🇵🇱 ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o. o. PL

PCA AB 813 • Tczew, Poland • 10 methods

Water & wastewater

ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o. o. is a laboratory accredited by PCA under number AB 813 (Tczew, Poland). Its accreditation scope covers 10 test methods in the following areas: Water & wastewater. Test objects include: Wastewater, Water, Water, Water intended for human consumption, Wastewater. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Manual method; Automatic method.

At a glance

  • Accreditation number: PCA AB 813
  • Methods in scope: 10
  • Types of test objects: 3
  • Techniques used: 5
  • City: Tczew, Poland
Accreditation number
AB 813
Accreditation body
PCA
Address
LABORATORIUM WODY I ŚCIEKÓW, ul. Czatkowska 8, 83-110 Tczew
City
Tczew, Poland

What this laboratory tests (3)

Analytical techniques used (5)

Laboratory locations

Accreditation scope — test methods (10)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, Water intended for human consumption pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
2 Water, Water intended for human consumption Iron concentration
Range (20 – 10 000) μg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
3 Water, Water intended for human consumption Manganese concentration
Range (15 – 700) μg/l
Spectrophotometric method Metoda Hach nr 8149 Ed. 10 12/2017
4 Water, Water intended for human consumption Ammonium ion concentration
Range (0,05 – 2,50) mg/l
Spectrophotometric method Metoda Hach LCK nr 304 Ed. 1 10/2019
5 Wastewater, Water Biochemical oxygen demand
BOD5 Range (3 – 2000) mg/l O2
Optical method PN-EN ISO 5815-1:2019-12
6 Wastewater, Water Chemical oxygen demand - COD-Cr
Range (15 – 10 000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
7 Wastewater, Water Total phosphorus concentration
Range (0,05 – 40) mg/l
Spectrophotometric method Metoda HACH LCK nr 348, LCK 349, LCK 350 Ed. 4 11/2020
8 Wastewater, Water Total nitrogen concentration
Range (1,0 – 200) mg/l
Spectrophotometric method Metoda HACH LCK nr 138, LCK 238, LCK 338 Ed. 4 04/2024
9 Wastewater, Water Total suspended solids (TSS)
Range (5,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
10 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11

Reference standards (10)

Metoda HACH LCK nr 138, LCK 238, LCK 338 Ed. 4 04/2024
Metoda HACH LCK nr 348, LCK 349, LCK 350 Ed. 4 11/2020
Metoda Hach LCK nr 304 Ed. 1 10/2019
Metoda Hach nr 8149 Ed. 10 12/2017
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5815-1:2019-12
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 6332:2001+Ap1:2016-06