🇵🇱 STALPRODUKT S.A. PL
Water & wastewaterEnvironmentMaterials & polymers
STALPRODUKT S.A. is a laboratory accredited by PCA under number AB 801 (Bochnia, Poland). Its accreditation scope covers 33 test methods in the following areas: Water & wastewater, Environment, Materials & polymers. Test objects include: Water, Wastewater, Water, Workplace environment – noise, Steel. Most frequently used techniques: Spectrophotometric method, Gravimetric method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 801
- Methods in scope: 33
- Types of test objects: 6
- Techniques used: 12
- City: Bochnia, Poland
- Accreditation number
- AB 801
- Accreditation body
- PCA
- Address
- LABORATORIUM CENTRALNE, ul. Wygoda 69, 32-700 Bochnia
- City
- Bochnia, Poland
What this laboratory tests (6)
- Water, Wastewater — 21 methods
- Water — 3 methods
- Workplace environment – noise — 3 methods
- Steel — 2 methods
- Wastewater — 2 methods
- Workplace environment – indoor electric lighting — 2 methods
Analytical techniques used (12)
- Spectrophotometric method — 6 methods
- Gravimetric method — 4 methods
- Titrimetric method — 4 methods
- Direct measurement method — 3 methods
- High-temperature combustion with IR detection — 2 methods
- Inductively coupled plasma optical emission spectrometry (ICP-OES) — 2 methods
- Conductometric method + — 1 method
- Electrochemical method — 1 method
- Gas chromatography with flame ionization detection (GC – FID) — 1 method
- Manual method — 1 method
- Method: spectrophotometric — 1 method
- Potentiometric method + — 1 method
Laboratory locations
- LABORATORIUM CENTRALNE — ul. Wygoda 69
Accreditation scope — test methods (33)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium Centralne | |||||
| 1 | Water, Wastewater | pH Range 2,0 – 12,0 Regulated area: Badania wykonywane w siedzibie i poza siedzibą Laboratorium |
Potentiometric method + | PN-EN ISO 10523:2012 | |
| 2 | Water, Wastewater | Electrical conductivity Range (150 – 12000) μS/cm Regulated area: Badania wykonywane w siedzibie i poza siedzibą Laboratorium |
Conductometric method + | PN-EN 27888:1999 | |
| 3 | Water, Wastewater | Chloride concentration Range (5,0 – 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 4 | Water, Wastewater | Iron concentration Range (0,020 – 20) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 pkt. 7.1.1 | |
| 5 | Water, Wastewater | Sulfate concentration Range (10 – 5000) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 6 | Water, Wastewater | Dissolved solids Range (10 – 5000) mg/l |
Gravimetric method | PN-EN 15216:2022-03 | |
| 7 | Water, Wastewater | Chemical oxygen demand - COD-Cr Range (10 – 1000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 8 | Water, Wastewater | Organic substances extractable with petroleum ether Range (5,0 – 100) mg/l |
Gravimetric method | PN-86/C-04573/01 | |
| 9 | Water, Wastewater | Phenol index Range (0,002 – 0,10) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 – metoda B | |
| 10 | Water, Wastewater | Total suspended solids (TSS) Range (2,0 – 1000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 11 | Water, Wastewater | Biochemical oxygen demand - BOD5 Range (2 – 1000) mg /l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019-12 | |
| 12 | Water, Wastewater | Anionic detergent concentration Range (0,10 – 20) mg/l |
Spectrophotometric method | PN-EN 903:2002 | |
| 13 | Water, Wastewater | Total phosphorus concentration Range (0,050 – 10) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 | |
| 14 | Water, Wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 15 | Water, Wastewater | Nitrate nitrogen concentration Range (0,10 – 30) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 16 | Water, Wastewater | Nitrite nitrogen concentration Range (0,015 – 10) mg/l |
Method: spectrophotometric | PN-EN 26777:1999 | |
| 17 | Water, Wastewater | Mineral oil index (concentration of petroleum hydrocarbons) Range (0,30 – 20) mg/l |
Gas chromatography with flame ionization detection (GC – FID) | PN-EN 9377-2:2003 | |
| 18 | Water, Wastewater | Kjeldahl nitrogen concentration Range (5,0 – 50) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 19 | Water, Wastewater | Ammonium nitrogen concentration Range (1,0 – 50) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 20 | Water, Wastewater | Concentration of: titanium, copper, nickel, lead, chromium and zinc Range (0,001 – 10,0) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 21 | Water, Wastewater | Iron concentration Range (0,010 – 10,0) mg/l |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 22 | Wastewater | Sampling for chemical and physical testing | Manual method | PN-ISO 5667-10:2021-11 | |
| 23 | Wastewater | Temperature of the collected wastewater sample Range (0,50 – 40) °C |
PN-77/C-04584 | ||
| 24 | Water | Sampling for chemical and physical testing | PN-ISO 5667-11:2017-10 z wył. pkt. 5.2; 6.1.2; 6.2 i 6.3 | ||
| 25 | Water | Temperature of the collected water sample Range (0,50 – 40) °C |
PN-EN ISO 5667-6:2016-12 pkt. 7.4 | PN-77/C-04584 | ||
| 26 | Water | Permanganate index Range (1,0 – 100) mg/l |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 27 | Workplace environment – noise | A-weighted equivalent sound level Maximum A-weighted sound level Range (39 – 135) dB |
Direct measurement method | PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11 | |
| 28 | Workplace environment – noise | C-weighted peak sound pressure level Range (39 – 138) dB |
Direct measurement method | PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11 | |
| 29 | Workplace environment – noise | Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy; - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) | PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11 | ||
| 30 | Workplace environment – indoor electric lighting | Illuminance Range (10 – 2000) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 31 | Workplace environment – indoor electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 32 | Steel | Carbon content Range (0,0007 – 0,0900) % |
High-temperature combustion with IR detection | PN-EN ISO 9556:2003 | |
| 33 | Steel | Sulfur content Range (0,0007 – 0,0300) % |
High-temperature combustion with IR detection | PN-EN 24935:1994 | |
Reference standards (30)
PN-73/C-04576/14
PN-77/C-04584
PN-82/C-04576.08
PN-83/E-04040.03
PN-86/C-04573/01
PN-EN 15216:2022-03
PN-EN 24935:1994
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN 9377-2:2003
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 5667-6:2016-12 pkt. 7.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010
PN-EN ISO 8467:2001
PN-EN ISO 9556:2003
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10 z wył. pkt. 5.2; 6.1.2; 6.2 i 6.3
PN-ISO 6332:2001+Ap1:2016-06 pkt. 7.1.1
PN-ISO 6439:1994 – metoda B
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-N 01307:1994