🇵🇱 „EKO-SERWIS” s.c. PL
Water & wastewaterEnvironmentMicrobiologyMaterials & polymers
„EKO-SERWIS” s.c. is a laboratory accredited by PCA under number AB 667 (Łódź, Poland). Its accreditation scope covers 132 test methods in the following areas: Water & wastewater, Environment, Microbiology, Materials & polymers. Test objects include: Water, wastewater, Water, Swimming pool water, Waste o) code: 19 08 05. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.
At a glance
- Accreditation number: PCA AB 667
- Methods in scope: 132
- Types of test objects: 20
- Techniques used: 26
- City: Łódź, Poland
- Accreditation number
- AB 667
- Accreditation body
- PCA
- Address
- Dorota Markowska, Maciej Markowski, ul. Wierzbowa 48, 90-133 Łódź
- City
- Łódź, Poland
What this laboratory tests (20)
- Water, wastewater — 32 methods
- Water — 19 methods
- Swimming pool water — 15 methods
- Waste o) code: 19 08 05 — 12 methods
- Water, water intended for human consumption — 12 methods
- Sewage sludge — 8 methods
- Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 — 8 methods
- Water (including swimming pool water), water intended for human consumption — 5 methods
- Soil — 4 methods
- Wastewater — 4 methods
- Bathing water — 2 methods
- Rainwater and snowmelt water — 2 methods
- Sewage sludge, waste o) code: 19 08 05 — 2 methods
- Groundwater — 1 method
- Sewage sludge, waste o) code: 19 08 05 02 02 04 — 1 method
- and 5 more
Analytical techniques used (26)
- Spectrophotometric method — 25 methods
- Titrimetric method — 17 methods
- Membrane filtration method — 13 methods
- Gravimetric method — 12 methods
- Potentiometric method — 6 methods
- MPN method — 4 methods
- Gas chromatography with electron capture detection (GC-ECD) — 3 methods
- Inductively coupled plasma optical emission spectrometry (ICP–OES) — 3 methods
- Plate method (pour plate) — 3 methods
- Atomic absorption spectrometry with electrochemical atomization (ETAAS) — 2 methods
- Culture method with biochemical and serological confirmation — 2 methods
- Electrochemical method — 2 methods
- Flame atomic absorption spectrometry (FAAS) — 2 methods
- Flotation method, microscopic — 2 methods
- Gas chromatography with flame ionization detection (GC-FID) — 2 methods
- and 11 more
Accreditation scope — test methods (132)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water intended for human consumption | Sampling for chemical and physical testing (including sensory testing) | PN-ISO 5667-5:2017-10 | ||
| 2 | Swimming pool water | Sampling for chemical and physical testing | PN-ISO 5667-5:2017-10 IS-7 edycja 3 z dnia 29.01.2018 r. | ||
| 3 | Water (including swimming pool water), bathing water, water intended for human consumption | Sampling for microbiological testing | PN-EN ISO 19458:2007 | ||
| 4 | Groundwater | Sampling for chemical and physical testing | PN-ISO 5667-11:2017-10 | ||
| 5 | Sewage sludge, waste o) code: 19 08 05 02 02 04 | Sampling for chemical and physical, microbiological and parasitological testing | PN-EN ISO 5667-13:2011 z wył. 6.3.5; 6.3.8.5. | ||
| 6 | Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 | Sampling for chemical and physical testing | PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8 | ||
| 7 | Soil | Sampling for chemical and physical testing | PN-R-04031:1997 | PN-ISO 10381-4:2007 | ||
| 8 | Surface water | Sampling for chemical and physical testing | PN-EN ISO 5667-6:2016-12 z wył. p. 7.6 | ||
| 9 | Wastewater (including rainwater and snowmelt water) | Sampling for chemical and physical testing Temperature of wastewater /of the collected wastewater sample Range (0,5 – 50) °C |
Manual method; Automatic method | PN-ISO 5667-10:2021-11 | PN-77/C-04584 | |
| 10 | Water, water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 | |
| 11 | Water, water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 | |
| 12 | Water, water intended for human consumption | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 13 | Water, water intended for human consumption | Most probable number, Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 14 | Water, water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 15 | Water, water intended for human consumption | Most probable number of intestinal enterococci | MPN method | ENTEROLERT-DW IDEXX wydanie 06-18085-07 z roku 2019 | |
| 16 | Water, water intended for human consumption | Total viable count at 22 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 17 | Water, water intended for human consumption | Total viable count at 36 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 18 | Water, water intended for human consumption | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 19 | Water, water intended for human consumption | Clostridium perfringens count including spores | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 20 | Water (including swimming pool water), water intended for human consumption | Coagulase-positive staphylococci count | Membrane filtration method | PN-Z-11001-3:2000 | |
| 21 | Water (including swimming pool water), water intended for human consumption | Count of bacteria of the genus Legionella Matrix A: Procedure 5 (medium A-BCYE), Procedure 7 (medium C-GVPC) |
Membrane filtration method | PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12 | |
| 22 | Water (including swimming pool water), water intended for human consumption | Count of bacteria of the genus Legionella Matrix B: Procedure 7(medium C-GVPC) |
Membrane filtration method | PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12 | |
| 23 | Water (including swimming pool water), water intended for human consumption | Count of bacteria of the genus Legionella Matrix A Procedure 1 (medium A-BCYE, medium B-BCYE+AB) |
Plate method (spread plate) | PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12 | |
| 24 | Water (including swimming pool water), water intended for human consumption | Count of bacteria of the genus Legionella Matrix B: Procedure 1 (medium C –GVPC) |
Plate method (spread plate) | PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12 | |
| 25 | Swimming pool water | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 | |
| 26 | Swimming pool water | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 | |
| 27 | Swimming pool water | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 28 | Swimming pool water | Total viable count at 36 °C | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 29 | Bathing water | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 | |
| 30 | Bathing water | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 31 | Water, bathing water | Most probable number, Escherichia coli | MPN method | PN-EN ISO 9308-3:2002 | |
| 32 | Sewage sludge, waste o) code: 19 08 05 | Presence of bacteria of the genus, Salmonella | Culture method with biochemical and serological confirmation | PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020- 09 | |
| 33 | Sewage sludge, waste o) code: 19 08 05 | Presence and count of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp. Range od 1 ATT/kg s.m. |
Flotation method, microscopic | PN-Z-19005:2018 | |
| 34 | Water, wastewater | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 35 | Water, wastewater | Total suspended solids (TSS) Range (2,0 – 2000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 36 | Water, wastewater | Dry residue Range (10 – 2000) mg/l |
Gravimetric method | PN-78/C-04541 | |
| 37 | Water, wastewater | Dissolved solids concentration Range (10 – 1000) mg/l |
Gravimetric method | PN-EN 15216:2022-03 | |
| 38 | Water, wastewater | Chloride concentration Range (5,0 – 1000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 39 | Water, wastewater | Sulphate (VI) concentration Range (10 – 500) mg/l |
Gravimetric method | PN-ISO 9280:2002 | |
| 40 | Water, wastewater | Kjeldahl nitrogen concentration Range (0,50 – 250) mg/l |
Titrimetric method | PN-EN 25663:2001 | |
| 41 | Water, wastewater | Dissolved oxygen concentration Range (0,5 – 15,0) mg/l O2 |
Electrochemical method | PN-EN ISO 5814:2013-04E | |
| 42 | Water, wastewater | Ammonium nitrogen concentration Range (0,20 – 250) mg/l |
Titrimetric method | PN-ISO 5664:2002 | |
| 43 | Water, wastewater | Nitrate nitrogen concentration Range (0,050 – 100) mg/l |
Spectrophotometric method | PN-82/C-04576/08 | |
| 44 | Water, wastewater | Nitrite nitrogen concentration Range (0,007 – 2,0) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 45 | Water, wastewater | Total nitrogen concentration (calculated) | PN-73/C-04576/14 | ||
| 46 | Water, wastewater | Metal concentrations zinc (0,10 – 4,0) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN ISO 8288:2002 metoda A | |
| 47 | Water, wastewater | Chemical Oxygen Demand COD-Cr Range (10 – 9000) mg/l O2 |
Spectrophotometric method | PN-ISO 15705:2005 | |
| 48 | Water, wastewater | Dissolved oxygen concentration Range (0,5 – 15,0) mg/l O2 |
Titrimetric method | PN-EN 25813:1997 | |
| 49 | Water, wastewater | Mineral oil index Range (0,10 – 50) mg/l |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 9377-2:2003 | |
| 50 | Water, wastewater | Phenol index Range (0,005 – 0,10) mg/l |
Spectrophotometric method | PN-ISO 6439:1994 metoda B | |
| 51 | Water, wastewater | Total iron concentration Range (0,010 – 20,0) mg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016 | |
| 52 | Water, wastewater | Element concentration nickel (6,0 – 6000) μg/l copper (3,0 – 2000) μg/l lead (3,0 – 2500) μg/l cadmium (0,40 – 400) μg/l total chromium (2,0 – 2000) μg/l arsenic (3,0 – 2500) μg/l |
Atomic absorption spectrometry with electrochemical atomization (ETAAS) | PN-EN-ISO 15586:2005 | |
| 53 | Water, wastewater | Anion concentrations bromides (0,5 – 30) mg/l chlorides (1,0 – 2 500) mg/l sulfates (2,0 – 2 500) mg/l nitrates (0,10 – 100) mg/l fluorides (0,10 – 10) mg/l |
Ion chromatography with conductometric detection (IC–CD) | PN-EN ISO 10304-1:2009 +AC:2012 | |
| 54 | Water, wastewater | Biochemical oxygen demand BOD5 Range (1 – 6000) mg/l O2 |
Electrochemical method; Optical method | PN-EN ISO 5815-1:2019-12 | |
| 55 | Water, wastewater | Biochemical oxygen demand BOD5 Range (0,60 – 7,0) mg/l O2 |
Electrochemical method | PN-EN 1899-2:2002 | |
| 56 | Water, wastewater | Orthophosphate concentration Range (0,040 – 50,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 p.4 | |
| 57 | Water, wastewater | Total phosphorus concentration Range (0,040 – 50,0) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 | |
| 58 | Water, wastewater | Sodium concentration Range (5,0 – 500) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 9964-1:1994+Ap1:2009 | PN-ISO 9964-1/Ak:1997 | |
| 59 | Water, wastewater | Free cyanide concentration Range (0,03 – 0,6) mg/l |
Spectrophotometric method | Test HACH nr LCK 315 edycja 2 z 08/2025 | |
| 60 | Water, wastewater | Electrical conductivity Range (25 – 3000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 61 | Water, wastewater | Free chlorine concentration Range (0,05 – 2,0) mg/l |
Spectrophotometric method | PN-EN ISO 7393-2:2018-04 | |
| 62 | Water, wastewater | Total chlorine concentration Range (0,05 – 2,0) mg/l |
Spectrophotometric method | PN-EN ISO 7393-2:2018-04 | |
| 63 | Water, wastewater | Combined chlorine concentration (calculated) | PN-EN ISO 7393-2:2018-04 | ||
| 64 | Water, wastewater | Chloramine concentration (calculated) | PN-EN ISO 7393-2:2018-04 | ||
| 65 | Water, wastewater | Element concentration Nickel (0,0020 – 2,0) mg/l Copper (0,050 – 2,0) mg/l Lead (0,0010 – 2,5) mg/l Cadmium (0,0005 – 1,0) mg/l Chromium (0,010 – 2,0) mg/l Arsenic (0,010 – 2,5) mg/l Manganese (0,0050 – 2,0) mg/l Iron (0,010 – 20) mg/l Zinc (0,100 - 10,0) mg/l Boron (0,100 – 15,0) mg/l Aluminium (0,010 – 4,0) mg/l Tin (0,020 – 4,0) mg/l Antimony (0,050 – 1,0) mg/l Barium (0,0010 - 4,0) mg/l Molybdenum (0,030 - 2,0) mg/l Mercury (0,005 – 0,250) mg/l Selenium ( 0,010 – 2,0) mg/l Silver (0,0010 – 1,0) mg/l Vanadium (0,050 - 4,0) mg/l Titanium (0,050 - 2,0) mg/l Beryllium (0,100 – 2,0) mg/l Cobalt (0,050 - 2,0) mg/l Magnesium (1,0 – 200) mg/l Calcium (1,0 – 200) mg/l Sodium (1,0 – 200) mg/l Potassium (1,0 – 200) mg/l Phosphorus (0,010 – 50,0) mg/l Total hardness (calculated) |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN ISO 11885:2009 | |
| 66 | Water, water intended for human consumption | Element concentration Mercury (0,40 – 10,0) μg/l Arsenic (1,0 – 15,0) μg/l Antimony (1,0 – 15,0) μg/l Selenium (1,0 – 15,0) μg/l |
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) | PN-EN ISO 11885:2009 | |
| 67 | Water, water intended for human consumption | Total organic carbon concentration Range (2,0 – 30,0) mg/l |
Spectrophotometric method | Test Nanocolor OWO 30 NEO nr 985048 wydanie 12.2024 | |
| 68 | Rainwater and snowmelt water | Total suspended solids (TSS) Range (2,0 – 2000) mg/l |
Gravimetric method | PN-EN 872:2007+Ap1:2007 | |
| 69 | Rainwater and snowmelt water | Mineral oil index Range (0,10 – 50) mg/l |
Gas chromatography with flame ionization detection (GC-FID) | PN-EN ISO 9377-2:2003 | |
| 70 | Wastewater | Anionic surfactant concentration. Range (0,050 – 20) mg/l |
Spectrophotometric method | PN-EN 903:2002 | |
| 71 | Wastewater | Concentration of substances extractable with petroleum ether. Range (10 – 200) mg/l |
Gravimetric method | PS-3 edycja 4 z dnia 22.02.2013 r. | |
| 72 | Wastewater | Chromium(VI) concentration Range (0,010 – 1,0) mg/l |
Spectrophotometric method | PN-77/C-04604/08 | |
| 73 | Wastewater | Non-ionic surfactant concentration Range (0,20-100) mg/l |
Spectrophotometric method | PN-ISO 7875-2:2002 | |
| 74 | Water | Turbidity Range (0,10 – 100) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 75 | Water | Magnesium concentration (calculated) | PN-99/C-04554/04 załącznik A | ||
| 76 | Water | Total content of calcium and magnesium (total hardness) Range (7 – 1000) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 77 | Water | Total alkalinity Range (0,40 – 20) mmol/l |
Titrimetric method | PN-EN ISO 9963-1:2001+Ap1:2004 | |
| 78 | Water | Bicarbonate concentration (calculated) | PN-EN ISO 9963-1:2001+Ap1:2004 | ||
| 79 | Water | Carbonate hardness, Non-carbonate hardness (calculated) | PN-EN ISO 9963-1:2001+Ap1:2004 | PN-ISO 6059:1999 | ||
| 80 | Water | Chromium(VI) concentration Range (0,005 – 0,050) mg/l |
Spectrophotometric method | PN-EN ISO 18412:2007 | |
| 81 | Water | Aluminium concentration Range (0,040 – 1,0) mg/l |
Spectrophotometric method | PN-92/C-04605/02 | |
| 82 | Water | Boron concentration Range (0,50 – 2,0) mg/l |
Spectrophotometric method | PN-75/C-04563.01 | |
| 83 | Water | Permanganate index Range (0,50 – 10) mg /l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 84 | Water | Ammonium ion concentration Range (0,030 – 2,6) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 85 | Water | Presence of foreign taste Taste threshold number TFN Range 1 – 4 |
Qualitative method; Simplified paired method, non-forced choice | PN-EN 1622:2006 | |
| 86 | Water | Presence of foreign odour Odour threshold number TON Range 1 – 4 |
Qualitative method; Simplified paired method, non-forced choice | PN-EN 1622:2006 | |
| 87 | Water | Manganese concentration Range (1,5 – 2000) μg/l |
Atomic absorption spectrometry with electrochemical atomization (ETAAS) | PN-EN-ISO 15586:2005 | |
| 88 | Water | Colour Range (2,0 – 70) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012+Ap1:2015 metoda C | |
| 89 | Water | Calcium concentration Range (0,05 – 2,5) mmol/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 90 | Water | Pesticide concentrations: aldrin dieldrin heptachlor Range (0,01-1,0) μg/l p, p’- DDD p, p’- DDE p, p’- DDT endrin alpha- HCH beta- HCH delta- HCH gamma- HCH alpha-endosulfan beta-endosulfan heptachlor epoxide endrin aldehyde methoxychlor Range (0,020-1,0) μg/l Sum of pesticide concentrations (calculated) |
Gas chromatography with electron capture detection (GC-ECD) | PN-EN ISO 6468:2002 | |
| 91 | Water | Trihalomethanes (THM) concentration trichloromethane (chloroform) Range (1,5 – 100) μg/l bromodichloromethane (1,5– 100) μg/l dibromochloromethane (1,5 – 100) μg/l tribromomethane (bromoform) (1,5 – 100) μg/l Sum of trihalomethane (THM) concentrations (calculated) |
Gas chromatography with electron capture detection (GC-ECD) | PN-EN ISO 10301:2002 | |
| 92 | Water | Chlorate, chlorite concentration Range (0,10 – 2,0) mg/l Sum of chlorates, chlorites (calculated) |
By ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-4:2022-08 | |
| 93 | Swimming pool water | Free chlorine concentration Range (0,05 – 2,0) mg/l |
Spectrophotometric method | PN-EN ISO 7393-2:2018-04 | |
| 94 | Swimming pool water | Total chlorine concentration Range (0,05 – 2,0) mg/l |
Spectrophotometric method | PN-EN ISO 7393-2:2018-04 | |
| 95 | Swimming pool water | Combined chlorine concentration (calculated) | PN-EN ISO 7393-2:2018-04 | ||
| 96 | Swimming pool water | Permanganate index Range (0,50 – 10) mg/l O2 |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 97 | Swimming pool water | Anion concentrations nitrates (0,10 – 100) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009+AC:2012 | |
| 98 | Swimming pool water | Turbidity Range (0,10 – 100) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 99 | Swimming pool water | Aluminium concentration Range (0,040 – 1,0) mg/l |
Spectrophotometric method | PN-92/C-04605/02 | |
| 100 | Swimming pool water | pH Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 101 | Swimming pool water | Oxidation-reduction potential + (redox) ref. to Ag/AgCl 3,5 mol/l KCl Range (220 – 1000) mV |
Potentiometric method | PS-16 edycja 1 z dnia 05.07.2016 r. | |
| 102 | Swimming pool water | Trihalomethanes (THM) concentration trichloromethane (chloroform) Range (1,5 – 100) μg/l bromodichloromethane (1,5– 100) μg/l dibromochloromethane (1,5 – 100) μg/l tribromomethane (bromoform) (1,5 – 100) μg/l Sum of trihalomethane (THM) concentrations (calculated) |
Gas chromatography with electron capture detection (GC-ECD) | PN-EN ISO 10301:2002 | |
| 103 | Soil | pH - in KCl, pH - in CaCl2, pH - in H2O Range 2,0 – 12,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 104 | Soil | Element content Chromium (1,0 – 5000) mg/kg Zinc (10 – 10000) mg/kg Lead (0,1 – 5000) mg/kg Cadmium (0,05 – 50) mg/kg Nickel (0,2 – 5000) mg/kg Copper (5,0 – 5000) mg/kg Mercury (0,5 – 50) mg/kg |
Inductively coupled plasma optical emission spectrometry (ICP-OES) | PN-EN 16170:2017-02 | |
| 105 | Soil | Available phosphorus content Range (1,0 – 50) mg/100g P2O5 |
Spectrophotometric method | PN-R-04023:1996 | |
| 106 | Sewage sludge | pH - in KCl, pH - in CaCl2, pH - in H2O Range 4,0 – 12,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 107 | Sewage sludge | Loss on ignition of dry matter (LOI) / Residue on ignition Range (1,0 – 99,0) % |
Gravimetric method | PN-EN 15935:2022-01 | |
| 108 | Sewage sludge | Dry matter / water content Range (1,0 – 99,0) % |
Gravimetric method | PN-EN 15934:2013-02 | |
| 109 | Sewage sludge | Kjeldahl nitrogen content Range (0,20 – 7,0) % |
Titrimetric method | PN-EN 13342:2002 | |
| 110 | Sewage sludge | Ammonium nitrogen content Range (0,10 – 100) g/kg |
Titrimetric method | PN-EN 14671:2007 | PN-ISO 5664:2002 | |
| 111 | Sewage sludge | Total phosphorus content Range (0,50 – 8,0) % |
Spectrophotometric method | PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 | |
| 112 | Sewage sludge | Calcium content Range (0,10 – 15) % Magnesium content Range (0,080 – 1,5) % |
Titrimetric method | PS-11 edycja 3 z dnia 22.02.2013 r. | |
| 113 | Sewage sludge | Element content Chromium (1,0 – 5000) mg/kg Zinc (10 – 10000) mg/kg Lead (0,1 – 5000) mg/kg Cadmium (0,05 – 50) mg/kg Nickel (0,2 – 5000) mg/kg Copper (5,0 – 5000) mg/kg Mercury (0,5 – 50) mg/kg Phosphorus (1,0 – 5000) mg/kg Magnesium (100 – 15 000) mg/kg Range (0,010 – 1,50) % Calcium (100 –150 000) mg/kg (0,010– 15,0) % |
Inductively coupled plasma optical emission spectrometry (ICP–OES) | PN-EN 16170:2017-02 | |
| 114 | Waste o) code: 19 08 05 | Sampling for chemical and physical, microbiological and parasitological testing | PN-EN ISO 5667-13:2011 z wył. 6.3.5, 6.3.8.5 | ||
| 115 | Waste o) code: 19 08 05 | pH - in KCl, pH - in CaCl2, pH - in H2O Range 4,0 – 12,0 |
Potentiometric method | PN-EN ISO 10390:2022-09 | |
| 116 | Waste o) code: 19 08 05 | Loss on ignition of dry matter (LOI)/ Residue on ignition Range (1,0 – 99,0) % |
Gravimetric method | PN-EN 15935:2022-01 | |
| 117 | Waste o) code: 19 08 05 | Dry matter / water content Range (1,0 – 99,0) % |
Gravimetric method | PN-EN 15934:2013-02 | |
| 118 | Waste o) code: 19 08 05 | Kjeldahl nitrogen content Range (0,20 – 7,0) % |
Titrimetric method | PN-EN 13342:2002 | |
| 119 | Waste o) code: 19 08 05 | Ammonium nitrogen content Range (0,10 – 100) g/kg |
Titrimetric method | PN-EN 14671:2007 | PN-ISO 5664:2002 | |
| 120 | Waste o) code: 19 08 05 | Total phosphorus content Range (0,50 – 8,0) % |
Spectrophotometric method | PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 | |
| 121 | Waste o) code: 19 08 05 | Calcium content Range (0,10 – 15) % |
Titrimetric method | PS-11 edycja 3 z dnia 22.02.2013 r. | |
| 122 | Waste o) code: 19 08 05 | Magnesium content Range (0,080 – 1,5) % |
Titrimetric method | PS-11 edycja 3 z dnia 22.02.2013 r. | |
| 123 | Waste o) code: 19 08 05 | Element content Chromium (1,0 – 5000) mg/kg Zinc (10 – 10000) mg/kg Lead (0,1 – 5000) mg/kg Cadmium (0,05 – 50) mg/kg Nickel (0,2 – 5000) mg/kg Copper (5,0 – 5000) mg/kg Mercury (0,5 – 50) mg/kg Phosphorus (1,0 – 5000) mg/kg Magnesium (100 – 15 000) mg/kg Range (0,010 – 1,50) % Calcium (100 – 150 000) mg/kg (0,010– 15,0) % |
Inductively coupled plasma optical emission spectrometry (ICP–OES) | PN-EN 16170:2017-02 | |
| 124 | Waste o) code: 19 08 05 | Presence and count of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp. Range od 1 ATT/kg s.m. |
Flotation method, microscopic | PN-Z-19005:2018 | |
| 125 | Waste o) code: 19 08 05 | Presence of bacteria of the genus, Salmonella | Culture method with biochemical and serological confirmation | PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020- 09 | |
| 126 | Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 | Sampling for chemical and physical testing | PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8 | ||
| 127 | Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 | Total dissolved solids (TDS) Range (10 – 7500) mg/kg |
Gravimetric method | PN-EN 15216:2022-03 | PN-EN 12457-4:2006 | |
| 128 | Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 | Sulfate content Range (100 – 2500) mg/kg |
Gravimetric method | PN-ISO 9280:2002 | PN-EN 12457-4:2006 | |
| 129 | Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 | Chloride content Range (50 – 10000) mg/kg |
Titrimetric method | PN-ISO 9297:1994 | PN-EN 12457-4:2006 | |
| 130 | Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 | Anion content sulfates (100 – 2500) mg/kg chlorides (10 – 10000) mg/kg fluorides (1,0 – 100) mg/kg |
Ion chromatography with conductometric detection (IC–CD) | PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006 | |
| 131 | Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 | Element content nickel (0,020 – 20,0) mg/kg copper (0,50 – 20,0) mg/kg lead (0,010 – 25,0) mg/kg cadmium (0,0050 – 10,0) mg/kg chromium (0,050 – 20,0) mg/kg arsenic (0,10 – 20,0) mg/kg zinc (1,00 – 100) mg/kg barium (0,010 – 40,0) mg/kg molybdenum (0,30 – 20,0) mg/kg selenium (0,10 – 20,0) mg/kg |
Inductively coupled plasma optical emission spectrometry (ICP–OES) | PN-EN ISO 11885:2009 | PN-EN 12457-4:2006 | |
| 132 | Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 | Element content mercury (0,0040- 0,10) mg/kg antimony (0,010 - 0,15) mg/kg |
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) | PN-EN ISO 11885:2009 | PN-EN 12457-4:2006 | |
Reference standards (91)
ENTEROLERT-DW IDEXX wydanie 06-18085-07 z roku 2019
PN ISO 8288:2002 metoda A
PN-73/C-04576/14
PN-75/C-04563.01
PN-77/C-04584
PN-77/C-04604/08
PN-78/C-04541
PN-82/C-04576/08
PN-92/C-04605/02
PN-99/C-04554/04 załącznik A
PN-EN 12457-4:2006
PN-EN 13342:2002
PN-EN 14671:2007
PN-EN 14672:2006
PN-EN 15216:2022-03
PN-EN 15934:2013-02
PN-EN 15935:2022-01
PN-EN 16170:2017-02
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 25813:1997
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10301:2002
PN-EN ISO 10304-1:2009 +AC:2012
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10304-4:2022-08
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08
PN-EN ISO 11731:2017-08 /Ap1:2019-12
PN-EN ISO 11885:2009
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 18412:2007
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8
PN-EN ISO 5667-13:2011 z wył. 6.3.5, 6.3.8.5
PN-EN ISO 5667-13:2011 z wył. 6.3.5; 6.3.8.5.
PN-EN ISO 5667-6:2016-12 z wył. p. 7.6
PN-EN ISO 5814:2013-04E
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6468:2002
PN-EN ISO 6579-1:2017-04
PN-EN ISO 6579-1:2017-04/ A1:2020- 09
PN-EN ISO 6579-1:2017-04/A1:2020- 09
PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 p.4
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7887:2012+Ap1:2015 metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12 /A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9308-3:2002
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001+Ap1:2004
PN-EN-ISO 15586:2005
PN-ISO 10381-4:2007
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10
PN-ISO 5667-5:2017-10
PN-ISO 5667-5:2017-10 IS-7 edycja 3 z dnia 29.01.2018 r.
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016
PN-ISO 6439:1994 metoda B
PN-ISO 7150-1:2002
PN-ISO 7875-2:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9964-1/Ak:1997
PN-ISO 9964-1:1994+Ap1:2009
PN-R-04023:1996
PN-R-04031:1997
PN-Z-11001-3:2000
PN-Z-19005:2018
PS-11 edycja 3 z dnia 22.02.2013 r.
PS-16 edycja 1 z dnia 05.07.2016 r.
PS-3 edycja 4 z dnia 22.02.2013 r.
Test HACH nr LCK 315 edycja 2 z 08/2025
Test Nanocolor OWO 30 NEO nr 985048 wydanie 12.2024