{"lab":{"_id":"69ad52a3de79e566650fb3a2","accr_number":"AB 718","country":"PL","accr_body":"PCA","address":"LABORATORIUM KONTROLI JAKOŚCI, ul. Forteczna 3, 18-421 Piątnica","categories":["food","microbiology"],"city":"Piątnica","imported_at":"2026-03-08T10:42:43.265Z","methods_count":7,"name":"OKRĘGOWA SPÓŁDZIELNIA MLECZARSKA W PIĄTNICY","parse_status":"parsed","parse_version":2,"pdf_files":["AB_718.pdf"],"scope_summary":"","search_text":"okręgowa spółdzielnia mleczarska w piątnicy laboratorium kontroli jakości, ul. forteczna 3, 18-421 piątnica other food microbiology pharma","status":"active","updated_at":"2026-03-08T14:51:37.022Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:10:34.061Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20718,podmiot.html","fields_of_testing":[{"codes":"C/22","pl":"Badania chemiczne żywności","en":"Chemical tests of food"},{"codes":"B/22","pl":"Badania biochemiczne żywności","en":"Biochemical tests of food"},{"codes":"K/22","pl":"Badania mikrobiologiczne żywności","en":"Microbiological tests of food"}],"issue":{"no":"20","date":"26.06.2026"},"parse_date":"2026-08-13T08:10:34.061Z","parse_source":"agent-claude-code","map_coord":[53.199751,22.093833],"map_geo":"nominatim-street","lab_locations":[{"name":"LABORATORIUM KONTROLI JAKOŚCI","address":"ul. Forteczna 3","city":null,"postal":null},{"name":"Laboratorium Kontroli Jakości – pracownia oceny surowca","address":"ul. Forteczna 3, 18-421 Piątnica","city":"Piątnica","postal":"18-421"},{"name":"Zakład Produkcyjny w Ostrołęce","address":"ul. Ławska 1, 07-400 Ostrołęka","city":"Ostrołęka","postal":"07-400"},{"name":"Zakład Produkcyjny w Ostrołęce; Laboratorium Kontroli Jakości – pracownia oceny surowca","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/2ea32a841b47a9a927bae1813062f44a/AB%20718.pdf","has_en":true,"category_counts":{"food":7,"microbiology":2},"category_scores":{"food":5.44,"microbiology":0.44},"has_zh":true,"lab_locations_zh":[{"name":"LABORATORIUM KONTROLI JAKOŚCI","address":"ul. Forteczna 3","city":null,"postal":null},{"name":"质量控制实验室 － 原料评价检验室","address":"ul. Forteczna 3, 18-421 Piątnica","city":"Piątnica","postal":"18-421"},{"name":"Zakład Produkcyjny w Ostrołęce","address":"ul. Ławska 1, 07-400 Ostrołęka","city":"Ostrołęka","postal":"07-400"},{"name":"Zakład Produkcyjny w Ostrołęce; Laboratorium Kontroli Jakości – pracownia oceny surowca","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7bfa0636ba417e41c141","lab_id":"69ad52a3de79e566650fb3a2","country":"PL","accr_number":"AB 718","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Ogólna liczba drobnoustrojów","parameters":[{"name":"Zakres","range":"(2000 – 3 000 000) jtk/ml"}],"technique":"Metoda cytometrii przepływowej","techniques":["Metoda cytometrii przepływowej"],"computed":[],"activity":"Ogólna liczba drobnoustrojów\nZakres (2000 – 3 000 000) jtk/ml\nMetoda cytometrii przepływowej","reference":"Instrukcja badawcza PL/bc 01-0 Wersja 2 z dnia 02.12.2025 r. z zastosowaniem aparatu BactoCount IBC 3.0","norm_bases":["Instrukcja badawcza PL/bc 01-0 Wersja 2 z dnia 02.12.2025 r. z zastosowaniem aparatu BactoCount IBC 3.0"],"lab_section":"Laboratorium Kontroli Jakości – pracownia oceny surowca","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Ogólna liczba drobnoustrojów\nZakres (2000 – 3 000 000) jtk/ml\nMetoda cytometrii przepływowej Instrukcja badawcza PL/bc 01-0 Wersja 2 z dnia 02.12.2025 r. z zastosowaniem aparatu BactoCount IBC 3.0 Mleko surowe Ogolna liczba drobnoustrojow\nZakres (2000 – 3 000 000) jtk/ml\nMetoda cytometrii przeplywowej Instrukcja badawcza PL/bc 01-0 Wersja 2 z dnia 02.12.2025 r. z zastosowaniem aparatu BactoCount IBC 3.0","categories":["food","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control Laboratory – raw material assessment laboratory","methodology_en":"Total viable count","parameters_en":[{"name":"Range","range":"(2000 – 3 000 000) jtk/ml"}],"search_en":"Raw milk Total viable count Flow cytometry method Quality Control Laboratory – raw material assessment laboratory Range Instrukcja badawcza PL/bc 01-0 Wersja 2 z dnia 02.12.2025 r. z zastosowaniem aparatu BactoCount IBC 3.0","technique_en":"Flow cytometry method","test_object_en":"Raw milk","methodology_zh":"微生物总数","parameters_zh":[{"name":"范围","range":"(2000 – 3 000 000) jtk/ml"}],"search_zh":"生乳 微生物总数 流式细胞术 质量控制实验室 － 原料评价检验室 范围 Instrukcja badawcza PL/bc 01-0 Wersja 2 z dnia 02.12.2025 r. z zastosowaniem aparatu BactoCount IBC 3.0","technique_zh":"流式细胞术","test_object_zh":"生乳","lab_section_zh":"质量控制实验室 － 原料评价检验室"},{"_id":"6a7d7bfa0636ba417e41c142","lab_id":"69ad52a3de79e566650fb3a2","country":"PL","accr_number":"AB 718","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Ogólna liczba drobnoustrojów","parameters":[{"name":"Zakres","range":"(2000 – 3 000 000) jtk/ml"}],"technique":"Metoda cytometrii przepływowej","techniques":["Metoda cytometrii przepływowej"],"computed":[],"activity":"Ogólna liczba drobnoustrojów\nZakres (2000 – 3 000 000) jtk/ml\nMetoda cytometrii przepływowej","reference":"Instrukcja badawcza PL/bc 02-0 Wersja 1 z dnia 08.01.2026 r. z zastosowaniem aparatu BactoCount IBC M 3.0","norm_bases":["Instrukcja badawcza PL/bc 02-0 Wersja 1 z dnia 08.01.2026 r. z zastosowaniem aparatu BactoCount IBC M 3.0"],"lab_section":"Laboratorium Kontroli Jakości – pracownia oceny surowca","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Ogólna liczba drobnoustrojów\nZakres (2000 – 3 000 000) jtk/ml\nMetoda cytometrii przepływowej Instrukcja badawcza PL/bc 02-0 Wersja 1 z dnia 08.01.2026 r. z zastosowaniem aparatu BactoCount IBC M 3.0 Mleko surowe Ogolna liczba drobnoustrojow\nZakres (2000 – 3 000 000) jtk/ml\nMetoda cytometrii przeplywowej Instrukcja badawcza PL/bc 02-0 Wersja 1 z dnia 08.01.2026 r. z zastosowaniem aparatu BactoCount IBC M 3.0","categories":["food","microbiology"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control Laboratory – raw material assessment laboratory","methodology_en":"Total viable count","parameters_en":[{"name":"Range","range":"(2000 – 3 000 000) jtk/ml"}],"search_en":"Raw milk Total viable count Flow cytometry method Quality Control Laboratory – raw material assessment laboratory Range Instrukcja badawcza PL/bc 02-0 Wersja 1 z dnia 08.01.2026 r. z zastosowaniem aparatu BactoCount IBC M 3.0","technique_en":"Flow cytometry method","test_object_en":"Raw milk","methodology_zh":"微生物总数","parameters_zh":[{"name":"范围","range":"(2000 – 3 000 000) jtk/ml"}],"search_zh":"生乳 微生物总数 流式细胞术 质量控制实验室 － 原料评价检验室 范围 Instrukcja badawcza PL/bc 02-0 Wersja 1 z dnia 08.01.2026 r. z zastosowaniem aparatu BactoCount IBC M 3.0","technique_zh":"流式细胞术","test_object_zh":"生乳","lab_section_zh":"质量控制实验室 － 原料评价检验室"},{"_id":"6a7d7bfa0636ba417e41c143","lab_id":"69ad52a3de79e566650fb3a2","country":"PL","accr_number":"AB 718","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Liczba komórek somatycznych","parameters":[{"name":"Zakres","range":"(1000 – 2 000 000) komórek/ml"}],"technique":"Metoda cytometrii przepływowej","techniques":["Metoda cytometrii przepływowej"],"computed":[],"activity":"Liczba komórek somatycznych\nZakres (1000 – 2 000 000) komórek/ml\nMetoda cytometrii przepływowej","reference":"PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaCount FC","norm_bases":["PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaCount FC"],"lab_section":"Laboratorium Kontroli Jakości – pracownia oceny surowca","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Liczba komórek somatycznych\nZakres (1000 – 2 000 000) komórek/ml\nMetoda cytometrii przepływowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaCount FC Mleko surowe Liczba komorek somatycznych\nZakres (1000 – 2 000 000) komorek/ml\nMetoda cytometrii przeplywowej PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaCount FC","categories":["food"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control Laboratory – raw material assessment laboratory","methodology_en":"Somatic cell count","parameters_en":[{"name":"Range","range":"(1000 – 2 000 000) komórek/ml"}],"search_en":"Raw milk Somatic cell count Flow cytometry method Quality Control Laboratory – raw material assessment laboratory Range PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaCount FC","technique_en":"Flow cytometry method","test_object_en":"Raw milk","methodology_zh":"体细胞计数","parameters_zh":[{"name":"范围","range":"(1000 – 2 000 000) komórek/ml"}],"search_zh":"生乳 体细胞计数 流式细胞术 质量控制实验室 － 原料评价检验室 范围 PN-EN ISO 13366-2:2007 z zastosowaniem aparatu SomaCount FC","technique_zh":"流式细胞术","test_object_zh":"生乳","lab_section_zh":"质量控制实验室 － 原料评价检验室"},{"_id":"6a7d7bfa0636ba417e41c144","lab_id":"69ad52a3de79e566650fb3a2","country":"PL","accr_number":"AB 718","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Zawartość tłuszczu","parameters":[{"name":"Zakres","range":"(1,50 – 7,00) %"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"computed":[],"activity":"Zawartość tłuszczu\nZakres (1,50 – 7,00) %\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT"],"lab_section":"Laboratorium Kontroli Jakości – pracownia oceny surowca","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Zawartość tłuszczu\nZakres (1,50 – 7,00) %\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT Mleko surowe Zawartosc tluszczu\nZakres (1,50 – 7,00) %\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","categories":["food"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control Laboratory – raw material assessment laboratory","methodology_en":"Fat content","parameters_en":[{"name":"Range","range":"(1,50 – 7,00) %"}],"search_en":"Raw milk Fat content Infrared spectrometry method Quality Control Laboratory – raw material assessment laboratory Range PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","technique_en":"Infrared spectrometry method","test_object_en":"Raw milk","methodology_zh":"脂肪含量","parameters_zh":[{"name":"范围","range":"(1,50 – 7,00) %"}],"search_zh":"生乳 脂肪含量 红外光谱法 质量控制实验室 － 原料评价检验室 范围 PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","technique_zh":"红外光谱法","test_object_zh":"生乳","lab_section_zh":"质量控制实验室 － 原料评价检验室"},{"_id":"6a7d7bfa0636ba417e41c145","lab_id":"69ad52a3de79e566650fb3a2","country":"PL","accr_number":"AB 718","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Zawartość białka","parameters":[{"name":"Zakres","range":"(2,00 – 5,00) %"}],"technique":"Metoda spektrometrii w podczerwieni","techniques":["Metoda spektrometrii w podczerwieni"],"computed":[],"activity":"Zawartość białka\nZakres (2,00 – 5,00) %\nMetoda spektrometrii w podczerwieni","reference":"PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","norm_bases":["PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT"],"lab_section":"Laboratorium Kontroli Jakości – pracownia oceny surowca","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Zawartość białka\nZakres (2,00 – 5,00) %\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT Mleko surowe Zawartosc bialka\nZakres (2,00 – 5,00) %\nMetoda spektrometrii w podczerwieni PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","categories":["food"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control Laboratory – raw material assessment laboratory","methodology_en":"Protein content","parameters_en":[{"name":"Range","range":"(2,00 – 5,00) %"}],"search_en":"Raw milk Protein content Infrared spectrometry method Quality Control Laboratory – raw material assessment laboratory Range PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","technique_en":"Infrared spectrometry method","test_object_en":"Raw milk","methodology_zh":"蛋白质含量","parameters_zh":[{"name":"范围","range":"(2,00 – 5,00) %"}],"search_zh":"生乳 蛋白质含量 红外光谱法 质量控制实验室 － 原料评价检验室 范围 PN-ISO 9622:2015-09 z zastosowaniem aparatu DairySpec FT","technique_zh":"红外光谱法","test_object_zh":"生乳","lab_section_zh":"质量控制实验室 － 原料评价检验室"},{"_id":"6a7d7bfa0636ba417e41c146","lab_id":"69ad52a3de79e566650fb3a2","country":"PL","accr_number":"AB 718","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Wykrywanie obecności antybiotyków βlaktamów i tetracyklin","parameters":[],"technique":"Metoda receptorowa","techniques":["Metoda receptorowa"],"computed":[],"activity":"Wykrywanie obecności antybiotyków βlaktamów i tetracyklin\nMetoda receptorowa","reference":"Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2","norm_bases":["Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2"],"lab_section":"Laboratorium Kontroli Jakości – pracownia oceny surowca","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Wykrywanie obecności antybiotyków βlaktamów i tetracyklin\nMetoda receptorowa Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2 Mleko surowe Wykrywanie obecnosci antybiotykow βlaktamow i tetracyklin\nMetoda receptorowa Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcje producenta testu Charm MRLBLRFTET2","categories":["food"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Quality Control Laboratory – raw material assessment laboratory","methodology_en":"Detection of the presence of β-lactam and tetracycline antibiotics","search_en":"Raw milk Detection of the presence of β-lactam and tetracycline antibiotics Receptor method Quality Control Laboratory – raw material assessment laboratory Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2","technique_en":"Receptor method","test_object_en":"Raw milk","search_zh":"生乳 受体法 质量控制实验室 － 原料评价检验室 Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2","technique_zh":"受体法","test_object_zh":"生乳","lab_section_zh":"质量控制实验室 － 原料评价检验室"},{"_id":"6a7d7bfa0636ba417e41c147","lab_id":"69ad52a3de79e566650fb3a2","country":"PL","accr_number":"AB 718","accr_body":"PCA","test_object":"Mleko surowe","methodology":"Wykrywanie obecności antybiotyków βlaktamów i tetracyklin","parameters":[],"technique":"Metoda receptorowa","techniques":["Metoda receptorowa"],"computed":[],"activity":"Wykrywanie obecności antybiotyków βlaktamów i tetracyklin\nMetoda receptorowa","reference":"Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2","norm_bases":["Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2"],"lab_section":"Zakład Produkcyjny w Ostrołęce; Laboratorium Kontroli Jakości – pracownia oceny surowca","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko surowe Wykrywanie obecności antybiotyków βlaktamów i tetracyklin\nMetoda receptorowa Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2 Mleko surowe Wykrywanie obecnosci antybiotykow βlaktamow i tetracyklin\nMetoda receptorowa Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcje producenta testu Charm MRLBLRFTET2","categories":["food"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Production Plant in Ostrołęka; Quality Control Laboratory – raw material assessment laboratory","methodology_en":"Detection of the presence of β-lactam and tetracycline antibiotics","search_en":"Raw milk Detection of the presence of β-lactam and tetracycline antibiotics Receptor method Production Plant in Ostrołęka; Quality Control Laboratory – raw material assessment laboratory Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2","technique_en":"Receptor method","test_object_en":"Raw milk","search_zh":"生乳 受体法 Instrukcja badawcza PJ-pos 12-0 wersja 2 z 08.01.2024 w oparciu o instrukcję producenta testu Charm MRLBLRFTET2","technique_zh":"受体法","test_object_zh":"生乳"}],"has_pdf":true}