🇵🇱 VEOLIA ENERGIA ŁÓDŹ S.A. PL

PCA AB 761 • Łódź, Poland • 85 methods

Petrochemistry & fuelsEnvironment

VEOLIA ENERGIA ŁÓDŹ S.A. is a laboratory accredited by PCA under number AB 761 (Łódź, Poland). Its accreditation scope covers 85 test methods in the following areas: Petrochemistry & fuels, Environment. Test objects include: Waste gases, E – Flexible scope of accreditation. Flexible scope includes the el…, Lista akredytowanych działań prowadzonych w ramach elastycznego zak…, Automated measuring systems (AMS). Most frequently used techniques: Gravimetric method, High-temperature combustion with IR detection, Direct measurement method.

At a glance

  • Accreditation number: PCA AB 761
  • Methods in scope: 85
  • Types of test objects: 12
  • Techniques used: 16
  • City: Łódź, Poland
Accreditation number
AB 761
Accreditation body
PCA
Address
DZIAŁ OCHRONY ŚRODOWISKA I LABORATORIUM, ul. Jadzi Andrzejewskiej 5, 92-550 Łódź
City
Łódź, Poland

What this laboratory tests (12)

Analytical techniques used (16)

Laboratory sections (3)

Laboratory locations

Accreditation scope — test methods (85)

No. Test object Methodology / Parameters Technique Reference document
Laboratorium; Sekcja Badań Paliw
1 Odpady O) E : kod: 10 01 01, 10 01 02, 10 01 24
O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Total carbon content High-temperature combustion with IR detection PN-G-04571
2 Paliwa stałe E - węgiel kamienny
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
First-stage moisture content (free moisture) Gravimetric method PN-ISO 589
3 Paliwa stałe E - węgiel kamienny
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Total moisture content (calculated) PN-ISO 589
4 Paliwa stałe E - węgiel kamienny
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Second-stage moisture content Gravimetric method PN-ISO 589
5 Paliwa stałe E - węgiel kamienny
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Moisture content in the analytical sample Gravimetric method PN-ISO 11722
6 Paliwa stałe E - węgiel kamienny
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Moisture content in the analytical sample Thermogravimetric method (TGA) PN-G-04560
7 Paliwa stałe E - węgiel kamienny
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Ash content Thermogravimetric method (TGA) PN-G-04560
8 Paliwa stałe E - węgiel kamienny
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Ash content Gravimetric method PN-ISO 1171
9 Paliwa stałe E - węgiel kamienny
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Total sulfur content High-temperature combustion with IR detection PN-G-04584
10 Paliwa stałe E - węgiel kamienny
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Hydrogen content High-temperature combustion method with IR detection PN-G-04571
11 Paliwa stałe E - węgiel kamienny
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Total carbon content High-temperature combustion with IR detection PN-G-04571
12 Paliwa stałe E - węgiel kamienny
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Gross calorific value Calorimetric method PN-ISO 1928
13 Paliwa stałe E - węgiel kamienny
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Net calorific value (calculated) PN-ISO 1928
14 Paliwa stałe E - biomasa stała – biopaliwo stałe
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Total moisture content Gravimetric method PN-EN ISO 18134-1
15 Paliwa stałe E - biomasa stała – biopaliwo stałe
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Moisture content in the analytical sample Gravimetric method PN-EN ISO 18134-3
16 Paliwa stałe E - biomasa stała – biopaliwo stałe
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Moisture content in the analytical sample Thermogravimetric method (TGA) PN-EN ISO 18134-3
17 Paliwa stałe E - biomasa stała – biopaliwo stałe
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Ash content Gravimetric method PN-EN ISO 18122
18 Paliwa stałe E - biomasa stała – biopaliwo stałe
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Ash content Thermogravimetric method (TGA) PN-EN ISO 18122
19 Paliwa stałe E - biomasa stała – biopaliwo stałe
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Total sulfur content High-temperature combustion with IR detection PN-EN ISO 16994
20 Paliwa stałe E - biomasa stała – biopaliwo stałe
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Total carbon content High-temperature combustion with IR detection PN-EN ISO 16948
21 Paliwa stałe E - biomasa stała – biopaliwo stałe
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Hydrogen content High-temperature combustion with IR detection PN-EN ISO 16948
22 Paliwa stałe E - biomasa stała – biopaliwo stałe
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Gross calorific value Calorimetric method PN-EN ISO 18125
23 Paliwa stałe E - biomasa stała – biopaliwo stałe
E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.
Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.
Net calorific value (calculated) PN-EN ISO 18125
24 Solid fuels - solid biomass – solid biofuel Total carbon content
Range (23,0 – 80,0) %
High-temperature combustion with TC detection PN-EN ISO 16948:2015-07
25 Solid fuels - solid biomass – solid biofuel Hydrogen content
Range (2,50 – 7,00) %
High-temperature combustion with TC detection PN-EN ISO 16948:2015-07
26 Solid fuels - solid biomass – solid biofuel Nitrogen content
Range (0,10 – 3,00) %
High-temperature combustion with TC detection PN-EN ISO 16948:2015-07
Laboratorium; Sekcja Badań Chemicznych i Środowiskowych
27 Workplace environment - electric lighting Illuminance
Range (0,5 – 9500) lx
Direct measurement method PN-83/E-04040.03
28 Workplace environment - electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
29 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level
Range (25 – 140) dB
Direct measurement method Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F
30 General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F
31 Machinery and equipment – noise A-weighted equivalent sound pressure level
Range (22 – 136) dB
Direct measurement method PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09
32 Machinery and equipment – noise Sound pressure level in 1/3 and 1/1 octave bands
Range of band centre frequencies: 1/3 octave (100 – 10000) Hz 1/1 octave (125 – 8000) Hz
Direct measurement method PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09
33 Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09
Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź
34 Waste gases Gas volume flow rate for dynamic pressures > 10 Pa
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Stagnation pressure method PN-Z-04030-7:1994
35 Waste gases Dust sampling for testing
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-Z-04030-7:1994
36 Waste gases Dust concentration
Range (0,001 - 25) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Gravimetric method PN-Z-04030-7:1994
37 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-Z-04030-7:1994
38 Waste gases Gas volume flow rate for dynamic pressures >10 Pa
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Stagnation pressure method PN-EN 13284-1:2018-02
39 Waste gases Dust sampling for determination of dust concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13284-1:2018-02
40 Waste gases Dust concentration
Range (0,001 – 0,05) g/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Gravimetric method PN-EN 13284-1:2018-02
41 Waste gases Dust emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13284-1:2018-02
42 Waste gases Concentration of carbon dioxide, sulphur dioxide, carbon monoxide
CO2 (0,5 – 20) % SO2 (6 – 3000) mg/m3 CO (4 – 625) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
NDIR method PN-ISO 10396:2001
43 Waste gases Concentration of nitrogen oxides, nitrogen monoxide,
NOx (3 – 2050) mg/m3 NO (2 – 1340) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Chemiluminescence method PN-ISO 10396:2001
44 Waste gases Emission of SO2, NOx (NO and NO2 calculated as NO2), CO, NO (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-ISO 10396:2001
45 Waste gases Sampling for determination of SO2 concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14791:2017-04
46 Waste gases SO2 concentration
Range (5 – 2000) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Thoron method PN-EN 14791:2017-04
47 Waste gases SO2 emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14791:2017-04
48 Waste gases Concentration of nitrogen oxides, nitrogen monoxide,
NOx (3 – 2050) mg/m3 NO (2 – 1340) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Chemiluminescence method PN-EN 14792:2017-04
49 Waste gases NO, NOx emission (NO and NO2 calculated as NO2) (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14792:2017-04
50 Waste gases O2 concentration
Range (2 – 25) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Paramagnetic method PN-EN 14789:2017-04
51 Waste gases O2 concentration
Range (2 – 25) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Paramagnetic method PN-ISO 10396:2001
52 Waste gases CO concentration
Range (4 – 625) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
NDIR method PN-EN 15058:2017-04
53 Waste gases CO emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 15058:2017-04
54 Waste gases H2O concentration
Range (29 – 250) g/m3 Range (4 – 40) %
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Condensation-adsorption method PN-EN 14790:2017-04
55 Waste gases Sampling for determination of total mercury concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13211+AC:2006
56 Waste gases Total mercury emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 13211+AC:2006
57 Waste gases Sampling for determination of hydrogen chloride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 1911:2011
58 Waste gases Hydrogen chloride concentration
Range (0,8 – 350) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Spectrophotometric method PN-EN 1911:2011
59 Waste gases HCl emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 1911:2011
60 Waste gases Sampling for determination of hydrogen fluoride concentration
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
ISO 15713:2006
61 Waste gases Hydrogen fluoride concentration
Range (0,2 – 20) mg/m3
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Potentiometric method using an ion-selective electrode ISO 15713:2006
62 Waste gases HF emission (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
ISO 15713:2006
63 Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14385:2025-05
64 Waste gases Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se (calculated)
Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14385:2025-05
65 Automated measuring systems (AMS) Annual surveillance test (AST) for: dust, NOx, SO2, O2, CO2 , CO, H2O, HF, HCl
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14181:2015
66 Automated measuring systems (AMS) AMS calibration (QAL2) for: dust NOx, SO2, O2, CO2 , CO, H2O, HF, HCl
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
PN-EN 14181:2015
67 Automated measuring systems (AMS) Dust concentration
Range (0,001 – 25) g/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Gravimetric method PN-Z-04030-7:1994
68 Automated measuring systems (AMS) Dust concentration
Range (0,001 – 0,05) g/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Gravimetric method PN-EN 13284-1:2018-02
69 Automated measuring systems (AMS) NOx concentration calculated as NO2
Range (3 – 2050) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Chemiluminescence method PN-EN 14792:2017-04
70 Automated measuring systems (AMS) SO2 concentration
Range (5 – 2000) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Thoron method PN-EN 14791: 2017-04
71 Automated measuring systems (AMS) O2 concentration
Range (2 – 25) %
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Paramagnetic method PN-EN 14789:2017-04
72 Automated measuring systems (AMS) CO2 concentration
Range (0,5 – 20) %
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
NDIR method PN-ISO 10396:2001
73 Automated measuring systems (AMS) CO concentration
Range (4 – 625) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
NDIR method PN-EN 15058:2017-04
74 Automated measuring systems (AMS) H2O concentration
Range (29 – 250) g/m3 Range (4 – 40) %
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Condensation-adsorption method PN-EN 14790:2017-04
75 Automated measuring systems (AMS) Hydrogen chloride concentration
Range (0,8 – 350) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Spectrophotometric method PN-EN 1911:2011
76 Automated measuring systems (AMS) Hydrogen fluoride concentration
Range (0,2 – 20) mg/m3
Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law
Potentiometric method using an ion-selective electrode ISO 15713:2006
77 Waste gases Sampling for determination of ammonia concentration PN-EN ISO 21877:2020-03
78 Waste gases Ammonia concentration
Range (0,2 – 20) mg/m3
Spectrophotometric method PN-EN ISO 21877:2020-03
79 Waste gases NH3 emission (calculated) PN-EN ISO 21877:2020-03
80 Waste gases Sampling for determination of the concentration of sulfuric acid, including sulfur trioxide Aspiration method using absorbing solutions SE.PB.01 edycja nr 1 z 10.03.2021 r.
81 Waste gases Sulphuric acid concentration, including sulphur trioxide
Range (2 – 50) mg/m3
Thoron method SE.PB.01 edycja nr 1 z 10.03.2021 r.
82 Waste gases Emission of H2SO4 and SO3 (calculated) SE.PB.01 edycja nr 1 z 10.03.2021 r.
83 Automated measuring systems (AMS) Annual surveillance test (AST) for NH3 PN-EN 14181:2015
84 Automated measuring systems (AMS) AMS calibration (QAL2) for NH3 PN-EN 14181:2015
85 Automated measuring systems (AMS) Ammonia concentration
Range (0,2 – 20) mg/m3
Spectrophotometric method PN-EN ISO 21877:2020-03

Reference standards (35)

ISO 15713:2006
PN-83/E-04040.03
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 14181:2015
PN-EN 14385:2025-05
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791: 2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 1911:2011
PN-EN ISO 16948
PN-EN ISO 16948:2015-07
PN-EN ISO 16994
PN-EN ISO 18122
PN-EN ISO 18125
PN-EN ISO 18134-1
PN-EN ISO 18134-3
PN-EN ISO 21877:2020-03
PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3
PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4
PN-EN ISO 3746:2011/Ap1:2017-09
PN-G-04560
PN-G-04571
PN-G-04584
PN-ISO 10396:2001
PN-ISO 1171
PN-ISO 11722
PN-ISO 1928
PN-ISO 589
PN-Z-04030-7:1994
SE.PB.01 edycja nr 1 z 10.03.2021 r.
Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F