🇵🇱 „EKO-SERWIS” s.c. PL

PCA AB 667 • Łódź, Poland • 132 methods

Water & wastewaterEnvironmentMicrobiologyMaterials & polymers

„EKO-SERWIS” s.c. is a laboratory accredited by PCA under number AB 667 (Łódź, Poland). Its accreditation scope covers 132 test methods in the following areas: Water & wastewater, Environment, Microbiology, Materials & polymers. Test objects include: Water, wastewater, Water, Swimming pool water, Waste o) code: 19 08 05. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.

At a glance

  • Accreditation number: PCA AB 667
  • Methods in scope: 132
  • Types of test objects: 20
  • Techniques used: 26
  • City: Łódź, Poland
Accreditation number
AB 667
Accreditation body
PCA
Address
Dorota Markowska, Maciej Markowski, ul. Wierzbowa 48, 90-133 Łódź
City
Łódź, Poland

What this laboratory tests (20)

Analytical techniques used (26)

Accreditation scope — test methods (132)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10
2 Swimming pool water Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 IS-7 edycja 3 z dnia 29.01.2018 r.
3 Water (including swimming pool water), bathing water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007
4 Groundwater Sampling for chemical and physical testing PN-ISO 5667-11:2017-10
5 Sewage sludge, waste o) code: 19 08 05 02 02 04 Sampling for chemical and physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011 z wył. 6.3.5; 6.3.8.5.
6 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8
7 Soil Sampling for chemical and physical testing PN-R-04031:1997 | PN-ISO 10381-4:2007
8 Surface water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wył. p. 7.6
9 Wastewater (including rainwater and snowmelt water) Sampling for chemical and physical testing
Temperature of wastewater /of the collected wastewater sample Range (0,5 – 50) °C
Manual method; Automatic method PN-ISO 5667-10:2021-11 | PN-77/C-04584
10 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
11 Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
12 Water, water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
13 Water, water intended for human consumption Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
14 Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
15 Water, water intended for human consumption Most probable number of intestinal enterococci MPN method ENTEROLERT-DW IDEXX wydanie 06-18085-07 z roku 2019
16 Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
17 Water, water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
18 Water, water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
19 Water, water intended for human consumption Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10
20 Water (including swimming pool water), water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000
21 Water (including swimming pool water), water intended for human consumption Count of bacteria of the genus Legionella
Matrix A: Procedure 5 (medium A-BCYE), Procedure 7 (medium C-GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
22 Water (including swimming pool water), water intended for human consumption Count of bacteria of the genus Legionella
Matrix B: Procedure 7(medium C-GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
23 Water (including swimming pool water), water intended for human consumption Count of bacteria of the genus Legionella
Matrix A Procedure 1 (medium A-BCYE, medium B-BCYE+AB)
Plate method (spread plate) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
24 Water (including swimming pool water), water intended for human consumption Count of bacteria of the genus Legionella
Matrix B: Procedure 1 (medium C –GVPC)
Plate method (spread plate) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12
25 Swimming pool water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
26 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
27 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
28 Swimming pool water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
29 Bathing water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04
30 Bathing water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
31 Water, bathing water Most probable number, Escherichia coli MPN method PN-EN ISO 9308-3:2002
32 Sewage sludge, waste o) code: 19 08 05 Presence of bacteria of the genus, Salmonella Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020- 09
33 Sewage sludge, waste o) code: 19 08 05 Presence and count of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp.
Range od 1 ATT/kg s.m.
Flotation method, microscopic PN-Z-19005:2018
34 Water, wastewater pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
35 Water, wastewater Total suspended solids (TSS)
Range (2,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
36 Water, wastewater Dry residue
Range (10 – 2000) mg/l
Gravimetric method PN-78/C-04541
37 Water, wastewater Dissolved solids concentration
Range (10 – 1000) mg/l
Gravimetric method PN-EN 15216:2022-03
38 Water, wastewater Chloride concentration
Range (5,0 – 1000) mg/l
Titrimetric method PN-ISO 9297:1994
39 Water, wastewater Sulphate (VI) concentration
Range (10 – 500) mg/l
Gravimetric method PN-ISO 9280:2002
40 Water, wastewater Kjeldahl nitrogen concentration
Range (0,50 – 250) mg/l
Titrimetric method PN-EN 25663:2001
41 Water, wastewater Dissolved oxygen concentration
Range (0,5 – 15,0) mg/l O2
Electrochemical method PN-EN ISO 5814:2013-04E
42 Water, wastewater Ammonium nitrogen concentration
Range (0,20 – 250) mg/l
Titrimetric method PN-ISO 5664:2002
43 Water, wastewater Nitrate nitrogen concentration
Range (0,050 – 100) mg/l
Spectrophotometric method PN-82/C-04576/08
44 Water, wastewater Nitrite nitrogen concentration
Range (0,007 – 2,0) mg/l
Spectrophotometric method PN-EN 26777:1999
45 Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14
46 Water, wastewater Metal concentrations
zinc (0,10 – 4,0) mg/l
Flame atomic absorption spectrometry (FAAS) PN ISO 8288:2002 metoda A
47 Water, wastewater Chemical Oxygen Demand
COD-Cr Range (10 – 9000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
48 Water, wastewater Dissolved oxygen concentration
Range (0,5 – 15,0) mg/l O2
Titrimetric method PN-EN 25813:1997
49 Water, wastewater Mineral oil index
Range (0,10 – 50) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
50 Water, wastewater Phenol index
Range (0,005 – 0,10) mg/l
Spectrophotometric method PN-ISO 6439:1994 metoda B
51 Water, wastewater Total iron concentration
Range (0,010 – 20,0) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016
52 Water, wastewater Element concentration
nickel (6,0 – 6000) μg/l copper (3,0 – 2000) μg/l lead (3,0 – 2500) μg/l cadmium (0,40 – 400) μg/l total chromium (2,0 – 2000) μg/l arsenic (3,0 – 2500) μg/l
Atomic absorption spectrometry with electrochemical atomization (ETAAS) PN-EN-ISO 15586:2005
53 Water, wastewater Anion concentrations
bromides (0,5 – 30) mg/l chlorides (1,0 – 2 500) mg/l sulfates (2,0 – 2 500) mg/l nitrates (0,10 – 100) mg/l fluorides (0,10 – 10) mg/l
Ion chromatography with conductometric detection (IC–CD) PN-EN ISO 10304-1:2009 +AC:2012
54 Water, wastewater Biochemical oxygen demand
BOD5 Range (1 – 6000) mg/l O2
Electrochemical method; Optical method PN-EN ISO 5815-1:2019-12
55 Water, wastewater Biochemical oxygen demand
BOD5 Range (0,60 – 7,0) mg/l O2
Electrochemical method PN-EN 1899-2:2002
56 Water, wastewater Orthophosphate concentration
Range (0,040 – 50,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 p.4
57 Water, wastewater Total phosphorus concentration
Range (0,040 – 50,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
58 Water, wastewater Sodium concentration
Range (5,0 – 500) mg/l
Flame atomic absorption spectrometry (FAAS) PN-ISO 9964-1:1994+Ap1:2009 | PN-ISO 9964-1/Ak:1997
59 Water, wastewater Free cyanide concentration
Range (0,03 – 0,6) mg/l
Spectrophotometric method Test HACH nr LCK 315 edycja 2 z 08/2025
60 Water, wastewater Electrical conductivity
Range (25 – 3000) μS/cm
Conductometric method PN-EN 27888:1999
61 Water, wastewater Free chlorine concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
62 Water, wastewater Total chlorine concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
63 Water, wastewater Combined chlorine concentration (calculated) PN-EN ISO 7393-2:2018-04
64 Water, wastewater Chloramine concentration (calculated) PN-EN ISO 7393-2:2018-04
65 Water, wastewater Element concentration
Nickel (0,0020 – 2,0) mg/l Copper (0,050 – 2,0) mg/l Lead (0,0010 – 2,5) mg/l Cadmium (0,0005 – 1,0) mg/l Chromium (0,010 – 2,0) mg/l Arsenic (0,010 – 2,5) mg/l Manganese (0,0050 – 2,0) mg/l Iron (0,010 – 20) mg/l Zinc (0,100 - 10,0) mg/l Boron (0,100 – 15,0) mg/l Aluminium (0,010 – 4,0) mg/l Tin (0,020 – 4,0) mg/l Antimony (0,050 – 1,0) mg/l Barium (0,0010 - 4,0) mg/l Molybdenum (0,030 - 2,0) mg/l Mercury (0,005 – 0,250) mg/l Selenium ( 0,010 – 2,0) mg/l Silver (0,0010 – 1,0) mg/l Vanadium (0,050 - 4,0) mg/l Titanium (0,050 - 2,0) mg/l Beryllium (0,100 – 2,0) mg/l Cobalt (0,050 - 2,0) mg/l Magnesium (1,0 – 200) mg/l Calcium (1,0 – 200) mg/l Sodium (1,0 – 200) mg/l Potassium (1,0 – 200) mg/l Phosphorus (0,010 – 50,0) mg/l Total hardness (calculated)
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
66 Water, water intended for human consumption Element concentration
Mercury (0,40 – 10,0) μg/l Arsenic (1,0 – 15,0) μg/l Antimony (1,0 – 15,0) μg/l Selenium (1,0 – 15,0) μg/l
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) PN-EN ISO 11885:2009
67 Water, water intended for human consumption Total organic carbon concentration
Range (2,0 – 30,0) mg/l
Spectrophotometric method Test Nanocolor OWO 30 NEO nr 985048 wydanie 12.2024
68 Rainwater and snowmelt water Total suspended solids (TSS)
Range (2,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
69 Rainwater and snowmelt water Mineral oil index
Range (0,10 – 50) mg/l
Gas chromatography with flame ionization detection (GC-FID) PN-EN ISO 9377-2:2003
70 Wastewater Anionic surfactant concentration.
Range (0,050 – 20) mg/l
Spectrophotometric method PN-EN 903:2002
71 Wastewater Concentration of substances extractable with petroleum ether.
Range (10 – 200) mg/l
Gravimetric method PS-3 edycja 4 z dnia 22.02.2013 r.
72 Wastewater Chromium(VI) concentration
Range (0,010 – 1,0) mg/l
Spectrophotometric method PN-77/C-04604/08
73 Wastewater Non-ionic surfactant concentration
Range (0,20-100) mg/l
Spectrophotometric method PN-ISO 7875-2:2002
74 Water Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
75 Water Magnesium concentration (calculated) PN-99/C-04554/04 załącznik A
76 Water Total content of calcium and magnesium (total hardness)
Range (7 – 1000) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
77 Water Total alkalinity
Range (0,40 – 20) mmol/l
Titrimetric method PN-EN ISO 9963-1:2001+Ap1:2004
78 Water Bicarbonate concentration (calculated) PN-EN ISO 9963-1:2001+Ap1:2004
79 Water Carbonate hardness, Non-carbonate hardness (calculated) PN-EN ISO 9963-1:2001+Ap1:2004 | PN-ISO 6059:1999
80 Water Chromium(VI) concentration
Range (0,005 – 0,050) mg/l
Spectrophotometric method PN-EN ISO 18412:2007
81 Water Aluminium concentration
Range (0,040 – 1,0) mg/l
Spectrophotometric method PN-92/C-04605/02
82 Water Boron concentration
Range (0,50 – 2,0) mg/l
Spectrophotometric method PN-75/C-04563.01
83 Water Permanganate index
Range (0,50 – 10) mg /l O2
Titrimetric method PN-EN ISO 8467:2001
84 Water Ammonium ion concentration
Range (0,030 – 2,6) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
85 Water Presence of foreign taste
Taste threshold number TFN Range 1 – 4
Qualitative method; Simplified paired method, non-forced choice PN-EN 1622:2006
86 Water Presence of foreign odour
Odour threshold number TON Range 1 – 4
Qualitative method; Simplified paired method, non-forced choice PN-EN 1622:2006
87 Water Manganese concentration
Range (1,5 – 2000) μg/l
Atomic absorption spectrometry with electrochemical atomization (ETAAS) PN-EN-ISO 15586:2005
88 Water Colour
Range (2,0 – 70) mg/l Pt
Spectrophotometric method PN-EN ISO 7887:2012+Ap1:2015 metoda C
89 Water Calcium concentration
Range (0,05 – 2,5) mmol/l
Titrimetric method PN-ISO 6058:1999
90 Water Pesticide concentrations:
aldrin dieldrin heptachlor Range (0,01-1,0) μg/l p, p’- DDD p, p’- DDE p, p’- DDT endrin alpha- HCH beta- HCH delta- HCH gamma- HCH alpha-endosulfan beta-endosulfan heptachlor epoxide endrin aldehyde methoxychlor Range (0,020-1,0) μg/l Sum of pesticide concentrations (calculated)
Gas chromatography with electron capture detection (GC-ECD) PN-EN ISO 6468:2002
91 Water Trihalomethanes (THM) concentration
trichloromethane (chloroform) Range (1,5 – 100) μg/l bromodichloromethane (1,5– 100) μg/l dibromochloromethane (1,5 – 100) μg/l tribromomethane (bromoform) (1,5 – 100) μg/l Sum of trihalomethane (THM) concentrations (calculated)
Gas chromatography with electron capture detection (GC-ECD) PN-EN ISO 10301:2002
92 Water Chlorate, chlorite concentration
Range (0,10 – 2,0) mg/l Sum of chlorates, chlorites (calculated)
By ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-4:2022-08
93 Swimming pool water Free chlorine concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
94 Swimming pool water Total chlorine concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2018-04
95 Swimming pool water Combined chlorine concentration (calculated) PN-EN ISO 7393-2:2018-04
96 Swimming pool water Permanganate index
Range (0,50 – 10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
97 Swimming pool water Anion concentrations
nitrates (0,10 – 100) mg/l
Ion chromatography with conductometric detection (IC-CD) PN-EN ISO 10304-1:2009+AC:2012
98 Swimming pool water Turbidity
Range (0,10 – 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
99 Swimming pool water Aluminium concentration
Range (0,040 – 1,0) mg/l
Spectrophotometric method PN-92/C-04605/02
100 Swimming pool water pH
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10523:2012
101 Swimming pool water Oxidation-reduction potential + (redox) ref. to Ag/AgCl 3,5 mol/l KCl
Range (220 – 1000) mV
Potentiometric method PS-16 edycja 1 z dnia 05.07.2016 r.
102 Swimming pool water Trihalomethanes (THM) concentration
trichloromethane (chloroform) Range (1,5 – 100) μg/l bromodichloromethane (1,5– 100) μg/l dibromochloromethane (1,5 – 100) μg/l tribromomethane (bromoform) (1,5 – 100) μg/l Sum of trihalomethane (THM) concentrations (calculated)
Gas chromatography with electron capture detection (GC-ECD) PN-EN ISO 10301:2002
103 Soil pH - in KCl, pH - in CaCl2, pH - in H2O
Range 2,0 – 12,0
Potentiometric method PN-EN ISO 10390:2022-09
104 Soil Element content
Chromium (1,0 – 5000) mg/kg Zinc (10 – 10000) mg/kg Lead (0,1 – 5000) mg/kg Cadmium (0,05 – 50) mg/kg Nickel (0,2 – 5000) mg/kg Copper (5,0 – 5000) mg/kg Mercury (0,5 – 50) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN 16170:2017-02
105 Soil Available phosphorus content
Range (1,0 – 50) mg/100g P2O5
Spectrophotometric method PN-R-04023:1996
106 Sewage sludge pH - in KCl, pH - in CaCl2, pH - in H2O
Range 4,0 – 12,0
Potentiometric method PN-EN ISO 10390:2022-09
107 Sewage sludge Loss on ignition of dry matter (LOI) / Residue on ignition
Range (1,0 – 99,0) %
Gravimetric method PN-EN 15935:2022-01
108 Sewage sludge Dry matter / water content
Range (1,0 – 99,0) %
Gravimetric method PN-EN 15934:2013-02
109 Sewage sludge Kjeldahl nitrogen content
Range (0,20 – 7,0) %
Titrimetric method PN-EN 13342:2002
110 Sewage sludge Ammonium nitrogen content
Range (0,10 – 100) g/kg
Titrimetric method PN-EN 14671:2007 | PN-ISO 5664:2002
111 Sewage sludge Total phosphorus content
Range (0,50 – 8,0) %
Spectrophotometric method PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
112 Sewage sludge Calcium content
Range (0,10 – 15) % Magnesium content Range (0,080 – 1,5) %
Titrimetric method PS-11 edycja 3 z dnia 22.02.2013 r.
113 Sewage sludge Element content
Chromium (1,0 – 5000) mg/kg Zinc (10 – 10000) mg/kg Lead (0,1 – 5000) mg/kg Cadmium (0,05 – 50) mg/kg Nickel (0,2 – 5000) mg/kg Copper (5,0 – 5000) mg/kg Mercury (0,5 – 50) mg/kg Phosphorus (1,0 – 5000) mg/kg Magnesium (100 – 15 000) mg/kg Range (0,010 – 1,50) % Calcium (100 –150 000) mg/kg (0,010– 15,0) %
Inductively coupled plasma optical emission spectrometry (ICP–OES) PN-EN 16170:2017-02
114 Waste o) code: 19 08 05 Sampling for chemical and physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011 z wył. 6.3.5, 6.3.8.5
115 Waste o) code: 19 08 05 pH - in KCl, pH - in CaCl2, pH - in H2O
Range 4,0 – 12,0
Potentiometric method PN-EN ISO 10390:2022-09
116 Waste o) code: 19 08 05 Loss on ignition of dry matter (LOI)/ Residue on ignition
Range (1,0 – 99,0) %
Gravimetric method PN-EN 15935:2022-01
117 Waste o) code: 19 08 05 Dry matter / water content
Range (1,0 – 99,0) %
Gravimetric method PN-EN 15934:2013-02
118 Waste o) code: 19 08 05 Kjeldahl nitrogen content
Range (0,20 – 7,0) %
Titrimetric method PN-EN 13342:2002
119 Waste o) code: 19 08 05 Ammonium nitrogen content
Range (0,10 – 100) g/kg
Titrimetric method PN-EN 14671:2007 | PN-ISO 5664:2002
120 Waste o) code: 19 08 05 Total phosphorus content
Range (0,50 – 8,0) %
Spectrophotometric method PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
121 Waste o) code: 19 08 05 Calcium content
Range (0,10 – 15) %
Titrimetric method PS-11 edycja 3 z dnia 22.02.2013 r.
122 Waste o) code: 19 08 05 Magnesium content
Range (0,080 – 1,5) %
Titrimetric method PS-11 edycja 3 z dnia 22.02.2013 r.
123 Waste o) code: 19 08 05 Element content
Chromium (1,0 – 5000) mg/kg Zinc (10 – 10000) mg/kg Lead (0,1 – 5000) mg/kg Cadmium (0,05 – 50) mg/kg Nickel (0,2 – 5000) mg/kg Copper (5,0 – 5000) mg/kg Mercury (0,5 – 50) mg/kg Phosphorus (1,0 – 5000) mg/kg Magnesium (100 – 15 000) mg/kg Range (0,010 – 1,50) % Calcium (100 – 150 000) mg/kg (0,010– 15,0) %
Inductively coupled plasma optical emission spectrometry (ICP–OES) PN-EN 16170:2017-02
124 Waste o) code: 19 08 05 Presence and count of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp.
Range od 1 ATT/kg s.m.
Flotation method, microscopic PN-Z-19005:2018
125 Waste o) code: 19 08 05 Presence of bacteria of the genus, Salmonella Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020- 09
126 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8
127 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Total dissolved solids (TDS)
Range (10 – 7500) mg/kg
Gravimetric method PN-EN 15216:2022-03 | PN-EN 12457-4:2006
128 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Sulfate content
Range (100 – 2500) mg/kg
Gravimetric method PN-ISO 9280:2002 | PN-EN 12457-4:2006
129 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Chloride content
Range (50 – 10000) mg/kg
Titrimetric method PN-ISO 9297:1994 | PN-EN 12457-4:2006
130 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Anion content
sulfates (100 – 2500) mg/kg chlorides (10 – 10000) mg/kg fluorides (1,0 – 100) mg/kg
Ion chromatography with conductometric detection (IC–CD) PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006
131 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Element content
nickel (0,020 – 20,0) mg/kg copper (0,50 – 20,0) mg/kg lead (0,010 – 25,0) mg/kg cadmium (0,0050 – 10,0) mg/kg chromium (0,050 – 20,0) mg/kg arsenic (0,10 – 20,0) mg/kg zinc (1,00 – 100) mg/kg barium (0,010 – 40,0) mg/kg molybdenum (0,30 – 20,0) mg/kg selenium (0,10 – 20,0) mg/kg
Inductively coupled plasma optical emission spectrometry (ICP–OES) PN-EN ISO 11885:2009 | PN-EN 12457-4:2006
132 Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Element content
mercury (0,0040- 0,10) mg/kg antimony (0,010 - 0,15) mg/kg
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-4:2006

Reference standards (91)

ENTEROLERT-DW IDEXX wydanie 06-18085-07 z roku 2019
PN ISO 8288:2002 metoda A
PN-73/C-04576/14
PN-75/C-04563.01
PN-77/C-04584
PN-77/C-04604/08
PN-78/C-04541
PN-82/C-04576/08
PN-92/C-04605/02
PN-99/C-04554/04 załącznik A
PN-EN 12457-4:2006
PN-EN 13342:2002
PN-EN 14671:2007
PN-EN 14672:2006
PN-EN 15216:2022-03
PN-EN 15934:2013-02
PN-EN 15935:2022-01
PN-EN 16170:2017-02
PN-EN 1622:2006
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 25813:1997
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10301:2002
PN-EN ISO 10304-1:2009 +AC:2012
PN-EN ISO 10304-1:2009+AC:2012
PN-EN ISO 10304-4:2022-08
PN-EN ISO 10390:2022-09
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08
PN-EN ISO 11731:2017-08 /Ap1:2019-12
PN-EN ISO 11885:2009
PN-EN ISO 14189:2016-10
PN-EN ISO 16266:2009
PN-EN ISO 18412:2007
PN-EN ISO 19458:2007
PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8
PN-EN ISO 5667-13:2011 z wył. 6.3.5, 6.3.8.5
PN-EN ISO 5667-13:2011 z wył. 6.3.5; 6.3.8.5.
PN-EN ISO 5667-6:2016-12 z wył. p. 7.6
PN-EN ISO 5814:2013-04E
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6468:2002
PN-EN ISO 6579-1:2017-04
PN-EN ISO 6579-1:2017-04/ A1:2020- 09
PN-EN ISO 6579-1:2017-04/A1:2020- 09
PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 p.4
PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7393-2:2018-04
PN-EN ISO 7887:2012+Ap1:2015 metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12 /A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9308-3:2002
PN-EN ISO 9377-2:2003
PN-EN ISO 9963-1:2001+Ap1:2004
PN-EN-ISO 15586:2005
PN-ISO 10381-4:2007
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-11:2017-10
PN-ISO 5667-5:2017-10
PN-ISO 5667-5:2017-10 IS-7 edycja 3 z dnia 29.01.2018 r.
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016
PN-ISO 6439:1994 metoda B
PN-ISO 7150-1:2002
PN-ISO 7875-2:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-ISO 9964-1/Ak:1997
PN-ISO 9964-1:1994+Ap1:2009
PN-R-04023:1996
PN-R-04031:1997
PN-Z-11001-3:2000
PN-Z-19005:2018
PS-11 edycja 3 z dnia 22.02.2013 r.
PS-16 edycja 1 z dnia 05.07.2016 r.
PS-3 edycja 4 z dnia 22.02.2013 r.
Test HACH nr LCK 315 edycja 2 z 08/2025
Test Nanocolor OWO 30 NEO nr 985048 wydanie 12.2024