{"lab":{"_id":"69ad52a3de79e566650fb410","accr_number":"AB 808","country":"PL","accr_body":"PCA","address":"W GŁOGOWIE Sp. z o.o., ul. Łąkowa 52, 67-200 Głogów, DZIAŁ LABORATORIUM, ul. Krochmalna 3","categories":["water","microbiology"],"city":"Głogów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":37,"name":"PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI","parse_status":"parsed","parse_version":2,"pdf_files":["AB_808.pdf"],"scope_summary":"","search_text":"przedsiębiorstwo wodociągów i kanalizacji w głogowie sp. z o.o., ul. łąkowa 52, 67-200 głogów, dział laboratorium, ul. krochmalna 3 other water pharma electronics automotive microbiology","status":"active","updated_at":"2026-03-08T14:51:41.643Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-12T15:10:14.326Z","email_confidence":"high","email_mx":true,"email_source":"https://www.pwik.glogow.pl/index.php/kontakt","map_coord":[51.673811,16.100438],"map_geo":"nominatim-street","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Chemical tests and sampling water, drinking water, sewage"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water and drinking water"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków","en":"Tests of physical properties and sampling of water, drinking water, sewage,"}],"issue":{"no":"18","date":"01.07.2025"},"lab_locations":[{"name":"DZIAŁ LABORATORIUM","address":"ul. Krochmalna 3","city":null,"postal":null},{"name":"Laboratorium Wody","address":"ul. Wodna 1, 67-210 Serby","city":"Serby","postal":"67-210"},{"name":"Laboratorium Ścieków","address":"ul. Krochmalna 3, 67-200 Głogów","city":"Głogów","postal":"67-200"},{"name":"DZIAŁ LABORATORIUM; Laboratorium Wody","address":null,"city":null,"postal":null},{"name":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","address":null,"city":null,"postal":null}],"parse_date":"2026-08-12T15:10:14.326Z","parse_source":"agent-claude-code","scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/12/6a2e713b522fc4b76cf273f87a652257/AB%20808.pdf","has_en":true,"category_counts":{"water":37,"microbiology":3},"category_scores":{"water":34.23,"microbiology":0.23},"has_zh":true,"lab_locations_zh":[{"name":"DZIAŁ LABORATORIUM","address":"ul. Krochmalna 3","city":null,"postal":null},{"name":"Laboratorium Wody","address":"ul. Wodna 1, 67-210 Serby","city":"Serby","postal":"67-210"},{"name":"Laboratorium Ścieków","address":"ul. Krochmalna 3, 67-200 Głogów","city":"Głogów","postal":"67-200"},{"name":"实验室部；水实验室","address":null,"city":null,"postal":null},{"name":"实验室部；废水实验室","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7c8cd6097f6cdfc84f496d","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,020 – 0,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,020 – 0,50) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie azotynów\nZakres (0,020 – 0,50) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi, Woda Stezenie azotynow\nZakres (0,020 – 0,50) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,020 – 0,50) mg/l"}],"search_en":"Water intended for human consumption, Water Nitrite concentration Spectrophotometric method LABORATORY DEPARTMENT; Water Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 0,50) mg/l"}],"search_zh":"生活饮用水、水 亚硝酸盐浓度 分光光度法 实验室部；水实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f496e","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,060 – 1,20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,060 – 1,20) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie jonu amonowego\nZakres (0,060 – 1,20) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi, Woda Stezenie jonu amonowego\nZakres (0,060 – 1,20) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,060 – 1,20) mg/l"}],"search_en":"Water intended for human consumption, Water Ammonium ion concentration Spectrophotometric method LABORATORY DEPARTMENT; Water Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,060 – 1,20) mg/l"}],"search_zh":"生活饮用水、水 铵离子浓度 分光光度法 实验室部；水实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f496f","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(20 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (20 – 200) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie wapnia\nZakres (20 – 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda do spozycia przez ludzi, Woda Stezenie wapnia\nZakres (20 – 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(20 – 200) mg/l"}],"search_en":"Water intended for human consumption, Water Calcium concentration Titrimetric method LABORATORY DEPARTMENT; Water Laboratory Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, Water","parameters_zh":[{"name":"范围","range":"(20 – 200) mg/l"}],"search_zh":"生活饮用水、水 钙浓度 滴定法 实验室部；水实验室 范围 PN-ISO 6058:1999","technique_zh":"滴定法","methodology_zh":"钙浓度","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4970","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,030 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,030 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 + Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 + Ap1:2016-06"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie żelaza ogólnego\nZakres (0,030 – 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06 Woda do spozycia przez ludzi, Woda Stezenie zelaza ogolnego\nZakres (0,030 – 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,030 – 20) mg/l"}],"search_en":"Water intended for human consumption, Water Total iron concentration Spectrophotometric method LABORATORY DEPARTMENT; Water Laboratory Range PN-ISO 6332:2001 + Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,030 – 20) mg/l"}],"search_zh":"生活饮用水、水 总铁浓度 分光光度法 实验室部；水实验室 范围 PN-ISO 6332:2001 + Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4971","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie manganu ogólnego","parameters":[{"name":"Zakres","range":"(0,030 – 3,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu ogólnego\nZakres (0,030 – 3,0) mg/l\nMetoda spektrofotometryczna","reference":"P N - 9 2 / C - 0 4 5 9 0 /02","norm_bases":["P N - 9 2 / C - 0 4 5 9 0 /02"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie manganu ogólnego\nZakres (0,030 – 3,0) mg/l\nMetoda spektrofotometryczna P N - 9 2 / C - 0 4 5 9 0 /02 Woda do spozycia przez ludzi, Woda Stezenie manganu ogolnego\nZakres (0,030 – 3,0) mg/l\nMetoda spektrofotometryczna P N - 9 2 / C - 0 4 5 9 0 /02","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Total manganese concentration","parameters_en":[{"name":"Range","range":"(0,030 – 3,0) mg/l"}],"search_en":"Water intended for human consumption, Water Total manganese concentration Spectrophotometric method LABORATORY DEPARTMENT; Water Laboratory Range P N - 9 2 / C - 0 4 5 9 0 /02","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","parameters_zh":[{"name":"范围","range":"(0,030 – 3,0) mg/l"}],"search_zh":"生活饮用水、水 总锰浓度 分光光度法 实验室部；水实验室 范围 P N - 9 2 / C - 0 4 5 9 0 /02","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室","methodology_zh":"总锰浓度"},{"_id":"6a7c8cd6097f6cdfc84f4972","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(10,0 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10,0 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10,0 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi, Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (10,0 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(10,0 – 500) mg/l CaCO3"}],"search_en":"Water intended for human consumption, Water Total content of calcium and magnesium (total hardness) Titrimetric method LABORATORY DEPARTMENT; Water Laboratory Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(10,0 – 500) mg/l CaCO3"}],"search_zh":"生活饮用水、水 钙与镁总量（总硬度） 滴定法 实验室部；水实验室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4973","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(7,0 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (7,0 – 250) mg/l\nMetoda miareczkowa","reference":"P N -ISO 9297:1994","norm_bases":["P N -ISO 9297:1994"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Stężenie chlorków\nZakres (7,0 – 250) mg/l\nMetoda miareczkowa P N -ISO 9297:1994 Woda do spozycia przez ludzi, Woda Stezenie chlorkow\nZakres (7,0 – 250) mg/l\nMetoda miareczkowa P N -ISO 9297:1994","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(7,0 – 250) mg/l"}],"search_en":"Water intended for human consumption, Water Chloride concentration Titrimetric method LABORATORY DEPARTMENT; Water Laboratory Range P N -ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(7,0 – 250) mg/l"}],"search_zh":"生活饮用水、水 氯化物浓度 滴定法 实验室部；水实验室 范围 P N -ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4974","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(290 – 2500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (290 – 2500) μS/cm\nMetoda konduktometryczna","reference":"P N - E N 2 7 8 8 8 : 1 9 9 9","norm_bases":["P N - E N 2 7 8 8 8 : 1 9 9 9"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Przewodność elektryczna właściwa\nZakres (290 – 2500) μS/cm\nMetoda konduktometryczna P N - E N 2 7 8 8 8 : 1 9 9 9 Woda do spozycia przez ludzi, Woda Przewodnosc elektryczna wlasciwa\nZakres (290 – 2500) μS/cm\nMetoda konduktometryczna P N - E N 2 7 8 8 8 : 1 9 9 9","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(290 – 2500) μS/cm"}],"search_en":"Water intended for human consumption, Water Electrical conductivity Conductometric method LABORATORY DEPARTMENT; Water Laboratory Range P N - E N 2 7 8 8 8 : 1 9 9 9","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(290 – 2500) μS/cm"}],"search_zh":"生活饮用水、水 电导率 电导法 实验室部；水实验室 范围 P N - E N 2 7 8 8 8 : 1 9 9 9","technique_zh":"电导法","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4975","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna","reference":"P N - E N I S O 1 0 5 2 3 : 2 0 1 2","norm_bases":["P N - E N I S O 1 0 5 2 3 : 2 0 1 2"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna P N - E N I S O 1 0 5 2 3 : 2 0 1 2 Woda do spozycia przez ludzi, Woda pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna P N - E N I S O 1 0 5 2 3 : 2 0 1 2","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 9,0"}],"search_en":"Water intended for human consumption, Water pH Potentiometric method LABORATORY DEPARTMENT; Water Laboratory Range P N - E N I S O 1 0 5 2 3 : 2 0 1 2","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 9,0"}],"search_zh":"生活饮用水、水 pH 值 电位法 实验室部；水实验室 范围 P N - E N I S O 1 0 5 2 3 : 2 0 1 2","technique_zh":"电位法","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4976","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(3 – 48) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (3 – 48) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Barwa\nZakres (3 – 48) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06 Woda do spozycia przez ludzi, Woda Barwa\nZakres (3 – 48) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(3 – 48) mg/l Pt"}],"search_en":"Water intended for human consumption, Water Colour Spectrophotometric method LABORATORY DEPARTMENT; Water Laboratory Range PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(3 – 48) mg/l Pt"}],"search_zh":"生活饮用水、水 色度 分光光度法 实验室部；水实验室 范围 PN-EN ISO 7887:2012 Metoda C + Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4977","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing LABORATORY DEPARTMENT; Water Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 实验室部；水实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4978","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"Instrukcja ogólna IOL-27, wyd.01 z d n . 2 0 . 0 7 . 2 0 2 1 r.","norm_bases":["Instrukcja ogólna IOL-27, wyd.01 z d n . 2 0 . 0 7 . 2 0 2 1 r."],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych Instrukcja ogólna IOL-27, wyd.01 z d n . 2 0 . 0 7 . 2 0 2 1 r. Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych Instrukcja ogolna IOL-27, wyd.01 z d n . 2 0 . 0 7 . 2 0 2 1 r.","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Swimming pool water Sampling for chemical and physical testing LABORATORY DEPARTMENT; Water Laboratory Instrukcja ogólna IOL-27, wyd.01 z d n . 2 0 . 0 7 . 2 0 2 1 r.","test_object_en":"Swimming pool water","methodology_zh":"化学与物理检测用样品采集","search_zh":"游泳池水 化学与物理检测用样品采集 实验室部；水实验室 Instrukcja ogólna IOL-27, wyd.01 z d n . 2 0 . 0 7 . 2 0 2 1 r.","test_object_zh":"游泳池水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4979","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 – 20) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Mętność\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Metnosc\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 – 20) NTU"}],"search_en":"Water, Water intended for human consumption, Swimming pool water Turbidity Nephelometric method LABORATORY DEPARTMENT; Water Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 20) NTU"}],"search_zh":"水、生活饮用水、游泳池水 浊度 浊度法（散射法） 实验室部；水实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水、游泳池水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f497a","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,88 – 65) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,88 – 65) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Stężenie azotanów\nZakres (0,88 – 65) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Stezenie azotanow\nZakres (0,88 – 65) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,88 – 65) mg/l"}],"search_en":"Water, Water intended for human consumption, Swimming pool water Nitrate concentration Spectrophotometric method LABORATORY DEPARTMENT; Water Laboratory Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption, Swimming pool water","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,88 – 65) mg/l"}],"search_zh":"水、生活饮用水、游泳池水 硝酸盐浓度 分光光度法 实验室部；水实验室 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水、游泳池水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f497b","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Indeks nadmanganianowy (utlenialność)","parameters":[{"name":"Zakres","range":"(0,50 – 9,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy (utlenialność)\nZakres (0,50 – 9,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Indeks nadmanganianowy (utlenialność)\nZakres (0,50 – 9,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Indeks nadmanganianowy (utlenialnosc)\nZakres (0,50 – 9,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Permanganate index (oxidisability)","parameters_en":[{"name":"Range","range":"(0,50 – 9,0) mg/l"}],"search_en":"Water, Water intended for human consumption, Swimming pool water Permanganate index (oxidisability) Titrimetric method LABORATORY DEPARTMENT; Water Laboratory Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption, Swimming pool water","parameters_zh":[{"name":"范围","range":"(0,50 – 9,0) mg/l"}],"search_zh":"水、生活饮用水、游泳池水 高锰酸盐指数（耗氧量） 滴定法 实验室部；水实验室 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水、游泳池水","lab_section_zh":"实验室部；水实验室","methodology_zh":"高锰酸盐指数（耗氧量）"},{"_id":"6a7c8cd6097f6cdfc84f497c","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Liczba enterokoków","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Liczba enterokoków\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi, Woda Liczba enterokokow\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Enterococci count","search_en":"Water intended for human consumption, Water Enterococci count Membrane filtration method LABORATORY DEPARTMENT; Water Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"肠球菌计数","search_zh":"生活饮用水、水 肠球菌计数 膜过滤法 实验室部；水实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f497d","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Ogólna liczba mikroorganizmów w 22 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi, Woda Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Total viable count at 22 °C","search_en":"Water intended for human consumption, Water Total viable count at 22 °C Plate method (pour plate) LABORATORY DEPARTMENT; Water Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption, Water","methodology_zh":"22 °C 微生物总数","search_zh":"生活饮用水、水 22 °C 微生物总数 平板法（倾注培养） 实验室部；水实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f497e","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi, Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption, Water Coliform bacteria count Membrane filtration method LABORATORY DEPARTMENT; Water Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, Water","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水、水 大肠菌群计数 膜过滤法 实验室部；水实验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f497f","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach, Woda","methodology":"Ogólna liczba mikroorganizmów w 36 °C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach, Woda Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi, Woda na plywalniach, Woda Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Total viable count at 36 °C","search_en":"Water intended for human consumption, Swimming pool water, Water Total viable count at 36 °C Plate method (pour plate) LABORATORY DEPARTMENT; Water Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption, Swimming pool water, Water","methodology_zh":"36 °C 微生物总数","search_zh":"36 °C 微生物总数 平板法（倾注培养） 实验室部；水实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4980","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach, Woda","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach, Woda Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi, Woda na plywalniach, Woda Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption, Swimming pool water, Water Escherichia coli count Membrane filtration method LABORATORY DEPARTMENT; Water Laboratory PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, Swimming pool water, Water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"大肠埃希氏菌（Escherichia coli）计数 膜过滤法 实验室部；水实验室 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4981","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi, Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water intended for human consumption, Swimming pool water Pseudomonas aeruginosa count Membrane filtration method LABORATORY DEPARTMENT; Water Laboratory PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption, Swimming pool water","methodology_zh":"铜绿假单胞菌计数","search_zh":"生活饮用水、游泳池水 铜绿假单胞菌计数 膜过滤法 实验室部；水实验室 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"生活饮用水、游泳池水","lab_section_zh":"实验室部；水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4982","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Pobieranie próbek do analiz mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do analiz mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.4; 4.4.5; 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.4; 4.4.5; 4.4.6"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Woda na pływalniach Pobieranie próbek do analiz mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.4; 4.4.5; 4.4.6 Woda, Woda do spozycia przez ludzi, Woda na plywalniach Pobieranie probek do analiz mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt 4.4.4; 4.4.5; 4.4.6","categories":["water","microbiology"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Water Laboratory","methodology_en":"Sampling for microbiological analyses","search_en":"Water, Water intended for human consumption, Swimming pool water Sampling for microbiological analyses LABORATORY DEPARTMENT; Water Laboratory PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.4; 4.4.5; 4.4.6","test_object_en":"Water, Water intended for human consumption, Swimming pool water","search_zh":"水、生活饮用水、游泳池水 用于微生物分析的采样 实验室部；水实验室 PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.4; 4.4.5; 4.4.6","test_object_zh":"水、生活饮用水、游泳池水","lab_section_zh":"实验室部；水实验室","methodology_zh":"用于微生物分析的采样"},{"_id":"6a7c8cd6097f6cdfc84f4983","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,20 – 54) mg /l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,20 – 54) mg /l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,20 – 54) mg /l\nMetoda spektrofotometryczna PN-82/C-04576/08 Scieki Stezenie azotu azotanowego\nZakres (0,20 – 54) mg /l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,20 – 54) mg /l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method LABORATORY DEPARTMENT; Wastewater Laboratory Range PN-82/C-04576/08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 54) mg /l"}],"search_zh":"污水 硝态氮浓度 分光光度法 实验室部；废水实验室 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4984","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,0125 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,0125 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,0125 – 5,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,0125 – 5,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,0125 – 5,0) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method LABORATORY DEPARTMENT; Wastewater Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,0125 – 5,0) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 实验室部；废水实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4985","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,10 – 10) mg /l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,10 – 10) mg /l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,10 – 10) mg /l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Scieki Stezenie azotu amonowego\nZakres (0,10 – 10) mg /l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 10) mg /l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method LABORATORY DEPARTMENT; Wastewater Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 10) mg /l"}],"search_zh":"污水 氨氮浓度 分光光度法 实验室部；废水实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4986","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (1,0 – 200) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (1,0 – 200) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (1,0 – 200) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 200) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method LABORATORY DEPARTMENT; Wastewater Laboratory Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 200) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 实验室部；废水实验室 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4987","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(2,0 – 500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (2,0 – 500) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (2,0 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (2,0 – 500) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(2,0 – 500) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method LABORATORY DEPARTMENT; Wastewater Laboratory Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 500) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 实验室部；废水实验室 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4988","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Azot ogólny (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Azot ogólny (z obliczeń)","reference":"Procedura badawcza PB-13 wydanie 2 z dnia 06.03.2019 r.","norm_bases":["Procedura badawcza PB-13 wydanie 2 z dnia 06.03.2019 r."],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Azot ogólny (z obliczeń) Procedura badawcza PB-13 wydanie 2 z dnia 06.03.2019 r. Scieki Azot ogolny (z obliczen) Procedura badawcza PB-13 wydanie 2 z dnia 06.03.2019 r.","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Total nitrogen (calculated)","search_en":"Wastewater Total nitrogen (calculated) LABORATORY DEPARTMENT; Wastewater Laboratory Procedura badawcza PB-13 wydanie 2 z dnia 06.03.2019 r.","test_object_en":"Wastewater","search_zh":"污水 总氮（由计算得出） 实验室部；废水实验室 Procedura badawcza PB-13 wydanie 2 z dnia 06.03.2019 r.","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室","methodology_zh":"总氮（由计算得出）"},{"_id":"6a7c8cd6097f6cdfc84f4989","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu – BZT5","parameters":[{"name":"Zakres","range":"(3 – 3000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowanie tlenu – BZT5\nZakres (3 – 3000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Biochemical oxygen demand – BOD5","parameters_en":[{"name":"Range","range":"(3 – 3000) mg/l O2"}],"search_en":"Wastewater Biochemical oxygen demand – BOD5 Electrochemical method LABORATORY DEPARTMENT; Wastewater Laboratory Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(3 – 3000) mg/l O2"}],"search_zh":"污水 五日生化需氧量（BOD5） 电化学法 实验室部；废水实验室 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"五日生化需氧量（BOD5）","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f498a","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,040 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,040 – 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,040 – 30) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,040 – 30) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,040 – 30) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method LABORATORY DEPARTMENT; Wastewater Laboratory Range PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 30) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 实验室部；废水实验室 范围 PN-EN ISO 6878:2006 pkt. 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f498b","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,040 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,040 – 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt. 4. +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt. 4. +Ap1:2010+Ap2:2010"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie ortofosforanów\nZakres (0,040 – 30) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4. +Ap1:2010+Ap2:2010 Scieki Stezenie ortofosforanow\nZakres (0,040 – 30) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt. 4. +Ap1:2010+Ap2:2010","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,040 – 30) mg/l"}],"search_en":"Wastewater Orthophosphate concentration Spectrophotometric method LABORATORY DEPARTMENT; Wastewater Laboratory Range PN-EN ISO 6878:2006 pkt. 4. +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,040 – 30) mg/l"}],"search_zh":"污水 正磷酸盐浓度 分光光度法 实验室部；废水实验室 范围 PN-EN ISO 6878:2006 pkt. 4. +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"正磷酸盐浓度","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f498c","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 3000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (2,0 – 3000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 3000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method LABORATORY DEPARTMENT; Wastewater Laboratory Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 3000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 实验室部；废水实验室 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f498d","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[{"name":"Temperatura pobranej próbki ścieków (in situ)"},{"name":"Zakres","range":"(4,0 – 25,0) °C"},{"name":"pH pobranej próbki ścieków (in situ)"},{"name":"Zakres","range":"4,0 – 9,0"}],"technique":"Metoda manualna; Metoda automatyczna; Metoda potencjometryczna","techniques":["Metoda manualna","Metoda automatyczna","Metoda potencjometryczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków (in situ)\nZakres (4,0 – 25,0) °C\npH pobranej próbki ścieków (in situ)\nZakres 4,0 – 9,0\nMetoda manualna; Metoda automatyczna; Metoda potencjometryczna","reference":"PN-ISO 5667-10:2021-11 | PN -77/C-04584 | PN-EN ISO 10523:2012","norm_bases":["PN-ISO 5667-10:2021-11","PN -77/C-04584","PN-EN ISO 10523:2012"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków (in situ)\nZakres (4,0 – 25,0) °C\npH pobranej próbki ścieków (in situ)\nZakres 4,0 – 9,0\nMetoda manualna; Metoda automatyczna; Metoda potencjometryczna PN-ISO 5667-10:2021-11 | PN -77/C-04584 | PN-EN ISO 10523:2012 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow (in situ)\nZakres (4,0 – 25,0) °C\npH pobranej probki sciekow (in situ)\nZakres 4,0 – 9,0\nMetoda manualna; Metoda automatyczna; Metoda potencjometryczna PN-ISO 5667-10:2021-11 | PN -77/C-04584 | PN-EN ISO 10523:2012","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Sampling for chemical and physical testing","parameters_en":[{"name":"Temperature of the collected wastewater sample (in situ)"},{"name":"Range","range":"(4,0 – 25,0) °C"},{"name":"pH of the collected wastewater sample (in situ)"},{"name":"Range","range":"4,0 – 9,0"}],"search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method; Potentiometric method LABORATORY DEPARTMENT; Wastewater Laboratory Temperature of the collected wastewater sample (in situ) Range pH of the collected wastewater sample (in situ) Range PN-ISO 5667-10:2021-11 | PN -77/C-04584 | PN-EN ISO 10523:2012","technique_en":"Manual method; Automatic method; Potentiometric method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"Temperatura pobranej próbki ścieków (in situ)"},{"name":"范围","range":"(4,0 – 25,0) °C"},{"name":"pH pobranej próbki ścieków (in situ)"},{"name":"范围","range":"4,0 – 9,0"}],"search_zh":"污水 化学与物理检测用样品采集 实验室部；废水实验室 范围 范围 PN-ISO 5667-10:2021-11 | PN -77/C-04584 | PN-EN ISO 10523:2012","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f498e","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 150) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 150) mg/l\nMetoda miareczkowa","reference":"P N -ISO 9297:1994","norm_bases":["P N -ISO 9297:1994"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (5,0 – 150) mg/l\nMetoda miareczkowa P N -ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5,0 – 150) mg/l\nMetoda miareczkowa P N -ISO 9297:1994","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 150) mg/l"}],"search_en":"Wastewater Chloride concentration Titrimetric method LABORATORY DEPARTMENT; Wastewater Laboratory Range P N -ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 150) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 实验室部；废水实验室 范围 P N -ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f498f","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu ChZT","parameters":[{"name":"Zakres","range":"(10 – 4000 ) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu ChZT\nZakres (10 – 4000 ) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu ChZT\nZakres (10 – 4000 ) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu ChZT\nZakres (10 – 4000 ) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Chemical oxygen demand COD","parameters_en":[{"name":"Range","range":"(10 – 4000 ) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand COD Spectrophotometric method LABORATORY DEPARTMENT; Wastewater Laboratory Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"化学需氧量 ChZT（COD）","parameters_zh":[{"name":"范围","range":"(10 – 4000 ) mg/l O2"}],"search_zh":"污水 化学需氧量 ChZT（COD） 分光光度法 实验室部；废水实验室 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4990","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(290 – 1999) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (290 – 1999) μS/cm\nMetoda konduktometryczna","reference":"P N - E N 2 7 8 8 8 : 1 9 9 9","norm_bases":["P N - E N 2 7 8 8 8 : 1 9 9 9"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Przewodność elektryczna właściwa\nZakres (290 – 1999) μS/cm\nMetoda konduktometryczna P N - E N 2 7 8 8 8 : 1 9 9 9 Scieki Przewodnosc elektryczna wlasciwa\nZakres (290 – 1999) μS/cm\nMetoda konduktometryczna P N - E N 2 7 8 8 8 : 1 9 9 9","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(290 – 1999) μS/cm"}],"search_en":"Wastewater Electrical conductivity Conductometric method LABORATORY DEPARTMENT; Wastewater Laboratory Range P N - E N 2 7 8 8 8 : 1 9 9 9","technique_en":"Conductometric method","test_object_en":"Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(290 – 1999) μS/cm"}],"search_zh":"污水 电导率 电导法 实验室部；废水实验室 范围 P N - E N 2 7 8 8 8 : 1 9 9 9","technique_zh":"电导法","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室"},{"_id":"6a7c8cd6097f6cdfc84f4991","lab_id":"69ad52a3de79e566650fb410","country":"PL","accr_number":"AB 808","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 9,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna","reference":"P N - E N I S O 1 0 5 2 3 : 2 0 1 2","norm_bases":["P N - E N I S O 1 0 5 2 3 : 2 0 1 2"],"lab_section":"DZIAŁ LABORATORIUM; Laboratorium Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna P N - E N I S O 1 0 5 2 3 : 2 0 1 2 Scieki pH\nZakres 4,0 – 9,0\nMetoda potencjometryczna P N - E N I S O 1 0 5 2 3 : 2 0 1 2","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"LABORATORY DEPARTMENT; Wastewater Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 9,0"}],"search_en":"Wastewater pH Potentiometric method LABORATORY DEPARTMENT; Wastewater Laboratory Range P N - E N I S O 1 0 5 2 3 : 2 0 1 2","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 9,0"}],"search_zh":"污水 pH 值 电位法 实验室部；废水实验室 范围 P N - E N I S O 1 0 5 2 3 : 2 0 1 2","technique_zh":"电位法","test_object_zh":"污水","lab_section_zh":"实验室部；废水实验室"}],"has_pdf":false}