{"lab":{"_id":"69ad52a3de79e566650fb418","accr_number":"AB 814","country":"PL","accr_body":"PCA","address":"ul. Rybnicka 47, 44-100 Gliwice, DZIAŁ LABORATORIUM, ul. T. Edisona 16","categories":["water","environment","microbiology","materials"],"city":"Gliwice","imported_at":"2026-03-08T10:42:43.265Z","methods_count":98,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_814.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji sp. z o.o. ul. rybnicka 47, 44-100 gliwice, dział laboratorium, ul. t. edisona 16 water other pharma electronics materials microbiology automotive environment","status":"active","updated_at":"2026-03-08T14:51:42.099Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:13:32.748Z","location":{"type":"Point","coordinates":[18.6714,50.2945]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20814,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów, odpadów","en":"Chemical tests and sampling of water, drinking water, sewage, sediments, waste"},{"codes":"N/28/P; N/29/P; N/30/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów, odpadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, sediments, waste"},{"codes":"K/28/P; K/29/P; K/32/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi, osadów, odpadów","en":"Microbiological tests and sampling of water, drinking water, sediments, waste"}],"issue":{"no":"20","date":"02.06.2026"},"parse_date":"2026-08-18T01:13:32.748Z","parse_source":"agent-claude-code","map_coord":[50.281855,18.662797],"map_geo":"nominatim-street","lab_locations":[{"name":"DZIAŁ LABORATORIUM","address":"ul. T. Edisona 16","city":"Gliwice","postal":"44-102"}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/f2f14a2774674c27a626cb17c7b2c503/AB%20814.pdf","has_en":true,"category_counts":{"water":82,"environment":17,"microbiology":6,"materials":5,"petro":1},"category_scores":{"water":60.58,"environment":2.6,"microbiology":0.32,"materials":0.23,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a83b1bcaf14b9c0e7b20804","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(2,0 – 50,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0) °C","reference":"PN-ISO 5667-5:2017-10 | PN-77/C-04584","norm_bases":["PN-ISO 5667-5:2017-10","PN-77/C-04584"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0) °C PN-ISO 5667-5:2017-10 | PN-77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0) °C PN-ISO 5667-5:2017-10 | PN-77/C-04584","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(2,0 – 50,0) °C"}],"search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature Range PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(2,0 – 50,0) °C"}],"search_zh":"生活饮用水 化学与物理检测用样品采集 温度 范围 PN-ISO 5667-5:2017-10 | PN-77/C-04584","test_object_zh":"生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b20805","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura wody/pobranej próbki wody"},{"name":"Zakres","range":"(2,0 – 70,0) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura wody/pobranej próbki wody\nZakres (2,0 – 70,0) °C","reference":"PN-ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6 | PN-77/C-04584","norm_bases":["PN-ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6","PN-77/C-04584"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura wody/pobranej próbki wody\nZakres (2,0 – 70,0) °C PN-ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura wody/pobranej probki wody\nZakres (2,0 – 70,0) °C PN-ISO 5667-6:2016-12 z wylaczeniem p. 7.3, 7.5, 7.6 | PN-77/C-04584","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of water/collected water sample"},{"name":"Range","range":"(2,0 – 70,0) °C"}],"search_en":"Water Sampling for chemical and physical testing Temperature of water/collected water sample Range PN-ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6 | PN-77/C-04584","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"水/所采水样的温度"},{"name":"范围","range":"(2,0 – 70,0) °C"}],"search_zh":"水 化学与物理检测用样品采集 水/所采水样的温度 范围 PN-ISO 5667-6:2016-12 z wyłączeniem p. 7.3, 7.5, 7.6 | PN-77/C-04584","test_object_zh":"水"},{"_id":"6a83b1bcaf14b9c0e7b20806","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu Kjeldahla\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda Stezenie azotu Kjeldahla\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a83b1bcaf14b9c0e7b20807","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-05/KJ-7.2 wydanie 01 z dnia 13.01.2020 r.","norm_bases":["PB-05/KJ-7.2 wydanie 01 z dnia 13.01.2020 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu ogólnego (z obliczeń) PB-05/KJ-7.2 wydanie 01 z dnia 13.01.2020 r. Woda Stezenie azotu ogolnego (z obliczen) PB-05/KJ-7.2 wydanie 01 z dnia 13.01.2020 r.","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water Total nitrogen concentration (calculated) PB-05/KJ-7.2 wydanie 01 z dnia 13.01.2020 r.","test_object_en":"Water","methodology_zh":"总氮浓度（计算值）","search_zh":"水 总氮浓度（计算值） PB-05/KJ-7.2 wydanie 01 z dnia 13.01.2020 r.","test_object_zh":"水"},{"_id":"6a83b1bcaf14b9c0e7b20808","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,010 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN ISO 6439:1994","norm_bases":["PN ISO 6439:1994"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Indeks fenolowy\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN ISO 6439:1994 Woda Indeks fenolowy\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN ISO 6439:1994","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,010 – 5,0) mg/l"}],"search_en":"Water Phenol index Spectrophotometric method Range PN ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,010 – 5,0) mg/l"}],"search_zh":"水 酚指数 分光光度法 范围 PN ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"酚指数"},{"_id":"6a83b1bcaf14b9c0e7b20809","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(2,6 – 1280) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (2,0 – 1000) mg/l\nStężenie jonu amonowego\nZakres (2,6 – 1280) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu amonowego\nZakres:\nZakres (2,0 – 1000) mg/l\nStężenie jonu amonowego\nZakres (2,6 – 1280) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda Stezenie azotu amonowego\nZakres:\nZakres (2,0 – 1000) mg/l\nStezenie jonu amonowego\nZakres (2,6 – 1280) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(2,6 – 1280) mg/l"}],"search_en":"Water Ammonium nitrogen concentration Titrimetric method Range Ammonium ion concentration Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(2,6 – 1280) mg/l"}],"search_zh":"水 氨氮浓度 滴定法 范围 铵离子浓度 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a83b1bcaf14b9c0e7b2080a","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie pierwiastków","parameters":[{"name":"Kadm","range":"(0,010 – 0,5) mg/l"},{"name":"Ołów","range":"(0,0050 – 0,5) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nKadm (0,010 – 0,5) mg/l\nOłów (0,0050 – 0,5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie pierwiastków\nZakres:\nKadm (0,010 – 0,5) mg/l\nOłów (0,0050 – 0,5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie pierwiastkow\nZakres:\nKadm (0,010 – 0,5) mg/l\nOlow (0,0050 – 0,5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"Cadmium","range":"(0,010 – 0,5) mg/l"},{"name":"Lead","range":"(0,0050 – 0,5) mg/l"}],"search_en":"Water Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Cadmium Lead PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water","methodology_zh":"元素浓度","parameters_zh":[{"name":"镉","range":"(0,010 – 0,5) mg/l"},{"name":"铅","range":"(0,0050 – 0,5) mg/l"}],"search_zh":"水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 镉 铅 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水"},{"_id":"6a83b1bcaf14b9c0e7b2080b","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(0,05 – 25) mmol/l"},{"name":"Zakres","range":"(2 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres:\nZakres (0,05 – 25) mmol/l\nZakres (2 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia\nZakres:\nZakres (0,05 – 25) mmol/l\nZakres (2 – 1000) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, woda do spozycia przez ludzi Stezenie wapnia\nZakres:\nZakres (0,05 – 25) mmol/l\nZakres (2 – 1000) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(0,05 – 25) mmol/l"},{"name":"Range","range":"(2 – 1000) mg/l"}],"search_en":"Water, water intended for human consumption Calcium concentration Titrimetric method Range Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,05 – 25) mmol/l"},{"name":"范围","range":"(2 – 1000) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a83b1bcaf14b9c0e7b2080c","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-1:1999 zał. A","norm_bases":["PN-C-04554-1:1999 zał. A"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-1:1999 zał. A Woda, woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-1:1999 zal. A","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration (calculated)","search_en":"Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-1:1999 zał. A","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 镁浓度（计算值） PN-C-04554-1:1999 zał. A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a83b1bcaf14b9c0e7b2080d","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(0,05 – 100) mmol/l"},{"name":"Zakres","range":"(5,0 – 10000) mg/l CaCO 3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,05 – 100) mmol/l\nZakres (5,0 – 10000) mg/l CaCO 3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres:\nZakres (0,05 – 100) mmol/l\nZakres (5,0 – 10000) mg/l CaCO 3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres:\nZakres (0,05 – 100) mmol/l\nZakres (5,0 – 10000) mg/l CaCO 3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(0,05 – 100) mmol/l"},{"name":"Range","range":"(5,0 – 10000) mg/l CaCO 3"}],"search_en":"Water, water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(0,05 – 100) mmol/l"},{"name":"范围","range":"(5,0 – 10000) mg/l CaCO 3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 范围 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b2080e","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 100) NTU"}],"search_en":"Water, water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b2080f","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5,0 – 80) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5,0 – 80) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C","norm_bases":["PN-EN ISO 7887:2012 Metoda C"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (5,0 – 80) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C Woda, woda do spozycia przez ludzi Barwa\nZakres (5,0 – 80) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5,0 – 80) mg/l Pt"}],"search_en":"Water, water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 Metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5,0 – 80) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b20810","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(3,0 – 1000) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie wapnia\nZakres (3,0 – 1000) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002","norm_bases":["PN-EN ISO 7980:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia\nZakres (3,0 – 1000) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 Woda, woda do spozycia przez ludzi Stezenie wapnia\nZakres (3,0 – 1000) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(3,0 – 1000) mg/l"}],"search_en":"Water, water intended for human consumption Calcium concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN ISO 7980:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(3,0 – 1000) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN ISO 7980:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a83b1bcaf14b9c0e7b20811","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie magnezu","parameters":[{"name":"Zakres","range":"(1,0 – 150) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie magnezu\nZakres (1,0 – 150) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002","norm_bases":["PN-EN ISO 7980:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu\nZakres (1,0 – 150) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 Woda, woda do spozycia przez ludzi Stezenie magnezu\nZakres (1,0 – 150) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration","parameters_en":[{"name":"Range","range":"(1,0 – 150) mg/l"}],"search_en":"Water, water intended for human consumption Magnesium concentration Flame atomic absorption spectrometry (FAAS) Range PN-EN ISO 7980:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1,0 – 150) mg/l"}],"search_zh":"水、生活饮用水 镁浓度 火焰原子吸收光谱法（FAAS） 范围 PN-EN ISO 7980:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度"},{"_id":"6a83b1bcaf14b9c0e7b20812","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,00020 – 0,0020) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,00020 – 0,0020) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012+Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012+Ap1:2016-07"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie rtęci\nZakres (0,00020 – 0,0020) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07 Woda, woda do spozycia przez ludzi Stezenie rteci\nZakres (0,00020 – 0,0020) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,00020 – 0,0020) mg/l"}],"search_en":"Water, water intended for human consumption Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012+Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Water, water intended for human consumption","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,00020 – 0,0020) mg/l"}],"search_zh":"水、生活饮用水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012+Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b20813","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,064 – 2,6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,064 – 2,6) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,064 – 2,6) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,064 – 2,6) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,064 – 2,6) mg/l"}],"search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,064 – 2,6) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b20814","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 10) mg/l O2"}],"search_en":"Water, water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b20815","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie bromianów","parameters":[{"name":"Zakres","range":"(1,0 – 100) μg/l"}],"technique":"Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis)","techniques":["Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis)"],"computed":[],"activity":"Stężenie bromianów\nZakres (1,0 – 100) μg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis)","reference":"PN-EN ISO 11206:2013-07","norm_bases":["PN-EN ISO 11206:2013-07"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie bromianów\nZakres (1,0 – 100) μg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/Vis) PN-EN ISO 11206:2013-07 Woda, woda do spozycia przez ludzi Stezenie bromianow\nZakres (1,0 – 100) μg/l\nMetoda chromatografii jonowej z detekcja spektrofotometryczna (IC-UV/Vis) PN-EN ISO 11206:2013-07","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bromate concentration","parameters_en":[{"name":"Range","range":"(1,0 – 100) μg/l"}],"search_en":"Water, water intended for human consumption Bromate concentration Ion chromatography with spectrophotometric detection (IC-UV/Vis) Range PN-EN ISO 11206:2013-07","technique_en":"Ion chromatography with spectrophotometric detection (IC-UV/Vis)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1,0 – 100) μg/l"}],"search_zh":"水、生活饮用水 溴酸盐浓度 离子色谱-分光光度检测法（IC-UV/Vis） 范围 PN-EN ISO 11206:2013-07","test_object_zh":"水、生活饮用水","methodology_zh":"溴酸盐浓度","technique_zh":"离子色谱-分光光度检测法（IC-UV/Vis）"},{"_id":"6a83b1bcaf14b9c0e7b20816","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chloranów","parameters":[{"name":"Zakres","range":"(0,050 – 10) mg/l"},{"name":"Stężenie chlorynów"},{"name":"Zakres","range":"(0,050 – 10) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chloranów\nZakres:\nZakres (0,050 – 10) mg/l\nStężenie chlorynów\nZakres (0,050 – 10) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloranów\nZakres:\nZakres (0,050 – 10) mg/l\nStężenie chlorynów\nZakres (0,050 – 10) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda, woda do spozycia przez ludzi Stezenie chloranow\nZakres:\nZakres (0,050 – 10) mg/l\nStezenie chlorynow\nZakres (0,050 – 10) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorate concentration","parameters_en":[{"name":"Range","range":"(0,050 – 10) mg/l"},{"name":"Chlorite concentration"},{"name":"Range","range":"(0,050 – 10) mg/l"}],"search_en":"Water, water intended for human consumption Chlorate concentration Ion chromatography with conductometric detection (IC-CD) Range Chlorite concentration Range PN-EN ISO 10304-4:2022-08","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,050 – 10) mg/l"},{"name":"亚氯酸盐浓度"},{"name":"范围","range":"(0,050 – 10) mg/l"}],"search_zh":"水、生活饮用水 氯酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 亚氯酸盐浓度 范围 PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","methodology_zh":"氯酸盐浓度"},{"_id":"6a83b1bcaf14b9c0e7b20817","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Suma chloranów i chlorynów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma chloranów i chlorynów (z obliczeń)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Suma chloranów i chlorynów (z obliczeń) PN-EN ISO 10304-4:2022-08 Woda, woda do spozycia przez ludzi Suma chloranow i chlorynow (z obliczen) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of chlorates and chlorites (calculated)","search_en":"Water, water intended for human consumption Sum of chlorates and chlorites (calculated) PN-EN ISO 10304-4:2022-08","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 氯酸盐与亚氯酸盐总量（由计算得出） PN-EN ISO 10304-4:2022-08","test_object_zh":"水、生活饮用水","methodology_zh":"氯酸盐与亚氯酸盐总量（由计算得出）"},{"_id":"6a83b1bcaf14b9c0e7b20818","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,18 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,18 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,18 – 200) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,18 – 200) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,18 – 200) mg/l"}],"search_en":"Water, water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,18 – 200) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b20819","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,030 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,030 – 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,030 – 30) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,030 – 30) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,030 – 30) mg/l"}],"search_en":"Water, water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,030 – 30) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b2081a","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie anionów:","parameters":[{"name":"azotany","range":"(1,0 – 500) mg/l"},{"name":"azotyny","range":"(0,050 – 50) mg/l"},{"name":"fluorki","range":"(0,050 – 20) mg/l"},{"name":"chlorki","range":"(1,00 – 5000) mg/l"},{"name":"siarczany","range":"(1,00 – 5000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów:\nZakres:\nazotany (1,0 – 500) mg/l\nazotyny (0,050 – 50) mg/l\nfluorki (0,050 – 20) mg/l\nchlorki (1,00 – 5000) mg/l\nsiarczany (1,00 – 5000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie anionów:\nZakres:\nazotany (1,0 – 500) mg/l\nazotyny (0,050 – 50) mg/l\nfluorki (0,050 – 20) mg/l\nchlorki (1,00 – 5000) mg/l\nsiarczany (1,00 – 5000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, woda do spozycia przez ludzi Stezenie anionow:\nZakres:\nazotany (1,0 – 500) mg/l\nazotyny (0,050 – 50) mg/l\nfluorki (0,050 – 20) mg/l\nchlorki (1,00 – 5000) mg/l\nsiarczany (1,00 – 5000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations:","parameters_en":[{"name":"nitrates","range":"(1,0 – 500) mg/l"},{"name":"nitrites","range":"(0,050 – 50) mg/l"},{"name":"fluorides","range":"(0,050 – 20) mg/l"},{"name":"chlorides","range":"(1,00 – 5000) mg/l"},{"name":"sulfates","range":"(1,00 – 5000) mg/l"}],"search_en":"Water, water intended for human consumption Anion concentrations: Ion chromatography with conductometric detection (IC-CD) nitrates nitrites fluorides chlorides sulfates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water, water intended for human consumption","methodology_zh":"阴离子浓度：","search_zh":"水、生活饮用水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 硝酸盐 亚硝酸盐 氟化物 氯化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"硝酸盐","range":"(1,0 – 500) mg/l"},{"name":"亚硝酸盐","range":"(0,050 – 50) mg/l"},{"name":"氟化物","range":"(0,050 – 20) mg/l"},{"name":"氯化物","range":"(1,00 – 5000) mg/l"},{"name":"硫酸盐","range":"(1,00 – 5000) mg/l"}]},{"_id":"6a83b1bcaf14b9c0e7b2081b","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie pierwiastków","parameters":[{"name":"Bar","range":"(0,010 – 2,5) mg/l"},{"name":"Bor","range":"(0,010 – 2,5) mg/l"},{"name":"Chrom ogólny","range":"(0,0050 – 0,5) mg/l"},{"name":"Cynk","range":"(0,020 – 2,0) mg/l"},{"name":"Fosfor","range":"(0,10 – 50) mg/l"},{"name":"Glin","range":"(0,0100 – 5) mg/l"},{"name":"Magnez","range":"(1,0 – 200) mg/l"},{"name":"Mangan","range":"(0,0020 – 1,5) mg/l"},{"name":"Molibden","range":"(0,010 – 0,5) mg/l"},{"name":"Miedź","range":"(0,0050 – 2,5) mg/l"},{"name":"Nikiel","range":"(0,0050– 0,50) mg/l"},{"name":"Potas","range":"(1,0 – 200) mg/l"},{"name":"Sód","range":"(1,00– 250) mg/l"},{"name":"Wanad","range":"(0,010 – 0,5) mg/l"},{"name":"Wapń","range":"(1,0 – 200) mg/l"},{"name":"Żelazo","range":"(0,00200 – 20) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nBar (0,010 – 2,5) mg/l\nBor (0,010 – 2,5) mg/l\nChrom ogólny (0,0050 – 0,5) mg/l\nCynk (0,020 – 2,0) mg/l\nFosfor (0,10 – 50) mg/l\nGlin (0,0100 – 5) mg/l\nMagnez (1,0 – 200) mg/l\nMangan (0,0020 – 1,5) mg/l\nMolibden (0,010 – 0,5) mg/l\nMiedź (0,0050 – 2,5) mg/l\nNikiel (0,0050– 0,50) mg/l\nPotas (1,0 – 200) mg/l\nSód (1,00– 250) mg/l\nWanad (0,010 – 0,5) mg/l\nWapń (1,0 – 200) mg/l\nŻelazo (0,00200 – 20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\nBar (0,010 – 2,5) mg/l\nBor (0,010 – 2,5) mg/l\nChrom ogólny (0,0050 – 0,5) mg/l\nCynk (0,020 – 2,0) mg/l\nFosfor (0,10 – 50) mg/l\nGlin (0,0100 – 5) mg/l\nMagnez (1,0 – 200) mg/l\nMangan (0,0020 – 1,5) mg/l\nMolibden (0,010 – 0,5) mg/l\nMiedź (0,0050 – 2,5) mg/l\nNikiel (0,0050– 0,50) mg/l\nPotas (1,0 – 200) mg/l\nSód (1,00– 250) mg/l\nWanad (0,010 – 0,5) mg/l\nWapń (1,0 – 200) mg/l\nŻelazo (0,00200 – 20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\nBar (0,010 – 2,5) mg/l\nBor (0,010 – 2,5) mg/l\nChrom ogolny (0,0050 – 0,5) mg/l\nCynk (0,020 – 2,0) mg/l\nFosfor (0,10 – 50) mg/l\nGlin (0,0100 – 5) mg/l\nMagnez (1,0 – 200) mg/l\nMangan (0,0020 – 1,5) mg/l\nMolibden (0,010 – 0,5) mg/l\nMiedz (0,0050 – 2,5) mg/l\nNikiel (0,0050– 0,50) mg/l\nPotas (1,0 – 200) mg/l\nSod (1,00– 250) mg/l\nWanad (0,010 – 0,5) mg/l\nWapn (1,0 – 200) mg/l\nZelazo (0,00200 – 20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"Barium","range":"(0,010 – 2,5) mg/l"},{"name":"Boron","range":"(0,010 – 2,5) mg/l"},{"name":"Total chromium","range":"(0,0050 – 0,5) mg/l"},{"name":"Zinc","range":"(0,020 – 2,0) mg/l"},{"name":"Phosphorus","range":"(0,10 – 50) mg/l"},{"name":"Aluminium","range":"(0,0100 – 5) mg/l"},{"name":"Magnesium","range":"(1,0 – 200) mg/l"},{"name":"Manganese","range":"(0,0020 – 1,5) mg/l"},{"name":"Molybdenum","range":"(0,010 – 0,5) mg/l"},{"name":"Copper","range":"(0,0050 – 2,5) mg/l"},{"name":"Nickel","range":"(0,0050– 0,50) mg/l"},{"name":"Potassium","range":"(1,0 – 200) mg/l"},{"name":"Sodium","range":"(1,00– 250) mg/l"},{"name":"Vanadium","range":"(0,010 – 0,5) mg/l"},{"name":"Calcium","range":"(1,0 – 200) mg/l"},{"name":"Iron","range":"(0,00200 – 20) mg/l"}],"search_en":"Water, water intended for human consumption Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Barium Boron Total chromium Zinc Phosphorus Aluminium Magnesium Manganese Molybdenum Copper Nickel Potassium Sodium Vanadium Calcium Iron PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, water intended for human consumption","methodology_zh":"元素浓度","parameters_zh":[{"name":"钡","range":"(0,010 – 2,5) mg/l"},{"name":"硼","range":"(0,010 – 2,5) mg/l"},{"name":"总铬","range":"(0,0050 – 0,5) mg/l"},{"name":"锌","range":"(0,020 – 2,0) mg/l"},{"name":"磷","range":"(0,10 – 50) mg/l"},{"name":"铝","range":"(0,0100 – 5) mg/l"},{"name":"镁","range":"(1,0 – 200) mg/l"},{"name":"锰","range":"(0,0020 – 1,5) mg/l"},{"name":"钼","range":"(0,010 – 0,5) mg/l"},{"name":"铜","range":"(0,0050 – 2,5) mg/l"},{"name":"镍","range":"(0,0050– 0,50) mg/l"},{"name":"钾","range":"(1,0 – 200) mg/l"},{"name":"钠","range":"(1,00– 250) mg/l"},{"name":"钒","range":"(0,010 – 0,5) mg/l"},{"name":"钙","range":"(1,0 – 200) mg/l"},{"name":"铁","range":"(0,00200 – 20) mg/l"}],"search_zh":"水、生活饮用水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 钡 硼 总铬 锌 磷 铝 镁 锰 钼 铜 镍 钾 钠 钒 钙 铁 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b2081c","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,02 – 3,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,02 – 3,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7893-2:2018-04","norm_bases":["PN-EN ISO 7893-2:2018-04"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,02 – 3,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7893-2:2018-04 Woda, woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,02 – 3,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7893-2:2018-04","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,02 – 3,0) mg/l"}],"search_en":"Water, water intended for human consumption Free chlorine concentration Spectrophotometric method Range PN-EN ISO 7893-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 3,0) mg/l"}],"search_zh":"水、生活饮用水 游离氯浓度 分光光度法 范围 PN-EN ISO 7893-2:2018-04","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b2081d","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,02 – 3,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru ogólnego\nZakres (0,02 – 3,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7893-2:2018-04","norm_bases":["PN-EN ISO 7893-2:2018-04"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloru ogólnego\nZakres (0,02 – 3,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7893-2:2018-04 Woda, woda do spozycia przez ludzi Stezenie chloru ogolnego\nZakres (0,02 – 3,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7893-2:2018-04","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,02 – 3,0) mg/l"}],"search_en":"Water, water intended for human consumption Total chlorine concentration Spectrophotometric method Range PN-EN ISO 7893-2:2018-04","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,02 – 3,0) mg/l"}],"search_zh":"水、生活饮用水 总氯浓度 分光光度法 范围 PN-EN ISO 7893-2:2018-04","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"总氯浓度"},{"_id":"6a83b1bcaf14b9c0e7b2081e","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chloramin (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloramin (z obliczeń)","reference":"PN-EN ISO 7893-2:2018-04","norm_bases":["PN-EN ISO 7893-2:2018-04"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloramin (z obliczeń) PN-EN ISO 7893-2:2018-04 Woda, woda do spozycia przez ludzi Stezenie chloramin (z obliczen) PN-EN ISO 7893-2:2018-04","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloramine concentration (calculated)","search_en":"Water, water intended for human consumption Chloramine concentration (calculated) PN-EN ISO 7893-2:2018-04","test_object_en":"Water, water intended for human consumption","search_zh":"水、生活饮用水 氯胺浓度（由计算得出） PN-EN ISO 7893-2:2018-04","test_object_zh":"水、生活饮用水","methodology_zh":"氯胺浓度（由计算得出）"},{"_id":"6a83b1bcaf14b9c0e7b2081f","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie ozonu","parameters":[{"name":"Zakres","range":"(0,01 – 0,65) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ozonu\nZakres (0,01 – 0,65) mg/l\nMetoda spektrofotometryczna","reference":"PB-11/KJ-7.2 wyd. 02 z dnia 07.01.2026 r.","norm_bases":["PB-11/KJ-7.2 wyd. 02 z dnia 07.01.2026 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie ozonu\nZakres (0,01 – 0,65) mg/l\nMetoda spektrofotometryczna PB-11/KJ-7.2 wyd. 02 z dnia 07.01.2026 r. Woda, woda do spozycia przez ludzi Stezenie ozonu\nZakres (0,01 – 0,65) mg/l\nMetoda spektrofotometryczna PB-11/KJ-7.2 wyd. 02 z dnia 07.01.2026 r.","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ozone concentration","parameters_en":[{"name":"Range","range":"(0,01 – 0,65) mg/l"}],"search_en":"Water, water intended for human consumption Ozone concentration Spectrophotometric method Range PB-11/KJ-7.2 wyd. 02 z dnia 07.01.2026 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,01 – 0,65) mg/l"}],"search_zh":"水、生活饮用水 臭氧浓度 分光光度法 范围 PB-11/KJ-7.2 wyd. 02 z dnia 07.01.2026 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"臭氧浓度"},{"_id":"6a83b1bcaf14b9c0e7b20820","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, ścieki, wody opadowe, wody roztopowe","methodology":"Indeks oleju mineralnego","parameters":[{"name":"Zakres","range":"(0,010 – 100) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Indeks oleju mineralnego\nZakres (0,010 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki, wody opadowe, wody roztopowe Indeks oleju mineralnego\nZakres (0,010 – 100) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki, wody opadowe, wody roztopowe Indeks oleju mineralnego\nZakres (0,010 – 100) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index","parameters_en":[{"name":"Range","range":"(0,010 – 100) mg/l"}],"search_en":"Water, wastewater, rainwater, snowmelt water Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Water, wastewater, rainwater, snowmelt water","parameters_zh":[{"name":"范围","range":"(0,010 – 100) mg/l"}],"search_zh":"水、废水、雨水、融雪水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"矿物油指数","test_object_zh":"水、废水、雨水、融雪水"},{"_id":"6a83b1bcaf14b9c0e7b20821","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(2,0 – 50,0)°C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0)°C\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe, wody roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0)°C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Wody opadowe, wody roztopowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0)°C\nMetoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(2,0 – 50,0)°C"}],"search_en":"Rainwater, snowmelt water Sampling for chemical and physical testing Manual method Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method","test_object_en":"Rainwater, snowmelt water","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(2,0 – 50,0)°C"}],"search_zh":"雨水、融雪水 化学与物理检测用样品采集 手工法 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"雨水、融雪水","technique_zh":"手工法"},{"_id":"6a83b1bcaf14b9c0e7b20822","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Wody opadowe, wody roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe, wody roztopowe Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Wody opadowe, wody roztopowe Zawiesiny ogolne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 5000) mg/l"}],"search_en":"Rainwater, snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Rainwater, snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 5000) mg/l"}],"search_zh":"雨水、融雪水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"雨水、融雪水"},{"_id":"6a83b1bcaf14b9c0e7b20823","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura"},{"name":"Zakres","range":"(2,0 – 50,0)°C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0)°C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0)°C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura\nZakres (2,0 – 50,0)°C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature"},{"name":"Range","range":"(2,0 – 50,0)°C"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method Temperature Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"温度"},{"name":"范围","range":"(2,0 – 50,0)°C"}],"search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a83b1bcaf14b9c0e7b20824","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,04 – 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,04 – 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,04 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres (0,04 – 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,04 – 50) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 50) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83b1bcaf14b9c0e7b20825","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"Antymon","range":"(0,0050 – 0,50) mg/l"},{"name":"Selen","range":"(0,0050 – 0,50) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nAntymon (0,0050 – 0,50) mg/l\nSelen (0,0050 – 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie pierwiastków\nZakres:\nAntymon (0,0050 – 0,50) mg/l\nSelen (0,0050 – 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Scieki Stezenie pierwiastkow\nZakres:\nAntymon (0,0050 – 0,50) mg/l\nSelen (0,0050 – 0,50) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"Antimony","range":"(0,0050 – 0,50) mg/l"},{"name":"Selenium","range":"(0,0050 – 0,50) mg/l"}],"search_en":"Wastewater Element concentration Electrothermal atomization atomic absorption spectrometry (ETAAS) Antimony Selenium PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Wastewater","methodology_zh":"元素浓度","search_zh":"污水 元素浓度 电热原子化原子吸收光谱法（ETAAS） 锑 硒 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"污水","parameters_zh":[{"name":"锑","range":"(0,0050 – 0,50) mg/l"},{"name":"硒","range":"(0,0050 – 0,50) mg/l"}]},{"_id":"6a83b1bcaf14b9c0e7b20826","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie pierwiastków","parameters":[{"name":"Bar","range":"(0,010 – 2,5) mg/l"},{"name":"Bor","range":"(0,010 – 2,5) mg/l"},{"name":"Chrom ogólny","range":"(0,0050 – 0,5) mg/l"},{"name":"Cynk","range":"(0,020 – 2,0) mg/l"},{"name":"Fosfor","range":"(0,10 – 500) mg/l"},{"name":"Glin","range":"(0,010 – 5,0) mg/l"},{"name":"Kadm","range":"(0,010 – 0,5) mg/l"},{"name":"Magnez","range":"(1,0 – 200) mg/l"},{"name":"Mangan","range":"(0,0020 – 1,5) mg/l"},{"name":"Molibden","range":"(0,010 – 0,5) mg/l"},{"name":"Miedź","range":"(0,0050 – 2,5) mg/l"},{"name":"Nikiel","range":"(0,0050 – 0,5) mg/l"},{"name":"Ołów","range":"(0,0050 – 0,5) mg/l"},{"name":"Potas","range":"(1,0 – 200) mg/l"},{"name":"Sód","range":"(1,0 – 250) mg/l"},{"name":"Wanad","range":"(0,010 – 0,5) mg/l"},{"name":"Wapń","range":"(1,0 – 200) mg/l"},{"name":"Żelazo","range":"(0,0020 – 20) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie pierwiastków\nZakres:\nBar (0,010 – 2,5) mg/l\nBor (0,010 – 2,5) mg/l\nChrom ogólny (0,0050 – 0,5) mg/l\nCynk (0,020 – 2,0) mg/l\nFosfor (0,10 – 500) mg/l\nGlin (0,010 – 5,0) mg/l\nKadm (0,010 – 0,5) mg/l\nMagnez (1,0 – 200) mg/l\nMangan (0,0020 – 1,5) mg/l\nMolibden (0,010 – 0,5) mg/l\nMiedź (0,0050 – 2,5) mg/l\nNikiel (0,0050 – 0,5) mg/l\nOłów (0,0050 – 0,5) mg/l\nPotas (1,0 – 200) mg/l\nSód (1,0 – 250) mg/l\nWanad (0,010 – 0,5) mg/l\nWapń (1,0 – 200) mg/l\nŻelazo (0,0020 – 20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie pierwiastków\nZakres:\nBar (0,010 – 2,5) mg/l\nBor (0,010 – 2,5) mg/l\nChrom ogólny (0,0050 – 0,5) mg/l\nCynk (0,020 – 2,0) mg/l\nFosfor (0,10 – 500) mg/l\nGlin (0,010 – 5,0) mg/l\nKadm (0,010 – 0,5) mg/l\nMagnez (1,0 – 200) mg/l\nMangan (0,0020 – 1,5) mg/l\nMolibden (0,010 – 0,5) mg/l\nMiedź (0,0050 – 2,5) mg/l\nNikiel (0,0050 – 0,5) mg/l\nOłów (0,0050 – 0,5) mg/l\nPotas (1,0 – 200) mg/l\nSód (1,0 – 250) mg/l\nWanad (0,010 – 0,5) mg/l\nWapń (1,0 – 200) mg/l\nŻelazo (0,0020 – 20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie pierwiastkow\nZakres:\nBar (0,010 – 2,5) mg/l\nBor (0,010 – 2,5) mg/l\nChrom ogolny (0,0050 – 0,5) mg/l\nCynk (0,020 – 2,0) mg/l\nFosfor (0,10 – 500) mg/l\nGlin (0,010 – 5,0) mg/l\nKadm (0,010 – 0,5) mg/l\nMagnez (1,0 – 200) mg/l\nMangan (0,0020 – 1,5) mg/l\nMolibden (0,010 – 0,5) mg/l\nMiedz (0,0050 – 2,5) mg/l\nNikiel (0,0050 – 0,5) mg/l\nOlow (0,0050 – 0,5) mg/l\nPotas (1,0 – 200) mg/l\nSod (1,0 – 250) mg/l\nWanad (0,010 – 0,5) mg/l\nWapn (1,0 – 200) mg/l\nZelazo (0,0020 – 20) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element concentration","parameters_en":[{"name":"Barium","range":"(0,010 – 2,5) mg/l"},{"name":"Boron","range":"(0,010 – 2,5) mg/l"},{"name":"Total chromium","range":"(0,0050 – 0,5) mg/l"},{"name":"Zinc","range":"(0,020 – 2,0) mg/l"},{"name":"Phosphorus","range":"(0,10 – 500) mg/l"},{"name":"Aluminium","range":"(0,010 – 5,0) mg/l"},{"name":"Cadmium","range":"(0,010 – 0,5) mg/l"},{"name":"Magnesium","range":"(1,0 – 200) mg/l"},{"name":"Manganese","range":"(0,0020 – 1,5) mg/l"},{"name":"Molybdenum","range":"(0,010 – 0,5) mg/l"},{"name":"Copper","range":"(0,0050 – 2,5) mg/l"},{"name":"Nickel","range":"(0,0050 – 0,5) mg/l"},{"name":"Lead","range":"(0,0050 – 0,5) mg/l"},{"name":"Potassium","range":"(1,0 – 200) mg/l"},{"name":"Sodium","range":"(1,0 – 250) mg/l"},{"name":"Vanadium","range":"(0,010 – 0,5) mg/l"},{"name":"Calcium","range":"(1,0 – 200) mg/l"},{"name":"Iron","range":"(0,0020 – 20) mg/l"}],"search_en":"Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Barium Boron Total chromium Zinc Phosphorus Aluminium Cadmium Magnesium Manganese Molybdenum Copper Nickel Lead Potassium Sodium Vanadium Calcium Iron PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Wastewater","methodology_zh":"元素浓度","parameters_zh":[{"name":"钡","range":"(0,010 – 2,5) mg/l"},{"name":"硼","range":"(0,010 – 2,5) mg/l"},{"name":"总铬","range":"(0,0050 – 0,5) mg/l"},{"name":"锌","range":"(0,020 – 2,0) mg/l"},{"name":"磷","range":"(0,10 – 500) mg/l"},{"name":"铝","range":"(0,010 – 5,0) mg/l"},{"name":"镉","range":"(0,010 – 0,5) mg/l"},{"name":"镁","range":"(1,0 – 200) mg/l"},{"name":"锰","range":"(0,0020 – 1,5) mg/l"},{"name":"钼","range":"(0,010 – 0,5) mg/l"},{"name":"铜","range":"(0,0050 – 2,5) mg/l"},{"name":"镍","range":"(0,0050 – 0,5) mg/l"},{"name":"铅","range":"(0,0050 – 0,5) mg/l"},{"name":"钾","range":"(1,0 – 200) mg/l"},{"name":"钠","range":"(1,0 – 250) mg/l"},{"name":"钒","range":"(0,010 – 0,5) mg/l"},{"name":"钙","range":"(1,0 – 200) mg/l"},{"name":"铁","range":"(0,0020 – 20) mg/l"}],"search_zh":"污水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 钡 硼 总铬 锌 磷 铝 镉 镁 锰 钼 铜 镍 铅 钾 钠 钒 钙 铁 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污水"},{"_id":"6a83b1bcaf14b9c0e7b20827","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a83b1bcaf14b9c0e7b20828","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,01 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,01 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,01 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,01 – 10) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,01 – 10) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 10) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83b1bcaf14b9c0e7b20829","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie anionów:","parameters":[{"name":"azot azotanowy","range":"(0,30 – 100) mg/l"},{"name":"azot azotynowy","range":"(0,015 – 15) mg/l"},{"name":"fluorki","range":"(0,050 – 20) mg/l"},{"name":"chlorki","range":"(1,0 – 5000) mg/l"},{"name":"siarczany","range":"(1,0 – 5000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów:\nZakres:\nazot azotanowy (0,30 – 100) mg/l\nazot azotynowy (0,015 – 15) mg/l\nfluorki (0,050 – 20) mg/l\nchlorki (1,0 – 5000) mg/l\nsiarczany (1,0 – 5000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie anionów:\nZakres:\nazot azotanowy (0,30 – 100) mg/l\nazot azotynowy (0,015 – 15) mg/l\nfluorki (0,050 – 20) mg/l\nchlorki (1,0 – 5000) mg/l\nsiarczany (1,0 – 5000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Scieki Stezenie anionow:\nZakres:\nazot azotanowy (0,30 – 100) mg/l\nazot azotynowy (0,015 – 15) mg/l\nfluorki (0,050 – 20) mg/l\nchlorki (1,0 – 5000) mg/l\nsiarczany (1,0 – 5000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations:","parameters_en":[{"name":"nitrate nitrogen","range":"(0,30 – 100) mg/l"},{"name":"nitrite nitrogen","range":"(0,015 – 15) mg/l"},{"name":"fluorides","range":"(0,050 – 20) mg/l"},{"name":"chlorides","range":"(1,0 – 5000) mg/l"},{"name":"sulfates","range":"(1,0 – 5000) mg/l"}],"search_en":"Wastewater Anion concentrations: Ion chromatography with conductometric detection (IC-CD) nitrate nitrogen nitrite nitrogen fluorides chlorides sulfates PN-EN ISO 10304-1:2009+AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Wastewater","methodology_zh":"阴离子浓度：","search_zh":"污水 阴离子浓度： 离子色谱-电导检测法（IC-CD） 硝酸盐氮 亚硝酸盐氮 氟化物 氯化物 硫酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"污水","parameters_zh":[{"name":"硝酸盐氮","range":"(0,30 – 100) mg/l"},{"name":"亚硝酸盐氮","range":"(0,015 – 15) mg/l"},{"name":"氟化物","range":"(0,050 – 20) mg/l"},{"name":"氯化物","range":"(1,0 – 5000) mg/l"},{"name":"硫酸盐","range":"(1,0 – 5000) mg/l"}]},{"_id":"6a83b1bcaf14b9c0e7b2082a","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,15 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,15 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforanów\nZakres (0,15 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforanow\nZakres (0,15 – 100) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,15 – 100) mg/l"}],"search_en":"Wastewater Phosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,15 – 100) mg/l"}],"search_zh":"污水 磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"磷酸盐浓度"},{"_id":"6a83b1bcaf14b9c0e7b2082b","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,050 – 35,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050 – 35,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,050 – 35,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,050 – 35,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,050 – 35,0) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 35,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83b1bcaf14b9c0e7b2082c","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a83b1bcaf14b9c0e7b2082d","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB-05/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","norm_bases":["PB-05/KJ-7.2 wyd. 01 z dnia 13.01.2020 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PB-05/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. Scieki Stezenie azotu ogolnego (z obliczen) PB-05/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater Total nitrogen concentration (calculated) PB-05/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","test_object_en":"Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PB-05/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","test_object_zh":"污水"},{"_id":"6a83b1bcaf14b9c0e7b2082e","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,00020 – 0,10) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,00020 – 0,10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012+Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012+Ap1:2016-07"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie rtęci\nZakres (0,00020 – 0,10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07 Scieki Stezenie rteci\nZakres (0,00020 – 0,10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,00020 – 0,10) mg/l"}],"search_en":"Wastewater Mercury concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012+Ap1:2016-07","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","test_object_en":"Wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,00020 – 0,10) mg/l"}],"search_zh":"污水 汞浓度 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012+Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"污水"},{"_id":"6a83b1bcaf14b9c0e7b2082f","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,050 – 2,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,050 – 2,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,050 – 2,5) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (0,050 – 2,5) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,050 – 2,5) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 2,5) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83b1bcaf14b9c0e7b20830","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,010 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994","norm_bases":["PN-ISO 6439:1994"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Indeks fenolowy\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 Scieki Indeks fenolowy\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,010 – 5,0) mg/l"}],"search_en":"Wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 5,0) mg/l"}],"search_zh":"污水 酚指数 分光光度法 范围 PN-ISO 6439:1994","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"酚指数"},{"_id":"6a83b1bcaf14b9c0e7b20831","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 – 20000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 – 20000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Przewodność elektryczna właściwa\nZakres (10 – 20000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi, scieki Przewodnosc elektryczna wlasciwa\nZakres (10 – 20000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 – 20000) μS/cm"}],"search_en":"Water, water intended for human consumption, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 – 20000) μS/cm"}],"search_zh":"水、生活饮用水、污水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b20832","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, water intended for human consumption, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、生活饮用水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b20833","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie potasu","parameters":[{"name":"Zakres","range":"(0,5 – 200) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie potasu\nZakres (0,5 – 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-2:1994+Ak:1997","norm_bases":["PN-ISO 9964-2:1994+Ak:1997"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie potasu\nZakres (0,5 – 200) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-2:1994+Ak:1997 Woda, woda do spozycia przez ludzi, scieki Stezenie potasu\nZakres (0,5 – 200) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-2:1994+Ak:1997","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Potassium concentration","parameters_en":[{"name":"Range","range":"(0,5 – 200) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Potassium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-2:1994+Ak:1997","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 200) mg/l"}],"search_zh":"水、生活饮用水、污水 钾浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-2:1994+Ak:1997","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水、污水","methodology_zh":"钾浓度"},{"_id":"6a83b1bcaf14b9c0e7b20834","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 4000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 4000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie chlorków\nZakres (5,0 – 4000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi, scieki Stezenie chlorkow\nZakres (5,0 – 4000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 4000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 4000) mg/l"}],"search_zh":"水、生活饮用水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b20835","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie metali","parameters":[{"name":"Arsen","range":"(0,0030 – 0,10) mg/l"},{"name":"Mangan","range":"(0,0015 – 1,5) mg/l"},{"name":"Żelazo","range":"(0,00150 – 3,0) mg/l"},{"name":"Kadm","range":"(0,00040 – 0,10) mg/l"},{"name":"Kobalt","range":"(0,0050 – 2,0) mg/l"},{"name":"Miedź","range":"(0,0015 – 2,5) mg/l"},{"name":"Ołów","range":"(0,0015 – 0,50) mg/l"},{"name":"Chrom ogólny","range":"(0,0020 – 0,50) mg/l"},{"name":"Nikiel","range":"(0,0050 – 0,50) mg/l"},{"name":"Srebro","range":"(0,0010 – 0,10) mg/l"},{"name":"Wanad","range":"(0,0020 – 0,10) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Stężenie metali\nZakres:\nArsen (0,0030 – 0,10) mg/l\nMangan (0,0015 – 1,5) mg/l\nŻelazo (0,00150 – 3,0) mg/l\nKadm (0,00040 – 0,10) mg/l\nKobalt (0,0050 – 2,0) mg/l\nMiedź (0,0015 – 2,5) mg/l\nOłów (0,0015 – 0,50) mg/l\nChrom ogólny (0,0020 – 0,50) mg/l\nNikiel (0,0050 – 0,50) mg/l\nSrebro (0,0010 – 0,10) mg/l\nWanad (0,0020 – 0,10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie metali\nZakres:\nArsen (0,0030 – 0,10) mg/l\nMangan (0,0015 – 1,5) mg/l\nŻelazo (0,00150 – 3,0) mg/l\nKadm (0,00040 – 0,10) mg/l\nKobalt (0,0050 – 2,0) mg/l\nMiedź (0,0015 – 2,5) mg/l\nOłów (0,0015 – 0,50) mg/l\nChrom ogólny (0,0020 – 0,50) mg/l\nNikiel (0,0050 – 0,50) mg/l\nSrebro (0,0010 – 0,10) mg/l\nWanad (0,0020 – 0,10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Woda, woda do spozycia przez ludzi, scieki Stezenie metali\nZakres:\nArsen (0,0030 – 0,10) mg/l\nMangan (0,0015 – 1,5) mg/l\nZelazo (0,00150 – 3,0) mg/l\nKadm (0,00040 – 0,10) mg/l\nKobalt (0,0050 – 2,0) mg/l\nMiedz (0,0015 – 2,5) mg/l\nOlow (0,0015 – 0,50) mg/l\nChrom ogolny (0,0020 – 0,50) mg/l\nNikiel (0,0050 – 0,50) mg/l\nSrebro (0,0010 – 0,10) mg/l\nWanad (0,0020 – 0,10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations","parameters_en":[{"name":"Arsenic","range":"(0,0030 – 0,10) mg/l"},{"name":"Manganese","range":"(0,0015 – 1,5) mg/l"},{"name":"Iron","range":"(0,00150 – 3,0) mg/l"},{"name":"Cadmium","range":"(0,00040 – 0,10) mg/l"},{"name":"Cobalt","range":"(0,0050 – 2,0) mg/l"},{"name":"Copper","range":"(0,0015 – 2,5) mg/l"},{"name":"Lead","range":"(0,0015 – 0,50) mg/l"},{"name":"Total chromium","range":"(0,0020 – 0,50) mg/l"},{"name":"Nickel","range":"(0,0050 – 0,50) mg/l"},{"name":"Silver","range":"(0,0010 – 0,10) mg/l"},{"name":"Vanadium","range":"(0,0020 – 0,10) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Metal concentrations Electrothermal atomization atomic absorption spectrometry (ETAAS) Arsenic Manganese Iron Cadmium Cobalt Copper Lead Total chromium Nickel Silver Vanadium PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"金属浓度","parameters_zh":[{"name":"砷","range":"(0,0030 – 0,10) mg/l"},{"name":"锰","range":"(0,0015 – 1,5) mg/l"},{"name":"铁","range":"(0,00150 – 3,0) mg/l"},{"name":"镉","range":"(0,00040 – 0,10) mg/l"},{"name":"钴","range":"(0,0050 – 2,0) mg/l"},{"name":"铜","range":"(0,0015 – 2,5) mg/l"},{"name":"铅","range":"(0,0015 – 0,50) mg/l"},{"name":"总铬","range":"(0,0020 – 0,50) mg/l"},{"name":"镍","range":"(0,0050 – 0,50) mg/l"},{"name":"银","range":"(0,0010 – 0,10) mg/l"},{"name":"钒","range":"(0,0020 – 0,10) mg/l"}],"search_zh":"水、生活饮用水、污水 金属浓度 电热原子化原子吸收光谱法（ETAAS） 砷 锰 铁 镉 钴 铜 铅 总铬 镍 银 钒 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b20836","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie sodu","parameters":[{"name":"Zakres","range":"(2,00 – 250) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie sodu\nZakres (2,00 – 250) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1:1994+Ap1:2009","norm_bases":["PN-ISO 9964-1:1994+Ap1:2009"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie sodu\nZakres (2,00 – 250) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+Ap1:2009 Woda, woda do spozycia przez ludzi, scieki Stezenie sodu\nZakres (2,00 – 250) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+Ap1:2009","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium concentration","parameters_en":[{"name":"Range","range":"(2,00 – 250) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Sodium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-1:1994+Ap1:2009","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(2,00 – 250) mg/l"}],"search_zh":"水、生活饮用水、污水 钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-1:1994+Ap1:2009","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水、污水","methodology_zh":"钠浓度"},{"_id":"6a83b1bcaf14b9c0e7b20837","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie cynku","parameters":[{"name":"Zakres","range":"(0,1 – 2,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie cynku\nZakres (0,1 – 2,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 Metoda A","norm_bases":["PN-ISO 8288:2002 Metoda A"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie cynku\nZakres (0,1 – 2,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A Woda, woda do spozycia przez ludzi, scieki Stezenie cynku\nZakres (0,1 – 2,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Zinc concentration","parameters_en":[{"name":"Range","range":"(0,1 – 2,0) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Zinc concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 Metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,1 – 2,0) mg/l"}],"search_zh":"水、生活饮用水、污水 锌浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 Metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水、污水","methodology_zh":"锌浓度"},{"_id":"6a83b1bcaf14b9c0e7b20838","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie miedzi","parameters":[{"name":"Zakres","range":"(0,050 – 2,5) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi\nZakres (0,050 – 2,5) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 Metoda A","norm_bases":["PN-ISO 8288:2002 Metoda A"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie miedzi\nZakres (0,050 – 2,5) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A Woda, woda do spozycia przez ludzi, scieki Stezenie miedzi\nZakres (0,050 – 2,5) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper concentration","parameters_en":[{"name":"Range","range":"(0,050 – 2,5) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Copper concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 Metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,050 – 2,5) mg/l"}],"search_zh":"水、生活饮用水、污水 铜浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 Metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、生活饮用水、污水","methodology_zh":"铜浓度"},{"_id":"6a83b1bcaf14b9c0e7b20839","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, woda do spozycia przez ludzi, scieki Stezenie siarczanow\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 5000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"}],"search_zh":"水、生活饮用水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b2083a","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie antymonu","parameters":[{"name":"Zakres","range":"(0,0010 – 0,10) mg/l"}],"technique":"Metoda atomowej spektrometrii absorpcyjnej z generowaniem wodorków (HGAAS)","techniques":["Metoda atomowej spektrometrii absorpcyjnej z generowaniem wodorków (HGAAS)"],"computed":[],"activity":"Stężenie antymonu\nZakres (0,0010 – 0,10) mg/l\nMetoda atomowej spektrometrii absorpcyjnej z generowaniem wodorków (HGAAS)","reference":"PB-10/KJ-7.2 wyd. 02 z dnia 24.04.2025 r.","norm_bases":["PB-10/KJ-7.2 wyd. 02 z dnia 24.04.2025 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie antymonu\nZakres (0,0010 – 0,10) mg/l\nMetoda atomowej spektrometrii absorpcyjnej z generowaniem wodorków (HGAAS) PB-10/KJ-7.2 wyd. 02 z dnia 24.04.2025 r. Woda, woda do spozycia przez ludzi, scieki Stezenie antymonu\nZakres (0,0010 – 0,10) mg/l\nMetoda atomowej spektrometrii absorpcyjnej z generowaniem wodorkow (HGAAS) PB-10/KJ-7.2 wyd. 02 z dnia 24.04.2025 r.","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Antimony concentration","parameters_en":[{"name":"Range","range":"(0,0010 – 0,10) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Antimony concentration Hydride generation atomic absorption spectrometry (HGAAS) Range PB-10/KJ-7.2 wyd. 02 z dnia 24.04.2025 r.","technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,0010 – 0,10) mg/l"}],"search_zh":"水、生活饮用水、污水 锑浓度 范围 PB-10/KJ-7.2 wyd. 02 z dnia 24.04.2025 r.","test_object_zh":"水、生活饮用水、污水","methodology_zh":"锑浓度"},{"_id":"6a83b1bcaf14b9c0e7b2083b","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie selenu","parameters":[{"name":"Zakres","range":"(0,0010 – 0,10) mg/l"}],"technique":"Metoda atomowej spektrometrii absorpcyjnej z generowaniem wodorków (HGAAS)","techniques":["Metoda atomowej spektrometrii absorpcyjnej z generowaniem wodorków (HGAAS)"],"computed":[],"activity":"Stężenie selenu\nZakres (0,0010 – 0,10) mg/l\nMetoda atomowej spektrometrii absorpcyjnej z generowaniem wodorków (HGAAS)","reference":"PN-ISO 9965:2001","norm_bases":["PN-ISO 9965:2001"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie selenu\nZakres (0,0010 – 0,10) mg/l\nMetoda atomowej spektrometrii absorpcyjnej z generowaniem wodorków (HGAAS) PN-ISO 9965:2001 Woda, woda do spozycia przez ludzi, scieki Stezenie selenu\nZakres (0,0010 – 0,10) mg/l\nMetoda atomowej spektrometrii absorpcyjnej z generowaniem wodorkow (HGAAS) PN-ISO 9965:2001","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Selenium concentration","parameters_en":[{"name":"Range","range":"(0,0010 – 0,10) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Selenium concentration Hydride generation atomic absorption spectrometry (HGAAS) Range PN-ISO 9965:2001","technique_en":"Hydride generation atomic absorption spectrometry (HGAAS)","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,0010 – 0,10) mg/l"}],"search_zh":"水、生活饮用水、污水 硒浓度 范围 PN-ISO 9965:2001","test_object_zh":"水、生活饮用水、污水","methodology_zh":"硒浓度"},{"_id":"6a83b1bcaf14b9c0e7b2083c","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,4 – 100) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres (0,4 – 100) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Zasadowość ogólna\nZakres (0,4 – 100) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda, woda do spozycia przez ludzi, scieki Zasadowosc ogolna\nZakres (0,4 – 100) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,4 – 100) mmol/l"}],"search_en":"Water, water intended for human consumption, wastewater Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001+Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,4 – 100) mmol/l"}],"search_zh":"水、生活饮用水、污水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"总碱度"},{"_id":"6a83b1bcaf14b9c0e7b2083d","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Twardość węglanowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Twardość węglanowa (z obliczeń)","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Twardość węglanowa (z obliczeń) PN-EN ISO 9963-1:2001+Ap1:2004 Woda, woda do spozycia przez ludzi, scieki Twardosc weglanowa (z obliczen) PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbonate hardness (calculated)","search_en":"Water, water intended for human consumption, wastewater Carbonate hardness (calculated) PN-EN ISO 9963-1:2001+Ap1:2004","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 碳酸盐硬度（由计算得出） PN-EN ISO 9963-1:2001+Ap1:2004","test_object_zh":"水、生活饮用水、污水","methodology_zh":"碳酸盐硬度（由计算得出）"},{"_id":"6a83b1bcaf14b9c0e7b2083e","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie wodorowęglanów (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie wodorowęglanów (z obliczeń)","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie wodorowęglanów (z obliczeń) PN-EN ISO 9963-1:2001+Ap1:2004 Woda, woda do spozycia przez ludzi, scieki Stezenie wodoroweglanow (z obliczen) PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bicarbonate concentration (calculated)","search_en":"Water, water intended for human consumption, wastewater Bicarbonate concentration (calculated) PN-EN ISO 9963-1:2001+Ap1:2004","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 碳酸氢盐浓度（由计算得出） PN-EN ISO 9963-1:2001+Ap1:2004","test_object_zh":"水、生活饮用水、污水","methodology_zh":"碳酸氢盐浓度（由计算得出）"},{"_id":"6a83b1bcaf14b9c0e7b2083f","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, woda do spozycia przez ludzi, scieki Zawiesiny ogolne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 5000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 5000) mg/l"}],"search_zh":"水、生活饮用水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b20840","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(15,0 – 4000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (15,0 – 4000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (15,0 – 4000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, woda do spozycia przez ludzi, scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (15,0 – 4000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(15,0 – 4000) mg/l O2"}],"search_en":"Water, water intended for human consumption, wastewater Chemical oxygen demand Spectrophotometric method COD-Cr Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(15,0 – 4000) mg/l O2"}],"search_zh":"水、生活饮用水、污水 化学需氧量（COD） 分光光度法 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a83b1bcaf14b9c0e7b20841","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda miareczkowa PN-EN 1899-2:2002 Woda, woda do spozycia przez ludzi, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda miareczkowa PN-EN 1899-2:2002","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Water, water intended for human consumption, wastewater Biochemical oxygen demand Titrimetric method BOD5 Range PN-EN 1899-2:2002","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、生活饮用水、污水 生化需氧量 滴定法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b20842","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda miareczkowa PN-EN ISO 5815-1:2019-12 Woda, woda do spozycia przez ludzi, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda miareczkowa PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, water intended for human consumption, wastewater Biochemical oxygen demand Titrimetric method BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、生活饮用水、污水 生化需氧量 滴定法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b20843","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(0,5 – 15,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN 25813:1997","norm_bases":["PN-EN 25813:1997"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2\nMetoda miareczkowa PN-EN 25813:1997 Woda, woda do spozycia przez ludzi, scieki Stezenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2\nMetoda miareczkowa PN-EN 25813:1997","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(0,5 – 15,0) mg/l O2"}],"search_en":"Water, water intended for human consumption, wastewater Dissolved oxygen concentration Titrimetric method Range PN-EN 25813:1997","technique_en":"Titrimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(0,5 – 15,0) mg/l O2"}],"search_zh":"水、生活饮用水、污水 溶解氧浓度 滴定法 范围 PN-EN 25813:1997","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"溶解氧浓度"},{"_id":"6a83b1bcaf14b9c0e7b20844","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Całkowite substancje rozpuszczone (TDS)","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (10,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Całkowite substancje rozpuszczone (TDS)\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, woda do spozycia przez ludzi, scieki Calkowite substancje rozpuszczone (TDS)\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total dissolved solids (TDS)","parameters_en":[{"name":"Range","range":"(10,0 – 5000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 5000) mg/l"}],"search_zh":"水、生活饮用水、污水 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"溶解性总固体（TDS）"},{"_id":"6a83b1bcaf14b9c0e7b20845","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Substancje rozpuszczone mineralne","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone mineralne\nZakres (10,0 – 5000) mg/l\nMetoda wagowa","reference":"PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","norm_bases":["PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Substancje rozpuszczone mineralne\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r. Woda, woda do spozycia przez ludzi, scieki Substancje rozpuszczone mineralne\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral dissolved solids","parameters_en":[{"name":"Range","range":"(10,0 – 5000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Mineral dissolved solids Gravimetric method Range PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 5000) mg/l"}],"search_zh":"水、生活饮用水、污水 重量法 范围 PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b20846","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Substancje rozpuszczone lotne (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Substancje rozpuszczone lotne (z obliczeń)","reference":"PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","norm_bases":["PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Substancje rozpuszczone lotne (z obliczeń) PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r. Woda, woda do spozycia przez ludzi, scieki Substancje rozpuszczone lotne (z obliczen) PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Volatile dissolved solids (calculated)","search_en":"Water, water intended for human consumption, wastewater Volatile dissolved solids (calculated) PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b20847","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (10,0 – 5000) mg/l\nMetoda wagowa","reference":"PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","norm_bases":["PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Sucha pozostałość\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r. Woda, woda do spozycia przez ludzi, scieki Sucha pozostalosc\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(10,0 – 5000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Dry residue Gravimetric method Range PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 5000) mg/l"}],"search_zh":"水、生活饮用水、污水 干残渣 重量法 范围 PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"干残渣"},{"_id":"6a83b1bcaf14b9c0e7b20848","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(10,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałość po prażeniu\nZakres (10,0 – 5000) mg/l\nMetoda wagowa","reference":"PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","norm_bases":["PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Pozostałość po prażeniu\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r. Woda, woda do spozycia przez ludzi, scieki Pozostalosc po prazeniu\nZakres (10,0 – 5000) mg/l\nMetoda wagowa PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Residue on ignition","parameters_en":[{"name":"Range","range":"(10,0 – 5000) mg/l"}],"search_en":"Water, water intended for human consumption, wastewater Residue on ignition Gravimetric method Range PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","technique_en":"Gravimetric method","test_object_en":"Water, water intended for human consumption, wastewater","parameters_zh":[{"name":"范围","range":"(10,0 – 5000) mg/l"}],"search_zh":"水、生活饮用水、污水 灼烧残渣 重量法 范围 PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","technique_zh":"重量法","test_object_zh":"水、生活饮用水、污水","methodology_zh":"灼烧残渣"},{"_id":"6a83b1bcaf14b9c0e7b20849","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Straty przy prażeniu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Straty przy prażeniu (z obliczeń)","reference":"PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","norm_bases":["PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Straty przy prażeniu (z obliczeń) PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r. Woda, woda do spozycia przez ludzi, scieki Straty przy prazeniu (z obliczen) PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (calculated)","search_en":"Water, water intended for human consumption, wastewater Loss on ignition (calculated) PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","test_object_en":"Water, water intended for human consumption, wastewater","search_zh":"水、生活饮用水、污水 PB-07/KJ-7.2 wyd. 02 z dnia 07.01.2025 r.","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b2084a","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 6000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Woda, woda do spozycia przez ludzi, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 6000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 6000) mg/l O2"}],"search_en":"Water, water intended for human consumption, wastewater Biochemical oxygen demand Optical method BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 6000) mg/l O2"}],"search_zh":"水、生活饮用水、污水 生化需氧量 光学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b2084b","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,50 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda optyczna","reference":"PN-EN 1899-2:2002 z wył. pkt. 7.2 | ISO 17289:2014","norm_bases":["PN-EN 1899-2:2002 z wył. pkt. 7.2","ISO 17289:2014"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wył. pkt. 7.2 | ISO 17289:2014 Woda, woda do spozycia przez ludzi, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,50 – 6,0) mg/l O2\nMetoda optyczna PN-EN 1899-2:2002 z wyl. pkt. 7.2 | ISO 17289:2014","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,50 – 6,0) mg/l O2"}],"search_en":"Water, water intended for human consumption, wastewater Biochemical oxygen demand Optical method BOD5 Range PN-EN 1899-2:2002 z wył. pkt. 7.2 | ISO 17289:2014","technique_en":"Optical method","test_object_en":"Water, water intended for human consumption, wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,50 – 6,0) mg/l O2"}],"search_zh":"水、生活饮用水、污水 生化需氧量 光学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002 z wył. pkt. 7.2 | ISO 17289:2014","technique_zh":"光学法","test_object_zh":"水、生活饮用水、污水"},{"_id":"6a83b1bcaf14b9c0e7b2084c","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6 Woda, Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wyl. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water, Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_en":"Water, Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wył. pkt. 4.4.3, 4.4.4, 4.4.5, 4.4.6","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b2084d","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. (36 ± 2) ºC po 48h","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. (36 ± 2) ºC po 48h\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. (36 ± 2) ºC po 48h\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. (36 ± 2) ºC po 48h\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, Water intended for human consumption Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b2084e","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. (22 ± 2) ºC po 72h","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. (22 ± 2) ºC po 72h\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. (22 ± 2) ºC po 72h\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. (22 ± 2) ºC po 72h\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, Water intended for human consumption Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b2084f","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1/A1:2017"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017","categories":["water","microbiology"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b20850","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1/A1:2017"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017","categories":["water","microbiology"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1/A1:2017","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b20851","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba enterokoków","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterococci count","search_en":"Water, Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"肠球菌计数","search_zh":"水、生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b20852","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b20853","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii z rodzaju Legionella","parameters":[{"name":"Matryca A"},{"name":"Procedura 5 (pożywka A – BCYE)"},{"name":"Procedura 7 (pożywka C – GVPC)"},{"name":"Zakres","range":"od 1 jtk/ 100 ml"},{"name":"Zakres","range":"od 1 jtk/ 1000 ml"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella\nZakres:\nMatryca A\nProcedura 5 (pożywka A – BCYE)\nProcedura 7 (pożywka C – GVPC)\nZakres od 1 jtk/ 100 ml\nZakres od 1 jtk/ 1000 ml\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731-2:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019:12","norm_bases":["PN-EN ISO 11731-2:2017-08","PN-EN ISO 11731:2017-08 /Ap1:2019:12"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nZakres:\nMatryca A\nProcedura 5 (pożywka A – BCYE)\nProcedura 7 (pożywka C – GVPC)\nZakres od 1 jtk/ 100 ml\nZakres od 1 jtk/ 1000 ml\nMetoda filtracji membranowej PN-EN ISO 11731-2:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019:12 Woda, Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nZakres:\nMatryca A\nProcedura 5 (pozywka A – BCYE)\nProcedura 7 (pozywka C – GVPC)\nZakres od 1 jtk/ 100 ml\nZakres od 1 jtk/ 1000 ml\nMetoda filtracji membranowej PN-EN ISO 11731-2:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019:12","categories":["microbiology","water"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of bacteria of the genus Legionella","parameters_en":[{"name":"Matrix A"},{"name":"Procedure 5 (medium A – BCYE)"},{"name":"Procedure 7 (medium C – GVPC)"},{"name":"Range","range":"od 1 jtk/ 100 ml"},{"name":"Range","range":"od 1 jtk/ 1000 ml"}],"search_en":"Water, Water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix A Procedure 5 (medium A – BCYE) Procedure 7 (medium C – GVPC) Range Range PN-EN ISO 11731-2:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019:12","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"Matryca A"},{"name":"Procedura 5 (pożywka A – BCYE)"},{"name":"Procedura 7 (pożywka C – GVPC)"},{"name":"范围","range":"od 1 jtk/ 100 ml"},{"name":"范围","range":"od 1 jtk/ 1000 ml"}],"search_zh":"水、生活饮用水 军团菌属细菌计数 膜过滤法 范围 范围 PN-EN ISO 11731-2:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019:12","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"军团菌属细菌计数"},{"_id":"6a83b1bcaf14b9c0e7b20854","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfingens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfingens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Clostridium perfingens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia przez ludzi Liczba Clostridium perfingens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfingens count (including spores)","search_en":"Water, Water intended for human consumption Clostridium perfingens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83b1bcaf14b9c0e7b20855","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych","reference":"PN-EN ISO 5667-13:2011","norm_bases":["PN-EN ISO 5667-13:2011"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Pobieranie próbek do badań chemicznych, fizycznych i mikrobiologicznych PN-EN ISO 5667-13:2011 Odpady O) kod: 19 08 05 Pobieranie probek do badan chemicznych, fizycznych i mikrobiologicznych PN-EN ISO 5667-13:2011","categories":["environment","microbiology"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical, physical and microbiological testing","search_en":"Sampling for chemical, physical and microbiological testing PN-EN ISO 5667-13:2011","methodology_zh":"用于化学、物理与微生物检验的采样","search_zh":"用于化学、物理与微生物检验的采样 PN-EN ISO 5667-13:2011"},{"_id":"6a83b1bcaf14b9c0e7b20856","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Odpady O) kod: 19 08 05 pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"pH Potentiometric method Range PN-EN ISO 10390:2022-09","technique_en":"Potentiometric method","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"pH 值 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法"},{"_id":"6a83b1bcaf14b9c0e7b20857","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Pozostałości po prażeniu","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Pozostałości po prażeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Pozostałości po prażeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady O) kod: 19 08 05 Pozostalosci po prazeniu\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Residue on ignition","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Residue on ignition Gravimetric method Range PN-EN 15935:2022-01","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法"},{"_id":"6a83b1bcaf14b9c0e7b20858","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Straty przy prażeniu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Straty przy prażeniu (z obliczeń)","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Straty przy prażeniu (z obliczeń) PN-EN 15935:2022-01 Odpady O) kod: 19 08 05 Straty przy prazeniu (z obliczen) PN-EN 15935:2022-01","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Loss on ignition (calculated)","search_en":"Loss on ignition (calculated) PN-EN 15935:2022-01"},{"_id":"6a83b1bcaf14b9c0e7b20859","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Sucha pozostałość","parameters":[{"name":"Zakres","range":"(0,5 – 99,5) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha pozostałość\nZakres (0,5 – 99,5) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Sucha pozostałość\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15934:2013-02 Odpady O) kod: 19 08 05 Sucha pozostalosc\nZakres (0,5 – 99,5) %\nMetoda wagowa PN-EN 15934:2013-02","categories":["environment"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dry residue","parameters_en":[{"name":"Range","range":"(0,5 – 99,5) %"}],"search_en":"Dry residue Gravimetric method Range PN-EN 15934:2013-02","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,5 – 99,5) %"}],"search_zh":"干残渣 重量法 范围 PN-EN 15934:2013-02","technique_zh":"重量法","methodology_zh":"干残渣"},{"_id":"6a83b1bcaf14b9c0e7b2085a","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość wody (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wody (z obliczeń)","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość wody (z obliczeń) PN-EN 15934:2013-02 Odpady O) kod: 19 08 05 Zawartosc wody (z obliczen) PN-EN 15934:2013-02","categories":["environment","water"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content (calculated)","search_en":"Water content (calculated) PN-EN 15934:2013-02","methodology_zh":"水分含量（计算值）","search_zh":"水分含量（计算值） PN-EN 15934:2013-02"},{"_id":"6a83b1bcaf14b9c0e7b2085b","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,5 – 10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,5 – 10) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość azotu Kjeldahla\nZakres (0,5 – 10) %\nMetoda miareczkowa PN-EN 13342:2002 Odpady O) kod: 19 08 05 Zawartosc azotu Kjeldahla\nZakres (0,5 – 10) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,5 – 10) %"}],"search_en":"Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,5 – 10) %"}],"search_zh":"凯氏氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","methodology_zh":"凯氏氮含量"},{"_id":"6a83b1bcaf14b9c0e7b2085c","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,1 – 5,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,1 – 5,0) %\nMetoda miareczkowa","reference":"PB-08/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","norm_bases":["PB-08/KJ-7.2 wyd. 01 z dnia 13.01.2020 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość azotu amonowego\nZakres (0,1 – 5,0) %\nMetoda miareczkowa PB-08/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. Odpady O) kod: 19 08 05 Zawartosc azotu amonowego\nZakres (0,1 – 5,0) %\nMetoda miareczkowa PB-08/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","categories":["environment"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,1 – 5,0) %"}],"search_en":"Ammonium nitrogen content Titrimetric method Range PB-08/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_en":"Titrimetric method","parameters_zh":[{"name":"范围","range":"(0,1 – 5,0) %"}],"search_zh":"氨氮含量 滴定法 范围 PB-08/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_zh":"滴定法","methodology_zh":"氨氮含量"},{"_id":"6a83b1bcaf14b9c0e7b2085d","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość cynku","parameters":[{"name":"Zakres","range":"(100 – 2000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość cynku\nZakres (100 – 2000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","norm_bases":["PN-ISO 8288:2002 Metoda A","I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość cynku\nZakres (100 – 2000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. Odpady O) kod: 19 08 05 Zawartosc cynku\nZakres (100 – 2000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Zinc content","parameters_en":[{"name":"Range","range":"(100 – 2000) mg/kg"}],"search_en":"Zinc content Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","parameters_zh":[{"name":"范围","range":"(100 – 2000) mg/kg"}],"search_zh":"锌含量 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"锌含量"},{"_id":"6a83b1bcaf14b9c0e7b2085e","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość miedzi","parameters":[{"name":"Zakres","range":"(50 – 2000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość miedzi\nZakres (50 – 2000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","norm_bases":["PN-ISO 8288:2002 Metoda A","I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość miedzi\nZakres (50 – 2000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. Odpady O) kod: 19 08 05 Zawartosc miedzi\nZakres (50 – 2000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Copper content","parameters_en":[{"name":"Range","range":"(50 – 2000) mg/kg"}],"search_en":"Copper content Flame atomic absorption spectrometry (FAAS) Range PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","parameters_zh":[{"name":"范围","range":"(50 – 2000) mg/kg"}],"search_zh":"铜含量 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 8288:2002 Metoda A | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"铜含量"},{"_id":"6a83b1bcaf14b9c0e7b2085f","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość metali","parameters":[{"name":"Chrom ogólny","range":"(2,0 – 500) mg/kg"},{"name":"Nikiel","range":"(7,0 – 500) mg/kg"},{"name":"Kadm","range":"(0,40 – 100) mg/kg"},{"name":"Miedź","range":"(1,5 – 2000) mg/kg"},{"name":"Ołów","range":"(3,0 – 500) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)"],"computed":[],"activity":"Zawartość metali\nZakres:\nChrom ogólny (2,0 – 500) mg/kg\nNikiel (7,0 – 500) mg/kg\nKadm (0,40 – 100) mg/kg\nMiedź (1,5 – 2000) mg/kg\nOłów (3,0 – 500) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS)","reference":"PN-EN ISO 15586:2005","norm_bases":["PN-EN ISO 15586:2005"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość metali\nZakres:\nChrom ogólny (2,0 – 500) mg/kg\nNikiel (7,0 – 500) mg/kg\nKadm (0,40 – 100) mg/kg\nMiedź (1,5 – 2000) mg/kg\nOłów (3,0 – 500) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ETAAS) PN-EN ISO 15586:2005 Odpady O) kod: 19 08 05 Zawartosc metali\nZakres:\nChrom ogolny (2,0 – 500) mg/kg\nNikiel (7,0 – 500) mg/kg\nKadm (0,40 – 100) mg/kg\nMiedz (1,5 – 2000) mg/kg\nOlow (3,0 – 500) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ETAAS) PN-EN ISO 15586:2005","categories":["materials","environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"Total chromium","range":"(2,0 – 500) mg/kg"},{"name":"Nickel","range":"(7,0 – 500) mg/kg"},{"name":"Cadmium","range":"(0,40 – 100) mg/kg"},{"name":"Copper","range":"(1,5 – 2000) mg/kg"},{"name":"Lead","range":"(3,0 – 500) mg/kg"}],"search_en":"Metal content Electrothermal atomization atomic absorption spectrometry (ETAAS) Total chromium Nickel Cadmium Copper Lead PN-EN ISO 15586:2005","technique_en":"Electrothermal atomization atomic absorption spectrometry (ETAAS)","parameters_zh":[{"name":"总铬","range":"(2,0 – 500) mg/kg"},{"name":"镍","range":"(7,0 – 500) mg/kg"},{"name":"镉","range":"(0,40 – 100) mg/kg"},{"name":"铜","range":"(1,5 – 2000) mg/kg"},{"name":"铅","range":"(3,0 – 500) mg/kg"}],"search_zh":"金属含量 电热原子化原子吸收光谱法（ETAAS） 总铬 镍 镉 铜 铅 PN-EN ISO 15586:2005","technique_zh":"电热原子化原子吸收光谱法（ETAAS）","methodology_zh":"金属含量"},{"_id":"6a83b1bcaf14b9c0e7b20860","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość wapnia","parameters":[{"name":"Zakres","range":"(500 – 200000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość wapnia\nZakres (500 – 200000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","norm_bases":["PN-EN ISO 7980:2002","I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość wapnia\nZakres (500 – 200000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. Odpady O) kod: 19 08 05 Zawartosc wapnia\nZakres (500 – 200000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium content","parameters_en":[{"name":"Range","range":"(500 – 200000) mg/kg"}],"search_en":"Calcium content Flame atomic absorption spectrometry (FAAS) Range PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","parameters_zh":[{"name":"范围","range":"(500 – 200000) mg/kg"}],"search_zh":"钙含量 火焰原子吸收光谱法（FAAS） 范围 PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"钙含量"},{"_id":"6a83b1bcaf14b9c0e7b20861","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość magnezu","parameters":[{"name":"Zakres","range":"(50 – 100000) mg/kg"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość magnezu\nZakres (50 – 100000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","norm_bases":["PN-EN ISO 7980:2002","I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania i pobieranie wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość magnezu\nZakres (50 – 100000) mg/kg\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. Odpady O) kod: 19 08 05 Zawartosc magnezu\nZakres (50 – 100000) mg/kg\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium content","parameters_en":[{"name":"Range","range":"(50 – 100000) mg/kg"}],"search_en":"Magnesium content Flame atomic absorption spectrometry (FAAS) Range PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","parameters_zh":[{"name":"范围","range":"(50 – 100000) mg/kg"}],"search_zh":"镁含量 火焰原子吸收光谱法（FAAS） 范围 PN-EN ISO 7980:2002 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","methodology_zh":"镁含量"},{"_id":"6a83b1bcaf14b9c0e7b20862","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość rtęci","parameters":[{"name":"Zakres","range":"(0,50 – 5,0) mg/kg"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"computed":[],"activity":"Zawartość rtęci\nZakres (0,50 – 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012+Ap1:2016-07 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","norm_bases":["PN-EN ISO 12846:2012+Ap1:2016-07","I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość rtęci\nZakres (0,50 – 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. Odpady O) kod: 19 08 05 Zawartosc rteci\nZakres (0,50 – 5,0) mg/kg\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012+Ap1:2016-07 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","parameters_en":[{"name":"Range","range":"(0,50 – 5,0) mg/kg"}],"search_en":"Mercury content Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012+Ap1:2016-07 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","methodology_zh":"汞含量","parameters_zh":[{"name":"范围","range":"(0,50 – 5,0) mg/kg"}],"search_zh":"汞含量 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012+Ap1:2016-07 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）"},{"_id":"6a83b1bcaf14b9c0e7b20863","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Zawartość pierwiastków","parameters":[{"name":"Chrom ogólny","range":"(5 – 500) mg/kg"},{"name":"Cynk","range":"(20 – 2000) mg/kg"},{"name":"Fosfor ogólny","range":"(1000 – 50000) mg/kg"},{"name":"Kadm","range":"(10 – 500) mg/kg"},{"name":"Magnez","range":"(1000 – 100000) mg/kg"},{"name":"Miedź","range":"(5 – 2000) mg/kg"},{"name":"Nikiel","range":"(10 – 500) mg/kg"},{"name":"Ołów","range":"(5 – 500) mg/kg"},{"name":"Wapń","range":"(1000 – 200000) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość pierwiastków\nZakres:\nChrom ogólny (5 – 500) mg/kg\nCynk (20 – 2000) mg/kg\nFosfor ogólny (1000 – 50000) mg/kg\nKadm (10 – 500) mg/kg\nMagnez (1000 – 100000) mg/kg\nMiedź (5 – 2000) mg/kg\nNikiel (10 – 500) mg/kg\nOłów (5 – 500) mg/kg\nWapń (1000 – 200000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","norm_bases":["PN-EN ISO 11885:2009","I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Zawartość pierwiastków\nZakres:\nChrom ogólny (5 – 500) mg/kg\nCynk (20 – 2000) mg/kg\nFosfor ogólny (1000 – 50000) mg/kg\nKadm (10 – 500) mg/kg\nMagnez (1000 – 100000) mg/kg\nMiedź (5 – 2000) mg/kg\nNikiel (10 – 500) mg/kg\nOłów (5 – 500) mg/kg\nWapń (1000 – 200000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. Odpady O) kod: 19 08 05 Zawartosc pierwiastkow\nZakres:\nChrom ogolny (5 – 500) mg/kg\nCynk (20 – 2000) mg/kg\nFosfor ogolny (1000 – 50000) mg/kg\nKadm (10 – 500) mg/kg\nMagnez (1000 – 100000) mg/kg\nMiedz (5 – 2000) mg/kg\nNikiel (10 – 500) mg/kg\nOlow (5 – 500) mg/kg\nWapn (1000 – 200000) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","categories":["environment","materials"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","parameters_en":[{"name":"Total chromium","range":"(5 – 500) mg/kg"},{"name":"Zinc","range":"(20 – 2000) mg/kg"},{"name":"Total phosphorus","range":"(1000 – 50000) mg/kg"},{"name":"Cadmium","range":"(10 – 500) mg/kg"},{"name":"Magnesium","range":"(1000 – 100000) mg/kg"},{"name":"Copper","range":"(5 – 2000) mg/kg"},{"name":"Nickel","range":"(10 – 500) mg/kg"},{"name":"Lead","range":"(5 – 500) mg/kg"},{"name":"Calcium","range":"(1000 – 200000) mg/kg"}],"search_en":"Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Total chromium Zinc Total phosphorus Cadmium Magnesium Copper Nickel Lead Calcium PN-EN ISO 11885:2009 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","methodology_zh":"元素含量","parameters_zh":[{"name":"总铬","range":"(5 – 500) mg/kg"},{"name":"锌","range":"(20 – 2000) mg/kg"},{"name":"Fosfor ogólny","range":"(1000 – 50000) mg/kg"},{"name":"镉","range":"(10 – 500) mg/kg"},{"name":"镁","range":"(1000 – 100000) mg/kg"},{"name":"铜","range":"(5 – 2000) mg/kg"},{"name":"镍","range":"(10 – 500) mg/kg"},{"name":"铅","range":"(5 – 500) mg/kg"},{"name":"钙","range":"(1000 – 200000) mg/kg"}],"search_zh":"元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 总铬 锌 镉 镁 铜 镍 铅 钙 PN-EN ISO 11885:2009 | I-02/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）"},{"_id":"6a83b1bcaf14b9c0e7b20864","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Obecność bakterii z rodzaju Salmonella w 10 g","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność bakterii z rodzaju Salmonella w 10 g\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PB-01/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","norm_bases":["PB-01/KJ-7.2 wyd. 01 z dnia 13.01.2020 r."],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Obecność bakterii z rodzaju Salmonella w 10 g\nMetoda hodowlana z potwierdzeniem biochemicznym PB-01/KJ-7.2 wyd. 01 z dnia 13.01.2020 r. Odpady O) kod: 19 08 05 Obecnosc bakterii z rodzaju Salmonella w 10 g\nMetoda hodowlana z potwierdzeniem biochemicznym PB-01/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","categories":["microbiology","environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Culture method with biochemical confirmation PB-01/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_en":"Culture method with biochemical confirmation","search_zh":"培养法结合生化确认 PB-01/KJ-7.2 wyd. 01 z dnia 13.01.2020 r.","technique_zh":"培养法结合生化确认"},{"_id":"6a83b1bcaf14b9c0e7b20865","lab_id":"69ad52a3de79e566650fb418","country":"PL","accr_number":"AB 814","accr_body":"PCA","test_object":"Odpady O) kod: 19 08 05","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych ATT (Ascaris sp., Trichuris sp., Toxocara sp.)","parameters":[{"name":"Zakres","range":"od 1 w kg s.m."}],"technique":"Metoda flotacyjno-sedymentacyjno-mikroskopowa","techniques":["Metoda flotacyjno-sedymentacyjno-mikroskopowa"],"computed":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych ATT (Ascaris sp., Trichuris sp., Toxocara sp.)\nZakres od 1 w kg s.m.\nMetoda flotacyjno-sedymentacyjno-mikroskopowa","reference":"PN-Z-19005:2018-10","norm_bases":["PN-Z-19005:2018-10"],"lab_section":"Dział Laboratorium","lab_address":null,"regulatory_area":"Badania wykonywane dla celów obszaru regulowanego objętego: - Rozporządzeniem Ministra Środowiska z dnia 6 lutego 2015 r. w sprawie stosowania komunalnych osadów ściekowych (Dz. U. 2015, poz. 257). o) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów.","flexible":false,"search_text":"Odpady O) kod: 19 08 05 Obecność i liczba żywych jaj pasożytów jelitowych ATT (Ascaris sp., Trichuris sp., Toxocara sp.)\nZakres od 1 w kg s.m.\nMetoda flotacyjno-sedymentacyjno-mikroskopowa PN-Z-19005:2018-10 Odpady O) kod: 19 08 05 Obecnosc i liczba zywych jaj pasozytow jelitowych ATT (Ascaris sp., Trichuris sp., Toxocara sp.)\nZakres od 1 w kg s.m.\nMetoda flotacyjno-sedymentacyjno-mikroskopowa PN-Z-19005:2018-10","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and number of viable eggs of intestinal parasites ATT (Ascaris sp., Trichuris sp., Toxocara sp.)","parameters_en":[{"name":"Range","range":"od 1 w kg s.m."}],"search_en":"Presence and number of viable eggs of intestinal parasites ATT (Ascaris sp., Trichuris sp., Toxocara sp.) Range PN-Z-19005:2018-10","parameters_zh":[{"name":"范围","range":"od 1 w kg s.m."}],"search_zh":"范围 PN-Z-19005:2018-10"}],"has_pdf":true}