🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL
Water & wastewaterMicrobiology
POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 764 (Inowrocław, Poland). Its accreditation scope covers 25 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Swimming pool water, Bathing water. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 764
- Methods in scope: 25
- Types of test objects: 3
- Techniques used: 9
- City: Inowrocław, Poland
- Accreditation number
- AB 764
- Accreditation body
- PCA
- Address
- W INOWROCŁAWIU, Plac Klasztorny 1b, 88-100 Inowrocław
- City
- Inowrocław, Poland
What this laboratory tests (3)
- Water intended for human consumption — 15 methods
- Swimming pool water — 8 methods
- Bathing water — 2 methods
Analytical techniques used (9)
- Membrane filtration method — 7 methods
- Spectrophotometric method — 6 methods
- Titrimetric method — 3 methods
- Nephelometric method — 2 methods
- Plate method (pour plate) — 2 methods
- Potentiometric method — 2 methods
- Conductometric method — 1 method
- Miniaturized method — 1 method
- Visual method — 1 method
Accreditation scope — test methods (25)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Manganese concentration Range (30 – 3000) μg/l |
Spectrophotometric method | PN-92/C-04590/02 | |
| 2 | Water intended for human consumption | Nitrate concentration Range (0,18 – 200) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 3 | Water intended for human consumption | Nitrite concentration Range (0,04 – 0,80) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 4 | Water intended for human consumption | Iron concentration Range (20 – 5000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06 | |
| 5 | Water intended for human consumption | Ammonium ion concentration Range (0,258 – 2,58) mg/l |
Spectrophotometric method | PN-C-04576-04:1994 | |
| 6 | Water intended for human consumption | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 7 | Water intended for human consumption | Colour Range (5 – 70) mg/l Pt |
Visual method | PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda D | |
| 8 | Water intended for human consumption | Electrical conductivity Range (100 – 4900) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 9 | Water intended for human consumption | Chloride concentration Range (5 - 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 10 | Water intended for human consumption | Permanganate index Range (1,0 -10) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 11 | Water intended for human consumption | Turbidity Range (0,10 – 40) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016 | |
| 12 | Swimming pool water | Nitrate concentration Range (0,18 – 200) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 13 | Swimming pool water | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 14 | Swimming pool water | Permanganate index Range (1,0 -10) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 15 | Swimming pool water | Turbidity Range (0,10 – 40) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016 | |
| 16 | Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN -EN ISO 9308-1:2014-12 | PN -EN ISO 9308-1:2014-12/A1:2017-04 | |
| 17 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN -EN ISO 9308-1:2014-12 | PN -EN ISO 9308-1:2014-12/A1:2017-04 | |
| 18 | Water intended for human consumption | Total viable count at 22°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 19 | Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 20 | Swimming pool water | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 | |
| 21 | Swimming pool water | Total viable count at 36°C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 22 | Swimming pool water | Coagulase-positive staphylococci count | Membrane filtration method | PB-04/LHK Wydanie VI z dnia 22.03.2022 r. | |
| 23 | Swimming pool water | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 24 | Bathing water | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 25 | Bathing water | Most probable number, Escherichia coli | Miniaturized method | PN-EN ISO 9308-3:2002 | |
Reference standards (21)
PB-04/LHK Wydanie VI z dnia 22.03.2022 r.
PN -EN ISO 9308-1:2014-12
PN -EN ISO 9308-1:2014-12/A1:2017-04
PN-82/C-04576/08
PN-92/C-04590/02
PN-C-04576-04:1994
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016
PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/A1:2017-04
PN-EN ISO 9308-3:2002
PN-ISO 6332:2001
PN-ISO 6332:2001/Ap1:2016-06
PN-ISO 9297:1994