🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL

PCA AB 668 • Zgorzelec, Poland • 35 methods

Water & wastewaterMicrobiology

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 668 (Zgorzelec, Poland). Its accreditation scope covers 35 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Swimming pool water, Faeces, Biological indicator for sterilization process efficacy control - a…. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Plate method (pour plate).

At a glance

  • Accreditation number: PCA AB 668
  • Methods in scope: 35
  • Types of test objects: 5
  • Techniques used: 11
  • City: Zgorzelec, Poland
Accreditation number
AB 668
Accreditation body
PCA
Address
W ZGORZELCU, ul. Warszawska 11, 59-900 Zgorzelec
City
Zgorzelec, Poland

What this laboratory tests (5)

Analytical techniques used (11)

Accreditation scope — test methods (35)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, Water intended for human consumption Total concentration of calcium and magnesium (total hardness)
Range (6– 350) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
2 Water, Water intended for human consumption Calcium concentration
Range (3– 100) mg/l
Titrimetric method PN-ISO 6058:1999
3 Water, Water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999, Załącznik A
4 Water, Water intended for human consumption Electrical conductivity
Range (300– 1410) μS/cm
Conductometric method PN-EN 27888: 1999
5 Water, Water intended for human consumption Total manganese concentration
Range (0,030 – 0,500) mg/l
Spectrophotometric method PN-92/C-04590.03
6 Water, Water intended for human consumption Nitrate concentration
Range (0,50 – 80,0) mg/l
Spectrophotometric method PN-82/C-04576.08
7 Water, Water intended for human consumption Nitrite concentration
Range (0,020 – 1,600) mg/l
Spectrophotometric method PN-EN 26777:1999
8 Water, Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523: 2012
9 Water, Water intended for human consumption Chloride concentration
Range (2,00– 150) mg/I
Titrimetric method PN-ISO 9297:1994
10 Water, Water intended for human consumption Total iron concentration
Range (0,030 – 0,50) mg/I
Spectrophotometric method PN-ISO 6332:2001 + Ap1:2016-06
11 Water, Water intended for human consumption Turbidity
Range (0,13– 80) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09 z wył. pkt 5.4
12 Water, Water intended for human consumption Ammonium ion concentration
Range (0,037-1,30) mg/l Ammonia concentration Range (0,035 – 1,20) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
13 Water intended for human consumption Colour
Range (5 – 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 p.7
14 Swimming pool water Turbidity
Range (0,13– 80) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09 z wył. pkt 5.4
15 Swimming pool water Total iron concentration
Range (0,030 – 0,50) mg/I
Spectrophotometric method PN-ISO 6332:2001 + Ap1:2016-06
16 Swimming pool water Nitrate concentration
Range (0,50 – 80,0) mg/l
Spectrophotometric method PN-82/C-04576.08
17 Swimming pool water pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523: 2012
18 Water, Water intended for human consumption Total count of microorganisms on nutrient agar at a temperature of 220C Plate method (pour plate) PN-EN ISO 6222:2004
19 Water, Water intended for human consumption Total count of microorganisms on nutrient agar at 360C Plate method (pour plate) PN-EN ISO 6222:2004
20 Water, Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
21 Water, Water intended for human consumption Clostridium perfringens count Membrane filtration method PN-EN ISO 14189:2016-10
22 Water, Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04
23 Water, Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04
24 Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
25 Water, Water intended for human consumption Legionella sp. count
Matrix A Procedure 5 (medium A), Procedure 7 (medium C) GVPC
Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
26 Water, Water intended for human consumption Legionella sp. count
Matrix A Procedure 1 (medium A, B)
Surface method PN-EN ISO 11731:2017-08 +Ap1:2019-12
27 Swimming pool water Total count of microorganisms on nutrient agar at 360C Plate method (pour plate) PN-EN ISO 6222:2004
28 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
29 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
30 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000 Załącznik A
31 Swimming pool water Legionella sp. count
Matrix A Procedure 5 (medium A), Procedure 7 (medium C) GVPC
Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
32 Swimming pool water Legionella sp. count
Matrix A Procedure 1 (medium A, B)
Surface method PN-EN ISO 11731:2017-08 +Ap1:2019-12
33 Faeces Presence of Salmonella sp. and, Shigella sp. Culture method with biochemical and serological confirmation PB-07.00.00 edycja 6 z dnia 28.10.2025 r.
34 Faeces Presence of Salmonella rods, Enteritidis Culture method with biochemical and serological confirmation PB-07.00.00 edycja 6 z dnia 28.10.2025 r.
35 Biological indicator for sterilization process efficacy control - ampoule test - paper strip test Presence of the microorganism:
Geobacillus stearothermophilus Bacillus subtilis
Culture method PB-09.00.00 edycja 5 z dnia 30.12.2019 r.

Reference standards (23)

PB-07.00.00 edycja 6 z dnia 28.10.2025 r.
PB-09.00.00 edycja 5 z dnia 30.12.2019 r.
PN-82/C-04576.08
PN-92/C-04590.03
PN-C-04554-4:1999, Załącznik A
PN-EN 26777:1999
PN-EN 27888: 1999
PN-EN ISO 10523: 2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09 z wył. pkt 5.4
PN-EN ISO 7887:2012 p.7
PN-EN ISO 7899-2:2004
PN-EN ISO 9308-1:2014-12 + A1:2017-04
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001 + Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994
PN-Z-11001-3:2000 Załącznik A