🇵🇱 WODOCIĄGI MIASTA KRAKOWA S.A. PL

PCA AB 776 • Kraków, Poland • 113 methods

Water & wastewaterMicrobiologyEnvironment

WODOCIĄGI MIASTA KRAKOWA S.A. is a laboratory accredited by PCA under number AB 776 (Kraków, Poland). Its accreditation scope covers 113 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Water, Wastewater, Water, Swimming pool water, Wastewater. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 776
  • Methods in scope: 113
  • Types of test objects: 14
  • Techniques used: 30
  • City: Kraków, Poland
Accreditation number
AB 776
Accreditation body
PCA
Address
ul. Senatorska 1, 30-106 Kraków, CENTRALNE LABORATORIUM, ul. Lindego 9, 30-148 Kraków
City
Kraków, Poland

What this laboratory tests (14)

Analytical techniques used (30)

Accreditation scope — test methods (113)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water Sampling for chemical and physical testing Temperature
Range (0,5 – 50,0) °C
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 9.4 | PN -77/C-04584
2 Water intended for human consumption Sampling for chemical and physical testing Temperature
Range (0,5 – 80,0)°C
PN-ISO 5667-5: 2017-10 | PN -77/C-04584
3 Swimming pool water Sampling for chemical and physical testing Temperature
Range (0,5 – 50,0) °C
IO-W-01 wydanie 1 z dnia 10.10.2024 r. | PN -77/C-04584
4 Water pH
Range 3,0 - 12,0
Potentiometric method PN-EN ISO 10523:2012
5 Water Electrical conductivity
Range (5,0 - 5000) μS/cm
Conductometric method PN-EN 27888:1999
6 Water Turbidity
Range (0,10 - 1000) NTU
Nephelometric method PN-EN ISO 7027-1:2016-04
7 Water Total content of calcium and magnesium (total hardness)
Range (11,0 - 800) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
8 Water Permanganate index
Range (0,7 - 10,0) mg/l
Titrimetric method PN-EN ISO 8467:2001
9 Water Total suspended solids (TSS)
Range (2,0 - 1000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
10 Water Anion concentrations
fluorides (0,014 - 1,00) mg/l chlorides (2,5 - 250) mg/l nitrites (0,010 - 0,5) mg/l nitrates (2,0 - 100) mg/l phosphates (0,020 - 1,0) mg/l) sulfates (5,0 - 250) mg/l
Ion chromatography with conductometric detection (IC-CD) PN EN ISO 10304-1:2009 +AC:2012
11 Water Colour
Range (1 - 40) mg/l Pt
Visual method PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7
12 Water Cation concentrations
sodium (4,0 - 100) mg/l ammonium ion (0,02 - 1) mg/l magnesium (2,0 - 50) mg/l calcium (5,0 - 120) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 14911:2002
13 Water Poly- and perfluoroalkyl acids (PFAS) concentration
perfluorobutanoic acid (PFBA) Range (0,0012-0,20) μg/l perfluoropentanoic acid (PFPA) (0,0012-0,20) μg/l perfluorohexanoic acid (PFHxA) (0,0012-0,20) μg/l perfluoroheptanoic acid (PFHpA) (0,0012-0,20) μg/l perfluorooctanoic acid (PFOA) (0,0012-0,20) μg/l perfluorononanoic acid (PFNA) (0,0012-0,20) μg/l perfluorodecanoic acid (PFDA) (0,0012-0,20) μg/l perfluoroundecanoic acid (PFUnDA) (0,0012-0,20) μg/l perfluorododecanoic acid (PFDoDA) (0,0012-0,20) μg/l perfluorotridecanoic acid (PFTrDA) (0,0012-0,20) μg/l perfluorobutanesulfonic acid (PF BS) (0,0012-0,20) μg/l perfluoropentanesulfonic acid (PFPS) (0,0012-0,20) μg/l perfluorohexanesulfonic acid (PFHxS) (0,0012-0,20) μg/l perfluoroheptanesulfonic acid (PFHpS) (0,0012-0,20) μg/l perfluorooctanesulfonic acid (PFOS) (0,0012-0,20) μg/l perfluorononanesulfonic acid (PFNS) (0,0012-0,20) μg/l perfluorodecanesulfonic acid (PFDS) (0,0012-0,20) μg/l perfluoroundecanesulfonic acid (0,0012-0,20) μg/l perfluorododecanesulfonic acid (0,0012-0,20) μg/l perfluorotridecanesulfonic acid (0,0012-0,20) μg/l Sum of PFAS (calculated)
Liquid chromatography with tandem mass spectrometry (LC-MS-MS) PB-W-39 wydanie 2 z dnia 04.10.2024 r.
14 Water Free cyanide concentration
Range (0,010 – 0,070) mg/l
Spectrophotometric method PB-S-52 wydanie 1 z dnia 01.06.2024 r. na podstawie testu kuwetowego HACH LCK 315
15 Water Bromate concentration
Range (2,5-100) μg/l
Liquid chromatography with tandem mass spectrometry (LC-MS-MS) PB-W-40 wydanie 1 z dnia 01. 10.2023 r.
16 Water Haloacetic acid (HAA) concentration
monochloroacetic acid (2,5 – 100) μg/l dichloroacetic acid (2,5 − 100) μg/l trichloroacetic acid (2,5 – 100) μg/l monobromoacetic acid (2,5 – 100) μg/l dibromoacetic acid (2,5 – 100) μg/l Sum of haloacetic acids (HAA) (calculated)
Liquid chromatography with tandem mass spectrometry (LC-MS-MS) PB-W-40 wydanie 1 z dnia 01.10.2023 r.
17 Water Concentration of polycyclic aromatic hydrocarbons (PAH)
benzo(b)fluoranthene (0,004 - 0,10) μg/l benzo(k)fluoranthene (0,003 - 0,10) μg/l benzo(a)pyrene (0,003 - 0,10) μg/l benzo(ghi)perylene (0,004 - 0,10) μg/l indeno(123-cd)pyrene (0,003 - 0,10) μg/l Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) PN-EN ISO 17993:2005
18 Water, Swimming pool water Free chlorine concentration (+)
Range (0,05 – 1,7) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
19 Water, Swimming pool water Total chlorine concentration (+)
Range (0,05 – 1,7) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
20 Water, Swimming pool water Combined chlorine (chloramine) concentration (+) (calculated) PN-EN ISO 7393-2:2018-04
21 Swimming pool water pH
Range 3,0 - 12,0
Potentiometric method PN-EN ISO 10523:2012
22 Swimming pool water Turbidity
Range (0,10 - 1000) NTU
Nephelometric method PN-EN ISO 7027-1:2016-04
23 Swimming pool water Permanganate index
Range (0,7 - 10,0) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
24 Swimming pool water Nitrate concentration
Range (2,0 - 50) mg/l
Ion chromatography with conductometric detection (IC-CD) PN EN ISO 10304-1:2009 +AC:2012
25 Swimming pool water Concentration of volatile organic compounds
chloroform (trichloromethane) (2,0 - 40) μg/l bromodichloromethane (2,0 - 40) μg/l dibromochloromethane (2,0 - 40) μg/l bromoform (2,0 - 40) μg/l Sum of THM (calculated)
Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) PN-EN ISO 10301:2002
26 Water, Water intended for human consumption Anion concentrations
chlorates (0,010 - 1,0) mg/l chlorites (0,010 - 1,0) mg/l Sum of chlorates and chlorites (calculated)
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-4:2022
27 Water, Water intended for human consumption Element concentration
arsenic (0,0010 - 0,10) mg/l antimony (0,0010 - 0,10) mg/l boron 0,050 - 2,0) mg/l chromium (0,0010 - 0,10) mg/l zinc (0,010 - 0,50) mg/l aluminium (0,010 - 0,50) mg/l cadmium (0,0010 - 0,10)mg/l copper (0,010 - 2,0) mg/l manganese (0,0050 - 0,50) mg/l nickel (0,0010 - 0,10) mg/l lead (0,0010 - 0,10) mg/l selenium (0,0010 - 0,10) mg/l silver (0,0010 - 0,10) mg/l iron (0,010 – 2,0) mg/l
Inductively coupled plasma mass spectrometry (ICP-MS) PN-EN ISO 17294-2: 2024-04
28 Water, Wastewater Concentration of volatile organic compounds
chloroform (trichloromethane) (2,0 - 40) μg/l bromodichloromethane (2,0 - 40) μg/l dibromochloromethane (2,0 - 40) μg/l bromoform (2,0 - 40) μg/l Sum of THM (calculated) trichloroethene (2,0 - 40) μg/l tetrachloroethene (2,0 - 40) μg/l hexachloro-1,3-butadiene (0,5 - 5,0) μg/l Range 1,2-dichloroetan (0,5 - 5,0) μg/l Sum of trichloroethene and tetrachloroethene (calculated)
Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) PN-EN ISO 10301:2002
29 Water, Wastewater Concentration of volatile organic compounds
Range 1,2,3-trichlorobenzen (2,0 - 20) μg/l 1,2,4-trichlorobenzene (2,0 - 20) μg/l 1,3,5-trichlorobenzene (2,0 - 20) μg/l benzene (0,5 - 5,0) μg/l Sum of trichlorobenzenes (calculated)
Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) PN-ISO 11423-1:2002
30 Water, Wastewater Concentration of selected organochlorine insecticides
Alpha-HCH (0,02 - 0,2) ug/l Beta-HCH (0,02 - 0,2) μg/l Gamma-HCH (0,02 - 0,2) ug/l Aldrin (0,02 - 0,2) μg/l Dieldrin (0,02 - 0,2) μg/l Endrin (0,02 - 0,2) μg/l Isodrin (0,02 - 0,2) ug/l Heptachlor epoxide (0,02 - 0,2) μg/l Hexachlorobenzene (0,02 - 0,2) μg/l Heptachlor (0,02 - 0,2) μg/l Methoxychlor (DMDT) (0,02 - 0,2) ug/l p,p’-DDT (0,02 - 0,2) μg/l p,p’-DDE (0,02 - 0,2) μg/l p,p’-DDD (0,02 - 0,2) μg/l
Gas chromatography with electron capture detection (GC-ECD) PN-EN ISO 6468:2002
31 Water, Wastewater Total organic carbon concentration (TOC)
Range (0,5 - 100) mg/l
Infrared spectrometry IR PN-EN 1484:1999
32 Water Mercury concentration
Range (0,3 - 5,0) μg/l
Atomic absorption spectrometry with amalgamation technique PB-W-38 wydanie 4 z dnia 08.10.2025 r.
33 Wastewater Mercury concentration
Range (0,4 - 5,0) μg/l
Atomic absorption spectrometry with amalgamation technique PB-W-38 wydanie 4 z dnia 08.10.2025 r.
34 Water, water intended for human consumption Concentration:
4-Nonylphenol (0,1 - 10) μg/l Bisphenol A (0,1 - 10) μg/l 17β-Estradiol (0,1 - 10) μg/l
Liquid chromatography with tandem mass spectrometry (LC-MS-MS) PB-W-41 wydanie 1 z dnia 01.10.2023 r. z wyłączeniem pkt. 3.4.1
35 Water, water intended for human consumption Concentration:
4-Nonylphenol (0,4 – 40) ng/l Bisphenol A (0,4 – 40) ng/l 17β-Estradiol (0,4 – 40) ng/l
Liquid chromatography with tandem mass spectrometry (SPE-LC-MS-MS) PB-W-41 wydanie 1 z dnia 01.10.2023 r.
36 Water Sampling for microbiological testing PN-EN ISO 19458:2007
37 Water Count of bacteria of the genus Legionella, Matrix A, Procedure 5 (BCYE medium), Procedure 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
38 Water Count of bacteria of the genus Legionella, Matrix B, Procedure 7 (medium GVPC) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
39 Water Count of bacteria of the genus Legionella, Matrix A, Procedure 1 (BCYE and BCYE+AB medium) Plate method (spread plate) PN-EN ISO 11731:2017-08 +Ap1:2019-12
40 Water Count of bacteria of the genus Legionella, Matrix B, Procedure 1,2,3 (GVPC medium) Plate method (spread plate) PN-EN ISO 11731:2017-08 +Ap1:2019-12
41 Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
42 Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
43 Water Total count of microorganisms on nutrient agar at 22 °C Plate method, pour plate PN-EN ISO 6222:2004
44 Water Total count of microorganisms on nutrient agar at 36 °C Plate method, pour plate PN-EN ISO 6222:2004
45 Water Faecal streptococci count Membrane filtration method PN-EN ISO 7899-2:2004
46 Water Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10
47 Water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
48 Water Most probable number of coliform bacteria MPN method PN-EN ISO 9308-02:2014
49 Water Most probable number, Escherichia coli MPN method PN-EN ISO 9308-02:2014
50 Water Most probable number of faecal coliform bacteria MPN method PB-B-08 wydanie 3 z dnia 10.08.2021 r. | na podstawie instrukcji obsługi testu Colilert
51 Water Somatic coliphage count Plate method (pour plate) PN-EN ISO 10705-2:2005
52 Water intended for human consumption Coagulase-positive Staphylococci count Membrane filtration method PN-Z -11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1
53 Swimming pool water Total count of microorganisms on nutrient agar at 36 °C Plate method, pour plate PN-EN ISO 6222:2004
54 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
55 Swimming pool water Count of bacteria of the genus Legionella, Matrix A, Procedure 5 (BCYE medium), 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
56 Swimming pool water Count of bacteria of the genus Legionella, Matrix B, Procedure 7 (medium GVPC) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
57 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
58 Swimming pool water Coagulase-positive Staphylococci count Membrane filtration method PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1
59 Waste, code: 19 08 05, 19 09 02 Presence of bacteria of the genus, Salmonella Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 +A1:2020-09
60 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (0,5 – 50,0) °C
Manual and automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
61 Rainwater Sampling for chemical and physical testing
Temperature of the collected sample Range (0,5 – 50,0)°C
Manual method PN-ISO 5667-10: 2021-11 | PN-77/C-04584
62 Water, Wastewater, rainwater Total nitrogen concentration
Range (1,0 – 2000) mg/l
High-temperature combustion with chemiluminescence detection PN-EN ISO 20236:2025-04
63 Water, Wastewater, rainwater Chemical oxygen demand
COD - Cr Range (10,0 - 15000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
64 Water, Wastewater, rainwater Total phosphorus concentration
Range (0,010 - 80,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010
65 Water, Wastewater, rainwater Total suspended solids (TSS)
Range (2,0 - 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
66 Water, Wastewater, rainwater Chloride concentration
Range (4,0 - 3500) mg/l
Titrimetric method PN-ISO 9297:1994
67 Water, Wastewater Ammonium nitrogen concentration
Range (1,2 - 560) mg/l
Titrimetric method PN-ISO 5664:2002
68 Water, Wastewater Nitrate nitrogen concentration
Range (0,04 - 25) mg/l
Spectrophotometric method PN-82/C-04576/08
69 Water, Wastewater Orthophosphate concentration
Range (0,010 - 80,0) mg/l P-PO4
Spectrophotometric method PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010
70 Water, Wastewater pH
Range 3,0 - 12,0
Potentiometric method PN-EN ISO 10523:2012
71 Water, Wastewater Ammonium nitrogen concentration
Range (0,100 - 20,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
72 Water, Wastewater Kjeldahl nitrogen concentration
Range (0,24 - 20,0) mg/l
Spectrometric method PN-EN 25663:2001
73 Water, Wastewater Kjeldahl nitrogen concentration
Range (3,0 - 280) mg/l
Titrimetric method PN-EN 25663:2001
74 Water, Wastewater Total nitrogen concentration (calculated) PN-73C-04576/14
75 Water, Wastewater Biochemical oxygen demand BOD5
Range (6,0 - 4000) mg /l O2
Manometric method PB-S-04 wydanie 2 z dnia 04.01.2021 r.
76 Water, Wastewater Biochemical oxygen demand
BOD5 Range (0,5 - 6,0) mg /l O2
Electrochemical method PN-EN 1899-2:2002
77 Water, Wastewater Phenol index
Range (0,005 - 24,0) mg/l
Spectrophotometric method PB-S-10 wydanie 2 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8047
78 Water, Wastewater Nitrite nitrogen concentration
Range (0,010 - 5,0) mg/l
Spectrophotometric method PN-EN 26777:1999
79 Water, Wastewater Sulfate concentration
Range (10 - 5 000) mg/l
Gravimetric method PN-ISO 9280: 2002
80 Water, Wastewater, Rainwater Mineral oil index
Range (0,20 – 50) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
81 Water, water intended for human consumption, Wastewater, rainwater Total organic carbon concentration (TOC)
Range (0,5 – 6000) mg/l
Infrared spectrometry IR PN-EN 1484:1999
82 Wastewater Concentration of substances extractable with petroleum ether
Range (2,0 - 500) mg/l
Gravimetric method PN-86C-04573/01
83 Wastewater Free cyanide concentration
Range (0,010 - 1,0) mg/l
Spectrophotometric method PB-S-16 wydanie 4 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8027
84 Wastewater Concentration of surfactants
anionic (anionic surfactants) Range (0,05 – 40) mg/l
Spectrophotometric method PB-S-39 wydanie 1 z dnia 02.08.2021 r. wg HACH LCK 332
85 Wastewater Biochemical oxygen demand - BOD5
Range (3 - 3000) mg/l
Electrochemical method PN-EN ISO 5815-1:2019-12
86 Wastewater Chromium(VI) concentration
Range (0,01 - 1,0) mg/l
Spectrophotometric method PN-77/C-04604/08
87 Wastewater Element concentration
chromium (0,050 – 2,0) mg/l zinc (0,080 - 20,0) mg/l aluminium (0,200 – 20,0) mg/l cadmium (0,050 - 2,0) mg/l copper (0,050 – 5,0) mg/l nickel (0,200 - 5,0) mg/l lead (0,200 - 5,0) mg/l iron (0,200 – 50,0) mg/l arsenic (0,050 – 2,0) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
88 Wastewater Sampling for chemical and physical testing
Temperature of the collected wastewater sample Range (0,5 - 50) °C
Manual and automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
89 Water, Wastewater Chemical oxygen demand
COD – Cr Range (10,0 - 15 000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
90 Water, Wastewater Biochemical oxygen demand
BOD5 Range (3 - 2000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
91 Water, Wastewater Biochemical oxygen demand
BOD5 Range (0,5 - 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
92 Water, Wastewater Ammonium nitrogen concentration
Range (1,0 - 250) mg/l
Titrimetric method PN-ISO 5664:2002
93 Water, Wastewater Ammonium nitrogen concentration
Range (0,10 - 40) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
94 Water, Wastewater Nitrate nitrogen concentration
Range (0,10 - 50) mg/l
Spectrophotometric method PN-82/C-04576/08
95 Water, Wastewater Total phosphorus concentration
Range (0,080 - 40) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010
96 Water, Wastewater Orthophosphate concentration
Range (0,080 - 40) mg/l P-PO4
Spectrophotometric method PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010
97 Water, Wastewater Total suspended solids (TSS)
Range (2,0 - 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
98 Water, Wastewater pH
Range (3,0 - 12,0)
Potentiometric method PN-EN ISO 10523:2012
99 Water, Wastewater Kjeldahl nitrogen concentration
Range (0,284 - 25) mg/l
Spectrometric method PN-EN 25663:2001
100 Water, Wastewater Kjeldahl nitrogen concentration
Range (6,5 - 450) mg/l
Titrimetric method PN-EN 25663:2001
101 Water, Wastewater Total nitrogen concentration (calculated) PN-73C-04576/14
102 Water, Wastewater Chloride concentration
Range (6,4 - 3500) mg/l
Titrimetric method PN-ISO 9297:1994
103 Water, Wastewater Phenol index
Range (0,005 - 22,0) mg/l
Spectrophotometric method PB-S-10 wydanie 2 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8047
104 Water, Wastewater Nitrite nitrogen concentration
Range (0,025 - 5,0) mg/l
Spectrophotometric method PN-EN 26777:1999
105 Water, Wastewater Sulfate concentration
Range (10 - 5 000) mg/l
Gravimetric method PN-ISO 9280:2002
106 Water, Wastewater Concentration of anionic surfactants (anionic surfactants)
Range (0,10 – 20) mg/l
Spectrophotometric method PB-S-49 wydanie 2 z dnia 02.09.2022 r. wg HACH LCK 332
107 Water, Wastewater Free cyanide concentration
Range (0,010 – 2,5) mg/l
Spectrophotometric method PB-S-52 wydanie 1 z dnia 01.06.2024 r. wg HACH LCK 315
108 Sewage sludge, Waste, code: 19 08 05 Dry residue and water content
Range (0,5 - 100) %
Gravimetric method PN-EN 12880:2004
109 Sewage sludge, Waste, code: 19 08 05 Loss on ignition and residue on ignition
Range (0,5 - 100) %
Gravimetric method PN-EN 12879:2004
110 Sewage sludge, Waste, code: 19 08 05 pH
Range (3,0 - 13,0)
Potentiometric method PN-EN 12176:2004
111 Sewage sludge, Waste, code: 19 08 05 Kjeldahl nitrogen content
Range (0,14 - 10) %
Titrimetric method PB-S-41 wydanie 2 z dnia 04.01.2021 r.
112 Sewage sludge, Waste, code: 19 08 05 Total phosphorus content
Range (0,05 - 10) %
Spectrophotometric method PB-S-47 wydanie 2 z dnia 04.01.2021 r.
113 Sewage sludge, Waste, code: 19 08 05 Sampling for chemical, biological and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.2, 6.3.3, 6.3.4, 6.3.5, 6.3.6, 6.3.7, 6.3.9, 6.3.10

Reference standards (78)

IO-W-01 wydanie 1 z dnia 10.10.2024 r.
PB-B-08 wydanie 3 z dnia 10.08.2021 r.
PB-S-04 wydanie 2 z dnia 04.01.2021 r.
PB-S-10 wydanie 2 z dnia 04.01.2021 r.
PB-S-16 wydanie 4 z dnia 04.01.2021 r.
PB-S-39 wydanie 1 z dnia 02.08.2021 r. wg HACH LCK 332
PB-S-41 wydanie 2 z dnia 04.01.2021 r.
PB-S-47 wydanie 2 z dnia 04.01.2021 r.
PB-S-49 wydanie 2 z dnia 02.09.2022 r. wg HACH LCK 332
PB-S-52 wydanie 1 z dnia 01.06.2024 r. na podstawie testu kuwetowego HACH LCK 315
PB-S-52 wydanie 1 z dnia 01.06.2024 r. wg HACH LCK 315
PB-W-38 wydanie 4 z dnia 08.10.2025 r.
PB-W-39 wydanie 2 z dnia 04.10.2024 r.
PB-W-40 wydanie 1 z dnia 01. 10.2023 r.
PB-W-40 wydanie 1 z dnia 01.10.2023 r.
PB-W-41 wydanie 1 z dnia 01.10.2023 r.
PB-W-41 wydanie 1 z dnia 01.10.2023 r. z wyłączeniem pkt. 3.4.1
PN -77/C-04584
PN EN ISO 10304-1:2009 +AC:2012
PN-73C-04576/14
PN-77/C-04584
PN-77/C-04604/08
PN-82/C-04576/08
PN-86C-04573/01
PN-EN 12176:2004
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 1484:1999
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10301:2002
PN-EN ISO 10304-4:2022
PN-EN ISO 10523:2012
PN-EN ISO 10705-2:2005
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 11885:2009
PN-EN ISO 14189:2016-10
PN-EN ISO 14911:2002
PN-EN ISO 16266:2009
PN-EN ISO 17294-2: 2024-04
PN-EN ISO 17993:2005
PN-EN ISO 19458:2007
PN-EN ISO 20236:2025-04
PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.2, 6.3.3, 6.3.4, 6.3.5, 6.3.6, 6.3.7, 6.3.9, 6.3.10
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 9.4
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6468:2002
PN-EN ISO 6579-1:2017-04 +A1:2020-09
PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-04
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-02:2014
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9377-2:2003
PN-ISO 11423-1:2002
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10: 2021-11
PN-ISO 5667-10:2021-11
PN-ISO 5667-5: 2017-10
PN-ISO 6059:1999
PN-ISO 7150-1:2002
PN-ISO 9280: 2002
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-Z -11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1
PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1
na podstawie instrukcji obsługi testu Colilert
na podstawie testu kuwetowego HACH nr 8027
na podstawie testu kuwetowego HACH nr 8047