🇵🇱 GRUPA AZOTY S.A. PL

PCA AB 790 • Tarnów, Poland • 24 methods

Water & wastewaterPetrochemistry & fuels

GRUPA AZOTY S.A. is a laboratory accredited by PCA under number AB 790 (Tarnów, Poland). Its accreditation scope covers 24 test methods in the following areas: Water & wastewater, Petrochemistry & fuels. Test objects include: Water, Wastewater, Solid fuels - hard coal, Waste code: 10 01 02, 10 01 15, Wastewater. Most frequently used techniques: Spectrophotometric method, Gravimetric method, High-temperature combustion with IR detection.

At a glance

  • Accreditation number: PCA AB 790
  • Methods in scope: 24
  • Types of test objects: 5
  • Techniques used: 10
  • City: Tarnów, Poland
Accreditation number
AB 790
Accreditation body
PCA
Address
CENTRUM BADAŃ I ANALIZ, ul. Kwiatkowskiego 8, 33-101 Tarnów
City
Tarnów, Poland

What this laboratory tests (5)

Analytical techniques used (10)

Accreditation scope — test methods (24)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, Wastewater Mercury Hg concentration
Range (0,10 – 20,0) μg/l
Cold vapour atomic absorption spectrometry (CVAAS) PN-EN ISO 12846:2012 p.7 +Ap1:2016-07
2 Water, Wastewater Element concentration
Zn (0,020 – 5,0) mg/l Cd (0,020 – 5,0) mg/l Cu (0,020 – 5,0) mg/l Cr (0,003 – 5,0) mg/l Ni (0,005 – 5,0) mg/l Fe (0,005 – 50,0) mg/l V (0,005 – 5,0) mg/l Ag (0,005 – 5,0) mg/l As (0,050 – 5,0) mg/l Pb (0,050 – 5,0) mg/l Ba (0,050 – 5,0) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
3 Water, Wastewater Sulfide concentration
Range (0,10 – 20,0) mg/l
Spectrophotometric method PB 89/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 653
4 Water, Wastewater Adsorbable organically bound halogens (AOX) concentration
Range (0,05 – 10,0) mg/l
Spectrophotometric method PB 201/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 390
5 Solid fuels - hard coal Total moisture content
Range (1,0 – 18,0) %
Gravimetric method PN-G-04611:2020-06
6 Solid fuels - hard coal Moisture content in the analytical sample
Range (0,5 – 8,0) %
Gravimetric method PN-G-04611:2020-06
7 Solid fuels - hard coal Ash content
Range (1,0 – 40,0) %
Gravimetric method PN-ISO 1171:2002
8 Solid fuels - hard coal Total carbon content
Range (40,0 – 85,0) %
High-temperature combustion with IR detection PN-G-04571:1998
9 Solid fuels - hard coal Total hydrogen content
Range (1,40 – 5,50) %
High-temperature combustion with IR detection PN-G-04571:1998
10 Solid fuels - hard coal Total sulfur content
Range (0,20 – 1,20) %
High-temperature combustion with IR detection PN-G-04584:2001
11 Solid fuels - hard coal Gross calorific value
Range (15000 – 33000) kJ/kg Net calorific value (calculated)
Calorimetric method PN-ISO 1928:2020-05
12 Waste code: 10 01 02, 10 01 15 Total carbon content
Range (0,1 – 30,0) %
High-temperature combustion with IR detection PN-G-04571:1998
13 Water Sampling for chemical and physical testing Temperature of water/of the water sample taken
Range (1,0 – 50,0) °C
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.4, 7.5, 7.6; 9.2, 9.3, 9.4 | PN-77/C-04584
14 Wastewater Sampling for chemical and physical testing
Temperature of wastewater/of the collected wastewater sample Range (1,0 – 50,0) °C
Automatic method; Manual method PN-ISO 5667-10:2021-11 | PN-77/C-04584
15 Water, Wastewater pH
Range (4,0 – 10,0)
Potentiometric method PN-EN ISO 10523:2012
16 Water, Wastewater Anion concentrations
Chlorides (1,0 – 1000) mg/l Nitrates (1,0 – 220) mg/l Sulfates (10,0 – 800) mg/l Fluorides (0,10 – 20) mg/l Nitrate nitrogen (calculated)
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
17 Water, Wastewater Chemical oxygen demand
COD-Cr Range (10,0 – 150) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
18 Water, Wastewater Total suspended solids (TSS)
Range (0,80 – 100) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
19 Water, Wastewater Total phosphorus concentration
Range (0,080 – 3,00) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010
20 Water, Wastewater Phenol index
Range (0,004 – 0,1) mg/l
Spectrophotometric method PN-ISO 6439:1994 p. 5
21 Water, Wastewater Biochemical oxygen demand
BOD5 Range (1 – 30) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
22 Water, Wastewater Formaldehyde concentration
Range (0,10 – 2,0) mg/l
Spectrophotometric method PB 102/LKE wyd. III z dnia 08.09.2022
23 Water, Wastewater Substances extractable with petroleum ether
Range (1 – 100) mg/l
Gravimetric method PB 101/LKE wyd. IV z dnia 08.09.2022
24 Water, Wastewater Ammonium nitrogen concentration
Range (0,025 – 20,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002

Reference standards (22)

PB 101/LKE wyd. IV z dnia 08.09.2022
PB 102/LKE wyd. III z dnia 08.09.2022
PB 201/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 390
PB 89/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 653
PN-77/C-04584
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10523:2012
PN-EN ISO 11885:2009
PN-EN ISO 12846:2012 p.7 +Ap1:2016-07
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.4, 7.5, 7.6; 9.2, 9.3, 9.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010
PN-G-04571:1998
PN-G-04584:2001
PN-G-04611:2020-06
PN-ISO 1171:2002
PN-ISO 15705:2005
PN-ISO 1928:2020-05
PN-ISO 5667-10:2021-11
PN-ISO 6439:1994 p. 5
PN-ISO 7150-1:2002