🇵🇱 ELFEKO S.A. PL
EnvironmentElectronics & EMC
ELFEKO S.A. is a laboratory accredited by PCA under number AB 760 (Gdynia, Poland). Its accreditation scope covers 4 test methods in the following areas: Environment, Electronics & EMC. Test objects include: Environment – electromagnetic field in the vicinity of electric pow…, Workplace environment – electromagnetic field in the work space ori…. Most frequently used techniques: Direct measurement method.
At a glance
- Accreditation number: PCA AB 760
- Methods in scope: 4
- Types of test objects: 2
- Techniques used: 1
- City: Gdynia, Poland
- Accreditation number
- AB 760
- Accreditation body
- PCA
- Address
- LABORATORIUM BADAWCZE ELFEKO S.A., ul. Hutnicza 20A, 81-061 Gdynia
- City
- Gdynia, Poland
What this laboratory tests (2)
- Environment – electromagnetic field in the vicinity of electric power substations and power lines — 2 methods
- Workplace environment – electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry — 2 methods
Analytical techniques used (1)
- Direct measurement method — 4 methods
Accreditation scope — test methods (4)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Electric field strength: in the frequency range 50 Hz Range 1,0 V/m – 30 kV/m |
Direct measurement method | Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 2 | Environment – electromagnetic field in the vicinity of electric power substations and power lines | Magnetic field strength: in the frequency range 50 Hz Range 0,4 A/m – 8 kA/m |
Direct measurement method | Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 3 | Workplace environment – electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry | Electric field strength: in the frequency range 50 Hz Range 1 V/m – 30 kV/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 | |
| 4 | Workplace environment – electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry | Magnetic field strength: in the frequency range 50 Hz Range 0,4 A/m – 8 kA/m |
Direct measurement method | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 | |
Reference standards (2)
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150
Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)