{"lab":{"_id":"69ad52a3de79e566650fb3c4","country":"PL","accr_number":"AB 749","accr_body":"PCA","address":"LABORATORIUM ANALIZ ŚLADOWYCH im. Profesora Adama Grochowalskiego, ul. Warszawska 24, 31-155 Kraków","categories":["food","water","environment"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":3,"name":"POLITECHNIKA KRAKOWSKA im. Tadeusza Kościuszki","parse_status":"parsed","parse_version":2,"pdf_files":["AB_749.pdf"],"scope_summary":"","search_text":"politechnika krakowska im. tadeusza kościuszki laboratorium analiz śladowych im. profesora adama grochowalskiego, ul. warszawska 24, 31-155 kraków other food environment","status":"active","updated_at":"2026-03-08T14:51:38.495Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-18T00:55:18.086Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20749,podmiot.html","fields_of_testing":[{"codes":"C/1; C/3; C/4; C/9; C/22; C/28; C/30; C/36; C/31; C/32; C/55; C/43","pl":"Badania chemiczne produktów rolnych; obiektów i materiałów biologicznych przeznaczonych do badań; wyrobów chemicznych; powietrza; żywności; wody, gazów; ścieków; gleby; osadów, odpadów; pasz dla zwierząt, nawozy","en":"Chemical tests of agricultural products; biological items and materials for testing; chemical products; food; water; gases; sewage; soil; sediments; air; animal feedstuffs, fertilizers","de":"Chemische Prüfungen landwirtschaftlicher Erzeugnisse; biologischer Objekte und Materialien für Prüfzwecke; chemischer Erzeugnisse; von Luft; Lebensmitteln; Wasser, Gasen; Abwasser; Boden; Sedimenten, Abfällen; Futtermitteln, Düngemitteln","zh":"农产品；供检测的生物对象和材料；化学产品；空气；食品；水、气体；废水；土壤；沉积物、废物；动物饲料、肥料的化学检测","cs":"Chemické zkoušky zemědělských produktů; biologických objektů a materiálů určených ke zkouškám; chemických výrobků; ovzduší; potravin; vody, plynů; odpadních vod; půdy; sedimentů, odpadů; krmiv pro zvířata, hnojiv"}],"issue":{"no":"20","date":"21.07.2026"},"parse_date":"2026-08-18T00:55:18.086Z","parse_source":"agent-claude-code","map_coord":[50.071547,19.943933],"map_geo":"nominatim-street","lab_locations":[{"code":null,"name":"POLITECHNIKA KRAKOWSKA im. Tadeusza Kościuszki","street":"ul. Warszawska 24","postal_code":"31-155","city":"Kraków","is_hq":true,"address":"ul. Warszawska 24, 31-155 Kraków","site":"31-155|warszawska24"},{"code":null,"name":"LABORATORIUM ANALIZ ŚLADOWYCH im. Profesora Adama Grochowalskiego","street":"ul. Warszawska 24","postal_code":"31-155","city":"Kraków","is_hq":false,"address":"ul. Warszawska 24, 31-155 Kraków","site":"31-155|warszawska24"}],"scope_format":"PCA::pracownie+elastyczny+siatka5","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/3c784f6ce814d0369a436e96e417c731/AB%20749.pdf","has_en":true,"category_counts":{"other":2,"food":1,"water":1,"environment":1},"category_scores":{"other":0.8,"food":0.2,"water":0.2,"environment":0.2},"has_zh":true,"lab_locations_en":[{"code":null,"name":"POLITECHNIKA KRAKOWSKA im. Tadeusza Kościuszki","street":"ul. Warszawska 24","postal_code":"31-155","city":"Kraków","is_hq":true,"address":"ul. Warszawska 24, 31-155 Kraków","site":"31-155|warszawska24"},{"code":null,"name":"PROFESSOR ADAM GROCHOWALSKI TRACE ANALYSIS LABORATORY","street":"ul. Warszawska 24","postal_code":"31-155","city":"Kraków","is_hq":false,"address":"ul. Warszawska 24, 31-155 Kraków","site":"31-155|warszawska24"}],"has_de":true,"lab_locations_de":[{"code":null,"name":"POLITECHNIKA KRAKOWSKA im. Tadeusza Kościuszki","street":"ul. Warszawska 24","postal_code":"31-155","city":"Kraków","is_hq":true,"address":"ul. Warszawska 24, 31-155 Kraków","site":"31-155|warszawska24"},{"code":null,"name":"LABOR FÜR SPURENANALYSEN NAMENS PROFESSOR ADAM GROCHOWALSKI","street":"ul. Warszawska 24","postal_code":"31-155","city":"Kraków","is_hq":false,"address":"ul. Warszawska 24, 31-155 Kraków","site":"31-155|warszawska24"}],"lab_locations_zh":[{"code":null,"name":"POLITECHNIKA KRAKOWSKA im. Tadeusza Kościuszki","street":"ul. Warszawska 24","postal_code":"31-155","city":"Kraków","is_hq":true,"address":"ul. Warszawska 24, 31-155 Kraków","site":"31-155|warszawska24"},{"code":null,"name":"Adam Grochowalski 教授痕量分析实验室","street":"ul. Warszawska 24","postal_code":"31-155","city":"Kraków","is_hq":false,"address":"ul. Warszawska 24, 31-155 Kraków","site":"31-155|warszawska24"}],"has_cs":true,"pelny_cs":true,"lab_locations_cs":[{"code":null,"name":"POLITECHNIKA KRAKOWSKA im. Tadeusza Kościuszki","street":"ul. Warszawska 24","postal_code":"31-155","city":"Kraków","is_hq":true,"address":"ul. Warszawska 24, 31-155 Kraków","site":"31-155|warszawska24"},{"code":null,"name":"LABORATOŘ STOPOVÉ ANALÝZY profesora Adama Grochowalského","street":"ul. Warszawska 24","postal_code":"31-155","city":"Kraków","is_hq":false,"address":"ul. Warszawska 24, 31-155 Kraków","site":"31-155|warszawska24"}]},"methods":[{"_id":"6a83ad76af14b9c0e7b2019c","lab_id":"69ad52a3de79e566650fb3c4","country":"PL","accr_number":"AB 749","accr_body":"PCA","test_object":"Nawozy: - nawozy mineralne (nieorganiczne) - nawozy stałe","methodology":"Zawartość:","parameters":[{"name":"polichlorowanych dibenzodioksyn (PCDD)"},{"name":"polichlorowanych dibenzofuranów (PCDF)"},{"name":"kongenery PCDD: 2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD"},{"name":"kongenery PCDF: 2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF"},{"name":"Zakres","range":"(0.01-250000) pg-TEQ/g produktu"},{"name":"Suma dioksyn wyrażona w (WHO-PCDD/F-TEQ) (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)"],"computed":[],"activity":"Zawartość:\nZakres:\npolichlorowanych dibenzodioksyn (PCDD)\npolichlorowanych dibenzofuranów (PCDF)\nkongenery PCDD: 2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD\nkongenery PCDF: 2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF\nZakres (0.01-250000) pg-TEQ/g produktu\nSuma dioksyn wyrażona w (WHO-PCDD/F-TEQ) (z obliczeń)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)","reference":"Procedura P/ 01 wydanie 05 z dnia 16.05.2023","norm_bases":["Procedura P/ 01 wydanie 05 z dnia 16.05.2023"],"lab_section":"Laboratorium Analiz Śladowych im. Profesora Adama Grochowalskiego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy: - nawozy mineralne (nieorganiczne) - nawozy stałe Zawartość:\nZakres:\npolichlorowanych dibenzodioksyn (PCDD)\npolichlorowanych dibenzofuranów (PCDF)\nkongenery PCDD: 2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD\nkongenery PCDF: 2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF\nZakres (0.01-250000) pg-TEQ/g produktu\nSuma dioksyn wyrażona w (WHO-PCDD/F-TEQ) (z obliczeń)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS) Procedura P/ 01 wydanie 05 z dnia 16.05.2023 Nawozy: - nawozy mineralne (nieorganiczne) - nawozy stale Zawartosc:\nZakres:\npolichlorowanych dibenzodioksyn (PCDD)\npolichlorowanych dibenzofuranow (PCDF)\nkongenery PCDD: 2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD\nkongenery PCDF: 2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF\nZakres (0.01-250000) pg-TEQ/g produktu\nSuma dioksyn wyrazona w (WHO-PCDD/F-TEQ) (z obliczen)\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS/MS) Procedura P/ 01 wydanie 05 z dnia 16.05.2023","categories":["other"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content:","parameters_en":[{"name":"polychlorinated dibenzodioxins (PCDD)"},{"name":"polychlorinated dibenzofurans (PCDF)"},{"name":"PCDD congeners: 2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD"},{"name":"PCDF congeners: 2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF"},{"name":"Range","range":"(0.01-250000) pg-TEQ/g of product"},{"name":"Sum of dioxins expressed as (WHO-PCDD/F-TEQ) (calculated)"}],"search_en":"Fertilisers: - mineral (inorganic) fertilisers - solid fertilisers Content: Gas chromatography with tandem mass spectrometry detection (GC-MS/MS) Professor Adam Grochowalski Trace Analysis Laboratory Gas chromatography with tandem mass spectrometry detection (GC-MS/MS) polychlorinated dibenzodioxins (PCDD) polychlorinated dibenzofurans (PCDF) PCDD congeners: 2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD PCDF congeners: 2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF Range Sum of dioxins expressed as (WHO-PCDD/F-TEQ) (calculated) Procedure P/ 01 issue 05 of 16.05.2023","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS/MS)","test_object_en":"Fertilisers: - mineral (inorganic) fertilisers - solid fertilisers","parameters_zh":[{"name":"多氯二苯并二噁英（PCDD）"},{"name":"多氯二苯并呋喃（PCDF）"},{"name":"PCDD 同类物：2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD"},{"name":"PCDF 同类物：2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF"},{"name":"范围","range":"(0.01-250000) pg-TEQ/g 产品"},{"name":"二噁英总和，以（WHO-PCDD/F-TEQ）表示（计算得出）"}],"search_zh":"肥料：- 矿物（无机）肥料 - 固体肥料 含量： 气相色谱-串联质谱法（GC-MS/MS） Adam Grochowalski 教授痕量分析实验室 气相色谱-串联质谱法（GC-MS/MS） 多氯二苯并二噁英（PCDD） 多氯二苯并呋喃（PCDF） PCDD 同类物：2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD PCDF 同类物：2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF 范围 二噁英总和，以（WHO-PCDD/F-TEQ）表示（计算得出） 程序 P/ 01 第05版（2023年5月16日）","technique_zh":"气相色谱-串联质谱法（GC-MS/MS）","methodology_zh":"含量：","lab_section_en":"Professor Adam Grochowalski Trace Analysis Laboratory","techniques_en":["Gas chromatography with tandem mass spectrometry detection (GC-MS/MS)"],"lab_section_de":"Labor für Spurenanalytik „Professor Adam Grochowalski“","methodology_de":"Gehalt:","parameters_de":[{"name":"polychlorierter Dibenzodioxine (PCDD)"},{"name":"polychlorierter Dibenzofurane (PCDF)"},{"name":"PCDD-Kongenere: 2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD"},{"name":"PCDF-Kongenere: 2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF"},{"name":"Bereich","range":"(0.01-250000) pg-TEQ/g Produkt"},{"name":"Summe der Dioxine, ausgedrückt in (WHO-PCDD/F-TEQ) (berechnet)"}],"search_de":"Düngemittel: - mineralische (anorganische) Düngemittel - feste Düngemittel Gehalt: Gaschromatographie mit Tandem-Massenspektrometrie-Detektion (GC-MS/MS) Labor für Spurenanalytik „Professor Adam Grochowalski“ Gaschromatographie mit Tandem-Massenspektrometrie-Detektion (GC-MS/MS) polychlorierter Dibenzodioxine (PCDD) polychlorierter Dibenzofurane (PCDF) PCDD-Kongenere: 2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD PCDF-Kongenere: 2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF Bereich Summe der Dioxine, ausgedrückt in (WHO-PCDD/F-TEQ) (berechnet) Verfahren P/ 01 Ausgabe 05 vom 16.05.2023","technique_de":"Gaschromatographie mit Tandem-Massenspektrometrie-Detektion (GC-MS/MS)","techniques_de":["Gaschromatographie mit Tandem-Massenspektrometrie-Detektion (GC-MS/MS)"],"test_object_de":"Düngemittel: - mineralische (anorganische) Düngemittel - feste Düngemittel","lab_section_zh":"Adam Grochowalski 教授痕量分析实验室","techniques_zh":["气相色谱-串联质谱法（GC-MS/MS）"],"test_object_zh":"肥料：- 矿物（无机）肥料 - 固体肥料","reference_en":"Procedure P/ 01 issue 05 of 16.05.2023","reference_de":"Verfahren P/ 01 Ausgabe 05 vom 16.05.2023","reference_zh":"程序 P/ 01 第05版（2023年5月16日）","methodology_cs":"Obsah:","parameters_cs":[{"name":"polychlorovaných dibenzodioxinů (PCDD)"},{"name":"polychlorovaných dibenzofuranů (PCDF)"},{"name":"kongenery PCDD: 2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD"},{"name":"kongenery PCDF: 2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF"},{"name":"Rozsah","range":"(0.01-250000) pg-TEQ/g produktu"},{"name":"Suma dioxinů vyjádřená jako (WHO-PCDD/F-TEQ) (výpočtem)"}],"search_cs":"Hnojiva: - minerální (anorganická) hnojiva - tuhá hnojiva Obsah: Metoda plynové chromatografie s tandemovou hmotnostně spektrometrickou detekcí (GC-MS/MS) Laboratoř stopové analýzy profesora Adama Grochowalského Metoda plynové chromatografie s tandemovou hmotnostně spektrometrickou detekcí (GC-MS/MS) polychlorovaných dibenzodioxinů (PCDD) polychlorovaných dibenzofuranů (PCDF) kongenery PCDD: 2,3,7,8-TeCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCDD OCDD kongenery PCDF: 2,3,7,8-TeCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF OCDF Rozsah Suma dioxinů vyjádřená jako (WHO-PCDD/F-TEQ) (výpočtem) Postup P/ 01 vydání 05 ze dne 16.05.2023","technique_cs":"Metoda plynové chromatografie s tandemovou hmotnostně spektrometrickou detekcí (GC-MS/MS)","techniques_cs":["Metoda plynové chromatografie s tandemovou hmotnostně spektrometrickou detekcí (GC-MS/MS)"],"lab_section_cs":"Laboratoř stopové analýzy profesora Adama Grochowalského","reference_cs":"Postup P/ 01 vydání 05 ze dne 16.05.2023","test_object_cs":"Hnojiva: - minerální (anorganická) hnojiva - tuhá hnojiva"},{"_id":"6a83ad76af14b9c0e7b2019d","lab_id":"69ad52a3de79e566650fb3c4","country":"PL","accr_number":"AB 749","accr_body":"PCA","test_object":"Nawozy: - nawozy mineralne (nieorganiczne) - nawozy stałe","methodology":"Zawartość:","parameters":[{"name":"polichlorowanych bifenyli (PCB)"},{"name":"kongenery PCB: (dioksynopodobne dl-PCB) PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189"},{"name":"Zakres","range":"(0.002-200000) pg-TEQ/g produktu"},{"name":"Suma dioksynopodobnych (dl-PCB) wyrażona w (WHO-PCB-TEQ) (z obliczeń)"},{"name":"Suma dioksyn i dioksynopodobnych (dl-PCB) wyrażona w (WHO-PCDD/F-PCB-TEQ) (z obliczeń)"},{"name":"kongenery PCB (niepodobne do dioksyn ndl-PCB) PCB28 PCB52 PCB101 PCB138 PCB153 PCB180"},{"name":"Zakres","range":"0.1 – 50000000 pg/g produktu"},{"name":"Suma ndl-PCB (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)"],"computed":[],"activity":"Zawartość:\nZakres:\npolichlorowanych bifenyli (PCB)\nkongenery PCB: (dioksynopodobne dl-PCB) PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189\nZakres (0.002-200000) pg-TEQ/g produktu\nSuma dioksynopodobnych (dl-PCB) wyrażona w (WHO-PCB-TEQ) (z obliczeń)\nSuma dioksyn i dioksynopodobnych (dl-PCB) wyrażona w (WHO-PCDD/F-PCB-TEQ) (z obliczeń)\nkongenery PCB (niepodobne do dioksyn ndl-PCB) PCB28 PCB52 PCB101 PCB138 PCB153 PCB180\nZakres 0.1 – 50000000 pg/g produktu\nSuma ndl-PCB (z obliczeń)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)","reference":"Procedura P/ 01 wydanie 05 z dnia 16.05.2023","norm_bases":["Procedura P/ 01 wydanie 05 z dnia 16.05.2023"],"lab_section":"Laboratorium Analiz Śladowych im. Profesora Adama Grochowalskiego","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Nawozy: - nawozy mineralne (nieorganiczne) - nawozy stałe Zawartość:\nZakres:\npolichlorowanych bifenyli (PCB)\nkongenery PCB: (dioksynopodobne dl-PCB) PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189\nZakres (0.002-200000) pg-TEQ/g produktu\nSuma dioksynopodobnych (dl-PCB) wyrażona w (WHO-PCB-TEQ) (z obliczeń)\nSuma dioksyn i dioksynopodobnych (dl-PCB) wyrażona w (WHO-PCDD/F-PCB-TEQ) (z obliczeń)\nkongenery PCB (niepodobne do dioksyn ndl-PCB) PCB28 PCB52 PCB101 PCB138 PCB153 PCB180\nZakres 0.1 – 50000000 pg/g produktu\nSuma ndl-PCB (z obliczeń)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS) Procedura P/ 01 wydanie 05 z dnia 16.05.2023 Nawozy: - nawozy mineralne (nieorganiczne) - nawozy stale Zawartosc:\nZakres:\npolichlorowanych bifenyli (PCB)\nkongenery PCB: (dioksynopodobne dl-PCB) PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189\nZakres (0.002-200000) pg-TEQ/g produktu\nSuma dioksynopodobnych (dl-PCB) wyrazona w (WHO-PCB-TEQ) (z obliczen)\nSuma dioksyn i dioksynopodobnych (dl-PCB) wyrazona w (WHO-PCDD/F-PCB-TEQ) (z obliczen)\nkongenery PCB (niepodobne do dioksyn ndl-PCB) PCB28 PCB52 PCB101 PCB138 PCB153 PCB180\nZakres 0.1 – 50000000 pg/g produktu\nSuma ndl-PCB (z obliczen)\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS/MS) Procedura P/ 01 wydanie 05 z dnia 16.05.2023","categories":["other"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content:","parameters_en":[{"name":"polychlorinated biphenyls (PCB)"},{"name":"PCB congeners: (dioxin-like dl-PCB) PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189"},{"name":"Range","range":"(0.002-200000) pg-TEQ/g of product"},{"name":"Sum of dioxin-like PCBs (dl-PCB) expressed as (WHO-PCB-TEQ) (calculated)"},{"name":"Sum of dioxins and dioxin-like PCBs (dl-PCB) expressed as (WHO-PCDD/F-PCB-TEQ) (calculated)"},{"name":"PCB congeners (non-dioxin-like ndl-PCB) PCB28 PCB52 PCB101 PCB138 PCB153 PCB180"},{"name":"Range","range":"0.1 – 50000000 pg/g of product"},{"name":"Sum of ndl-PCB (calculated)"}],"search_en":"Fertilisers: - mineral (inorganic) fertilisers - solid fertilisers Content: Gas chromatography with tandem mass spectrometry detection (GC-MS/MS) Professor Adam Grochowalski Trace Analysis Laboratory Gas chromatography with tandem mass spectrometry detection (GC-MS/MS) polychlorinated biphenyls (PCB) PCB congeners: (dioxin-like dl-PCB) PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189 Range Sum of dioxin-like PCBs (dl-PCB) expressed as (WHO-PCB-TEQ) (calculated) Sum of dioxins and dioxin-like PCBs (dl-PCB) expressed as (WHO-PCDD/F-PCB-TEQ) (calculated) PCB congeners (non-dioxin-like ndl-PCB) PCB28 PCB52 PCB101 PCB138 PCB153 PCB180 Range Sum of ndl-PCB (calculated) Procedure P/ 01 issue 05 of 16.05.2023","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS/MS)","test_object_en":"Fertilisers: - mineral (inorganic) fertilisers - solid fertilisers","parameters_zh":[{"name":"多氯联苯（PCB）"},{"name":"PCB 同类物：（二噁英类 dl-PCB） PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189"},{"name":"范围","range":"(0.002-200000) pg-TEQ/g 产品"},{"name":"类二噁英多氯联苯（dl-PCB）总和，以（WHO-PCB-TEQ）表示（计算得出）"},{"name":"二噁英和类二噁英多氯联苯（dl-PCB）总和，以（WHO-PCDD/F-PCB-TEQ）表示（计算得出）"},{"name":"PCB 同类物（非二噁英类 ndl-PCB） PCB28 PCB52 PCB101 PCB138 PCB153 PCB180"},{"name":"范围","range":"0.1 – 50000000 pg/g 产品"},{"name":"ndl-PCB 总和（计算得出）"}],"search_zh":"肥料：- 矿物（无机）肥料 - 固体肥料 含量： 气相色谱-串联质谱法（GC-MS/MS） Adam Grochowalski 教授痕量分析实验室 气相色谱-串联质谱法（GC-MS/MS） 多氯联苯（PCB） PCB 同类物：（二噁英类 dl-PCB） PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189 范围 类二噁英多氯联苯（dl-PCB）总和，以（WHO-PCB-TEQ）表示（计算得出） 二噁英和类二噁英多氯联苯（dl-PCB）总和，以（WHO-PCDD/F-PCB-TEQ）表示（计算得出） PCB 同类物（非二噁英类 ndl-PCB） PCB28 PCB52 PCB101 PCB138 PCB153 PCB180 范围 ndl-PCB 总和（计算得出） 程序 P/ 01 第05版（2023年5月16日）","technique_zh":"气相色谱-串联质谱法（GC-MS/MS）","methodology_zh":"含量：","lab_section_en":"Professor Adam Grochowalski Trace Analysis Laboratory","techniques_en":["Gas chromatography with tandem mass spectrometry detection (GC-MS/MS)"],"lab_section_de":"Labor für Spurenanalytik „Professor Adam Grochowalski“","methodology_de":"Gehalt:","parameters_de":[{"name":"polychlorierter Biphenyle (PCB)"},{"name":"PCB-Kongenere: (dioxinähnliche dl-PCB) PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189"},{"name":"Bereich","range":"(0.002-200000) pg-TEQ/g Produkt"},{"name":"Summe der dioxinähnlichen PCB (dl-PCB), ausgedrückt in (WHO-PCB-TEQ) (berechnet)"},{"name":"Summe der Dioxine und dioxinähnlichen PCB (dl-PCB), ausgedrückt in (WHO-PCDD/F-PCB-TEQ) (berechnet)"},{"name":"PCB-Kongenere (nicht dioxinähnliche ndl-PCB) PCB28 PCB52 PCB101 PCB138 PCB153 PCB180"},{"name":"Bereich","range":"0.1 – 50000000 pg/g Produkt"},{"name":"Summe ndl-PCB (berechnet)"}],"search_de":"Düngemittel: - mineralische (anorganische) Düngemittel - feste Düngemittel Gehalt: Gaschromatographie mit Tandem-Massenspektrometrie-Detektion (GC-MS/MS) Labor für Spurenanalytik „Professor Adam Grochowalski“ Gaschromatographie mit Tandem-Massenspektrometrie-Detektion (GC-MS/MS) polychlorierter Biphenyle (PCB) PCB-Kongenere: (dioxinähnliche dl-PCB) PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189 Bereich Summe der dioxinähnlichen PCB (dl-PCB), ausgedrückt in (WHO-PCB-TEQ) (berechnet) Summe der Dioxine und dioxinähnlichen PCB (dl-PCB), ausgedrückt in (WHO-PCDD/F-PCB-TEQ) (berechnet) PCB-Kongenere (nicht dioxinähnliche ndl-PCB) PCB28 PCB52 PCB101 PCB138 PCB153 PCB180 Bereich Summe ndl-PCB (berechnet) Verfahren P/ 01 Ausgabe 05 vom 16.05.2023","technique_de":"Gaschromatographie mit Tandem-Massenspektrometrie-Detektion (GC-MS/MS)","techniques_de":["Gaschromatographie mit Tandem-Massenspektrometrie-Detektion (GC-MS/MS)"],"test_object_de":"Düngemittel: - mineralische (anorganische) Düngemittel - feste Düngemittel","lab_section_zh":"Adam Grochowalski 教授痕量分析实验室","techniques_zh":["气相色谱-串联质谱法（GC-MS/MS）"],"test_object_zh":"肥料：- 矿物（无机）肥料 - 固体肥料","reference_en":"Procedure P/ 01 issue 05 of 16.05.2023","reference_de":"Verfahren P/ 01 Ausgabe 05 vom 16.05.2023","reference_zh":"程序 P/ 01 第05版（2023年5月16日）","methodology_cs":"Obsah:","parameters_cs":[{"name":"polychlorovaných bifenylů (PCB)"},{"name":"kongenery PCB: (dioxinům podobné dl-PCB) PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189"},{"name":"Rozsah","range":"(0.002-200000) pg-TEQ/g produktu"},{"name":"Suma dioxinům podobných (dl-PCB) vyjádřená jako (WHO-PCB-TEQ) (výpočtem)"},{"name":"Suma dioxinů a dioxinům podobných (dl-PCB) vyjádřená jako (WHO-PCDD/F-PCB-TEQ) (výpočtem)"},{"name":"kongenery PCB (nepodobné dioxinům ndl-PCB) PCB28 PCB52 PCB101 PCB138 PCB153 PCB180"},{"name":"Rozsah","range":"0.1 – 50000000 pg/g produktu"},{"name":"Suma ndl-PCB (výpočtem)"}],"search_cs":"Hnojiva: - minerální (anorganická) hnojiva - tuhá hnojiva Obsah: Metoda plynové chromatografie s tandemovou hmotnostně spektrometrickou detekcí (GC-MS/MS) Laboratoř stopové analýzy profesora Adama Grochowalského Metoda plynové chromatografie s tandemovou hmotnostně spektrometrickou detekcí (GC-MS/MS) polychlorovaných bifenylů (PCB) kongenery PCB: (dioxinům podobné dl-PCB) PCB77 PCB126 PCB169 PCB81 PCB105 PCB114 PCB118 PCB118 PCB123 PCB156 PCB157 PCB167 PCB189 Rozsah Suma dioxinům podobných (dl-PCB) vyjádřená jako (WHO-PCB-TEQ) (výpočtem) Suma dioxinů a dioxinům podobných (dl-PCB) vyjádřená jako (WHO-PCDD/F-PCB-TEQ) (výpočtem) kongenery PCB (nepodobné dioxinům ndl-PCB) PCB28 PCB52 PCB101 PCB138 PCB153 PCB180 Rozsah Suma ndl-PCB (výpočtem) Postup P/ 01 vydání 05 ze dne 16.05.2023","technique_cs":"Metoda plynové chromatografie s tandemovou hmotnostně spektrometrickou detekcí (GC-MS/MS)","techniques_cs":["Metoda plynové chromatografie s tandemovou hmotnostně spektrometrickou detekcí (GC-MS/MS)"],"lab_section_cs":"Laboratoř stopové analýzy profesora Adama Grochowalského","reference_cs":"Postup P/ 01 vydání 05 ze dne 16.05.2023","test_object_cs":"Hnojiva: - minerální (anorganická) hnojiva - tuhá hnojiva"},{"_id":"6a83ad76af14b9c0e7b2019e","lab_id":"69ad52a3de79e566650fb3c4","country":"PL","accr_number":"AB 749","accr_body":"PCA","test_object":"Żywność E), Próbki pochodzenia biologicznego E), Pasze i dodatki paszowe, Produkty rolne E), Gleba E), Osady E), Minerały E), Wyroby chemiczne E), Odpady E), Woda i ścieki E), Próbki gazów pobrane z urządzeń przemysłowych pobrane na filtry, sorbent oraz kondensat E), Próbki powietrza atmosferycznego, powietrza we wnętrzu pomieszczeń pobranego na filtry i/lub sorbent E)","methodology":"Zawartość:","parameters":[{"name":"polichlorowanych dibenzodioksyn (PCDD)"},{"name":"polichlorowanych dibenzofuranów (PCDF)"},{"name":"polichlorowanych bifenyli (PCB)"}],"technique":"Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)","techniques":["Metoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)"],"computed":[],"activity":"Zawartość:\nZakres:\npolichlorowanych dibenzodioksyn (PCDD)\npolichlorowanych dibenzofuranów (PCDF)\npolichlorowanych bifenyli (PCB)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS)","reference":"Procedura P/01","norm_bases":["Procedura P/01"],"lab_section":"Laboratorium Analiz Śladowych im. Profesora Adama Grochowalskiego","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E), Próbki pochodzenia biologicznego E), Pasze i dodatki paszowe, Produkty rolne E), Gleba E), Osady E), Minerały E), Wyroby chemiczne E), Odpady E), Woda i ścieki E), Próbki gazów pobrane z urządzeń przemysłowych pobrane na filtry, sorbent oraz kondensat E), Próbki powietrza atmosferycznego, powietrza we wnętrzu pomieszczeń pobranego na filtry i/lub sorbent E) Zawartość:\nZakres:\npolichlorowanych dibenzodioksyn (PCDD)\npolichlorowanych dibenzofuranów (PCDF)\npolichlorowanych bifenyli (PCB)\nMetoda chromatografii gazowej z detekcją tandemową spektrometrią mas (GC-MS/MS) Procedura P/01 Zywnosc E), Probki pochodzenia biologicznego E), Pasze i dodatki paszowe, Produkty rolne E), Gleba E), Osady E), Mineraly E), Wyroby chemiczne E), Odpady E), Woda i scieki E), Probki gazow pobrane z urzadzen przemyslowych pobrane na filtry, sorbent oraz kondensat E), Probki powietrza atmosferycznego, powietrza we wnetrzu pomieszczen pobranego na filtry i/lub sorbent E) Zawartosc:\nZakres:\npolichlorowanych dibenzodioksyn (PCDD)\npolichlorowanych dibenzofuranow (PCDF)\npolichlorowanych bifenyli (PCB)\nMetoda chromatografii gazowej z detekcja tandemowa spektrometria mas (GC-MS/MS) Procedura P/01","categories":["water","environment","food"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content:","parameters_en":[{"name":"polychlorinated dibenzodioxins (PCDD)"},{"name":"polychlorinated dibenzofurans (PCDF)"},{"name":"polychlorinated biphenyls (PCB)"}],"regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E), Samples of biological origin E), Feed and feed additives, Agricultural products E), Soil E), Sediments E), Minerals E), Chemical products E), Waste E), Water and wastewater E), Gas samples taken from industrial installations collected on filters, sorbent and condensate E), Ambient air and indoor air samples collected on filters and/or sorbent E) Content: Gas chromatography with tandem mass spectrometry detection (GC-MS/MS) Professor Adam Grochowalski Trace Analysis Laboratory E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. Gas chromatography with tandem mass spectrometry detection (GC-MS/MS) polychlorinated dibenzodioxins (PCDD) polychlorinated dibenzofurans (PCDF) polychlorinated biphenyls (PCB) Procedure P/01","technique_en":"Gas chromatography with tandem mass spectrometry detection (GC-MS/MS)","test_object_en":"Food E), Samples of biological origin E), Feed and feed additives, Agricultural products E), Soil E), Sediments E), Minerals E), Chemical products E), Waste E), Water and wastewater E), Gas samples taken from industrial installations collected on filters, sorbent and condensate E), Ambient air and indoor air samples collected on filters and/or sorbent E)","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E)、生物源样品 E)、饲料和饲料添加剂、农产品 E)、土壤 E)、沉积物 E)、矿物 E)、化工产品 E)、废物 E)、水和废水 E)、从工业设备采集到滤膜、吸附剂上的气体样品以及冷凝液 E)、采集到滤膜和/或吸附剂上的大气和室内空气样品 E) 含量： 气相色谱-串联质谱法（GC-MS/MS） Adam Grochowalski 教授痕量分析实验室 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 气相色谱-串联质谱法（GC-MS/MS） 多氯二苯并二噁英（PCDD） 多氯二苯并呋喃（PCDF） 多氯联苯（PCB） 程序 P/01","technique_zh":"气相色谱-串联质谱法（GC-MS/MS）","methodology_zh":"含量：","lab_section_en":"Professor Adam Grochowalski Trace Analysis Laboratory","techniques_en":["Gas chromatography with tandem mass spectrometry detection (GC-MS/MS)"],"lab_section_de":"Labor für Spurenanalytik „Professor Adam Grochowalski“","methodology_de":"Gehalt:","parameters_de":[{"name":"polychlorierter Dibenzodioxine (PCDD)"},{"name":"polychlorierter Dibenzofurane (PCDF)"},{"name":"polychlorierter Biphenyle (PCB)"}],"regulatory_area_de":"E – Flexibler Akkreditierungsumfang. Die Flexibilität des Umfangs umfasst die im Dokument DA-10 für den Akkreditierungsumfang von Prüflaboratorien genannten Elemente. Die Liste der im Rahmen des flexiblen Akkreditierungsumfangs durchgeführten Tätigkeiten wird von der akkreditierten Stelle öffentlich oder auf Anfrage zugänglich gemacht.","search_de":"Lebensmittel E), Proben biologischen Ursprungs E), Futtermittel und Futtermittelzusatzstoffe, Landwirtschaftliche Erzeugnisse E), Boden E), Sedimente E), Mineralien E), Chemische Erzeugnisse E), Abfälle E), Wasser und Abwasser E), Gasproben aus Industrieanlagen, auf Filter, Sorbens sowie Kondensat genommen E), Proben der Außenluft, der Innenraumluft, auf Filter und/oder Sorbens genommen E) Gehalt: Gaschromatographie mit Tandem-Massenspektrometrie-Detektion (GC-MS/MS) Labor für Spurenanalytik „Professor Adam Grochowalski“ E – Flexibler Akkreditierungsumfang. Die Flexibilität des Umfangs umfasst die im Dokument DA-10 für den Akkreditierungsumfang von Prüflaboratorien genannten Elemente. Die Liste der im Rahmen des flexiblen Akkreditierungsumfangs durchgeführten Tätigkeiten wird von der akkreditierten Stelle öffentlich oder auf Anfrage zugänglich gemacht. Gaschromatographie mit Tandem-Massenspektrometrie-Detektion (GC-MS/MS) polychlorierter Dibenzodioxine (PCDD) polychlorierter Dibenzofurane (PCDF) polychlorierter Biphenyle (PCB) Verfahren P/01","technique_de":"Gaschromatographie mit Tandem-Massenspektrometrie-Detektion (GC-MS/MS)","techniques_de":["Gaschromatographie mit Tandem-Massenspektrometrie-Detektion (GC-MS/MS)"],"test_object_de":"Lebensmittel E), Proben biologischen Ursprungs E), Futtermittel und Futtermittelzusatzstoffe, Landwirtschaftliche Erzeugnisse E), Boden E), Sedimente E), Mineralien E), Chemische Erzeugnisse E), Abfälle E), Wasser und Abwasser E), Gasproben aus Industrieanlagen, auf Filter, Sorbens sowie Kondensat genommen E), Proben der Außenluft, der Innenraumluft, auf Filter und/oder Sorbens genommen E)","lab_section_zh":"Adam Grochowalski 教授痕量分析实验室","parameters_zh":[{"name":"多氯二苯并二噁英（PCDD）"},{"name":"多氯二苯并呋喃（PCDF）"},{"name":"多氯联苯（PCB）"}],"techniques_zh":["气相色谱-串联质谱法（GC-MS/MS）"],"test_object_zh":"食品 E)、生物源样品 E)、饲料和饲料添加剂、农产品 E)、土壤 E)、沉积物 E)、矿物 E)、化工产品 E)、废物 E)、水和废水 E)、从工业设备采集到滤膜、吸附剂上的气体样品以及冷凝液 E)、采集到滤膜和/或吸附剂上的大气和室内空气样品 E)","reference_en":"Procedure P/01","reference_de":"Verfahren P/01","reference_zh":"程序 P/01","methodology_cs":"Obsah:","regulatory_area_cs":"E – Flexibilní rozsah akreditace. Flexibilita rozsahu zahrnuje prvky uvedené v dokumentu DA-10 pro rozsah akreditace zkušebních laboratoří. Seznam činností prováděných v rámci flexibilního rozsahu akreditace zpřístupňuje akreditovaný subjekt veřejně nebo na vyžádání.","search_cs":"Potraviny E), Vzorky biologického původu E), Krmiva a doplňkové látky v krmivech, Zemědělské produkty E), Půda E), Sedimenty E), Minerály E), Chemické výrobky E), Odpady E), Voda a odpadní vody E), Vzorky plynů odebrané z průmyslových zařízení na filtry, sorbent a kondenzát E), Vzorky venkovního ovzduší a vnitřního ovzduší odebrané na filtry a/nebo sorbent E) Obsah: Metoda plynové chromatografie s tandemovou hmotnostně spektrometrickou detekcí (GC-MS/MS) Laboratoř stopové analýzy profesora Adama Grochowalského E – Flexibilní rozsah akreditace. Flexibilita rozsahu zahrnuje prvky uvedené v dokumentu DA-10 pro rozsah akreditace zkušebních laboratoří. Seznam činností prováděných v rámci flexibilního rozsahu akreditace zpřístupňuje akreditovaný subjekt veřejně nebo na vyžádání. Metoda plynové chromatografie s tandemovou hmotnostně spektrometrickou detekcí (GC-MS/MS) polychlorovaných dibenzodioxinů (PCDD) polychlorovaných dibenzofuranů (PCDF) polychlorovaných bifenylů (PCB) Postup P/01","technique_cs":"Metoda plynové chromatografie s tandemovou hmotnostně spektrometrickou detekcí (GC-MS/MS)","techniques_cs":["Metoda plynové chromatografie s tandemovou hmotnostně spektrometrickou detekcí (GC-MS/MS)"],"lab_section_cs":"Laboratoř stopové analýzy profesora Adama Grochowalského","parameters_cs":[{"name":"polychlorovaných dibenzodioxinů (PCDD)"},{"name":"polychlorovaných dibenzofuranů (PCDF)"},{"name":"polychlorovaných bifenylů (PCB)"}],"reference_cs":"Postup P/01","test_object_cs":"Potraviny E), Vzorky biologického původu E), Krmiva a doplňkové látky v krmivech, Zemědělské produkty E), Půda E), Sedimenty E), Minerály E), Chemické výrobky E), Odpady E), Voda a odpadní vody E), Vzorky plynů odebrané z průmyslových zařízení na filtry, sorbent a kondenzát E), Vzorky venkovního ovzduší a vnitřního ovzduší odebrané na filtry a/nebo sorbent E)"}],"has_pdf":true}