🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL

PCA AB 671 • Włoszczowa, Poland • 40 methods

Water & wastewaterEnvironmentMicrobiology

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 671 (Włoszczowa, Poland). Its accreditation scope covers 40 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Water, Water intended for human consumption, Swimming pool water, Workplace environment − air, Workplace environment − indoor electric lighting. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Direct measurement method.

At a glance

  • Accreditation number: PCA AB 671
  • Methods in scope: 40
  • Types of test objects: 9
  • Techniques used: 15
  • City: Włoszczowa, Poland
Accreditation number
AB 671
Accreditation body
PCA
Address
WE WŁOSZCZOWIE, ul. Sobieskiego 38, 29-100 Włoszczowa
City
Włoszczowa, Poland

What this laboratory tests (9)

Analytical techniques used (15)

Laboratory sections (3)

Laboratory locations

Accreditation scope — test methods (40)

No. Test object Methodology / Parameters Technique Reference document
Workplace Environment Testing and Measurement Laboratory
1 Workplace environment − air Sampling for the assessment of occupational exposure to:
industrial dusts inhalable fraction respirable fraction inorganic substances respirable fraction
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
2 Workplace environment − air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
3 Workplace environment − air Concentration of harmful dust agents – inhalable fraction
Range (0,10 – 20,48) mg/m3
Gravimetric method PN-Z-04507:2022-05+Ap1:2022-08
4 Workplace environment − air Concentration of harmful dust agents – respirable fraction
Range (0,12 – 13,50) mg/m3
Gravimetric method PN-Z-04508:2022-05+Ap1:2022-08
5 Workplace environment − air Carbon monoxide concentration
Range (2,34 – 200) mg/m3
Electrochemical method PB/PBiPŚP/01 wydanie 3 z dnia 29.12.2023 r.
6 Workplace environment − noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (40 – 135) dB C-weighted peak sound pressure level Range (40 – 138) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – pkt 10 i strategię nr 3 – pkt 11
7 Workplace environment − noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – pkt 10 i strategię nr 3 – pkt 11
8 Workplace environment − noise (selection of hearing protectors) Equivalent sound pressure level in octave frequency bands
Range (63 – 8 000) Hz Range (40 – 135) dB A-weighted equivalent sound pressure level C-weighted equivalent sound pressure level Range (40 – 135) dB
Direct measurement method PN-EN ISO 4869-2:2002 | PN-EN 458:2016 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – pkt 10 i strategię nr 3 – pkt 11
9 Workplace environment − noise (selection of hearing protectors) Effective A-weighted sound level under hearing protectors (calculated) PN-EN ISO 4869-2:2002 | PN-EN 458:2016 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – pkt 10 i strategię nr 3 – pkt 11
10 Workplace environment − indoor electric lighting Illuminance
Range (20 – 1000) lx
Direct measurement method PN-83/E-04040.03
11 Workplace environment − indoor electric lighting Illuminance uniformity (calculated) PN-83/E-04040.03
Microbiology, Parasitology and Culture Media Laboratory
12 Faeces / rectal swab Presence of Salmonella and Shigella rods Culture method with biochemical and serological confirmation PB/PMPiP/01 wydanie 2 z dnia 06.09.2007 r.
13 Biological indicator for monitoring the effectiveness of the sterilisation process Presence of indicator microorganisms – Geobacillus stearothermophilus Culture method PB/PMPiP/02 wydanie 2 z dnia 31.08.2016 r.
Environmental Hygiene Testing Laboratory
14 Water, Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
15 Water, Water intended for human consumption Turbidity
Range (0,06 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
16 Water, Water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 +Ap1:2015
17 Water, Water intended for human consumption Electrical conductivity
Range (74 – 5000) μS/cm
Conductometric method PN-EN 27888:1999
18 Water, Water intended for human consumption Nitrate concentration
Range (0,50 – 100) mg/l
Spectrophotometric method PN-82/C-04576.08
19 Water, Water intended for human consumption Nitrite concentration
Range (0,010 – 0,80) mg/l
Spectrophotometric method PN-EN 26777:1999
20 Water, Water intended for human consumption Ammonium ion concentration
Range (0,15 – 2,5) mg/l
Spectrophotometric method PN-C-04576-4:1994
21 Water, Water intended for human consumption Total iron concentration
Range (30 – 5000) μg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016
22 Water, Water intended for human consumption Manganese concentration
Range (30 – 1000) μg/l
Spectrophotometric method PN-92/C-04590/03
23 Swimming pool water, Water intended for human consumption Permanganate index (Oxidisability)
Range (0,50 – 10) mg/l
Titrimetric method PN-EN ISO 8467:2001
24 Swimming pool water Turbidity
Range (0,06 – 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
25 Swimming pool water Nitrate concentration
Range (0,50 – 100) mg/l
Spectrophotometric method PN-82/C-04576.08
26 Swimming pool water Total chlorine concentration
Range (0,1 – 3,0) mg/l
Colorimetric method PB/PBHŚ/01 wydanie 2 z dnia 07.12.2022 r. | na podstawie testów: HI 93711-01, HI 93701-01
27 Swimming pool water Free chlorine concentration
Range (0,1 – 2,5) mg/l
Colorimetric method PB/PBHŚ/01 wydanie 2 z dnia 07.12.2022 r. | na podstawie testów: HI 93711-01, HI 93701-01
28 Swimming pool water Combined chlorine concentration (calculated) PB/PBHŚ/01 wydanie 2 z dnia 07.12.2022 r. | na podstawie testów: HI 93711-01, HI 93701-01
29 Swimming pool water Redox potential (oxidation-reduction) at an Ag/AgCl 3,5 m KCl electrode
Range (200 – 850) mV
Potentiometric method PB/PBHŚ/02 wydanie 2 z dnia 07.12.2022 r.
30 Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
31 Water, Water intended for human consumption Total viable count at 22°C Plate method, pour plate PN-EN ISO 6222:2004
32 Water, Water intended for human consumption Total viable count at 36°C Plate method, pour plate PN-EN ISO 6222:2004
33 Water, Water intended for human consumption Legionella sp. count
Range od 1 jtk/100 ml Range od 1 jtk/1000 ml Matrix A, procedure: 5 (medium BCYE), 7 (medium GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
34 Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
35 Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
36 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PB/PBHŚ/06 wydanie 2 z dnia 30.08.2016 r.
37 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
38 Swimming pool water Total viable count at 36°C Plate method, pour plate PN-EN ISO 6222:2004
39 Swimming pool water Legionella sp. count
Range od 1 jtk/100 ml Matrix A, procedure: 5 (medium BCYE), 7 (medium GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
40 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04

Reference standards (30)

PB/PBHŚ/01 wydanie 2 z dnia 07.12.2022 r.
PB/PBHŚ/02 wydanie 2 z dnia 07.12.2022 r.
PB/PBHŚ/06 wydanie 2 z dnia 30.08.2016 r.
PB/PBiPŚP/01 wydanie 3 z dnia 29.12.2023 r.
PB/PMPiP/01 wydanie 2 z dnia 06.09.2007 r.
PB/PMPiP/02 wydanie 2 z dnia 31.08.2016 r.
PN-82/C-04576.08
PN-83/E-04040.03
PN-92/C-04590/03
PN-C-04576-4:1994
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 458:2016
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 4869-2:2002
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 +Ap1:2015
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię nr 2 – pkt 10 i strategię nr 3 – pkt 11
PN-ISO 6332:2001+Ap1:2016
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04507:2022-05+Ap1:2022-08
PN-Z-04508:2022-05+Ap1:2022-08
na podstawie testów: HI 93711-01, HI 93701-01