🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI PL
Water & wastewaterMicrobiology
PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 808 (Głogów, Poland). Its accreditation scope covers 37 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Wastewater, Water intended for human consumption, Water, Water, Water intended for human consumption, Swimming pool water, Water intended for human consumption, Swimming pool water, Water. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.
At a glance
- Accreditation number: PCA AB 808
- Methods in scope: 37
- Types of test objects: 7
- Techniques used: 10
- City: Głogów, Poland
- Accreditation number
- AB 808
- Accreditation body
- PCA
- Address
- W GŁOGOWIE Sp. z o.o., ul. Łąkowa 52, 67-200 Głogów, DZIAŁ LABORATORIUM, ul. Krochmalna 3
- City
- Głogów, Poland
What this laboratory tests (7)
- Wastewater — 15 methods
- Water intended for human consumption, Water — 13 methods
- Water, Water intended for human consumption, Swimming pool water — 4 methods
- Water intended for human consumption, Swimming pool water, Water — 2 methods
- Swimming pool water — 1 method
- Water intended for human consumption — 1 method
- Water intended for human consumption, Swimming pool water — 1 method
Analytical techniques used (10)
- Spectrophotometric method — 12 methods
- Titrimetric method — 7 methods
- Membrane filtration method — 4 methods
- Conductometric method — 2 methods
- Plate method (pour plate) — 2 methods
- Potentiometric method — 2 methods
- Electrochemical method — 1 method
- Gravimetric method — 1 method
- Manual method; Automatic method; Potentiometric method — 1 method
- Nephelometric method — 1 method
Laboratory sections (2)
- LABORATORY DEPARTMENT; Water Laboratory — 22 methods
- LABORATORY DEPARTMENT; Wastewater Laboratory — 15 methods
Laboratory locations
- DZIAŁ LABORATORIUM — ul. Krochmalna 3
- Laboratorium Wody — ul. Wodna 1, 67-210 Serby
- Laboratorium Ścieków — ul. Krochmalna 3, 67-200 Głogów
- DZIAŁ LABORATORIUM; Laboratorium Wody —
- DZIAŁ LABORATORIUM; Laboratorium Ścieków —
Accreditation scope — test methods (37)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| LABORATORY DEPARTMENT; Water Laboratory | |||||
| 1 | Water intended for human consumption, Water | Nitrite concentration Range (0,020 – 0,50) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 2 | Water intended for human consumption, Water | Ammonium ion concentration Range (0,060 – 1,20) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 3 | Water intended for human consumption, Water | Calcium concentration Range (20 – 200) mg/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 4 | Water intended for human consumption, Water | Total iron concentration Range (0,030 – 20) mg/l |
Spectrophotometric method | PN-ISO 6332:2001 + Ap1:2016-06 | |
| 5 | Water intended for human consumption, Water | Total manganese concentration Range (0,030 – 3,0) mg/l |
Spectrophotometric method | P N - 9 2 / C - 0 4 5 9 0 /02 | |
| 6 | Water intended for human consumption, Water | Total content of calcium and magnesium (total hardness) Range (10,0 – 500) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 7 | Water intended for human consumption, Water | Chloride concentration Range (7,0 – 250) mg/l |
Titrimetric method | P N -ISO 9297:1994 | |
| 8 | Water intended for human consumption, Water | Electrical conductivity Range (290 – 2500) μS/cm |
Conductometric method | P N - E N 2 7 8 8 8 : 1 9 9 9 | |
| 9 | Water intended for human consumption, Water | pH Range 4,0 – 9,0 |
Potentiometric method | P N - E N I S O 1 0 5 2 3 : 2 0 1 2 | |
| 10 | Water intended for human consumption, Water | Colour Range (3 – 48) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06 | |
| 11 | Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 12 | Swimming pool water | Sampling for chemical and physical testing | Instrukcja ogólna IOL-27, wyd.01 z d n . 2 0 . 0 7 . 2 0 2 1 r. | ||
| 13 | Water, Water intended for human consumption, Swimming pool water | Turbidity Range (0,20 – 20) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 14 | Water, Water intended for human consumption, Swimming pool water | Nitrate concentration Range (0,88 – 65) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 15 | Water, Water intended for human consumption, Swimming pool water | Permanganate index (oxidisability) Range (0,50 – 9,0) mg/l |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 16 | Water intended for human consumption, Water | Enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 17 | Water intended for human consumption, Water | Total viable count at 22 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 18 | Water intended for human consumption, Water | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 19 | Water intended for human consumption, Swimming pool water, Water | Total viable count at 36 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 20 | Water intended for human consumption, Swimming pool water, Water | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 21 | Water intended for human consumption, Swimming pool water | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 22 | Water, Water intended for human consumption, Swimming pool water | Sampling for microbiological analyses | PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.4; 4.4.5; 4.4.6 | ||
| LABORATORY DEPARTMENT; Wastewater Laboratory | |||||
| 23 | Wastewater | Nitrate nitrogen concentration Range (0,20 – 54) mg /l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 24 | Wastewater | Nitrite nitrogen concentration Range (0,0125 – 5,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 25 | Wastewater | Ammonium nitrogen concentration Range (0,10 – 10) mg /l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 26 | Wastewater | Ammonium nitrogen concentration Range (1,0 – 200) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 27 | Wastewater | Kjeldahl nitrogen concentration Range (2,0 – 500) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 28 | Wastewater | Total nitrogen (calculated) | Procedura badawcza PB-13 wydanie 2 z dnia 06.03.2019 r. | ||
| 29 | Wastewater | Biochemical oxygen demand – BOD5 Range (3 – 3000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 30 | Wastewater | Total phosphorus concentration Range (0,040 – 30) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 | |
| 31 | Wastewater | Orthophosphate concentration Range (0,040 – 30) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt. 4. +Ap1:2010+Ap2:2010 | |
| 32 | Wastewater | Total suspended solids (TSS) Range (2,0 – 3000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 33 | Wastewater | Sampling for chemical and physical testing Temperature of the collected wastewater sample (in situ) Range (4,0 – 25,0) °C pH of the collected wastewater sample (in situ) Range 4,0 – 9,0 |
Manual method; Automatic method; Potentiometric method | PN-ISO 5667-10:2021-11 | PN -77/C-04584 | PN-EN ISO 10523:2012 | |
| 34 | Wastewater | Chloride concentration Range (5,0 – 150) mg/l |
Titrimetric method | P N -ISO 9297:1994 | |
| 35 | Wastewater | Chemical oxygen demand COD Range (10 – 4000 ) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 36 | Wastewater | Electrical conductivity Range (290 – 1999) μS/cm |
Conductometric method | P N - E N 2 7 8 8 8 : 1 9 9 9 | |
| 37 | Wastewater | pH Range 4,0 – 9,0 |
Potentiometric method | P N - E N I S O 1 0 5 2 3 : 2 0 1 2 | |
Reference standards (31)
Instrukcja ogólna IOL-27, wyd.01 z d n . 2 0 . 0 7 . 2 0 2 1 r.
P N - 9 2 / C - 0 4 5 9 0 /02
P N - E N 2 7 8 8 8 : 1 9 9 9
P N - E N I S O 1 0 5 2 3 : 2 0 1 2
P N -ISO 9297:1994
PN -77/C-04584
PN-82/C-04576/08
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.4; 4.4.5; 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt. 4. +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001 + Ap1:2016-06
PN-ISO 7150-1:2002
Procedura badawcza PB-13 wydanie 2 z dnia 06.03.2019 r.