{"lab":{"_id":"69ad52a3de79e566650fb3fa","accr_number":"AB 790","country":"PL","accr_body":"PCA","address":"CENTRUM BADAŃ I ANALIZ, ul. Kwiatkowskiego 8, 33-101 Tarnów","categories":["water","petro"],"city":"Tarnów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":24,"name":"GRUPA AZOTY S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_790.pdf"],"scope_summary":"","search_text":"grupa azoty s.a. centrum badań i analiz, ul. kwiatkowskiego 8, 33-101 tarnów water other environment petro pharma","status":"active","updated_at":"2026-03-08T14:51:40.649Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:40.649Z","location":{"type":"Point","coordinates":[20.9858,50.0121]},"email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20790,podmiot.html","fields_of_testing":[{"codes":"C/10; C/32","pl":"Badania chemiczne paliw stałych, odpadów","en":"Chemical tests of solid fuels, plastic products, waste"},{"codes":"C/28/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych","en":"Tests of physical properties of solid fuels"},{"codes":"N/28/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków","en":"Tests of physical properties and sampling of water, sewage"}],"issue":{"no":"21","date":"19.12.2025"},"parse_date":"2026-07-20T07:09:50.663Z","parse_source":"script-pdfplumber","map_coord":[50.014598,20.920583],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":16,"petro":7,"environment":1},"category_scores":{"water":10.67,"petro":2.04,"environment":0.04},"has_zh":true},"methods":[{"_id":"6a5dc9bef1c10c8ce825eb13","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie rtęci Hg","methodology_en":"Mercury Hg concentration","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 20,0) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)"],"technique_en":"Cold vapour atomic absorption spectrometry (CVAAS)","computed":[],"computed_en":[],"activity":"Stężenie rtęci Hg\nZakres (0,10 – 20,0) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS)","reference":"PN-EN ISO 12846:2012 p.7 +Ap1:2016-07","norm_bases":["PN-EN ISO 12846:2012 p.7 +Ap1:2016-07"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie rtęci Hg\nZakres (0,10 – 20,0) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 p.7 +Ap1:2016-07 Woda, Scieki Stezenie rteci Hg\nZakres (0,10 – 20,0) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CVAAS) PN-EN ISO 12846:2012 p.7 +Ap1:2016-07","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Mercury Hg concentration Cold vapour atomic absorption spectrometry (CVAAS) Range PN-EN ISO 12846:2012 p.7 +Ap1:2016-07","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) μg/l"}],"search_zh":"水、污水 冷蒸气原子吸收光谱法（CVAAS） 范围 PN-EN ISO 12846:2012 p.7 +Ap1:2016-07","technique_zh":"冷蒸气原子吸收光谱法（CVAAS）","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825eb14","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"Zn","range":"(0,020 – 5,0) mg/l"},{"name":"Cd","range":"(0,020 – 5,0) mg/l"},{"name":"Cu","range":"(0,020 – 5,0) mg/l"},{"name":"Cr","range":"(0,003 – 5,0) mg/l"},{"name":"Ni","range":"(0,005 – 5,0) mg/l"},{"name":"Fe","range":"(0,005 – 50,0) mg/l"},{"name":"V","range":"(0,005 – 5,0) mg/l"},{"name":"Ag","range":"(0,005 – 5,0) mg/l"},{"name":"As","range":"(0,050 – 5,0) mg/l"},{"name":"Pb","range":"(0,050 – 5,0) mg/l"},{"name":"Ba","range":"(0,050 – 5,0) mg/l"}],"parameters_en":[{"name":"Zn","range":"(0,020 – 5,0) mg/l"},{"name":"Cd","range":"(0,020 – 5,0) mg/l"},{"name":"Cu","range":"(0,020 – 5,0) mg/l"},{"name":"Cr","range":"(0,003 – 5,0) mg/l"},{"name":"Ni","range":"(0,005 – 5,0) mg/l"},{"name":"Fe","range":"(0,005 – 50,0) mg/l"},{"name":"V","range":"(0,005 – 5,0) mg/l"},{"name":"Ag","range":"(0,005 – 5,0) mg/l"},{"name":"As","range":"(0,050 – 5,0) mg/l"},{"name":"Pb","range":"(0,050 – 5,0) mg/l"},{"name":"Ba","range":"(0,050 – 5,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nZn (0,020 – 5,0) mg/l\nCd (0,020 – 5,0) mg/l\nCu (0,020 – 5,0) mg/l\nCr (0,003 – 5,0) mg/l\nNi (0,005 – 5,0) mg/l\nFe (0,005 – 50,0) mg/l\nV (0,005 – 5,0) mg/l\nAg (0,005 – 5,0) mg/l\nAs (0,050 – 5,0) mg/l\nPb (0,050 – 5,0) mg/l\nBa (0,050 – 5,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie pierwiastków\nZakres:\nZn (0,020 – 5,0) mg/l\nCd (0,020 – 5,0) mg/l\nCu (0,020 – 5,0) mg/l\nCr (0,003 – 5,0) mg/l\nNi (0,005 – 5,0) mg/l\nFe (0,005 – 50,0) mg/l\nV (0,005 – 5,0) mg/l\nAg (0,005 – 5,0) mg/l\nAs (0,050 – 5,0) mg/l\nPb (0,050 – 5,0) mg/l\nBa (0,050 – 5,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, Scieki Stezenie pierwiastkow\nZakres:\nZn (0,020 – 5,0) mg/l\nCd (0,020 – 5,0) mg/l\nCu (0,020 – 5,0) mg/l\nCr (0,003 – 5,0) mg/l\nNi (0,005 – 5,0) mg/l\nFe (0,005 – 50,0) mg/l\nV (0,005 – 5,0) mg/l\nAg (0,005 – 5,0) mg/l\nAs (0,050 – 5,0) mg/l\nPb (0,050 – 5,0) mg/l\nBa (0,050 – 5,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Zn Cd Cu Cr Ni Fe V Ag As Pb Ba PN-EN ISO 11885:2009","methodology_zh":"元素浓度","parameters_zh":[{"name":"Zn","range":"(0,020 – 5,0) mg/l"},{"name":"Cd","range":"(0,020 – 5,0) mg/l"},{"name":"Cu","range":"(0,020 – 5,0) mg/l"},{"name":"Cr","range":"(0,003 – 5,0) mg/l"},{"name":"Ni","range":"(0,005 – 5,0) mg/l"},{"name":"Fe","range":"(0,005 – 50,0) mg/l"},{"name":"V","range":"(0,005 – 5,0) mg/l"},{"name":"Ag","range":"(0,005 – 5,0) mg/l"},{"name":"As","range":"(0,050 – 5,0) mg/l"},{"name":"Pb","range":"(0,050 – 5,0) mg/l"},{"name":"Ba","range":"(0,050 – 5,0) mg/l"}],"search_zh":"水、污水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） Zn Cd Cu Cr Ni Fe V Ag As Pb Ba PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825eb15","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczków","methodology_en":"Sulfide concentration","parameters":[{"name":"Zakres","range":"(0,10 – 20,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczków\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PB 89/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 653","norm_bases":["PB 89/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 653"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczków\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna PB 89/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 653 Woda, Scieki Stezenie siarczkow\nZakres (0,10 – 20,0) mg/l\nMetoda spektrofotometryczna PB 89/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 653","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sulfide concentration Spectrophotometric method Range PB 89/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 653","parameters_zh":[{"name":"范围","range":"(0,10 – 20,0) mg/l"}],"search_zh":"水、污水 硫化物浓度 分光光度法 范围 PB 89/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 653","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"硫化物浓度"},{"_id":"6a5dc9bef1c10c8ce825eb16","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie adsorbowalnych związków chloroorganicznych (AOX)","methodology_en":"Adsorbable organically bound halogens (AOX) concentration","parameters":[{"name":"Zakres","range":"(0,05 – 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie adsorbowalnych związków chloroorganicznych (AOX)\nZakres (0,05 – 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PB 201/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 390","norm_bases":["PB 201/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 390"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie adsorbowalnych związków chloroorganicznych (AOX)\nZakres (0,05 – 10,0) mg/l\nMetoda spektrofotometryczna PB 201/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 390 Woda, Scieki Stezenie adsorbowalnych zwiazkow chloroorganicznych (AOX)\nZakres (0,05 – 10,0) mg/l\nMetoda spektrofotometryczna PB 201/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 390","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Adsorbable organically bound halogens (AOX) concentration Spectrophotometric method Range PB 201/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 390","parameters_zh":[{"name":"范围","range":"(0,05 – 10,0) mg/l"}],"search_zh":"水、污水 可吸附有机卤化物（AOX）浓度 分光光度法 范围 PB 201/LKS wyd. II z dnia 15.11.2023 na podstawie testu HACH Lange nr LCK 390","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"可吸附有机卤化物（AOX）浓度"},{"_id":"6a5dc9bef1c10c8ce825eb17","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Paliwa stałe - węgiel kamienny","test_object_en":"Solid fuels - hard coal","methodology":"Zawartość wilgoci całkowitej","methodology_en":"Total moisture content","parameters":[{"name":"Zakres","range":"(1,0 – 18,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 18,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci całkowitej\nZakres (1,0 – 18,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe - węgiel kamienny Zawartość wilgoci całkowitej\nZakres (1,0 – 18,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale - wegiel kamienny Zawartosc wilgoci calkowitej\nZakres (1,0 – 18,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels - hard coal Total moisture content Gravimetric method Range PN-G-04611:2020-06","methodology_zh":"全水分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 18,0) %"}],"search_zh":"固体燃料 — 烟煤 全水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料 — 烟煤"},{"_id":"6a5dc9bef1c10c8ce825eb18","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Paliwa stałe - węgiel kamienny","test_object_en":"Solid fuels - hard coal","methodology":"Zawartość wilgoci w próbce analitycznej","methodology_en":"Moisture content in the analytical sample","parameters":[{"name":"Zakres","range":"(0,5 – 8,0) %"}],"parameters_en":[{"name":"Range","range":"(0,5 – 8,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 8,0) %\nMetoda wagowa","reference":"PN-G-04611:2020-06","norm_bases":["PN-G-04611:2020-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe - węgiel kamienny Zawartość wilgoci w próbce analitycznej\nZakres (0,5 – 8,0) %\nMetoda wagowa PN-G-04611:2020-06 Paliwa stale - wegiel kamienny Zawartosc wilgoci w probce analitycznej\nZakres (0,5 – 8,0) %\nMetoda wagowa PN-G-04611:2020-06","categories":["petro"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels - hard coal Moisture content in the analytical sample Gravimetric method Range PN-G-04611:2020-06","methodology_zh":"分析样品水分含量","parameters_zh":[{"name":"范围","range":"(0,5 – 8,0) %"}],"search_zh":"固体燃料 — 烟煤 分析样品水分含量 重量法 范围 PN-G-04611:2020-06","technique_zh":"重量法","test_object_zh":"固体燃料 — 烟煤"},{"_id":"6a5dc9bef1c10c8ce825eb19","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Paliwa stałe - węgiel kamienny","test_object_en":"Solid fuels - hard coal","methodology":"Zawartość popiołu","methodology_en":"Ash content","parameters":[{"name":"Zakres","range":"(1,0 – 40,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 40,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość popiołu\nZakres (1,0 – 40,0) %\nMetoda wagowa","reference":"PN-ISO 1171:2002","norm_bases":["PN-ISO 1171:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe - węgiel kamienny Zawartość popiołu\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-ISO 1171:2002 Paliwa stale - wegiel kamienny Zawartosc popiolu\nZakres (1,0 – 40,0) %\nMetoda wagowa PN-ISO 1171:2002","categories":["petro"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels - hard coal Ash content Gravimetric method Range PN-ISO 1171:2002","methodology_zh":"灰分含量","parameters_zh":[{"name":"范围","range":"(1,0 – 40,0) %"}],"search_zh":"固体燃料 — 烟煤 灰分含量 重量法 范围 PN-ISO 1171:2002","technique_zh":"重量法","test_object_zh":"固体燃料 — 烟煤"},{"_id":"6a5dc9bef1c10c8ce825eb1a","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Paliwa stałe - węgiel kamienny","test_object_en":"Solid fuels - hard coal","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(40,0 – 85,0) %"}],"parameters_en":[{"name":"Range","range":"(40,0 – 85,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (40,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe - węgiel kamienny Zawartość węgla całkowitego\nZakres (40,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale - wegiel kamienny Zawartosc wegla calkowitego\nZakres (40,0 – 85,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels - hard coal Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(40,0 – 85,0) %"}],"search_zh":"固体燃料 — 烟煤 总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料 — 烟煤"},{"_id":"6a5dc9bef1c10c8ce825eb1b","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Paliwa stałe - węgiel kamienny","test_object_en":"Solid fuels - hard coal","methodology":"Zawartość wodoru całkowitego","methodology_en":"Total hydrogen content","parameters":[{"name":"Zakres","range":"(1,40 – 5,50) %"}],"parameters_en":[{"name":"Range","range":"(1,40 – 5,50) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość wodoru całkowitego\nZakres (1,40 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe - węgiel kamienny Zawartość wodoru całkowitego\nZakres (1,40 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Paliwa stale - wegiel kamienny Zawartosc wodoru calkowitego\nZakres (1,40 – 5,50) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["petro"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels - hard coal Total hydrogen content High-temperature combustion with IR detection Range PN-G-04571:1998","parameters_zh":[{"name":"范围","range":"(1,40 – 5,50) %"}],"search_zh":"固体燃料 — 烟煤 全氢含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料 — 烟煤","methodology_zh":"全氢含量"},{"_id":"6a5dc9bef1c10c8ce825eb1c","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Paliwa stałe - węgiel kamienny","test_object_en":"Solid fuels - hard coal","methodology":"Zawartość siarki całkowitej","methodology_en":"Total sulfur content","parameters":[{"name":"Zakres","range":"(0,20 – 1,20) %"}],"parameters_en":[{"name":"Range","range":"(0,20 – 1,20) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość siarki całkowitej\nZakres (0,20 – 1,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584:2001","norm_bases":["PN-G-04584:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe - węgiel kamienny Zawartość siarki całkowitej\nZakres (0,20 – 1,20) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584:2001 Paliwa stale - wegiel kamienny Zawartosc siarki calkowitej\nZakres (0,20 – 1,20) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584:2001","categories":["petro"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels - hard coal Total sulfur content High-temperature combustion with IR detection Range PN-G-04584:2001","methodology_zh":"全硫含量","parameters_zh":[{"name":"范围","range":"(0,20 – 1,20) %"}],"search_zh":"固体燃料 — 烟煤 全硫含量 高温燃烧红外检测法 范围 PN-G-04584:2001","technique_zh":"高温燃烧红外检测法","test_object_zh":"固体燃料 — 烟煤"},{"_id":"6a5dc9bef1c10c8ce825eb1d","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Paliwa stałe - węgiel kamienny","test_object_en":"Solid fuels - hard coal","methodology":"Ciepło spalania","methodology_en":"Gross calorific value","parameters":[{"name":"Zakres","range":"(15000 – 33000) kJ/kg"},{"name":"Wartość opałowa (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(15000 – 33000) kJ/kg"},{"name":"Net calorific value (calculated)"}],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"technique_en":"Calorimetric method","computed":[],"computed_en":[],"activity":"Ciepło spalania\nZakres:\nZakres (15000 – 33000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna","reference":"PN-ISO 1928:2020-05","norm_bases":["PN-ISO 1928:2020-05"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Paliwa stałe - węgiel kamienny Ciepło spalania\nZakres:\nZakres (15000 – 33000) kJ/kg\nWartość opałowa (z obliczeń)\nMetoda kalorymetryczna PN-ISO 1928:2020-05 Paliwa stale - wegiel kamienny Cieplo spalania\nZakres:\nZakres (15000 – 33000) kJ/kg\nWartosc opalowa (z obliczen)\nMetoda kalorymetryczna PN-ISO 1928:2020-05","categories":["petro"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Solid fuels - hard coal Gross calorific value Calorimetric method Range Net calorific value (calculated) PN-ISO 1928:2020-05","methodology_zh":"高位发热量","parameters_zh":[{"name":"范围","range":"(15000 – 33000) kJ/kg"},{"name":"低位发热量（计算值）"}],"search_zh":"固体燃料 — 烟煤 高位发热量 量热法 范围 低位发热量（计算值） PN-ISO 1928:2020-05","technique_zh":"量热法","test_object_zh":"固体燃料 — 烟煤"},{"_id":"6a5dc9bef1c10c8ce825eb1e","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Odpady kod: 10 01 02, 10 01 15","test_object_en":"Waste code: 10 01 02, 10 01 15","methodology":"Zawartość węgla całkowitego","methodology_en":"Total carbon content","parameters":[{"name":"Zakres","range":"(0,1 – 30,0) %"}],"parameters_en":[{"name":"Range","range":"(0,1 – 30,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"technique_en":"High-temperature combustion with IR detection","computed":[],"computed_en":[],"activity":"Zawartość węgla całkowitego\nZakres (0,1 – 30,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571:1998","norm_bases":["PN-G-04571:1998"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady kod: 10 01 02, 10 01 15 Zawartość węgla całkowitego\nZakres (0,1 – 30,0) %\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571:1998 Odpady kod: 10 01 02, 10 01 15 Zawartosc wegla calkowitego\nZakres (0,1 – 30,0) %\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571:1998","categories":["environment"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste code: 10 01 02, 10 01 15 Total carbon content High-temperature combustion with IR detection Range PN-G-04571:1998","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(0,1 – 30,0) %"}],"search_zh":"总碳含量 高温燃烧红外检测法 范围 PN-G-04571:1998","technique_zh":"高温燃烧红外检测法"},{"_id":"6a5dc9bef1c10c8ce825eb1f","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody","methodology_en":"Sampling for chemical and physical testing Temperature of water/of the water sample taken","parameters":[{"name":"Zakres","range":"(1,0 – 50,0) °C"}],"parameters_en":[{"name":"Range","range":"(1,0 – 50,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody\nZakres (1,0 – 50,0) °C","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.4, 7.5, 7.6; 9.2, 9.3, 9.4 | PN-77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.4, 7.5, 7.6; 9.2, 9.3, 9.4","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura wody/pobranej próbki wody\nZakres (1,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.4, 7.5, 7.6; 9.2, 9.3, 9.4 | PN-77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura wody/pobranej probki wody\nZakres (1,0 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.3, 7.4, 7.5, 7.6; 9.2, 9.3, 9.4 | PN-77/C-04584","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Temperature of water/of the water sample taken Range PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.4, 7.5, 7.6; 9.2, 9.3, 9.4 | PN-77/C-04584","parameters_zh":[{"name":"范围","range":"(1,0 – 50,0) °C"}],"search_zh":"水 用于化学与物理检验的采样 水/所采水样的温度 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.3, 7.4, 7.5, 7.6; 9.2, 9.3, 9.4 | PN-77/C-04584","test_object_zh":"水","methodology_zh":"用于化学与物理检验的采样 水/所采水样的温度"},{"_id":"6a5dc9bef1c10c8ce825eb20","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura ścieku/pobranej próbki ścieku"},{"name":"Zakres","range":"(1,0 – 50,0) °C"}],"parameters_en":[{"name":"Temperature of wastewater/of the collected wastewater sample"},{"name":"Range","range":"(1,0 – 50,0) °C"}],"technique":"Metoda automatyczna; Metoda manualna","techniques":["Metoda automatyczna","Metoda manualna"],"technique_en":"Automatic method; Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieku/pobranej próbki ścieku\nZakres (1,0 – 50,0) °C\nMetoda automatyczna; Metoda manualna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieku/pobranej próbki ścieku\nZakres (1,0 – 50,0) °C\nMetoda automatyczna; Metoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura scieku/pobranej probki scieku\nZakres (1,0 – 50,0) °C\nMetoda automatyczna; Metoda manualna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Automatic method; Manual method Temperature of wastewater/of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"Temperatura ścieku/pobranej próbki ścieku"},{"name":"范围","range":"(1,0 – 50,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 自动法；手工法 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"自动法；手工法"},{"_id":"6a5dc9bef1c10c8ce825eb21","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"(4,0 – 10,0)"}],"parameters_en":[{"name":"Range","range":"(4,0 – 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 – 10,0)"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825eb22","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"Chlorki","range":"(1,0 – 1000) mg/l"},{"name":"Azotany","range":"(1,0 – 220) mg/l"},{"name":"Siarczany","range":"(10,0 – 800) mg/l"},{"name":"Fluorki","range":"(0,10 – 20) mg/l"},{"name":"Azot azotanowy (z obliczeń)"}],"parameters_en":[{"name":"Chlorides","range":"(1,0 – 1000) mg/l"},{"name":"Nitrates","range":"(1,0 – 220) mg/l"},{"name":"Sulfates","range":"(10,0 – 800) mg/l"},{"name":"Fluorides","range":"(0,10 – 20) mg/l"},{"name":"Nitrate nitrogen (calculated)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nChlorki (1,0 – 1000) mg/l\nAzotany (1,0 – 220) mg/l\nSiarczany (10,0 – 800) mg/l\nFluorki (0,10 – 20) mg/l\nAzot azotanowy (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie anionów\nZakres:\nChlorki (1,0 – 1000) mg/l\nAzotany (1,0 – 220) mg/l\nSiarczany (10,0 – 800) mg/l\nFluorki (0,10 – 20) mg/l\nAzot azotanowy (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda, Scieki Stezenie anionow\nZakres:\nChlorki (1,0 – 1000) mg/l\nAzotany (1,0 – 220) mg/l\nSiarczany (10,0 – 800) mg/l\nFluorki (0,10 – 20) mg/l\nAzot azotanowy (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Anion concentrations Ion chromatography with conductometric detection (IC-CD) Chlorides Nitrates Sulfates Fluorides Nitrate nitrogen (calculated) PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氯化物","range":"(1,0 – 1000) mg/l"},{"name":"硝酸盐","range":"(1,0 – 220) mg/l"},{"name":"硫酸盐","range":"(10,0 – 800) mg/l"},{"name":"氟化物","range":"(0,10 – 20) mg/l"},{"name":"Azot azotanowy (z obliczeń)"}],"search_zh":"水、污水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 硝酸盐 硫酸盐 氟化物 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825eb23","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(10,0 – 150) mg/l O2"}],"parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(10,0 – 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT-Cr\nZakres (10,0 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chemical oxygen demand Spectrophotometric method COD-Cr Range PN-ISO 15705:2005","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(10,0 – 150) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD） 分光光度法 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9bef1c10c8ce825eb24","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(0,80 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,80 – 100) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (0,80 – 100) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (0,80 – 100) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (0,80 – 100) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(0,80 – 100) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825eb25","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,080 – 3,00) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,080 – 3,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,080 – 3,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,080 – 3,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,080 – 3,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,080 – 3,00) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825eb26","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,004 – 0,1) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,004 – 0,1) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,004 – 0,1) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 p. 5","norm_bases":["PN-ISO 6439:1994 p. 5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,004 – 0,1) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 p. 5 Woda, Scieki Indeks fenolowy\nZakres (0,004 – 0,1) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 p. 5","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994 p. 5","parameters_zh":[{"name":"范围","range":"(0,004 – 0,1) mg/l"}],"search_zh":"水、污水 酚指数 分光光度法 范围 PN-ISO 6439:1994 p. 5","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"酚指数"},{"_id":"6a5dc9bef1c10c8ce825eb27","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1 – 30) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1 – 30) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 30) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 30) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 30) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1 – 30) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825eb28","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie aldehydu mrówkowego","methodology_en":"Formaldehyde concentration","parameters":[{"name":"Zakres","range":"(0,10 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie aldehydu mrówkowego\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PB 102/LKE wyd. III z dnia 08.09.2022","norm_bases":["PB 102/LKE wyd. III z dnia 08.09.2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie aldehydu mrówkowego\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna PB 102/LKE wyd. III z dnia 08.09.2022 Woda, Scieki Stezenie aldehydu mrowkowego\nZakres (0,10 – 2,0) mg/l\nMetoda spektrofotometryczna PB 102/LKE wyd. III z dnia 08.09.2022","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Formaldehyde concentration Spectrophotometric method Range PB 102/LKE wyd. III z dnia 08.09.2022","parameters_zh":[{"name":"范围","range":"(0,10 – 2,0) mg/l"}],"search_zh":"水、污水 甲醛浓度 分光光度法 范围 PB 102/LKE wyd. III z dnia 08.09.2022","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"甲醛浓度"},{"_id":"6a5dc9bef1c10c8ce825eb29","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Substancje ekstrahujące się eterem naftowym","methodology_en":"Substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(1 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(1 – 100) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Substancje ekstrahujące się eterem naftowym\nZakres (1 – 100) mg/l\nMetoda wagowa","reference":"PB 101/LKE wyd. IV z dnia 08.09.2022","norm_bases":["PB 101/LKE wyd. IV z dnia 08.09.2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Substancje ekstrahujące się eterem naftowym\nZakres (1 – 100) mg/l\nMetoda wagowa PB 101/LKE wyd. IV z dnia 08.09.2022 Woda, Scieki Substancje ekstrahujace sie eterem naftowym\nZakres (1 – 100) mg/l\nMetoda wagowa PB 101/LKE wyd. IV z dnia 08.09.2022","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Substances extractable with petroleum ether Gravimetric method Range PB 101/LKE wyd. IV z dnia 08.09.2022","parameters_zh":[{"name":"范围","range":"(1 – 100) mg/l"}],"search_zh":"水、污水 石油醚可萃取物 重量法 范围 PB 101/LKE wyd. IV z dnia 08.09.2022","technique_zh":"重量法","test_object_zh":"水、污水","methodology_zh":"石油醚可萃取物"},{"_id":"6a5dc9bef1c10c8ce825eb2a","lab_id":"69ad52a3de79e566650fb3fa","country":"PL","accr_number":"AB 790","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,025 – 20,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,025 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,025 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,025 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,025 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,025 – 20,0) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"}],"has_pdf":true}