🇵🇱 POLITECHNIKA KRAKOWSKA im. Tadeusza Kościuszki PL

PCA AB 749 • Kraków, Poland • 3 methods

Water & wastewaterEnvironmentFood & beverages

POLITECHNIKA KRAKOWSKA im. Tadeusza Kościuszki is a laboratory accredited by PCA under number AB 749 (Kraków, Poland). Its accreditation scope covers 3 test methods in the following areas: Water & wastewater, Environment, Food & beverages. Test objects include: Fertilisers: - mineral (inorganic) fertilisers - solid fertilisers, Food E), Samples of biological origin E), Feed and feed additives,…. Most frequently used techniques: Gas chromatography with tandem mass spectrometry detection (GC-MS/MS).

At a glance

  • Accreditation number: PCA AB 749
  • Methods in scope: 3
  • Types of test objects: 2
  • Techniques used: 1
  • City: Kraków, Poland
Accreditation number
AB 749
Accreditation body
PCA
Address
LABORATORIUM ANALIZ ŚLADOWYCH im. Profesora Adama Grochowalskiego, ul. Warszawska 24, 31-155 Kraków
City
Kraków, Poland

What this laboratory tests (2)

Analytical techniques used (1)

Laboratory locations

Accreditation scope — test methods (3)

No. Test object Methodology / Parameters Technique Reference document
Laboratorium Analiz Śladowych im. Profesora Adama Grochowalskiego
1 Fertilisers: - mineral (inorganic) fertilisers - solid fertilisers Content:
polychlorinated dibenzodioxins (PCDD) polychlorinated dibenzofurans (PCDF) PCDD congeners: 2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD PCDF congeners: 2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF Range (0.01-250000) pg-TEQ/g produktu Suma dioksyn wyrażona w (WHO-PCDD/F-TEQ) (z obliczeń)
Gas chromatography with tandem mass spectrometry detection (GC-MS/MS) Procedura P/ 01 wydanie 05 z dnia 16.05.2023
2 Fertilisers: - mineral (inorganic) fertilisers - solid fertilisers Content:
polychlorinated biphenyls (PCB) PCB congeners: (dioxin-like dl-PCB) PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189 Range (0.002-200000) pg-TEQ/g produktu Suma dioksynopodobnych (dl-PCB) wyrażona w (WHO-PCB-TEQ) (z obliczeń) Suma dioksyn i dioksynopodobnych (dl-PCB) wyrażona w (WHO-PCDD/F-PCB-TEQ) (z obliczeń) PCB congeners (non-dioxin-like ndl-PCB) PCB28 PCB52 PCB101 PCB138 PCB153 PCB180 Range 0.1 – 50000000 pg/g produktu Sum of ndl-PCB (calculated)
Gas chromatography with tandem mass spectrometry detection (GC-MS/MS) Procedura P/ 01 wydanie 05 z dnia 16.05.2023
3 Food E), Samples of biological origin E), Feed and feed additives, Agricultural products E), Soil E), Sediments E), Minerals E), Chemical products E), Waste E), Water and wastewater E), Gas samples taken from industrial installations collected on filters, sorbent and condensate E), Ambient air and indoor air samples collected on filters and/or sorbent E) Content:
polychlorinated dibenzodioxins (PCDD) polychlorinated dibenzofurans (PCDF) polychlorinated biphenyls (PCB)
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Gas chromatography with tandem mass spectrometry detection (GC-MS/MS) Procedura P/01

Reference standards (2)

Procedura P/ 01 wydanie 05 z dnia 16.05.2023
Procedura P/01