🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL

PCA AB 681 • Kłodzko, Poland • 29 methods

Water & wastewaterMicrobiology

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 681 (Kłodzko, Poland). Its accreditation scope covers 29 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water (including swimming pool water), Drinking water, Water (including swimming pool water), Faeces. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 681
  • Methods in scope: 29
  • Types of test objects: 4
  • Techniques used: 11
  • City: Kłodzko, Poland
Accreditation number
AB 681
Accreditation body
PCA
Address
W KŁODZKU, ul. Stefana Okrzei 16, 57-300 Kłodzko
City
Kłodzko, Poland

What this laboratory tests (4)

Analytical techniques used (11)

Accreditation scope — test methods (29)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water pH
Range od ( 4,0 - 10,0 )
Potentiometric method PN-EN ISO 10523:2012
2 Water Electrical conductivity
Range (5 – 1500) μS/cm
Conductometric method PN-EN 27888:1999
3 Water Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012
4 Water Nitrite concentration
Range (0,003 – 0,821) mg/l Nitrite nitrogen concentration Range (0,001 – 0,250) mg/l
Spectrophotometric method PN-EN 26777:1999
5 Water Chloride concentration
Range (5,0-400,0 mg/l)
Titrimetric method PN-ISO 9297:1994
6 Water Total content of calcium and magnesium (total hardness)
Range (20 – 1000) mg/l
Titrimetric method PN-ISO 6059:1999
7 Water Total iron concentration
Range (10 – 4000) μg/l
Spectrophotometric method PN-ISO 6332:2001 p. 7.1 +PN-ISO 6332:2001/Ap1:2016-06
8 Water Ammonium nitrogen concentration
Range (0,016 – 0,78) mg/l Ammonium ion concentration Range (0,02 – 1,0) mg/l Ammonia concentration Range (0,02 – 1,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
9 Water Calcium concentration
Range (7,0 – 100) mg/l
Titrimetric method PN-ISO 6058:1999
10 Water Magnesium concentration calculated PN-C-04554-4:1999 Załącznik A
11 Water Manganese concentration
Range (30-4000) μg/l
Spectrophotometric method PN-92/C-04590-03
12 Water Sulfate concentration
Range (10 - 250) mg/l
Gravimetric method PN-ISO 9280:2002
13 Water (including swimming pool water) Permanganate index
Range (0,5 – 20,0) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
14 Water (including swimming pool water) Turbidity
Range (0,10 – 10,0) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09, pkt.5.3
15 Water (including swimming pool water) Nitrate concentration
Range (0,5 – 155) mg/l Nitrate nitrogen concentration Range (0,1 – 35) mg/l
Spectrophotometric method PN-82/C-04576.08
16 Water (including swimming pool water), Drinking water Count of microorganisms at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004
17 Water (including swimming pool water), Drinking water Count of microorganisms at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004
18 Water (including swimming pool water), Drinking water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
19 Water (including swimming pool water), Drinking water Coagulase-positive staphylococci count Membrane filtration method Metodyka PZH ZHK:2007
20 Water (including swimming pool water), Drinking water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
21 Water (including swimming pool water), Drinking water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
22 Water (including swimming pool water), Drinking water Count of Clostridium perfringens bacteria (including spores) Membrane filtration method PN-EN ISO 14189:2016-10
23 Water (including swimming pool water), Drinking water Legionella sp. count, Matrix A;, Procedure 5; BCYE medium, Procedure 7; GVPC medium, Matrix B;, Procedure 7; GVPC medium Membrane filtration method PN-EN ISO 11731:2017-08 + Ap1:2019-12
24 Water (including swimming pool water), Drinking water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
25 Water (including swimming pool water), Drinking water Coliform bacteria count MPN method PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)
26 Water (including swimming pool water), Drinking water Escherichia coli count MPN method PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)
27 Water (including swimming pool water), Drinking water Pseudomonas aeruginosa bacteria count MPN method Test Pseudalert/ Quanti-Tray (instrukcja producenta)
28 Faeces Presence of Salmonella sp. and Shigella sp. Culture method with biochemical and serological confirmation PB-01 wyd. 08 z dnia 01.12.2021 r.
29 Faeces Presence of Salmonella Enteritidis Culture method with biochemical and serological confirmation PB-01 wyd. 08 z dnia 01.12.2021 r.

Reference standards (25)

Metodyka PZH ZHK:2007
PB-01 wyd. 08 z dnia 01.12.2021 r.
PN-82/C-04576.08
PN-92/C-04590-03
PN-C-04554-4:1999 Załącznik A
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 + Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09, pkt.5.3
PN-EN ISO 7887:2012
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001 p. 7.1 +PN-ISO 6332:2001/Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
Test Pseudalert/ Quanti-Tray (instrukcja producenta)