🇵🇱 WODOCIĄGI I KANALIZACJA Sp. z o.o. PL
Water & wastewaterMicrobiology
WODOCIĄGI I KANALIZACJA Sp. z o.o. is a laboratory accredited by PCA under number AB 756 (Dzierżoniów, Poland). Its accreditation scope covers 43 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Wastewater, Water, Wastewater, Water. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 756
- Methods in scope: 43
- Types of test objects: 6
- Techniques used: 13
- City: Dzierżoniów, Poland
- Accreditation number
- AB 756
- Accreditation body
- PCA
- Address
- ul. Kilińskiego 25 A, 58-200 Dzierżoniów, DZIAŁ LABORATORIUM, ul. Relaksowa 5, 58-200 Dzierżoniów
- City
- Dzierżoniów, Poland
What this laboratory tests (6)
- Water, Water intended for human consumption — 26 methods
- Wastewater — 8 methods
- Water, Wastewater — 5 methods
- Water — 2 methods
- Water intended for human consumption — 1 method
- Water, Water intended for human consumption, Wastewater — 1 method
Analytical techniques used (13)
- Spectrophotometric method — 14 methods
- Membrane filtration method — 5 methods
- Titrimetric method — 5 methods
- Electrochemical method — 3 methods
- MPN method — 3 methods
- Plate method, pour plate — 2 methods
- Potentiometric method — 2 methods
- Turbidimetric method — 2 methods
- Conductometric method — 1 method
- Gravimetric method — 1 method
- Manual method; Automatic method — 1 method
- metoda (z obliczeń) — 1 method
- Nephelometric method — 1 method
Laboratory locations
- DZIAŁ LABORATORIUM — ul. Relaksowa 5
Accreditation scope — test methods (43)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Dział laboratorium | |||||
| 1 | Wastewater | Sampling for chemical and physical testing. | Manual method; Automatic method | PN- ISO 5667-10:2021-11 | |
| 2 | Wastewater | pH Range 4,0 – 10,0 Regulated area: + Badania wykonywane w siedzibie i poza siedzibą laboratorium |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 3 | Wastewater | Ammonium nitrogen concentration Range (0,10 – 110) mg/l |
Spectrophotometric method | PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001 | |
| 4 | Wastewater | Nitrate nitrogen concentration Range (0,50 – 25,0) mg/l |
Spectrophotometric method | PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001 | |
| 5 | Wastewater | Total phosphorus concentration Range (0,05 – 45) mg/l |
Spectrophotometric method | PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001 | |
| 6 | Wastewater | Chloride concentration Range (2,0 – 1000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 7 | Wastewater | Sulfate concentration Range (20 – 1000) mg/l |
Turbidimetric method | PL-B-05 wydanie 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051 | |
| 8 | Wastewater | Chemical oxygen demand COD Range (4,00 – 5000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 9 | Water, Water intended for human consumption, Wastewater | Electrical conductivity Range (100 – 3000) μS/cm Regulated area: + Badania wykonywane w siedzibie i poza siedzibą laboratorium |
Conductometric method | PN-EN 27888:1999 | |
| 10 | Water, Wastewater | Total nitrogen concentration Range (0,50 – 150) mg/l |
Spectrophotometric method | PL-B-10 wydanie 3 z dnia 19.05.2016 r. | na podstawie testu Merck nr 1006130001 i 1147630001 | |
| 11 | Water, Wastewater | Total suspended solids (TSS) Range (2,0 – 5000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 12 | Water, Wastewater | Dissolved oxygen concentration Range (1,0 – 15,0) mg/l O2 |
Electrochemical method | PN-EN ISO 5814:2013-04 | |
| 13 | Water, Wastewater | Biochemical oxygen demand BOD5 Range (3,0 – 2000) mg/l O2 |
Electrochemical method | PN-EN ISO 5815-1:2019:12 | |
| 14 | Water, Wastewater | Biochemical oxygen demand BOD5 Range (1,0 – 6,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 15 | Water, Water intended for human consumption | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 | ||
| 16 | Water, Water intended for human consumption | Turbidity Range (0,10 – 100) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 17 | Water, Water intended for human consumption | Free chlorine concentration Range (0,040 – 2,00) mg/l Regulated area: + Badania wykonywane w siedzibie i poza siedzibą laboratorium |
Spectrophotometric method | PL-B-12 wydanie 2 z dnia 02.06.2017 r. | |
| 18 | Water, Water intended for human consumption | Permanganate index Range (0,50 – 10) mg/l |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 19 | Water, Water intended for human consumption | pH Range 4,0 – 10,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 20 | Water, Water intended for human consumption | Ammonium ion concentration Range (0,040 – 0,60) mg/l |
Spectrophotometric method | PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001 | |
| 21 | Water, Water intended for human consumption | Nitrate concentration Range (2,20– 70,0) mg/l |
Spectrophotometric method | PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001 | |
| 22 | Water, Water intended for human consumption | Phosphate concentration Range (0,10 – 3,00) mg/l |
Spectrophotometric method | PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001 | |
| 23 | Water, Water intended for human consumption | Total hardness (Total concentration of calcium and magnesium) Range (5,0 – 1000 mg) mg/l |
Titrimetric method | PN-ISO 6059:1999 | |
| 24 | Water, Water intended for human consumption | Calcium concentration Range (2,0 – 200) mg/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 25 | Water, Water intended for human consumption | Magnesium concentration | metoda (z obliczeń) | PN-C-04554-4:1999, Załącznik A | |
| 26 | Water, Water intended for human consumption | Total iron concentration Range (0,030 – 5,0) mg/l |
Spectrophotometric method | PL-B-01 wydanie 5 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147610001 | |
| 27 | Water, Water intended for human consumption | Manganese concentration Range (0,010 – 2,00) mg/l |
Spectrophotometric method | PL-B-16 wydanie 1 z dnia 12.05.2014 r. | na podstawie testu HACH LANGE nr 032 | |
| 28 | Water, Water intended for human consumption | Aluminium concentration Range (0,060 – 0,70) mg/l |
Spectrophotometric method | PL-B-09 wydanie 2 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1148250001 | |
| 29 | Water, Water intended for human consumption | Chloride concentration Range (2,00– 250) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 30 | Water, Water intended for human consumption | Sulfate concentration Range (10 – 250) mg/l |
Turbidimetric method | PL-B-05 wyd. 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051 | |
| 31 | Water, Water intended for human consumption | Colour Range (4 – 100) mg/l Pt/Co |
Spectrophotometric method | PN-EN ISO 7887:2012 metoda C+Ap1:2015-06 | |
| 32 | Water | Chemical oxygen demand COD Range (4,00 – 150) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 33 | Water, Water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007, z wyłączeniem punktów 4.4.3, 4.4.4.1, 4.4.5, 4.4.6 | ||
| 34 | Water, Water intended for human consumption | Total microorganism count at a temperature of 22°C | Plate method, pour plate | PN-EN ISO 6222:2004 | |
| 35 | Water, Water intended for human consumption | Total microorganism count at 36°C | Plate method, pour plate | PN-EN ISO 6222:2004 | |
| 36 | Water, Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 37 | Water, Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+A1:2017-04 | |
| 38 | Water, Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12+A1:2017-04 | |
| 39 | Water, Water intended for human consumption | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 40 | Water, Water intended for human consumption | Most probable number of Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 41 | Water, Water intended for human consumption | Clostridium perfringens count (including spores) | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 42 | Water | Count of bacteria of the genus Legionella, Matrix B, Procedure 7 (medium C-GVPC) | Membrane filtration method | PN-EN ISO 11731:2017-08+Ap1:2019-12 | |
| 43 | Water intended for human consumption | Most probable number of Pseudomonas aeruginosa | MPN method | PN-EN ISO 16266-2:2022-04 | |
Reference standards (42)
PL-B-01 wydanie 5 z dnia 04.05.2010 r.
PL-B-04 wydanie 5 z dnia 01.06.2018 r.
PL-B-05 wyd. 5 z dnia 22.05.2023 r.
PL-B-05 wydanie 5 z dnia 22.05.2023 r.
PL-B-06 wydanie 3 z dnia 04.05.2010 r.
PL-B-07 wydanie 3 z dnia 04.05.2010 r.
PL-B-09 wydanie 2 z dnia 04.05.2010 r.
PL-B-10 wydanie 3 z dnia 19.05.2016 r.
PL-B-12 wydanie 2 z dnia 02.06.2017 r.
PL-B-16 wydanie 1 z dnia 12.05.2014 r.
PN- ISO 5667-10:2021-11
PN-C-04554-4:1999, Załącznik A
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08+Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 16266-2:2022-04
PN-EN ISO 19458:2007, z wyłączeniem punktów 4.4.3, 4.4.4.1, 4.4.5, 4.4.6
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019:12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C+Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12+A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 9297:1994
na podstawie testu HACH LANGE nr 032
na podstawie testu Merck nr 1006130001 i 1147630001
na podstawie testu Merck nr 1097130001
na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051
na podstawie testu Merck nr 1147520001
na podstawie testu Merck nr 1147610001
na podstawie testu Merck nr 1148250001
na podstawie testu Merck nr 1148480001