🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL
Water & wastewaterMicrobiology
POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 681 (Kłodzko, Poland). Its accreditation scope covers 29 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water (including swimming pool water), Drinking water, Water (including swimming pool water), Faeces. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Titrimetric method.
At a glance
- Accreditation number: PCA AB 681
- Methods in scope: 29
- Types of test objects: 4
- Techniques used: 11
- City: Kłodzko, Poland
- Accreditation number
- AB 681
- Accreditation body
- PCA
- Address
- W KŁODZKU, ul. Stefana Okrzei 16, 57-300 Kłodzko
- City
- Kłodzko, Poland
What this laboratory tests (4)
- Water — 12 methods
- Water (including swimming pool water), Drinking water — 12 methods
- Water (including swimming pool water) — 3 methods
- Faeces — 2 methods
Analytical techniques used (11)
- Membrane filtration method — 7 methods
- Spectrophotometric method — 5 methods
- Titrimetric method — 4 methods
- MPN method — 3 methods
- Culture method with biochemical and serological confirmation — 2 methods
- Plate method (pour plate) — 2 methods
- Conductometric method — 1 method
- Gravimetric method — 1 method
- Nephelometric method — 1 method
- Potentiometric method — 1 method
- Visual method — 1 method
Accreditation scope — test methods (29)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water | pH Range od ( 4,0 - 10,0 ) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 2 | Water | Electrical conductivity Range (5 – 1500) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 3 | Water | Colour Range (5 – 70) mg/l Pt |
Visual method | PN-EN ISO 7887:2012 | |
| 4 | Water | Nitrite concentration Range (0,003 – 0,821) mg/l Nitrite nitrogen concentration Range (0,001 – 0,250) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 5 | Water | Chloride concentration Range (5,0-400,0 mg/l) |
Titrimetric method | PN-ISO 9297:1994 | |
| 6 | Water | Total content of calcium and magnesium (total hardness) Range (20 – 1000) mg/l |
Titrimetric method | PN-ISO 6059:1999 | |
| 7 | Water | Total iron concentration Range (10 – 4000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001 p. 7.1 +PN-ISO 6332:2001/Ap1:2016-06 | |
| 8 | Water | Ammonium nitrogen concentration Range (0,016 – 0,78) mg/l Ammonium ion concentration Range (0,02 – 1,0) mg/l Ammonia concentration Range (0,02 – 1,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 9 | Water | Calcium concentration Range (7,0 – 100) mg/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 10 | Water | Magnesium concentration calculated | PN-C-04554-4:1999 Załącznik A | ||
| 11 | Water | Manganese concentration Range (30-4000) μg/l |
Spectrophotometric method | PN-92/C-04590-03 | |
| 12 | Water | Sulfate concentration Range (10 - 250) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 13 | Water (including swimming pool water) | Permanganate index Range (0,5 – 20,0) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 14 | Water (including swimming pool water) | Turbidity Range (0,10 – 10,0) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09, pkt.5.3 | |
| 15 | Water (including swimming pool water) | Nitrate concentration Range (0,5 – 155) mg/l Nitrate nitrogen concentration Range (0,1 – 35) mg/l |
Spectrophotometric method | PN-82/C-04576.08 | |
| 16 | Water (including swimming pool water), Drinking water | Count of microorganisms at 36 oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 17 | Water (including swimming pool water), Drinking water | Count of microorganisms at 22 oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 18 | Water (including swimming pool water), Drinking water | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 19 | Water (including swimming pool water), Drinking water | Coagulase-positive staphylococci count | Membrane filtration method | Metodyka PZH ZHK:2007 | |
| 20 | Water (including swimming pool water), Drinking water | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 21 | Water (including swimming pool water), Drinking water | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 22 | Water (including swimming pool water), Drinking water | Count of Clostridium perfringens bacteria (including spores) | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 23 | Water (including swimming pool water), Drinking water | Legionella sp. count, Matrix A;, Procedure 5; BCYE medium, Procedure 7; GVPC medium, Matrix B;, Procedure 7; GVPC medium | Membrane filtration method | PN-EN ISO 11731:2017-08 + Ap1:2019-12 | |
| 24 | Water (including swimming pool water), Drinking water | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 25 | Water (including swimming pool water), Drinking water | Coliform bacteria count | MPN method | PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray) | |
| 26 | Water (including swimming pool water), Drinking water | Escherichia coli count | MPN method | PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray) | |
| 27 | Water (including swimming pool water), Drinking water | Pseudomonas aeruginosa bacteria count | MPN method | Test Pseudalert/ Quanti-Tray (instrukcja producenta) | |
| 28 | Faeces | Presence of Salmonella sp. and Shigella sp. | Culture method with biochemical and serological confirmation | PB-01 wyd. 08 z dnia 01.12.2021 r. | |
| 29 | Faeces | Presence of Salmonella Enteritidis | Culture method with biochemical and serological confirmation | PB-01 wyd. 08 z dnia 01.12.2021 r. | |
Reference standards (25)
Metodyka PZH ZHK:2007
PB-01 wyd. 08 z dnia 01.12.2021 r.
PN-82/C-04576.08
PN-92/C-04590-03
PN-C-04554-4:1999 Załącznik A
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 + Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09, pkt.5.3
PN-EN ISO 7887:2012
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001 p. 7.1 +PN-ISO 6332:2001/Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
Test Pseudalert/ Quanti-Tray (instrukcja producenta)