{"lab":{"_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","address":"ul. Kilińskiego 25 A, 58-200 Dzierżoniów, DZIAŁ LABORATORIUM, ul. Relaksowa 5, 58-200 Dzierżoniów","categories":["water","microbiology"],"city":"Dzierżoniów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":43,"name":"WODOCIĄGI I KANALIZACJA Sp. z o.o.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_756.pdf"],"scope_summary":"","search_text":"wodociągi i kanalizacja sp. z o.o. ul. kilińskiego 25 a, 58-200 dzierżoniów, dział laboratorium, ul. relaksowa 5, 58-200 dzierżoniów water other pharma electronics microbiology","status":"active","updated_at":"2026-03-08T14:51:38.838Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T01:03:22.391Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20756,podmiot.html","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P","pl":"Badania chemiczne i pobieranie próbek wody, ścieków, wody do spożycia przez ludzi","en":"Chemical tests and sampling of water, sewage, drinking water"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water and drinking water"},{"codes":"N/28/P; N/29/P; N/30/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, ścieków, wody do spożycia przez ludzi","en":"Tests of physical properties and sampling of water, sewage, drinking water"}],"issue":{"no":"18","date":"23.07.2026"},"parse_date":"2026-08-18T01:03:22.391Z","parse_source":"agent-claude-code","map_coord":[50.725356,16.635497],"map_geo":"nominatim-street","lab_locations":[{"name":"DZIAŁ LABORATORIUM","address":"ul. Relaksowa 5","city":"Dzierżoniów","postal":"58-200"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/8aa697ad8f8a024e6a01fd79e4c4cf91/AB%20756.pdf","has_en":true,"category_counts":{"water":43,"microbiology":6},"category_scores":{"water":37.73,"microbiology":0.73},"has_zh":true},"methods":[{"_id":"6a83af5aaf14b9c0e7b20515","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych.","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych.\nMetoda manualna; Metoda automatyczna","reference":"PN- ISO 5667-10:2021-11","norm_bases":["PN- ISO 5667-10:2021-11"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych.\nMetoda manualna; Metoda automatyczna PN- ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych.\nMetoda manualna; Metoda automatyczna PN- ISO 5667-10:2021-11","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing.","search_en":"Wastewater Sampling for chemical and physical testing. Manual method; Automatic method PN- ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","search_zh":"污水 手动法；自动法 PN- ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a83af5aaf14b9c0e7b20516","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium","flexible":false,"search_text":"Ścieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a83af5aaf14b9c0e7b20517","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,10 – 110) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,10 – 110) mg/l\nMetoda spektrofotometryczna","reference":"PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001","norm_bases":["PL-B-07 wydanie 3 z dnia 04.05.2010 r.","na podstawie testu Merck nr 1147520001"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (0,10 – 110) mg/l\nMetoda spektrofotometryczna PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001 Scieki Stezenie azotu amonowego\nZakres (0,10 – 110) mg/l\nMetoda spektrofotometryczna PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,10 – 110) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Spectrophotometric method Range PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,10 – 110) mg/l"}],"search_zh":"污水 氨氮浓度 分光光度法 范围 PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83af5aaf14b9c0e7b20518","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,50 – 25,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,50 – 25,0) mg/l\nMetoda spektrofotometryczna","reference":"PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001","norm_bases":["PL-B-06 wydanie 3 z dnia 04.05.2010 r.","na podstawie testu Merck nr 1097130001"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,50 – 25,0) mg/l\nMetoda spektrofotometryczna PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001 Scieki Stezenie azotu azotanowego\nZakres (0,50 – 25,0) mg/l\nMetoda spektrofotometryczna PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 25,0) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 25,0) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83af5aaf14b9c0e7b20519","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 45) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,05 – 45) mg/l\nMetoda spektrofotometryczna","reference":"PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001","norm_bases":["PL-B-04 wydanie 5 z dnia 01.06.2018 r.","na podstawie testu Merck nr 1148480001"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,05 – 45) mg/l\nMetoda spektrofotometryczna PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001 Scieki Stezenie fosforu ogolnego\nZakres (0,05 – 45) mg/l\nMetoda spektrofotometryczna PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,05 – 45) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 45) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83af5aaf14b9c0e7b2051a","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(2,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (2,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(2,0 – 1000) mg/l"}],"search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(2,0 – 1000) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a83af5aaf14b9c0e7b2051b","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(20 – 1000) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (20 – 1000) mg/l\nMetoda turbidymetryczna","reference":"PL-B-05 wydanie 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051","norm_bases":["PL-B-05 wydanie 5 z dnia 22.05.2023 r.","na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie siarczanów\nZakres (20 – 1000) mg/l\nMetoda turbidymetryczna PL-B-05 wydanie 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051 Scieki Stezenie siarczanow\nZakres (20 – 1000) mg/l\nMetoda turbidymetryczna PL-B-05 wydanie 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(20 – 1000) mg/l"}],"search_en":"Wastewater Sulfate concentration Turbidimetric method Range PL-B-05 wydanie 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051","technique_en":"Turbidimetric method","test_object_en":"Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(20 – 1000) mg/l"}],"search_zh":"污水 硫酸盐浓度 浊度法 范围 PL-B-05 wydanie 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051","test_object_zh":"污水","technique_zh":"浊度法"},{"_id":"6a83af5aaf14b9c0e7b2051c","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT"},{"name":"Zakres","range":"(4,00 – 5000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (4,00 – 5000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (4,00 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (4,00 – 5000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD"},{"name":"Range","range":"(4,00 – 5000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand Spectrophotometric method COD Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"化学需氧量（COD）"},{"name":"范围","range":"(4,00 – 5000) mg/l O2"}],"search_zh":"污水 化学需氧量（COD） 分光光度法 化学需氧量（COD） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a83af5aaf14b9c0e7b2051d","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi, Ścieki","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(100 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium","flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi, Ścieki Przewodność elektryczna właściwa\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, Woda do spozycia przez ludzi, Scieki Przewodnosc elektryczna wlasciwa\nZakres (100 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(100 – 3000) μS/cm"}],"search_en":"Water, Water intended for human consumption, Wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water, Water intended for human consumption, Wastewater","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(100 – 3000) μS/cm"}],"search_zh":"水、生活饮用水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水、废水"},{"_id":"6a83af5aaf14b9c0e7b2051e","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie azotu ogólnego","parameters":[{"name":"Zakres","range":"(0,50 – 150) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu ogólnego\nZakres (0,50 – 150) mg/l\nMetoda spektrofotometryczna","reference":"PL-B-10 wydanie 3 z dnia 19.05.2016 r. | na podstawie testu Merck nr 1006130001 i 1147630001","norm_bases":["PL-B-10 wydanie 3 z dnia 19.05.2016 r.","na podstawie testu Merck nr 1006130001 i 1147630001"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie azotu ogólnego\nZakres (0,50 – 150) mg/l\nMetoda spektrofotometryczna PL-B-10 wydanie 3 z dnia 19.05.2016 r. | na podstawie testu Merck nr 1006130001 i 1147630001 Woda, Scieki Stezenie azotu ogolnego\nZakres (0,50 – 150) mg/l\nMetoda spektrofotometryczna PL-B-10 wydanie 3 z dnia 19.05.2016 r. | na podstawie testu Merck nr 1006130001 i 1147630001","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,50 – 150) mg/l"}],"search_en":"Water, Wastewater Total nitrogen concentration Spectrophotometric method Range PL-B-10 wydanie 3 z dnia 19.05.2016 r. | na podstawie testu Merck nr 1006130001 i 1147630001","technique_en":"Spectrophotometric method","test_object_en":"Water, Wastewater","methodology_zh":"总氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 150) mg/l"}],"search_zh":"水、污水 总氮浓度 分光光度法 范围 PL-B-10 wydanie 3 z dnia 19.05.2016 r. | na podstawie testu Merck nr 1006130001 i 1147630001","technique_zh":"分光光度法","test_object_zh":"水、污水"},{"_id":"6a83af5aaf14b9c0e7b2051f","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(2,0 – 5000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Zawiesiny ogólne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, Scieki Zawiesiny ogolne\nZakres (2,0 – 5000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(2,0 – 5000) mg/l"}],"search_en":"Water, Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water, Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 5000) mg/l"}],"search_zh":"水、污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、污水"},{"_id":"6a83af5aaf14b9c0e7b20520","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Stężenie tlenu rozpuszczonego","parameters":[{"name":"Zakres","range":"(1,0 – 15,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (1,0 – 15,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04","norm_bases":["PN-EN ISO 5814:2013-04"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Stężenie tlenu rozpuszczonego\nZakres (1,0 – 15,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04 Woda, Scieki Stezenie tlenu rozpuszczonego\nZakres (1,0 – 15,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Dissolved oxygen concentration","parameters_en":[{"name":"Range","range":"(1,0 – 15,0) mg/l O2"}],"search_en":"Water, Wastewater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 15,0) mg/l O2"}],"search_zh":"水、污水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04","technique_zh":"电化学法","test_object_zh":"水、污水","methodology_zh":"溶解氧浓度"},{"_id":"6a83af5aaf14b9c0e7b20521","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(3,0 – 2000) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 – 2000) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019:12","norm_bases":["PN-EN ISO 5815-1:2019:12"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 – 2000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019:12 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (3,0 – 2000) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019:12","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(3,0 – 2000) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN ISO 5815-1:2019:12","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(3,0 – 2000) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019:12","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a83af5aaf14b9c0e7b20522","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Ścieki","methodology":"Biochemiczne zapotrzebowanie tlenu","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1,0 – 6,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, Scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1,0 – 6,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Biochemical oxygen demand","parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1,0 – 6,0) mg/l O2"}],"search_en":"Water, Wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","technique_en":"Electrochemical method","test_object_en":"Water, Wastewater","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1,0 – 6,0) mg/l O2"}],"search_zh":"水、污水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、污水"},{"_id":"6a83af5aaf14b9c0e7b20523","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda, Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water, Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water, Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"水、生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b20524","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b20525","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,040 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,040 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PL-B-12 wydanie 2 z dnia 02.06.2017 r.","norm_bases":["PL-B-12 wydanie 2 z dnia 02.06.2017 r."],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":"+ Badania wykonywane w siedzibie i poza siedzibą laboratorium","flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chloru wolnego\nZakres (0,040 – 2,00) mg/l\nMetoda spektrofotometryczna PL-B-12 wydanie 2 z dnia 02.06.2017 r. Woda, Woda do spozycia przez ludzi Stezenie chloru wolnego\nZakres (0,040 – 2,00) mg/l\nMetoda spektrofotometryczna PL-B-12 wydanie 2 z dnia 02.06.2017 r.","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,040 – 2,00) mg/l"}],"search_en":"Water, Water intended for human consumption Free chlorine concentration Spectrophotometric method Range PL-B-12 wydanie 2 z dnia 02.06.2017 r.","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 2,00) mg/l"}],"search_zh":"水、生活饮用水 游离氯浓度 分光光度法 范围 PL-B-12 wydanie 2 z dnia 02.06.2017 r.","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b20526","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 10) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 10) mg/l"}],"search_en":"Water, Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10) mg/l"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b20527","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water, Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b20528","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie jonów amonowych","parameters":[{"name":"Zakres","range":"(0,040 – 0,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonów amonowych\nZakres (0,040 – 0,60) mg/l\nMetoda spektrofotometryczna","reference":"PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001","norm_bases":["PL-B-07 wydanie 3 z dnia 04.05.2010 r.","na podstawie testu Merck nr 1147520001"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie jonów amonowych\nZakres (0,040 – 0,60) mg/l\nMetoda spektrofotometryczna PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001 Woda, Woda do spozycia przez ludzi Stezenie jonow amonowych\nZakres (0,040 – 0,60) mg/l\nMetoda spektrofotometryczna PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,040 – 0,60) mg/l"}],"search_en":"Water, Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,040 – 0,60) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 PL-B-07 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147520001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"铵离子浓度"},{"_id":"6a83af5aaf14b9c0e7b20529","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(2,20– 70,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (2,20– 70,0) mg/l\nMetoda spektrofotometryczna","reference":"PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001","norm_bases":["PL-B-06 wydanie 3 z dnia 04.05.2010 r.","na podstawie testu Merck nr 1097130001"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów\nZakres (2,20– 70,0) mg/l\nMetoda spektrofotometryczna PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001 Woda, Woda do spozycia przez ludzi Stezenie azotanow\nZakres (2,20– 70,0) mg/l\nMetoda spektrofotometryczna PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(2,20– 70,0) mg/l"}],"search_en":"Water, Water intended for human consumption Nitrate concentration Spectrophotometric method Range PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(2,20– 70,0) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 PL-B-06 wydanie 3 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1097130001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b2052a","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie fosforanów","parameters":[{"name":"Zakres","range":"(0,10 – 3,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforanów\nZakres (0,10 – 3,00) mg/l\nMetoda spektrofotometryczna","reference":"PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001","norm_bases":["PL-B-04 wydanie 5 z dnia 01.06.2018 r.","na podstawie testu Merck nr 1148480001"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie fosforanów\nZakres (0,10 – 3,00) mg/l\nMetoda spektrofotometryczna PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001 Woda, Woda do spozycia przez ludzi Stezenie fosforanow\nZakres (0,10 – 3,00) mg/l\nMetoda spektrofotometryczna PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phosphate concentration","parameters_en":[{"name":"Range","range":"(0,10 – 3,00) mg/l"}],"search_en":"Water, Water intended for human consumption Phosphate concentration Spectrophotometric method Range PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,10 – 3,00) mg/l"}],"search_zh":"水、生活饮用水 磷酸盐浓度 分光光度法 范围 PL-B-04 wydanie 5 z dnia 01.06.2018 r. | na podstawie testu Merck nr 1148480001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"磷酸盐浓度"},{"_id":"6a83af5aaf14b9c0e7b2052b","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Twardość ogólna (Stężenie sumaryczne wapnia i magnezu)","parameters":[{"name":"Zakres","range":"(5,0 – 1000 mg) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Twardość ogólna (Stężenie sumaryczne wapnia i magnezu)\nZakres (5,0 – 1000 mg) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Twardość ogólna (Stężenie sumaryczne wapnia i magnezu)\nZakres (5,0 – 1000 mg) mg/l\nMetoda miareczkowa PN-ISO 6059:1999 Woda, Woda do spozycia przez ludzi Twardosc ogolna (Stezenie sumaryczne wapnia i magnezu)\nZakres (5,0 – 1000 mg) mg/l\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total hardness (Total concentration of calcium and magnesium)","parameters_en":[{"name":"Range","range":"(5,0 – 1000 mg) mg/l"}],"search_en":"Water, Water intended for human consumption Total hardness (Total concentration of calcium and magnesium) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(5,0 – 1000 mg) mg/l"}],"search_zh":"水、生活饮用水 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b2052c","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2,0 – 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2,0 – 200) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie wapnia\nZakres (2,0 – 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, Woda do spozycia przez ludzi Stezenie wapnia\nZakres (2,0 – 200) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(2,0 – 200) mg/l"}],"search_en":"Water, Water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2,0 – 200) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a83af5aaf14b9c0e7b2052d","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie magnezu","parameters":[],"technique":"metoda (z obliczeń)","techniques":["metoda (z obliczeń)"],"computed":[],"activity":"Stężenie magnezu\nmetoda (z obliczeń)","reference":"PN-C-04554-4:1999, Załącznik A","norm_bases":["PN-C-04554-4:1999, Załącznik A"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie magnezu\nmetoda (z obliczeń) PN-C-04554-4:1999, Załącznik A Woda, Woda do spozycia przez ludzi Stezenie magnezu\nmetoda (z obliczen) PN-C-04554-4:1999, Zalacznik A","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration","search_en":"Water, Water intended for human consumption Magnesium concentration PN-C-04554-4:1999, Załącznik A","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 镁浓度 PN-C-04554-4:1999, Załącznik A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度"},{"_id":"6a83af5aaf14b9c0e7b2052e","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,030 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,030 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PL-B-01 wydanie 5 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147610001","norm_bases":["PL-B-01 wydanie 5 z dnia 04.05.2010 r.","na podstawie testu Merck nr 1147610001"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,030 – 5,0) mg/l\nMetoda spektrofotometryczna PL-B-01 wydanie 5 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147610001 Woda, Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,030 – 5,0) mg/l\nMetoda spektrofotometryczna PL-B-01 wydanie 5 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147610001","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,030 – 5,0) mg/l"}],"search_en":"Water, Water intended for human consumption Total iron concentration Spectrophotometric method Range PL-B-01 wydanie 5 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147610001","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,030 – 5,0) mg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PL-B-01 wydanie 5 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1147610001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b2052f","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,010 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,010 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PL-B-16 wydanie 1 z dnia 12.05.2014 r. | na podstawie testu HACH LANGE nr 032","norm_bases":["PL-B-16 wydanie 1 z dnia 12.05.2014 r.","na podstawie testu HACH LANGE nr 032"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,010 – 2,00) mg/l\nMetoda spektrofotometryczna PL-B-16 wydanie 1 z dnia 12.05.2014 r. | na podstawie testu HACH LANGE nr 032 Woda, Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,010 – 2,00) mg/l\nMetoda spektrofotometryczna PL-B-16 wydanie 1 z dnia 12.05.2014 r. | na podstawie testu HACH LANGE nr 032","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,010 – 2,00) mg/l"}],"search_en":"Water, Water intended for human consumption Manganese concentration Spectrophotometric method Range PL-B-16 wydanie 1 z dnia 12.05.2014 r. | na podstawie testu HACH LANGE nr 032","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 2,00) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PL-B-16 wydanie 1 z dnia 12.05.2014 r. | na podstawie testu HACH LANGE nr 032","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b20530","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie glinu","parameters":[{"name":"Zakres","range":"(0,060 – 0,70) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu\nZakres (0,060 – 0,70) mg/l\nMetoda spektrofotometryczna","reference":"PL-B-09 wydanie 2 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1148250001","norm_bases":["PL-B-09 wydanie 2 z dnia 04.05.2010 r.","na podstawie testu Merck nr 1148250001"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie glinu\nZakres (0,060 – 0,70) mg/l\nMetoda spektrofotometryczna PL-B-09 wydanie 2 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1148250001 Woda, Woda do spozycia przez ludzi Stezenie glinu\nZakres (0,060 – 0,70) mg/l\nMetoda spektrofotometryczna PL-B-09 wydanie 2 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1148250001","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(0,060 – 0,70) mg/l"}],"search_en":"Water, Water intended for human consumption Aluminium concentration Spectrophotometric method Range PL-B-09 wydanie 2 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1148250001","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,060 – 0,70) mg/l"}],"search_zh":"水、生活饮用水 铝浓度 分光光度法 范围 PL-B-09 wydanie 2 z dnia 04.05.2010 r. | na podstawie testu Merck nr 1148250001","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"铝浓度"},{"_id":"6a83af5aaf14b9c0e7b20531","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(2,00– 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (2,00– 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie chlorków\nZakres (2,00– 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (2,00– 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(2,00– 250) mg/l"}],"search_en":"Water, Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(2,00– 250) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b20532","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 – 250) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 – 250) mg/l\nMetoda turbidymetryczna","reference":"PL-B-05 wyd. 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051","norm_bases":["PL-B-05 wyd. 5 z dnia 22.05.2023 r.","na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (10 – 250) mg/l\nMetoda turbidymetryczna PL-B-05 wyd. 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051 Woda, Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (10 – 250) mg/l\nMetoda turbidymetryczna PL-B-05 wyd. 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 – 250) mg/l"}],"search_en":"Water, Water intended for human consumption Sulfate concentration Turbidimetric method Range PL-B-05 wyd. 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051","technique_en":"Turbidimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 – 250) mg/l"}],"search_zh":"水、生活饮用水 硫酸盐浓度 浊度法 范围 PL-B-05 wyd. 5 z dnia 22.05.2023 r. | na podstawie testu Merck nr 1145480001 i HACH LANGE nr 8051","test_object_zh":"水、生活饮用水","technique_zh":"浊度法"},{"_id":"6a83af5aaf14b9c0e7b20533","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(4 – 100) mg/l Pt/Co"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (4 – 100) mg/l Pt/Co\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 metoda C+Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 metoda C+Ap1:2015-06"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Barwa\nZakres (4 – 100) mg/l Pt/Co\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C+Ap1:2015-06 Woda, Woda do spozycia przez ludzi Barwa\nZakres (4 – 100) mg/l Pt/Co\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 metoda C+Ap1:2015-06","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(4 – 100) mg/l Pt/Co"}],"search_en":"Water, Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 metoda C+Ap1:2015-06","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(4 – 100) mg/l Pt/Co"}],"search_zh":"水、生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 metoda C+Ap1:2015-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b20534","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda","methodology":"Chemiczne zapotrzebowanie tlenu","parameters":[{"name":"ChZT"},{"name":"Zakres","range":"(4,00 – 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (4,00 – 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (4,00 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu\nZakres:\nChZT\nZakres (4,00 – 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand","parameters_en":[{"name":"COD"},{"name":"Range","range":"(4,00 – 150) mg/l O2"}],"search_en":"Water Chemical oxygen demand Spectrophotometric method COD Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"化学需氧量（COD）"},{"name":"范围","range":"(4,00 – 150) mg/l O2"}],"search_zh":"水 化学需氧量（COD） 分光光度法 化学需氧量（COD） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"化学需氧量（COD）"},{"_id":"6a83af5aaf14b9c0e7b20535","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007, z wyłączeniem punktów 4.4.3, 4.4.4.1, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007, z wyłączeniem punktów 4.4.3, 4.4.4.1, 4.4.5, 4.4.6"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007, z wyłączeniem punktów 4.4.3, 4.4.4.1, 4.4.5, 4.4.6 Woda, Woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007, z wylaczeniem punktow 4.4.3, 4.4.4.1, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water, Water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007, z wyłączeniem punktów 4.4.3, 4.4.4.1, 4.4.5, 4.4.6","test_object_en":"Water, Water intended for human consumption","methodology_zh":"微生物检测用样品采集","search_zh":"水、生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007, z wyłączeniem punktów 4.4.3, 4.4.4.1, 4.4.5, 4.4.6","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b20536","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22°C","parameters":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22°C\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 22°C\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 22°C\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total microorganism count at a temperature of 22°C","search_en":"Water, Water intended for human consumption Total microorganism count at a temperature of 22°C Plate method, pour plate PN-EN ISO 6222:2004","technique_en":"Plate method, pour plate","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 22°C 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水","technique_zh":"平板法，倾注平板","methodology_zh":"22°C 微生物总数"},{"_id":"6a83af5aaf14b9c0e7b20537","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36°C","parameters":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36°C\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 36°C\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda, Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 36°C\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total microorganism count at 36°C","search_en":"Water, Water intended for human consumption Total microorganism count at 36°C Plate method, pour plate PN-EN ISO 6222:2004","technique_en":"Plate method, pour plate","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 36°C 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"水、生活饮用水","technique_zh":"平板法，倾注平板","methodology_zh":"36°C 微生物总数"},{"_id":"6a83af5aaf14b9c0e7b20538","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b20539","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+A1:2017-04"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04","categories":["water","microbiology"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b2053a","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12+A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12+A1:2017-04"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12+A1:2017-04","categories":["water","microbiology"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12+A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b2053b","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria","search_en":"Water, Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a83af5aaf14b9c0e7b2053c","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Escherichia coli","search_en":"Water, Water intended for human consumption Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a83af5aaf14b9c0e7b2053d","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, Woda do spozycia przez ludzi Liczba Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count (including spores)","search_en":"Water, Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 产气荚膜梭菌计数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"产气荚膜梭菌计数（含芽孢）"},{"_id":"6a83af5aaf14b9c0e7b2053e","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 7 (pożywka C-GVPC)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 7 (pożywka C-GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08+Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08+Ap1:2019-12"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 7 (pożywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08+Ap1:2019-12 Woda Liczba bakterii z rodzaju Legionella, Matryca B, Procedura 7 (pozywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08+Ap1:2019-12","categories":["microbiology","water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of bacteria of the genus Legionella, Matrix B, Procedure 7 (medium C-GVPC)","search_en":"Water Count of bacteria of the genus Legionella, Matrix B, Procedure 7 (medium C-GVPC) Membrane filtration method PN-EN ISO 11731:2017-08+Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water","search_zh":"水 膜过滤法 PN-EN ISO 11731:2017-08+Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a83af5aaf14b9c0e7b2053f","lab_id":"69ad52a3de79e566650fb3cc","country":"PL","accr_number":"AB 756","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Pseudomonas aeruginosa\nMetoda NPL","reference":"PN-EN ISO 16266-2:2022-04","norm_bases":["PN-EN ISO 16266-2:2022-04"],"lab_section":"Dział laboratorium","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba Pseudomonas aeruginosa\nMetoda NPL PN-EN ISO 16266-2:2022-04 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba Pseudomonas aeruginosa\nMetoda NPL PN-EN ISO 16266-2:2022-04","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Pseudomonas aeruginosa","search_en":"Water intended for human consumption Most probable number of Pseudomonas aeruginosa MPN method PN-EN ISO 16266-2:2022-04","technique_en":"MPN method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 最可能数法（MPN） PN-EN ISO 16266-2:2022-04","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水"}],"has_pdf":true}