{"lab":{"_id":"69ad52a3de79e566650fb3d4","accr_number":"AB 761","country":"PL","accr_body":"PCA","address":"DZIAŁ OCHRONY ŚRODOWISKA I LABORATORIUM, ul. Jadzi Andrzejewskiej 5, 92-550 Łódź","categories":["petro","environment"],"city":"Łódź","imported_at":"2026-03-08T10:42:43.265Z","methods_count":85,"name":"VEOLIA ENERGIA ŁÓDŹ S.A.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_761.pdf"],"scope_summary":"","search_text":"veolia energia łódź s.a. dział ochrony środowiska i laboratorium, ul. jadzi andrzejewskiej 5, 92-550 łódź environment other materials petro pharma electronics metrology","status":"active","updated_at":"2026-03-08T14:51:39.103Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:05:09.194Z","location":{"type":"Point","coordinates":[19.456,51.7592]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20761,plik.html","fields_of_testing":[{"codes":"A/13","pl":"Badanie akustyczne i drgań – maszyny i urządzenia","en":"Acoustic and vibration tests – machinery and devices"},{"codes":"C/10, C/32","pl":"Badania chemiczne paliw stałych, odpadów","en":"Chemical tests of solid fuels wastes"},{"codes":"C/36/P","pl":"Badania chemiczne i pobieranie próbek gazów odlotowych","en":"Chemical tests and sampling of waste gases"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki uciążliwe – oświetlenie)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (nuisance factors – lighting)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – hałas)","en":"Tests concerning environmental engineering (environmental and climatic) - general environment (physical factors – noise)"},{"codes":"G/36","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – gazy (gazy odlotowe)","en":"Tests concerning environmental engineering (environmental and climatic) – gases (waste gases)"},{"codes":"M/58","pl":"Badania inne QAL2 i AST automatycznych systemów monitoringu (AMS)","en":"Other tests QAL2 and AST of Automatic Monitoring Systems (AMS)"},{"codes":"N/10","pl":"Badania właściwości fizycznych paliw stałych","en":"Tests of physical properties of solid fuels"},{"codes":"N/36/P","pl":"Badania właściwości fizycznych i pobieranie próbek gazów odlotowych","en":"Tests of physical properties and sampling of waste gases"}],"issue":{"no":"35","date":"15.06.2026"},"parse_date":"2026-08-18T01:05:09.194Z","parse_source":"agent-claude-code","map_coord":[51.746695,19.539861],"map_geo":"nominatim-street","lab_locations":[{"name":"DZIAŁ OCHRONY ŚRODOWISKA I LABORATORIUM","address":"ul. Jadzi Andrzejewskiej 5","city":null,"postal":null},{"name":"Sekcja Badań Paliw","address":"ul. Jadzi Andrzejewskiej 5, 92-550 Łódź","city":"Łódź","postal":"92-550"},{"name":"Sekcja Badań Chemicznych i Środowiskowych","address":"ul. Jadzi Andrzejewskiej 5, 92-550 Łódź","city":"Łódź","postal":"92-550"},{"name":"Sekcja Pomiarów Emisyjnych","address":"Jadzi Andrzejewskiej 5, 92-550 Łódź","city":"Łódź","postal":"92-550"},{"name":"Laboratorium; Sekcja Badań Chemicznych i Środowiskowych","address":null,"city":null,"postal":null},{"name":"Laboratorium; Sekcja Badań Paliw","address":null,"city":null,"postal":null},{"name":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/6fbf37989edac566a85da65c025b9d4d/AB%20761.pdf","has_en":true,"category_counts":{"other":37,"petro":25,"environment":20,"metrology":2,"materials":1},"category_scores":{"other":16.11,"petro":7.35,"environment":4.71,"metrology":0.05,"materials":0.01},"has_zh":true},"methods":[{"_id":"6a83afc5af14b9c0e7b2065d","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Odpady O) E : kod: 10 01 01, 10 01 02, 10 01 24\nO) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość węgla całkowitego","parameters":[],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571","norm_bases":["PN-G-04571"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Odpady O) E : kod: 10 01 01, 10 01 02, 10 01 24\nO) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość węgla całkowitego\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571 Odpady O) E : kod: 10 01 01, 10 01 02, 10 01 24\nO) Kody odpadow wedlug Rozporzadzenia Ministra Klimatu w sprawie katalogu odpadow\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wegla calkowitego\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","search_en":"Odpady O) E : kod: 10 01 01, 10 01 02, 10 01 24\nO) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Total carbon content High-temperature combustion with IR detection PN-G-04571","technique_en":"High-temperature combustion with IR detection","test_object_en":"Odpady O) E : kod: 10 01 01, 10 01 02, 10 01 24\nO) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"总碳含量","search_zh":"Odpady O) E : kod: 10 01 01, 10 01 02, 10 01 24\nO) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 总碳含量 高温燃烧红外检测法 PN-G-04571","technique_zh":"高温燃烧红外检测法","test_object_zh":"Odpady O) E : kod: 10 01 01, 10 01 02, 10 01 24\nO) Kody odpadów według Rozporządzenia Ministra Klimatu w sprawie katalogu odpadów\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b2065e","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nMetoda wagowa","reference":"PN-ISO 589","norm_bases":["PN-ISO 589"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość wilgoci pierwszego stopnia (wilgoci przemijającej)\nMetoda wagowa PN-ISO 589 Paliwa stale E - wegiel kamienny\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wilgoci pierwszego stopnia (wilgoci przemijajacej)\nMetoda wagowa PN-ISO 589","categories":["petro"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"First-stage moisture content (free moisture)","search_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. First-stage moisture content (free moisture) Gravimetric method PN-ISO 589","technique_en":"Gravimetric method","test_object_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","search_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 第一阶段水分（外在水分）含量 重量法 PN-ISO 589","technique_zh":"重量法","test_object_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"第一阶段水分（外在水分）含量"},{"_id":"6a83afc5af14b9c0e7b2065f","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość wilgoci całkowitej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Zawartość wilgoci całkowitej (z obliczeń)","reference":"PN-ISO 589","norm_bases":["PN-ISO 589"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość wilgoci całkowitej (z obliczeń) PN-ISO 589 Paliwa stale E - wegiel kamienny\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wilgoci calkowitej (z obliczen) PN-ISO 589","categories":["petro"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content (calculated)","search_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Total moisture content (calculated) PN-ISO 589","test_object_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","search_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 全水分含量（计算值） PN-ISO 589","test_object_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"全水分含量（计算值）"},{"_id":"6a83afc5af14b9c0e7b20660","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość wilgoci drugiego stopnia","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci drugiego stopnia\nMetoda wagowa","reference":"PN-ISO 589","norm_bases":["PN-ISO 589"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość wilgoci drugiego stopnia\nMetoda wagowa PN-ISO 589 Paliwa stale E - wegiel kamienny\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wilgoci drugiego stopnia\nMetoda wagowa PN-ISO 589","categories":["petro"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Second-stage moisture content","search_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Second-stage moisture content Gravimetric method PN-ISO 589","technique_en":"Gravimetric method","test_object_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","search_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 第二阶段水分含量 重量法 PN-ISO 589","technique_zh":"重量法","test_object_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"第二阶段水分含量"},{"_id":"6a83afc5af14b9c0e7b20661","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nMetoda wagowa","reference":"PN-ISO 11722","norm_bases":["PN-ISO 11722"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość wilgoci w próbce analitycznej\nMetoda wagowa PN-ISO 11722 Paliwa stale E - wegiel kamienny\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wilgoci w probce analitycznej\nMetoda wagowa PN-ISO 11722","categories":["petro"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","search_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Moisture content in the analytical sample Gravimetric method PN-ISO 11722","technique_en":"Gravimetric method","test_object_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"分析样品水分含量","search_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 分析样品水分含量 重量法 PN-ISO 11722","technique_zh":"重量法","test_object_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b20662","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560","norm_bases":["PN-G-04560"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość wilgoci w próbce analitycznej\nMetoda termograwimetryczna (TGA) PN-G-04560 Paliwa stale E - wegiel kamienny\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wilgoci w probce analitycznej\nMetoda termograwimetryczna (TGA) PN-G-04560","categories":["petro"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","search_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Moisture content in the analytical sample Thermogravimetric method (TGA) PN-G-04560","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"分析样品水分含量","search_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 分析样品水分含量 热重法（TGA） PN-G-04560","technique_zh":"热重法（TGA）","test_object_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b20663","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość popiołu","parameters":[],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nMetoda termograwimetryczna (TGA)","reference":"PN-G-04560","norm_bases":["PN-G-04560"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość popiołu\nMetoda termograwimetryczna (TGA) PN-G-04560 Paliwa stale E - wegiel kamienny\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc popiolu\nMetoda termograwimetryczna (TGA) PN-G-04560","categories":["petro"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","search_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Ash content Thermogravimetric method (TGA) PN-G-04560","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"灰分含量","search_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 灰分含量 热重法（TGA） PN-G-04560","technique_zh":"热重法（TGA）","test_object_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b20664","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość popiołu","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nMetoda wagowa","reference":"PN-ISO 1171","norm_bases":["PN-ISO 1171"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość popiołu\nMetoda wagowa PN-ISO 1171 Paliwa stale E - wegiel kamienny\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc popiolu\nMetoda wagowa PN-ISO 1171","categories":["petro"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","search_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Ash content Gravimetric method PN-ISO 1171","technique_en":"Gravimetric method","test_object_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"灰分含量","search_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 灰分含量 重量法 PN-ISO 1171","technique_zh":"重量法","test_object_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b20665","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość siarki całkowitej","parameters":[],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04584","norm_bases":["PN-G-04584"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość siarki całkowitej\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04584 Paliwa stale E - wegiel kamienny\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc siarki calkowitej\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04584","categories":["petro"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","search_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Total sulfur content High-temperature combustion with IR detection PN-G-04584","technique_en":"High-temperature combustion with IR detection","test_object_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"全硫含量","search_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 全硫含量 高温燃烧红外检测法 PN-G-04584","technique_zh":"高温燃烧红外检测法","test_object_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b20666","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość wodoru","parameters":[],"technique":"Metoda wysokotemperaturowa spalania z detekcją IR","techniques":["Metoda wysokotemperaturowa spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nMetoda wysokotemperaturowa spalania z detekcją IR","reference":"PN-G-04571","norm_bases":["PN-G-04571"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość wodoru\nMetoda wysokotemperaturowa spalania z detekcją IR PN-G-04571 Paliwa stale E - wegiel kamienny\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wodoru\nMetoda wysokotemperaturowa spalania z detekcja IR PN-G-04571","categories":["petro"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","search_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Hydrogen content High-temperature combustion method with IR detection PN-G-04571","technique_en":"High-temperature combustion method with IR detection","test_object_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","search_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 氢含量 PN-G-04571","test_object_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"氢含量"},{"_id":"6a83afc5af14b9c0e7b20667","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość węgla całkowitego","parameters":[],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-G-04571","norm_bases":["PN-G-04571"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość węgla całkowitego\nMetoda wysokotemperaturowego spalania z detekcją IR PN-G-04571 Paliwa stale E - wegiel kamienny\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wegla calkowitego\nMetoda wysokotemperaturowego spalania z detekcja IR PN-G-04571","categories":["petro"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","search_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Total carbon content High-temperature combustion with IR detection PN-G-04571","technique_en":"High-temperature combustion with IR detection","test_object_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"总碳含量","search_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 总碳含量 高温燃烧红外检测法 PN-G-04571","technique_zh":"高温燃烧红外检测法","test_object_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b20668","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Ciepło spalania","parameters":[],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nMetoda kalorymetryczna","reference":"PN-ISO 1928","norm_bases":["PN-ISO 1928"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Ciepło spalania\nMetoda kalorymetryczna PN-ISO 1928 Paliwa stale E - wegiel kamienny\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Cieplo spalania\nMetoda kalorymetryczna PN-ISO 1928","categories":["petro"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","search_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Gross calorific value Calorimetric method PN-ISO 1928","technique_en":"Calorimetric method","test_object_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"高位发热量","search_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 高位发热量 量热法 PN-ISO 1928","technique_zh":"量热法","test_object_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b20669","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-ISO 1928","norm_bases":["PN-ISO 1928"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - węgiel kamienny\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Wartość opałowa (z obliczeń) PN-ISO 1928 Paliwa stale E - wegiel kamienny\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Wartosc opalowa (z obliczen) PN-ISO 1928","categories":["petro"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Net calorific value (calculated) PN-ISO 1928","test_object_en":"Paliwa stałe E - węgiel kamienny\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"低位发热量（计算值）","search_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 低位发热量（计算值） PN-ISO 1928","test_object_zh":"Paliwa stałe E - węgiel kamienny\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b2066a","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość wilgoci całkowitej","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci całkowitej\nMetoda wagowa","reference":"PN-EN ISO 18134-1","norm_bases":["PN-EN ISO 18134-1"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość wilgoci całkowitej\nMetoda wagowa PN-EN ISO 18134-1 Paliwa stale E - biomasa stala – biopaliwo stale\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wilgoci calkowitej\nMetoda wagowa PN-EN ISO 18134-1","categories":["petro"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total moisture content","search_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Total moisture content Gravimetric method PN-EN ISO 18134-1","technique_en":"Gravimetric method","test_object_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"全水分含量","search_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 全水分含量 重量法 PN-EN ISO 18134-1","technique_zh":"重量法","test_object_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b2066b","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nMetoda wagowa","reference":"PN-EN ISO 18134-3","norm_bases":["PN-EN ISO 18134-3"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość wilgoci w próbce analitycznej\nMetoda wagowa PN-EN ISO 18134-3 Paliwa stale E - biomasa stala – biopaliwo stale\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wilgoci w probce analitycznej\nMetoda wagowa PN-EN ISO 18134-3","categories":["petro"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","search_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Moisture content in the analytical sample Gravimetric method PN-EN ISO 18134-3","technique_en":"Gravimetric method","test_object_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"分析样品水分含量","search_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 分析样品水分含量 重量法 PN-EN ISO 18134-3","technique_zh":"重量法","test_object_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b2066c","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość wilgoci w próbce analitycznej","parameters":[],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość wilgoci w próbce analitycznej\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18134-3","norm_bases":["PN-EN ISO 18134-3"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość wilgoci w próbce analitycznej\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3 Paliwa stale E - biomasa stala – biopaliwo stale\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wilgoci w probce analitycznej\nMetoda termograwimetryczna (TGA) PN-EN ISO 18134-3","categories":["petro"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Moisture content in the analytical sample","search_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Moisture content in the analytical sample Thermogravimetric method (TGA) PN-EN ISO 18134-3","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"分析样品水分含量","search_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 分析样品水分含量 热重法（TGA） PN-EN ISO 18134-3","technique_zh":"热重法（TGA）","test_object_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b2066d","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość popiołu","parameters":[],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu\nMetoda wagowa","reference":"PN-EN ISO 18122","norm_bases":["PN-EN ISO 18122"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość popiołu\nMetoda wagowa PN-EN ISO 18122 Paliwa stale E - biomasa stala – biopaliwo stale\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc popiolu\nMetoda wagowa PN-EN ISO 18122","categories":["petro"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","search_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Ash content Gravimetric method PN-EN ISO 18122","technique_en":"Gravimetric method","test_object_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"灰分含量","search_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 灰分含量 重量法 PN-EN ISO 18122","technique_zh":"重量法","test_object_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b2066e","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość popiołu","parameters":[],"technique":"Metoda termograwimetryczna (TGA)","techniques":["Metoda termograwimetryczna (TGA)"],"computed":[],"activity":"Zawartość popiołu\nMetoda termograwimetryczna (TGA)","reference":"PN-EN ISO 18122","norm_bases":["PN-EN ISO 18122"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość popiołu\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122 Paliwa stale E - biomasa stala – biopaliwo stale\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc popiolu\nMetoda termograwimetryczna (TGA) PN-EN ISO 18122","categories":["petro"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ash content","search_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Ash content Thermogravimetric method (TGA) PN-EN ISO 18122","technique_en":"Thermogravimetric method (TGA)","test_object_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"灰分含量","search_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 灰分含量 热重法（TGA） PN-EN ISO 18122","technique_zh":"热重法（TGA）","test_object_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b2066f","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość siarki całkowitej","parameters":[],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość siarki całkowitej\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16994","norm_bases":["PN-EN ISO 16994"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość siarki całkowitej\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16994 Paliwa stale E - biomasa stala – biopaliwo stale\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc siarki calkowitej\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16994","categories":["petro"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total sulfur content","search_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Total sulfur content High-temperature combustion with IR detection PN-EN ISO 16994","technique_en":"High-temperature combustion with IR detection","test_object_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"全硫含量","search_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 全硫含量 高温燃烧红外检测法 PN-EN ISO 16994","technique_zh":"高温燃烧红外检测法","test_object_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b20670","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość węgla całkowitego","parameters":[],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość węgla całkowitego\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948","norm_bases":["PN-EN ISO 16948"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość węgla całkowitego\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948 Paliwa stale E - biomasa stala – biopaliwo stale\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wegla calkowitego\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948","categories":["petro"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","search_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Total carbon content High-temperature combustion with IR detection PN-EN ISO 16948","technique_en":"High-temperature combustion with IR detection","test_object_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"总碳含量","search_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 总碳含量 高温燃烧红外检测法 PN-EN ISO 16948","technique_zh":"高温燃烧红外检测法","test_object_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b20671","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Zawartość wodoru","parameters":[],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Zawartość wodoru\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN ISO 16948","norm_bases":["PN-EN ISO 16948"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Zawartość wodoru\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN ISO 16948 Paliwa stale E - biomasa stala – biopaliwo stale\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Zawartosc wodoru\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN ISO 16948","categories":["petro"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","search_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Hydrogen content High-temperature combustion with IR detection PN-EN ISO 16948","technique_en":"High-temperature combustion with IR detection","test_object_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","search_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 氢含量 高温燃烧红外检测法 PN-EN ISO 16948","technique_zh":"高温燃烧红外检测法","test_object_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"氢含量"},{"_id":"6a83afc5af14b9c0e7b20672","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Ciepło spalania","parameters":[],"technique":"Metoda kalorymetryczna","techniques":["Metoda kalorymetryczna"],"computed":[],"activity":"Ciepło spalania\nMetoda kalorymetryczna","reference":"PN-EN ISO 18125","norm_bases":["PN-EN ISO 18125"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Ciepło spalania\nMetoda kalorymetryczna PN-EN ISO 18125 Paliwa stale E - biomasa stala – biopaliwo stale\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Cieplo spalania\nMetoda kalorymetryczna PN-EN ISO 18125","categories":["petro"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gross calorific value","search_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Gross calorific value Calorimetric method PN-EN ISO 18125","technique_en":"Calorimetric method","test_object_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"高位发热量","search_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 高位发热量 量热法 PN-EN ISO 18125","technique_zh":"量热法","test_object_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b20673","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology":"Wartość opałowa (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wartość opałowa (z obliczeń)","reference":"PN-EN ISO 18125","norm_bases":["PN-EN ISO 18125"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Wartość opałowa (z obliczeń) PN-EN ISO 18125 Paliwa stale E - biomasa stala – biopaliwo stale\nE – Elastyczny zakres akredytacji. Elastycznosc zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriow badawczych.\nLista akredytowanych dzialan prowadzonych w ramach elastycznego zakresu akredytacji jest udostepniana na zadanie przez akredytowany podmiot. Wartosc opalowa (z obliczen) PN-EN ISO 18125","categories":["petro"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Net calorific value (calculated)","search_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. Net calorific value (calculated) PN-EN ISO 18125","test_object_en":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories.\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot.","methodology_zh":"低位发热量（计算值）","search_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot. 低位发热量（计算值） PN-EN ISO 18125","test_object_zh":"Paliwa stałe E - biomasa stała – biopaliwo stałe\nE — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。\nLista akredytowanych działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana na żądanie przez akredytowany podmiot."},{"_id":"6a83afc5af14b9c0e7b20674","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe - biomasa stała – biopaliwo stałe","methodology":"Zawartość węgla całkowitego","parameters":[{"name":"Zakres","range":"(23,0 – 80,0) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość węgla całkowitego\nZakres (23,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe - biomasa stała – biopaliwo stałe Zawartość węgla całkowitego\nZakres (23,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN ISO 16948:2015-07 Paliwa stale - biomasa stala – biopaliwo stale Zawartosc wegla calkowitego\nZakres (23,0 – 80,0) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total carbon content","parameters_en":[{"name":"Range","range":"(23,0 – 80,0) %"}],"search_en":"Solid fuels - solid biomass – solid biofuel Total carbon content High-temperature combustion with TC detection Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels - solid biomass – solid biofuel","methodology_zh":"总碳含量","parameters_zh":[{"name":"范围","range":"(23,0 – 80,0) %"}],"search_zh":"固体燃料 － 固体生物质 － 固体生物燃料 总碳含量 高温燃烧总碳检测法 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧总碳检测法","test_object_zh":"固体燃料 － 固体生物质 － 固体生物燃料"},{"_id":"6a83afc5af14b9c0e7b20675","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe - biomasa stała – biopaliwo stałe","methodology":"Zawartość wodoru","parameters":[{"name":"Zakres","range":"(2,50 – 7,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość wodoru\nZakres (2,50 – 7,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe - biomasa stała – biopaliwo stałe Zawartość wodoru\nZakres (2,50 – 7,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN ISO 16948:2015-07 Paliwa stale - biomasa stala – biopaliwo stale Zawartosc wodoru\nZakres (2,50 – 7,00) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen content","parameters_en":[{"name":"Range","range":"(2,50 – 7,00) %"}],"search_en":"Solid fuels - solid biomass – solid biofuel Hydrogen content High-temperature combustion with TC detection Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels - solid biomass – solid biofuel","parameters_zh":[{"name":"范围","range":"(2,50 – 7,00) %"}],"search_zh":"固体燃料 － 固体生物质 － 固体生物燃料 氢含量 高温燃烧总碳检测法 范围 PN-EN ISO 16948:2015-07","methodology_zh":"氢含量","technique_zh":"高温燃烧总碳检测法","test_object_zh":"固体燃料 － 固体生物质 － 固体生物燃料"},{"_id":"6a83afc5af14b9c0e7b20676","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Paliwa stałe - biomasa stała – biopaliwo stałe","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,10 – 3,00) %"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją TC","techniques":["Metoda wysokotemperaturowego spalania z detekcją TC"],"computed":[],"activity":"Zawartość azotu\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC","reference":"PN-EN ISO 16948:2015-07","norm_bases":["PN-EN ISO 16948:2015-07"],"lab_section":"Laboratorium; Sekcja Badań Paliw","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Paliwa stałe - biomasa stała – biopaliwo stałe Zawartość azotu\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcją TC PN-EN ISO 16948:2015-07 Paliwa stale - biomasa stala – biopaliwo stale Zawartosc azotu\nZakres (0,10 – 3,00) %\nMetoda wysokotemperaturowego spalania z detekcja TC PN-EN ISO 16948:2015-07","categories":["petro"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 – 3,00) %"}],"search_en":"Solid fuels - solid biomass – solid biofuel Nitrogen content High-temperature combustion with TC detection Range PN-EN ISO 16948:2015-07","technique_en":"High-temperature combustion with TC detection","test_object_en":"Solid fuels - solid biomass – solid biofuel","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,10 – 3,00) %"}],"search_zh":"固体燃料 － 固体生物质 － 固体生物燃料 氮含量 高温燃烧总碳检测法 范围 PN-EN ISO 16948:2015-07","technique_zh":"高温燃烧总碳检测法","test_object_zh":"固体燃料 － 固体生物质 － 固体生物燃料"},{"_id":"6a83afc5af14b9c0e7b20677","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 – 9500) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 – 9500) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium; Sekcja Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne Natężenie oświetlenia\nZakres (0,5 – 9500) lx\nMetoda pomiarowa bezpośrednia PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne Natezenie oswietlenia\nZakres (0,5 – 9500) lx\nMetoda pomiarowa bezposrednia PN-83/E-04040.03","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 – 9500) lx"}],"search_en":"Workplace environment - electric lighting Illuminance Direct measurement method Range PN-83/E-04040.03","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 – 9500) lx"}],"search_zh":"工作环境 － 电气照明 照度 直接测量法 范围 PN-83/E-04040.03","technique_zh":"直接测量法","test_object_zh":"工作环境 － 电气照明"},{"_id":"6a83afc5af14b9c0e7b20678","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PN-83/E-04040.03","norm_bases":["PN-83/E-04040.03"],"lab_section":"Laboratorium; Sekcja Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne Równomierność oświetlenia (z obliczeń) PN-83/E-04040.03 Srodowisko pracy - oswietlenie elektryczne Rownomiernosc oswietlenia (z obliczen) PN-83/E-04040.03","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03","test_object_en":"Workplace environment - electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作环境 － 电气照明 照度均匀度（计算值） PN-83/E-04040.03","test_object_zh":"工作环境 － 电气照明"},{"_id":"6a83afc5af14b9c0e7b20679","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(25 – 140) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (25 – 140) dB\nMetoda pomiarowa bezpośrednia","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium; Sekcja Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A\nZakres (25 – 140) dB\nMetoda pomiarowa bezpośrednia Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A\nZakres (25 – 140) dB\nMetoda pomiarowa bezposrednia Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(25 – 140) dB"}],"search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level Direct measurement method Range Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","technique_en":"Direct measurement method","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(25 – 140) dB"}],"search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 A 计权等效声级 直接测量法 范围 Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","technique_zh":"直接测量法","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a83afc5af14b9c0e7b2067a","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych","methodology":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń)","reference":"Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","norm_bases":["Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F"],"lab_section":"Laboratorium; Sekcja Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko ogólne - hałas pochodzący od instalacji, urządzeń i zakładów przemysłowych Równoważny poziom dźwięku A dla czasu odniesienia T wyrażony wskaźnikami LAeqD i LAeqN (z obliczeń) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F Srodowisko ogolne - halas pochodzacy od instalacji, urzadzen i zakladow przemyslowych Rownowazny poziom dzwieku A dla czasu odniesienia T wyrazony wskaznikami LAeqD i LAeqN (z obliczen) Zalacznik nr 7 do Rozporzadzenia Ministra Klimatu i Srodowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wylaczeniem punktu F","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated)","search_en":"General environment - noise from installations, equipment and industrial plants A-weighted equivalent sound pressure level for the reference time T expressed by the indicators LAeqD and LAeqN (calculated) Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","test_object_en":"General environment - noise from installations, equipment and industrial plants","methodology_zh":"参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值）","search_zh":"一般环境 — 来自装置、设备和工业企业的噪声 参考时间 T 的 A 计权等效声级，以 LAeqD 和 LAeqN 表示（计算值） Załącznik nr 7 do Rozporządzenia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) z wyłączeniem punktu F","test_object_zh":"一般环境 — 来自装置、设备和工业企业的噪声"},{"_id":"6a83afc5af14b9c0e7b2067b","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Równoważny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(22 – 136) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A\nZakres (22 – 136) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3","PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":"Laboratorium; Sekcja Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Równoważny poziom dźwięku A\nZakres (22 – 136) dB\nMetoda pomiarowa bezpośrednia PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia – halas Rownowazny poziom dzwieku A\nZakres (22 – 136) dB\nMetoda pomiarowa bezposrednia PN-EN ISO 3744:2011 z wylaczeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wylaczeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"A-weighted equivalent sound pressure level","parameters_en":[{"name":"Range","range":"(22 – 136) dB"}],"search_en":"Machinery and equipment – noise A-weighted equivalent sound pressure level Direct measurement method Range PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment – noise","methodology_zh":"A 计权等效声级","parameters_zh":[{"name":"范围","range":"(22 – 136) dB"}],"search_zh":"机器与设备 – 噪声 A 计权等效声级 直接测量法 范围 PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_zh":"直接测量法","test_object_zh":"机器与设备 – 噪声"},{"_id":"6a83afc5af14b9c0e7b2067c","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Poziom ciśnienia akustycznego w pasmach 1/3 i 1/1 oktawowych","parameters":[{"name":"Zakres częstotliwości środkowych pasm:"},{"name":"1/3 oktawowych","range":"(100 – 10000) Hz"},{"name":"1/1 oktawowych","range":"(125 – 8000) Hz"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Poziom ciśnienia akustycznego w pasmach 1/3 i 1/1 oktawowych\nZakres:\nZakres częstotliwości środkowych pasm:\n1/3 oktawowych (100 – 10000) Hz\n1/1 oktawowych (125 – 8000) Hz\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3","PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":"Laboratorium; Sekcja Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Poziom ciśnienia akustycznego w pasmach 1/3 i 1/1 oktawowych\nZakres:\nZakres częstotliwości środkowych pasm:\n1/3 oktawowych (100 – 10000) Hz\n1/1 oktawowych (125 – 8000) Hz\nMetoda pomiarowa bezpośrednia PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia – halas Poziom cisnienia akustycznego w pasmach 1/3 i 1/1 oktawowych\nZakres:\nZakres czestotliwosci srodkowych pasm:\n1/3 oktawowych (100 – 10000) Hz\n1/1 oktawowych (125 – 8000) Hz\nMetoda pomiarowa bezposrednia PN-EN ISO 3744:2011 z wylaczeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wylaczeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound pressure level in 1/3 and 1/1 octave bands","parameters_en":[{"name":"Range of band centre frequencies:"},{"name":"1/3 octave","range":"(100 – 10000) Hz"},{"name":"1/1 octave","range":"(125 – 8000) Hz"}],"search_en":"Machinery and equipment – noise Sound pressure level in 1/3 and 1/1 octave bands Direct measurement method Range of band centre frequencies: 1/3 octave 1/1 octave PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_en":"Direct measurement method","test_object_en":"Machinery and equipment – noise","parameters_zh":[{"name":"Zakres częstotliwości środkowych pasm:"},{"name":"1/3 倍频程","range":"(100 – 10000) Hz"},{"name":"1/1 oktawowych","range":"(125 – 8000) Hz"}],"search_zh":"机器与设备 – 噪声 直接测量法 1/3 倍频程 PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","technique_zh":"直接测量法","test_object_zh":"机器与设备 – 噪声"},{"_id":"6a83afc5af14b9c0e7b2067d","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Maszyny i urządzenia – hałas","methodology":"Poziom mocy akustycznej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Poziom mocy akustycznej (z obliczeń)","reference":"PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","norm_bases":["PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3","PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4","PN-EN ISO 3746:2011/Ap1:2017-09"],"lab_section":"Laboratorium; Sekcja Badań Chemicznych i Środowiskowych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Maszyny i urządzenia – hałas Poziom mocy akustycznej (z obliczeń) PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09 Maszyny i urzadzenia – halas Poziom mocy akustycznej (z obliczen) PN-EN ISO 3744:2011 z wylaczeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wylaczeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sound power level (calculated)","search_en":"Machinery and equipment – noise Sound power level (calculated) PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","test_object_en":"Machinery and equipment – noise","search_zh":"机器与设备 – 噪声 声功率级（计算值） PN-EN ISO 3744:2011 z wyłączeniem pkt. 8.3 | PN-EN ISO 3746:2011 z wyłączeniem pkt. 8.4 | PN-EN ISO 3746:2011/Ap1:2017-09","test_object_zh":"机器与设备 – 噪声","methodology_zh":"声功率级（计算值）"},{"_id":"6a83afc5af14b9c0e7b2067e","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa","parameters":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych > 10 Pa\nMetoda spiętrzenia PN-Z-04030-7:1994 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych > 10 Pa\nMetoda spietrzenia PN-Z-04030-7:1994","categories":["other"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas volume flow rate for dynamic pressures > 10 Pa","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Gas volume flow rate for dynamic pressures > 10 Pa Stagnation pressure method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","technique_en":"Stagnation pressure method","test_object_en":"Waste gases","search_zh":"废气 动压 > 10 Pa 时的气体体积流量 滞止压力法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"动压 > 10 Pa 时的气体体积流量","technique_zh":"滞止压力法"},{"_id":"6a83afc5af14b9c0e7b2067f","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek pyłu do badań","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu do badań","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do badań PN-Z-04030-7:1994 Gazy odlotowe Pobieranie probek pylu do badan PN-Z-04030-7:1994","categories":["other"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust sampling for testing","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust sampling for testing Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 用于检验的粉尘采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"用于检验的粉尘采样"},{"_id":"6a83afc5af14b9c0e7b20680","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 - 25) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 - 25) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 - 25) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Gazy odlotowe Stezenie pylu\nZakres (0,001 - 25) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 - 25) g/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust concentration Gravimetric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 - 25) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-Z-04030-7:1994","technique_zh":"重量法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83afc5af14b9c0e7b20681","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-Z-04030-7:1994 Gazy odlotowe Emisja pylu (z obliczen) PN-Z-04030-7:1994","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-Z-04030-7:1994","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-Z-04030-7:1994","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83afc5af14b9c0e7b20682","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Strumień objętości gazu dla ciśnień dynamicznych >10 Pa","parameters":[],"technique":"Metoda spiętrzenia","techniques":["Metoda spiętrzenia"],"computed":[],"activity":"Strumień objętości gazu dla ciśnień dynamicznych >10 Pa\nMetoda spiętrzenia","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Strumień objętości gazu dla ciśnień dynamicznych >10 Pa\nMetoda spiętrzenia PN-EN 13284-1:2018-02 Gazy odlotowe Strumien objetosci gazu dla cisnien dynamicznych >10 Pa\nMetoda spietrzenia PN-EN 13284-1:2018-02","categories":["other"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Gas volume flow rate for dynamic pressures >10 Pa","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Gas volume flow rate for dynamic pressures >10 Pa Stagnation pressure method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13284-1:2018-02","technique_en":"Stagnation pressure method","test_object_en":"Waste gases","search_zh":"废气 动压 >10 Pa 时的气体体积流量 滞止压力法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13284-1:2018-02","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"滞止压力法","methodology_zh":"动压 >10 Pa 时的气体体积流量"},{"_id":"6a83afc5af14b9c0e7b20683","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek pyłu do oznaczania stężenia pyłu","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek pyłu do oznaczania stężenia pyłu","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek pyłu do oznaczania stężenia pyłu PN-EN 13284-1:2018-02 Gazy odlotowe Pobieranie probek pylu do oznaczania stezenia pylu PN-EN 13284-1:2018-02","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust sampling for determination of dust concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust sampling for determination of dust concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 用于测定粉尘浓度的粉尘采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13284-1:2018-02","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"用于测定粉尘浓度的粉尘采样"},{"_id":"6a83afc5af14b9c0e7b20684","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 – 0,05) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 – 0,05) g/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie pyłu\nZakres (0,001 – 0,05) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Gazy odlotowe Stezenie pylu\nZakres (0,001 – 0,05) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 – 0,05) g/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust concentration Gravimetric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Waste gases","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 0,05) g/m3"}],"search_zh":"废气 粉尘浓度 重量法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83afc5af14b9c0e7b20685","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja pyłu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja pyłu (z obliczeń)","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja pyłu (z obliczeń) PN-EN 13284-1:2018-02 Gazy odlotowe Emisja pylu (z obliczen) PN-EN 13284-1:2018-02","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Dust emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13284-1:2018-02","test_object_en":"Waste gases","search_zh":"废气 粉尘排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13284-1:2018-02","test_object_zh":"废气","methodology_zh":"粉尘排放量（计算值）","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83afc5af14b9c0e7b20686","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie dwutlenku węgla, dwutlenku siarki, tlenku węgla","parameters":[{"name":"CO2","range":"(0,5 – 20) %"},{"name":"SO2","range":"(6 – 3000) mg/m3"},{"name":"CO","range":"(4 – 625) mg/m3"}],"technique":"Metoda NDIR","techniques":["Metoda NDIR"],"computed":[],"activity":"Stężenie dwutlenku węgla, dwutlenku siarki, tlenku węgla\nZakres:\nCO2 (0,5 – 20) %\nSO2 (6 – 3000) mg/m3\nCO (4 – 625) mg/m3\nMetoda NDIR","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie dwutlenku węgla, dwutlenku siarki, tlenku węgla\nZakres:\nCO2 (0,5 – 20) %\nSO2 (6 – 3000) mg/m3\nCO (4 – 625) mg/m3\nMetoda NDIR PN-ISO 10396:2001 Gazy odlotowe Stezenie dwutlenku wegla, dwutlenku siarki, tlenku wegla\nZakres:\nCO2 (0,5 – 20) %\nSO2 (6 – 3000) mg/m3\nCO (4 – 625) mg/m3\nMetoda NDIR PN-ISO 10396:2001","categories":["other"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of carbon dioxide, sulphur dioxide, carbon monoxide","parameters_en":[{"name":"CO2","range":"(0,5 – 20) %"},{"name":"SO2","range":"(6 – 3000) mg/m3"},{"name":"CO","range":"(4 – 625) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Concentration of carbon dioxide, sulphur dioxide, carbon monoxide NDIR method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law CO2 SO2 CO PN-ISO 10396:2001","technique_en":"NDIR method","test_object_en":"Waste gases","search_zh":"废气 二氧化碳、二氧化硫、一氧化碳浓度 非分散红外法（NDIR） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 CO2 SO2 CO PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"CO2","range":"(0,5 – 20) %"},{"name":"SO2","range":"(6 – 3000) mg/m3"},{"name":"CO","range":"(4 – 625) mg/m3"}],"regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"非分散红外法（NDIR）","methodology_zh":"二氧化碳、二氧化硫、一氧化碳浓度"},{"_id":"6a83afc5af14b9c0e7b20687","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenków azotu, tlenku azotu,","parameters":[{"name":"NOx","range":"(3 – 2050) mg/m3"},{"name":"NO","range":"(2 – 1340) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie tlenków azotu, tlenku azotu,\nZakres:\nNOx (3 – 2050) mg/m3\nNO (2 – 1340) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenków azotu, tlenku azotu,\nZakres:\nNOx (3 – 2050) mg/m3\nNO (2 – 1340) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001 Gazy odlotowe Stezenie tlenkow azotu, tlenku azotu,\nZakres:\nNOx (3 – 2050) mg/m3\nNO (2 – 1340) mg/m3\nMetoda chemiluminescencyjna PN-ISO 10396:2001","categories":["other"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of nitrogen oxides, nitrogen monoxide,","parameters_en":[{"name":"NOx","range":"(3 – 2050) mg/m3"},{"name":"NO","range":"(2 – 1340) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Concentration of nitrogen oxides, nitrogen monoxide, Chemiluminescence method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law NOx NO PN-ISO 10396:2001","technique_en":"Chemiluminescence method","test_object_en":"Waste gases","search_zh":"废气 化学发光法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 NOx NO PN-ISO 10396:2001","test_object_zh":"废气","parameters_zh":[{"name":"NOx","range":"(3 – 2050) mg/m3"},{"name":"NO","range":"(2 – 1340) mg/m3"}],"regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"化学发光法"},{"_id":"6a83afc5af14b9c0e7b20688","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2, NOx (NO i NO2 w przeliczeniu na NO2), CO, NO (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2, NOx (NO i NO2 w przeliczeniu na NO2), CO, NO (z obliczeń)","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja SO2, NOx (NO i NO2 w przeliczeniu na NO2), CO, NO (z obliczeń) PN-ISO 10396:2001 Gazy odlotowe Emisja SO2, NOx (NO i NO2 w przeliczeniu na NO2), CO, NO (z obliczen) PN-ISO 10396:2001","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of SO2, NOx (NO and NO2 calculated as NO2), CO, NO (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of SO2, NOx (NO and NO2 calculated as NO2), CO, NO (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-ISO 10396:2001","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-ISO 10396:2001","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83afc5af14b9c0e7b20689","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia SO2","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia SO2","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia SO2 PN-EN 14791:2017-04 Gazy odlotowe Pobieranie probek do oznaczania stezenia SO2 PN-EN 14791:2017-04","categories":["other"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of SO2 concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of SO2 concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14791:2017-04","test_object_en":"Waste gases","search_zh":"废气 用于测定 SO2 浓度的采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14791:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"用于测定 SO2 浓度的采样"},{"_id":"6a83afc5af14b9c0e7b2068a","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie SO2","parameters":[{"name":"Zakres","range":"(5 – 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie SO2\nZakres (5 – 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie SO2\nZakres (5 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04 Gazy odlotowe Stezenie SO2\nZakres (5 – 2000) mg/m3\nMetoda toronowa PN-EN 14791:2017-04","categories":["other"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 concentration","parameters_en":[{"name":"Range","range":"(5 – 2000) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases SO2 concentration Thoron method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 14791:2017-04","technique_en":"Thoron method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(5 – 2000) mg/m3"}],"search_zh":"废气 SO2 浓度 钍射气法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 14791:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"钍射气法","methodology_zh":"SO2 浓度"},{"_id":"6a83afc5af14b9c0e7b2068b","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja SO2 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja SO2 (z obliczeń)","reference":"PN-EN 14791:2017-04","norm_bases":["PN-EN 14791:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja SO2 (z obliczeń) PN-EN 14791:2017-04 Gazy odlotowe Emisja SO2 (z obliczen) PN-EN 14791:2017-04","categories":["environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases SO2 emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14791:2017-04","test_object_en":"Waste gases","search_zh":"废气 SO2 排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14791:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"SO2 排放量（计算值）"},{"_id":"6a83afc5af14b9c0e7b2068c","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie tlenków azotu, tlenku azotu,","parameters":[{"name":"NOx","range":"(3 – 2050) mg/m3"},{"name":"NO","range":"(2 – 1340) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie tlenków azotu, tlenku azotu,\nZakres:\nNOx (3 – 2050) mg/m3\nNO (2 – 1340) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie tlenków azotu, tlenku azotu,\nZakres:\nNOx (3 – 2050) mg/m3\nNO (2 – 1340) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 Gazy odlotowe Stezenie tlenkow azotu, tlenku azotu,\nZakres:\nNOx (3 – 2050) mg/m3\nNO (2 – 1340) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04","categories":["other"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of nitrogen oxides, nitrogen monoxide,","parameters_en":[{"name":"NOx","range":"(3 – 2050) mg/m3"},{"name":"NO","range":"(2 – 1340) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Concentration of nitrogen oxides, nitrogen monoxide, Chemiluminescence method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law NOx NO PN-EN 14792:2017-04","technique_en":"Chemiluminescence method","test_object_en":"Waste gases","search_zh":"废气 化学发光法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 NOx NO PN-EN 14792:2017-04","test_object_zh":"废气","parameters_zh":[{"name":"NOx","range":"(3 – 2050) mg/m3"},{"name":"NO","range":"(2 – 1340) mg/m3"}],"regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"化学发光法"},{"_id":"6a83afc5af14b9c0e7b2068d","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń)","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczeń) PN-EN 14792:2017-04 Gazy odlotowe Emisja NO, NOx (NO i NO2 w przeliczeniu na NO2) (z obliczen) PN-EN 14792:2017-04","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NO, NOx emission (NO and NO2 calculated as NO2) (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases NO, NOx emission (NO and NO2 calculated as NO2) (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14792:2017-04","test_object_en":"Waste gases","search_zh":"废气 NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14792:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"NO、NOx（NO 与 NO2 以 NO2 计）排放（由计算得出）"},{"_id":"6a83afc5af14b9c0e7b2068e","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie O2","parameters":[{"name":"Zakres","range":"(2 – 25) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie O2\nZakres (2 – 25) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie O2\nZakres (2 – 25) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 Gazy odlotowe Stezenie O2\nZakres (2 – 25) %\nMetoda paramagnetyczna PN-EN 14789:2017-04","categories":["other"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"O2 concentration","parameters_en":[{"name":"Range","range":"(2 – 25) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases O2 concentration Paramagnetic method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 14789:2017-04","technique_en":"Paramagnetic method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2 – 25) %"}],"search_zh":"废气 O2 浓度 顺磁法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 14789:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"顺磁法","methodology_zh":"O2 浓度"},{"_id":"6a83afc5af14b9c0e7b2068f","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie O2","parameters":[{"name":"Zakres","range":"(2 – 25) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie O2\nZakres (2 – 25) %\nMetoda paramagnetyczna","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie O2\nZakres (2 – 25) %\nMetoda paramagnetyczna PN-ISO 10396:2001 Gazy odlotowe Stezenie O2\nZakres (2 – 25) %\nMetoda paramagnetyczna PN-ISO 10396:2001","categories":["other"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"O2 concentration","parameters_en":[{"name":"Range","range":"(2 – 25) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases O2 concentration Paramagnetic method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-ISO 10396:2001","technique_en":"Paramagnetic method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2 – 25) %"}],"search_zh":"废气 O2 浓度 顺磁法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-ISO 10396:2001","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"顺磁法","methodology_zh":"O2 浓度"},{"_id":"6a83afc5af14b9c0e7b20690","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie CO","parameters":[{"name":"Zakres","range":"(4 – 625) mg/m3"}],"technique":"Metoda NDIR","techniques":["Metoda NDIR"],"computed":[],"activity":"Stężenie CO\nZakres (4 – 625) mg/m3\nMetoda NDIR","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie CO\nZakres (4 – 625) mg/m3\nMetoda NDIR PN-EN 15058:2017-04 Gazy odlotowe Stezenie CO\nZakres (4 – 625) mg/m3\nMetoda NDIR PN-EN 15058:2017-04","categories":["other"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO concentration","parameters_en":[{"name":"Range","range":"(4 – 625) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases CO concentration NDIR method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 15058:2017-04","technique_en":"NDIR method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(4 – 625) mg/m3"}],"search_zh":"废气 CO 浓度 非分散红外法（NDIR） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 15058:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"CO 浓度","technique_zh":"非分散红外法（NDIR）"},{"_id":"6a83afc5af14b9c0e7b20691","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja CO (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja CO (z obliczeń)","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja CO (z obliczeń) PN-EN 15058:2017-04 Gazy odlotowe Emisja CO (z obliczen) PN-EN 15058:2017-04","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases CO emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 15058:2017-04","test_object_en":"Waste gases","search_zh":"废气 CO 排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 15058:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"CO 排放量（计算值）"},{"_id":"6a83afc5af14b9c0e7b20692","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie H2O","parameters":[{"name":"Zakres","range":"(29 – 250) g/m3"},{"name":"Zakres","range":"(4 – 40) %"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"computed":[],"activity":"Stężenie H2O\nZakres:\nZakres (29 – 250) g/m3\nZakres (4 – 40) %\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie H2O\nZakres:\nZakres (29 – 250) g/m3\nZakres (4 – 40) %\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Gazy odlotowe Stezenie H2O\nZakres:\nZakres (29 – 250) g/m3\nZakres (4 – 40) %\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"H2O concentration","parameters_en":[{"name":"Range","range":"(29 – 250) g/m3"},{"name":"Range","range":"(4 – 40) %"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases H2O concentration Condensation-adsorption method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range Range PN-EN 14790:2017-04","technique_en":"Condensation-adsorption method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(29 – 250) g/m3"},{"name":"范围","range":"(4 – 40) %"}],"search_zh":"废气 冷凝-吸附法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 范围 PN-EN 14790:2017-04","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"冷凝-吸附法"},{"_id":"6a83afc5af14b9c0e7b20693","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia rtęci ogólnej","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia rtęci ogólnej PN-EN 13211+AC:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia rteci ogolnej PN-EN 13211+AC:2006","categories":["other"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of total mercury concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of total mercury concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13211+AC:2006","test_object_en":"Waste gases","search_zh":"废气 总汞浓度测定采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13211+AC:2006","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"总汞浓度测定采样"},{"_id":"6a83afc5af14b9c0e7b20694","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja rtęci ogólnej (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja rtęci ogólnej (z obliczeń)","reference":"PN-EN 13211+AC:2006","norm_bases":["PN-EN 13211+AC:2006"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja rtęci ogólnej (z obliczeń) PN-EN 13211+AC:2006 Gazy odlotowe Emisja rteci ogolnej (z obliczen) PN-EN 13211+AC:2006","categories":["environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total mercury emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Total mercury emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 13211+AC:2006","test_object_en":"Waste gases","search_zh":"废气 总汞排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 13211+AC:2006","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"总汞排放量（计算值）"},{"_id":"6a83afc5af14b9c0e7b20695","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia chlorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia chlorowodoru","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia chlorowodoru PN-EN 1911:2011 Gazy odlotowe Pobieranie probek do oznaczania stezenia chlorowodoru PN-EN 1911:2011","categories":["other"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of hydrogen chloride concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of hydrogen chloride concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 1911:2011","test_object_en":"Waste gases","search_zh":"废气 氯化氢浓度测定采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 1911:2011","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氯化氢浓度测定采样"},{"_id":"6a83afc5af14b9c0e7b20696","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie chlorowodoru","parameters":[{"name":"Zakres","range":"(0,8 – 350) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorowodoru\nZakres (0,8 – 350) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie chlorowodoru\nZakres (0,8 – 350) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 Gazy odlotowe Stezenie chlorowodoru\nZakres (0,8 – 350) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration","parameters_en":[{"name":"Range","range":"(0,8 – 350) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Hydrogen chloride concentration Spectrophotometric method Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,8 – 350) mg/m3"}],"search_zh":"废气 氯化氢浓度 分光光度法 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 1911:2011","technique_zh":"分光光度法","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氯化氢浓度"},{"_id":"6a83afc5af14b9c0e7b20697","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja HCl (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja HCl (z obliczeń)","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja HCl (z obliczeń) PN-EN 1911:2011 Gazy odlotowe Emisja HCl (z obliczen) PN-EN 1911:2011","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"HCl emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases HCl emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 1911:2011","test_object_en":"Waste gases","search_zh":"废气 HCl 排放（由计算得出） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 1911:2011","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"HCl 排放（由计算得出）"},{"_id":"6a83afc5af14b9c0e7b20698","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia fluorowodoru","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia fluorowodoru","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia fluorowodoru ISO 15713:2006 Gazy odlotowe Pobieranie probek do oznaczania stezenia fluorowodoru ISO 15713:2006","categories":["other"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of hydrogen fluoride concentration","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of hydrogen fluoride concentration Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law ISO 15713:2006","test_object_en":"Waste gases","search_zh":"废气 氟化氢浓度测定采样 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 ISO 15713:2006","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氟化氢浓度测定采样"},{"_id":"6a83afc5af14b9c0e7b20699","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie fluorowodoru","parameters":[{"name":"Zakres","range":"(0,2 – 20) mg/m3"}],"technique":"Metoda potencjometryczna z zastosowaniem elektrody jonoselektywnej","techniques":["Metoda potencjometryczna z zastosowaniem elektrody jonoselektywnej"],"computed":[],"activity":"Stężenie fluorowodoru\nZakres (0,2 – 20) mg/m3\nMetoda potencjometryczna z zastosowaniem elektrody jonoselektywnej","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Stężenie fluorowodoru\nZakres (0,2 – 20) mg/m3\nMetoda potencjometryczna z zastosowaniem elektrody jonoselektywnej ISO 15713:2006 Gazy odlotowe Stezenie fluorowodoru\nZakres (0,2 – 20) mg/m3\nMetoda potencjometryczna z zastosowaniem elektrody jonoselektywnej ISO 15713:2006","categories":["other"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen fluoride concentration","parameters_en":[{"name":"Range","range":"(0,2 – 20) mg/m3"}],"regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Hydrogen fluoride concentration Potentiometric method using an ion-selective electrode Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range ISO 15713:2006","technique_en":"Potentiometric method using an ion-selective electrode","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,2 – 20) mg/m3"}],"search_zh":"废气 氟化氢浓度 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 ISO 15713:2006","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氟化氢浓度"},{"_id":"6a83afc5af14b9c0e7b2069a","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja HF (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja HF (z obliczeń)","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja HF (z obliczeń) ISO 15713:2006 Gazy odlotowe Emisja HF (z obliczen) ISO 15713:2006","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"HF emission (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases HF emission (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law ISO 15713:2006","test_object_en":"Waste gases","search_zh":"废气 HF 排放量（计算值） 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 ISO 15713:2006","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"HF 排放量（计算值）"},{"_id":"6a83afc5af14b9c0e7b2069b","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se PN-EN 14385:2025-05 Gazy odlotowe Pobieranie probek do oznaczania stezenia metali: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se PN-EN 14385:2025-05","categories":["materials"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Sampling for determination of metal concentrations: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14385:2025-05","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14385:2025-05","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83afc5af14b9c0e7b2069c","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se (z obliczeń)","reference":"PN-EN 14385:2025-05","norm_bases":["PN-EN 14385:2025-05"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary okresowe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Gazy odlotowe Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se (z obliczeń) PN-EN 14385:2025-05 Gazy odlotowe Emisja As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se (z obliczen) PN-EN 14385:2025-05","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se (calculated)","regulatory_area_en":"Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Waste gases Emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Se (calculated) Periodic measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14385:2025-05","test_object_en":"Waste gases","search_zh":"废气 为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14385:2025-05","test_object_zh":"废气","regulatory_area_zh":"为受监管领域开展的固定源大气排放定期测量\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求"},{"_id":"6a83afc5af14b9c0e7b2069d","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Roczne badanie kontrolne (AST) w zakresie: pyłu, NOx, SO2, O2, CO2 , CO, H2O, HF, HCl","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Roczne badanie kontrolne (AST) w zakresie: pyłu, NOx, SO2, O2, CO2 , CO, H2O, HF, HCl","reference":"PN-EN 14181:2015","norm_bases":["PN-EN 14181:2015"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: pyłu, NOx, SO2, O2, CO2 , CO, H2O, HF, HCl PN-EN 14181:2015 Automatyczne systemy monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie: pylu, NOx, SO2, O2, CO2 , CO, H2O, HF, HCl PN-EN 14181:2015","categories":["other"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Annual surveillance test (AST) for: dust, NOx, SO2, O2, CO2 , CO, H2O, HF, HCl","regulatory_area_en":"Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Automated measuring systems (AMS) Annual surveillance test (AST) for: dust, NOx, SO2, O2, CO2 , CO, H2O, HF, HCl Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14181:2015","test_object_en":"Automated measuring systems (AMS)","regulatory_area_zh":"为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","search_zh":"自动测量系统（AMS） 为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14181:2015","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83afc5af14b9c0e7b2069e","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie: pyłu NOx, SO2, O2, CO2 , CO, H2O, HF, HCl","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kalibracja AMS (QAL2) w zakresie: pyłu NOx, SO2, O2, CO2 , CO, H2O, HF, HCl","reference":"PN-EN 14181:2015","norm_bases":["PN-EN 14181:2015"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: pyłu NOx, SO2, O2, CO2 , CO, H2O, HF, HCl PN-EN 14181:2015 Automatyczne systemy monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie: pylu NOx, SO2, O2, CO2 , CO, H2O, HF, HCl PN-EN 14181:2015","categories":["metrology"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"AMS calibration (QAL2) for: dust NOx, SO2, O2, CO2 , CO, H2O, HF, HCl","regulatory_area_en":"Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Automated measuring systems (AMS) AMS calibration (QAL2) for: dust NOx, SO2, O2, CO2 , CO, H2O, HF, HCl Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law PN-EN 14181:2015","test_object_en":"Automated measuring systems (AMS)","regulatory_area_zh":"为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","search_zh":"自动测量系统（AMS） 为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 PN-EN 14181:2015","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83afc5af14b9c0e7b2069f","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 – 25) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 – 25) g/m3\nMetoda grawimetryczna","reference":"PN-Z-04030-7:1994","norm_bases":["PN-Z-04030-7:1994"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Stężenie pyłu\nZakres (0,001 – 25) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994 Automatyczne systemy monitoringu (AMS) Stezenie pylu\nZakres (0,001 – 25) g/m3\nMetoda grawimetryczna PN-Z-04030-7:1994","categories":["other"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 – 25) g/m3"}],"regulatory_area_en":"Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Automated measuring systems (AMS) Dust concentration Gravimetric method Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-Z-04030-7:1994","technique_en":"Gravimetric method","test_object_en":"Automated measuring systems (AMS)","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 25) g/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-Z-04030-7:1994","technique_zh":"重量法","regulatory_area_zh":"为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83afc5af14b9c0e7b206a0","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Stężenie pyłu","parameters":[{"name":"Zakres","range":"(0,001 – 0,05) g/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłu\nZakres (0,001 – 0,05) g/m3\nMetoda grawimetryczna","reference":"PN-EN 13284-1:2018-02","norm_bases":["PN-EN 13284-1:2018-02"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Stężenie pyłu\nZakres (0,001 – 0,05) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02 Automatyczne systemy monitoringu (AMS) Stezenie pylu\nZakres (0,001 – 0,05) g/m3\nMetoda grawimetryczna PN-EN 13284-1:2018-02","categories":["other"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dust concentration","parameters_en":[{"name":"Range","range":"(0,001 – 0,05) g/m3"}],"regulatory_area_en":"Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Automated measuring systems (AMS) Dust concentration Gravimetric method Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 13284-1:2018-02","technique_en":"Gravimetric method","test_object_en":"Automated measuring systems (AMS)","methodology_zh":"粉尘浓度","parameters_zh":[{"name":"范围","range":"(0,001 – 0,05) g/m3"}],"search_zh":"自动测量系统（AMS） 粉尘浓度 重量法 为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 13284-1:2018-02","technique_zh":"重量法","regulatory_area_zh":"为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83afc5af14b9c0e7b206a1","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Stężenie NOx w przeliczeniu na NO2","parameters":[{"name":"Zakres","range":"(3 – 2050) mg/m3"}],"technique":"Metoda chemiluminescencyjna","techniques":["Metoda chemiluminescencyjna"],"computed":[],"activity":"Stężenie NOx w przeliczeniu na NO2\nZakres (3 – 2050) mg/m3\nMetoda chemiluminescencyjna","reference":"PN-EN 14792:2017-04","norm_bases":["PN-EN 14792:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Stężenie NOx w przeliczeniu na NO2\nZakres (3 – 2050) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04 Automatyczne systemy monitoringu (AMS) Stezenie NOx w przeliczeniu na NO2\nZakres (3 – 2050) mg/m3\nMetoda chemiluminescencyjna PN-EN 14792:2017-04","categories":["other"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NOx concentration calculated as NO2","parameters_en":[{"name":"Range","range":"(3 – 2050) mg/m3"}],"regulatory_area_en":"Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Automated measuring systems (AMS) NOx concentration calculated as NO2 Chemiluminescence method Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 14792:2017-04","technique_en":"Chemiluminescence method","test_object_en":"Automated measuring systems (AMS)","parameters_zh":[{"name":"范围","range":"(3 – 2050) mg/m3"}],"search_zh":"自动测量系统（AMS） 化学发光法 为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 14792:2017-04","regulatory_area_zh":"为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"化学发光法","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83afc5af14b9c0e7b206a2","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Stężenie SO2","parameters":[{"name":"Zakres","range":"(5 – 2000) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie SO2\nZakres (5 – 2000) mg/m3\nMetoda toronowa","reference":"PN-EN 14791: 2017-04","norm_bases":["PN-EN 14791: 2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Stężenie SO2\nZakres (5 – 2000) mg/m3\nMetoda toronowa PN-EN 14791: 2017-04 Automatyczne systemy monitoringu (AMS) Stezenie SO2\nZakres (5 – 2000) mg/m3\nMetoda toronowa PN-EN 14791: 2017-04","categories":["other"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"SO2 concentration","parameters_en":[{"name":"Range","range":"(5 – 2000) mg/m3"}],"regulatory_area_en":"Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Automated measuring systems (AMS) SO2 concentration Thoron method Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 14791: 2017-04","technique_en":"Thoron method","test_object_en":"Automated measuring systems (AMS)","parameters_zh":[{"name":"范围","range":"(5 – 2000) mg/m3"}],"search_zh":"自动测量系统（AMS） SO2 浓度 钍射气法 为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 14791: 2017-04","regulatory_area_zh":"为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"钍射气法","methodology_zh":"SO2 浓度","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83afc5af14b9c0e7b206a3","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Stężenie O2","parameters":[{"name":"Zakres","range":"(2 – 25) %"}],"technique":"Metoda paramagnetyczna","techniques":["Metoda paramagnetyczna"],"computed":[],"activity":"Stężenie O2\nZakres (2 – 25) %\nMetoda paramagnetyczna","reference":"PN-EN 14789:2017-04","norm_bases":["PN-EN 14789:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Stężenie O2\nZakres (2 – 25) %\nMetoda paramagnetyczna PN-EN 14789:2017-04 Automatyczne systemy monitoringu (AMS) Stezenie O2\nZakres (2 – 25) %\nMetoda paramagnetyczna PN-EN 14789:2017-04","categories":["other"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"O2 concentration","parameters_en":[{"name":"Range","range":"(2 – 25) %"}],"regulatory_area_en":"Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Automated measuring systems (AMS) O2 concentration Paramagnetic method Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 14789:2017-04","technique_en":"Paramagnetic method","test_object_en":"Automated measuring systems (AMS)","parameters_zh":[{"name":"范围","range":"(2 – 25) %"}],"search_zh":"自动测量系统（AMS） O2 浓度 顺磁法 为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 14789:2017-04","regulatory_area_zh":"为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","technique_zh":"顺磁法","methodology_zh":"O2 浓度","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83afc5af14b9c0e7b206a4","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Stężenie CO2","parameters":[{"name":"Zakres","range":"(0,5 – 20) %"}],"technique":"Metoda NDIR","techniques":["Metoda NDIR"],"computed":[],"activity":"Stężenie CO2\nZakres (0,5 – 20) %\nMetoda NDIR","reference":"PN-ISO 10396:2001","norm_bases":["PN-ISO 10396:2001"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Stężenie CO2\nZakres (0,5 – 20) %\nMetoda NDIR PN-ISO 10396:2001 Automatyczne systemy monitoringu (AMS) Stezenie CO2\nZakres (0,5 – 20) %\nMetoda NDIR PN-ISO 10396:2001","categories":["other"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO2 concentration","parameters_en":[{"name":"Range","range":"(0,5 – 20) %"}],"regulatory_area_en":"Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Automated measuring systems (AMS) CO2 concentration NDIR method Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-ISO 10396:2001","technique_en":"NDIR method","test_object_en":"Automated measuring systems (AMS)","parameters_zh":[{"name":"范围","range":"(0,5 – 20) %"}],"search_zh":"自动测量系统（AMS） CO2 浓度 非分散红外法（NDIR） 为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-ISO 10396:2001","regulatory_area_zh":"为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"CO2 浓度","test_object_zh":"自动测量系统（AMS）","technique_zh":"非分散红外法（NDIR）"},{"_id":"6a83afc5af14b9c0e7b206a5","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Stężenie CO","parameters":[{"name":"Zakres","range":"(4 – 625) mg/m3"}],"technique":"Metoda NDIR","techniques":["Metoda NDIR"],"computed":[],"activity":"Stężenie CO\nZakres (4 – 625) mg/m3\nMetoda NDIR","reference":"PN-EN 15058:2017-04","norm_bases":["PN-EN 15058:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Stężenie CO\nZakres (4 – 625) mg/m3\nMetoda NDIR PN-EN 15058:2017-04 Automatyczne systemy monitoringu (AMS) Stezenie CO\nZakres (4 – 625) mg/m3\nMetoda NDIR PN-EN 15058:2017-04","categories":["other"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"CO concentration","parameters_en":[{"name":"Range","range":"(4 – 625) mg/m3"}],"regulatory_area_en":"Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Automated measuring systems (AMS) CO concentration NDIR method Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 15058:2017-04","technique_en":"NDIR method","test_object_en":"Automated measuring systems (AMS)","parameters_zh":[{"name":"范围","range":"(4 – 625) mg/m3"}],"search_zh":"自动测量系统（AMS） CO 浓度 非分散红外法（NDIR） 为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 15058:2017-04","regulatory_area_zh":"为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"CO 浓度","test_object_zh":"自动测量系统（AMS）","technique_zh":"非分散红外法（NDIR）"},{"_id":"6a83afc5af14b9c0e7b206a6","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Stężenie H2O","parameters":[{"name":"Zakres","range":"(29 – 250) g/m3"},{"name":"Zakres","range":"(4 – 40) %"}],"technique":"Metoda kondensacyjno-adsorpcyjna","techniques":["Metoda kondensacyjno-adsorpcyjna"],"computed":[],"activity":"Stężenie H2O\nZakres:\nZakres (29 – 250) g/m3\nZakres (4 – 40) %\nMetoda kondensacyjno-adsorpcyjna","reference":"PN-EN 14790:2017-04","norm_bases":["PN-EN 14790:2017-04"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Stężenie H2O\nZakres:\nZakres (29 – 250) g/m3\nZakres (4 – 40) %\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04 Automatyczne systemy monitoringu (AMS) Stezenie H2O\nZakres:\nZakres (29 – 250) g/m3\nZakres (4 – 40) %\nMetoda kondensacyjno-adsorpcyjna PN-EN 14790:2017-04","categories":["other"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"H2O concentration","parameters_en":[{"name":"Range","range":"(29 – 250) g/m3"},{"name":"Range","range":"(4 – 40) %"}],"regulatory_area_en":"Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Automated measuring systems (AMS) H2O concentration Condensation-adsorption method Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range Range PN-EN 14790:2017-04","technique_en":"Condensation-adsorption method","test_object_en":"Automated measuring systems (AMS)","parameters_zh":[{"name":"范围","range":"(29 – 250) g/m3"},{"name":"范围","range":"(4 – 40) %"}],"search_zh":"自动测量系统（AMS） 冷凝-吸附法 为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 范围 PN-EN 14790:2017-04","regulatory_area_zh":"为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","test_object_zh":"自动测量系统（AMS）","technique_zh":"冷凝-吸附法"},{"_id":"6a83afc5af14b9c0e7b206a7","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Stężenie chlorowodoru","parameters":[{"name":"Zakres","range":"(0,8 – 350) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chlorowodoru\nZakres (0,8 – 350) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN 1911:2011","norm_bases":["PN-EN 1911:2011"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Stężenie chlorowodoru\nZakres (0,8 – 350) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011 Automatyczne systemy monitoringu (AMS) Stezenie chlorowodoru\nZakres (0,8 – 350) mg/m3\nMetoda spektrofotometryczna PN-EN 1911:2011","categories":["other"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen chloride concentration","parameters_en":[{"name":"Range","range":"(0,8 – 350) mg/m3"}],"regulatory_area_en":"Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Automated measuring systems (AMS) Hydrogen chloride concentration Spectrophotometric method Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range PN-EN 1911:2011","technique_en":"Spectrophotometric method","test_object_en":"Automated measuring systems (AMS)","parameters_zh":[{"name":"范围","range":"(0,8 – 350) mg/m3"}],"search_zh":"自动测量系统（AMS） 氯化氢浓度 分光光度法 为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 PN-EN 1911:2011","technique_zh":"分光光度法","regulatory_area_zh":"为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","methodology_zh":"氯化氢浓度","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83afc5af14b9c0e7b206a8","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Stężenie fluorowodoru","parameters":[{"name":"Zakres","range":"(0,2 – 20) mg/m3"}],"technique":"Metoda potencjometryczna z zastosowaniem elektrody jonoselektywnej","techniques":["Metoda potencjometryczna z zastosowaniem elektrody jonoselektywnej"],"computed":[],"activity":"Stężenie fluorowodoru\nZakres (0,2 – 20) mg/m3\nMetoda potencjometryczna z zastosowaniem elektrody jonoselektywnej","reference":"ISO 15713:2006","norm_bases":["ISO 15713:2006"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":"Pomiary ciągłe emisji do powietrza ze źródeł stacjonarnych wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań przepisów aktów wykonawczych do ustawy z dnia 27 kwietnia 2001 r. Prawo ochrony środowiska","flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Stężenie fluorowodoru\nZakres (0,2 – 20) mg/m3\nMetoda potencjometryczna z zastosowaniem elektrody jonoselektywnej ISO 15713:2006 Automatyczne systemy monitoringu (AMS) Stezenie fluorowodoru\nZakres (0,2 – 20) mg/m3\nMetoda potencjometryczna z zastosowaniem elektrody jonoselektywnej ISO 15713:2006","categories":["other"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen fluoride concentration","parameters_en":[{"name":"Range","range":"(0,2 – 20) mg/m3"}],"regulatory_area_en":"Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law","search_en":"Automated measuring systems (AMS) Hydrogen fluoride concentration Potentiometric method using an ion-selective electrode Continuous measurements of emissions to air from stationary sources carried out for the purposes of the regulated area\nThe competence of the laboratory has been confirmed taking into account the applicable requirements of the implementing acts to the Act of 27 April 2001 Environmental Protection Law Range ISO 15713:2006","technique_en":"Potentiometric method using an ion-selective electrode","test_object_en":"Automated measuring systems (AMS)","parameters_zh":[{"name":"范围","range":"(0,2 – 20) mg/m3"}],"search_zh":"自动测量系统（AMS） 氟化氢浓度 为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求 范围 ISO 15713:2006","regulatory_area_zh":"为受管制领域目的开展的固定源大气排放连续监测\n已确认实验室的能力，并考虑了 2001 年 4 月 27 日《环境保护法》实施细则中的适用要求","test_object_zh":"自动测量系统（AMS）","methodology_zh":"氟化氢浓度"},{"_id":"6a83afc5af14b9c0e7b206a9","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia amoniaku","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia amoniaku","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia amoniaku PN-EN ISO 21877:2020-03 Gazy odlotowe Pobieranie probek do oznaczania stezenia amoniaku PN-EN ISO 21877:2020-03","categories":["other"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of ammonia concentration","search_en":"Waste gases Sampling for determination of ammonia concentration PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 氨浓度测定采样 PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"氨浓度测定采样"},{"_id":"6a83afc5af14b9c0e7b206aa","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie amoniaku","parameters":[{"name":"Zakres","range":"(0,2 – 20) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie amoniaku\nZakres (0,2 – 20) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie amoniaku\nZakres (0,2 – 20) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Gazy odlotowe Stezenie amoniaku\nZakres (0,2 – 20) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration","parameters_en":[{"name":"Range","range":"(0,2 – 20) mg/m3"}],"search_en":"Waste gases Ammonia concentration Spectrophotometric method Range PN-EN ISO 21877:2020-03","technique_en":"Spectrophotometric method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(0,2 – 20) mg/m3"}],"search_zh":"废气 氨浓度 分光光度法 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","test_object_zh":"废气","methodology_zh":"氨浓度"},{"_id":"6a83afc5af14b9c0e7b206ab","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja NH3 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja NH3 (z obliczeń)","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja NH3 (z obliczeń) PN-EN ISO 21877:2020-03 Gazy odlotowe Emisja NH3 (z obliczen) PN-EN ISO 21877:2020-03","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"NH3 emission (calculated)","search_en":"Waste gases NH3 emission (calculated) PN-EN ISO 21877:2020-03","test_object_en":"Waste gases","search_zh":"废气 NH3 排放（由计算得出） PN-EN ISO 21877:2020-03","test_object_zh":"废气","methodology_zh":"NH3 排放（由计算得出）"},{"_id":"6a83afc5af14b9c0e7b206ac","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Pobieranie próbek do oznaczania stężenia kwasu siarkowego, w tym trójtlenku siarki","parameters":[],"technique":"Metoda aspiracyjna z zastosowaniem roztworów pochłaniających","techniques":["Metoda aspiracyjna z zastosowaniem roztworów pochłaniających"],"computed":[],"activity":"Pobieranie próbek do oznaczania stężenia kwasu siarkowego, w tym trójtlenku siarki\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających","reference":"SE.PB.01 edycja nr 1 z 10.03.2021 r.","norm_bases":["SE.PB.01 edycja nr 1 z 10.03.2021 r."],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Pobieranie próbek do oznaczania stężenia kwasu siarkowego, w tym trójtlenku siarki\nMetoda aspiracyjna z zastosowaniem roztworów pochłaniających SE.PB.01 edycja nr 1 z 10.03.2021 r. Gazy odlotowe Pobieranie probek do oznaczania stezenia kwasu siarkowego, w tym trojtlenku siarki\nMetoda aspiracyjna z zastosowaniem roztworow pochlaniajacych SE.PB.01 edycja nr 1 z 10.03.2021 r.","categories":["other"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for determination of the concentration of sulfuric acid, including sulfur trioxide","search_en":"Waste gases Sampling for determination of the concentration of sulfuric acid, including sulfur trioxide Aspiration method using absorbing solutions SE.PB.01 edycja nr 1 z 10.03.2021 r.","technique_en":"Aspiration method using absorbing solutions","test_object_en":"Waste gases","search_zh":"废气 采用吸收液的抽气法 SE.PB.01 edycja nr 1 z 10.03.2021 r.","test_object_zh":"废气","technique_zh":"采用吸收液的抽气法"},{"_id":"6a83afc5af14b9c0e7b206ad","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Stężenie kwasu siarkowego, w tym trójtlenku siarki","parameters":[{"name":"Zakres","range":"(2 – 50) mg/m3"}],"technique":"Metoda toronowa","techniques":["Metoda toronowa"],"computed":[],"activity":"Stężenie kwasu siarkowego, w tym trójtlenku siarki\nZakres (2 – 50) mg/m3\nMetoda toronowa","reference":"SE.PB.01 edycja nr 1 z 10.03.2021 r.","norm_bases":["SE.PB.01 edycja nr 1 z 10.03.2021 r."],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Stężenie kwasu siarkowego, w tym trójtlenku siarki\nZakres (2 – 50) mg/m3\nMetoda toronowa SE.PB.01 edycja nr 1 z 10.03.2021 r. Gazy odlotowe Stezenie kwasu siarkowego, w tym trojtlenku siarki\nZakres (2 – 50) mg/m3\nMetoda toronowa SE.PB.01 edycja nr 1 z 10.03.2021 r.","categories":["other"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulphuric acid concentration, including sulphur trioxide","parameters_en":[{"name":"Range","range":"(2 – 50) mg/m3"}],"search_en":"Waste gases Sulphuric acid concentration, including sulphur trioxide Thoron method Range SE.PB.01 edycja nr 1 z 10.03.2021 r.","technique_en":"Thoron method","test_object_en":"Waste gases","parameters_zh":[{"name":"范围","range":"(2 – 50) mg/m3"}],"search_zh":"废气 钍射气法 范围 SE.PB.01 edycja nr 1 z 10.03.2021 r.","test_object_zh":"废气","technique_zh":"钍射气法"},{"_id":"6a83afc5af14b9c0e7b206ae","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Gazy odlotowe","methodology":"Emisja H2SO4 i SO3 (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Emisja H2SO4 i SO3 (z obliczeń)","reference":"SE.PB.01 edycja nr 1 z 10.03.2021 r.","norm_bases":["SE.PB.01 edycja nr 1 z 10.03.2021 r."],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Gazy odlotowe Emisja H2SO4 i SO3 (z obliczeń) SE.PB.01 edycja nr 1 z 10.03.2021 r. Gazy odlotowe Emisja H2SO4 i SO3 (z obliczen) SE.PB.01 edycja nr 1 z 10.03.2021 r.","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Emission of H2SO4 and SO3 (calculated)","search_en":"Waste gases Emission of H2SO4 and SO3 (calculated) SE.PB.01 edycja nr 1 z 10.03.2021 r.","test_object_en":"Waste gases","search_zh":"废气 SE.PB.01 edycja nr 1 z 10.03.2021 r.","test_object_zh":"废气"},{"_id":"6a83afc5af14b9c0e7b206af","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Roczne badanie kontrolne (AST) w zakresie NH3","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Roczne badanie kontrolne (AST) w zakresie NH3","reference":"PN-EN 14181:2015","norm_bases":["PN-EN 14181:2015"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie NH3 PN-EN 14181:2015 Automatyczne systemy monitoringu (AMS) Roczne badanie kontrolne (AST) w zakresie NH3 PN-EN 14181:2015","categories":["other"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Annual surveillance test (AST) for NH3","search_en":"Automated measuring systems (AMS) Annual surveillance test (AST) for NH3 PN-EN 14181:2015","test_object_en":"Automated measuring systems (AMS)","search_zh":"自动测量系统（AMS） PN-EN 14181:2015","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83afc5af14b9c0e7b206b0","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Kalibracja AMS (QAL2) w zakresie NH3","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Kalibracja AMS (QAL2) w zakresie NH3","reference":"PN-EN 14181:2015","norm_bases":["PN-EN 14181:2015"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie NH3 PN-EN 14181:2015 Automatyczne systemy monitoringu (AMS) Kalibracja AMS (QAL2) w zakresie NH3 PN-EN 14181:2015","categories":["metrology"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"AMS calibration (QAL2) for NH3","search_en":"Automated measuring systems (AMS) AMS calibration (QAL2) for NH3 PN-EN 14181:2015","test_object_en":"Automated measuring systems (AMS)","search_zh":"自动测量系统（AMS） PN-EN 14181:2015","test_object_zh":"自动测量系统（AMS）"},{"_id":"6a83afc5af14b9c0e7b206b1","lab_id":"69ad52a3de79e566650fb3d4","country":"PL","accr_number":"AB 761","accr_body":"PCA","test_object":"Automatyczne systemy monitoringu (AMS)","methodology":"Stężenie amoniaku","parameters":[{"name":"Zakres","range":"(0,2 – 20) mg/m3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie amoniaku\nZakres (0,2 – 20) mg/m3\nMetoda spektrofotometryczna","reference":"PN-EN ISO 21877:2020-03","norm_bases":["PN-EN ISO 21877:2020-03"],"lab_section":"Laboratorium; Sekcja Pomiarów Emisyjnych; Jadzi Andrzejewskiej 5, 92-550 Łódź","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Automatyczne systemy monitoringu (AMS) Stężenie amoniaku\nZakres (0,2 – 20) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03 Automatyczne systemy monitoringu (AMS) Stezenie amoniaku\nZakres (0,2 – 20) mg/m3\nMetoda spektrofotometryczna PN-EN ISO 21877:2020-03","categories":["other"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration","parameters_en":[{"name":"Range","range":"(0,2 – 20) mg/m3"}],"search_en":"Automated measuring systems (AMS) Ammonia concentration Spectrophotometric method Range PN-EN ISO 21877:2020-03","technique_en":"Spectrophotometric method","test_object_en":"Automated measuring systems (AMS)","parameters_zh":[{"name":"范围","range":"(0,2 – 20) mg/m3"}],"search_zh":"自动测量系统（AMS） 氨浓度 分光光度法 范围 PN-EN ISO 21877:2020-03","technique_zh":"分光光度法","methodology_zh":"氨浓度","test_object_zh":"自动测量系统（AMS）"}],"has_pdf":true}