🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. PL

PCA AB 814 • Gliwice, Poland • 98 methods

Water & wastewaterEnvironmentMicrobiologyMaterials & polymers

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o. is a laboratory accredited by PCA under number AB 814 (Gliwice, Poland). Its accreditation scope covers 98 test methods in the following areas: Water & wastewater, Environment, Microbiology, Materials & polymers. Test objects include: Water, water intended for human consumption, wastewater, Water, water intended for human consumption, Odpady O) kod: 19 08 05, Wastewater. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Flame atomic absorption spectrometry (FAAS).

At a glance

  • Accreditation number: PCA AB 814
  • Methods in scope: 98
  • Types of test objects: 9
  • Techniques used: 21
  • City: Gliwice, Poland
Accreditation number
AB 814
Accreditation body
PCA
Address
ul. Rybnicka 47, 44-100 Gliwice, DZIAŁ LABORATORIUM, ul. T. Edisona 16
City
Gliwice, Poland

What this laboratory tests (9)

Analytical techniques used (21)

Laboratory locations

Certificate information

Issue date
02.06.2026
Issue no.
20

Accreditation scope — test methods (98)

No. Test object Methodology / Parameters Technique Reference document
Dział Laboratorium
1 Water intended for human consumption Sampling for chemical and physical testing
Temperature Range (2,0 – 50,0) °C
PN-ISO 5667-5:2017-10 | PN-77/C-04584
2 Water Sampling for chemical and physical testing
Temperature of water/collected water sample Range (2,0 – 70,0) °C
PN-ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6 | PN-77/C-04584
3 Water Kjeldahl nitrogen concentration
Range (2,0 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
4 Water Total nitrogen concentration (calculated) PB-05/KJ-7.2 wydanie 01 z dnia 13.01.2020 r.
5 Water Phenol index
Range (0,010 – 5,0) mg/l
Spectrophotometric method PN ISO 6439:1994
6 Water Ammonium nitrogen concentration
Range (2,0 – 1000) mg/l Ammonium ion concentration Range (2,6 – 1280) mg/l
Titrimetric method PN-ISO 5664:2002
7 Water Element concentration
Cadmium (0,010 – 0,5) mg/l Lead (0,0050 – 0,5) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
8 Water, water intended for human consumption Calcium concentration
Range (0,05 – 25) mmol/l Range (2 – 1000) mg/l
Titrimetric method PN-ISO 6058:1999
9 Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-1:1999 zał. A
10 Water, water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (0,05 – 100) mmol/l Range (5,0 – 10000) mg/l CaCO 3
Titrimetric method PN-ISO 6059:1999
11 Water, water intended for human consumption Turbidity
Range (0,20 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
12 Water, water intended for human consumption Colour
Range (5,0 – 80) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 Metoda C
13 Water, water intended for human consumption Calcium concentration
Range (3,0 – 1000) mg/l
Flame atomic absorption spectrometry (FAAS) PN-EN ISO 7980:2002
14 Water, water intended for human consumption Magnesium concentration
Range (1,0 – 150) mg/l
Flame atomic absorption spectrometry (FAAS) PN-EN ISO 7980:2002
15 Water, water intended for human consumption Mercury concentration
Range (0,00020 – 0,0020) mg/l
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07
16 Water, water intended for human consumption Ammonium ion concentration
Range (0,064 – 2,6) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
17 Water, water intended for human consumption Permanganate index
Range (0,50 – 10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
18 Water, water intended for human consumption Bromate concentration
Range (1,0 – 100) μg/l
Ion chromatography with spectrophotometric detection (IC-UV/Vis) PN-EN ISO 11206:2013-07
19 Water, water intended for human consumption Chlorate concentration
Range (0,050 – 10) mg/l Chlorite concentration Range (0,050 – 10) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-4:2022-08
20 Water, water intended for human consumption Sum of chlorates and chlorites (calculated) PN-EN ISO 10304-4:2022-08
21 Water, water intended for human consumption Nitrate concentration
Range (0,18 – 200) mg/l
Spectrophotometric method PN-82/C-04576/08
22 Water, water intended for human consumption Nitrite concentration
Range (0,030 – 30) mg/l
Spectrophotometric method PN-EN 26777:1999
23 Water, water intended for human consumption Anion concentrations:
nitrates (1,0 – 500) mg/l nitrites (0,050 – 50) mg/l fluorides (0,050 – 20) mg/l chlorides (1,00 – 5000) mg/l sulfates (1,00 – 5000) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
24 Water, water intended for human consumption Element concentration
Barium (0,010 – 2,5) mg/l Boron (0,010 – 2,5) mg/l Total chromium (0,0050 – 0,5) mg/l Zinc (0,020 – 2,0) mg/l Phosphorus (0,10 – 50) mg/l Aluminium (0,0100 – 5) mg/l Magnesium (1,0 – 200) mg/l Manganese (0,0020 – 1,5) mg/l Molybdenum (0,010 – 0,5) mg/l Copper (0,0050 – 2,5) mg/l Nickel (0,0050– 0,50) mg/l Potassium (1,0 – 200) mg/l Sodium (1,00– 250) mg/l Vanadium (0,010 – 0,5) mg/l Calcium (1,0 – 200) mg/l Iron (0,00200 – 20) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
25 Water, water intended for human consumption Free chlorine concentration
Range (0,02 – 3,0) mg/l
Regulated area: Badania wykonywane poza siedzibą Laboratorium
Spectrophotometric method PN-EN ISO 7893-2:2018-04
26 Water, water intended for human consumption Total chlorine concentration
Range (0,02 – 3,0) mg/l
Regulated area: Badania wykonywane poza siedzibą Laboratorium
Spectrophotometric method PN-EN ISO 7893-2:2018-04
27 Water, water intended for human consumption Chloramine concentration (calculated) PN-EN ISO 7893-2:2018-04
28 Water, water intended for human consumption Ozone concentration
Range (0,01 – 0,65) mg/l
Regulated area: Badania wykonywane poza siedzibą Laboratorium
Spectrophotometric method PB-11/KJ-7.2 wyd. 02 z dnia 07.01.2026 r.
29 Water, wastewater, rainwater, snowmelt water Mineral oil index
Range (0,010 – 100) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
30 Rainwater, snowmelt water Sampling for chemical and physical testing
Temperature Range (2,0 – 50,0)°C
Manual method PN-ISO 5667-10:2021-11 | PN-77/C-04584
31 Rainwater, snowmelt water Total suspended solids (TSS)
Range (2,0 – 5000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
32 Wastewater Sampling for chemical and physical testing
Temperature Range (2,0 – 50,0)°C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
33 Wastewater Nitrate nitrogen concentration
Range (0,04 – 50) mg/l
Spectrophotometric method PN-82/C-04576/08
34 Wastewater Element concentration
Antimony (0,0050 – 0,50) mg/l Selenium (0,0050 – 0,50) mg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
35 Wastewater Element concentration
Barium (0,010 – 2,5) mg/l Boron (0,010 – 2,5) mg/l Total chromium (0,0050 – 0,5) mg/l Zinc (0,020 – 2,0) mg/l Phosphorus (0,10 – 500) mg/l Aluminium (0,010 – 5,0) mg/l Cadmium (0,010 – 0,5) mg/l Magnesium (1,0 – 200) mg/l Manganese (0,0020 – 1,5) mg/l Molybdenum (0,010 – 0,5) mg/l Copper (0,0050 – 2,5) mg/l Nickel (0,0050 – 0,5) mg/l Lead (0,0050 – 0,5) mg/l Potassium (1,0 – 200) mg/l Sodium (1,0 – 250) mg/l Vanadium (0,010 – 0,5) mg/l Calcium (1,0 – 200) mg/l Iron (0,0020 – 20) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
36 Wastewater Ammonium nitrogen concentration
Range (2,0 – 1000) mg/l
Titrimetric method PN-ISO 5664:2002
37 Wastewater Nitrite nitrogen concentration
Range (0,01 – 10) mg/l
Spectrophotometric method PN-EN 26777:1999
38 Wastewater Anion concentrations:
nitrate nitrogen (0,30 – 100) mg/l nitrite nitrogen (0,015 – 15) mg/l fluorides (0,050 – 20) mg/l chlorides (1,0 – 5000) mg/l sulfates (1,0 – 5000) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
39 Wastewater Phosphate concentration
Range (0,15 – 100) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
40 Wastewater Total phosphorus concentration
Range (0,050 – 35,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
41 Wastewater Kjeldahl nitrogen concentration
Range (2,0 – 1000) mg/l
Titrimetric method PN-EN 25663:2001
42 Wastewater Total nitrogen concentration (calculated) PB-05/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
43 Wastewater Mercury concentration
Range (0,00020 – 0,10) mg/l
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07
44 Wastewater Ammonium nitrogen concentration
Range (0,050 – 2,5) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
45 Wastewater Phenol index
Range (0,010 – 5,0) mg/l
Spectrophotometric method PN-ISO 6439:1994
46 Water, water intended for human consumption, wastewater Electrical conductivity
Range (10 – 20000) μS/cm
Conductometric method PN-EN 27888:1999
47 Water, water intended for human consumption, wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
48 Water, water intended for human consumption, wastewater Potassium concentration
Range (0,5 – 200) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-2:1994+Ak:1997
49 Water, water intended for human consumption, wastewater Chloride concentration
Range (5,0 – 4000) mg/l
Titrimetric method PN-ISO 9297:1994
50 Water, water intended for human consumption, wastewater Metal concentrations
Arsenic (0,0030 – 0,10) mg/l Manganese (0,0015 – 1,5) mg/l Iron (0,00150 – 3,0) mg/l Cadmium (0,00040 – 0,10) mg/l Cobalt (0,0050 – 2,0) mg/l Copper (0,0015 – 2,5) mg/l Lead (0,0015 – 0,50) mg/l Total chromium (0,0020 – 0,50) mg/l Nickel (0,0050 – 0,50) mg/l Silver (0,0010 – 0,10) mg/l Vanadium (0,0020 – 0,10) mg/l
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
51 Water, water intended for human consumption, wastewater Sodium concentration
Range (2,00 – 250) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-1:1994+Ap1:2009
52 Water, water intended for human consumption, wastewater Zinc concentration
Range (0,1 – 2,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 Metoda A
53 Water, water intended for human consumption, wastewater Copper concentration
Range (0,050 – 2,5) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 Metoda A
54 Water, water intended for human consumption, wastewater Sulfate concentration
Range (10 – 5000) mg/l
Gravimetric method PN-ISO 9280:2002
55 Water, water intended for human consumption, wastewater Antimony concentration
Range (0,0010 – 0,10) mg/l
Hydride generation atomic absorption spectrometry (HGAAS) PB-10/KJ-7.2 wyd. 02 z dnia 24.04.2025 r.
56 Water, water intended for human consumption, wastewater Selenium concentration
Range (0,0010 – 0,10) mg/l
Hydride generation atomic absorption spectrometry (HGAAS) PN-ISO 9965:2001
57 Water, water intended for human consumption, wastewater Total alkalinity
Range (0,4 – 100) mmol/l
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
58 Water, water intended for human consumption, wastewater Carbonate hardness (calculated) PN-EN ISO 9963-1:2001+Ap1:2004
59 Water, water intended for human consumption, wastewater Bicarbonate concentration (calculated) PN-EN ISO 9963-1:2001+Ap1:2004
60 Water, water intended for human consumption, wastewater Total suspended solids (TSS)
Range (2,0 – 5000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
61 Water, water intended for human consumption, wastewater Chemical oxygen demand
COD-Cr Range (15,0 – 4000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
62 Water, water intended for human consumption, wastewater Biochemical oxygen demand
BOD5 Range (0,50 – 6,0) mg/l O2
Titrimetric method PN-EN 1899-2:2002
63 Water, water intended for human consumption, wastewater Biochemical oxygen demand
BOD5 Range (3 – 6000) mg/l O2
Titrimetric method PN-EN ISO 5815-1:2019-12
64 Water, water intended for human consumption, wastewater Dissolved oxygen concentration
Range (0,5 – 15,0) mg/l O2
Titrimetric method PN-EN 25813:1997
65 Water, water intended for human consumption, wastewater Total dissolved solids (TDS)
Range (10,0 – 5000) mg/l
Gravimetric method PN-EN 15216:2022-03
66 Water, water intended for human consumption, wastewater Mineral dissolved solids
Range (10,0 – 5000) mg/l
Gravimetric method PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.
67 Water, water intended for human consumption, wastewater Volatile dissolved solids (calculated) PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.
68 Water, water intended for human consumption, wastewater Dry residue
Range (10,0 – 5000) mg/l
Gravimetric method PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.
69 Water, water intended for human consumption, wastewater Residue on ignition
Range (10,0 – 5000) mg/l
Gravimetric method PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.
70 Water, water intended for human consumption, wastewater Loss on ignition (calculated) PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.
71 Water, water intended for human consumption, wastewater Biochemical oxygen demand
BOD5 Range (3 – 6000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
72 Water, water intended for human consumption, wastewater Biochemical oxygen demand
BOD5 Range (0,50 – 6,0) mg/l O2
Optical method PN-EN 1899-2:2002 z wył. pkt. 7.2 | ISO 17289:2014
73 Water, Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6
74 Water, Water intended for human consumption Ogólna liczba mikroorganizmów w temp. (36 ± 2) ºC po 48h Plate method (pour plate) PN-EN ISO 6222:2004
75 Water, Water intended for human consumption Ogólna liczba mikroorganizmów w temp. (22 ± 2) ºC po 72h Plate method (pour plate) PN-EN ISO 6222:2004
76 Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017
77 Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017
78 Water, Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
79 Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
80 Water, Water intended for human consumption Count of bacteria of the genus Legionella
Matrix A Procedure 5 (medium A – BCYE) Procedure 7 (medium C – GVPC) Range od 1 jtk/ 100 ml Range od 1 jtk/ 1000 ml
Membrane filtration method PN-EN ISO 11731-2:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019:12
81 Water, Water intended for human consumption Clostridium perfingens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10
82 Odpady O) kod: 19 08 05 Sampling for chemical, physical and microbiological testing
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
PN-EN ISO 5667-13:2011
83 Odpady O) kod: 19 08 05 pH
Range 2,0 – 12,0
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Potentiometric method PN-EN ISO 10390:2022-09
84 Odpady O) kod: 19 08 05 Residue on ignition
Range (0,5 – 99,5) %
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Gravimetric method PN-EN 15935:2022-01
85 Odpady O) kod: 19 08 05 Loss on ignition (calculated)
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
PN-EN 15935:2022-01
86 Odpady O) kod: 19 08 05 Dry residue
Range (0,5 – 99,5) %
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Gravimetric method PN-EN 15934:2013-02
87 Odpady O) kod: 19 08 05 Water content (calculated)
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
PN-EN 15934:2013-02
88 Odpady O) kod: 19 08 05 Kjeldahl nitrogen content
Range (0,5 – 10) %
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Titrimetric method PN-EN 13342:2002
89 Odpady O) kod: 19 08 05 Ammonium nitrogen content
Range (0,1 – 5,0) %
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Titrimetric method PB-08/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
90 Odpady O) kod: 19 08 05 Zinc content
Range (100 – 2000) mg/kg
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
91 Odpady O) kod: 19 08 05 Copper content
Range (50 – 2000) mg/kg
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Flame atomic absorption spectrometry (FAAS) PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
92 Odpady O) kod: 19 08 05 Metal content
Total chromium (2,0 – 500) mg/kg Nickel (7,0 – 500) mg/kg Cadmium (0,40 – 100) mg/kg Copper (1,5 – 2000) mg/kg Lead (3,0 – 500) mg/kg
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Electrothermal atomization atomic absorption spectrometry (ETAAS) PN-EN ISO 15586:2005
93 Odpady O) kod: 19 08 05 Calcium content
Range (500 – 200000) mg/kg
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Flame atomic absorption spectrometry (FAAS) PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
94 Odpady O) kod: 19 08 05 Magnesium content
Range (50 – 100000) mg/kg
Regulated area: Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Flame atomic absorption spectrometry (FAAS) PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
95 Odpady O) kod: 19 08 05 Mercury content
Range (0,50 – 5,0) mg/kg
Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
96 Odpady O) kod: 19 08 05 Element content
Total chromium (5 – 500) mg/kg Zinc (20 – 2000) mg/kg Total phosphorus (1000 – 50000) mg/kg Cadmium (10 – 500) mg/kg Magnesium (1000 – 100000) mg/kg Copper (5 – 2000) mg/kg Nickel (10 – 500) mg/kg Lead (5 – 500) mg/kg Calcium (1000 – 200000) mg/kg
Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
97 Odpady O) kod: 19 08 05 Obecność bakterii z rodzaju Salmonella w 10 g
Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Culture method with biochemical confirmation PB-01/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
98 Odpady O) kod: 19 08 05 Presence and number of viable eggs of intestinal parasites ATT (Ascaris sp., Trichuris sp., Toxocara sp.)
Range od 1 w kg s.m.
Regulated area: Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.
Metoda flotacyjno-sedymentacyjno-mikroskopowa PN-Z-19005:2018-10

Reference standards (67)

I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
ISO 17289:2014
PB-01/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
PB-05/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
PB-05/KJ-7.2 wydanie 01 z dnia 13.01.2020 r.
PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.
PB-08/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.
PB-10/KJ-7.2 wyd. 02 z dnia 24.04.2025 r.
PB-11/KJ-7.2 wyd. 02 z dnia 07.01.2026 r.
PN ISO 6439:1994
PN-77/C-04584
PN-82/C-04576/08
PN-C-04554-1:1999 zał. A
PN-EN 13342:2002
PN-EN 15216:2022-03
PN-EN 15934:2013-02
PN-EN 15935:2022-01
PN-EN 1899-2:2002
PN-EN 1899-2:2002 z wył. pkt. 7.2
PN-EN 25663:2001
PN-EN 25813:1997
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10304-4:2022-08
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11206:2013-07
PN-EN ISO 11731-2:2017-08
PN-EN ISO 11731:2017-08 /Ap1:2019:12
PN-EN ISO 11885:2009
PN-EN ISO 12846:2012+Ap1:2016-07
PN-EN ISO 14189:2016-10
PN-EN ISO 15586:2005
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6
PN-EN ISO 5667-13:2011
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C
PN-EN ISO 7893-2:2018-04
PN-EN ISO 7899-2:2004
PN-EN ISO 7980:2002
PN-EN ISO 8467:2001
PN-EN ISO 9308-1/A1:2017
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001+Ap1:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6439:1994
PN-ISO 7150-1:2002
PN-ISO 8288:2002 Metoda A
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9964-1:1994+Ap1:2009
PN-ISO 9964-2:1994+Ak:1997
PN-ISO 9965:2001
PN-Z-19005:2018-10

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20814