{"lab":{"_id":"69ad52a3de79e566650fb378","accr_number":"AB 681","country":"PL","accr_body":"PCA","address":"W KŁODZKU, ul. Stefana Okrzei 16, 57-300 Kłodzko","categories":["water","microbiology"],"city":"Kłodzko","imported_at":"2026-03-08T10:42:43.265Z","methods_count":29,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_681.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w kłodzku, ul. stefana okrzei 16, 57-300 kłodzko other water pharma electronics automotive microbiology","status":"active","updated_at":"2026-03-08T14:51:34.953Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:34.953Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20681,podmiot.html","fields_of_testing":[{"codes":"C/28, C/29","pl":"Badania chemiczne wody, wody przeznaczonej do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"K/3, K/28, K/29","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, wody, wody przeznaczonej do spożycia przez ludzi","en":"Microbiological tests of biological items and materials for testing, water, drinking water"},{"codes":"N/28, N/29","pl":"Badania właściwości fizycznych wody, wody przeznaczonej do spożycia przez ludzi","en":"Test of physical properties of water, drinking water"}],"issue":{"no":"18","date":"22.01.2026"},"parse_date":"2026-07-20T07:09:47.459Z","parse_source":"script-pdfplumber","map_coord":[50.433338,16.650697],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":27,"microbiology":9},"category_scores":{"water":20.25,"microbiology":2.25},"has_zh":true},"methods":[{"_id":"6a5dc9bbf1c10c8ce825df6c","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"od ( 4,0 - 10,0 )"}],"parameters_en":[{"name":"Range","range":"od ( 4,0 - 10,0 )"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres od ( 4,0 - 10,0 )\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda pH\nZakres od ( 4,0 - 10,0 )\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda pH\nZakres od ( 4,0 - 10,0 )\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"od ( 4,0 - 10,0 )"}],"search_zh":"水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df6d","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(5 – 1500) μS/cm"}],"parameters_en":[{"name":"Range","range":"(5 – 1500) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 – 1500) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (5 – 1500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (5 – 1500) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 – 1500) μS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df6e","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 – 70) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 – 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012","norm_bases":["PN-EN ISO 7887:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 Woda Barwa\nZakres (5 – 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Colour Visual method Range PN-EN ISO 7887:2012","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 70) mg/l Pt"}],"search_zh":"水 色度 目视法 范围 PN-EN ISO 7887:2012","technique_zh":"目视法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df6f","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,003 – 0,821) mg/l"},{"name":"Stężenie azotu azotynowego"},{"name":"Zakres","range":"(0,001 – 0,250) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,003 – 0,821) mg/l"},{"name":"Nitrite nitrogen concentration"},{"name":"Range","range":"(0,001 – 0,250) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres:\nZakres (0,003 – 0,821) mg/l\nStężenie azotu azotynowego\nZakres (0,001 – 0,250) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotynów\nZakres:\nZakres (0,003 – 0,821) mg/l\nStężenie azotu azotynowego\nZakres (0,001 – 0,250) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotynow\nZakres:\nZakres (0,003 – 0,821) mg/l\nStezenie azotu azotynowego\nZakres (0,001 – 0,250) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Nitrite concentration Spectrophotometric method Range Nitrite nitrogen concentration Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,003 – 0,821) mg/l"},{"name":"亚硝态氮浓度"},{"name":"范围","range":"(0,001 – 0,250) mg/l"}],"search_zh":"水 亚硝酸盐浓度 分光光度法 范围 亚硝态氮浓度 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df70","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0-400,0 mg/l)"}],"parameters_en":[{"name":"Range","range":"(5,0-400,0 mg/l)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0-400,0 mg/l)\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chlorków\nZakres (5,0-400,0 mg/l)\nMetoda miareczkowa PN-ISO 9297:1994 Woda Stezenie chlorkow\nZakres (5,0-400,0 mg/l)\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0-400,0 mg/l)"}],"search_zh":"水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df71","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(20 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(20 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (20 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (20 – 1000) mg/l\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (20 – 1000) mg/l\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(20 – 1000) mg/l"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df72","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(10 – 4000) μg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 4000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (10 – 4000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 p. 7.1 +PN-ISO 6332:2001/Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 p. 7.1 +PN-ISO 6332:2001/Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie żelaza ogólnego\nZakres (10 – 4000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 p. 7.1 +PN-ISO 6332:2001/Ap1:2016-06 Woda Stezenie zelaza ogolnego\nZakres (10 – 4000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001 p. 7.1 +PN-ISO 6332:2001/Ap1:2016-06","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001 p. 7.1 +PN-ISO 6332:2001/Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(10 – 4000) μg/l"}],"search_zh":"水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001 p. 7.1 +PN-ISO 6332:2001/Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df73","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,016 – 0,78) mg/l"},{"name":"Stężenie jonu amonowego"},{"name":"Zakres","range":"(0,02 – 1,0) mg/l"},{"name":"Stężenie amoniaku"},{"name":"Zakres","range":"(0,02 – 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,016 – 0,78) mg/l"},{"name":"Ammonium ion concentration"},{"name":"Range","range":"(0,02 – 1,0) mg/l"},{"name":"Ammonia concentration"},{"name":"Range","range":"(0,02 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres:\nZakres (0,016 – 0,78) mg/l\nStężenie jonu amonowego\nZakres (0,02 – 1,0) mg/l\nStężenie amoniaku\nZakres (0,02 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie azotu amonowego\nZakres:\nZakres (0,016 – 0,78) mg/l\nStężenie jonu amonowego\nZakres (0,02 – 1,0) mg/l\nStężenie amoniaku\nZakres (0,02 – 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Stezenie azotu amonowego\nZakres:\nZakres (0,016 – 0,78) mg/l\nStezenie jonu amonowego\nZakres (0,02 – 1,0) mg/l\nStezenie amoniaku\nZakres (0,02 – 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Ammonium nitrogen concentration Spectrophotometric method Range Ammonium ion concentration Range Ammonia concentration Range PN-ISO 7150-1:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,016 – 0,78) mg/l"},{"name":"铵离子浓度"},{"name":"范围","range":"(0,02 – 1,0) mg/l"},{"name":"氨浓度"},{"name":"范围","range":"(0,02 – 1,0) mg/l"}],"search_zh":"水 氨氮浓度 分光光度法 范围 铵离子浓度 范围 氨浓度 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df74","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(7,0 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(7,0 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (7,0 – 100) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie wapnia\nZakres (7,0 – 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda Stezenie wapnia\nZakres (7,0 – 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Calcium concentration Titrimetric method Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(7,0 – 100) mg/l"}],"search_zh":"水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"钙浓度"},{"_id":"6a5dc9bbf1c10c8ce825df75","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie magnezu z obliczeń","methodology_en":"Magnesium concentration calculated","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu z obliczeń","reference":"PN-C-04554-4:1999 Załącznik A","norm_bases":["PN-C-04554-4:1999 Załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie magnezu z obliczeń PN-C-04554-4:1999 Załącznik A Woda Stezenie magnezu z obliczen PN-C-04554-4:1999 Zalacznik A","categories":["water"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Magnesium concentration calculated PN-C-04554-4:1999 Załącznik A","search_zh":"水 PN-C-04554-4:1999 Załącznik A","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df76","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(30-4000) μg/l"}],"parameters_en":[{"name":"Range","range":"(30-4000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (30-4000) μg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590-03","norm_bases":["PN-92/C-04590-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie manganu\nZakres (30-4000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590-03 Woda Stezenie manganu\nZakres (30-4000) μg/l\nMetoda spektrofotometryczna PN-92/C-04590-03","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Manganese concentration Spectrophotometric method Range PN-92/C-04590-03","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(30-4000) μg/l"}],"search_zh":"水 锰浓度 分光光度法 范围 PN-92/C-04590-03","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df77","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(10 - 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 - 250) mg/l"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (10 - 250) mg/l\nMetoda grawimetryczna","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie siarczanów\nZakres (10 - 250) mg/l\nMetoda grawimetryczna PN-ISO 9280:2002 Woda Stezenie siarczanow\nZakres (10 - 250) mg/l\nMetoda grawimetryczna PN-ISO 9280:2002","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 - 250) mg/l"}],"search_zh":"水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825df78","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,5 – 20,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 20,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 – 20,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Indeks nadmanganianowy\nZakres (0,5 – 20,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalniach) Indeks nadmanganianowy\nZakres (0,5 – 20,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 – 20,0) mg/l O2"}],"search_zh":"水（含游泳池水） 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9bbf1c10c8ce825df79","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 – 10,0) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 – 10,0) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 – 10,0) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09, pkt.5.3","norm_bases":["PN-EN ISO 7027-1:2016-09, pkt.5.3"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Mętność\nZakres (0,10 – 10,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09, pkt.5.3 Woda (w tym woda na plywalniach) Metnosc\nZakres (0,10 – 10,0) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09, pkt.5.3","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09, pkt.5.3","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 10,0) NTU"}],"search_zh":"水（含游泳池水） 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09, pkt.5.3","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9bbf1c10c8ce825df7a","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","test_object_en":"Water (including swimming pool water)","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,5 – 155) mg/l"},{"name":"Stężenie azotu azotanowego"},{"name":"Zakres","range":"(0,1 – 35) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,5 – 155) mg/l"},{"name":"Nitrate nitrogen concentration"},{"name":"Range","range":"(0,1 – 35) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres:\nZakres (0,5 – 155) mg/l\nStężenie azotu azotanowego\nZakres (0,1 – 35) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach) Stężenie azotanów\nZakres:\nZakres (0,5 – 155) mg/l\nStężenie azotu azotanowego\nZakres (0,1 – 35) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda (w tym woda na plywalniach) Stezenie azotanow\nZakres:\nZakres (0,5 – 155) mg/l\nStezenie azotu azotanowego\nZakres (0,1 – 35) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water) Nitrate concentration Spectrophotometric method Range Nitrate nitrogen concentration Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,5 – 155) mg/l"},{"name":"硝态氮浓度"},{"name":"范围","range":"(0,1 – 35) mg/l"}],"search_zh":"水（含游泳池水） 硝酸盐浓度 分光光度法 范围 硝态氮浓度 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a5dc9bbf1c10c8ce825df7b","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia","test_object_en":"Water (including swimming pool water), Drinking water","methodology":"Liczba mikroorganizmów w temp. 36 oC","methodology_en":"Count of microorganisms at 36 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Liczba mikroorganizmów w temp. 36 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia Liczba mikroorganizmów w temp. 36 oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalniach), Woda do spozycia Liczba mikroorganizmow w temp. 36 oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Drinking water Count of microorganisms at 36 oC Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水（含游泳池水）、饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df7c","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia","test_object_en":"Water (including swimming pool water), Drinking water","methodology":"Liczba mikroorganizmów w temp. 22 oC","methodology_en":"Count of microorganisms at 22 oC","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Liczba mikroorganizmów w temp. 22 oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia Liczba mikroorganizmów w temp. 22 oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalniach), Woda do spozycia Liczba mikroorganizmow w temp. 22 oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Drinking water Count of microorganisms at 22 oC Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水（含游泳池水）、饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）、饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df7d","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia","test_object_en":"Water (including swimming pool water), Drinking water","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym woda na plywalniach), Woda do spozycia Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Drinking water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水）、饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df7e","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia","test_object_en":"Water (including swimming pool water), Drinking water","methodology":"Liczba gronkowców koagulazododatnich","methodology_en":"Coagulase-positive staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"Metodyka PZH ZHK:2007","norm_bases":["Metodyka PZH ZHK:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej Metodyka PZH ZHK:2007 Woda (w tym woda na plywalniach), Woda do spozycia Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej Metodyka PZH ZHK:2007","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Drinking water Coagulase-positive staphylococci count Membrane filtration method Metodyka PZH ZHK:2007","search_zh":"水（含游泳池水）、饮用水 凝固酶阳性葡萄球菌计数 膜过滤法 Metodyka PZH ZHK:2007","technique_zh":"膜过滤法","methodology_zh":"凝固酶阳性葡萄球菌计数","test_object_zh":"水（含游泳池水）、饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df7f","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia","test_object_en":"Water (including swimming pool water), Drinking water","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym woda na plywalniach), Woda do spozycia Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Drinking water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水（含游泳池水）、饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df80","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia","test_object_en":"Water (including swimming pool water), Drinking water","methodology":"Liczba bakterii Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym woda na plywalniach), Woda do spozycia Liczba bakterii Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["microbiology","water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Drinking water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水（含游泳池水）、饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df81","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia","test_object_en":"Water (including swimming pool water), Drinking water","methodology":"Liczba bakterii Clostridium perfringens (łącznie ze sporami)","methodology_en":"Count of Clostridium perfringens bacteria (including spores)","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia Liczba bakterii Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda (w tym woda na plywalniach), Woda do spozycia Liczba bakterii Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water","microbiology"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Drinking water Count of Clostridium perfringens bacteria (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水（含游泳池水）、饮用水 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df82","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia","test_object_en":"Water (including swimming pool water), Drinking water","methodology":"Liczba bakterii Legionella sp., Matryca A;, Procedura 5; Pożywka BCYE, Procedura 7; Pożywka GVPC, Matryca B;, Procedura 7; Pożywka GVPC","methodology_en":"Legionella sp. count, Matrix A;, Procedure 5; BCYE medium, Procedure 7; GVPC medium, Matrix B;, Procedure 7; GVPC medium","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii Legionella sp., Matryca A;, Procedura 5; Pożywka BCYE, Procedura 7; Pożywka GVPC, Matryca B;, Procedura 7; Pożywka GVPC\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 + Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 + Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia Liczba bakterii Legionella sp., Matryca A;, Procedura 5; Pożywka BCYE, Procedura 7; Pożywka GVPC, Matryca B;, Procedura 7; Pożywka GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12 Woda (w tym woda na plywalniach), Woda do spozycia Liczba bakterii Legionella sp., Matryca A;, Procedura 5; Pozywka BCYE, Procedura 7; Pozywka GVPC, Matryca B;, Procedura 7; Pozywka GVPC\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 + Ap1:2019-12","categories":["microbiology","water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Drinking water Legionella sp. count, Matrix A;, Procedure 5; BCYE medium, Procedure 7; GVPC medium, Matrix B;, Procedure 7; GVPC medium Membrane filtration method PN-EN ISO 11731:2017-08 + Ap1:2019-12","search_zh":"水（含游泳池水）、饮用水 膜过滤法 PN-EN ISO 11731:2017-08 + Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df83","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia","test_object_en":"Water (including swimming pool water), Drinking water","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda (w tym woda na plywalniach), Woda do spozycia Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Drinking water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"水（含游泳池水）、饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df84","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia","test_object_en":"Water (including swimming pool water), Drinking water","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)","norm_bases":["PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia Liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray) Woda (w tym woda na plywalniach), Woda do spozycia Liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)","categories":["water","microbiology"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Drinking water Coliform bacteria count MPN method PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)","methodology_zh":"大肠菌群计数","search_zh":"水（含游泳池水）、饮用水 大肠菌群计数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)","technique_zh":"最可能数法（MPN）","test_object_zh":"水（含游泳池水）、饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df85","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia","test_object_en":"Water (including swimming pool water), Drinking water","methodology":"Liczba bakterii Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Liczba bakterii Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)","norm_bases":["PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia Liczba bakterii Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray) Woda (w tym woda na plywalniach), Woda do spozycia Liczba bakterii Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)","categories":["microbiology","water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Drinking water Escherichia coli count MPN method PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水（含游泳池水）、饮用水 大肠埃希氏菌（Escherichia coli）计数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06 (test Colilert-18/Quanti-Tray)","technique_zh":"最可能数法（MPN）","test_object_zh":"水（含游泳池水）、饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df86","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), Woda do spożycia","test_object_en":"Water (including swimming pool water), Drinking water","methodology":"Liczba bakterii Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Liczba bakterii Pseudomonas aeruginosa\nMetoda NPL","reference":"Test Pseudalert/ Quanti-Tray (instrukcja producenta)","norm_bases":["Test Pseudalert/ Quanti-Tray (instrukcja producenta)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), Woda do spożycia Liczba bakterii Pseudomonas aeruginosa\nMetoda NPL Test Pseudalert/ Quanti-Tray (instrukcja producenta) Woda (w tym woda na plywalniach), Woda do spozycia Liczba bakterii Pseudomonas aeruginosa\nMetoda NPL Test Pseudalert/ Quanti-Tray (instrukcja producenta)","categories":["water","microbiology"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), Drinking water Pseudomonas aeruginosa bacteria count MPN method Test Pseudalert/ Quanti-Tray (instrukcja producenta)","search_zh":"水（含游泳池水）、饮用水 铜绿假单胞菌数 最可能数法（MPN） Test Pseudalert/ Quanti-Tray (instrukcja producenta)","technique_zh":"最可能数法（MPN）","methodology_zh":"铜绿假单胞菌数","test_object_zh":"水（含游泳池水）、饮用水"},{"_id":"6a5dc9bbf1c10c8ce825df87","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Kał","test_object_en":"Faeces","methodology":"Obecność pałeczek Salmonella sp. i Shigella sp.","methodology_en":"Presence of Salmonella sp. and Shigella sp.","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność pałeczek Salmonella sp. i Shigella sp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-01 wyd. 08 z dnia 01.12.2021 r.","norm_bases":["PB-01 wyd. 08 z dnia 01.12.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kał Obecność pałeczek Salmonella sp. i Shigella sp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-01 wyd. 08 z dnia 01.12.2021 r. Kal Obecnosc paleczek Salmonella sp. i Shigella sp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-01 wyd. 08 z dnia 01.12.2021 r.","categories":["microbiology"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Faeces Presence of Salmonella sp. and Shigella sp. Culture method with biochemical and serological confirmation PB-01 wyd. 08 z dnia 01.12.2021 r.","search_zh":"粪便 培养法结合生化与血清学确认 PB-01 wyd. 08 z dnia 01.12.2021 r.","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"粪便"},{"_id":"6a5dc9bbf1c10c8ce825df88","lab_id":"69ad52a3de79e566650fb378","country":"PL","accr_number":"AB 681","accr_body":"PCA","test_object":"Kał","test_object_en":"Faeces","methodology":"Obecność Salmonella Enteritidis","methodology_en":"Presence of Salmonella Enteritidis","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność Salmonella Enteritidis\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-01 wyd. 08 z dnia 01.12.2021 r.","norm_bases":["PB-01 wyd. 08 z dnia 01.12.2021 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Kał Obecność Salmonella Enteritidis\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-01 wyd. 08 z dnia 01.12.2021 r. Kal Obecnosc Salmonella Enteritidis\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-01 wyd. 08 z dnia 01.12.2021 r.","categories":["microbiology"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Faeces Presence of Salmonella Enteritidis Culture method with biochemical and serological confirmation PB-01 wyd. 08 z dnia 01.12.2021 r.","search_zh":"粪便 肠炎沙门氏菌的检出 培养法结合生化与血清学确认 PB-01 wyd. 08 z dnia 01.12.2021 r.","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"粪便","methodology_zh":"肠炎沙门氏菌的检出"}],"has_pdf":true}