{"lab":{"_id":"69ad52a3de79e566650fb3d2","accr_number":"AB 760","country":"PL","accr_body":"PCA","address":"LABORATORIUM BADAWCZE ELFEKO S.A., ul. Hutnicza 20A, 81-061 Gdynia","categories":["environment"],"city":"Gdynia","imported_at":"2026-03-08T10:42:43.265Z","methods_count":4,"name":"ELFEKO S.A.","parse_status":"parsed","parse_version":2,"pdf_files":["AB_760.pdf"],"scope_summary":"","search_text":"elfeko s.a. laboratorium badawcze elfeko s.a., ul. hutnicza 20a, 81-061 gdynia environment metrology pharma electronics materials other","status":"active","updated_at":"2026-03-08T14:51:39.014Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:39.014Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20760,podmiot.html","fields_of_testing":[{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) - środowisko pracy (czynniki szkodliwe – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful factors – electromagnetic field)"},{"codes":"G/34","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko ogólne (czynniki fizyczne – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – general environment (physical factors - electromagnetic field)"}],"issue":{"no":"17","date":"10.07.2024"},"parse_date":"2026-07-20T07:09:49.840Z","parse_source":"script-pdfplumber","map_coord":[54.548778,18.47034],"map_geo":"nominatim-street","has_en":true,"category_counts":{"environment":4},"category_scores":{"environment":4},"has_zh":true},"methods":[{"_id":"6a5dc9bdf1c10c8ce825e7bd","lab_id":"69ad52a3de79e566650fb3d2","country":"PL","accr_number":"AB 760","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"1,0 V/m – 30 kV/m"}],"parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"1,0 V/m – 30 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 1,0 V/m – 30 kV/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 1,0 V/m – 30 kV/m\nMetoda pomiarowa bezpośrednia Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 1,0 V/m – 30 kV/m\nMetoda pomiarowa bezposrednia Zalacznik do rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Electric field strength: Direct measurement method in the frequency range 50 Hz Range Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"1,0 V/m – 30 kV/m"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 电场强度： 直接测量法 频率范围 50 Hz 范围 Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a5dc9bdf1c10c8ce825e7be","lab_id":"69ad52a3de79e566650fb3d2","country":"PL","accr_number":"AB 760","accr_body":"PCA","test_object":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych","test_object_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"0,4 A/m – 8 kA/m"}],"parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"0,4 A/m – 8 kA/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 0,4 A/m – 8 kA/m\nMetoda pomiarowa bezpośrednia","reference":"Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","norm_bases":["Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 0,4 A/m – 8 kA/m\nMetoda pomiarowa bezpośrednia Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) Srodowisko – pole elektromagnetyczne w otoczeniu stacji elektroenergetycznych i linii elektroenergetycznych Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 0,4 A/m – 8 kA/m\nMetoda pomiarowa bezposrednia Zalacznik do rozporzadzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","categories":["environment"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Environment – electromagnetic field in the vicinity of electric power substations and power lines Magnetic field strength: Direct measurement method in the frequency range 50 Hz Range Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"0,4 A/m – 8 kA/m"}],"search_zh":"环境 — 变电站与输电线路周围的电磁场 磁场强度： 直接测量法 频率范围 50 Hz 范围 Załącznik do rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)","technique_zh":"直接测量法","test_object_zh":"环境 — 变电站与输电线路周围的电磁场"},{"_id":"6a5dc9bdf1c10c8ce825e7bf","lab_id":"69ad52a3de79e566650fb3d2","country":"PL","accr_number":"AB 760","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","test_object_en":"Workplace environment – electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry","methodology":"Natężenie pola elektrycznego:","methodology_en":"Electric field strength:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"1 V/m – 30 kV/m"}],"parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"1 V/m – 30 kV/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 1 V/m – 30 kV/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola elektrycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 1 V/m – 30 kV/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola elektrycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 1 V/m – 30 kV/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91–150","categories":["environment"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry Electric field strength: Direct measurement method in the frequency range 50 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","methodology_zh":"电场强度：","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"1 V/m – 30 kV/m"}],"search_zh":"电场强度： 直接测量法 频率范围 50 Hz 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","technique_zh":"直接测量法"},{"_id":"6a5dc9bdf1c10c8ce825e7c0","lab_id":"69ad52a3de79e566650fb3d2","country":"PL","accr_number":"AB 760","accr_body":"PCA","test_object":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce","test_object_en":"Workplace environment – electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry","methodology":"Natężenie pola magnetycznego:","methodology_en":"Magnetic field strength:","parameters":[{"name":"w zakresie częstotliwości 50 Hz"},{"name":"Zakres","range":"0,4 A/m – 8 kA/m"}],"parameters_en":[{"name":"in the frequency range 50 Hz"},{"name":"Range","range":"0,4 A/m – 8 kA/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"technique_en":"Direct measurement method","computed":[],"computed_en":[],"activity":"Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 0,4 A/m – 8 kA/m\nMetoda pomiarowa bezpośrednia","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Środowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzące od systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce Natężenie pola magnetycznego:\nZakres:\nw zakresie częstotliwości 50 Hz\nZakres 0,4 A/m – 8 kA/m\nMetoda pomiarowa bezpośrednia Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150 Srodowisko pracy – pole elektromagnetyczne w przestrzeni pracy pochodzace od systemow elektroenergetycznych i elektrycznych instalacji zasilajacych pradu przemiennego w energetyce Natezenie pola magnetycznego:\nZakres:\nw zakresie czestotliwosci 50 Hz\nZakres 0,4 A/m – 8 kA/m\nMetoda pomiarowa bezposrednia Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 91–150","categories":["environment"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Workplace environment – electromagnetic field in the work space originating from power systems and AC electrical supply installations in the power industry Magnetic field strength: Direct measurement method in the frequency range 50 Hz Range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","methodology_zh":"磁场强度：","parameters_zh":[{"name":"频率范围 50 Hz"},{"name":"范围","range":"0,4 A/m – 8 kA/m"}],"search_zh":"磁场强度： 直接测量法 频率范围 50 Hz 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 91–150","technique_zh":"直接测量法"}],"has_pdf":true}