtration method — 6 methods
- Inductively coupled plasma optical emission spectrometry (ICP-OES) — 4 methods
- Cold vapour atomic absorption spectrometry (CVAAS) — 3 methods
- Electrothermal atomization atomic absorption spectrometry (ETAAS) — 3 methods
- Ion chromatography with conductometric detection (IC-CD) — 3 methods
- Hydride generation atomic absorption spectrometry (HGAAS) — 2 methods
- Optical method — 2 methods
- Plate method (pour plate) — 2 methods
- Potentiometric method — 2 methods
- Conductometric method — 1 method
- Culture method with biochemical confirmation — 1 method
- and 6 more
Laboratory locations
- DZIAŁ LABORATORIUM — ul. T. Edisona 16
Accreditation scope — test methods (98)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Dział Laboratorium | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing Temperature Range (2,0 – 50,0) °C |
PN-ISO 5667-5:2017-10 | PN-77/C-04584 | ||
| 2 | Water | Sampling for chemical and physical testing Temperature of water/collected water sample Range (2,0 – 70,0) °C |
PN-ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6 | PN-77/C-04584 | ||
| 3 | Water | Kjeldahl nitrogen concentration Range (2,0 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 4 | Water | Total nitrogen concentration (calculated) | PB-05/KJ-7.2 wydanie 01 z dnia 13.01.2020 r. | ||
| 5 | Water | Phenol index Range (0,010 – 5,0) mg/l |
Spectrophotometric method | PN ISO 6439:1994 | |
| 6 | Water | Ammonium nitrogen concentration Range (2,0 – 1000) mg/l Ammonium ion concentration Range (2,6 – 1280) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 7 | Water | Element concentration Cadmium (0,010 – 0,5) mg/l Lead (0,0050 – 0,5) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 8 | Water, water intended for human consumption | Calcium concentration Range (0,05 – 25) mmol/l Range (2 – 1000) mg/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 9 | Water, water intended for human consumption | Magnesium concentration (calculated) | PN-C-04554-1:1999 zał. A | ||
| 10 | Water, water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (0,05 – 100) mmol/l Range (5,0 – 10000) mg/l CaCO 3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 11 | Water, water intended for human consumption | Turbidity Range (0,20 – 100) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 12 | Water, water intended for human consumption | Colour Range (5,0 – 80) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 Metoda C | |
| 13 | Water, water intended for human consumption | Calcium concentration Range (3,0 – 1000) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-EN ISO 7980:2002 | |
| 14 | Water, water intended for human consumption | Magnesium concentration Range (1,0 – 150) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-EN ISO 7980:2002 | |
| 15 | Water, water intended for human consumption | Mercury concentration Range (0,00020 – 0,0020) mg/l |
Cold vapour atomic absorption spectrometry (CVAAS) | PN-EN ISO 12846:2012+Ap1:2016-07 | |
| 16 | Water, water intended for human consumption | Ammonium ion concentration Range (0,064 – 2,6) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 17 | Water, water intended for human consumption | Permanganate index Range (0,50 – 10) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 18 | Water, water intended for human consumption | Bromate concentration Range (1,0 – 100) μg/l |
Ion chromatography with spectrophotometric detection (IC-UV/Vis) | PN-EN ISO 11206:2013-07 | |
| 19 | Water, water intended for human consumption | Chlorate concentration Range (0,050 – 10) mg/l Chlorite concentration Range (0,050 – 10) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-4:2022-08 | |
| 20 | Water, water intended for human consumption | Sum of chlorates and chlorites (calculated) | PN-EN ISO 10304-4:2022-08 | ||
| 21 | Water, water intended for human consumption | Nitrate concentration Range (0,18 – 200) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 22 | Water, water intended for human consumption | Nitrite concentration Range (0,030 – 30) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 23 | Water, water intended for human consumption | Anion concentrations: nitrates (1,0 – 500) mg/l nitrites (0,050 – 50) mg/l fluorides (0,050 – 20) mg/l chlorides (1,00 – 5000) mg/l sulfates (1,00 – 5000) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 24 | Water, water intended for human consumption | Element concentration Barium (0,010 – 2,5) mg/l Boron (0,010 – 2,5) mg/l Total chromium (0,0050 – 0,5) mg/l Zinc (0,020 – 2,0) mg/l Phosphorus (0,10 – 50) mg/l Aluminium (0,0100 – 5) mg/l Magnesium (1,0 – 200) mg/l Manganese (0,0020 – 1,5) mg/l Molybdenum (0,010 – 0,5) mg/l Copper (0,0050 – 2,5) mg/l Nickel (0,0050– 0,50) mg/l Potassium (1,0 – 200) mg/l Sodium (1,00– 250) mg/l Vanadium (0,010 – 0,5) mg/l Calcium (1,0 – 200) mg/l Iron (0,00200 – 20) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 25 | Water, water intended for human consumption | Free chlorine concentration Range (0,02 – 3,0) mg/l Regulated area: Badania wykonywane poza siedzibą Laboratorium |
Spectrophotometric method | PN-EN ISO 7893-2:2018-04 | |
| 26 | Water, water intended for human consumption | Total chlorine concentration Range (0,02 – 3,0) mg/l Regulated area: Badania wykonywane poza siedzibą Laboratorium |
Spectrophotometric method | PN-EN ISO 7893-2:2018-04 | |
| 27 | Water, water intended for human consumption | Chloramine concentration (calculated) | PN-EN ISO 7893-2:2018-04 | ||
| 28 | Water, water intended for human consumption | Ozone concentration Range (0,01 – 0,65) mg/l Regulated area: Badania wykonywane poza siedzibą Laboratorium |
Spectrophotometric method | PB-11/KJ-7.2 wyd. 02 z dnia 07.01.2026 r. | |
| 29 | Water, wastewater, rainwater, snowmelt water | Mineral oil index Range (0,010 – 100) mg/l |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 9377-2:2003 | |
| 30 | Rainwater, snowmelt water | Sampling for chemical and physical testing Temperature Range (2,0 – 50,0)°C |
Manual method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 31 | Rainwater, snowmelt water | Total suspended solids (TSS) Range (2,0 – 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 32 | Wastewater | Sampling for chemical and physical testing Temperature Range (2,0 – 50,0)°C |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 33 | Wastewater | Nitrate nitrogen concentration Range (0,04 – 50) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 34 | Wastewater | Element concentration Antimony (0,0050 – 0,50) mg/l Selenium (0,0050 – 0,50) mg/l |
Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN ISO 15586:2005 | |
| 35 | Wastewater | Element concentration Barium (0,010 – 2,5) mg/l Boron (0,010 – 2,5) mg/l Total chromium (0,0050 – 0,5) mg/l Zinc (0,020 – 2,0) mg/l Phosphorus (0,10 – 500) mg/l Aluminium (0,010 – 5,0) mg/l Cadmium (0,010 – 0,5) mg/l Magnesium (1,0 – 200) mg/l Manganese (0,0020 – 1,5) mg/l Molybdenum (0,010 – 0,5) mg/l Copper (0,0050 – 2,5) mg/l Nickel (0,0050 – 0,5) mg/l Lead (0,0050 – 0,5) mg/l Potassium (1,0 – 200) mg/l Sodium (1,0 – 250) mg/l Vanadium (0,010 – 0,5) mg/l Calcium (1,0 – 200) mg/l Iron (0,0020 – 20) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 36 | Wastewater | Ammonium nitrogen concentration Range (2,0 – 1000) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 37 | Wastewater | Nitrite nitrogen concentration Range (0,01 – 10) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 38 | Wastewater | Anion concentrations: nitrate nitrogen (0,30 – 100) mg/l nitrite nitrogen (0,015 – 15) mg/l fluorides (0,050 – 20) mg/l chlorides (1,0 – 5000) mg/l sulfates (1,0 – 5000) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 39 | Wastewater | Phosphate concentration Range (0,15 – 100) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | |
| 40 | Wastewater | Total phosphorus concentration Range (0,050 – 35,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 | |
| 41 | Wastewater | Kjeldahl nitrogen concentration Range (2,0 – 1000) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 42 | Wastewater | Total nitrogen concentration (calculated) | PB-05/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. | ||
| 43 | Wastewater | Mercury concentration Range (0,00020 – 0,10) mg/l |
Cold vapour atomic absorption spectrometry (CVAAS) | PN-EN ISO 12846:2012+Ap1:2016-07 | |
| 44 | Wastewater | Ammonium nitrogen concentration Range (0,050 – 2,5) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 45 | Wastewater | Phenol index Range (0,010 – 5,0) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 | |
| 46 | Water, water intended for human consumption, wastewater | Electrical conductivity Range (10 – 20000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 47 | Water, water intended for human consumption, wastewater | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 48 | Water, water intended for human consumption, wastewater | Potassium concentration Range (0,5 – 200) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 9964-2:1994+Ak:1997 | |
| 49 | Water, water intended for human consumption, wastewater | Chloride concentration Range (5,0 – 4000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 50 | Water, water intended for human consumption, wastewater | Metal concentrations Arsenic (0,0030 – 0,10) mg/l Manganese (0,0015 – 1,5) mg/l Iron (0,00150 – 3,0) mg/l Cadmium (0,00040 – 0,10) mg/l Cobalt (0,0050 – 2,0) mg/l Copper (0,0015 – 2,5) mg/l Lead (0,0015 – 0,50) mg/l Total chromium (0,0020 – 0,50) mg/l Nickel (0,0050 – 0,50) mg/l Silver (0,0010 – 0,10) mg/l Vanadium (0,0020 – 0,10) mg/l |
Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN ISO 15586:2005 | |
| 51 | Water, water intended for human consumption, wastewater | Sodium concentration Range (2,00 – 250) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 9964-1:1994+Ap1:2009 | |
| 52 | Water, water intended for human consumption, wastewater | Zinc concentration Range (0,1 – 2,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002 Metoda A | |
| 53 | Water, water intended for human consumption, wastewater | Copper concentration Range (0,050 – 2,5) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002 Metoda A | |
| 54 | Water, water intended for human consumption, wastewater | Sulfate concentration Range (10 – 5000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 55 | Water, water intended for human consumption, wastewater | Antimony concentration Range (0,0010 – 0,10) mg/l |
Hydride generation atomic absorption spectrometry (HGAAS) | PB-10/KJ-7.2 wyd. 02 z dnia 24.04.2025 r. | |
| 56 | Water, water intended for human consumption, wastewater | Selenium concentration Range (0,0010 – 0,10) mg/l |
Hydride generation atomic absorption spectrometry (HGAAS) | PN-ISO 9965:2001 | |
| 57 | Water, water intended for human consumption, wastewater | Total alkalinity Range (0,4 – 100) mmol/l |
Titrimetric method | PN-EN ISO 9963-1:2001+Ap1:2004 | |
| 58 | Water, water intended for human consumption, wastewater | Carbonate hardness (calculated) | PN-EN ISO 9963-1:2001+Ap1:2004 | ||
| 59 | Water, water intended for human consumption, wastewater | Bicarbonate concentration (calculated) | PN-EN ISO 9963-1:2001+Ap1:2004 | ||
| 60 | Water, water intended for human consumption, wastewater | Total suspended solids (TSS) Range (2,0 – 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 61 | Water, water intended for human consumption, wastewater | Chemical oxygen demand COD-Cr Range (15,0 – 4000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 62 | Water, water intended for human consumption, wastewater | Biochemical oxygen demand BOD5 Range (0,50 – 6,0) mg/l O2 |
Titrimetric method | PN-EN 1899-2:2002 | |
| 63 | Water, water intended for human consumption, wastewater | Biochemical oxygen demand BOD5 Range (3 – 6000) mg/l O2 |
Titrimetric method | PN-EN ISO 5815-1:2019-12 | |
| 64 | Water, water intended for human consumption, wastewater | Dissolved oxygen concentration Range (0,5 – 15,0) mg/l O2 |
Titrimetric method | PN-EN 25813:1997 | |
| 65 | Water, water intended for human consumption, wastewater | Total dissolved solids (TDS) Range (10,0 – 5000) mg/l |
Gravimetric method | PN-EN 15216:2022-03 | |
| 66 | Water, water intended for human consumption, wastewater | Mineral dissolved solids Range (10,0 – 5000) mg/l |
Gravimetric method | PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r. | |
| 67 | Water, water intended for human consumption, wastewater | Volatile dissolved solids (calculated) | PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r. | ||
| 68 | Water, water intended for human consumption, wastewater | Dry residue Range (10,0 – 5000) mg/l |
Gravimetric method | PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r. | |
| 69 | Water, water intended for human consumption, wastewater | Residue on ignition Range (10,0 – 5000) mg/l |
Gravimetric method | PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r. | |
| 70 | Water, water intended for human consumption, wastewater | Loss on ignition (calculated) | PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r. | ||
| 71 | Water, water intended for human consumption, wastewater | Biochemical oxygen demand BOD5 Range (3 – 6000) mg/l O2 |
Optical method | PN-EN ISO 5815-1:2019-12 | |
| 72 | Water, water intended for human consumption, wastewater | Biochemical oxygen demand BOD5 Range (0,50 – 6,0) mg/l O2 |
Optical method | PN-EN 1899-2:2002 z wył. pkt. 7.2 | ISO 17289:2014 | |
| 73 | Water, Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6 | ||
| 74 | Water, Water intended for human consumption | Ogólna liczba mikroorganizmów w temp. (36 ± 2) ºC po 48h | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 75 | Water, Water intended for human consumption | Ogólna liczba mikroorganizmów w temp. (22 ± 2) ºC po 72h | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 76 | Water, Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017 | |
| 77 | Water, Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017 | |
| 78 | Water, Water intended for human consumption | Enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 79 | Water, Water intended for human consumption | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 80 | Water, Water intended for human consumption | Count of bacteria of the genus Legionella Matrix A Procedure 5 (medium A – BCYE) Procedure 7 (medium C – GVPC) Range od 1 jtk/ 100 ml Range od 1 jtk/ 1000 ml |
Membrane filtration method | PN-EN ISO 11731-2:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019:12 | |
| 81 | Water, Water intended for human consumption | Clostridium perfingens count (including spores) | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 82 | Odpady O) kod: 19 08 05 | Sampling for chemical, physical and microbiological testing Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
PN-EN ISO 5667-13:2011 | ||
| 83 | Odpady O) kod: 19 08 05 | pH Range 2,0 – 12,0 Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 84 | Odpady O) kod: 19 08 05 | Residue on ignition Range (0,5 – 99,5) % Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Gravimetric method | PN-EN 15935:2022-01 | |
| 85 | Odpady O) kod: 19 08 05 | Loss on ignition (calculated) Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
PN-EN 15935:2022-01 | ||
| 86 | Odpady O) kod: 19 08 05 | Dry residue Range (0,5 – 99,5) % Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Gravimetric method | PN-EN 15934:2013-02 | |
| 87 | Odpady O) kod: 19 08 05 | Water content (calculated) Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
PN-EN 15934:2013-02 | ||
| 88 | Odpady O) kod: 19 08 05 | Kjeldahl nitrogen content Range (0,5 – 10) % Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Titrimetric method | PN-EN 13342:2002 | |
| 89 | Odpady O) kod: 19 08 05 | Ammonium nitrogen content Range (0,1 – 5,0) % Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Titrimetric method | PB-08/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. | |
| 90 | Odpady O) kod: 19 08 05 | Zinc content Range (100 – 2000) mg/kg Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. | |
| 91 | Odpady O) kod: 19 08 05 | Copper content Range (50 – 2000) mg/kg Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. | |
| 92 | Odpady O) kod: 19 08 05 | Metal content Total chromium (2,0 – 500) mg/kg Nickel (7,0 – 500) mg/kg Cadmium (0,40 – 100) mg/kg Copper (1,5 – 2000) mg/kg Lead (3,0 – 500) mg/kg Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Electrothermal atomization atomic absorption spectrometry (ETAAS) | PN-EN ISO 15586:2005 | |
| 93 | Odpady O) kod: 19 08 05 | Calcium content Range (500 – 200000) mg/kg Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Flame atomic absorption spectrometry (FAAS) | PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. | |
| 94 | Odpady O) kod: 19 08 05 | Magnesium content Range (50 – 100000) mg/kg Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Flame atomic absorption spectrometry (FAAS) | PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. | |
| 95 | Odpady O) kod: 19 08 05 | Mercury content Range (0,50 – 5,0) mg/kg Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Cold vapour atomic absorption spectrometry (CVAAS) | PN-EN ISO 12846:2012+Ap1:2016-07 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. | |
| 96 | Odpady O) kod: 19 08 05 | Element content Total chromium (5 – 500) mg/kg Zinc (20 – 2000) mg/kg Total phosphorus (1000 – 50000) mg/kg Cadmium (10 – 500) mg/kg Magnesium (1000 – 100000) mg/kg Copper (5 – 2000) mg/kg Nickel (10 – 500) mg/kg Lead (5 – 500) mg/kg Calcium (1000 – 200000) mg/kg Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. | |
| 97 | Odpady O) kod: 19 08 05 | Obecność bakterii z rodzaju Salmonella w 10 g Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Culture method with biochemical confirmation | PB-01/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. | |
| 98 | Odpady O) kod: 19 08 05 | Presence and number of viable eggs of intestinal parasites ATT (Ascaris sp., Trichuris sp., Toxocara sp.) Range od 1 w kg s.m. Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów. |
Metoda flotacyjno-sedymentacyjno-mikroskopowa | PN-Z-19005:2018-10 | |
Reference standards (67)
I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
ISO 17289:2014
PB-01/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
PB-05/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
PB-05/KJ-7.2 wydanie 01 z dnia 13.01.2020 r.
PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.
PB-08/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
PB-10/KJ-7.2 wyd. 02 z dnia 24.04.2025 r.
PB-11/KJ-7.2 wyd. 02 z dnia 07.01.2026 r.
PN ISO 6439:1994
PN-77/C-04584
PN-82/C-04576/08
PN-C-04554-1:1999 zał. A
PN-EN 13342:2002
PN-EN 15216:2022-03
PN-EN 15934:2013-02
PN-EN 15935:2022-01
PN-EN 1899-2:2002
PN-EN 1899-2:2002 z wył. pkt. 7.2
PN-EN 25663:2001
PN-EN 25813:1997
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10304-4:2022-08
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11206:2013-07
PN-EN ISO 11731-2:2017-08
PN-EN ISO 11731:2017-08 /Ap1:2019:12
PN-EN ISO 11885:2009
PN-EN ISO 12846:2012+Ap1:2016-07
PN-EN ISO 14189:2016-10
PN-EN ISO 15586:2005
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6
PN-EN ISO 5667-13:2011
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C
PN-EN ISO 7893-2:2018-04
PN-EN ISO 7899-2:2004
PN-EN ISO 7980:2002
PN-EN ISO 8467:2001
PN-EN ISO 9308-1/A1:2017
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6439:1994
PN-ISO 7150-1:2002
PN-ISO 8288:2002 Metoda A
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9964-1:1994+Ap1:2009
PN-ISO 9964-2:1994+Ak:1997
PN-ISO 9965:2001
PN-Z-19005:2018-10