🇵🇱 WOJSKOWA AKADEMIA TECHNICZNA PL

PCA AB 693 • Warszawa, Poland • 7 methods

Electronics & EMC

WOJSKOWA AKADEMIA TECHNICZNA is a laboratory accredited by PCA under number AB 693 (Warszawa, Poland). Its accreditation scope covers 7 test methods in the following areas: Electronics & EMC. Test objects include: Military equipment, Information technology equipment, Multimedia equipment.

At a glance

  • Accreditation number: PCA AB 693
  • Methods in scope: 7
  • Types of test objects: 2
  • City: Warszawa, Poland
Accreditation number
AB 693
Accreditation body
PCA
Address
im. Jarosława Dąbrowskiego, LABORATORIUM KOMPATYBILNOŚCI ELEKTROMAGNETYCZNEJ, WYDZIAŁU ELEKTRONIKI WAT, AB xxx ul. Gen. Sylwestra Kaliskiego 2
City
Warszawa, Poland

What this laboratory tests (2)

Accreditation scope — test methods (7)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Information technology equipment, Multimedia equipment Level of radiated disturbances in the frequency range: (1 - 6) GHz PN-EN 55022:2011 p.10 | EN 55022:2010 p.10
2 Information technology equipment, Multimedia equipment Immunity to continuous disturbances from RF electromagnetic field, scanning test 80 MHz - 1 GHz PN-EN 61000-4-3:2021-06 | PN-EN 55035:2017-09 p.5 | PN-EN 55024:2011 p.4.2.3 | PN-EN 55024:2011/A1:2015-08
3 Military equipment Level of radiated disturbances, electric field in the frequency range: 10 kHz - 18 GHz NO-06-A500:2012, p.3.14 (procedura PRE-02) | MIL-STD-461F p. 5.17 (RE102)
4 Military equipment Level of conducted disturbances on power supply lines in the frequency range: 10 kHz - 10 MHz NO-06-A500:2012, p.3.2 (procedura PCE-02) | MIL-STD-461F p. 5.5 (CE102)
5 Military equipment Immunity to radiated disturbances, electric fields in the frequency range: (80 - 2500) MHz NO-06-A500:2012, p.3.17 (procedura PRS-02) | MIL-STD-461F p. 5.20 (RS103)
6 Military equipment Level of radiated disturbances, magnetic field in the frequency range: 100 Hz - 100 kHz NO-06-A500:2012, p.3.13 (procedura PRE-01) | MIL-STD-461F p. 5.16 (RE101)
7 Military equipment Level of radiated disturbances, electric field, produced by generating sets in the frequency range: 2 MHz - 18 GHz NO-61-A208:2013 p. 2.1.15, 3.14 NO-06-A500:2012 p. 3.14 (procedura PRE-02)

Reference standards (15)

EN 55022:2010 p.10
MIL-STD-461F p. 5.16 (RE101)
MIL-STD-461F p. 5.17 (RE102)
MIL-STD-461F p. 5.20 (RS103)
MIL-STD-461F p. 5.5 (CE102)
NO-06-A500:2012, p.3.13 (procedura PRE-01)
NO-06-A500:2012, p.3.14 (procedura PRE-02)
NO-06-A500:2012, p.3.17 (procedura PRS-02)
NO-06-A500:2012, p.3.2 (procedura PCE-02)
NO-61-A208:2013 p. 2.1.15, 3.14 NO-06-A500:2012 p. 3.14 (procedura PRE-02)
PN-EN 55022:2011 p.10
PN-EN 55024:2011 p.4.2.3
PN-EN 55024:2011/A1:2015-08
PN-EN 55035:2017-09 p.5
PN-EN 61000-4-3:2021-06