{"lab":{"_id":"69ad52a3de79e566650fb408","accr_number":"AB 801","country":"PL","accr_body":"PCA","address":"LABORATORIUM CENTRALNE, ul. Wygoda 69, 32-700 Bochnia","categories":["water","environment","materials"],"city":"Bochnia","imported_at":"2026-03-08T10:42:43.265Z","methods_count":33,"name":"STALPRODUKT S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_801.pdf"],"scope_summary":"","search_text":"stalprodukt s.a. laboratorium centralne, ul. wygoda 69, 32-700 bochnia water pharma electronics other food environment metrology materials","status":"active","updated_at":"2026-03-08T14:51:41.239Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:06:31.965Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20801,podmiot.html","fields_of_testing":[{"codes":"C/8","pl":"Badania chemiczne wyrobów i materiałów konstrukcyjnych","en":"Chemical tests of construction products and materials"},{"codes":"C/28/P, C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe - hałas i oświetlenie","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmul factors - noise and ilumination"},{"codes":"N/28/P, N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków","en":"Tests of physical properties and sampling of water and sewage"}],"issue":{"no":"19","date":"24.06.2026"},"parse_date":"2026-08-18T01:06:31.965Z","parse_source":"agent-claude-code","map_coord":[49.985381,20.440637],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM CENTRALNE","address":"ul. Wygoda 69","city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/647b37f40f54dfe6901ebed3f0af44b2/AB%20801.pdf","has_en":true,"category_counts":{"water":26,"environment":5,"materials":2,"petro":1},"category_scores":{"water":19.88,"environment":0.74,"materials":0.12,"petro":0.03},"has_zh":true},"methods":[{"_id":"6a83b017af14b9c0e7b206bf","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna +","techniques":["Metoda potencjometryczna +"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna +","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":"Badania wykonywane w siedzibie i poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, Ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna + PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna + PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"search_en":"Water, Wastewater pH Potentiometric method + Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method +","test_object_en":"Water, Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、污水 pH 值 范围 PN-EN ISO 10523:2012","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206c0","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(150 – 12000) μS/cm"}],"technique":"Metoda konduktometryczna +","techniques":["Metoda konduktometryczna +"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (150 – 12000) μS/cm\nMetoda konduktometryczna +","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":"Badania wykonywane w siedzibie i poza siedzibą Laboratorium","flexible":false,"search_text":"Woda, Ścieki Przewodność elektryczna właściwa\nZakres (150 – 12000) μS/cm\nMetoda konduktometryczna + PN-EN 27888:1999 Woda, Scieki Przewodnosc elektryczna wlasciwa\nZakres (150 – 12000) μS/cm\nMetoda konduktometryczna + PN-EN 27888:1999","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(150 – 12000) μS/cm"}],"search_en":"Water, Wastewater Electrical conductivity Conductometric method + Range PN-EN 27888:1999","technique_en":"Conductometric method +","test_object_en":"Water, Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(150 – 12000) μS/cm"}],"search_zh":"水、污水 电导率 范围 PN-EN 27888:1999","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206c1","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 400) mg/l"}],"search_en":"Water, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 400) mg/l"}],"search_zh":"水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206c2","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,020 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,020 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06 pkt. 7.1.1","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06 pkt. 7.1.1"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie żelaza\nZakres (0,020 – 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 pkt. 7.1.1 Woda, Scieki Stezenie zelaza\nZakres (0,020 – 20) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 pkt. 7.1.1","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,020 – 20) mg/l"}],"search_en":"Water, Wastewater Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06 pkt. 7.1.1","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 – 20) mg/l"}],"search_zh":"水、污水 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06 pkt. 7.1.1","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206c3","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Scieki Stezenie siarczanow\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 5000) mg/l"}],"search_en":"Water, Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206c4","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje rozpuszczone","parameters":[{"name":"Zakres","range":"(10 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje rozpuszczone\nZakres (10 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje rozpuszczone\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, Scieki Substancje rozpuszczone\nZakres (10 – 5000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved solids","parameters_en":[{"name":"Range","range":"(10 – 5000) mg/l"}],"search_en":"Water, Wastewater Dissolved solids Gravimetric method Range PN-EN 15216:2022-03","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 5000) mg/l"}],"search_zh":"水、污水 溶解性固体 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"溶解性固体"},{"_id":"6a83b017af14b9c0e7b206c5","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 1000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu - ChZT-Cr\nZakres (10 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand - COD-Cr","parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l O2"}],"search_en":"Water, Wastewater Chemical oxygen demand - COD-Cr Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD-Cr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD-Cr）"},{"_id":"6a83b017af14b9c0e7b206c6","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Substancje organiczne ekstrahujące się eterem naftowym","parameters":[{"name":"Zakres","range":"(5,0 – 100) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje organiczne ekstrahujące się eterem naftowym\nZakres (5,0 – 100) mg/l\nMetoda wagowa","reference":"PN-86/C-04573/01","norm_bases":["PN-86/C-04573/01"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Substancje organiczne ekstrahujące się eterem naftowym\nZakres (5,0 – 100) mg/l\nMetoda wagowa PN-86/C-04573/01 Woda, Scieki Substancje organiczne ekstrahujace sie eterem naftowym\nZakres (5,0 – 100) mg/l\nMetoda wagowa PN-86/C-04573/01","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Organic substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(5,0 – 100) mg/l"}],"search_en":"Water, Wastewater Organic substances extractable with petroleum ether Gravimetric method Range PN-86/C-04573/01","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(5,0 – 100) mg/l"}],"search_zh":"水、污水 石油醚可萃取有机物质 重量法 范围 PN-86/C-04573/01","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"石油醚可萃取有机物质"},{"_id":"6a83b017af14b9c0e7b206c7","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,002 – 0,10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,002 – 0,10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 – metoda B","norm_bases":["PN-ISO 6439:1994 – metoda B"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,002 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 – metoda B Woda, Scieki Indeks fenolowy\nZakres (0,002 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 – metoda B","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,002 – 0,10) mg/l"}],"search_en":"Water, Wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994 – metoda B","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,002 – 0,10) mg/l"}],"search_zh":"水、污水 酚指数 分光光度法 范围 PN-ISO 6439:1994 – metoda B","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"酚指数"},{"_id":"6a83b017af14b9c0e7b206c8","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206c9","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","parameters":[{"name":"Zakres","range":"(2 – 1000) mg /l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (2 – 1000) mg /l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (2 – 1000) mg /l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (2 – 1000) mg /l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand - BOD5","parameters_en":[{"name":"Range","range":"(2 – 1000) mg /l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(2 – 1000) mg /l O2"}],"search_zh":"水、污水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a83b017af14b9c0e7b206ca","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie detergentów anionowych","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie detergentów anionowych\nZakres (0,10 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie detergentów anionowych\nZakres (0,10 – 20) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Woda, Scieki Stezenie detergentow anionowych\nZakres (0,10 – 20) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anionic detergent concentration","parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/l"}],"search_en":"Water, Wastewater Anionic detergent concentration Spectrophotometric method Range PN-EN 903:2002","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/l"}],"search_zh":"水、污水 阴离子洗涤剂浓度 分光光度法 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"阴离子洗涤剂浓度"},{"_id":"6a83b017af14b9c0e7b206cb","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,050 – 10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,050 – 10) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,050 – 10) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,050 – 10) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,050 – 10) mg/l"}],"search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 10) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 p.7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206cc","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Woda, Scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206cd","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,10 – 30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 – 30) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,10 – 30) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Scieki Stezenie azotu azotanowego\nZakres (0,10 – 30) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 30) mg/l"}],"search_en":"Water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 30) mg/l"}],"search_zh":"水、污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206ce","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,015 – 10) mg/l"}],"technique":"Metoda: spektrofotometryczna","techniques":["Metoda: spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,015 – 10) mg/l\nMetoda: spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,015 – 10) mg/l\nMetoda: spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,015 – 10) mg/l\nMetoda: spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,015 – 10) mg/l"}],"search_en":"Water, Wastewater Nitrite nitrogen concentration Method: spectrophotometric Range PN-EN 26777:1999","technique_en":"Method: spectrophotometric","test_object_en":"Water, Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,015 – 10) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 范围 PN-EN 26777:1999","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206cf","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Indeks oleju mineralnego (stężenie węglowodorów ropopochodnych)","parameters":[{"name":"Zakres","range":"(0,30 – 20) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC – FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC – FID)"],"computed":[],"activity":"Indeks oleju mineralnego (stężenie węglowodorów ropopochodnych)\nZakres (0,30 – 20) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC – FID)","reference":"PN-EN 9377-2:2003","norm_bases":["PN-EN 9377-2:2003"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Indeks oleju mineralnego (stężenie węglowodorów ropopochodnych)\nZakres (0,30 – 20) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo - jonizacyjną (GC – FID) PN-EN 9377-2:2003 Woda, Scieki Indeks oleju mineralnego (stezenie weglowodorow ropopochodnych)\nZakres (0,30 – 20) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo - jonizacyjna (GC – FID) PN-EN 9377-2:2003","categories":["water","petro"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mineral oil index (concentration of petroleum hydrocarbons)","parameters_en":[{"name":"Range","range":"(0,30 – 20) mg/l"}],"search_en":"Water, Wastewater Mineral oil index (concentration of petroleum hydrocarbons) Gas chromatography with flame ionization detection (GC – FID) Range PN-EN 9377-2:2003","technique_en":"Gas chromatography with flame ionization detection (GC – FID)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,30 – 20) mg/l"}],"search_zh":"水、污水 范围 PN-EN 9377-2:2003","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206d0","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(5,0 – 50) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (5,0 – 50) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (5,0 – 50) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (5,0 – 50) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(5,0 – 50) mg/l"}],"search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 50) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206d1","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 – 50) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (1,0 – 50) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (1,0 – 50) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (1,0 – 50) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 50) mg/l"}],"search_en":"Water, Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Water, Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 50) mg/l"}],"search_zh":"水、污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206d2","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie: tytanu, miedzi, niklu, ołowiu, chromu i cynku","parameters":[{"name":"Zakres","range":"(0,001 – 10,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie: tytanu, miedzi, niklu, ołowiu, chromu i cynku\nZakres (0,001 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie: tytanu, miedzi, niklu, ołowiu, chromu i cynku\nZakres (0,001 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Scieki Stezenie: tytanu, miedzi, niklu, olowiu, chromu i cynku\nZakres (0,001 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of: titanium, copper, nickel, lead, chromium and zinc","parameters_en":[{"name":"Range","range":"(0,001 – 10,0) mg/l"}],"search_en":"Water, Wastewater Concentration of: titanium, copper, nickel, lead, chromium and zinc Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(0,001 – 10,0) mg/l"}],"search_zh":"水、污水 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206d3","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,010 – 10,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,010 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie żelaza\nZakres (0,010 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Scieki Stezenie zelaza\nZakres (0,010 – 10,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,010 – 10,0) mg/l"}],"search_en":"Water, Wastewater Iron concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Range PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water, Wastewater","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 10,0) mg/l"}],"search_zh":"水、污水 铁浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、污水"},{"_id":"6a83b017af14b9c0e7b206d4","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","test_object_zh":"污水","technique_zh":"手工法"},{"_id":"6a83b017af14b9c0e7b206d5","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura pobranej próbki ścieków","parameters":[{"name":"Zakres","range":"(0,50 – 40) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki ścieków\nZakres (0,50 – 40) °C","reference":"PN-77/C-04584","norm_bases":["PN-77/C-04584"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura pobranej próbki ścieków\nZakres (0,50 – 40) °C PN-77/C-04584 Scieki Temperatura pobranej probki sciekow\nZakres (0,50 – 40) °C PN-77/C-04584","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected wastewater sample","parameters_en":[{"name":"Range","range":"(0,50 – 40) °C"}],"search_en":"Wastewater Temperature of the collected wastewater sample Range PN-77/C-04584","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,50 – 40) °C"}],"search_zh":"污水 所采废水样品的温度 范围 PN-77/C-04584","test_object_zh":"污水","methodology_zh":"所采废水样品的温度"},{"_id":"6a83b017af14b9c0e7b206d6","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-11:2017-10 z wył. pkt. 5.2; 6.1.2; 6.2 i 6.3","norm_bases":["PN-ISO 5667-11:2017-10 z wył. pkt. 5.2; 6.1.2; 6.2 i 6.3"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wył. pkt. 5.2; 6.1.2; 6.2 i 6.3 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-11:2017-10 z wyl. pkt. 5.2; 6.1.2; 6.2 i 6.3","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-11:2017-10 z wył. pkt. 5.2; 6.1.2; 6.2 i 6.3","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-11:2017-10 z wył. pkt. 5.2; 6.1.2; 6.2 i 6.3","test_object_zh":"水"},{"_id":"6a83b017af14b9c0e7b206d7","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda","methodology":"Temperatura pobranej próbki wody","parameters":[{"name":"Zakres","range":"(0,50 – 40) °C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura pobranej próbki wody\nZakres (0,50 – 40) °C","reference":"PN-EN ISO 5667-6:2016-12 pkt. 7.4 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 pkt. 7.4","PN-77/C-04584"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Temperatura pobranej próbki wody\nZakres (0,50 – 40) °C PN-EN ISO 5667-6:2016-12 pkt. 7.4 | PN-77/C-04584 Woda Temperatura pobranej probki wody\nZakres (0,50 – 40) °C PN-EN ISO 5667-6:2016-12 pkt. 7.4 | PN-77/C-04584","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature of the collected water sample","parameters_en":[{"name":"Range","range":"(0,50 – 40) °C"}],"search_en":"Water Temperature of the collected water sample Range PN-EN ISO 5667-6:2016-12 pkt. 7.4 | PN-77/C-04584","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,50 – 40) °C"}],"search_zh":"水 所采水样的温度 范围 PN-EN ISO 5667-6:2016-12 pkt. 7.4 | PN-77/C-04584","test_object_zh":"水","methodology_zh":"所采水样的温度"},{"_id":"6a83b017af14b9c0e7b206d8","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Woda","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(1,0 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (1,0 – 100) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Indeks nadmanganianowy\nZakres (1,0 – 100) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy\nZakres (1,0 – 100) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(1,0 – 100) mg/l"}],"search_en":"Water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(1,0 – 100) mg/l"}],"search_zh":"水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a83b017af14b9c0e7b206d9","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(39 – 135) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (39 – 135) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11","norm_bases":["PN-N 01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres (39 – 135) dB\nMetoda pomiarowa bezpośrednia PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres (39 – 135) dB\nMetoda pomiarowa bezposrednia PN-N 01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie pomiarowa 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(39 – 135) dB"}],"search_en":"Workplace environment – noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(39 – 135) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b017af14b9c0e7b206da","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Szczytowy poziom dźwięku C","parameters":[{"name":"Zakres","range":"(39 – 138) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Szczytowy poziom dźwięku C\nZakres (39 – 138) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11","norm_bases":["PN-N 01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Szczytowy poziom dźwięku C\nZakres (39 – 138) dB\nMetoda pomiarowa bezpośrednia PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Szczytowy poziom dzwieku C\nZakres (39 – 138) dB\nMetoda pomiarowa bezposrednia PN-N 01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie pomiarowa 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"C-weighted peak sound pressure level","parameters_en":[{"name":"Range","range":"(39 – 138) dB"}],"search_en":"Workplace environment – noise C-weighted peak sound pressure level Direct measurement method Range PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment – noise","methodology_zh":"C 计权峰值声级","parameters_zh":[{"name":"范围","range":"(39 – 138) dB"}],"search_zh":"工作场所环境 — 噪声 C 计权峰值声级 直接测量法 范围 PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b017af14b9c0e7b206db","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Środowisko pracy – hałas","methodology":"Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy; - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy; - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11","norm_bases":["PN-N 01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – hałas Poziom ekspozycji na hałas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy; - przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11 Srodowisko pracy – halas Poziom ekspozycji na halas odniesiony do: - 8-godz. dobowego wymiaru czasu pracy; - przecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N 01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie pomiarowa 2 i 3 - punkt 10 i 11","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Workplace environment – noise PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11","test_object_en":"Workplace environment – noise","search_zh":"工作场所环境 — 噪声 PN-N 01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię pomiarową 2 i 3 - punkt 10 i 11","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a83b017af14b9c0e7b206dc","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(10 – 2000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (10 – 2000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (10 – 2000) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (10 – 2000) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(10 – 2000) lx"}],"search_en":"Workplace environment – indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(10 – 2000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b017af14b9c0e7b206dd","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Środowisko pracy – oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy – oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy – oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment – indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment – indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a83b017af14b9c0e7b206de","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Stal","methodology":"Zawartość węgla","parameters":[{"name":"Zakres","range":"(0,0007 – 0,0900) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla\nZakres (0,0007 – 0,0900) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 9556:2003","norm_bases":["PN-EN ISO 9556:2003"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stal Zawartość węgla\nZakres (0,0007 – 0,0900) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 9556:2003 Stal Zawartosc wegla\nZakres (0,0007 – 0,0900) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 9556:2003","categories":["materials"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Carbon content","parameters_en":[{"name":"Range","range":"(0,0007 – 0,0900) %"}],"search_en":"Steel Carbon content High-temperature combustion with IR detection Range PN-EN ISO 9556:2003","technique_en":"High-temperature combustion with IR detection","test_object_en":"Steel","parameters_zh":[{"name":"范围","range":"(0,0007 – 0,0900) %"}],"search_zh":"钢 碳含量 高温燃烧红外检测法 范围 PN-EN ISO 9556:2003","technique_zh":"高温燃烧红外检测法","methodology_zh":"碳含量","test_object_zh":"钢"},{"_id":"6a83b017af14b9c0e7b206df","lab_id":"69ad52a3de79e566650fb408","country":"PL","accr_number":"AB 801","accr_body":"PCA","test_object":"Stal","methodology":"Zawartość siarki","parameters":[{"name":"Zakres","range":"(0,0007 – 0,0300) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki\nZakres (0,0007 – 0,0300) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 24935:1994","norm_bases":["PN-EN 24935:1994"],"lab_section":"Laboratorium Centralne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Stal Zawartość siarki\nZakres (0,0007 – 0,0300) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 24935:1994 Stal Zawartosc siarki\nZakres (0,0007 – 0,0300) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 24935:1994","categories":["materials"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur content","parameters_en":[{"name":"Range","range":"(0,0007 – 0,0300) %"}],"search_en":"Steel Sulfur content High-temperature combustion with IR detection Range PN-EN 24935:1994","technique_en":"High-temperature combustion with IR detection","test_object_en":"Steel","parameters_zh":[{"name":"范围","range":"(0,0007 – 0,0300) %"}],"search_zh":"钢 硫含量 高温燃烧红外检测法 范围 PN-EN 24935:1994","technique_zh":"高温燃烧红外检测法","methodology_zh":"硫含量","test_object_zh":"钢"}],"has_pdf":true}