🇵🇱 ARCTIC PAPER KOSTRZYN S.A. PL

PCA AB 785 • Kostrzyn nad Odrą, Poland • 25 methods

Water & wastewaterEnvironment

ARCTIC PAPER KOSTRZYN S.A. is a laboratory accredited by PCA under number AB 785 (Kostrzyn nad Odrą, Poland). Its accreditation scope covers 25 test methods in the following areas: Water & wastewater, Environment. Test objects include: Water, wastewater, Workplace environment - air, Workplace environment - hot microclimate, Workplace environment - indoor electric lighting. Most frequently used techniques: Spectrophotometric method, Direct measurement method, Electrochemical method.

At a glance

  • Accreditation number: PCA AB 785
  • Methods in scope: 25
  • Types of test objects: 7
  • Techniques used: 7
  • City: Kostrzyn nad Odrą, Poland
Accreditation number
AB 785
Accreditation body
PCA
Address
LABORATORIUM, ul. Fabryczna 1, 66-470 Kostrzyn nad Odrą
City
Kostrzyn nad Odrą, Poland

What this laboratory tests (7)

Analytical techniques used (7)

Accreditation scope — test methods (25)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (30,0 – 135,0) dB C-weighted peak sound pressure level Range (55,0 – 135,0) dB
Direct measurement method PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994
2 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994
3 Workplace environment - hot microclimate Air temperature
Range (10,0 – 50,0) °C Natural wet bulb temperature Range (0,0 – 50,0) °C Black globe temperature Range (10,0 – 50,0) °C
Direct measurement method PN-EN ISO 7243:2018-01
4 Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01
5 Workplace environment - air Sampling for the assessment of occupational exposure to:
dust agents inhalable fraction respirable fraction
Personal dosimetry method PN-Z-04008-7:2002
6 Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002
7 Workplace environment - air Concentration of harmful dust agents - inhalable fraction
Organic dusts of animal and plant origin, excluding wood and flour dusts Range (0,18 – 20,4) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
8 Workplace environment - air Concentration of dust harmful to health - respirable fraction
Organic dusts of animal and plant origin, excluding wood and flour dusts Range (0,12 – 12,6) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
9 Workplace environment - indoor electric lighting Illuminance
Range (5,0 – 5000) Ix
Direct measurement method PN-83/E-04040.03
10 Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
11 Surface water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 8.2; 9.4; 10.6
12 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
13 Water, wastewater Chemical oxygen demand
SP-COD Range (15,0 – 150) mg/l O2 Range (100 – 1000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
14 Water, wastewater Total phosphorus concentration
Range (0,05 – 1,5) mg/l
Spectrophotometric method Metoda HACH LANGE LCK 349 wydanie 6 z 07/2025
15 Water, wastewater Total phosphorus concentration
Range (0,5 – 5,0) mg/l
Spectrophotometric method Metoda HACH LANGE LCK 348 wydanie 5 z 06/2025
16 Water, wastewater Total nitrogen concentration
Range (1,0 – 16,0) mg/l
Spectrophotometric method Metoda HACH LANGE LCK 138 wydanie 4 z 04/2024
17 Water, wastewater Total nitrogen concentration
Range (5,0 – 40,0) mg/l
Spectrophotometric method Metoda HACH LANGE LCK 238 wydanie 4 z 04/2024
18 Water, wastewater Chloride concentration
Range (1,0 – 1000) mg/l
Spectrophotometric method Metoda HACH LANGE LCK 311 wydanie 3 z 04/2022
19 Water, wastewater Sulfate concentration
Range (40,0 – 150) mg/l
Spectrophotometric method Metoda HACH LANGE LCK 153 wydanie z 10/2019
20 Water, wastewater Sulfate concentration
Range (150 – 900) mg/l
Spectrophotometric method Metoda HACH LANGE LCK 353 wydanie z 10/2019
21 Water, wastewater Biochemical oxygen demand - BOD5
Range (0,5 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
22 Water, wastewater Biochemical oxygen demand - BOD5
Range (3,0 – 1000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
23 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
24 Water, wastewater pH
Range 4,0 – 10
Potentiometric method PN-EN ISO 10523:2012
25 Water, wastewater Dissolved oxygen concentration
Range (0,6 – 14,0) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04

Reference standards (24)

Metoda HACH LANGE LCK 138 wydanie 4 z 04/2024
Metoda HACH LANGE LCK 153 wydanie z 10/2019
Metoda HACH LANGE LCK 238 wydanie 4 z 04/2024
Metoda HACH LANGE LCK 311 wydanie 3 z 04/2022
Metoda HACH LANGE LCK 348 wydanie 5 z 06/2025
Metoda HACH LANGE LCK 349 wydanie 6 z 07/2025
Metoda HACH LANGE LCK 353 wydanie z 10/2019
PN-83/E-04040.03
PN-EN 1899-2:2002
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 8.2; 9.4; 10.6
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019-12
PN-EN ISO 7243:2018-01
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-N-01307:1994
PN-Z-04008-7:2002
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08