{"lab":{"_id":"69ad52a3de79e566650fb384","accr_number":"AB 693","country":"PL","accr_body":"PCA","address":"im. Jarosława Dąbrowskiego, LABORATORIUM KOMPATYBILNOŚCI ELEKTROMAGNETYCZNEJ, WYDZIAŁU ELEKTRONIKI WAT, AB xxx                                                            ul. Gen. Sylwestra Kaliskiego 2","categories":["other"],"city":"Warszawa","imported_at":"2026-03-08T10:42:43.265Z","methods_count":7,"name":"WOJSKOWA AKADEMIA TECHNICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_693.pdf"],"scope_summary":"","search_text":"wojskowa akademia techniczna im. jarosława dąbrowskiego, laboratorium kompatybilności elektromagnetycznej, wydziału elektroniki wat, ab xxx                                                            ul. gen. sylwestra kaliskiego 2 other pharma electronics water construction","status":"active","updated_at":"2026-03-08T14:51:35.639Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:35.639Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20693,podmiot.html","fields_of_testing":[{"codes":"E/6, E/53; E/54; E/15","pl":"Badania elektryczne i elektroniczne wyrobów i wyposażenia elektrycznego, telekomunikacyjnego, elektronicznego oraz wyposażenia wojskowego","en":"Electric and electronic tests of electrical, telecommunication and electronic products and equipment and military equipment"},{"codes":"F/6; F/53; F/54; F/15","pl":"Badania kompatybilności elektromagnetycznej (EMC) wyrobów i wyposażenia elektrycznego, telekomunikacyjnego, elektronicznego oraz wyposażenia wojskowego","en":"Electromagnetic compatibility (EMC) tests of electrical, telecommunication and electronic products and equipment and military equipment"}],"issue":{"no":"20","date":"29.01.2026"},"parse_date":"2026-07-20T07:09:48.120Z","parse_source":"script-pdfplumber","map_coord":[52.250046,20.901794],"map_geo":"nominatim-street","has_en":true,"category_counts":{"other":7},"category_scores":{"other":7},"has_zh":true},"methods":[{"_id":"6a5dc9bcf1c10c8ce825e1b4","lab_id":"69ad52a3de79e566650fb384","country":"PL","accr_number":"AB 693","accr_body":"PCA","test_object":"Urządzenia informatyczne, Urządzenia multimedialne","test_object_en":"Information technology equipment, Multimedia equipment","methodology":"Poziom zaburzeń promieniowanych w zakresie częstotliwości: (1 - 6) GHz","methodology_en":"Level of radiated disturbances in the frequency range: (1 - 6) GHz","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom zaburzeń promieniowanych w zakresie częstotliwości: (1 - 6) GHz","reference":"PN-EN 55022:2011 p.10 | EN 55022:2010 p.10","norm_bases":["PN-EN 55022:2011 p.10","EN 55022:2010 p.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia informatyczne, Urządzenia multimedialne Poziom zaburzeń promieniowanych w zakresie częstotliwości: (1 - 6) GHz PN-EN 55022:2011 p.10 | EN 55022:2010 p.10 Urzadzenia informatyczne, Urzadzenia multimedialne Poziom zaburzen promieniowanych w zakresie czestotliwosci: (1 - 6) GHz PN-EN 55022:2011 p.10 | EN 55022:2010 p.10","categories":["other"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Information technology equipment, Multimedia equipment Level of radiated disturbances in the frequency range: (1 - 6) GHz PN-EN 55022:2011 p.10 | EN 55022:2010 p.10"},{"_id":"6a5dc9bcf1c10c8ce825e1b5","lab_id":"69ad52a3de79e566650fb384","country":"PL","accr_number":"AB 693","accr_body":"PCA","test_object":"Urządzenia informatyczne, Urządzenia multimedialne","test_object_en":"Information technology equipment, Multimedia equipment","methodology":"Odporność na zaburzenia ciągłe od pola elektromagnetycznego RF, badanie ze skanowaniem 80 MHz - 1 GHz","methodology_en":"Immunity to continuous disturbances from RF electromagnetic field, scanning test 80 MHz - 1 GHz","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na zaburzenia ciągłe od pola elektromagnetycznego RF, badanie ze skanowaniem 80 MHz - 1 GHz","reference":"PN-EN 61000-4-3:2021-06 | PN-EN 55035:2017-09 p.5 | PN-EN 55024:2011 p.4.2.3 | PN-EN 55024:2011/A1:2015-08","norm_bases":["PN-EN 61000-4-3:2021-06","PN-EN 55035:2017-09 p.5","PN-EN 55024:2011 p.4.2.3","PN-EN 55024:2011/A1:2015-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Urządzenia informatyczne, Urządzenia multimedialne Odporność na zaburzenia ciągłe od pola elektromagnetycznego RF, badanie ze skanowaniem 80 MHz - 1 GHz PN-EN 61000-4-3:2021-06 | PN-EN 55035:2017-09 p.5 | PN-EN 55024:2011 p.4.2.3 | PN-EN 55024:2011/A1:2015-08 Urzadzenia informatyczne, Urzadzenia multimedialne Odpornosc na zaburzenia ciagle od pola elektromagnetycznego RF, badanie ze skanowaniem 80 MHz - 1 GHz PN-EN 61000-4-3:2021-06 | PN-EN 55035:2017-09 p.5 | PN-EN 55024:2011 p.4.2.3 | PN-EN 55024:2011/A1:2015-08","categories":["other"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Information technology equipment, Multimedia equipment Immunity to continuous disturbances from RF electromagnetic field, scanning test 80 MHz - 1 GHz PN-EN 61000-4-3:2021-06 | PN-EN 55035:2017-09 p.5 | PN-EN 55024:2011 p.4.2.3 | PN-EN 55024:2011/A1:2015-08"},{"_id":"6a5dc9bcf1c10c8ce825e1b6","lab_id":"69ad52a3de79e566650fb384","country":"PL","accr_number":"AB 693","accr_body":"PCA","test_object":"Wyposażenie wojskowe","test_object_en":"Military equipment","methodology":"Poziom zaburzeń promieniowanych, pole elektryczne w zakresie częstotliwości: 10 kHz - 18 GHz","methodology_en":"Level of radiated disturbances, electric field in the frequency range: 10 kHz - 18 GHz","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom zaburzeń promieniowanych, pole elektryczne w zakresie częstotliwości: 10 kHz - 18 GHz","reference":"NO-06-A500:2012, p.3.14 (procedura PRE-02) | MIL-STD-461F p. 5.17 (RE102)","norm_bases":["NO-06-A500:2012, p.3.14 (procedura PRE-02)","MIL-STD-461F p. 5.17 (RE102)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe Poziom zaburzeń promieniowanych, pole elektryczne w zakresie częstotliwości: 10 kHz - 18 GHz NO-06-A500:2012, p.3.14 (procedura PRE-02) | MIL-STD-461F p. 5.17 (RE102) Wyposazenie wojskowe Poziom zaburzen promieniowanych, pole elektryczne w zakresie czestotliwosci: 10 kHz - 18 GHz NO-06-A500:2012, p.3.14 (procedura PRE-02) | MIL-STD-461F p. 5.17 (RE102)","categories":["other"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Military equipment Level of radiated disturbances, electric field in the frequency range: 10 kHz - 18 GHz NO-06-A500:2012, p.3.14 (procedura PRE-02) | MIL-STD-461F p. 5.17 (RE102)","search_zh":"军用装备 NO-06-A500:2012, p.3.14 (procedura PRE-02) | MIL-STD-461F p. 5.17 (RE102)","test_object_zh":"军用装备"},{"_id":"6a5dc9bcf1c10c8ce825e1b7","lab_id":"69ad52a3de79e566650fb384","country":"PL","accr_number":"AB 693","accr_body":"PCA","test_object":"Wyposażenie wojskowe","test_object_en":"Military equipment","methodology":"Poziom zaburzeń przewodzonych w przewodach zasilania w zakresie częstotliwości: 10 kHz - 10 MHz","methodology_en":"Level of conducted disturbances on power supply lines in the frequency range: 10 kHz - 10 MHz","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom zaburzeń przewodzonych w przewodach zasilania w zakresie częstotliwości: 10 kHz - 10 MHz","reference":"NO-06-A500:2012, p.3.2 (procedura PCE-02) | MIL-STD-461F p. 5.5 (CE102)","norm_bases":["NO-06-A500:2012, p.3.2 (procedura PCE-02)","MIL-STD-461F p. 5.5 (CE102)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe Poziom zaburzeń przewodzonych w przewodach zasilania w zakresie częstotliwości: 10 kHz - 10 MHz NO-06-A500:2012, p.3.2 (procedura PCE-02) | MIL-STD-461F p. 5.5 (CE102) Wyposazenie wojskowe Poziom zaburzen przewodzonych w przewodach zasilania w zakresie czestotliwosci: 10 kHz - 10 MHz NO-06-A500:2012, p.3.2 (procedura PCE-02) | MIL-STD-461F p. 5.5 (CE102)","categories":["other"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Military equipment Level of conducted disturbances on power supply lines in the frequency range: 10 kHz - 10 MHz NO-06-A500:2012, p.3.2 (procedura PCE-02) | MIL-STD-461F p. 5.5 (CE102)","search_zh":"军用装备 NO-06-A500:2012, p.3.2 (procedura PCE-02) | MIL-STD-461F p. 5.5 (CE102)","test_object_zh":"军用装备"},{"_id":"6a5dc9bcf1c10c8ce825e1b8","lab_id":"69ad52a3de79e566650fb384","country":"PL","accr_number":"AB 693","accr_body":"PCA","test_object":"Wyposażenie wojskowe","test_object_en":"Military equipment","methodology":"Odporność na narażenia promieniowane, pola elektryczne w zakresie częstotliwości: (80 - 2500) MHz","methodology_en":"Immunity to radiated disturbances, electric fields in the frequency range: (80 - 2500) MHz","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Odporność na narażenia promieniowane, pola elektryczne w zakresie częstotliwości: (80 - 2500) MHz","reference":"NO-06-A500:2012, p.3.17 (procedura PRS-02) | MIL-STD-461F p. 5.20 (RS103)","norm_bases":["NO-06-A500:2012, p.3.17 (procedura PRS-02)","MIL-STD-461F p. 5.20 (RS103)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe Odporność na narażenia promieniowane, pola elektryczne w zakresie częstotliwości: (80 - 2500) MHz NO-06-A500:2012, p.3.17 (procedura PRS-02) | MIL-STD-461F p. 5.20 (RS103) Wyposazenie wojskowe Odpornosc na narazenia promieniowane, pola elektryczne w zakresie czestotliwosci: (80 - 2500) MHz NO-06-A500:2012, p.3.17 (procedura PRS-02) | MIL-STD-461F p. 5.20 (RS103)","categories":["other"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Military equipment Immunity to radiated disturbances, electric fields in the frequency range: (80 - 2500) MHz NO-06-A500:2012, p.3.17 (procedura PRS-02) | MIL-STD-461F p. 5.20 (RS103)","search_zh":"军用装备 NO-06-A500:2012, p.3.17 (procedura PRS-02) | MIL-STD-461F p. 5.20 (RS103)","test_object_zh":"军用装备"},{"_id":"6a5dc9bcf1c10c8ce825e1b9","lab_id":"69ad52a3de79e566650fb384","country":"PL","accr_number":"AB 693","accr_body":"PCA","test_object":"Wyposażenie wojskowe","test_object_en":"Military equipment","methodology":"Poziom zaburzeń promieniowanych, pole magnetyczne w zakresie częstotliwości: 100 Hz - 100 kHz","methodology_en":"Level of radiated disturbances, magnetic field in the frequency range: 100 Hz - 100 kHz","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom zaburzeń promieniowanych, pole magnetyczne w zakresie częstotliwości: 100 Hz - 100 kHz","reference":"NO-06-A500:2012, p.3.13 (procedura PRE-01) | MIL-STD-461F p. 5.16 (RE101)","norm_bases":["NO-06-A500:2012, p.3.13 (procedura PRE-01)","MIL-STD-461F p. 5.16 (RE101)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe Poziom zaburzeń promieniowanych, pole magnetyczne w zakresie częstotliwości: 100 Hz - 100 kHz NO-06-A500:2012, p.3.13 (procedura PRE-01) | MIL-STD-461F p. 5.16 (RE101) Wyposazenie wojskowe Poziom zaburzen promieniowanych, pole magnetyczne w zakresie czestotliwosci: 100 Hz - 100 kHz NO-06-A500:2012, p.3.13 (procedura PRE-01) | MIL-STD-461F p. 5.16 (RE101)","categories":["other"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Military equipment Level of radiated disturbances, magnetic field in the frequency range: 100 Hz - 100 kHz NO-06-A500:2012, p.3.13 (procedura PRE-01) | MIL-STD-461F p. 5.16 (RE101)","search_zh":"军用装备 NO-06-A500:2012, p.3.13 (procedura PRE-01) | MIL-STD-461F p. 5.16 (RE101)","test_object_zh":"军用装备"},{"_id":"6a5dc9bcf1c10c8ce825e1ba","lab_id":"69ad52a3de79e566650fb384","country":"PL","accr_number":"AB 693","accr_body":"PCA","test_object":"Wyposażenie wojskowe","test_object_en":"Military equipment","methodology":"Poziom zaburzeń promieniowanych, pole elektryczne, wytwarzanych przez zespoły prądotwórcze w zakresie częstotliwości: 2 MHz - 18 GHz","methodology_en":"Level of radiated disturbances, electric field, produced by generating sets in the frequency range: 2 MHz - 18 GHz","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Poziom zaburzeń promieniowanych, pole elektryczne, wytwarzanych przez zespoły prądotwórcze w zakresie częstotliwości: 2 MHz - 18 GHz","reference":"NO-61-A208:2013 p. 2.1.15, 3.14 NO-06-A500:2012 p. 3.14 (procedura PRE-02)","norm_bases":["NO-61-A208:2013 p. 2.1.15, 3.14 NO-06-A500:2012 p. 3.14 (procedura PRE-02)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wyposażenie wojskowe Poziom zaburzeń promieniowanych, pole elektryczne, wytwarzanych przez zespoły prądotwórcze w zakresie częstotliwości: 2 MHz - 18 GHz NO-61-A208:2013 p. 2.1.15, 3.14 NO-06-A500:2012 p. 3.14 (procedura PRE-02) Wyposazenie wojskowe Poziom zaburzen promieniowanych, pole elektryczne, wytwarzanych przez zespoly pradotworcze w zakresie czestotliwosci: 2 MHz - 18 GHz NO-61-A208:2013 p. 2.1.15, 3.14 NO-06-A500:2012 p. 3.14 (procedura PRE-02)","categories":["other"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Military equipment Level of radiated disturbances, electric field, produced by generating sets in the frequency range: 2 MHz - 18 GHz NO-61-A208:2013 p. 2.1.15, 3.14 NO-06-A500:2012 p. 3.14 (procedura PRE-02)","search_zh":"军用装备 NO-61-A208:2013 p. 2.1.15, 3.14 NO-06-A500:2012 p. 3.14 (procedura PRE-02)","test_object_zh":"军用装备"}],"has_pdf":true}