🇵🇱 WODOCIĄGI I KANALIZACJA Sp. z o.o. PL

PCA AB 756 • Dzierżoniów, Poland • 43 methods

Water & wastewaterMicrobiology

WODOCIĄGI I KANALIZACJA Sp. z o.o. is a laboratory accredited by PCA under number AB 756 (Dzierżoniów, Poland). Its accreditation scope covers 43 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Wastewater, Water, Wastewater, Water. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 756
  • Methods in scope: 43
  • Types of test objects: 6
  • Techniques used: 13
  • City: Dzierżoniów, Poland
Accreditation number
AB 756
Accreditation body
PCA
Address
ul. Kilińskiego 25 A, 58-200 Dzierżoniów, DZIAŁ LABORATORIUM, ul. Relaksowa 5, 58-200 Dzierżoniów
City
Dzierżoniów, Poland

What this laboratory tests (6)

Analytical techniques used (13)

Laboratory locations

Accreditation scope — test methods (43)

No. Test object Methodology / Parameters Technique Reference document
Dział laboratorium
1 Wastewater Sampling for chemical and physical testing. Manual method; Automatic method PN- ISO 5667-10:2021-11
2 Wastewater pH
Range 4,0 – 10,0
Regulated area: + Badania wykonywane w siedzibie i poza siedzibą laboratorium
Potentiometric method PN-EN ISO 10523:2012
3 Wastewater Ammonium nitrogen concentration
Range (0,10 – 110) mg/l
Spectrophotometric method PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001
4 Wastewater Nitrate nitrogen concentration
Range (0,50 – 25,0) mg/l
Spectrophotometric method PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001
5 Wastewater Total phosphorus concentration
Range (0,05 – 45) mg/l
Spectrophotometric method PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001
6 Wastewater Chloride concentration
Range (2,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
7 Wastewater Sulfate concentration
Range (20 – 1000) mg/l
Turbidimetric method PL-B-05 wydanie 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051
8 Wastewater Chemical oxygen demand
COD Range (4,00 – 5000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
9 Water, Water intended for human consumption, Wastewater Electrical conductivity
Range (100 – 3000) μS/cm
Regulated area: + Badania wykonywane w siedzibie i poza siedzibą laboratorium
Conductometric method PN-EN 27888:1999
10 Water, Wastewater Total nitrogen concentration
Range (0,50 – 150) mg/l
Spectrophotometric method PL-B-10 wydanie 3 z dnia 19.05.2016 r. | na podstawie testu Merck nr 1006130001 i 1147630001
11 Water, Wastewater Total suspended solids (TSS)
Range (2,0 – 5000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
12 Water, Wastewater Dissolved oxygen concentration
Range (1,0 – 15,0) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04
13 Water, Wastewater Biochemical oxygen demand
BOD5 Range (3,0 – 2000) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019:12
14 Water, Wastewater Biochemical oxygen demand
BOD5 Range (1,0 – 6,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
15 Water, Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
16 Water, Water intended for human consumption Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
17 Water, Water intended for human consumption Free chlorine concentration
Range (0,040 – 2,00) mg/l
Regulated area: + Badania wykonywane w siedzibie i poza siedzibą laboratorium
Spectrophotometric method PL-B-12 wydanie 2 z dnia 02.06.2017 r.
18 Water, Water intended for human consumption Permanganate index
Range (0,50 – 10) mg/l
Titrimetric method PN-EN ISO 8467:2001
19 Water, Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
20 Water, Water intended for human consumption Ammonium ion concentration
Range (0,040 – 0,60) mg/l
Spectrophotometric method PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001
21 Water, Water intended for human consumption Nitrate concentration
Range (2,20– 70,0) mg/l
Spectrophotometric method PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001
22 Water, Water intended for human consumption Phosphate concentration
Range (0,10 – 3,00) mg/l
Spectrophotometric method PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001
23 Water, Water intended for human consumption Total hardness (Total concentration of calcium and magnesium)
Range (5,0 – 1000 mg) mg/l
Titrimetric method PN-ISO 6059:1999
24 Water, Water intended for human consumption Calcium concentration
Range (2,0 – 200) mg/l
Titrimetric method PN-ISO 6058:1999
25 Water, Water intended for human consumption Magnesium concentration metoda (z obliczeń) PN-C-04554-4:1999, Załącznik A
26 Water, Water intended for human consumption Total iron concentration
Range (0,030 – 5,0) mg/l
Spectrophotometric method PL-B-01 wydanie 5 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147610001
27 Water, Water intended for human consumption Manganese concentration
Range (0,010 – 2,00) mg/l
Spectrophotometric method PL-B-16 wydanie 1 z dnia 12.05.2014 r. | na podstawie testu HACH LANGE nr 032
28 Water, Water intended for human consumption Aluminium concentration
Range (0,060 – 0,70) mg/l
Spectrophotometric method PL-B-09 wydanie 2 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1148250001
29 Water, Water intended for human consumption Chloride concentration
Range (2,00– 250) mg/l
Titrimetric method PN-ISO 9297:1994
30 Water, Water intended for human consumption Sulfate concentration
Range (10 – 250) mg/l
Turbidimetric method PL-B-05 wyd. 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051
31 Water, Water intended for human consumption Colour
Range (4 – 100) mg/l Pt/Co
Spectrophotometric method PN-EN ISO 7887:2012 metoda C+Ap1:2015-06
32 Water Chemical oxygen demand
COD Range (4,00 – 150) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
33 Water, Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007, z wyłączeniem punktów 4.4.3, 4.4.4.1, 4.4.5, 4.4.6
34 Water, Water intended for human consumption Total microorganism count at a temperature of 22°C Plate method, pour plate PN-EN ISO 6222:2004
35 Water, Water intended for human consumption Total microorganism count at 36°C Plate method, pour plate PN-EN ISO 6222:2004
36 Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
37 Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04
38 Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04
39 Water, Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
40 Water, Water intended for human consumption Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
41 Water, Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10
42 Water Count of bacteria of the genus Legionella, Matrix B, Procedure 7 (medium C-GVPC) Membrane filtration method PN-EN ISO 11731:2017-08+Ap1:2019-12
43 Water intended for human consumption Most probable number of Pseudomonas aeruginosa MPN method PN-EN ISO 16266-2:2022-04

Reference standards (42)

PL-B-01 wydanie 5 z dnia 04.05.2010 r.
PL-B-04 wydanie 5 z dnia 01.06.2018 r.
PL-B-05 wyd. 5 z dnia 22.05.2023 r.
PL-B-05 wydanie 5 z dnia 22.05.2023 r.
PL-B-06 wydanie 3 z dnia 04.05.2010 r.
PL-B-07 wydanie 3 z dnia 04.05.2010 r.
PL-B-09 wydanie 2 z dnia 04.05.2010 r.
PL-B-10 wydanie 3 z dnia 19.05.2016 r.
PL-B-12 wydanie 2 z dnia 02.06.2017 r.
PL-B-16 wydanie 1 z dnia 12.05.2014 r.
PN- ISO 5667-10:2021-11
PN-C-04554-4:1999, Załącznik A
PN-EN 1899-2:2002
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08+Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 16266-2:2022-04
PN-EN ISO 19458:2007, z wyłączeniem punktów 4.4.3, 4.4.4.1, 4.4.5, 4.4.6
PN-EN ISO 5814:2013-04
PN-EN ISO 5815-1:2019:12
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C+Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12+A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-5:2017-10
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 9297:1994
na podstawie testu HACH LANGE nr 032
na podstawie testu Merck nr 1006130001 i 1147630001
na podstawie testu Merck nr 1097130001
na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051
na podstawie testu Merck nr 1147520001
na podstawie testu Merck nr 1147610001
na podstawie testu Merck nr 1148250001
na podstawie testu Merck nr 1148480001