🇵🇱 PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI PL

PCA AB 808 • Głogów, Poland • 37 methods

Water & wastewaterMicrobiology

PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI is a laboratory accredited by PCA under number AB 808 (Głogów, Poland). Its accreditation scope covers 37 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Wastewater, Water intended for human consumption, Water, Water, Water intended for human consumption, Swimming pool water, Water intended for human consumption, Swimming pool water, Water. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.

At a glance

  • Accreditation number: PCA AB 808
  • Methods in scope: 37
  • Types of test objects: 7
  • Techniques used: 10
  • City: Głogów, Poland
Accreditation number
AB 808
Accreditation body
PCA
Address
W GŁOGOWIE Sp. z o.o., ul. Łąkowa 52, 67-200 Głogów, DZIAŁ LABORATORIUM, ul. Krochmalna 3
City
Głogów, Poland

What this laboratory tests (7)

Analytical techniques used (10)

Laboratory sections (2)

Laboratory locations

Accreditation scope — test methods (37)

No. Test object Methodology / Parameters Technique Reference document
LABORATORY DEPARTMENT; Water Laboratory
1 Water intended for human consumption, Water Nitrite concentration
Range (0,020 – 0,50) mg/l
Spectrophotometric method PN-EN 26777:1999
2 Water intended for human consumption, Water Ammonium ion concentration
Range (0,060 – 1,20) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
3 Water intended for human consumption, Water Calcium concentration
Range (20 – 200) mg/l
Titrimetric method PN-ISO 6058:1999
4 Water intended for human consumption, Water Total iron concentration
Range (0,030 – 20) mg/l
Spectrophotometric method PN-ISO 6332:2001 + Ap1:2016-06
5 Water intended for human consumption, Water Total manganese concentration
Range (0,030 – 3,0) mg/l
Spectrophotometric method P N - 9 2 / C - 0 4 5 9 0 /02
6 Water intended for human consumption, Water Total content of calcium and magnesium (total hardness)
Range (10,0 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
7 Water intended for human consumption, Water Chloride concentration
Range (7,0 – 250) mg/l
Titrimetric method P N -ISO 9297:1994
8 Water intended for human consumption, Water Electrical conductivity
Range (290 – 2500) μS/cm
Conductometric method P N - E N 2 7 8 8 8 : 1 9 9 9
9 Water intended for human consumption, Water pH
Range 4,0 – 9,0
Potentiometric method P N - E N I S O 1 0 5 2 3 : 2 0 1 2
10 Water intended for human consumption, Water Colour
Range (3 – 48) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06
11 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
12 Swimming pool water Sampling for chemical and physical testing Instrukcja ogólna IOL-27, wyd.01 z d n . 2 0 . 0 7 . 2 0 2 1 r.
13 Water, Water intended for human consumption, Swimming pool water Turbidity
Range (0,20 – 20) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
14 Water, Water intended for human consumption, Swimming pool water Nitrate concentration
Range (0,88 – 65) mg/l
Spectrophotometric method PN-82/C-04576/08
15 Water, Water intended for human consumption, Swimming pool water Permanganate index (oxidisability)
Range (0,50 – 9,0) mg/l
Titrimetric method PN-EN ISO 8467:2001
16 Water intended for human consumption, Water Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
17 Water intended for human consumption, Water Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
18 Water intended for human consumption, Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
19 Water intended for human consumption, Swimming pool water, Water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
20 Water intended for human consumption, Swimming pool water, Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
21 Water intended for human consumption, Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
22 Water, Water intended for human consumption, Swimming pool water Sampling for microbiological analyses PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.4; 4.4.5; 4.4.6
LABORATORY DEPARTMENT; Wastewater Laboratory
23 Wastewater Nitrate nitrogen concentration
Range (0,20 – 54) mg /l
Spectrophotometric method PN-82/C-04576/08
24 Wastewater Nitrite nitrogen concentration
Range (0,0125 – 5,0) mg/l
Spectrophotometric method PN-EN 26777:1999
25 Wastewater Ammonium nitrogen concentration
Range (0,10 – 10) mg /l
Spectrophotometric method PN-ISO 7150-1:2002
26 Wastewater Ammonium nitrogen concentration
Range (1,0 – 200) mg/l
Titrimetric method PN-ISO 5664:2002
27 Wastewater Kjeldahl nitrogen concentration
Range (2,0 – 500) mg/l
Titrimetric method PN-EN 25663:2001
28 Wastewater Total nitrogen (calculated) Procedura badawcza PB-13 wydanie 2 z dnia 06.03.2019 r.
29 Wastewater Biochemical oxygen demand – BOD5
Range (3 – 3000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
30 Wastewater Total phosphorus concentration
Range (0,040 – 30) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
31 Wastewater Orthophosphate concentration
Range (0,040 – 30) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt. 4. +Ap1:2010+Ap2:2010
32 Wastewater Total suspended solids (TSS)
Range (2,0 – 3000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
33 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample (in situ) Range (4,0 – 25,0) °C pH of the collected wastewater sample (in situ) Range 4,0 – 9,0
Manual method; Automatic method; Potentiometric method PN-ISO 5667-10:2021-11 | PN -77/C-04584 | PN-EN ISO 10523:2012
34 Wastewater Chloride concentration
Range (5,0 – 150) mg/l
Titrimetric method P N -ISO 9297:1994
35 Wastewater Chemical oxygen demand COD
Range (10 – 4000 ) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
36 Wastewater Electrical conductivity
Range (290 – 1999) μS/cm
Conductometric method P N - E N 2 7 8 8 8 : 1 9 9 9
37 Wastewater pH
Range 4,0 – 9,0
Potentiometric method P N - E N I S O 1 0 5 2 3 : 2 0 1 2

Reference standards (31)

Instrukcja ogólna IOL-27, wyd.01 z d n . 2 0 . 0 7 . 2 0 2 1 r.
P N - 9 2 / C - 0 4 5 9 0 /02
P N - E N 2 7 8 8 8 : 1 9 9 9
P N - E N I S O 1 0 5 2 3 : 2 0 1 2
P N -ISO 9297:1994
PN -77/C-04584
PN-82/C-04576/08
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.4; 4.4.5; 4.4.6
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt. 4. +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001 + Ap1:2016-06
PN-ISO 7150-1:2002
Procedura badawcza PB-13 wydanie 2 z dnia 06.03.2019 r.