🇵🇱 OKRĘGOWA SPÓŁDZIELNIA MLECZARSKA W PIĄTNICY PL

PCA AB 718 • Piątnica, Poland • 7 methods

Food & beveragesMicrobiology

OKRĘGOWA SPÓŁDZIELNIA MLECZARSKA W PIĄTNICY is a laboratory accredited by PCA under number AB 718 (Piątnica, Poland). Its accreditation scope covers 7 test methods in the following areas: Food & beverages, Microbiology. Test objects include: Raw milk. Most frequently used techniques: Flow cytometry method, Infrared spectrometry method, Receptor method.

At a glance

  • Accreditation number: PCA AB 718
  • Methods in scope: 7
  • Types of test objects: 1
  • Techniques used: 3
  • City: Piątnica, Poland
Accreditation number
AB 718
Accreditation body
PCA
Address
LABORATORIUM KONTROLI JAKOŚCI, ul. Forteczna 3, 18-421 Piątnica
City
Piątnica, Poland

What this laboratory tests (1)

Analytical techniques used (3)

Laboratory sections (2)

Laboratory locations

Accreditation scope — test methods (7)

No. Test object Methodology / Parameters Technique Reference document
Quality Control Laboratory – raw material assessment laboratory
1 Raw milk Total viable count
Range (2000 – 3 000 000) jtk/ml
Flow cytometry method Instrukcja badawcza PL/bc 01-0 Wersja 2 z dnia 02.12.2025 r. z zastosowaniem aparatu BactoCount IBC 3.0
2 Raw milk Total viable count
Range (2000 – 3 000 000) jtk/ml
Flow cytometry method Instrukcja badawcza PL/bc 02-0 Wersja 1 z dnia 08.01.2026 r. z zastosowaniem aparatu BactoCount IBC M 3.0
3 Raw milk Somatic cell count
Range (1000 – 2 000 000) komórek/ml
Flow cytometry method PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaCount FC
4 Raw milk Fat content
Range (1,50 – 7,00) %
Infrared spectrometry method PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT
5 Raw milk Protein content
Range (2,00 – 5,00) %
Infrared spectrometry method PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT
6 Raw milk Detection of the presence of β-lactam and tetracycline antibiotics Receptor method Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2
Production Plant in Ostrołęka; Quality Control Laboratory – raw material assessment laboratory
7 Raw milk Detection of the presence of β-lactam and tetracycline antibiotics Receptor method Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2

Reference standards (5)

Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2
Instrukcja badawcza PL/bc 01-0 Wersja 2 z dnia 02.12.2025 r. z zastosowaniem aparatu BactoCount IBC 3.0
Instrukcja badawcza PL/bc 02-0 Wersja 1 z dnia 08.01.2026 r. z zastosowaniem aparatu BactoCount IBC M 3.0
PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaCount FC
PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT