{"lab":{"_id":"69ad52a3de79e566650fb416","accr_number":"AB 813","country":"PL","accr_body":"PCA","address":"LABORATORIUM WODY I ŚCIEKÓW, ul. Czatkowska 8, 83-110 Tczew","categories":["water"],"city":"Tczew","imported_at":"2026-03-08T10:42:43.265Z","methods_count":10,"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o. o.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_813.pdf"],"scope_summary":"","search_text":"zakład wodociągów i kanalizacji sp. z o. o. laboratorium wody i ścieków, ul. czatkowska 8, 83-110 tczew other water","status":"active","updated_at":"2026-03-08T14:51:41.996Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:11:45.682Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20813,podmiot.html","fields_of_testing":[{"codes":"C/28, C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"C/30/P","pl":"Badania chemiczne i pobieranie próbek ścieków","en":"Chemical tests and sampling of sewage"},{"codes":"N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek ścieków","en":"Tests of physical properties and sampling of sewage"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"}],"issue":{"no":"19","date":"26.06.2026"},"parse_date":"2026-08-13T08:11:45.682Z","parse_source":"agent-claude-code","map_coord":[54.117214,18.806358],"map_geo":"nominatim-street","lab_locations":[{"name":"ZAKŁAD WODOCIĄGÓW I KANALIZACJI Sp. z o. o.","address":"ul. Czatkowska 8","city":null,"postal":null},{"name":"LABORATORIUM WODY I ŚCIEKÓW","address":"ul. Czatkowska 8","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/c952a2005639e0798f4c7f73922453e1/AB%20813.pdf","has_en":true,"category_counts":{"water":10},"category_scores":{"water":10},"has_zh":true},"methods":[{"_id":"6a7d7c410636ba417e41c3b4","lab_id":"69ad52a3de79e566650fb416","country":"PL","accr_number":"AB 813","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d7c410636ba417e41c3b5","lab_id":"69ad52a3de79e566650fb416","country":"PL","accr_number":"AB 813","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(20 – 10 000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (20 – 10 000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza\nZakres (20 – 10 000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, Woda do spozycia przez ludzi Stezenie zelaza\nZakres (20 – 10 000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(20 – 10 000) μg/l"}],"search_en":"Water, Water intended for human consumption Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20 – 10 000) μg/l"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d7c410636ba417e41c3b6","lab_id":"69ad52a3de79e566650fb416","country":"PL","accr_number":"AB 813","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(15 – 700) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (15 – 700) μg/l\nMetoda spektrofotometryczna","reference":"Metoda Hach nr 8149 Ed. 10 12/2017","norm_bases":["Metoda Hach nr 8149 Ed. 10 12/2017"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (15 – 700) μg/l\nMetoda spektrofotometryczna Metoda Hach nr 8149 Ed. 10 12/2017 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (15 – 700) μg/l\nMetoda spektrofotometryczna Metoda Hach nr 8149 Ed. 10 12/2017","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(15 – 700) μg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Range Metoda Hach nr 8149 Ed. 10 12/2017","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(15 – 700) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 Metoda Hach nr 8149 Ed. 10 12/2017","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d7c410636ba417e41c3b7","lab_id":"69ad52a3de79e566650fb416","country":"PL","accr_number":"AB 813","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,05 – 2,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,05 – 2,50) mg/l\nMetoda spektrofotometryczna","reference":"Metoda Hach LCK nr 304 Ed. 1 10/2019","norm_bases":["Metoda Hach LCK nr 304 Ed. 1 10/2019"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,05 – 2,50) mg/l\nMetoda spektrofotometryczna Metoda Hach LCK nr 304 Ed. 1 10/2019 Woda, Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,05 – 2,50) mg/l\nMetoda spektrofotometryczna Metoda Hach LCK nr 304 Ed. 1 10/2019","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,50) mg/l"}],"search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range Metoda Hach LCK nr 304 Ed. 1 10/2019","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,50) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 Metoda Hach LCK nr 304 Ed. 1 10/2019","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a7d7c410636ba417e41c3b8","lab_id":"69ad52a3de79e566650fb416","country":"PL","accr_number":"AB 813","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 – 2000) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 2000) mg/l O2\nMetoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 2000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12 Scieki, Woda Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3 – 2000) mg/l O2\nMetoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 – 2000) mg/l O2"}],"search_en":"Wastewater, Water Biochemical oxygen demand Optical method BOD5 Range PN-EN ISO 5815-1:2019-12","technique_en":"Optical method","test_object_en":"Wastewater, Water","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 – 2000) mg/l O2"}],"search_zh":"废水、水 生化需氧量 光学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"光学法","test_object_zh":"废水、水"},{"_id":"6a7d7c410636ba417e41c3b9","lab_id":"69ad52a3de79e566650fb416","country":"PL","accr_number":"AB 813","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(15 – 10 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (15 – 10 000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (15 – 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki, Woda Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (15 – 10 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(15 – 10 000) mg/l O2"}],"search_en":"Wastewater, Water Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","parameters_zh":[{"name":"范围","range":"(15 – 10 000) mg/l O2"}],"search_zh":"废水、水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"废水、水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a7d7c410636ba417e41c3ba","lab_id":"69ad52a3de79e566650fb416","country":"PL","accr_number":"AB 813","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 40) mg/l\nMetoda spektrofotometryczna","reference":"Metoda HACH LCK nr 348, LCK 349, LCK 350 Ed. 4 11/2020","norm_bases":["Metoda HACH LCK nr 348, LCK 349, LCK 350 Ed. 4 11/2020"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie fosforu ogólnego\nZakres (0,05 – 40) mg/l\nMetoda spektrofotometryczna Metoda HACH LCK nr 348, LCK 349, LCK 350 Ed. 4 11/2020 Scieki, Woda Stezenie fosforu ogolnego\nZakres (0,05 – 40) mg/l\nMetoda spektrofotometryczna Metoda HACH LCK nr 348, LCK 349, LCK 350 Ed. 4 11/2020","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,05 – 40) mg/l"}],"search_en":"Wastewater, Water Total phosphorus concentration Spectrophotometric method Range Metoda HACH LCK nr 348, LCK 349, LCK 350 Ed. 4 11/2020","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 40) mg/l"}],"search_zh":"废水、水 总磷浓度 分光光度法 范围 Metoda HACH LCK nr 348, LCK 349, LCK 350 Ed. 4 11/2020","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a7d7c410636ba417e41c3bb","lab_id":"69ad52a3de79e566650fb416","country":"PL","accr_number":"AB 813","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 200) mg/l\nMetoda spektrofotometryczna","reference":"Metoda HACH LCK nr 138, LCK 238, LCK 338 Ed. 4 04/2024","norm_bases":["Metoda HACH LCK nr 138, LCK 238, LCK 338 Ed. 4 04/2024"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Stężenie azotu ogólnego\nZakres (1,0 – 200) mg/l\nMetoda spektrofotometryczna Metoda HACH LCK nr 138, LCK 238, LCK 338 Ed. 4 04/2024 Scieki, Woda Stezenie azotu ogolnego\nZakres (1,0 – 200) mg/l\nMetoda spektrofotometryczna Metoda HACH LCK nr 138, LCK 238, LCK 338 Ed. 4 04/2024","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 200) mg/l"}],"search_en":"Wastewater, Water Total nitrogen concentration Spectrophotometric method Range Metoda HACH LCK nr 138, LCK 238, LCK 338 Ed. 4 04/2024","technique_en":"Spectrophotometric method","test_object_en":"Wastewater, Water","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 200) mg/l"}],"search_zh":"废水、水 总氮浓度 分光光度法 范围 Metoda HACH LCK nr 138, LCK 238, LCK 338 Ed. 4 04/2024","technique_zh":"分光光度法","test_object_zh":"废水、水"},{"_id":"6a7d7c410636ba417e41c3bc","lab_id":"69ad52a3de79e566650fb416","country":"PL","accr_number":"AB 813","accr_body":"PCA","test_object":"Ścieki, Woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki, Woda Zawiesiny ogólne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki, Woda Zawiesiny ogolne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/l"}],"search_en":"Wastewater, Water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater, Water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/l"}],"search_zh":"废水、水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"废水、水"},{"_id":"6a7d7c410636ba417e41c3bd","lab_id":"69ad52a3de79e566650fb416","country":"PL","accr_number":"AB 813","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"}],"has_pdf":true}