🇵🇱 VEOLIA ENERGIA ŁÓDŹ S.A. PL
Petrochemistry & fuelsEnvironment
VEOLIA ENERGIA ŁÓDŹ S.A. is a laboratory accredited by PCA under number AB 761 (Łódź, Poland). Its accreditation scope covers 85 test methods in the following areas: Petrochemistry & fuels, Environment. Test objects include: Waste gases, E – Flexible scope of accreditation. Flexible scope includes the el…, Lista akredytowanych działań prowadzonych w ramach elastycznego zak…, Automated measuring systems (AMS). Most frequently used techniques: Gravimetric method, High-temperature combustion with IR detection, Direct measurement method.
At a glance
- Accreditation number: PCA AB 761
- Methods in scope: 85
- Types of test objects: 12
- Techniques used: 16
- City: Łódź, Poland
- Accreditation number
- AB 761
- Accreditation body
- PCA
- Address
- DZIAŁ OCHRONY ŚRODOWISKA I LABORATORIUM, ul. Jadzi Andrzejewskiej 5, 92-550 Łódź
- City
- Łódź, Poland
What this laboratory tests (12)
- Waste gases — 37 methods
- E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. — 23 methods
- Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. — 23 methods
- Automated measuring systems (AMS) — 15 methods
- Paliwa stałe E - węgiel kamienny — 12 methods
- Paliwa stałe E - biomasa stała – biopaliwo stałe — 10 methods
- Machinery and equipment – noise — 3 methods
- Solid fuels - solid biomass – solid biofuel — 3 methods
- General environment - noise from installations, equipment and industrial plants — 2 methods
- Workplace environment - electric lighting — 2 methods
- O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów — 1 method
- Odpady O) E : kod: 10 01 01, 10 01 02, 10 01 24 — 1 method
Analytical techniques used (16)
- Gravimetric method — 11 methods
- High-temperature combustion with IR detection — 6 methods
- Direct measurement method — 4 methods
- NDIR method — 4 methods
- Spectrophotometric method — 4 methods
- Thermogravimetric method (TGA) — 4 methods
- Chemiluminescence method — 3 methods
- High-temperature combustion with TC detection — 3 methods
- Paramagnetic method — 3 methods
- Thoron method — 3 methods
- Calorimetric method — 2 methods
- Condensation-adsorption method — 2 methods
- Potentiometric method using an ion-selective electrode — 2 methods
- Stagnation pressure method — 2 methods
- Aspiration method using absorbing solutions — 1 method
- and 1 more
Laboratory sections (3)
- Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź — 52 methods
- Laboratorium; Sekcja Badań Paliw — 26 methods
- Laboratorium; Sekcja Badań Chemicznych i Środowiskowych — 7 methods
Laboratory locations
- DZIAŁ OCHRONY ŚRODOWISKA I LABORATORIUM — ul. Jadzi Andrzejewskiej 5
- Sekcja Badań Paliw — ul. Jadzi Andrzejewskiej 5, 92-550 Łódź
- Sekcja Badań Chemicznych i Środowiskowych — ul. Jadzi Andrzejewskiej 5, 92-550 Łódź
- Sekcja Pomiarów Emisyjnych — Jadzi Andrzejewskiej 5, 92-550 Łódź
- Laboratorium; Sekcja Badań Chemicznych i Środowiskowych —
- Laboratorium; Sekcja Badań Paliw —
- Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź —
Accreditation scope — test methods (85)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratorium; Sekcja Badań Paliw | |||||
| 1 | Odpady O) E : kod: 10 01 01, 10 01 02, 10 01 24 O) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Total carbon content | High-temperature combustion with IR detection | PN-G-04571 | |
| 2 | Paliwa stałe E - węgiel kamienny E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
First-stage moisture content (free moisture) | Gravimetric method | PN-ISO 589 | |
| 3 | Paliwa stałe E - węgiel kamienny E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Total moisture content (calculated) | PN-ISO 589 | ||
| 4 | Paliwa stałe E - węgiel kamienny E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Second-stage moisture content | Gravimetric method | PN-ISO 589 | |
| 5 | Paliwa stałe E - węgiel kamienny E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Moisture content in the analytical sample | Gravimetric method | PN-ISO 11722 | |
| 6 | Paliwa stałe E - węgiel kamienny E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Moisture content in the analytical sample | Thermogravimetric method (TGA) | PN-G-04560 | |
| 7 | Paliwa stałe E - węgiel kamienny E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Ash content | Thermogravimetric method (TGA) | PN-G-04560 | |
| 8 | Paliwa stałe E - węgiel kamienny E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Ash content | Gravimetric method | PN-ISO 1171 | |
| 9 | Paliwa stałe E - węgiel kamienny E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Total sulfur content | High-temperature combustion with IR detection | PN-G-04584 | |
| 10 | Paliwa stałe E - węgiel kamienny E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Hydrogen content | High-temperature combustion method with IR detection | PN-G-04571 | |
| 11 | Paliwa stałe E - węgiel kamienny E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Total carbon content | High-temperature combustion with IR detection | PN-G-04571 | |
| 12 | Paliwa stałe E - węgiel kamienny E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Gross calorific value | Calorimetric method | PN-ISO 1928 | |
| 13 | Paliwa stałe E - węgiel kamienny E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Net calorific value (calculated) | PN-ISO 1928 | ||
| 14 | Paliwa stałe E - biomasa stała – biopaliwo stałe E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Total moisture content | Gravimetric method | PN-EN ISO 18134-1 | |
| 15 | Paliwa stałe E - biomasa stała – biopaliwo stałe E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Moisture content in the analytical sample | Gravimetric method | PN-EN ISO 18134-3 | |
| 16 | Paliwa stałe E - biomasa stała – biopaliwo stałe E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Moisture content in the analytical sample | Thermogravimetric method (TGA) | PN-EN ISO 18134-3 | |
| 17 | Paliwa stałe E - biomasa stała – biopaliwo stałe E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Ash content | Gravimetric method | PN-EN ISO 18122 | |
| 18 | Paliwa stałe E - biomasa stała – biopaliwo stałe E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Ash content | Thermogravimetric method (TGA) | PN-EN ISO 18122 | |
| 19 | Paliwa stałe E - biomasa stała – biopaliwo stałe E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Total sulfur content | High-temperature combustion with IR detection | PN-EN ISO 16994 | |
| 20 | Paliwa stałe E - biomasa stała – biopaliwo stałe E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Total carbon content | High-temperature combustion with IR detection | PN-EN ISO 16948 | |
| 21 | Paliwa stałe E - biomasa stała – biopaliwo stałe E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Hydrogen content | High-temperature combustion with IR detection | PN-EN ISO 16948 | |
| 22 | Paliwa stałe E - biomasa stała – biopaliwo stałe E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Gross calorific value | Calorimetric method | PN-EN ISO 18125 | |
| 23 | Paliwa stałe E - biomasa stała – biopaliwo stałe E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. Lista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. |
Net calorific value (calculated) | PN-EN ISO 18125 | ||
| 24 | Solid fuels - solid biomass – solid biofuel | Total carbon content Range (23,0 – 80,0) % |
High-temperature combustion with TC detection | PN-EN ISO 16948:2015-07 | |
| 25 | Solid fuels - solid biomass – solid biofuel | Hydrogen content Range (2,50 – 7,00) % |
High-temperature combustion with TC detection | PN-EN ISO 16948:2015-07 | |
| 26 | Solid fuels - solid biomass – solid biofuel | Nitrogen content Range (0,10 – 3,00) % |
High-temperature combustion with TC detection | PN-EN ISO 16948:2015-07 | |
| Laboratorium; Sekcja Badań Chemicznych i Środowiskowych | |||||
| 27 | Workplace environment - electric lighting | Illuminance Range (0,5 – 9500) lx |
Direct measurement method | PN-83/E-04040.03 | |
| 28 | Workplace environment - electric lighting | Illuminance uniformity (calculated) | PN-83/E-04040.03 | ||
| 29 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level Range (25 – 140) dB |
Direct measurement method | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F | |
| 30 | General environment - noise from installations, equipment and industrial plants | A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) | Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F | ||
| 31 | Machinery and equipment – noise | A-weighted equivalent sound pressure level Range (22 – 136) dB |
Direct measurement method | PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 | |
| 32 | Machinery and equipment – noise | Sound pressure level in 1/3 and 1/1 octave bands Range of band centre frequencies: 1/3 octave (100 – 10000) Hz 1/1 octave (125 – 8000) Hz |
Direct measurement method | PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 | |
| 33 | Machinery and equipment – noise | Sound power level (calculated) | PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 | ||
| Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź | |||||
| 34 | Waste gases | Gas volume flow rate for dynamic pressures > 10 Pa Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Stagnation pressure method | PN-Z-04030-7:1994 | |
| 35 | Waste gases | Dust sampling for testing Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 36 | Waste gases | Dust concentration Range (0,001 - 25) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-Z-04030-7:1994 | |
| 37 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-Z-04030-7:1994 | ||
| 38 | Waste gases | Gas volume flow rate for dynamic pressures >10 Pa Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Stagnation pressure method | PN-EN 13284-1:2018-02 | |
| 39 | Waste gases | Dust sampling for determination of dust concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13284-1:2018-02 | ||
| 40 | Waste gases | Dust concentration Range (0,001 – 0,05) g/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 41 | Waste gases | Dust emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13284-1:2018-02 | ||
| 42 | Waste gases | Concentration of carbon dioxide, sulphur dioxide, carbon monoxide CO2 (0,5 – 20) % SO2 (6 – 3000) mg/m3 CO (4 – 625) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
NDIR method | PN-ISO 10396:2001 | |
| 43 | Waste gases | Concentration of nitrogen oxides, nitrogen monoxide, NOx (3 – 2050) mg/m3 NO (2 – 1340) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Chemiluminescence method | PN-ISO 10396:2001 | |
| 44 | Waste gases | Emission of SO2, NOx (NO and NO2 calculated as NO2), CO, NO (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-ISO 10396:2001 | ||
| 45 | Waste gases | Sampling for determination of SO2 concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14791:2017-04 | ||
| 46 | Waste gases | SO2 concentration Range (5 – 2000) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Thoron method | PN-EN 14791:2017-04 | |
| 47 | Waste gases | SO2 emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14791:2017-04 | ||
| 48 | Waste gases | Concentration of nitrogen oxides, nitrogen monoxide, NOx (3 – 2050) mg/m3 NO (2 – 1340) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Chemiluminescence method | PN-EN 14792:2017-04 | |
| 49 | Waste gases | NO, NOx emission (NO and NO2 calculated as NO2) (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14792:2017-04 | ||
| 50 | Waste gases | O2 concentration Range (2 – 25) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Paramagnetic method | PN-EN 14789:2017-04 | |
| 51 | Waste gases | O2 concentration Range (2 – 25) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Paramagnetic method | PN-ISO 10396:2001 | |
| 52 | Waste gases | CO concentration Range (4 – 625) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
NDIR method | PN-EN 15058:2017-04 | |
| 53 | Waste gases | CO emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 15058:2017-04 | ||
| 54 | Waste gases | H2O concentration Range (29 – 250) g/m3 Range (4 – 40) % Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Condensation-adsorption method | PN-EN 14790:2017-04 | |
| 55 | Waste gases | Sampling for determination of total mercury concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13211+AC:2006 | ||
| 56 | Waste gases | Total mercury emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 13211+AC:2006 | ||
| 57 | Waste gases | Sampling for determination of hydrogen chloride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1911:2011 | ||
| 58 | Waste gases | Hydrogen chloride concentration Range (0,8 – 350) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Spectrophotometric method | PN-EN 1911:2011 | |
| 59 | Waste gases | HCl emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 1911:2011 | ||
| 60 | Waste gases | Sampling for determination of hydrogen fluoride concentration Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 15713:2006 | ||
| 61 | Waste gases | Hydrogen fluoride concentration Range (0,2 – 20) mg/m3 Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Potentiometric method using an ion-selective electrode | ISO 15713:2006 | |
| 62 | Waste gases | HF emission (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
ISO 15713:2006 | ||
| 63 | Waste gases | Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14385:2025-05 | ||
| 64 | Waste gases | Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se (calculated) Regulated area: Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14385:2025-05 | ||
| 65 | Automated measuring systems (AMS) | Annual surveillance test (AST) for: dust, NOx, SO2, O2, CO2 , CO, H2O, HF, HCl Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14181:2015 | ||
| 66 | Automated measuring systems (AMS) | AMS calibration (QAL2) for: dust NOx, SO2, O2, CO2 , CO, H2O, HF, HCl Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
PN-EN 14181:2015 | ||
| 67 | Automated measuring systems (AMS) | Dust concentration Range (0,001 – 25) g/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-Z-04030-7:1994 | |
| 68 | Automated measuring systems (AMS) | Dust concentration Range (0,001 – 0,05) g/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Gravimetric method | PN-EN 13284-1:2018-02 | |
| 69 | Automated measuring systems (AMS) | NOx concentration calculated as NO2 Range (3 – 2050) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Chemiluminescence method | PN-EN 14792:2017-04 | |
| 70 | Automated measuring systems (AMS) | SO2 concentration Range (5 – 2000) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Thoron method | PN-EN 14791: 2017-04 | |
| 71 | Automated measuring systems (AMS) | O2 concentration Range (2 – 25) % Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Paramagnetic method | PN-EN 14789:2017-04 | |
| 72 | Automated measuring systems (AMS) | CO2 concentration Range (0,5 – 20) % Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
NDIR method | PN-ISO 10396:2001 | |
| 73 | Automated measuring systems (AMS) | CO concentration Range (4 – 625) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
NDIR method | PN-EN 15058:2017-04 | |
| 74 | Automated measuring systems (AMS) | H2O concentration Range (29 – 250) g/m3 Range (4 – 40) % Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Condensation-adsorption method | PN-EN 14790:2017-04 | |
| 75 | Automated measuring systems (AMS) | Hydrogen chloride concentration Range (0,8 – 350) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Spectrophotometric method | PN-EN 1911:2011 | |
| 76 | Automated measuring systems (AMS) | Hydrogen fluoride concentration Range (0,2 – 20) mg/m3 Regulated area: Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area
The competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law |
Potentiometric method using an ion-selective electrode | ISO 15713:2006 | |
| 77 | Waste gases | Sampling for determination of ammonia concentration | PN-EN ISO 21877:2020-03 | ||
| 78 | Waste gases | Ammonia concentration Range (0,2 – 20) mg/m3 |
Spectrophotometric method | PN-EN ISO 21877:2020-03 | |
| 79 | Waste gases | NH3 emission (calculated) | PN-EN ISO 21877:2020-03 | ||
| 80 | Waste gases | Sampling for determination of the concentration of sulfuric acid, including sulfur trioxide | Aspiration method using absorbing solutions | SE.PB.01 edycja nr 1 z 10.03.2021 r. | |
| 81 | Waste gases | Sulphuric acid concentration, including sulphur trioxide Range (2 – 50) mg/m3 |
Thoron method | SE.PB.01 edycja nr 1 z 10.03.2021 r. | |
| 82 | Waste gases | Emission of H2SO4 and SO3 (calculated) | SE.PB.01 edycja nr 1 z 10.03.2021 r. | ||
| 83 | Automated measuring systems (AMS) | Annual surveillance test (AST) for NH3 | PN-EN 14181:2015 | ||
| 84 | Automated measuring systems (AMS) | AMS calibration (QAL2) for NH3 | PN-EN 14181:2015 | ||
| 85 | Automated measuring systems (AMS) | Ammonia concentration Range (0,2 – 20) mg/m3 |
Spectrophotometric method | PN-EN ISO 21877:2020-03 | |
Reference standards (35)
ISO 15713:2006
PN-83/E-04040.03
PN-EN 13211+AC:2006
PN-EN 13284-1:2018-02
PN-EN 14181:2015
PN-EN 14385:2025-05
PN-EN 14789:2017-04
PN-EN 14790:2017-04
PN-EN 14791: 2017-04
PN-EN 14791:2017-04
PN-EN 14792:2017-04
PN-EN 15058:2017-04
PN-EN 1911:2011
PN-EN ISO 16948
PN-EN ISO 16948:2015-07
PN-EN ISO 16994
PN-EN ISO 18122
PN-EN ISO 18125
PN-EN ISO 18134-1
PN-EN ISO 18134-3
PN-EN ISO 21877:2020-03
PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3
PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4
PN-EN ISO 3746:2011/Ap1:2017-09
PN-G-04560
PN-G-04571
PN-G-04584
PN-ISO 10396:2001
PN-ISO 1171
PN-ISO 11722
PN-ISO 1928
PN-ISO 589
PN-Z-04030-7:1994
SE.PB.01 edycja nr 1 z 10.03.2021 r.