{"lab":{"_id":"69ad52a3de79e566650fb3f0","accr_number":"AB 785","country":"PL","accr_body":"PCA","address":"LABORATORIUM, ul. Fabryczna 1, 66-470 Kostrzyn nad Odrą","categories":["water","environment"],"city":"Kostrzyn nad Odrą","imported_at":"2026-03-08T10:42:43.265Z","methods_count":25,"name":"ARCTIC PAPER KOSTRZYN S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_785.pdf"],"scope_summary":"","search_text":"arctic paper kostrzyn s.a. laboratorium, ul. fabryczna 1, 66-470 kostrzyn nad odrą environment other pharma electronics metrology water","status":"active","updated_at":"2026-03-08T14:51:40.289Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:40.289Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20785,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków","en":"Chemical tests and sampling of water, sewage"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, mikroklimat, oświetlenie)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, microclimate, lighting)"},{"codes":"N/28/P; N/30/P","pl":"Badanie właściwości fizycznych i pobieranie próbek wody, ścieków","en":"Tests of physical properties and sampling of water, sewage"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe – powietrze","en":"Tests of physical properties and sampling - working environment (harmful factors – air)"}],"issue":{"no":"29","date":"22.01.2026"},"parse_date":"2026-07-20T07:09:50.562Z","parse_source":"script-pdfplumber","map_coord":[52.595181,14.62501],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":15,"environment":10},"category_scores":{"water":9,"environment":4},"has_zh":true},"methods":[{"_id":"6a5dc9bef1c10c8ce825ea98","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters":[{"name":"Zakres","range":"(30,0 – 135,0) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(55,0 – 135,0) dB"}],"parameters_en":[{"name":"Range","range":"(30,0 – 135,0) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(55,0 – 135,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (30,0 – 135,0) dB\nSzczytowy poziom dźwięku C\nZakres (55,0 – 135,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","norm_bases":["PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","PN-N-01307:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (30,0 – 135,0) dB\nSzczytowy poziom dźwięku C\nZakres (55,0 – 135,0) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (30,0 – 135,0) dB\nSzczytowy poziom dzwieku C\nZakres (55,0 – 135,0) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method Range C-weighted peak sound pressure level Range PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(30,0 – 135,0) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(55,0 – 135,0) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 范围 C 计权峰值声级 范围 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9bef1c10c8ce825ea99","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Środowisko pracy - hałas","test_object_en":"Workplace environment - noise","methodology":"Poziom ekspozycji na hałas odniesiony do:","methodology_en":"Noise exposure level referred to:","parameters":[{"name":"8-godz. dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","norm_bases":["PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11","PN-N-01307:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8-godz. dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - noise Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated) PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： 8 小时日工作时间 平均每周工作时间（计算值） PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 i 3 – punkt 10 i 11 | PN-N-01307:1994","test_object_zh":"工作场所环境 — 噪声"},{"_id":"6a5dc9bef1c10c8ce825ea9a","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","test_object_en":"Workplace environment - hot microclimate","methodology":"Temperatura powietrza","methodology_en":"Air temperature","parameters":[{"name":"Zakres","range":"(10,0 – 50,0) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(0,0 – 50,0) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(10,0 – 50,0) °C"}],"parameters_en":[{"name":"Range","range":"(10,0 – 50,0) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(0,0 – 50,0) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(10,0 – 50,0) °C"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Temperatura powietrza\nZakres:\nZakres (10,0 – 50,0) °C\nTemperatura wilgotna naturalna\nZakres (0,0 – 50,0) °C\nTemperatura poczernionej kuli\nZakres (10,0 – 50,0) °C\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (10,0 – 50,0) °C\nTemperatura wilgotna naturalna\nZakres (0,0 – 50,0) °C\nTemperatura poczernionej kuli\nZakres (10,0 – 50,0) °C\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (10,0 – 50,0) °C\nTemperatura wilgotna naturalna\nZakres (0,0 – 50,0) °C\nTemperatura poczernionej kuli\nZakres (10,0 – 50,0) °C\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method Range Natural wet bulb temperature Range Black globe temperature Range PN-EN ISO 7243:2018-01","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(10,0 – 50,0) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(0,0 – 50,0) °C"},{"name":"黑球温度"},{"name":"范围","range":"(10,0 – 50,0) °C"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 范围 自然湿球温度 范围 黑球温度 范围 PN-EN ISO 7243:2018-01","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a5dc9bef1c10c8ce825ea9b","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","test_object_en":"Workplace environment - hot microclimate","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","methodology_en":"WBGT index, WBGTeff index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01","norm_bases":["PN-EN ISO 7243:2018-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） PN-EN ISO 7243:2018-01","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a5dc9bef1c10c8ce825ea9c","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters":[{"name":"czynniki pyłowe"},{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"}],"parameters_en":[{"name":"dust agents"},{"name":"inhalable fraction"},{"name":"respirable fraction"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"technique_en":"Personal dosimetry method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002","norm_bases":["PN-Z-04008-7:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe\nfrakcja wdychalna\nfrakcja respirabilna\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002","categories":["environment"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method dust agents inhalable fraction respirable fraction PN-Z-04008-7:2002","methodology_zh":"职业接触评估采样，针对：","parameters_zh":[{"name":"粉尘因素"},{"name":"可吸入组分"},{"name":"呼吸性组分"}],"search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 粉尘因素 可吸入组分 呼吸性组分 PN-Z-04008-7:2002","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9bef1c10c8ce825ea9d","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Wskaźnik narażenia (z obliczeń)","methodology_en":"Exposure index (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002","norm_bases":["PN-Z-04008-7:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） PN-Z-04008-7:2002","test_object_zh":"工作场所环境 — 空气"},{"_id":"6a5dc9bef1c10c8ce825ea9e","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna","methodology_en":"Concentration of harmful dust agents - inhalable fraction","parameters":[{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,18 – 20,4) mg/m3"}],"parameters_en":[{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Range","range":"(0,18 – 20,4) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,18 – 20,4) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,18 – 20,4) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja wdychalna\nZakres:\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,18 – 20,4) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Concentration of harmful dust agents - inhalable fraction Gravimetric method Organic dusts of animal and plant origin, excluding wood and flour dusts Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","parameters_zh":[{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"范围","range":"(0,18 – 20,4) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 动植物来源有机粉尘，木粉和面粉除外 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a5dc9bef1c10c8ce825ea9f","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","test_object_en":"Workplace environment - air","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna","methodology_en":"Concentration of dust harmful to health - respirable fraction","parameters":[{"name":"Pyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki"},{"name":"Zakres","range":"(0,12 – 12,6) mg/m3"}],"parameters_en":[{"name":"Organic dusts of animal and plant origin, excluding wood and flour dusts"},{"name":"Range","range":"(0,12 – 12,6) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna\nZakres:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,12 – 12,6) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia - frakcja respirabilna\nZakres:\nPyły organiczne pochodzenia zwierzęcego i roślinnego z wyjątkiem pyłów drewna oraz mąki\nZakres (0,12 – 12,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia - frakcja respirabilna\nZakres:\nPyly organiczne pochodzenia zwierzecego i roslinnego z wyjatkiem pylow drewna oraz maki\nZakres (0,12 – 12,6) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - air Concentration of dust harmful to health - respirable fraction Gravimetric method Organic dusts of animal and plant origin, excluding wood and flour dusts Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","parameters_zh":[{"name":"动植物来源有机粉尘，木粉和面粉除外"},{"name":"范围","range":"(0,12 – 12,6) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 动植物来源有机粉尘，木粉和面粉除外 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a5dc9bef1c10c8ce825eaa0","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Natężenie oświetlenia","methodology_en":"Illuminance","parameters":[{"name":"Zakres","range":"(5,0 – 5000) Ix"}],"parameters_en":[{"name":"Range","range":"(5,0 – 5000) Ix"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie oświetlenia\nZakres (5,0 – 5000) Ix\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (5,0 – 5000) Ix\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (5,0 – 5000) Ix\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(5,0 – 5000) Ix"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5dc9bef1c10c8ce825eaa1","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","test_object_en":"Workplace environment - indoor electric lighting","methodology":"Równomierność oświetlenia (z obliczeń)","methodology_en":"Illuminance uniformity (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作场所环境 — 室内电气照明"},{"_id":"6a5dc9bef1c10c8ce825eaa2","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda powierzchniowa","test_object_en":"Surface water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 8.2; 9.4; 10.6","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 8.2; 9.4; 10.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 8.2; 9.4; 10.6 Woda powierzchniowa Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.2; 7.3; 7.5; 7.6; 8.2; 9.4; 10.6","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 8.2; 9.4; 10.6","methodology_zh":"化学与物理检测用样品采集","search_zh":"地表水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.2; 7.3; 7.5; 7.6; 8.2; 9.4; 10.6","test_object_zh":"地表水"},{"_id":"6a5dc9bef1c10c8ce825eaa3","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a5dc9bef1c10c8ce825eaa4","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"SP-ChZT"},{"name":"Zakres","range":"(15,0 – 150) mg/l O2"},{"name":"Zakres","range":"(100 – 1000) mg/l O2"}],"parameters_en":[{"name":"SP-COD"},{"name":"Range","range":"(15,0 – 150) mg/l O2"},{"name":"Range","range":"(100 – 1000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nSP-ChZT\nZakres (15,0 – 150) mg/l O2\nZakres (100 – 1000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nSP-ChZT\nZakres (15,0 – 150) mg/l O2\nZakres (100 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nSP-ChZT\nZakres (15,0 – 150) mg/l O2\nZakres (100 – 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chemical oxygen demand Spectrophotometric method SP-COD Range Range PN-ISO 15705:2005","parameters_zh":[{"name":"SP-ChZT"},{"name":"范围","range":"(15,0 – 150) mg/l O2"},{"name":"范围","range":"(100 – 1000) mg/l O2"}],"search_zh":"水、废水 化学需氧量（COD） 分光光度法 范围 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9bef1c10c8ce825eaa5","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,05 – 1,5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 1,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 1,5) mg/l\nMetoda spektrofotometryczna","reference":"Metoda HACH LANGE LCK 349 wydanie 6 z 07/2025","norm_bases":["Metoda HACH LANGE LCK 349 wydanie 6 z 07/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,05 – 1,5) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 349 wydanie 6 z 07/2025 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,05 – 1,5) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 349 wydanie 6 z 07/2025","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range Metoda HACH LANGE LCK 349 wydanie 6 z 07/2025","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 1,5) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 Metoda HACH LANGE LCK 349 wydanie 6 z 07/2025","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eaa6","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,5 – 5,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,5 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,5 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"Metoda HACH LANGE LCK 348 wydanie 5 z 06/2025","norm_bases":["Metoda HACH LANGE LCK 348 wydanie 5 z 06/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,5 – 5,0) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 348 wydanie 5 z 06/2025 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,5 – 5,0) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 348 wydanie 5 z 06/2025","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range Metoda HACH LANGE LCK 348 wydanie 5 z 06/2025","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 5,0) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 Metoda HACH LANGE LCK 348 wydanie 5 z 06/2025","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eaa7","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 16,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 16,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 16,0) mg/l\nMetoda spektrofotometryczna","reference":"Metoda HACH LANGE LCK 138 wydanie 4 z 04/2024","norm_bases":["Metoda HACH LANGE LCK 138 wydanie 4 z 04/2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego\nZakres (1,0 – 16,0) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 138 wydanie 4 z 04/2024 Woda, scieki Stezenie azotu ogolnego\nZakres (1,0 – 16,0) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 138 wydanie 4 z 04/2024","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration Spectrophotometric method Range Metoda HACH LANGE LCK 138 wydanie 4 z 04/2024","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 16,0) mg/l"}],"search_zh":"水、废水 总氮浓度 分光光度法 范围 Metoda HACH LANGE LCK 138 wydanie 4 z 04/2024","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eaa8","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(5,0 – 40,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 40,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (5,0 – 40,0) mg/l\nMetoda spektrofotometryczna","reference":"Metoda HACH LANGE LCK 238 wydanie 4 z 04/2024","norm_bases":["Metoda HACH LANGE LCK 238 wydanie 4 z 04/2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego\nZakres (5,0 – 40,0) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 238 wydanie 4 z 04/2024 Woda, scieki Stezenie azotu ogolnego\nZakres (5,0 – 40,0) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 238 wydanie 4 z 04/2024","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration Spectrophotometric method Range Metoda HACH LANGE LCK 238 wydanie 4 z 04/2024","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 40,0) mg/l"}],"search_zh":"水、废水 总氮浓度 分光光度法 范围 Metoda HACH LANGE LCK 238 wydanie 4 z 04/2024","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eaa9","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(1,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 1000) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (1,0 – 1000) mg/l\nMetoda spektrofotometryczna","reference":"Metoda HACH LANGE LCK 311 wydanie 3 z 04/2022","norm_bases":["Metoda HACH LANGE LCK 311 wydanie 3 z 04/2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (1,0 – 1000) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 311 wydanie 3 z 04/2022 Woda, scieki Stezenie chlorkow\nZakres (1,0 – 1000) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 311 wydanie 3 z 04/2022","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chloride concentration Spectrophotometric method Range Metoda HACH LANGE LCK 311 wydanie 3 z 04/2022","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 1000) mg/l"}],"search_zh":"水、废水 氯化物浓度 分光光度法 范围 Metoda HACH LANGE LCK 311 wydanie 3 z 04/2022","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eaaa","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(40,0 – 150) mg/l"}],"parameters_en":[{"name":"Range","range":"(40,0 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (40,0 – 150) mg/l\nMetoda spektrofotometryczna","reference":"Metoda HACH LANGE LCK 153 wydanie z 10/2019","norm_bases":["Metoda HACH LANGE LCK 153 wydanie z 10/2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (40,0 – 150) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 153 wydanie z 10/2019 Woda, scieki Stezenie siarczanow\nZakres (40,0 – 150) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 153 wydanie z 10/2019","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sulfate concentration Spectrophotometric method Range Metoda HACH LANGE LCK 153 wydanie z 10/2019","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(40,0 – 150) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 分光光度法 范围 Metoda HACH LANGE LCK 153 wydanie z 10/2019","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eaab","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(150 – 900) mg/l"}],"parameters_en":[{"name":"Range","range":"(150 – 900) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (150 – 900) mg/l\nMetoda spektrofotometryczna","reference":"Metoda HACH LANGE LCK 353 wydanie z 10/2019","norm_bases":["Metoda HACH LANGE LCK 353 wydanie z 10/2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczanów\nZakres (150 – 900) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 353 wydanie z 10/2019 Woda, scieki Stezenie siarczanow\nZakres (150 – 900) mg/l\nMetoda spektrofotometryczna Metoda HACH LANGE LCK 353 wydanie z 10/2019","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sulfate concentration Spectrophotometric method Range Metoda HACH LANGE LCK 353 wydanie z 10/2019","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(150 – 900) mg/l"}],"search_zh":"水、废水 硫酸盐浓度 分光光度法 范围 Metoda HACH LANGE LCK 353 wydanie z 10/2019","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eaac","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN 1899-2:2002","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9bef1c10c8ce825eaad","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(3,0 – 1000) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(3,0 – 1000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 1000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu - BZT5\nZakres (3,0 – 1000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3,0 – 1000) mg/l O2"}],"search_zh":"水、废水 五日生化需氧量（BOD5） 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"五日生化需氧量（BOD5）"},{"_id":"6a5dc9bef1c10c8ce825eaae","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eaaf","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10"}],"parameters_en":[{"name":"Range","range":"4,0 – 10"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki pH\nZakres 4,0 – 10\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 4,0 – 10\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a5dc9bef1c10c8ce825eab0","lab_id":"69ad52a3de79e566650fb3f0","country":"PL","accr_number":"AB 785","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,6 – 14,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,6 – 14,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,6 – 14,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,6 – 14,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (0,6 – 14,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","parameters_zh":[{"name":"范围","range":"(0,6 – 14,0) mg/l O2"}],"search_zh":"水、废水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"}],"has_pdf":true}