🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL

PCA AB 764 • Inowrocław, Poland • 25 methods

Water & wastewaterMicrobiology

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 764 (Inowrocław, Poland). Its accreditation scope covers 25 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Swimming pool water, Bathing water. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 764
  • Methods in scope: 25
  • Types of test objects: 3
  • Techniques used: 9
  • City: Inowrocław, Poland
Accreditation number
AB 764
Accreditation body
PCA
Address
W INOWROCŁAWIU, Plac Klasztorny 1b, 88-100 Inowrocław
City
Inowrocław, Poland

What this laboratory tests (3)

Analytical techniques used (9)

Accreditation scope — test methods (25)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Manganese concentration
Range (30 – 3000) μg/l
Spectrophotometric method PN-92/C-04590/02
2 Water intended for human consumption Nitrate concentration
Range (0,18 – 200) mg/l
Spectrophotometric method PN-82/C-04576/08
3 Water intended for human consumption Nitrite concentration
Range (0,04 – 0,80) mg/l
Spectrophotometric method PN-EN 26777:1999
4 Water intended for human consumption Iron concentration
Range (20 – 5000) μg/l
Spectrophotometric method PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06
5 Water intended for human consumption Ammonium ion concentration
Range (0,258 – 2,58) mg/l
Spectrophotometric method PN-C-04576-04:1994
6 Water intended for human consumption pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
7 Water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda D
8 Water intended for human consumption Electrical conductivity
Range (100 – 4900) μS/cm
Conductometric method PN-EN 27888:1999
9 Water intended for human consumption Chloride concentration
Range (5 - 400) mg/l
Titrimetric method PN-ISO 9297:1994
10 Water intended for human consumption Permanganate index
Range (1,0 -10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
11 Water intended for human consumption Turbidity
Range (0,10 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016
12 Swimming pool water Nitrate concentration
Range (0,18 – 200) mg/l
Spectrophotometric method PN-82/C-04576/08
13 Swimming pool water pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
14 Swimming pool water Permanganate index
Range (1,0 -10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
15 Swimming pool water Turbidity
Range (0,10 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016
16 Water intended for human consumption Coliform bacteria count Membrane filtration method PN -EN ISO 9308-1:2014-12 | PN -EN ISO 9308-1:2014-12/A1:2017-04
17 Water intended for human consumption Escherichia coli count Membrane filtration method PN -EN ISO 9308-1:2014-12 | PN -EN ISO 9308-1:2014-12/A1:2017-04
18 Water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
19 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
20 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04
21 Swimming pool water Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
22 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PB-04/LHK Wydanie VI z dnia 22.03.2022 r.
23 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
24 Bathing water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
25 Bathing water Most probable number, Escherichia coli Miniaturized method PN-EN ISO 9308-3:2002

Reference standards (21)

PB-04/LHK Wydanie VI z dnia 22.03.2022 r.
PN -EN ISO 9308-1:2014-12
PN -EN ISO 9308-1:2014-12/A1:2017-04
PN-82/C-04576/08
PN-92/C-04590/02
PN-C-04576-04:1994
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016
PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/A1:2017-04
PN-EN ISO 9308-3:2002
PN-ISO 6332:2001
PN-ISO 6332:2001/Ap1:2016-06
PN-ISO 9297:1994