{"lab":{"_id":"69ad52a3de79e566650fb3d8","accr_number":"AB 764","country":"PL","accr_body":"PCA","address":"W INOWROCŁAWIU, Plac Klasztorny 1b, 88-100 Inowrocław","categories":["water","microbiology"],"city":"Inowrocław","imported_at":"2026-03-08T10:42:43.265Z","methods_count":25,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_764.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w inowrocławiu, plac klasztorny 1b, 88-100 inowrocław other water pharma electronics microbiology automotive food","status":"active","updated_at":"2026-03-08T14:51:39.216Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-22T00:37:43.285Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20764,podmiot.html","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"},{"codes":"K/28; K/29","pl":"Badania mikrobiologiczne wody, wody do spożycia przez ludzi","en":"Microbiological tests of water, drinking water"}],"issue":{"no":"18","date":"19.08.2026"},"parse_date":"2026-08-22T00:37:43.285Z","parse_source":"agent-claude-code","map_coord":[52.795241,18.259562],"map_geo":"nominatim-city","has_en":true,"lab_locations":[{"name":"Laboratorium Badania Środowiska Komunalnego","address":"Plac Klasztorny 1b, 88-100 Inowrocław","city":"Inowrocław","postal":"88-100"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/21/df1a0b3ecd05b271e764c4694ec6c48a/AB%20764.pdf","category_counts":{"water":25,"microbiology":4},"category_scores":{"water":21.55,"microbiology":0.55},"has_zh":true},"methods":[{"_id":"6a88ef57fbf98dd0af9b22d0","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(30 – 3000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (30 – 3000) μg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/02","norm_bases":["PN-92/C-04590/02"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (30 – 3000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/02 Woda do spozycia przez ludzi Stezenie manganu\nZakres (30 – 3000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590/02","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(30 – 3000) μg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590/02","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22d1","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,18 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,18 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,18 – 200) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,18 – 200) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,18 – 200) mg/l"}],"search_zh":"生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22d2","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,04 – 0,80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,04 – 0,80) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,04 – 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,04 – 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,04 – 0,80) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22d3","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(20 – 5000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (20 – 5000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","norm_bases":["PN-ISO 6332:2001","PN-ISO 6332:2001/Ap1:2016-06"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (20 – 5000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (20 – 5000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20 – 5000) μg/l"}],"search_zh":"生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22d4","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonów amonowych","parameters":[{"name":"Zakres","range":"(0,258 – 2,58) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonów amonowych\nZakres (0,258 – 2,58) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-04:1994","norm_bases":["PN-C-04576-04:1994"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonów amonowych\nZakres (0,258 – 2,58) mg/l\nMetoda spektrofotometryczna PN-C-04576-04:1994 Woda do spozycia przez ludzi Stezenie jonow amonowych\nZakres (0,258 – 2,58) mg/l\nMetoda spektrofotometryczna PN-C-04576-04:1994","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","parameters_zh":[{"name":"范围","range":"(0,258 – 2,58) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 范围 PN-C-04576-04:1994","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"铵离子浓度"},{"_id":"6a88ef57fbf98dd0af9b22d5","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22d6","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda D","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda D"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda D Woda do spozycia przez ludzi Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda D","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"生活饮用水 色度 目视法 范围 PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda D","technique_zh":"目视法","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22d7","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 4900) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 4900) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (100 – 4900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (100 – 4900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 4900) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22d8","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5 - 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5 - 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5 - 400) mg/l"}],"search_zh":"生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22d9","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(1,0 -10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (1,0 -10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (1,0 -10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (1,0 -10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(1,0 -10) mg/l O2"}],"search_zh":"生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22da","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016","norm_bases":["PN-EN ISO 7027-1:2016"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 40) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22db","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,18 – 200) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,18 – 200) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Stężenie azotanów\nZakres (0,18 – 200) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda na plywalniach Stezenie azotanow\nZakres (0,18 – 200) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,18 – 200) mg/l"}],"search_zh":"游泳池水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"游泳池水"},{"_id":"6a88ef57fbf98dd0af9b22dc","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda na plywalniach pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"游泳池水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a88ef57fbf98dd0af9b22dd","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(1,0 -10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (1,0 -10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Indeks nadmanganianowy\nZakres (1,0 -10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda na plywalniach Indeks nadmanganianowy\nZakres (1,0 -10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(1,0 -10) mg/l O2"}],"search_zh":"游泳池水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"游泳池水"},{"_id":"6a88ef57fbf98dd0af9b22de","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 40) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016","norm_bases":["PN-EN ISO 7027-1:2016"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Mętność\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016 Woda na plywalniach Metnosc\nZakres (0,10 – 40) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 40) NTU"}],"search_zh":"游泳池水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016","technique_zh":"浊度法（散射法）","test_object_zh":"游泳池水"},{"_id":"6a88ef57fbf98dd0af9b22df","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN -EN ISO 9308-1:2014-12 | PN -EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN -EN ISO 9308-1:2014-12","PN -EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN -EN ISO 9308-1:2014-12 | PN -EN ISO 9308-1:2014-12/A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN -EN ISO 9308-1:2014-12 | PN -EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN -EN ISO 9308-1:2014-12 | PN -EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22e0","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN -EN ISO 9308-1:2014-12 | PN -EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN -EN ISO 9308-1:2014-12","PN -EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN -EN ISO 9308-1:2014-12 | PN -EN ISO 9308-1:2014-12/A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN -EN ISO 9308-1:2014-12 | PN -EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN -EN ISO 9308-1:2014-12 | PN -EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22e1","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"22°C 微生物总数","search_zh":"生活饮用水 22°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a88ef57fbf98dd0af9b22e2","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków jelitowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków jelitowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"生活饮用水 肠道肠球菌数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"肠道肠球菌数"},{"_id":"6a88ef57fbf98dd0af9b22e3","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12/A1:2017-04"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","categories":["water","microbiology"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a88ef57fbf98dd0af9b22e4","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Ogólna liczba mikroorganizmów w temp. 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w temp. 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"游泳池水 36°C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"游泳池水","methodology_zh":"36°C 微生物总数"},{"_id":"6a88ef57fbf98dd0af9b22e5","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba gronkowców koagulazo-dodatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej","reference":"PB-04/LHK Wydanie VII z dnia 01.08.2025","norm_bases":["PB-04/LHK Wydanie VII z dnia 01.08.2025"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej PB-04/LHK Wydanie VII z dnia 01.08.2025 Woda na plywalniach Liczba gronkowcow koagulazo-dodatnich\nMetoda filtracji membranowej PB-04/LHK Wydanie VII z dnia 01.08.2025","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"游泳池水 凝固酶阳性葡萄球菌计数 膜过滤法 PB-04/LHK Wydanie VII z dnia 01.08.2025","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a88ef57fbf98dd0af9b22e6","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a88ef57fbf98dd0af9b22e7","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda w kąpieliskach","methodology":"Liczba enterokoków jelitowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków jelitowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda w kąpieliskach Liczba enterokoków jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda w kapieliskach Liczba enterokokow jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"浴场水 肠道肠球菌数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"浴场水","methodology_zh":"肠道肠球菌数"},{"_id":"6a88ef57fbf98dd0af9b22e8","lab_id":"69ad52a3de79e566650fb3d8","country":"PL","accr_number":"AB 764","accr_body":"PCA","test_object":"Woda w kąpieliskach","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda zminiaturyzowana","techniques":["Metoda zminiaturyzowana"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda zminiaturyzowana","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":"Laboratorium Badania Środowiska Komunalnego; Plac Klasztorny 1b, 88-100 Inowrocław","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda w kąpieliskach Najbardziej prawdopodobna liczba Escherichia coli\nMetoda zminiaturyzowana PN-EN ISO 9308-3:2002 Woda w kapieliskach Najbardziej prawdopodobna liczba Escherichia coli\nMetoda zminiaturyzowana PN-EN ISO 9308-3:2002","categories":["water","microbiology"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","search_zh":"浴场水 大肠埃希氏菌最可能数 微量法 PN-EN ISO 9308-3:2002","test_object_zh":"浴场水","technique_zh":"微量法","methodology_zh":"大肠埃希氏菌最可能数"}],"has_pdf":true}