{"lab":{"_id":"69ad52a3de79e566650fb3da","accr_number":"AB 766","country":"PL","accr_body":"PCA","address":"W ALEKSANDROWIE KUJAWSKIM, ul. Słowackiego 8a, 87-700 Aleksandrów Kujawski","categories":["water","microbiology"],"city":"Aleksandrów Kujawski","imported_at":"2026-03-08T10:42:43.265Z","methods_count":22,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_766.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w aleksandrowie kujawskim, ul. słowackiego 8a, 87-700 aleksandrów kujawski other water pharma electronics automotive microbiology environment construction food","status":"active","updated_at":"2026-03-08T14:51:39.278Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-23T00:31:40.666Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20766,podmiot.html","fields_of_testing":[{"codes":"C/28, C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"K/28, K/29","pl":"Badania mikrobiologiczne wody, wody do spożycia przez ludzi","en":"Microbiological tests of water, drinking water"},{"codes":"","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"}],"issue":{"no":"18","date":"21.08.2026"},"parse_date":"2026-08-23T00:31:40.666Z","parse_source":"agent-claude-code","map_coord":[52.874898,18.696429],"map_geo":"nominatim-street","has_en":true,"lab_locations":[{"name":"Oddział Laboratoryjny","address":"ul. Słowackiego 8a, 87-700 Aleksandrów Kujawski","city":"Aleksandrów Kujawski","postal":"87-700"},{"name":"Laboratorium Badania Środowiska Komunalnego","address":"ul. Słowackiego 8a, 87-700 Aleksandrów Kujawski","city":"Aleksandrów Kujawski","postal":"87-700"},{"name":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/22/aa23a2a2a962ed25702cd66ab3395a8f/AB%20766.pdf","category_counts":{"water":22,"microbiology":5,"construction":1,"environment":1},"category_scores":{"water":16.69,"microbiology":0.86,"construction":0.03,"environment":0.03},"has_zh":true},"methods":[{"_id":"6a8a3f6cfbf98dd0af9b52ad","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(30 - 5000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (30 - 5000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 p.7.1 | PN-ISO 6332:2001/Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 p.7.1","PN-ISO 6332:2001/Ap1:2016-06"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza\nZakres (30 - 5000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 p.7.1 | PN-ISO 6332:2001/Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza\nZakres (30 - 5000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 p.7.1 | PN-ISO 6332:2001/Ap1:2016-06","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(30 - 5000) μg/l"}],"search_zh":"水、生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001 p.7.1 | PN-ISO 6332:2001/Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52ae","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,02 - 0,82) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,02 - 0,82) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,02 - 0,82) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,02 - 0,82) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,02 - 0,82) mg/l"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52af","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(30 - 3000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (30 - 3000) μg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (30 - 3000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (30 - 3000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(30 - 3000) μg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52b0","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie jonów amonowych","parameters":[{"name":"Zakres","range":"(0,34 - 2,57) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonów amonowych\nZakres (0,34 - 2,57) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-04:1994","norm_bases":["PN-C-04576-04:1994"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonów amonowych\nZakres (0,34 - 2,57) mg/l\nMetoda spektrofotometryczna PN-C-04576-04:1994 Woda, woda do spozycia przez ludzi Stezenie jonow amonowych\nZakres (0,34 - 2,57) mg/l\nMetoda spektrofotometryczna PN-C-04576-04:1994","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,34 - 2,57) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PN-C-04576-04:1994","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"铵离子浓度"},{"_id":"6a8a3f6cfbf98dd0af9b52b1","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2 - 140) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2 - 140) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda C","PN-EN ISO 7887:2012/Ap1:2015-06"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (2 - 140) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06 Woda, woda do spozycia przez ludzi Barwa\nZakres (2 - 140) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2 - 140) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 Metoda C | PN-EN ISO 7887:2012/Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52b2","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 - 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 - 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi pH\nZakres 2,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi pH\nZakres 2,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 - 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52b3","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 - 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 - 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorków\nZakres (5 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 - 400) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52b4","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Stężenie wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 - 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia i magnezu (twardość ogólna)\nZakres (5 - 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia i magnezu (twardość ogólna)\nZakres (5 - 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Stezenie wapnia i magnezu (twardosc ogolna)\nZakres (5 - 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(5 - 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52b5","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"150 μS/cm - 12,9 mS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres 150 μS/cm - 12,9 mS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres 150 μS/cm - 12,9 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres 150 μS/cm - 12,9 mS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"150 μS/cm - 12,9 mS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52b6","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,27 - 222) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,27 - 222) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,27 - 222) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,27 - 222) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,27 - 222) mg/l"}],"search_zh":"水（含游泳池水）、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52b7","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(1 - 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (1 - 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (1 - 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (1 - 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(1 - 10) mg/l O2"}],"search_zh":"水（含游泳池水）、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52b8","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,1 – 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,1 – 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1: 2016-09","norm_bases":["PN-EN ISO 7027-1: 2016-09"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Mętność\nZakres (0,1 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1: 2016-09 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Metnosc\nZakres (0,1 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1: 2016-09","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,1 – 40) NTU"}],"search_zh":"水（含游泳池水）、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1: 2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52b9","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"22°C 微生物总数","search_zh":"生活饮用水 22°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52ba","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52bb","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52bc","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a8a3f6cfbf98dd0af9b52bd","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a8a3f6cfbf98dd0af9b52be","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Ogólna liczba mikroorganizmów w temp. 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w temp. 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"游泳池水 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"游泳池水","methodology_zh":"36°C 微生物总数"},{"_id":"6a8a3f6cfbf98dd0af9b52bf","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba gronkowców koagulazo-dodatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej","reference":"Metodyka PZH ZHK: 2007 „Badania w kierunku wykrywania i izolacji gronkowców koagulazo-dodatnich z środowiska wodnego”","norm_bases":["Metodyka PZH ZHK: 2007 „Badania w kierunku wykrywania i izolacji gronkowców koagulazo-dodatnich z środowiska wodnego”"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej Metodyka PZH ZHK: 2007 „Badania w kierunku wykrywania i izolacji gronkowców koagulazo-dodatnich z środowiska wodnego” Woda na plywalniach Liczba gronkowcow koagulazo-dodatnich\nMetoda filtracji membranowej Metodyka PZH ZHK: 2007 „Badania w kierunku wykrywania i izolacji gronkowcow koagulazo-dodatnich z srodowiska wodnego”","categories":["water","environment","construction"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"游泳池水 凝固酶阳性葡萄球菌计数 膜过滤法 Metodyka PZH ZHK: 2007 „Badania w kierunku wykrywania i izolacji gronkowców koagulazo-dodatnich z środowiska wodnego”","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a8a3f6cfbf98dd0af9b52c0","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a8a3f6cfbf98dd0af9b52c1","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba bakterii z rodzaju Legionella","parameters":[{"name":"Zakres","range":"od 1 jtk/100 ml"},{"name":"od 1 jtk/l Matryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella\nZakres:\nZakres od 1 jtk/100 ml\nod 1 jtk/l Matryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08/Ap1:2019-12"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella\nZakres:\nZakres od 1 jtk/100 ml\nod 1 jtk/l Matryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12 Woda na plywalniach Liczba bakterii z rodzaju Legionella\nZakres:\nZakres od 1 jtk/100 ml\nod 1 jtk/l Matryca A Procedura 5 (pozywka BCYE) Procedura 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","categories":["microbiology","water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"od 1 jtk/100 ml"},{"name":"od 1 jtk/l Matryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC)"}],"search_zh":"游泳池水 军团菌属细菌计数 膜过滤法 范围 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"军团菌属细菌计数"},{"_id":"6a8a3f6cfbf98dd0af9b52c2","lab_id":"69ad52a3de79e566650fb3da","country":"PL","accr_number":"AB 766","accr_body":"PCA","test_object":"Ciepła woda użytkowa","methodology":"Liczba bakterii z rodzaju Legionella","parameters":[{"name":"Zakres","range":"od 1 jtk/100 ml"},{"name":"od 1 jtk/l Matryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella\nZakres:\nZakres od 1 jtk/100 ml\nod 1 jtk/l Matryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08/Ap1:2019-12"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badania Środowiska Komunalnego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ciepła woda użytkowa Liczba bakterii z rodzaju Legionella\nZakres:\nZakres od 1 jtk/100 ml\nod 1 jtk/l Matryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12 Ciepla woda uzytkowa Liczba bakterii z rodzaju Legionella\nZakres:\nZakres od 1 jtk/100 ml\nod 1 jtk/l Matryca A Procedura 5 (pozywka BCYE) Procedura 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","categories":["microbiology","water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"od 1 jtk/100 ml"},{"name":"od 1 jtk/l Matryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC)"}],"search_zh":"军团菌属细菌计数 膜过滤法 范围 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/Ap1:2019-12","technique_zh":"膜过滤法","methodology_zh":"军团菌属细菌计数"}],"has_pdf":true}