{"lab":{"_id":"69ad52a3de79e566650fb3ea","accr_number":"AB 776","country":"PL","accr_body":"PCA","address":"ul. Senatorska 1, 30-106 Kraków, CENTRALNE LABORATORIUM, ul. Lindego 9, 30-148 Kraków","categories":["water","microbiology","environment"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":113,"name":"WODOCIĄGI MIASTA KRAKOWA S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_776.pdf"],"scope_summary":"","search_text":"wodociągi miasta krakowa s.a. ul. senatorska 1, 30-106 kraków, centralne laboratorium, ul. lindego 9, 30-148 kraków water other pharma electronics materials microbiology environment metrology food","status":"active","updated_at":"2026-03-08T14:51:39.967Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:39.967Z","location":{"type":"Point","coordinates":[19.945,50.0647]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20776,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek osadów, ścieków, wody i wody do spożycia przez ludzi","en":"Chemical tests and sampling of sediments, sewage, water and drinking water"},{"codes":"K/28/P; K/29/P; K/32/P","pl":"Badania mikrobiologiczne i pobieranie próbek osadów, wody i wody do spożycia przez ludzi","en":"Microbiological tests and sampling of sediments, water and drinking water"},{"codes":"N/28/P; N/29/P; N/30/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek osadów, ścieków, wody i wody do spożycia przez ludzi","en":"Tests of physical properties and sampling of sediments, sewage, water and drinking water"}],"issue":{"no":"21","date":"22.01.2026"},"parse_date":"2026-07-20T07:09:50.293Z","parse_source":"script-pdfplumber","map_coord":[50.05565,19.921481],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":112,"microbiology":14,"environment":7,"materials":2,"metrology":1,"petro":1},"category_scores":{"water":91.56,"microbiology":1.43,"environment":0.36,"materials":0.03,"metrology":0.01,"petro":0.01},"has_zh":true},"methods":[{"_id":"6a5dc9bef1c10c8ce825e944","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","methodology_en":"Sampling for chemical and physical testing Temperature","parameters":[{"name":"Zakres","range":"(0,5 – 50,0) °C"}],"parameters_en":[{"name":"Range","range":"(0,5 – 50,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,5 – 50,0) °C","reference":"PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 9.4 | PN -77/C-04584","norm_bases":["PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 9.4","PN -77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,5 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 9.4 | PN -77/C-04584 Woda Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0,5 – 50,0) °C PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt. 7.5, 7.6, 9.4 | PN -77/C-04584","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for chemical and physical testing Temperature Range PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 9.4 | PN -77/C-04584","parameters_zh":[{"name":"范围","range":"(0,5 – 50,0) °C"}],"search_zh":"水 化学和物理检测采样 温度 范围 PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt. 7.5, 7.6, 9.4 | PN -77/C-04584","test_object_zh":"水","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a5dc9bef1c10c8ce825e945","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","methodology_en":"Sampling for chemical and physical testing Temperature","parameters":[{"name":"Zakres","range":"(0,5 – 80,0)°C"}],"parameters_en":[{"name":"Range","range":"(0,5 – 80,0)°C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,5 – 80,0)°C","reference":"PN-ISO 5667-5: 2017-10 | PN -77/C-04584","norm_bases":["PN-ISO 5667-5: 2017-10","PN -77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,5 – 80,0)°C PN-ISO 5667-5: 2017-10 | PN -77/C-04584 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0,5 – 80,0)°C PN-ISO 5667-5: 2017-10 | PN -77/C-04584","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing Temperature Range PN-ISO 5667-5: 2017-10 | PN -77/C-04584","parameters_zh":[{"name":"范围","range":"(0,5 – 80,0)°C"}],"search_zh":"生活饮用水 化学和物理检测采样 温度 范围 PN-ISO 5667-5: 2017-10 | PN -77/C-04584","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a5dc9bef1c10c8ce825e946","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura","methodology_en":"Sampling for chemical and physical testing Temperature","parameters":[{"name":"Zakres","range":"(0,5 – 50,0) °C"}],"parameters_en":[{"name":"Range","range":"(0,5 – 50,0) °C"}],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,5 – 50,0) °C","reference":"IO-W-01 wydanie 1 z dnia 10.10.2024 r. | PN -77/C-04584","norm_bases":["IO-W-01 wydanie 1 z dnia 10.10.2024 r.","PN -77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych Temperatura\nZakres (0,5 – 50,0) °C IO-W-01 wydanie 1 z dnia 10.10.2024 r. | PN -77/C-04584 Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych Temperatura\nZakres (0,5 – 50,0) °C IO-W-01 wydanie 1 z dnia 10.10.2024 r. | PN -77/C-04584","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Sampling for chemical and physical testing Temperature Range IO-W-01 wydanie 1 z dnia 10.10.2024 r. | PN -77/C-04584","parameters_zh":[{"name":"范围","range":"(0,5 – 50,0) °C"}],"search_zh":"游泳池水 化学和物理检测采样 温度 范围 IO-W-01 wydanie 1 z dnia 10.10.2024 r. | PN -77/C-04584","test_object_zh":"游泳池水","methodology_zh":"化学和物理检测采样 温度"},{"_id":"6a5dc9bef1c10c8ce825e947","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"3,0 - 12,0"}],"parameters_en":[{"name":"Range","range":"3,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 3,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda pH\nZakres 3,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda pH\nZakres 3,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 - 12,0"}],"search_zh":"水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e948","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(5,0 - 5000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(5,0 - 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (5,0 - 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (5,0 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (5,0 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5,0 - 5000) μS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e949","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 - 1000) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 - 1000) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 - 1000) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-04","norm_bases":["PN-EN ISO 7027-1:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Mętność\nZakres (0,10 - 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-04 Woda Metnosc\nZakres (0,10 - 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-04","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-04","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 - 1000) NTU"}],"search_zh":"水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-04","technique_zh":"浊度法（散射法）","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e94a","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(11,0 - 800) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(11,0 - 800) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (11,0 - 800) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (11,0 - 800) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (11,0 - 800) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(11,0 - 800) mg/l CaCO3"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e94b","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,7 - 10,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,7 - 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,7 - 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Indeks nadmanganianowy\nZakres (0,7 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy\nZakres (0,7 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,7 - 10,0) mg/l"}],"search_zh":"水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e94c","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 - 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 - 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 - 1000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Zawiesiny ogólne\nZakres (2,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda Zawiesiny ogolne\nZakres (2,0 - 1000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 - 1000) mg/l"}],"search_zh":"水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e94d","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"fluorki","range":"(0,014 - 1,00) mg/l"},{"name":"chlorki","range":"(2,5 - 250) mg/l"},{"name":"azotyny","range":"(0,010 - 0,5) mg/l"},{"name":"azotany","range":"(2,0 - 100) mg/l"},{"name":"fosforany","range":"(0,020 - 1,0) mg/l)"},{"name":"siarczany","range":"(5,0 - 250) mg/l"}],"parameters_en":[{"name":"fluorides","range":"(0,014 - 1,00) mg/l"},{"name":"chlorides","range":"(2,5 - 250) mg/l"},{"name":"nitrites","range":"(0,010 - 0,5) mg/l"},{"name":"nitrates","range":"(2,0 - 100) mg/l"},{"name":"phosphates","range":"(0,020 - 1,0) mg/l)"},{"name":"sulfates","range":"(5,0 - 250) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nfluorki (0,014 - 1,00) mg/l\nchlorki (2,5 - 250) mg/l\nazotyny (0,010 - 0,5) mg/l\nazotany (2,0 - 100) mg/l\nfosforany (0,020 - 1,0) mg/l)\nsiarczany (5,0 - 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN EN ISO 10304-1:2009 +AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie anionów\nZakres:\nfluorki (0,014 - 1,00) mg/l\nchlorki (2,5 - 250) mg/l\nazotyny (0,010 - 0,5) mg/l\nazotany (2,0 - 100) mg/l\nfosforany (0,020 - 1,0) mg/l)\nsiarczany (5,0 - 250) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN EN ISO 10304-1:2009 +AC:2012 Woda Stezenie anionow\nZakres:\nfluorki (0,014 - 1,00) mg/l\nchlorki (2,5 - 250) mg/l\nazotyny (0,010 - 0,5) mg/l\nazotany (2,0 - 100) mg/l\nfosforany (0,020 - 1,0) mg/l)\nsiarczany (5,0 - 250) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Anion concentrations Ion chromatography with conductometric detection (IC-CD) fluorides chlorides nitrites nitrates phosphates sulfates PN EN ISO 10304-1:2009 +AC:2012","methodology_zh":"阴离子浓度","search_zh":"水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氟化物 氯化物 亚硝酸盐 硝酸盐 磷酸盐 硫酸盐 PN EN ISO 10304-1:2009 +AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"氟化物","range":"(0,014 - 1,00) mg/l"},{"name":"氯化物","range":"(2,5 - 250) mg/l"},{"name":"亚硝酸盐","range":"(0,010 - 0,5) mg/l"},{"name":"硝酸盐","range":"(2,0 - 100) mg/l"},{"name":"磷酸盐","range":"(0,020 - 1,0) mg/l)"},{"name":"硫酸盐","range":"(5,0 - 250) mg/l"}]},{"_id":"6a5dc9bef1c10c8ce825e94e","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(1 - 40) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(1 - 40) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (1 - 40) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa\nZakres (1 - 40) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7 Woda Barwa\nZakres (1 - 40) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Colour Visual method Range PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(1 - 40) mg/l Pt"}],"search_zh":"水 色度 目视法 范围 PN-EN ISO 7887:2012 +Ap1:2015, pkt. 7","technique_zh":"目视法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e94f","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie kationów","methodology_en":"Cation concentrations","parameters":[{"name":"sód","range":"(4,0 - 100) mg/l"},{"name":"jon amonowy","range":"(0,02 - 1) mg/l"},{"name":"magnez","range":"(2,0 - 50) mg/l"},{"name":"wapń","range":"(5,0 - 120) mg/l"}],"parameters_en":[{"name":"sodium","range":"(4,0 - 100) mg/l"},{"name":"ammonium ion","range":"(0,02 - 1) mg/l"},{"name":"magnesium","range":"(2,0 - 50) mg/l"},{"name":"calcium","range":"(5,0 - 120) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie kationów\nZakres:\nsód (4,0 - 100) mg/l\njon amonowy (0,02 - 1) mg/l\nmagnez (2,0 - 50) mg/l\nwapń (5,0 - 120) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 14911:2002","norm_bases":["PN-EN ISO 14911:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie kationów\nZakres:\nsód (4,0 - 100) mg/l\njon amonowy (0,02 - 1) mg/l\nmagnez (2,0 - 50) mg/l\nwapń (5,0 - 120) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 14911:2002 Woda Stezenie kationow\nZakres:\nsod (4,0 - 100) mg/l\njon amonowy (0,02 - 1) mg/l\nmagnez (2,0 - 50) mg/l\nwapn (5,0 - 120) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 14911:2002","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Cation concentrations Ion chromatography with conductometric detection (IC-CD) sodium ammonium ion magnesium calcium PN-EN ISO 14911:2002","search_zh":"水 阳离子浓度 离子色谱-电导检测法（IC-CD） 钠 镁 钙 PN-EN ISO 14911:2002","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水","parameters_zh":[{"name":"钠","range":"(4,0 - 100) mg/l"},{"name":"jon amonowy","range":"(0,02 - 1) mg/l"},{"name":"镁","range":"(2,0 - 50) mg/l"},{"name":"钙","range":"(5,0 - 120) mg/l"}],"methodology_zh":"阳离子浓度"},{"_id":"6a5dc9bef1c10c8ce825e950","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie kwasów poli- i perfluoroalkilowych (PFAS)","methodology_en":"Poly- and perfluoroalkyl acids (PFAS) concentration","parameters":[{"name":"kwas perfluorobutanowy (PFBA)"},{"name":"Zakres","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluoropentanowy (PFPA)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluoroheksanowy (PFHxA)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluoroheptanowy (PFHpA)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorooktanowy (PFOA)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorononanowy (PFNA)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorodekanowy (PFDA)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluoroundekanowy (PFUnDA)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorododekanowy (PFDoDA)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorotridekanowy (PFTrDA)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorobutanosulfonowy (PF BS)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluoropentanosulfonowy (PFPS)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluoroheksanosulfonowy (PFHxS)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluoroheptanosulfonowy (PFHpS)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorooktanosulfonowy (PFOS)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorononanosulfonowy (PFNS)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorodekanosulfonowy (PFDS)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluoroundekanosulfonowy","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorododekanosulfonowy","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorotridekanosulfonowy","range":"(0,0012-0,20) μg/l"},{"name":"Suma PFAS (z obliczeń)"}],"parameters_en":[{"name":"perfluorobutanoic acid (PFBA)"},{"name":"Range","range":"(0,0012-0,20) μg/l"},{"name":"perfluoropentanoic acid (PFPA)","range":"(0,0012-0,20) μg/l"},{"name":"perfluorohexanoic acid (PFHxA)","range":"(0,0012-0,20) μg/l"},{"name":"perfluoroheptanoic acid (PFHpA)","range":"(0,0012-0,20) μg/l"},{"name":"perfluorooctanoic acid (PFOA)","range":"(0,0012-0,20) μg/l"},{"name":"perfluorononanoic acid (PFNA)","range":"(0,0012-0,20) μg/l"},{"name":"perfluorodecanoic acid (PFDA)","range":"(0,0012-0,20) μg/l"},{"name":"perfluoroundecanoic acid (PFUnDA)","range":"(0,0012-0,20) μg/l"},{"name":"perfluorododecanoic acid (PFDoDA)","range":"(0,0012-0,20) μg/l"},{"name":"perfluorotridecanoic acid (PFTrDA)","range":"(0,0012-0,20) μg/l"},{"name":"perfluorobutanesulfonic acid (PF BS)","range":"(0,0012-0,20) μg/l"},{"name":"perfluoropentanesulfonic acid (PFPS)","range":"(0,0012-0,20) μg/l"},{"name":"perfluorohexanesulfonic acid (PFHxS)","range":"(0,0012-0,20) μg/l"},{"name":"perfluoroheptanesulfonic acid (PFHpS)","range":"(0,0012-0,20) μg/l"},{"name":"perfluorooctanesulfonic acid (PFOS)","range":"(0,0012-0,20) μg/l"},{"name":"perfluorononanesulfonic acid (PFNS)","range":"(0,0012-0,20) μg/l"},{"name":"perfluorodecanesulfonic acid (PFDS)","range":"(0,0012-0,20) μg/l"},{"name":"perfluoroundecanesulfonic acid","range":"(0,0012-0,20) μg/l"},{"name":"perfluorododecanesulfonic acid","range":"(0,0012-0,20) μg/l"},{"name":"perfluorotridecanesulfonic acid","range":"(0,0012-0,20) μg/l"},{"name":"Sum of PFAS (calculated)"}],"technique":"Metoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS)"],"technique_en":"Liquid chromatography with tandem mass spectrometry (LC-MS-MS)","computed":[],"computed_en":[],"activity":"Stężenie kwasów poli- i perfluoroalkilowych (PFAS)\nZakres:\nkwas perfluorobutanowy (PFBA)\nZakres (0,0012-0,20) μg/l\nkwas perfluoropentanowy (PFPA) (0,0012-0,20) μg/l\nkwas perfluoroheksanowy (PFHxA) (0,0012-0,20) μg/l\nkwas perfluoroheptanowy (PFHpA) (0,0012-0,20) μg/l\nkwas perfluorooktanowy (PFOA) (0,0012-0,20) μg/l\nkwas perfluorononanowy (PFNA) (0,0012-0,20) μg/l\nkwas perfluorodekanowy (PFDA) (0,0012-0,20) μg/l\nkwas perfluoroundekanowy (PFUnDA) (0,0012-0,20) μg/l\nkwas perfluorododekanowy (PFDoDA) (0,0012-0,20) μg/l\nkwas perfluorotridekanowy (PFTrDA) (0,0012-0,20) μg/l\nkwas perfluorobutanosulfonowy (PF BS) (0,0012-0,20) μg/l\nkwas perfluoropentanosulfonowy (PFPS) (0,0012-0,20) μg/l\nkwas perfluoroheksanosulfonowy (PFHxS) (0,0012-0,20) μg/l\nkwas perfluoroheptanosulfonowy (PFHpS) (0,0012-0,20) μg/l\nkwas perfluorooktanosulfonowy (PFOS) (0,0012-0,20) μg/l\nkwas perfluorononanosulfonowy (PFNS) (0,0012-0,20) μg/l\nkwas perfluorodekanosulfonowy (PFDS) (0,0012-0,20) μg/l\nkwas perfluoroundekanosulfonowy (0,0012-0,20) μg/l\nkwas perfluorododekanosulfonowy (0,0012-0,20) μg/l\nkwas perfluorotridekanosulfonowy (0,0012-0,20) μg/l\nSuma PFAS (z obliczeń)\nMetoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS)","reference":"PB-W-39 wydanie 2 z dnia 04.10.2024 r.","norm_bases":["PB-W-39 wydanie 2 z dnia 04.10.2024 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie kwasów poli- i perfluoroalkilowych (PFAS)\nZakres:\nkwas perfluorobutanowy (PFBA)\nZakres (0,0012-0,20) μg/l\nkwas perfluoropentanowy (PFPA) (0,0012-0,20) μg/l\nkwas perfluoroheksanowy (PFHxA) (0,0012-0,20) μg/l\nkwas perfluoroheptanowy (PFHpA) (0,0012-0,20) μg/l\nkwas perfluorooktanowy (PFOA) (0,0012-0,20) μg/l\nkwas perfluorononanowy (PFNA) (0,0012-0,20) μg/l\nkwas perfluorodekanowy (PFDA) (0,0012-0,20) μg/l\nkwas perfluoroundekanowy (PFUnDA) (0,0012-0,20) μg/l\nkwas perfluorododekanowy (PFDoDA) (0,0012-0,20) μg/l\nkwas perfluorotridekanowy (PFTrDA) (0,0012-0,20) μg/l\nkwas perfluorobutanosulfonowy (PF BS) (0,0012-0,20) μg/l\nkwas perfluoropentanosulfonowy (PFPS) (0,0012-0,20) μg/l\nkwas perfluoroheksanosulfonowy (PFHxS) (0,0012-0,20) μg/l\nkwas perfluoroheptanosulfonowy (PFHpS) (0,0012-0,20) μg/l\nkwas perfluorooktanosulfonowy (PFOS) (0,0012-0,20) μg/l\nkwas perfluorononanosulfonowy (PFNS) (0,0012-0,20) μg/l\nkwas perfluorodekanosulfonowy (PFDS) (0,0012-0,20) μg/l\nkwas perfluoroundekanosulfonowy (0,0012-0,20) μg/l\nkwas perfluorododekanosulfonowy (0,0012-0,20) μg/l\nkwas perfluorotridekanosulfonowy (0,0012-0,20) μg/l\nSuma PFAS (z obliczeń)\nMetoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS) PB-W-39 wydanie 2 z dnia 04.10.2024 r. Woda Stezenie kwasow poli- i perfluoroalkilowych (PFAS)\nZakres:\nkwas perfluorobutanowy (PFBA)\nZakres (0,0012-0,20) μg/l\nkwas perfluoropentanowy (PFPA) (0,0012-0,20) μg/l\nkwas perfluoroheksanowy (PFHxA) (0,0012-0,20) μg/l\nkwas perfluoroheptanowy (PFHpA) (0,0012-0,20) μg/l\nkwas perfluorooktanowy (PFOA) (0,0012-0,20) μg/l\nkwas perfluorononanowy (PFNA) (0,0012-0,20) μg/l\nkwas perfluorodekanowy (PFDA) (0,0012-0,20) μg/l\nkwas perfluoroundekanowy (PFUnDA) (0,0012-0,20) μg/l\nkwas perfluorododekanowy (PFDoDA) (0,0012-0,20) μg/l\nkwas perfluorotridekanowy (PFTrDA) (0,0012-0,20) μg/l\nkwas perfluorobutanosulfonowy (PF BS) (0,0012-0,20) μg/l\nkwas perfluoropentanosulfonowy (PFPS) (0,0012-0,20) μg/l\nkwas perfluoroheksanosulfonowy (PFHxS) (0,0012-0,20) μg/l\nkwas perfluoroheptanosulfonowy (PFHpS) (0,0012-0,20) μg/l\nkwas perfluorooktanosulfonowy (PFOS) (0,0012-0,20) μg/l\nkwas perfluorononanosulfonowy (PFNS) (0,0012-0,20) μg/l\nkwas perfluorodekanosulfonowy (PFDS) (0,0012-0,20) μg/l\nkwas perfluoroundekanosulfonowy (0,0012-0,20) μg/l\nkwas perfluorododekanosulfonowy (0,0012-0,20) μg/l\nkwas perfluorotridekanosulfonowy (0,0012-0,20) μg/l\nSuma PFAS (z obliczen)\nMetoda chromatografii cieczowej z tandemowa spektrometria mas (LC-MS-MS) PB-W-39 wydanie 2 z dnia 04.10.2024 r.","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Poly- and perfluoroalkyl acids (PFAS) concentration Liquid chromatography with tandem mass spectrometry (LC-MS-MS) perfluorobutanoic acid (PFBA) Range perfluoropentanoic acid (PFPA) perfluorohexanoic acid (PFHxA) perfluoroheptanoic acid (PFHpA) perfluorooctanoic acid (PFOA) perfluorononanoic acid (PFNA) perfluorodecanoic acid (PFDA) perfluoroundecanoic acid (PFUnDA) perfluorododecanoic acid (PFDoDA) perfluorotridecanoic acid (PFTrDA) perfluorobutanesulfonic acid (PF BS) perfluoropentanesulfonic acid (PFPS) perfluorohexanesulfonic acid (PFHxS) perfluoroheptanesulfonic acid (PFHpS) perfluorooctanesulfonic acid (PFOS) perfluorononanesulfonic acid (PFNS) perfluorodecanesulfonic acid (PFDS) perfluoroundecanesulfonic acid perfluorododecanesulfonic acid perfluorotridecanesulfonic acid Sum of PFAS (calculated) PB-W-39 wydanie 2 z dnia 04.10.2024 r.","parameters_zh":[{"name":"全氟丁酸（PFBA）"},{"name":"范围","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluoropentanowy (PFPA)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluoroheksanowy (PFHxA)","range":"(0,0012-0,20) μg/l"},{"name":"全氟庚酸（PFHpA）","range":"(0,0012-0,20) μg/l"},{"name":"全氟辛酸（PFOA）","range":"(0,0012-0,20) μg/l"},{"name":"全氟壬酸（PFNA）","range":"(0,0012-0,20) μg/l"},{"name":"全氟癸酸（PFDA）","range":"(0,0012-0,20) μg/l"},{"name":"全氟十一酸（PFUnDA）","range":"(0,0012-0,20) μg/l"},{"name":"全氟十二酸（PFDoDA）","range":"(0,0012-0,20) μg/l"},{"name":"全氟十三酸（PFTrDA）","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorobutanosulfonowy (PF BS)","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluoropentanosulfonowy (PFPS)","range":"(0,0012-0,20) μg/l"},{"name":"全氟己烷磺酸（PFHxS）","range":"(0,0012-0,20) μg/l"},{"name":"全氟庚烷磺酸（PFHpS）","range":"(0,0012-0,20) μg/l"},{"name":"全氟辛烷磺酸（PFOS）","range":"(0,0012-0,20) μg/l"},{"name":"全氟壬烷磺酸（PFNS）","range":"(0,0012-0,20) μg/l"},{"name":"全氟癸烷磺酸（PFDS）","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluoroundekanosulfonowy","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorododekanosulfonowy","range":"(0,0012-0,20) μg/l"},{"name":"kwas perfluorotridekanosulfonowy","range":"(0,0012-0,20) μg/l"},{"name":"PFAS 总量（由计算得出）"}],"search_zh":"水 液相色谱-串联质谱法（LC-MS-MS） 全氟丁酸（PFBA） 范围 全氟庚酸（PFHpA） 全氟辛酸（PFOA） 全氟壬酸（PFNA） 全氟癸酸（PFDA） 全氟十一酸（PFUnDA） 全氟十二酸（PFDoDA） 全氟十三酸（PFTrDA） 全氟己烷磺酸（PFHxS） 全氟庚烷磺酸（PFHpS） 全氟辛烷磺酸（PFOS） 全氟壬烷磺酸（PFNS） 全氟癸烷磺酸（PFDS） PFAS 总量（由计算得出） PB-W-39 wydanie 2 z dnia 04.10.2024 r.","test_object_zh":"水","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a5dc9bef1c10c8ce825e951","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie cyjanków wolnych","methodology_en":"Free cyanide concentration","parameters":[{"name":"Zakres","range":"(0,010 – 0,070) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 – 0,070) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie cyjanków wolnych\nZakres (0,010 – 0,070) mg/l\nMetoda spektrofotometryczna","reference":"PB-S-52 wydanie 1 z dnia 01.06.2024 r. na podstawie testu kuwetowego HACH LCK 315","norm_bases":["PB-S-52 wydanie 1 z dnia 01.06.2024 r. na podstawie testu kuwetowego HACH LCK 315"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie cyjanków wolnych\nZakres (0,010 – 0,070) mg/l\nMetoda spektrofotometryczna PB-S-52 wydanie 1 z dnia 01.06.2024 r. na podstawie testu kuwetowego HACH LCK 315 Woda Stezenie cyjankow wolnych\nZakres (0,010 – 0,070) mg/l\nMetoda spektrofotometryczna PB-S-52 wydanie 1 z dnia 01.06.2024 r. na podstawie testu kuwetowego HACH LCK 315","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Free cyanide concentration Spectrophotometric method Range PB-S-52 wydanie 1 z dnia 01.06.2024 r. na podstawie testu kuwetowego HACH LCK 315","parameters_zh":[{"name":"范围","range":"(0,010 – 0,070) mg/l"}],"search_zh":"水 游离氰化物浓度 分光光度法 范围 PB-S-52 wydanie 1 z dnia 01.06.2024 r. na podstawie testu kuwetowego HACH LCK 315","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"游离氰化物浓度"},{"_id":"6a5dc9bef1c10c8ce825e952","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie bromianów","methodology_en":"Bromate concentration","parameters":[{"name":"Zakres","range":"(2,5-100) μg/l"}],"parameters_en":[{"name":"Range","range":"(2,5-100) μg/l"}],"technique":"Metoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS)"],"technique_en":"Liquid chromatography with tandem mass spectrometry (LC-MS-MS)","computed":[],"computed_en":[],"activity":"Stężenie bromianów\nZakres (2,5-100) μg/l\nMetoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS)","reference":"PB-W-40 wydanie 1 z dnia 01. 10.2023 r.","norm_bases":["PB-W-40 wydanie 1 z dnia 01. 10.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie bromianów\nZakres (2,5-100) μg/l\nMetoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS) PB-W-40 wydanie 1 z dnia 01. 10.2023 r. Woda Stezenie bromianow\nZakres (2,5-100) μg/l\nMetoda chromatografii cieczowej z tandemowa spektrometria mas (LC-MS-MS) PB-W-40 wydanie 1 z dnia 01. 10.2023 r.","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Bromate concentration Liquid chromatography with tandem mass spectrometry (LC-MS-MS) Range PB-W-40 wydanie 1 z dnia 01. 10.2023 r.","parameters_zh":[{"name":"范围","range":"(2,5-100) μg/l"}],"search_zh":"水 溴酸盐浓度 液相色谱-串联质谱法（LC-MS-MS） 范围 PB-W-40 wydanie 1 z dnia 01. 10.2023 r.","test_object_zh":"水","methodology_zh":"溴酸盐浓度","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a5dc9bef1c10c8ce825e953","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie kwasów halogenooctowych (HAA)","methodology_en":"Haloacetic acid (HAA) concentration","parameters":[{"name":"kwas monochlorooctowy","range":"(2,5 – 100) μg/l"},{"name":"kwas dichlorooctowy","range":"(2,5 − 100) μg/l"},{"name":"kwas trichlorooctowy","range":"(2,5 – 100) μg/l"},{"name":"kwas monobromooctowy","range":"(2,5 – 100) μg/l"},{"name":"kwas dibromooctowy","range":"(2,5 – 100) μg/l"},{"name":"Suma kwasów halogenooctowych (HAA) (z obliczeń)"}],"parameters_en":[{"name":"monochloroacetic acid","range":"(2,5 – 100) μg/l"},{"name":"dichloroacetic acid","range":"(2,5 − 100) μg/l"},{"name":"trichloroacetic acid","range":"(2,5 – 100) μg/l"},{"name":"monobromoacetic acid","range":"(2,5 – 100) μg/l"},{"name":"dibromoacetic acid","range":"(2,5 – 100) μg/l"},{"name":"Sum of haloacetic acids (HAA) (calculated)"}],"technique":"Metoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS)"],"technique_en":"Liquid chromatography with tandem mass spectrometry (LC-MS-MS)","computed":[],"computed_en":[],"activity":"Stężenie kwasów halogenooctowych (HAA)\nZakres:\nkwas monochlorooctowy (2,5 – 100) μg/l\nkwas dichlorooctowy (2,5 − 100) μg/l\nkwas trichlorooctowy (2,5 – 100) μg/l\nkwas monobromooctowy (2,5 – 100) μg/l\nkwas dibromooctowy (2,5 – 100) μg/l\nSuma kwasów halogenooctowych (HAA) (z obliczeń)\nMetoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS)","reference":"PB-W-40 wydanie 1 z dnia 01.10.2023 r.","norm_bases":["PB-W-40 wydanie 1 z dnia 01.10.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie kwasów halogenooctowych (HAA)\nZakres:\nkwas monochlorooctowy (2,5 – 100) μg/l\nkwas dichlorooctowy (2,5 − 100) μg/l\nkwas trichlorooctowy (2,5 – 100) μg/l\nkwas monobromooctowy (2,5 – 100) μg/l\nkwas dibromooctowy (2,5 – 100) μg/l\nSuma kwasów halogenooctowych (HAA) (z obliczeń)\nMetoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS) PB-W-40 wydanie 1 z dnia 01.10.2023 r. Woda Stezenie kwasow halogenooctowych (HAA)\nZakres:\nkwas monochlorooctowy (2,5 – 100) μg/l\nkwas dichlorooctowy (2,5 − 100) μg/l\nkwas trichlorooctowy (2,5 – 100) μg/l\nkwas monobromooctowy (2,5 – 100) μg/l\nkwas dibromooctowy (2,5 – 100) μg/l\nSuma kwasow halogenooctowych (HAA) (z obliczen)\nMetoda chromatografii cieczowej z tandemowa spektrometria mas (LC-MS-MS) PB-W-40 wydanie 1 z dnia 01.10.2023 r.","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Haloacetic acid (HAA) concentration Liquid chromatography with tandem mass spectrometry (LC-MS-MS) monochloroacetic acid dichloroacetic acid trichloroacetic acid monobromoacetic acid dibromoacetic acid Sum of haloacetic acids (HAA) (calculated) PB-W-40 wydanie 1 z dnia 01.10.2023 r.","search_zh":"水 卤乙酸（HAA）浓度 液相色谱-串联质谱法（LC-MS-MS） 一氯乙酸 二氯乙酸 三氯乙酸 一溴乙酸 二溴乙酸 PB-W-40 wydanie 1 z dnia 01.10.2023 r.","test_object_zh":"水","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）","methodology_zh":"卤乙酸（HAA）浓度","parameters_zh":[{"name":"一氯乙酸","range":"(2,5 – 100) μg/l"},{"name":"二氯乙酸","range":"(2,5 − 100) μg/l"},{"name":"三氯乙酸","range":"(2,5 – 100) μg/l"},{"name":"一溴乙酸","range":"(2,5 – 100) μg/l"},{"name":"二溴乙酸","range":"(2,5 – 100) μg/l"},{"name":"Suma kwasów halogenooctowych (HAA) (z obliczeń)"}]},{"_id":"6a5dc9bef1c10c8ce825e954","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters":[{"name":"benzo(b)fluoranten","range":"(0,004 - 0,10) μg/l"},{"name":"benzo(k)fluoranten","range":"(0,003 - 0,10) μg/l"},{"name":"benzo(a)piren","range":"(0,003 - 0,10) μg/l"},{"name":"benzo(ghi)perylen","range":"(0,004 - 0,10) μg/l"},{"name":"indeno(123-cd)piren","range":"(0,003 - 0,10) μg/l"},{"name":"Suma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)"}],"parameters_en":[{"name":"benzo(b)fluoranthene","range":"(0,004 - 0,10) μg/l"},{"name":"benzo(k)fluoranthene","range":"(0,003 - 0,10) μg/l"},{"name":"benzo(a)pyrene","range":"(0,003 - 0,10) μg/l"},{"name":"benzo(ghi)perylene","range":"(0,004 - 0,10) μg/l"},{"name":"indeno(123-cd)pyrene","range":"(0,003 - 0,10) μg/l"},{"name":"Sum of polycyclic aromatic hydrocarbons (PAH) (calculated)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","computed":[],"computed_en":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nbenzo(b)fluoranten (0,004 - 0,10) μg/l\nbenzo(k)fluoranten (0,003 - 0,10) μg/l\nbenzo(a)piren (0,003 - 0,10) μg/l\nbenzo(ghi)perylen (0,004 - 0,10) μg/l\nindeno(123-cd)piren (0,003 - 0,10) μg/l\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PN-EN ISO 17993:2005","norm_bases":["PN-EN ISO 17993:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nbenzo(b)fluoranten (0,004 - 0,10) μg/l\nbenzo(k)fluoranten (0,003 - 0,10) μg/l\nbenzo(a)piren (0,003 - 0,10) μg/l\nbenzo(ghi)perylen (0,004 - 0,10) μg/l\nindeno(123-cd)piren (0,003 - 0,10) μg/l\nSuma wielopierścieniowych węglowodorów aromatycznych (WWA) (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PN-EN ISO 17993:2005 Woda Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nbenzo(b)fluoranten (0,004 - 0,10) μg/l\nbenzo(k)fluoranten (0,003 - 0,10) μg/l\nbenzo(a)piren (0,003 - 0,10) μg/l\nbenzo(ghi)perylen (0,004 - 0,10) μg/l\nindeno(123-cd)piren (0,003 - 0,10) μg/l\nSuma wielopierscieniowych weglowodorow aromatycznych (WWA) (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PN-EN ISO 17993:2005","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD) benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(ghi)perylene indeno(123-cd)pyrene Sum of polycyclic aromatic hydrocarbons (PAH) (calculated) PN-EN ISO 17993:2005","search_zh":"水 多环芳烃（PAHs）浓度 高效液相色谱-荧光检测法（HPLC-FLD） 苯并（b）荧蒽 苯并（k）荧蒽 苯并（a）芘 苯并（ghi）苝 多环芳烃（PAH）总量（由计算得出） PN-EN ISO 17993:2005","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"水","parameters_zh":[{"name":"苯并（b）荧蒽","range":"(0,004 - 0,10) μg/l"},{"name":"苯并（k）荧蒽","range":"(0,003 - 0,10) μg/l"},{"name":"苯并（a）芘","range":"(0,003 - 0,10) μg/l"},{"name":"苯并（ghi）苝","range":"(0,004 - 0,10) μg/l"},{"name":"indeno(123-cd)piren","range":"(0,003 - 0,10) μg/l"},{"name":"多环芳烃（PAH）总量（由计算得出）"}],"methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a5dc9bef1c10c8ce825e955","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Woda na pływalniach","test_object_en":"Water, Swimming pool water","methodology":"Stężenie chloru wolnego (+)","methodology_en":"Free chlorine concentration (+)","parameters":[{"name":"Zakres","range":"(0,05 – 1,7) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 1,7) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego (+)\nZakres (0,05 – 1,7) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda na pływalniach Stężenie chloru wolnego (+)\nZakres (0,05 – 1,7) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda, Woda na plywalniach Stezenie chloru wolnego (+)\nZakres (0,05 – 1,7) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Swimming pool water Free chlorine concentration (+) Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","parameters_zh":[{"name":"范围","range":"(0,05 – 1,7) mg/l"}],"search_zh":"水、游泳池水 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"水、游泳池水"},{"_id":"6a5dc9bef1c10c8ce825e956","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Woda na pływalniach","test_object_en":"Water, Swimming pool water","methodology":"Stężenie chloru całkowitego (+)","methodology_en":"Total chlorine concentration (+)","parameters":[{"name":"Zakres","range":"(0,05 – 1,7) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 1,7) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru całkowitego (+)\nZakres (0,05 – 1,7) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda na pływalniach Stężenie chloru całkowitego (+)\nZakres (0,05 – 1,7) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda, Woda na plywalniach Stezenie chloru calkowitego (+)\nZakres (0,05 – 1,7) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Swimming pool water Total chlorine concentration (+) Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","parameters_zh":[{"name":"范围","range":"(0,05 – 1,7) mg/l"}],"search_zh":"水、游泳池水 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"水、游泳池水"},{"_id":"6a5dc9bef1c10c8ce825e957","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Woda na pływalniach","test_object_en":"Water, Swimming pool water","methodology":"Stężenie chloru związanego (chloramin) (+) (z obliczeń)","methodology_en":"Combined chlorine (chloramine) concentration (+) (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru związanego (chloramin) (+) (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda na pływalniach Stężenie chloru związanego (chloramin) (+) (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda, Woda na plywalniach Stezenie chloru zwiazanego (chloramin) (+) (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Swimming pool water Combined chlorine (chloramine) concentration (+) (calculated) PN-EN ISO 7393-2:2018-04","search_zh":"水、游泳池水 PN-EN ISO 7393-2:2018-04","test_object_zh":"水、游泳池水"},{"_id":"6a5dc9bef1c10c8ce825e958","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"3,0 - 12,0"}],"parameters_en":[{"name":"Range","range":"3,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 3,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach pH\nZakres 3,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda na plywalniach pH\nZakres 3,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 - 12,0"}],"search_zh":"游泳池水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bef1c10c8ce825e959","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 - 1000) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 - 1000) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 - 1000) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-04","norm_bases":["PN-EN ISO 7027-1:2016-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Mętność\nZakres (0,10 - 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-04 Woda na plywalniach Metnosc\nZakres (0,10 - 1000) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-04","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-04","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 - 1000) NTU"}],"search_zh":"游泳池水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-04","technique_zh":"浊度法（散射法）","test_object_zh":"游泳池水"},{"_id":"6a5dc9bef1c10c8ce825e95a","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,7 - 10,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,7 - 10,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,7 - 10,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Indeks nadmanganianowy\nZakres (0,7 - 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda na plywalniach Indeks nadmanganianowy\nZakres (0,7 - 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,7 - 10,0) mg/l O2"}],"search_zh":"游泳池水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bef1c10c8ce825e95b","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(2,0 - 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 - 50) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (2,0 - 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN EN ISO 10304-1:2009 +AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie azotanów\nZakres (2,0 - 50) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN EN ISO 10304-1:2009 +AC:2012 Woda na plywalniach Stezenie azotanow\nZakres (2,0 - 50) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Nitrate concentration Ion chromatography with conductometric detection (IC-CD) Range PN EN ISO 10304-1:2009 +AC:2012","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(2,0 - 50) mg/l"}],"search_zh":"游泳池水 硝酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 PN EN ISO 10304-1:2009 +AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"游泳池水"},{"_id":"6a5dc9bef1c10c8ce825e95c","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie lotnych związków organicznych","methodology_en":"Concentration of volatile organic compounds","parameters":[{"name":"chloroform (trichlorometan)","range":"(2,0 - 40) μg/l"},{"name":"bromodichlorometan","range":"(2,0 - 40) μg/l"},{"name":"dibromochlorometan","range":"(2,0 - 40) μg/l"},{"name":"bromoform","range":"(2,0 - 40) μg/l"},{"name":"Suma THM (z obliczeń)"}],"parameters_en":[{"name":"chloroform (trichloromethane)","range":"(2,0 - 40) μg/l"},{"name":"bromodichloromethane","range":"(2,0 - 40) μg/l"},{"name":"dibromochloromethane","range":"(2,0 - 40) μg/l"},{"name":"bromoform","range":"(2,0 - 40) μg/l"},{"name":"Sum of THM (calculated)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie lotnych związków organicznych\nZakres:\nchloroform (trichlorometan) (2,0 - 40) μg/l\nbromodichlorometan (2,0 - 40) μg/l\ndibromochlorometan (2,0 - 40) μg/l\nbromoform (2,0 - 40) μg/l\nSuma THM (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie lotnych związków organicznych\nZakres:\nchloroform (trichlorometan) (2,0 - 40) μg/l\nbromodichlorometan (2,0 - 40) μg/l\ndibromochlorometan (2,0 - 40) μg/l\nbromoform (2,0 - 40) μg/l\nSuma THM (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 10301:2002 Woda na plywalniach Stezenie lotnych zwiazkow organicznych\nZakres:\nchloroform (trichlorometan) (2,0 - 40) μg/l\nbromodichlorometan (2,0 - 40) μg/l\ndibromochlorometan (2,0 - 40) μg/l\nbromoform (2,0 - 40) μg/l\nSuma THM (z obliczen)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 10301:2002","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Concentration of volatile organic compounds Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) chloroform (trichloromethane) bromodichloromethane dibromochloromethane bromoform Sum of THM (calculated) PN-EN ISO 10301:2002","search_zh":"游泳池水 挥发性有机物浓度 顶空气相色谱-质谱法（HS-GC-MS） 一溴二氯甲烷 二溴一氯甲烷 三溴甲烷 三卤甲烷总量（由计算得出） PN-EN ISO 10301:2002","test_object_zh":"游泳池水","parameters_zh":[{"name":"chloroform (trichlorometan)","range":"(2,0 - 40) μg/l"},{"name":"一溴二氯甲烷","range":"(2,0 - 40) μg/l"},{"name":"二溴一氯甲烷","range":"(2,0 - 40) μg/l"},{"name":"三溴甲烷","range":"(2,0 - 40) μg/l"},{"name":"三卤甲烷总量（由计算得出）"}],"technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","methodology_zh":"挥发性有机物浓度"},{"_id":"6a5dc9bef1c10c8ce825e95d","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"chlorany","range":"(0,010 - 1,0) mg/l"},{"name":"chloryny","range":"(0,010 - 1,0) mg/l"},{"name":"Suma chloranów i chlorynów (z obliczeń)"}],"parameters_en":[{"name":"chlorates","range":"(0,010 - 1,0) mg/l"},{"name":"chlorites","range":"(0,010 - 1,0) mg/l"},{"name":"Sum of chlorates and chlorites (calculated)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nchlorany (0,010 - 1,0) mg/l\nchloryny (0,010 - 1,0) mg/l\nSuma chloranów i chlorynów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022","norm_bases":["PN-EN ISO 10304-4:2022"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie anionów\nZakres:\nchlorany (0,010 - 1,0) mg/l\nchloryny (0,010 - 1,0) mg/l\nSuma chloranów i chlorynów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022 Woda, Woda do spozycia przez ludzi Stezenie anionow\nZakres:\nchlorany (0,010 - 1,0) mg/l\nchloryny (0,010 - 1,0) mg/l\nSuma chloranow i chlorynow (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) chlorates chlorites Sum of chlorates and chlorites (calculated) PN-EN ISO 10304-4:2022","methodology_zh":"阴离子浓度","search_zh":"水、生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯酸盐 亚氯酸盐 氯酸盐与亚氯酸盐总量（由计算得出） PN-EN ISO 10304-4:2022","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"氯酸盐","range":"(0,010 - 1,0) mg/l"},{"name":"亚氯酸盐","range":"(0,010 - 1,0) mg/l"},{"name":"氯酸盐与亚氯酸盐总量（由计算得出）"}]},{"_id":"6a5dc9bef1c10c8ce825e95e","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","test_object_en":"Water, Water intended for human consumption","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"arsen","range":"(0,0010 - 0,10) mg/l"},{"name":"antymon","range":"(0,0010 - 0,10) mg/l"},{"name":"bor 0,050 - 2,0) mg/l chrom","range":"(0,0010 - 0,10) mg/l"},{"name":"cynk","range":"(0,010 - 0,50) mg/l"},{"name":"glin","range":"(0,010 - 0,50) mg/l"},{"name":"kadm","range":"(0,0010 - 0,10)mg/l"},{"name":"miedź","range":"(0,010 - 2,0) mg/l"},{"name":"mangan","range":"(0,0050 - 0,50) mg/l"},{"name":"nikiel","range":"(0,0010 - 0,10) mg/l"},{"name":"ołów","range":"(0,0010 - 0,10) mg/l"},{"name":"selen","range":"(0,0010 - 0,10) mg/l"},{"name":"srebro","range":"(0,0010 - 0,10) mg/l"},{"name":"żelazo","range":"(0,010 – 2,0) mg/l"}],"parameters_en":[{"name":"arsenic","range":"(0,0010 - 0,10) mg/l"},{"name":"antimony","range":"(0,0010 - 0,10) mg/l"},{"name":"boron 0,050 - 2,0) mg/l chromium","range":"(0,0010 - 0,10) mg/l"},{"name":"zinc","range":"(0,010 - 0,50) mg/l"},{"name":"aluminium","range":"(0,010 - 0,50) mg/l"},{"name":"cadmium","range":"(0,0010 - 0,10)mg/l"},{"name":"copper","range":"(0,010 - 2,0) mg/l"},{"name":"manganese","range":"(0,0050 - 0,50) mg/l"},{"name":"nickel","range":"(0,0010 - 0,10) mg/l"},{"name":"lead","range":"(0,0010 - 0,10) mg/l"},{"name":"selenium","range":"(0,0010 - 0,10) mg/l"},{"name":"silver","range":"(0,0010 - 0,10) mg/l"},{"name":"iron","range":"(0,010 – 2,0) mg/l"}],"technique":"Metoda spektrometrii mas z plazmą wzbudzoną indukcyjnie (ICP-MS)","techniques":["Metoda spektrometrii mas z plazmą wzbudzoną indukcyjnie (ICP-MS)"],"technique_en":"Inductively coupled plasma mass spectrometry (ICP-MS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\narsen (0,0010 - 0,10) mg/l\nantymon (0,0010 - 0,10) mg/l\nbor 0,050 - 2,0) mg/l chrom (0,0010 - 0,10) mg/l\ncynk (0,010 - 0,50) mg/l\nglin (0,010 - 0,50) mg/l\nkadm (0,0010 - 0,10)mg/l\nmiedź (0,010 - 2,0) mg/l\nmangan (0,0050 - 0,50) mg/l\nnikiel (0,0010 - 0,10) mg/l\nołów (0,0010 - 0,10) mg/l\nselen (0,0010 - 0,10) mg/l\nsrebro (0,0010 - 0,10) mg/l\nżelazo (0,010 – 2,0) mg/l\nMetoda spektrometrii mas z plazmą wzbudzoną indukcyjnie (ICP-MS)","reference":"PN-EN ISO 17294-2: 2024-04","norm_bases":["PN-EN ISO 17294-2: 2024-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\narsen (0,0010 - 0,10) mg/l\nantymon (0,0010 - 0,10) mg/l\nbor 0,050 - 2,0) mg/l chrom (0,0010 - 0,10) mg/l\ncynk (0,010 - 0,50) mg/l\nglin (0,010 - 0,50) mg/l\nkadm (0,0010 - 0,10)mg/l\nmiedź (0,010 - 2,0) mg/l\nmangan (0,0050 - 0,50) mg/l\nnikiel (0,0010 - 0,10) mg/l\nołów (0,0010 - 0,10) mg/l\nselen (0,0010 - 0,10) mg/l\nsrebro (0,0010 - 0,10) mg/l\nżelazo (0,010 – 2,0) mg/l\nMetoda spektrometrii mas z plazmą wzbudzoną indukcyjnie (ICP-MS) PN-EN ISO 17294-2: 2024-04 Woda, Woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\narsen (0,0010 - 0,10) mg/l\nantymon (0,0010 - 0,10) mg/l\nbor 0,050 - 2,0) mg/l chrom (0,0010 - 0,10) mg/l\ncynk (0,010 - 0,50) mg/l\nglin (0,010 - 0,50) mg/l\nkadm (0,0010 - 0,10)mg/l\nmiedz (0,010 - 2,0) mg/l\nmangan (0,0050 - 0,50) mg/l\nnikiel (0,0010 - 0,10) mg/l\nolow (0,0010 - 0,10) mg/l\nselen (0,0010 - 0,10) mg/l\nsrebro (0,0010 - 0,10) mg/l\nzelazo (0,010 – 2,0) mg/l\nMetoda spektrometrii mas z plazma wzbudzona indukcyjnie (ICP-MS) PN-EN ISO 17294-2: 2024-04","categories":["water","materials"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Water intended for human consumption Element concentration Inductively coupled plasma mass spectrometry (ICP-MS) arsenic antimony boron 0,050 - 2,0) mg/l chromium zinc aluminium cadmium copper manganese nickel lead selenium silver iron PN-EN ISO 17294-2: 2024-04","methodology_zh":"元素浓度","parameters_zh":[{"name":"砷","range":"(0,0010 - 0,10) mg/l"},{"name":"锑","range":"(0,0010 - 0,10) mg/l"},{"name":"bor 0,050 - 2,0) mg/l chrom","range":"(0,0010 - 0,10) mg/l"},{"name":"锌","range":"(0,010 - 0,50) mg/l"},{"name":"铝","range":"(0,010 - 0,50) mg/l"},{"name":"镉","range":"(0,0010 - 0,10)mg/l"},{"name":"铜","range":"(0,010 - 2,0) mg/l"},{"name":"锰","range":"(0,0050 - 0,50) mg/l"},{"name":"镍","range":"(0,0010 - 0,10) mg/l"},{"name":"铅","range":"(0,0010 - 0,10) mg/l"},{"name":"硒","range":"(0,0010 - 0,10) mg/l"},{"name":"银","range":"(0,0010 - 0,10) mg/l"},{"name":"铁","range":"(0,010 – 2,0) mg/l"}],"search_zh":"水、生活饮用水 元素浓度 电感耦合等离子体质谱法（ICP-MS） 砷 锑 锌 铝 镉 铜 锰 镍 铅 硒 银 铁 PN-EN ISO 17294-2: 2024-04","test_object_zh":"水、生活饮用水","technique_zh":"电感耦合等离子体质谱法（ICP-MS）"},{"_id":"6a5dc9bef1c10c8ce825e95f","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie lotnych związków organicznych","methodology_en":"Concentration of volatile organic compounds","parameters":[{"name":"chloroform (trichlorometan)","range":"(2,0 - 40) μg/l"},{"name":"bromodichlorometan","range":"(2,0 - 40) μg/l"},{"name":"dibromochlorometan","range":"(2,0 - 40) μg/l"},{"name":"bromoform","range":"(2,0 - 40) μg/l"},{"name":"Suma THM (z obliczeń) trichloroeten","range":"(2,0 - 40) μg/l"},{"name":"tertachloroeten","range":"(2,0 - 40) μg/l"},{"name":"heksachloro-1,3-butadien","range":"(0,5 - 5,0) μg/l"},{"name":"Zakres","range":"1,2-dichloroetan (0,5 - 5,0) μg/l"},{"name":"Suma trichloroetenu i tetrachloroetenu (z obliczeń)"}],"parameters_en":[{"name":"chloroform (trichloromethane)","range":"(2,0 - 40) μg/l"},{"name":"bromodichloromethane","range":"(2,0 - 40) μg/l"},{"name":"dibromochloromethane","range":"(2,0 - 40) μg/l"},{"name":"bromoform","range":"(2,0 - 40) μg/l"},{"name":"Sum of THM (calculated) trichloroethene","range":"(2,0 - 40) μg/l"},{"name":"tetrachloroethene","range":"(2,0 - 40) μg/l"},{"name":"hexachloro-1,3-butadiene","range":"(0,5 - 5,0) μg/l"},{"name":"Range","range":"1,2-dichloroetan (0,5 - 5,0) μg/l"},{"name":"Sum of trichloroethene and tetrachloroethene (calculated)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie lotnych związków organicznych\nZakres:\nchloroform (trichlorometan) (2,0 - 40) μg/l\nbromodichlorometan (2,0 - 40) μg/l\ndibromochlorometan (2,0 - 40) μg/l\nbromoform (2,0 - 40) μg/l\nSuma THM (z obliczeń) trichloroeten (2,0 - 40) μg/l\ntertachloroeten (2,0 - 40) μg/l\nheksachloro-1,3-butadien (0,5 - 5,0) μg/l\nZakres 1,2-dichloroetan (0,5 - 5,0) μg/l\nSuma trichloroetenu i tetrachloroetenu (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie lotnych związków organicznych\nZakres:\nchloroform (trichlorometan) (2,0 - 40) μg/l\nbromodichlorometan (2,0 - 40) μg/l\ndibromochlorometan (2,0 - 40) μg/l\nbromoform (2,0 - 40) μg/l\nSuma THM (z obliczeń) trichloroeten (2,0 - 40) μg/l\ntertachloroeten (2,0 - 40) μg/l\nheksachloro-1,3-butadien (0,5 - 5,0) μg/l\nZakres 1,2-dichloroetan (0,5 - 5,0) μg/l\nSuma trichloroetenu i tetrachloroetenu (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-EN ISO 10301:2002 Woda, Scieki Stezenie lotnych zwiazkow organicznych\nZakres:\nchloroform (trichlorometan) (2,0 - 40) μg/l\nbromodichlorometan (2,0 - 40) μg/l\ndibromochlorometan (2,0 - 40) μg/l\nbromoform (2,0 - 40) μg/l\nSuma THM (z obliczen) trichloroeten (2,0 - 40) μg/l\ntertachloroeten (2,0 - 40) μg/l\nheksachloro-1,3-butadien (0,5 - 5,0) μg/l\nZakres 1,2-dichloroetan (0,5 - 5,0) μg/l\nSuma trichloroetenu i tetrachloroetenu (z obliczen)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-EN ISO 10301:2002","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of volatile organic compounds Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) chloroform (trichloromethane) bromodichloromethane dibromochloromethane bromoform Sum of THM (calculated) trichloroethene tetrachloroethene hexachloro-1,3-butadiene Range Sum of trichloroethene and tetrachloroethene (calculated) PN-EN ISO 10301:2002","parameters_zh":[{"name":"chloroform (trichlorometan)","range":"(2,0 - 40) μg/l"},{"name":"一溴二氯甲烷","range":"(2,0 - 40) μg/l"},{"name":"二溴一氯甲烷","range":"(2,0 - 40) μg/l"},{"name":"三溴甲烷","range":"(2,0 - 40) μg/l"},{"name":"Suma THM (z obliczeń) trichloroeten","range":"(2,0 - 40) μg/l"},{"name":"tertachloroeten","range":"(2,0 - 40) μg/l"},{"name":"heksachloro-1,3-butadien","range":"(0,5 - 5,0) μg/l"},{"name":"范围","range":"1,2-dichloroetan (0,5 - 5,0) μg/l"},{"name":"三氯乙烯与四氯乙烯总量（由计算得出）"}],"search_zh":"水、污水 挥发性有机物浓度 顶空气相色谱-质谱法（HS-GC-MS） 一溴二氯甲烷 二溴一氯甲烷 三溴甲烷 范围 三氯乙烯与四氯乙烯总量（由计算得出） PN-EN ISO 10301:2002","test_object_zh":"水、污水","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","methodology_zh":"挥发性有机物浓度"},{"_id":"6a5dc9bef1c10c8ce825e960","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie lotnych związków organicznych","methodology_en":"Concentration of volatile organic compounds","parameters":[{"name":"Zakres","range":"1,2,3-trichlorobenzen (2,0 - 20) μg/l"},{"name":"1,2,4-trichlorobenzen","range":"(2,0 - 20) μg/l"},{"name":"1,3,5-trichlorobenzen","range":"(2,0 - 20) μg/l"},{"name":"benzen","range":"(0,5 - 5,0) μg/l"},{"name":"Suma trichlorobenzenów (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"1,2,3-trichlorobenzen (2,0 - 20) μg/l"},{"name":"1,2,4-trichlorobenzene","range":"(2,0 - 20) μg/l"},{"name":"1,3,5-trichlorobenzene","range":"(2,0 - 20) μg/l"},{"name":"benzene","range":"(0,5 - 5,0) μg/l"},{"name":"Sum of trichlorobenzenes (calculated)"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)"],"technique_en":"Headspace gas chromatography with mass spectrometry detection (HS-GC-MS)","computed":[],"computed_en":[],"activity":"Stężenie lotnych związków organicznych\nZakres:\nZakres 1,2,3-trichlorobenzen (2,0 - 20) μg/l\n1,2,4-trichlorobenzen (2,0 - 20) μg/l\n1,3,5-trichlorobenzen (2,0 - 20) μg/l\nbenzen (0,5 - 5,0) μg/l\nSuma trichlorobenzenów (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS)","reference":"PN-ISO 11423-1:2002","norm_bases":["PN-ISO 11423-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie lotnych związków organicznych\nZakres:\nZakres 1,2,3-trichlorobenzen (2,0 - 20) μg/l\n1,2,4-trichlorobenzen (2,0 - 20) μg/l\n1,3,5-trichlorobenzen (2,0 - 20) μg/l\nbenzen (0,5 - 5,0) μg/l\nSuma trichlorobenzenów (z obliczeń)\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej i detekcją spektrometrią mas (HS-GC-MS) PN-ISO 11423-1:2002 Woda, Scieki Stezenie lotnych zwiazkow organicznych\nZakres:\nZakres 1,2,3-trichlorobenzen (2,0 - 20) μg/l\n1,2,4-trichlorobenzen (2,0 - 20) μg/l\n1,3,5-trichlorobenzen (2,0 - 20) μg/l\nbenzen (0,5 - 5,0) μg/l\nSuma trichlorobenzenow (z obliczen)\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej i detekcja spektrometria mas (HS-GC-MS) PN-ISO 11423-1:2002","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of volatile organic compounds Headspace gas chromatography with mass spectrometry detection (HS-GC-MS) Range 1,2,4-trichlorobenzene 1,3,5-trichlorobenzene benzene Sum of trichlorobenzenes (calculated) PN-ISO 11423-1:2002","parameters_zh":[{"name":"范围","range":"1,2,3-trichlorobenzen (2,0 - 20) μg/l"},{"name":"1,2,4-三氯苯","range":"(2,0 - 20) μg/l"},{"name":"1,3,5-三氯苯","range":"(2,0 - 20) μg/l"},{"name":"苯","range":"(0,5 - 5,0) μg/l"},{"name":"三氯苯总量（由计算得出）"}],"search_zh":"水、污水 挥发性有机物浓度 顶空气相色谱-质谱法（HS-GC-MS） 范围 1,2,4-三氯苯 1,3,5-三氯苯 苯 三氯苯总量（由计算得出） PN-ISO 11423-1:2002","test_object_zh":"水、污水","technique_zh":"顶空气相色谱-质谱法（HS-GC-MS）","methodology_zh":"挥发性有机物浓度"},{"_id":"6a5dc9bef1c10c8ce825e961","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie wybranych insektycydów chloroorganicznych","methodology_en":"Concentration of selected organochlorine insecticides","parameters":[{"name":"Alfa-HCH","range":"(0,02 - 0,2) ug/l"},{"name":"Beta-HCH","range":"(0,02 - 0,2) μg/l"},{"name":"Gamma-HCH","range":"(0,02 - 0,2) ug/l"},{"name":"Aldryna","range":"(0,02 - 0,2) μg/l"},{"name":"Dieldryna","range":"(0,02 - 0,2) μg/l"},{"name":"Endryna","range":"(0,02 - 0,2) μg/l"},{"name":"Izodryna","range":"(0,02 - 0,2) ug/l"},{"name":"Epoksyheptachlor","range":"(0,02 - 0,2) μg/l"},{"name":"Heksachlorobenzen","range":"(0,02 - 0,2) μg/l"},{"name":"Heptachlor","range":"(0,02 - 0,2) μg/l"},{"name":"Metoksychlor (DMDT)","range":"(0,02 - 0,2) ug/l"},{"name":"p,p’-DDT","range":"(0,02 - 0,2) μg/l"},{"name":"p,p’-DDE","range":"(0,02 - 0,2) μg/l"},{"name":"p,p’-DDD","range":"(0,02 - 0,2) μg/l"}],"parameters_en":[{"name":"Alpha-HCH","range":"(0,02 - 0,2) ug/l"},{"name":"Beta-HCH","range":"(0,02 - 0,2) μg/l"},{"name":"Gamma-HCH","range":"(0,02 - 0,2) ug/l"},{"name":"Aldrin","range":"(0,02 - 0,2) μg/l"},{"name":"Dieldrin","range":"(0,02 - 0,2) μg/l"},{"name":"Endrin","range":"(0,02 - 0,2) μg/l"},{"name":"Isodrin","range":"(0,02 - 0,2) ug/l"},{"name":"Heptachlor epoxide","range":"(0,02 - 0,2) μg/l"},{"name":"Hexachlorobenzene","range":"(0,02 - 0,2) μg/l"},{"name":"Heptachlor","range":"(0,02 - 0,2) μg/l"},{"name":"Methoxychlor (DMDT)","range":"(0,02 - 0,2) ug/l"},{"name":"p,p’-DDT","range":"(0,02 - 0,2) μg/l"},{"name":"p,p’-DDE","range":"(0,02 - 0,2) μg/l"},{"name":"p,p’-DDD","range":"(0,02 - 0,2) μg/l"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie wybranych insektycydów chloroorganicznych\nZakres:\nAlfa-HCH (0,02 - 0,2) ug/l\nBeta-HCH (0,02 - 0,2) μg/l\nGamma-HCH (0,02 - 0,2) ug/l\nAldryna (0,02 - 0,2) μg/l\nDieldryna (0,02 - 0,2) μg/l\nEndryna (0,02 - 0,2) μg/l\nIzodryna (0,02 - 0,2) ug/l\nEpoksyheptachlor (0,02 - 0,2) μg/l\nHeksachlorobenzen (0,02 - 0,2) μg/l\nHeptachlor (0,02 - 0,2) μg/l\nMetoksychlor (DMDT) (0,02 - 0,2) ug/l\np,p’-DDT (0,02 - 0,2) μg/l\np,p’-DDE (0,02 - 0,2) μg/l\np,p’-DDD (0,02 - 0,2) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie wybranych insektycydów chloroorganicznych\nZakres:\nAlfa-HCH (0,02 - 0,2) ug/l\nBeta-HCH (0,02 - 0,2) μg/l\nGamma-HCH (0,02 - 0,2) ug/l\nAldryna (0,02 - 0,2) μg/l\nDieldryna (0,02 - 0,2) μg/l\nEndryna (0,02 - 0,2) μg/l\nIzodryna (0,02 - 0,2) ug/l\nEpoksyheptachlor (0,02 - 0,2) μg/l\nHeksachlorobenzen (0,02 - 0,2) μg/l\nHeptachlor (0,02 - 0,2) μg/l\nMetoksychlor (DMDT) (0,02 - 0,2) ug/l\np,p’-DDT (0,02 - 0,2) μg/l\np,p’-DDE (0,02 - 0,2) μg/l\np,p’-DDD (0,02 - 0,2) μg/l\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda, Scieki Stezenie wybranych insektycydow chloroorganicznych\nZakres:\nAlfa-HCH (0,02 - 0,2) ug/l\nBeta-HCH (0,02 - 0,2) μg/l\nGamma-HCH (0,02 - 0,2) ug/l\nAldryna (0,02 - 0,2) μg/l\nDieldryna (0,02 - 0,2) μg/l\nEndryna (0,02 - 0,2) μg/l\nIzodryna (0,02 - 0,2) ug/l\nEpoksyheptachlor (0,02 - 0,2) μg/l\nHeksachlorobenzen (0,02 - 0,2) μg/l\nHeptachlor (0,02 - 0,2) μg/l\nMetoksychlor (DMDT) (0,02 - 0,2) ug/l\np,p’-DDT (0,02 - 0,2) μg/l\np,p’-DDE (0,02 - 0,2) μg/l\np,p’-DDD (0,02 - 0,2) μg/l\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of selected organochlorine insecticides Gas chromatography with electron capture detection (GC-ECD) Alpha-HCH Beta-HCH Gamma-HCH Aldrin Dieldrin Endrin Isodrin Heptachlor epoxide Hexachlorobenzene Heptachlor Methoxychlor (DMDT) p,p’-DDT p,p’-DDE p,p’-DDD PN-EN ISO 6468:2002","search_zh":"水、污水 气相色谱-电子捕获检测法（GC-ECD） 艾氏剂 狄氏剂 异狄氏剂 异艾氏剂 六氯苯 七氯 p,p'-滴滴涕（DDT） p,p'-滴滴伊（DDE） p,p'-滴滴滴（DDD） PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水、污水","parameters_zh":[{"name":"Alfa-HCH","range":"(0,02 - 0,2) ug/l"},{"name":"Beta-HCH","range":"(0,02 - 0,2) μg/l"},{"name":"Gamma-HCH","range":"(0,02 - 0,2) ug/l"},{"name":"艾氏剂","range":"(0,02 - 0,2) μg/l"},{"name":"狄氏剂","range":"(0,02 - 0,2) μg/l"},{"name":"异狄氏剂","range":"(0,02 - 0,2) μg/l"},{"name":"异艾氏剂","range":"(0,02 - 0,2) ug/l"},{"name":"Epoksyheptachlor","range":"(0,02 - 0,2) μg/l"},{"name":"六氯苯","range":"(0,02 - 0,2) μg/l"},{"name":"七氯","range":"(0,02 - 0,2) μg/l"},{"name":"Metoksychlor (DMDT)","range":"(0,02 - 0,2) ug/l"},{"name":"p,p'-滴滴涕（DDT）","range":"(0,02 - 0,2) μg/l"},{"name":"p,p'-滴滴伊（DDE）","range":"(0,02 - 0,2) μg/l"},{"name":"p,p'-滴滴滴（DDD）","range":"(0,02 - 0,2) μg/l"}]},{"_id":"6a5dc9bef1c10c8ce825e962","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ogólnego węgla organicznego (OWO)","methodology_en":"Total organic carbon concentration (TOC)","parameters":[{"name":"Zakres","range":"(0,5 - 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,5 - 100) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni IR","techniques":["Metoda spektrometrii w podczerwieni IR"],"technique_en":"Infrared spectrometry IR","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (0,5 - 100) mg/l\nMetoda spektrometrii w podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ogólnego węgla organicznego (OWO)\nZakres (0,5 - 100) mg/l\nMetoda spektrometrii w podczerwieni IR PN-EN 1484:1999 Woda, Scieki Stezenie ogolnego wegla organicznego (OWO)\nZakres (0,5 - 100) mg/l\nMetoda spektrometrii w podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total organic carbon concentration (TOC) Infrared spectrometry IR Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(0,5 - 100) mg/l"}],"search_zh":"水、污水 总有机碳浓度（TOC） 范围 PN-EN 1484:1999","test_object_zh":"水、污水","methodology_zh":"总有机碳浓度（TOC）"},{"_id":"6a5dc9bef1c10c8ce825e963","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,3 - 5,0) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,3 - 5,0) μg/l"}],"technique":"Metoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji","techniques":["Metoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji"],"technique_en":"Atomic absorption spectrometry with amalgamation technique","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,3 - 5,0) μg/l\nMetoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji","reference":"PB-W-38 wydanie 4 z dnia 08.10.2025 r.","norm_bases":["PB-W-38 wydanie 4 z dnia 08.10.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie rtęci\nZakres (0,3 - 5,0) μg/l\nMetoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji PB-W-38 wydanie 4 z dnia 08.10.2025 r. Woda Stezenie rteci\nZakres (0,3 - 5,0) μg/l\nMetoda atomowej spektrometrii absorpcyjnej z technika amalgamacji PB-W-38 wydanie 4 z dnia 08.10.2025 r.","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Mercury concentration Atomic absorption spectrometry with amalgamation technique Range PB-W-38 wydanie 4 z dnia 08.10.2025 r.","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,3 - 5,0) μg/l"}],"search_zh":"水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 PB-W-38 wydanie 4 z dnia 08.10.2025 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e964","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie rtęci","methodology_en":"Mercury concentration","parameters":[{"name":"Zakres","range":"(0,4 - 5,0) μg/l"}],"parameters_en":[{"name":"Range","range":"(0,4 - 5,0) μg/l"}],"technique":"Metoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji","techniques":["Metoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji"],"technique_en":"Atomic absorption spectrometry with amalgamation technique","computed":[],"computed_en":[],"activity":"Stężenie rtęci\nZakres (0,4 - 5,0) μg/l\nMetoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji","reference":"PB-W-38 wydanie 4 z dnia 08.10.2025 r.","norm_bases":["PB-W-38 wydanie 4 z dnia 08.10.2025 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie rtęci\nZakres (0,4 - 5,0) μg/l\nMetoda atomowej spektrometrii absorpcyjnej z techniką amalgamacji PB-W-38 wydanie 4 z dnia 08.10.2025 r. Scieki Stezenie rteci\nZakres (0,4 - 5,0) μg/l\nMetoda atomowej spektrometrii absorpcyjnej z technika amalgamacji PB-W-38 wydanie 4 z dnia 08.10.2025 r.","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Mercury concentration Atomic absorption spectrometry with amalgamation technique Range PB-W-38 wydanie 4 z dnia 08.10.2025 r.","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,4 - 5,0) μg/l"}],"search_zh":"污水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 PB-W-38 wydanie 4 z dnia 08.10.2025 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"污水"},{"_id":"6a5dc9bef1c10c8ce825e965","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie:","methodology_en":"Concentration:","parameters":[{"name":"4-Nonylofenolu (0,1 - 10) μg/l"},{"name":"Bisfenolu A (0,1 - 10) μg/l 17β-Estradiolu (0,1 - 10) μg/l"}],"parameters_en":[{"name":"4-Nonylphenol (0,1 - 10) μg/l"},{"name":"Bisphenol A (0,1 - 10) μg/l 17β-Estradiol (0,1 - 10) μg/l"}],"technique":"Metoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS)"],"technique_en":"Liquid chromatography with tandem mass spectrometry (LC-MS-MS)","computed":[],"computed_en":[],"activity":"Stężenie:\nZakres:\n4-Nonylofenolu (0,1 - 10) μg/l\nBisfenolu A (0,1 - 10) μg/l 17β-Estradiolu (0,1 - 10) μg/l\nMetoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS)","reference":"PB-W-41 wydanie 1 z dnia 01.10.2023 r. z wyłączeniem pkt. 3.4.1","norm_bases":["PB-W-41 wydanie 1 z dnia 01.10.2023 r. z wyłączeniem pkt. 3.4.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie:\nZakres:\n4-Nonylofenolu (0,1 - 10) μg/l\nBisfenolu A (0,1 - 10) μg/l 17β-Estradiolu (0,1 - 10) μg/l\nMetoda chromatografii cieczowej z tandemową spektrometrią mas (LC-MS-MS) PB-W-41 wydanie 1 z dnia 01.10.2023 r. z wyłączeniem pkt. 3.4.1 Woda, woda do spozycia przez ludzi Stezenie:\nZakres:\n4-Nonylofenolu (0,1 - 10) μg/l\nBisfenolu A (0,1 - 10) μg/l 17β-Estradiolu (0,1 - 10) μg/l\nMetoda chromatografii cieczowej z tandemowa spektrometria mas (LC-MS-MS) PB-W-41 wydanie 1 z dnia 01.10.2023 r. z wylaczeniem pkt. 3.4.1","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Concentration: Liquid chromatography with tandem mass spectrometry (LC-MS-MS) 4-Nonylphenol (0,1 - 10) μg/l Bisphenol A (0,1 - 10) μg/l 17β-Estradiol (0,1 - 10) μg/l PB-W-41 wydanie 1 z dnia 01.10.2023 r. z wyłączeniem pkt. 3.4.1","search_zh":"水、生活饮用水 浓度： 液相色谱-串联质谱法（LC-MS-MS） PB-W-41 wydanie 1 z dnia 01.10.2023 r. z wyłączeniem pkt. 3.4.1","test_object_zh":"水、生活饮用水","methodology_zh":"浓度：","technique_zh":"液相色谱-串联质谱法（LC-MS-MS）"},{"_id":"6a5dc9bef1c10c8ce825e966","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie:","methodology_en":"Concentration:","parameters":[{"name":"4-Nonylofenolu (0,4 – 40) ng/l"},{"name":"Bisfenolu A (0,4 – 40) ng/l 17β-Estradiolu (0,4 – 40) ng/l"}],"parameters_en":[{"name":"4-Nonylphenol (0,4 – 40) ng/l"},{"name":"Bisphenol A (0,4 – 40) ng/l 17β-Estradiol (0,4 – 40) ng/l"}],"technique":"Metoda chromatografii cieczowej z tandemową spektrometrią mas (SPE-LC-MS-MS)","techniques":["Metoda chromatografii cieczowej z tandemową spektrometrią mas (SPE-LC-MS-MS)"],"technique_en":"Liquid chromatography with tandem mass spectrometry (SPE-LC-MS-MS)","computed":[],"computed_en":[],"activity":"Stężenie:\nZakres:\n4-Nonylofenolu (0,4 – 40) ng/l\nBisfenolu A (0,4 – 40) ng/l 17β-Estradiolu (0,4 – 40) ng/l\nMetoda chromatografii cieczowej z tandemową spektrometrią mas (SPE-LC-MS-MS)","reference":"PB-W-41 wydanie 1 z dnia 01.10.2023 r.","norm_bases":["PB-W-41 wydanie 1 z dnia 01.10.2023 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie:\nZakres:\n4-Nonylofenolu (0,4 – 40) ng/l\nBisfenolu A (0,4 – 40) ng/l 17β-Estradiolu (0,4 – 40) ng/l\nMetoda chromatografii cieczowej z tandemową spektrometrią mas (SPE-LC-MS-MS) PB-W-41 wydanie 1 z dnia 01.10.2023 r. Woda, woda do spozycia przez ludzi Stezenie:\nZakres:\n4-Nonylofenolu (0,4 – 40) ng/l\nBisfenolu A (0,4 – 40) ng/l 17β-Estradiolu (0,4 – 40) ng/l\nMetoda chromatografii cieczowej z tandemowa spektrometria mas (SPE-LC-MS-MS) PB-W-41 wydanie 1 z dnia 01.10.2023 r.","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Concentration: Liquid chromatography with tandem mass spectrometry (SPE-LC-MS-MS) 4-Nonylphenol (0,4 – 40) ng/l Bisphenol A (0,4 – 40) ng/l 17β-Estradiol (0,4 – 40) ng/l PB-W-41 wydanie 1 z dnia 01.10.2023 r.","search_zh":"水、生活饮用水 浓度： PB-W-41 wydanie 1 z dnia 01.10.2023 r.","test_object_zh":"水、生活饮用水","methodology_zh":"浓度："},{"_id":"6a5dc9bef1c10c8ce825e967","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"水 微生物检测用样品采集 PN-EN ISO 19458:2007","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e968","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 5 (pożywka BCYE), Procedura 7 (pożywka GVPC)","methodology_en":"Count of bacteria of the genus Legionella, Matrix A, Procedure 5 (BCYE medium), Procedure 7 (GVPC medium)","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 5 (pożywka BCYE), Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 5 (pożywka BCYE), Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 5 (pozywka BCYE), Procedura 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Count of bacteria of the genus Legionella, Matrix A, Procedure 5 (BCYE medium), Procedure 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12","search_zh":"水 膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e969","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 7 (pożywka GVPC)","methodology_en":"Count of bacteria of the genus Legionella, Matrix B, Procedure 7 (medium GVPC)","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Count of bacteria of the genus Legionella, Matrix B, Procedure 7 (medium GVPC) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12","search_zh":"水 膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e96a","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 1 (pożywka BCYE i BCYE+AB)","methodology_en":"Count of bacteria of the genus Legionella, Matrix A, Procedure 1 (BCYE and BCYE+AB medium)","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"technique_en":"Plate method (spread plate)","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 1 (pożywka BCYE i BCYE+AB)\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 1 (pożywka BCYE i BCYE+AB)\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 1 (pozywka BCYE i BCYE+AB)\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Count of bacteria of the genus Legionella, Matrix A, Procedure 1 (BCYE and BCYE+AB medium) Plate method (spread plate) PN-EN ISO 11731:2017-08 +Ap1:2019-12","search_zh":"水 平板法（表面涂布） PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"平板法（表面涂布）","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e96b","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 1,2,3 (pożywka GVPC)","methodology_en":"Count of bacteria of the genus Legionella, Matrix B, Procedure 1,2,3 (GVPC medium)","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"technique_en":"Plate method (spread plate)","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 1,2,3 (pożywka GVPC)\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 1,2,3 (pożywka GVPC)\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 1,2,3 (pozywka GVPC)\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Count of bacteria of the genus Legionella, Matrix B, Procedure 1,2,3 (GVPC medium) Plate method (spread plate) PN-EN ISO 11731:2017-08 +Ap1:2019-12","search_zh":"水 平板法（表面涂布） PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"平板法（表面涂布）","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e96c","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba bakterii z grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba bakterii z grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba bakterii z grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","search_zh":"水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水","methodology_zh":"大肠菌群计数"},{"_id":"6a5dc9bef1c10c8ce825e96d","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e96e","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów na agarze odżywczym w temp. 22 °C","methodology_en":"Total count of microorganisms on nutrient agar at 22 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"technique_en":"Plate method, pour plate","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów na agarze odżywczym w temp. 22 °C\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów na agarze odżywczym w temp. 22 °C\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow na agarze odzywczym w temp. 22 °C\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total count of microorganisms on nutrient agar at 22 °C Plate method, pour plate PN-EN ISO 6222:2004","search_zh":"水 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"水","technique_zh":"平板法，倾注平板"},{"_id":"6a5dc9bef1c10c8ce825e96f","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Ogólna liczba mikroorganizmów na agarze odżywczym w temp. 36 °C","methodology_en":"Total count of microorganisms on nutrient agar at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"technique_en":"Plate method, pour plate","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów na agarze odżywczym w temp. 36 °C\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Ogólna liczba mikroorganizmów na agarze odżywczym w temp. 36 °C\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow na agarze odzywczym w temp. 36 °C\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total count of microorganisms on nutrient agar at 36 °C Plate method, pour plate PN-EN ISO 6222:2004","search_zh":"水 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"水","technique_zh":"平板法，倾注平板"},{"_id":"6a5dc9bef1c10c8ce825e970","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba paciorkowców kałowych","methodology_en":"Faecal streptococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba paciorkowców kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba paciorkowców kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba paciorkowcow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Faecal streptococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水 粪链球菌数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水","methodology_zh":"粪链球菌数"},{"_id":"6a5dc9bef1c10c8ce825e971","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Clostridium perfringens łącznie z przetrwalnikami","methodology_en":"Clostridium perfringens count including spores","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda Liczba Clostridium perfringens lacznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a5dc9bef1c10c8ce825e972","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e973","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba bakterii z grupy coli","methodology_en":"Most probable number of coliform bacteria","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii z grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-02:2014","norm_bases":["PN-EN ISO 9308-02:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba bakterii z grupy coli\nMetoda NPL PN-EN ISO 9308-02:2014 Woda Najbardziej prawdopodobna liczba bakterii z grupy coli\nMetoda NPL PN-EN ISO 9308-02:2014","categories":["water","microbiology"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Most probable number of coliform bacteria MPN method PN-EN ISO 9308-02:2014","search_zh":"水 大肠菌群最可能数 最可能数法（MPN） PN-EN ISO 9308-02:2014","technique_zh":"最可能数法（MPN）","test_object_zh":"水","methodology_zh":"大肠菌群最可能数"},{"_id":"6a5dc9bef1c10c8ce825e974","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-02:2014","norm_bases":["PN-EN ISO 9308-02:2014"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-02:2014 Woda Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-02:2014","categories":["water","microbiology"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Most probable number, Escherichia coli MPN method PN-EN ISO 9308-02:2014","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-02:2014","technique_zh":"最可能数法（MPN）","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e975","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Najbardziej prawdopodobna liczba bakterii z grupy coli typu kałowego","methodology_en":"Most probable number of faecal coliform bacteria","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii z grupy coli typu kałowego\nMetoda NPL","reference":"PB-B-08 wydanie 3 z dnia 10.08.2021 r. | na podstawie instrukcji obsługi testu Colilert","norm_bases":["PB-B-08 wydanie 3 z dnia 10.08.2021 r.","na podstawie instrukcji obsługi testu Colilert"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Najbardziej prawdopodobna liczba bakterii z grupy coli typu kałowego\nMetoda NPL PB-B-08 wydanie 3 z dnia 10.08.2021 r. | na podstawie instrukcji obsługi testu Colilert Woda Najbardziej prawdopodobna liczba bakterii z grupy coli typu kalowego\nMetoda NPL PB-B-08 wydanie 3 z dnia 10.08.2021 r. | na podstawie instrukcji obslugi testu Colilert","categories":["water","microbiology"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Most probable number of faecal coliform bacteria MPN method PB-B-08 wydanie 3 z dnia 10.08.2021 r. | na podstawie instrukcji obsługi testu Colilert","search_zh":"水 最可能数法（MPN） PB-B-08 wydanie 3 z dnia 10.08.2021 r. | na podstawie instrukcji obsługi testu Colilert","technique_zh":"最可能数法（MPN）","test_object_zh":"水"},{"_id":"6a5dc9bef1c10c8ce825e976","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Liczba colifagów somatycznych","methodology_en":"Somatic coliphage count","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Liczba colifagów somatycznych\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 10705-2:2005","norm_bases":["PN-EN ISO 10705-2:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Liczba colifagów somatycznych\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 10705-2:2005 Woda Liczba colifagow somatycznych\nMetoda plytkowa (posiew wglebny) PN-EN ISO 10705-2:2005","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Somatic coliphage count Plate method (pour plate) PN-EN ISO 10705-2:2005","search_zh":"水 体细胞噬菌体数 平板法（倾注培养） PN-EN ISO 10705-2:2005","technique_zh":"平板法（倾注培养）","test_object_zh":"水","methodology_zh":"体细胞噬菌体数"},{"_id":"6a5dc9bef1c10c8ce825e977","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Liczba Gronkowców koagulazododatnich","methodology_en":"Coagulase-positive Staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"PN-Z -11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1","norm_bases":["PN-Z -11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Liczba Gronkowców koagulazododatnich\nMetoda filtracji membranowej PN-Z -11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1 Woda do spozycia przez ludzi Liczba Gronkowcow koagulazododatnich\nMetoda filtracji membranowej PN-Z -11001-3:2000 zalacznik A z wylaczeniem pkt. A.5.2.1","categories":["water"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Coagulase-positive Staphylococci count Membrane filtration method PN-Z -11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1","search_zh":"生活饮用水 凝固酶阳性葡萄球菌数 膜过滤法 PN-Z -11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"凝固酶阳性葡萄球菌数"},{"_id":"6a5dc9bef1c10c8ce825e978","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Ogólna liczba mikroorganizmów na agarze odżywczym w temp. 36 °C","methodology_en":"Total count of microorganisms on nutrient agar at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"technique_en":"Plate method, pour plate","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów na agarze odżywczym w temp. 36 °C\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów na agarze odżywczym w temp. 36 °C\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow na agarze odzywczym w temp. 36 °C\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Total count of microorganisms on nutrient agar at 36 °C Plate method, pour plate PN-EN ISO 6222:2004","search_zh":"游泳池水 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"游泳池水","technique_zh":"平板法，倾注平板"},{"_id":"6a5dc9bef1c10c8ce825e979","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bef1c10c8ce825e97a","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 5 (pożywka BCYE), 7 (pożywka GVPC)","methodology_en":"Count of bacteria of the genus Legionella, Matrix A, Procedure 5 (BCYE medium), 7 (GVPC medium)","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 5 (pożywka BCYE), 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 5 (pożywka BCYE), 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda na plywalniach Liczba bakterii z rodzaju Legionella, Matryca A, Procedura 5 (pozywka BCYE), 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Count of bacteria of the genus Legionella, Matrix A, Procedure 5 (BCYE medium), 7 (GVPC medium) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12","search_zh":"游泳池水 军团菌属细菌数，基质 A，程序 5（培养基 BCYE）、7（培养基 GVPC） 膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"军团菌属细菌数，基质 A，程序 5（培养基 BCYE）、7（培养基 GVPC）"},{"_id":"6a5dc9bef1c10c8ce825e97b","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 7 (pożywka GVPC)","methodology_en":"Count of bacteria of the genus Legionella, Matrix B, Procedure 7 (medium GVPC)","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda na plywalniach Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Count of bacteria of the genus Legionella, Matrix B, Procedure 7 (medium GVPC) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12","search_zh":"游泳池水 膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bef1c10c8ce825e97c","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bef1c10c8ce825e97d","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Gronkowców koagulazododatnich","methodology_en":"Coagulase-positive Staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1","norm_bases":["PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Gronkowców koagulazododatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1 Woda na plywalniach Liczba Gronkowcow koagulazododatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 zalacznik A z wylaczeniem pkt. A.5.2.1","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Coagulase-positive Staphylococci count Membrane filtration method PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1","search_zh":"游泳池水 凝固酶阳性葡萄球菌数 膜过滤法 PN-Z-11001-3:2000 załącznik A z wyłączeniem pkt. A.5.2.1","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌数"},{"_id":"6a5dc9bef1c10c8ce825e97e","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Odpady, kod: 19 08 05, 19 09 02","test_object_en":"Waste, code: 19 08 05, 19 09 02","methodology":"Obecność bakterii z rodzaju, Salmonella","methodology_en":"Presence of bacteria of the genus, Salmonella","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność bakterii z rodzaju, Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 +A1:2020-09","norm_bases":["PN-EN ISO 6579-1:2017-04 +A1:2020-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady, kod: 19 08 05, 19 09 02 Obecność bakterii z rodzaju, Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09 Odpady, kod: 19 08 05, 19 09 02 Obecnosc bakterii z rodzaju, Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 +A1:2020-09","categories":["microbiology","environment"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste, code: 19 08 05, 19 09 02 Presence of bacteria of the genus, Salmonella Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 +A1:2020-09","search_zh":"沙门氏菌属细菌的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 +A1:2020-09","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"沙门氏菌属细菌的检出"},{"_id":"6a5dc9bef1c10c8ce825e97f","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(0,5 – 50,0) °C"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(0,5 – 50,0) °C"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"technique_en":"Manual and automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,5 – 50,0) °C\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,5 – 50,0) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (0,5 – 50,0) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(0,5 – 50,0) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手工与自动法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a5dc9bef1c10c8ce825e980","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Wody opadowe","test_object_en":"Rainwater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki"},{"name":"Zakres","range":"(0,5 – 50,0)°C"}],"parameters_en":[{"name":"Temperature of the collected sample"},{"name":"Range","range":"(0,5 – 50,0)°C"}],"technique":"Metoda manualna","techniques":["Metoda manualna"],"technique_en":"Manual method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki\nZakres (0,5 – 50,0)°C\nMetoda manualna","reference":"PN-ISO 5667-10: 2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10: 2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki\nZakres (0,5 – 50,0)°C\nMetoda manualna PN-ISO 5667-10: 2021-11 | PN-77/C-04584 Wody opadowe Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki\nZakres (0,5 – 50,0)°C\nMetoda manualna PN-ISO 5667-10: 2021-11 | PN-77/C-04584","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rainwater Sampling for chemical and physical testing Manual method Temperature of the collected sample Range PN-ISO 5667-10: 2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采样品的温度"},{"name":"范围","range":"(0,5 – 50,0)°C"}],"search_zh":"化学与物理检测用样品采集 手工法 所采样品的温度 范围 PN-ISO 5667-10: 2021-11 | PN-77/C-04584","technique_zh":"手工法"},{"_id":"6a5dc9bef1c10c8ce825e981","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki, wody opadowe","test_object_en":"Water, Wastewater, rainwater","methodology":"Stężenie azotu ogólnego","methodology_en":"Total nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 – 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 2000) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","techniques":["Metoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną"],"technique_en":"High-temperature combustion with chemiluminescence detection","computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego\nZakres (1,0 – 2000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną","reference":"PN-EN ISO 20236:2025-04","norm_bases":["PN-EN ISO 20236:2025-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki, wody opadowe Stężenie azotu ogólnego\nZakres (1,0 – 2000) mg/l\nMetoda wysokotemperaturowego spalania z detekcją chemiluminescencyjną PN-EN ISO 20236:2025-04 Woda, Scieki, wody opadowe Stezenie azotu ogolnego\nZakres (1,0 – 2000) mg/l\nMetoda wysokotemperaturowego spalania z detekcja chemiluminescencyjna PN-EN ISO 20236:2025-04","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater, rainwater Total nitrogen concentration High-temperature combustion with chemiluminescence detection Range PN-EN ISO 20236:2025-04","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 2000) mg/l"}],"search_zh":"水、废水、雨水 总氮浓度 高温燃烧-化学发光检测法 范围 PN-EN ISO 20236:2025-04","technique_zh":"高温燃烧-化学发光检测法","test_object_zh":"水、废水、雨水"},{"_id":"6a5dc9bef1c10c8ce825e982","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki, wody opadowe","test_object_en":"Water, Wastewater, rainwater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT - Cr"},{"name":"Zakres","range":"(10,0 - 15000) mg/l O2"}],"parameters_en":[{"name":"COD - Cr"},{"name":"Range","range":"(10,0 - 15000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT - Cr\nZakres (10,0 - 15000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki, wody opadowe Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT - Cr\nZakres (10,0 - 15000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki, wody opadowe Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT - Cr\nZakres (10,0 - 15000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater, rainwater Chemical oxygen demand Spectrophotometric method COD - Cr Range PN-ISO 15705:2005","parameters_zh":[{"name":"COD-Cr"},{"name":"范围","range":"(10,0 - 15000) mg/l O2"}],"search_zh":"水、废水、雨水 化学需氧量（COD） 分光光度法 COD-Cr 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","methodology_zh":"化学需氧量（COD）","test_object_zh":"水、废水、雨水"},{"_id":"6a5dc9bef1c10c8ce825e983","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki, wody opadowe","test_object_en":"Water, Wastewater, rainwater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,010 - 80,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 - 80,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,010 - 80,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki, wody opadowe Stężenie fosforu ogólnego\nZakres (0,010 - 80,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010 Woda, Scieki, wody opadowe Stezenie fosforu ogolnego\nZakres (0,010 - 80,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010","categories":["water"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater, rainwater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,010 - 80,0) mg/l"}],"search_zh":"水、废水、雨水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水、雨水"},{"_id":"6a5dc9bef1c10c8ce825e984","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki, wody opadowe","test_object_en":"Water, Wastewater, rainwater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 - 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 - 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 - 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki, wody opadowe Zawiesiny ogólne\nZakres (2,0 - 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki, wody opadowe Zawiesiny ogolne\nZakres (2,0 - 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater, rainwater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 - 2000) mg/l"}],"search_zh":"水、废水、雨水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水、雨水"},{"_id":"6a5dc9bef1c10c8ce825e985","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki, wody opadowe","test_object_en":"Water, Wastewater, rainwater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(4,0 - 3500) mg/l"}],"parameters_en":[{"name":"Range","range":"(4,0 - 3500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (4,0 - 3500) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki, wody opadowe Stężenie chlorków\nZakres (4,0 - 3500) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki, wody opadowe Stezenie chlorkow\nZakres (4,0 - 3500) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater, rainwater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(4,0 - 3500) mg/l"}],"search_zh":"水、废水、雨水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水、雨水"},{"_id":"6a5dc9bef1c10c8ce825e986","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,2 - 560) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,2 - 560) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (1,2 - 560) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (1,2 - 560) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (1,2 - 560) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,2 - 560) mg/l"}],"search_zh":"水、污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e987","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,04 - 25) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,04 - 25) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,04 - 25) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,04 - 25) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, Scieki Stezenie azotu azotanowego\nZakres (0,04 - 25) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,04 - 25) mg/l"}],"search_zh":"水、污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e988","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,010 - 80,0) mg/l P-PO4"}],"parameters_en":[{"name":"Range","range":"(0,010 - 80,0) mg/l P-PO4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,010 - 80,0) mg/l P-PO4\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ortofosforanów\nZakres (0,010 - 80,0) mg/l P-PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie ortofosforanow\nZakres (0,010 - 80,0) mg/l P-PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010","categories":["water"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,010 - 80,0) mg/l P-PO4"}],"search_zh":"水、污水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9bef1c10c8ce825e989","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"3,0 - 12,0"}],"parameters_en":[{"name":"Range","range":"3,0 - 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 3,0 - 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki pH\nZakres 3,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres 3,0 - 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"3,0 - 12,0"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e98a","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,100 - 20,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,100 - 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,100 - 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,100 - 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,100 - 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,100 - 20,0) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e98b","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,24 - 20,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,24 - 20,0) mg/l"}],"technique":"Metoda spektrometryczna","techniques":["Metoda spektrometryczna"],"technique_en":"Spectrometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,24 - 20,0) mg/l\nMetoda spektrometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (0,24 - 20,0) mg/l\nMetoda spektrometryczna PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (0,24 - 20,0) mg/l\nMetoda spektrometryczna PN-EN 25663:2001","categories":["water"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Kjeldahl nitrogen concentration Spectrometric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,24 - 20,0) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 光谱法 范围 PN-EN 25663:2001","test_object_zh":"水、污水","technique_zh":"光谱法"},{"_id":"6a5dc9bef1c10c8ce825e98c","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(3,0 - 280) mg/l"}],"parameters_en":[{"name":"Range","range":"(3,0 - 280) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (3,0 - 280) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (3,0 - 280) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (3,0 - 280) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(3,0 - 280) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e98d","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73C-04576/14","norm_bases":["PN-73C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73C-04576/14 Woda, Scieki Stezenie azotu ogolnego (z obliczen) PN-73C-04576/14","categories":["water"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PN-73C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PN-73C-04576/14","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e98e","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowania tlenu BZT5","methodology_en":"Biochemical oxygen demand BOD5","parameters":[{"name":"Zakres","range":"(6,0 - 4000) mg /l O2"}],"parameters_en":[{"name":"Range","range":"(6,0 - 4000) mg /l O2"}],"technique":"Metoda manometryczna","techniques":["Metoda manometryczna"],"technique_en":"Manometric method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowania tlenu BZT5\nZakres (6,0 - 4000) mg /l O2\nMetoda manometryczna","reference":"PB-S-04 wydanie 2 z dnia 04.01.2021 r.","norm_bases":["PB-S-04 wydanie 2 z dnia 04.01.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowania tlenu BZT5\nZakres (6,0 - 4000) mg /l O2\nMetoda manometryczna PB-S-04 wydanie 2 z dnia 04.01.2021 r. Woda, Scieki Biochemiczne zapotrzebowania tlenu BZT5\nZakres (6,0 - 4000) mg /l O2\nMetoda manometryczna PB-S-04 wydanie 2 z dnia 04.01.2021 r.","categories":["water","metrology"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand BOD5 Manometric method Range PB-S-04 wydanie 2 z dnia 04.01.2021 r.","parameters_zh":[{"name":"范围","range":"(6,0 - 4000) mg /l O2"}],"search_zh":"水、污水 压力计法 范围 PB-S-04 wydanie 2 z dnia 04.01.2021 r.","test_object_zh":"水、污水","technique_zh":"压力计法"},{"_id":"6a5dc9bef1c10c8ce825e98f","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowania tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,5 - 6,0) mg /l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,5 - 6,0) mg /l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowania tlenu\nZakres:\nBZT5\nZakres (0,5 - 6,0) mg /l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowania tlenu\nZakres:\nBZT5\nZakres (0,5 - 6,0) mg /l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowania tlenu\nZakres:\nBZT5\nZakres (0,5 - 6,0) mg /l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,5 - 6,0) mg /l O2"}],"search_zh":"水、污水 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e990","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,005 - 24,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,005 - 24,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,005 - 24,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-S-10 wydanie 2 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8047","norm_bases":["PB-S-10 wydanie 2 z dnia 04.01.2021 r.","na podstawie testu kuwetowego HACH nr 8047"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,005 - 24,0) mg/l\nMetoda spektrofotometryczna PB-S-10 wydanie 2 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8047 Woda, Scieki Indeks fenolowy\nZakres (0,005 - 24,0) mg/l\nMetoda spektrofotometryczna PB-S-10 wydanie 2 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8047","categories":["water"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Phenol index Spectrophotometric method Range PB-S-10 wydanie 2 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8047","parameters_zh":[{"name":"范围","range":"(0,005 - 24,0) mg/l"}],"search_zh":"水、污水 酚指数 分光光度法 范围 PB-S-10 wydanie 2 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8047","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"酚指数"},{"_id":"6a5dc9bef1c10c8ce825e991","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,010 - 5,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 - 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,010 - 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,010 - 5,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,010 - 5,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,010 - 5,0) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e992","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 - 5 000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 - 5 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 - 5 000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280: 2002","norm_bases":["PN-ISO 9280: 2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (10 - 5 000) mg/l\nMetoda wagowa PN-ISO 9280: 2002 Woda, Scieki Stezenie siarczanow\nZakres (10 - 5 000) mg/l\nMetoda wagowa PN-ISO 9280: 2002","categories":["water"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280: 2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 - 5 000) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280: 2002","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e993","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki, Wody opadowe","test_object_en":"Water, Wastewater, Rainwater","methodology":"Indeks oleju mineralnego","methodology_en":"Mineral oil index","parameters":[{"name":"Zakres","range":"(0,20 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 – 50) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego\nZakres (0,20 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki, Wody opadowe Indeks oleju mineralnego\nZakres (0,20 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, Scieki, Wody opadowe Indeks oleju mineralnego\nZakres (0,20 – 50) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater, Rainwater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","parameters_zh":[{"name":"范围","range":"(0,20 – 50) mg/l"}],"search_zh":"矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"矿物油指数"},{"_id":"6a5dc9bef1c10c8ce825e994","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi, Ścieki, wody opadowe","test_object_en":"Water, water intended for human consumption, Wastewater, rainwater","methodology":"Stężenie ogólnego węgla organicznego (OWO)","methodology_en":"Total organic carbon concentration (TOC)","parameters":[{"name":"Zakres","range":"(0,5 – 6000) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,5 – 6000) mg/l"}],"technique":"Metoda spektrometrii w podczerwieni IR","techniques":["Metoda spektrometrii w podczerwieni IR"],"technique_en":"Infrared spectrometry IR","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego (OWO)\nZakres (0,5 – 6000) mg/l\nMetoda spektrometrii w podczerwieni IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi, Ścieki, wody opadowe Stężenie ogólnego węgla organicznego (OWO)\nZakres (0,5 – 6000) mg/l\nMetoda spektrometrii w podczerwieni IR PN-EN 1484:1999 Woda, woda do spozycia przez ludzi, Scieki, wody opadowe Stezenie ogolnego wegla organicznego (OWO)\nZakres (0,5 – 6000) mg/l\nMetoda spektrometrii w podczerwieni IR PN-EN 1484:1999","categories":["water"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption, Wastewater, rainwater Total organic carbon concentration (TOC) Infrared spectrometry IR Range PN-EN 1484:1999","parameters_zh":[{"name":"范围","range":"(0,5 – 6000) mg/l"}],"search_zh":"总有机碳浓度（TOC） 范围 PN-EN 1484:1999","methodology_zh":"总有机碳浓度（TOC）"},{"_id":"6a5dc9bef1c10c8ce825e995","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie substancji ekstrahujących się eterem naftowym","methodology_en":"Concentration of substances extractable with petroleum ether","parameters":[{"name":"Zakres","range":"(2,0 - 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 - 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym\nZakres (2,0 - 500) mg/l\nMetoda wagowa","reference":"PN-86C-04573/01","norm_bases":["PN-86C-04573/01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym\nZakres (2,0 - 500) mg/l\nMetoda wagowa PN-86C-04573/01 Scieki Stezenie substancji ekstrahujacych sie eterem naftowym\nZakres (2,0 - 500) mg/l\nMetoda wagowa PN-86C-04573/01","categories":["water"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Concentration of substances extractable with petroleum ether Gravimetric method Range PN-86C-04573/01","parameters_zh":[{"name":"范围","range":"(2,0 - 500) mg/l"}],"search_zh":"污水 石油醚可萃取物浓度 重量法 范围 PN-86C-04573/01","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物浓度"},{"_id":"6a5dc9bef1c10c8ce825e996","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie cyjanków wolnych","methodology_en":"Free cyanide concentration","parameters":[{"name":"Zakres","range":"(0,010 - 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 - 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie cyjanków wolnych\nZakres (0,010 - 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-S-16 wydanie 4 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8027","norm_bases":["PB-S-16 wydanie 4 z dnia 04.01.2021 r.","na podstawie testu kuwetowego HACH nr 8027"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie cyjanków wolnych\nZakres (0,010 - 1,0) mg/l\nMetoda spektrofotometryczna PB-S-16 wydanie 4 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8027 Scieki Stezenie cyjankow wolnych\nZakres (0,010 - 1,0) mg/l\nMetoda spektrofotometryczna PB-S-16 wydanie 4 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8027","categories":["water"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Free cyanide concentration Spectrophotometric method Range PB-S-16 wydanie 4 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8027","parameters_zh":[{"name":"范围","range":"(0,010 - 1,0) mg/l"}],"search_zh":"污水 游离氰化物浓度 分光光度法 范围 PB-S-16 wydanie 4 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8027","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"游离氰化物浓度"},{"_id":"6a5dc9bef1c10c8ce825e997","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie substancji powierzchniowo czynnych","methodology_en":"Concentration of surfactants","parameters":[{"name":"anionowych (surfaktanty anionowe)"},{"name":"Zakres","range":"(0,05 – 40) mg/l"}],"parameters_en":[{"name":"anionic (anionic surfactants)"},{"name":"Range","range":"(0,05 – 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie substancji powierzchniowo czynnych\nZakres:\nanionowych (surfaktanty anionowe)\nZakres (0,05 – 40) mg/l\nMetoda spektrofotometryczna","reference":"PB-S-39 wydanie 1 z dnia 02.08.2021 r. wg HACH LCK 332","norm_bases":["PB-S-39 wydanie 1 z dnia 02.08.2021 r. wg HACH LCK 332"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie substancji powierzchniowo czynnych\nZakres:\nanionowych (surfaktanty anionowe)\nZakres (0,05 – 40) mg/l\nMetoda spektrofotometryczna PB-S-39 wydanie 1 z dnia 02.08.2021 r. wg HACH LCK 332 Scieki Stezenie substancji powierzchniowo czynnych\nZakres:\nanionowych (surfaktanty anionowe)\nZakres (0,05 – 40) mg/l\nMetoda spektrofotometryczna PB-S-39 wydanie 1 z dnia 02.08.2021 r. wg HACH LCK 332","categories":["water"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Concentration of surfactants Spectrophotometric method anionic (anionic surfactants) Range PB-S-39 wydanie 1 z dnia 02.08.2021 r. wg HACH LCK 332","parameters_zh":[{"name":"anionowych (surfaktanty anionowe)"},{"name":"范围","range":"(0,05 – 40) mg/l"}],"search_zh":"污水 分光光度法 范围 PB-S-39 wydanie 1 z dnia 02.08.2021 r. wg HACH LCK 332","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bef1c10c8ce825e998","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Biochemiczne zapotrzebowania tlenu - BZT5","methodology_en":"Biochemical oxygen demand - BOD5","parameters":[{"name":"Zakres","range":"(3 - 3000) mg/l"}],"parameters_en":[{"name":"Range","range":"(3 - 3000) mg/l"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowania tlenu - BZT5\nZakres (3 - 3000) mg/l\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Biochemiczne zapotrzebowania tlenu - BZT5\nZakres (3 - 3000) mg/l\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki Biochemiczne zapotrzebowania tlenu - BZT5\nZakres (3 - 3000) mg/l\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Biochemical oxygen demand - BOD5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"范围","range":"(3 - 3000) mg/l"}],"search_zh":"污水 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水"},{"_id":"6a5dc9bef1c10c8ce825e999","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chromu (VI)","methodology_en":"Chromium(VI) concentration","parameters":[{"name":"Zakres","range":"(0,01 - 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,01 - 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chromu (VI)\nZakres (0,01 - 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604/08","norm_bases":["PN-77/C-04604/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chromu (VI)\nZakres (0,01 - 1,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08 Scieki Stezenie chromu (VI)\nZakres (0,01 - 1,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08","categories":["water"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chromium(VI) concentration Spectrophotometric method Range PN-77/C-04604/08","parameters_zh":[{"name":"范围","range":"(0,01 - 1,0) mg/l"}],"search_zh":"污水 六价铬浓度 分光光度法 范围 PN-77/C-04604/08","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"六价铬浓度"},{"_id":"6a5dc9bef1c10c8ce825e99a","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"chrom","range":"(0,050 – 2,0) mg/l"},{"name":"cynk","range":"(0,080 - 20,0) mg/l"},{"name":"glin","range":"(0,200 – 20,0) mg/l"},{"name":"kadm","range":"(0,050 - 2,0) mg/l"},{"name":"miedź","range":"(0,050 – 5,0) mg/l"},{"name":"nikiel","range":"(0,200 - 5,0) mg/l"},{"name":"ołów","range":"(0,200 - 5,0) mg/l"},{"name":"żelazo","range":"(0,200 – 50,0) mg/l"},{"name":"arsen","range":"(0,050 – 2,0) mg/l"}],"parameters_en":[{"name":"chromium","range":"(0,050 – 2,0) mg/l"},{"name":"zinc","range":"(0,080 - 20,0) mg/l"},{"name":"aluminium","range":"(0,200 – 20,0) mg/l"},{"name":"cadmium","range":"(0,050 - 2,0) mg/l"},{"name":"copper","range":"(0,050 – 5,0) mg/l"},{"name":"nickel","range":"(0,200 - 5,0) mg/l"},{"name":"lead","range":"(0,200 - 5,0) mg/l"},{"name":"iron","range":"(0,200 – 50,0) mg/l"},{"name":"arsenic","range":"(0,050 – 2,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nchrom (0,050 – 2,0) mg/l\ncynk (0,080 - 20,0) mg/l\nglin (0,200 – 20,0) mg/l\nkadm (0,050 - 2,0) mg/l\nmiedź (0,050 – 5,0) mg/l\nnikiel (0,200 - 5,0) mg/l\nołów (0,200 - 5,0) mg/l\nżelazo (0,200 – 50,0) mg/l\narsen (0,050 – 2,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie pierwiastków\nZakres:\nchrom (0,050 – 2,0) mg/l\ncynk (0,080 - 20,0) mg/l\nglin (0,200 – 20,0) mg/l\nkadm (0,050 - 2,0) mg/l\nmiedź (0,050 – 5,0) mg/l\nnikiel (0,200 - 5,0) mg/l\nołów (0,200 - 5,0) mg/l\nżelazo (0,200 – 50,0) mg/l\narsen (0,050 – 2,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie pierwiastkow\nZakres:\nchrom (0,050 – 2,0) mg/l\ncynk (0,080 - 20,0) mg/l\nglin (0,200 – 20,0) mg/l\nkadm (0,050 - 2,0) mg/l\nmiedz (0,050 – 5,0) mg/l\nnikiel (0,200 - 5,0) mg/l\nolow (0,200 - 5,0) mg/l\nzelazo (0,200 – 50,0) mg/l\narsen (0,050 – 2,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) chromium zinc aluminium cadmium copper nickel lead iron arsenic PN-EN ISO 11885:2009","methodology_zh":"元素浓度","parameters_zh":[{"name":"铬","range":"(0,050 – 2,0) mg/l"},{"name":"锌","range":"(0,080 - 20,0) mg/l"},{"name":"铝","range":"(0,200 – 20,0) mg/l"},{"name":"镉","range":"(0,050 - 2,0) mg/l"},{"name":"铜","range":"(0,050 – 5,0) mg/l"},{"name":"镍","range":"(0,200 - 5,0) mg/l"},{"name":"铅","range":"(0,200 - 5,0) mg/l"},{"name":"铁","range":"(0,200 – 50,0) mg/l"},{"name":"砷","range":"(0,050 – 2,0) mg/l"}],"search_zh":"污水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 铬 锌 铝 镉 铜 镍 铅 铁 砷 PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污水"},{"_id":"6a5dc9bef1c10c8ce825e99b","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura pobranej próbki ścieków"},{"name":"Zakres","range":"(0,5 - 50) °C"}],"parameters_en":[{"name":"Temperature of the collected wastewater sample"},{"name":"Range","range":"(0,5 - 50) °C"}],"technique":"Metoda manualna i automatyczna","techniques":["Metoda manualna i automatyczna"],"technique_en":"Manual and automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,5 - 50) °C\nMetoda manualna i automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura pobranej próbki ścieków\nZakres (0,5 - 50) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura pobranej probki sciekow\nZakres (0,5 - 50) °C\nMetoda manualna i automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Sampling for chemical and physical testing Manual and automatic method Temperature of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"所采废水样品的温度"},{"name":"范围","range":"(0,5 - 50) °C"}],"search_zh":"污水 化学与物理检测用样品采集 手工与自动法 所采废水样品的温度 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","test_object_zh":"污水","technique_zh":"手工与自动法"},{"_id":"6a5dc9bef1c10c8ce825e99c","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Chemiczne zapotrzebowanie tlenu","methodology_en":"Chemical oxygen demand","parameters":[{"name":"ChZT – Cr"},{"name":"Zakres","range":"(10,0 - 15 000) mg/l O2"}],"parameters_en":[{"name":"COD – Cr"},{"name":"Range","range":"(10,0 - 15 000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT – Cr\nZakres (10,0 - 15 000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT – Cr\nZakres (10,0 - 15 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT – Cr\nZakres (10,0 - 15 000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chemical oxygen demand Spectrophotometric method COD – Cr Range PN-ISO 15705:2005","parameters_zh":[{"name":"ChZT – Cr"},{"name":"范围","range":"(10,0 - 15 000) mg/l O2"}],"search_zh":"水、污水 化学需氧量（COD） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a5dc9bef1c10c8ce825e99d","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowania tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3 - 2000) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3 - 2000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowania tlenu\nZakres:\nBZT5\nZakres (3 - 2000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowania tlenu\nZakres:\nBZT5\nZakres (3 - 2000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Woda, Scieki Biochemiczne zapotrzebowania tlenu\nZakres:\nBZT5\nZakres (3 - 2000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019-12","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3 - 2000) mg/l O2"}],"search_zh":"水、污水 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e99e","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Biochemiczne zapotrzebowania tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,5 - 6,0) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,5 - 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowania tlenu\nZakres:\nBZT5\nZakres (0,5 - 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowania tlenu\nZakres:\nBZT5\nZakres (0,5 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowania tlenu\nZakres:\nBZT5\nZakres (0,5 - 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,5 - 6,0) mg/l O2"}],"search_zh":"水、污水 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e99f","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(1,0 - 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 - 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (1,0 - 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (1,0 - 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (1,0 - 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 - 250) mg/l"}],"search_zh":"水、污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e9a0","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,10 - 40) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 - 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,10 - 40) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu amonowego\nZakres (0,10 - 40) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, Scieki Stezenie azotu amonowego\nZakres (0,10 - 40) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 40) mg/l"}],"search_zh":"水、污水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e9a1","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,10 - 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 - 50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,10 - 50) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotanowego\nZakres (0,10 - 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, Scieki Stezenie azotu azotanowego\nZakres (0,10 - 50) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 50) mg/l"}],"search_zh":"水、污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e9a2","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,080 - 40) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,080 - 40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,080 - 40) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie fosforu ogólnego\nZakres (0,080 - 40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie fosforu ogolnego\nZakres (0,080 - 40) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010","categories":["water"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,080 - 40) mg/l"}],"search_zh":"水、污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 (pkt 7) +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e9a3","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,080 - 40) mg/l P-PO4"}],"parameters_en":[{"name":"Range","range":"(0,080 - 40) mg/l P-PO4"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,080 - 40) mg/l P-PO4\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie ortofosforanów\nZakres (0,080 - 40) mg/l P-PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010 Woda, Scieki Stezenie ortofosforanow\nZakres (0,080 - 40) mg/l P-PO4\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010","categories":["water"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,080 - 40) mg/l P-PO4"}],"search_zh":"水、污水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 (pkt 4) +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9bef1c10c8ce825e9a4","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 - 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 - 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 - 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 - 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 - 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 - 2000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e9a5","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"(3,0 - 12,0)"}],"parameters_en":[{"name":"Range","range":"(3,0 - 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres (3,0 - 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki pH\nZakres (3,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Scieki pH\nZakres (3,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(3,0 - 12,0)"}],"search_zh":"水、污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e9a6","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,284 - 25) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,284 - 25) mg/l"}],"technique":"Metoda spektrometryczna","techniques":["Metoda spektrometryczna"],"technique_en":"Spectrometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,284 - 25) mg/l\nMetoda spektrometryczna","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (0,284 - 25) mg/l\nMetoda spektrometryczna PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (0,284 - 25) mg/l\nMetoda spektrometryczna PN-EN 25663:2001","categories":["water"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Kjeldahl nitrogen concentration Spectrometric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,284 - 25) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 光谱法 范围 PN-EN 25663:2001","test_object_zh":"水、污水","technique_zh":"光谱法"},{"_id":"6a5dc9bef1c10c8ce825e9a7","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(6,5 - 450) mg/l"}],"parameters_en":[{"name":"Range","range":"(6,5 - 450) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (6,5 - 450) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu Kjeldahla\nZakres (6,5 - 450) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, Scieki Stezenie azotu Kjeldahla\nZakres (6,5 - 450) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(6,5 - 450) mg/l"}],"search_zh":"水、污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e9a8","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73C-04576/14","norm_bases":["PN-73C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu ogólnego (z obliczeń) PN-73C-04576/14 Woda, Scieki Stezenie azotu ogolnego (z obliczen) PN-73C-04576/14","categories":["water"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Total nitrogen concentration (calculated) PN-73C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"水、污水 总氮浓度（计算值） PN-73C-04576/14","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e9a9","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(6,4 - 3500) mg/l"}],"parameters_en":[{"name":"Range","range":"(6,4 - 3500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (6,4 - 3500) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie chlorków\nZakres (6,4 - 3500) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Scieki Stezenie chlorkow\nZakres (6,4 - 3500) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":101,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(6,4 - 3500) mg/l"}],"search_zh":"水、污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e9aa","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,005 - 22,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,005 - 22,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,005 - 22,0) mg/l\nMetoda spektrofotometryczna","reference":"PB-S-10 wydanie 2 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8047","norm_bases":["PB-S-10 wydanie 2 z dnia 04.01.2021 r.","na podstawie testu kuwetowego HACH nr 8047"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Indeks fenolowy\nZakres (0,005 - 22,0) mg/l\nMetoda spektrofotometryczna PB-S-10 wydanie 2 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8047 Woda, Scieki Indeks fenolowy\nZakres (0,005 - 22,0) mg/l\nMetoda spektrofotometryczna PB-S-10 wydanie 2 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8047","categories":["water"],"row_index":102,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Phenol index Spectrophotometric method Range PB-S-10 wydanie 2 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8047","parameters_zh":[{"name":"范围","range":"(0,005 - 22,0) mg/l"}],"search_zh":"水、污水 酚指数 分光光度法 范围 PB-S-10 wydanie 2 z dnia 04.01.2021 r. | na podstawie testu kuwetowego HACH nr 8047","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"酚指数"},{"_id":"6a5dc9bef1c10c8ce825e9ab","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,025 - 5,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,025 - 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,025 - 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie azotu azotynowego\nZakres (0,025 - 5,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, Scieki Stezenie azotu azotynowego\nZakres (0,025 - 5,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":103,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,025 - 5,0) mg/l"}],"search_zh":"水、污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e9ac","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 - 5 000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 - 5 000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 - 5 000) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie siarczanów\nZakres (10 - 5 000) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, Scieki Stezenie siarczanow\nZakres (10 - 5 000) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":104,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 - 5 000) mg/l"}],"search_zh":"水、污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e9ad","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie substancji powierzchniowo czynnych anionowych (surfaktanty anionowe)","methodology_en":"Concentration of anionic surfactants (anionic surfactants)","parameters":[{"name":"Zakres","range":"(0,10 – 20) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie substancji powierzchniowo czynnych anionowych (surfaktanty anionowe)\nZakres (0,10 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PB-S-49 wydanie 2 z dnia 02.09.2022 r. wg HACH LCK 332","norm_bases":["PB-S-49 wydanie 2 z dnia 02.09.2022 r. wg HACH LCK 332"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie substancji powierzchniowo czynnych anionowych (surfaktanty anionowe)\nZakres (0,10 – 20) mg/l\nMetoda spektrofotometryczna PB-S-49 wydanie 2 z dnia 02.09.2022 r. wg HACH LCK 332 Woda, Scieki Stezenie substancji powierzchniowo czynnych anionowych (surfaktanty anionowe)\nZakres (0,10 – 20) mg/l\nMetoda spektrofotometryczna PB-S-49 wydanie 2 z dnia 02.09.2022 r. wg HACH LCK 332","categories":["water"],"row_index":105,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Concentration of anionic surfactants (anionic surfactants) Spectrophotometric method Range PB-S-49 wydanie 2 z dnia 02.09.2022 r. wg HACH LCK 332","parameters_zh":[{"name":"范围","range":"(0,10 – 20) mg/l"}],"search_zh":"水、污水 分光光度法 范围 PB-S-49 wydanie 2 z dnia 02.09.2022 r. wg HACH LCK 332","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a5dc9bef1c10c8ce825e9ae","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Woda, Ścieki","test_object_en":"Water, Wastewater","methodology":"Stężenie cyjanków wolnych","methodology_en":"Free cyanide concentration","parameters":[{"name":"Zakres","range":"(0,010 – 2,5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 – 2,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie cyjanków wolnych\nZakres (0,010 – 2,5) mg/l\nMetoda spektrofotometryczna","reference":"PB-S-52 wydanie 1 z dnia 01.06.2024 r. wg HACH LCK 315","norm_bases":["PB-S-52 wydanie 1 z dnia 01.06.2024 r. wg HACH LCK 315"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, Ścieki Stężenie cyjanków wolnych\nZakres (0,010 – 2,5) mg/l\nMetoda spektrofotometryczna PB-S-52 wydanie 1 z dnia 01.06.2024 r. wg HACH LCK 315 Woda, Scieki Stezenie cyjankow wolnych\nZakres (0,010 – 2,5) mg/l\nMetoda spektrofotometryczna PB-S-52 wydanie 1 z dnia 01.06.2024 r. wg HACH LCK 315","categories":["water"],"row_index":106,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, Wastewater Free cyanide concentration Spectrophotometric method Range PB-S-52 wydanie 1 z dnia 01.06.2024 r. wg HACH LCK 315","parameters_zh":[{"name":"范围","range":"(0,010 – 2,5) mg/l"}],"search_zh":"水、污水 游离氰化物浓度 分光光度法 范围 PB-S-52 wydanie 1 z dnia 01.06.2024 r. wg HACH LCK 315","technique_zh":"分光光度法","test_object_zh":"水、污水","methodology_zh":"游离氰化物浓度"},{"_id":"6a5dc9bef1c10c8ce825e9af","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Osady ściekowe, Odpady, kod: 19 08 05","test_object_en":"Sewage sludge, Waste, code: 19 08 05","methodology":"Sucha pozostałość i zawartość wody","methodology_en":"Dry residue and water content","parameters":[{"name":"Zakres","range":"(0,5 - 100) %"}],"parameters_en":[{"name":"Range","range":"(0,5 - 100) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość i zawartość wody\nZakres (0,5 - 100) %\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Odpady, kod: 19 08 05 Sucha pozostałość i zawartość wody\nZakres (0,5 - 100) %\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe, Odpady, kod: 19 08 05 Sucha pozostalosc i zawartosc wody\nZakres (0,5 - 100) %\nMetoda wagowa PN-EN 12880:2004","categories":["water","environment"],"row_index":107,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Waste, code: 19 08 05 Dry residue and water content Gravimetric method Range PN-EN 12880:2004","parameters_zh":[{"name":"范围","range":"(0,5 - 100) %"}],"search_zh":"污水污泥、废物，代码：19 08 05 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污水污泥、废物，代码：19 08 05"},{"_id":"6a5dc9bef1c10c8ce825e9b0","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Osady ściekowe, Odpady, kod: 19 08 05","test_object_en":"Sewage sludge, Waste, code: 19 08 05","methodology":"Straty po prażeniu i pozostałość po prażeniu","methodology_en":"Loss on ignition and residue on ignition","parameters":[{"name":"Zakres","range":"(0,5 - 100) %"}],"parameters_en":[{"name":"Range","range":"(0,5 - 100) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty po prażeniu i pozostałość po prażeniu\nZakres (0,5 - 100) %\nMetoda wagowa","reference":"PN-EN 12879:2004","norm_bases":["PN-EN 12879:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Odpady, kod: 19 08 05 Straty po prażeniu i pozostałość po prażeniu\nZakres (0,5 - 100) %\nMetoda wagowa PN-EN 12879:2004 Osady sciekowe, Odpady, kod: 19 08 05 Straty po prazeniu i pozostalosc po prazeniu\nZakres (0,5 - 100) %\nMetoda wagowa PN-EN 12879:2004","categories":["water","environment"],"row_index":108,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Waste, code: 19 08 05 Loss on ignition and residue on ignition Gravimetric method Range PN-EN 12879:2004","parameters_zh":[{"name":"范围","range":"(0,5 - 100) %"}],"search_zh":"污水污泥、废物，代码：19 08 05 重量法 范围 PN-EN 12879:2004","technique_zh":"重量法","test_object_zh":"污水污泥、废物，代码：19 08 05"},{"_id":"6a5dc9bef1c10c8ce825e9b1","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Osady ściekowe, Odpady, kod: 19 08 05","test_object_en":"Sewage sludge, Waste, code: 19 08 05","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"(3,0 - 13,0)"}],"parameters_en":[{"name":"Range","range":"(3,0 - 13,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres (3,0 - 13,0)\nMetoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Odpady, kod: 19 08 05 pH\nZakres (3,0 - 13,0)\nMetoda potencjometryczna PN-EN 12176:2004 Osady sciekowe, Odpady, kod: 19 08 05 pH\nZakres (3,0 - 13,0)\nMetoda potencjometryczna PN-EN 12176:2004","categories":["water","environment"],"row_index":109,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Waste, code: 19 08 05 pH Potentiometric method Range PN-EN 12176:2004","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(3,0 - 13,0)"}],"search_zh":"污水污泥、废物，代码：19 08 05 pH 值 电位法 范围 PN-EN 12176:2004","technique_zh":"电位法","test_object_zh":"污水污泥、废物，代码：19 08 05"},{"_id":"6a5dc9bef1c10c8ce825e9b2","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Osady ściekowe, Odpady, kod: 19 08 05","test_object_en":"Sewage sludge, Waste, code: 19 08 05","methodology":"Zawartość azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen content","parameters":[{"name":"Zakres","range":"(0,14 - 10) %"}],"parameters_en":[{"name":"Range","range":"(0,14 - 10) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,14 - 10) %\nMetoda miareczkowa","reference":"PB-S-41 wydanie 2 z dnia 04.01.2021 r.","norm_bases":["PB-S-41 wydanie 2 z dnia 04.01.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Odpady, kod: 19 08 05 Zawartość azotu Kjeldahla\nZakres (0,14 - 10) %\nMetoda miareczkowa PB-S-41 wydanie 2 z dnia 04.01.2021 r. Osady sciekowe, Odpady, kod: 19 08 05 Zawartosc azotu Kjeldahla\nZakres (0,14 - 10) %\nMetoda miareczkowa PB-S-41 wydanie 2 z dnia 04.01.2021 r.","categories":["water","environment"],"row_index":110,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Waste, code: 19 08 05 Kjeldahl nitrogen content Titrimetric method Range PB-S-41 wydanie 2 z dnia 04.01.2021 r.","parameters_zh":[{"name":"范围","range":"(0,14 - 10) %"}],"search_zh":"污水污泥、废物，代码：19 08 05 凯氏氮含量 滴定法 范围 PB-S-41 wydanie 2 z dnia 04.01.2021 r.","technique_zh":"滴定法","methodology_zh":"凯氏氮含量","test_object_zh":"污水污泥、废物，代码：19 08 05"},{"_id":"6a5dc9bef1c10c8ce825e9b3","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Osady ściekowe, Odpady, kod: 19 08 05","test_object_en":"Sewage sludge, Waste, code: 19 08 05","methodology":"Zawartość fosforu ogólnego","methodology_en":"Total phosphorus content","parameters":[{"name":"Zakres","range":"(0,05 - 10) %"}],"parameters_en":[{"name":"Range","range":"(0,05 - 10) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,05 - 10) %\nMetoda spektrofotometryczna","reference":"PB-S-47 wydanie 2 z dnia 04.01.2021 r.","norm_bases":["PB-S-47 wydanie 2 z dnia 04.01.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Odpady, kod: 19 08 05 Zawartość fosforu ogólnego\nZakres (0,05 - 10) %\nMetoda spektrofotometryczna PB-S-47 wydanie 2 z dnia 04.01.2021 r. Osady sciekowe, Odpady, kod: 19 08 05 Zawartosc fosforu ogolnego\nZakres (0,05 - 10) %\nMetoda spektrofotometryczna PB-S-47 wydanie 2 z dnia 04.01.2021 r.","categories":["water","environment"],"row_index":111,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Waste, code: 19 08 05 Total phosphorus content Spectrophotometric method Range PB-S-47 wydanie 2 z dnia 04.01.2021 r.","parameters_zh":[{"name":"范围","range":"(0,05 - 10) %"}],"search_zh":"污水污泥、废物，代码：19 08 05 总磷含量 分光光度法 范围 PB-S-47 wydanie 2 z dnia 04.01.2021 r.","technique_zh":"分光光度法","methodology_zh":"总磷含量","test_object_zh":"污水污泥、废物，代码：19 08 05"},{"_id":"6a5dc9bef1c10c8ce825e9b4","lab_id":"69ad52a3de79e566650fb3ea","country":"PL","accr_number":"AB 776","accr_body":"PCA","test_object":"Osady ściekowe, Odpady, kod: 19 08 05","test_object_en":"Sewage sludge, Waste, code: 19 08 05","methodology":"Pobieranie próbek do badań chemicznych, biologicznych i fizycznych","methodology_en":"Sampling for chemical, biological and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych, biologicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.2, 6.3.3, 6.3.4, 6.3.5, 6.3.6, 6.3.7, 6.3.9, 6.3.10","norm_bases":["PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.2, 6.3.3, 6.3.4, 6.3.5, 6.3.6, 6.3.7, 6.3.9, 6.3.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, Odpady, kod: 19 08 05 Pobieranie próbek do badań chemicznych, biologicznych i fizycznych PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.2, 6.3.3, 6.3.4, 6.3.5, 6.3.6, 6.3.7, 6.3.9, 6.3.10 Osady sciekowe, Odpady, kod: 19 08 05 Pobieranie probek do badan chemicznych, biologicznych i fizycznych PN-EN ISO 5667-13:2011 z wylaczeniem pkt. 6.3.2, 6.3.3, 6.3.4, 6.3.5, 6.3.6, 6.3.7, 6.3.9, 6.3.10","categories":["water","environment"],"row_index":112,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, Waste, code: 19 08 05 Sampling for chemical, biological and physical testing PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.2, 6.3.3, 6.3.4, 6.3.5, 6.3.6, 6.3.7, 6.3.9, 6.3.10","search_zh":"污水污泥、废物，代码：19 08 05 PN-EN ISO 5667-13:2011 z wyłączeniem pkt. 6.3.2, 6.3.3, 6.3.4, 6.3.5, 6.3.6, 6.3.7, 6.3.9, 6.3.10","test_object_zh":"污水污泥、废物，代码：19 08 05"}],"has_pdf":true}