🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL
Water & wastewaterMicrobiology
POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 766 (Aleksandrów Kujawski, Poland). Its accreditation scope covers 22 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Swimming pool water, Water intended for human consumption, Water (including swimming pool water), water intended for human con…. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 766
- Methods in scope: 22
- Types of test objects: 5
- Techniques used: 7
- City: Aleksandrów Kujawski, Poland
- Accreditation number
- AB 766
- Accreditation body
- PCA
- Address
- W ALEKSANDROWIE KUJAWSKIM, ul. Słowackiego 8a, 87-700 Aleksandrów Kujawski
- City
- Aleksandrów Kujawski, Poland
What this laboratory tests (5)
- Water, water intended for human consumption — 9 methods
- Swimming pool water — 5 methods
- Water intended for human consumption — 4 methods
- Water (including swimming pool water), water intended for human consumption — 3 methods
- Domestic hot water — 1 method
Analytical techniques used (7)
- Membrane filtration method — 8 methods
- Spectrophotometric method — 6 methods
- Titrimetric method — 3 methods
- Plate method (pour plate) — 2 methods
- Conductometric method — 1 method
- Nephelometric method — 1 method
- Potentiometric method — 1 method
Accreditation scope — test methods (22)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water, water intended for human consumption | Iron concentration Range (30 - 5000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001 p.7.1 | PN-ISO 6332:2001/Ap1:2016-06 | |
| 2 | Water, water intended for human consumption | Nitrite concentration Range (0,02 - 0,82) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 3 | Water, water intended for human consumption | Manganese concentration Range (30 - 3000) μg/l |
Spectrophotometric method | PN-92/C-04590/03 | |
| 4 | Water, water intended for human consumption | Ammonium ion concentration Range (0,34 - 2,57) mg/l |
Spectrophotometric method | PN-C-04576-04:1994 | |
| 5 | Water, water intended for human consumption | Colour Range (2 - 140) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06 | |
| 6 | Water, water intended for human consumption | pH Range 2,0 - 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 7 | Water, water intended for human consumption | Chloride concentration Range (5 - 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 8 | Water, water intended for human consumption | Calcium and magnesium concentration (total hardness) Range (5 - 500) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 9 | Water, water intended for human consumption | Electrical conductivity Range 150 μS/cm - 12,9 mS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 10 | Water (including swimming pool water), water intended for human consumption | Nitrate concentration Range (0,27 - 222) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 11 | Water (including swimming pool water), water intended for human consumption | Permanganate index Range (1 - 10) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 12 | Water (including swimming pool water), water intended for human consumption | Turbidity Range (0,1 – 40) NTU |
Nephelometric method | PN-EN ISO 7027-1: 2016-09 | |
| 13 | Water intended for human consumption | Total viable count at 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 14 | Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 15 | Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 | |
| 16 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 | |
| 17 | Swimming pool water | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 | |
| 18 | Swimming pool water | Total viable count at 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 19 | Swimming pool water | Coagulase-positive staphylococci count | Membrane filtration method | Metodyka PZH ZHK: 2007 „Badania w kierunku wykrywania i izolacji gronkowców koagulazo-dodatnich z środowiska wodnego” | |
| 20 | Swimming pool water | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 21 | Swimming pool water | Count of bacteria of the genus Legionella Range od 1 jtk/100 ml from 1 CFU/l Matrix A Procedure 5 (BCYE medium) Procedure 7 (GVPC medium) |
Membrane filtration method | PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12 | |
| 22 | Domestic hot water | Count of bacteria of the genus Legionella Range od 1 jtk/100 ml from 1 CFU/l Matrix A Procedure 5 (BCYE medium) Procedure 7 (GVPC medium) |
Membrane filtration method | PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12 | |
Reference standards (22)
Metodyka PZH ZHK: 2007 „Badania w kierunku wykrywania i izolacji gronkowców koagulazo-dodatnich z środowiska wodnego”
PN-82/C-04576/08
PN-92/C-04590/03
PN-C-04576-04:1994
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08
PN-EN ISO 11731:2017-08/Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1: 2016-09
PN-EN ISO 7887:2012 Metoda C
PN-EN ISO 7887:2012/Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/A1:2017-04
PN-ISO 6059:1999
PN-ISO 6332:2001 p.7.1
PN-ISO 6332:2001/Ap1:2016-06
PN-ISO 9297:1994