{"lab":{"_id":"69ad52a3de79e566650fb368","accr_number":"AB 667","country":"PL","accr_body":"PCA","address":"Dorota Markowska, Maciej Markowski, ul. Wierzbowa 48, 90-133 Łódź","categories":["water","environment","microbiology","materials"],"city":"Łódź","imported_at":"2026-03-08T10:42:43.265Z","methods_count":132,"name":"„EKO-SERWIS” s.c.","parse_status":"parsed","parse_version":3,"pdf_files":["AB_667.pdf"],"scope_summary":"","search_text":"„eko-serwis” s.c. dorota markowska, maciej markowski, ul. wierzbowa 48, 90-133 łódź water microbiology other environment automotive pharma materials food electronics","status":"active","updated_at":"2026-03-08T14:51:34.336Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:34.336Z","location":{"type":"Point","coordinates":[19.456,51.7592]},"email_confidence":"high","email_mx":true,"email_source":"https://www.ekoserwis.info.pl/kontakt.php","fields_of_testing":[{"codes":"B/32/P","pl":"Badania biologiczne i biochemiczne i pobieranie próbek osadów, odpadów","en":"Biological and biochemical tests and sampling of sediments, waste"},{"codes":"C/28/P; C/29/P; C/30/P; C/31/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleby, osadów, odpadów","en":"Chemical tests and sampling of water, drinking water, sewage, soil, sediments, waste"},{"codes":"N/28/P; N/29/P;N/30/P; N/31/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, gleby, osadów, odpadów","en":"Tests of physical properties and sampling of water, drinking water, sewage, soil, sediments, waste"},{"codes":"K/28/P; K/29/P; K/32/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi, osadów, odpadów","en":"Microbiological tests and sampling of water, drinking water, sediments, waste"},{"codes":"P/32","pl":"Pobieranie próbek odpadów","en":"Sampling of waste"},{"codes":"Q/28","pl":"Badania sensoryczne wody","en":"Sensory tests of water"},{"codes":"Q/29/P","pl":"Badania sensoryczne i pobieranie próbek wody do spożycia przez ludzi","en":"Sensory tests and sampling of drinking water"}],"issue":{"no":"28","date":"14.11.2025"},"parse_date":"2026-07-20T07:09:47.023Z","parse_source":"script-pdfplumber","map_coord":[51.770002,19.479891],"map_geo":"nominatim-street","has_en":true,"category_counts":{"water":109,"environment":27,"microbiology":17,"materials":7,"petro":2},"category_scores":{"water":73.34,"environment":4.5,"microbiology":1.78,"materials":0.3,"petro":0.02},"has_zh":true},"methods":[{"_id":"6a5dc9bbf1c10c8ce825ddb5","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","test_object_en":"Water intended for human consumption","methodology":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","methodology_en":"Sampling for chemical and physical testing (including sensory testing)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych)","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych (w tym sensorycznych) PN-ISO 5667-5:2017-10","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) PN-ISO 5667-5:2017-10","search_zh":"生活饮用水 化学和物理检测采样（含感官检测） PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","methodology_zh":"化学和物理检测采样（含感官检测）"},{"_id":"6a5dc9bbf1c10c8ce825ddb6","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10 IS-7 edycja 3 z dnia 29.01.2018 r.","norm_bases":["PN-ISO 5667-5:2017-10 IS-7 edycja 3 z dnia 29.01.2018 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 IS-7 edycja 3 z dnia 29.01.2018 r. Woda na plywalniach Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10 IS-7 edycja 3 z dnia 29.01.2018 r.","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 IS-7 edycja 3 z dnia 29.01.2018 r.","methodology_zh":"化学与物理检测用样品采集","search_zh":"游泳池水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10 IS-7 edycja 3 z dnia 29.01.2018 r.","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825ddb7","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda z kąpielisk, woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), bathing water, water intended for human consumption","methodology":"Pobieranie próbek do badań mikrobiologicznych","methodology_en":"Sampling for microbiological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda z kąpielisk, woda do spożycia przez ludzi Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda (w tym woda na plywalniach), woda z kapielisk, woda do spozycia przez ludzi Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), bathing water, water intended for human consumption Sampling for microbiological testing PN-EN ISO 19458:2007","methodology_zh":"微生物检测用样品采集","search_zh":"微生物检测用样品采集 PN-EN ISO 19458:2007"},{"_id":"6a5dc9bbf1c10c8ce825ddb8","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Wody podziemne","test_object_en":"Groundwater","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-11:2017-10","norm_bases":["PN-ISO 5667-11:2017-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody podziemne Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-11:2017-10 Wody podziemne Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-11:2017-10","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Groundwater Sampling for chemical and physical testing PN-ISO 5667-11:2017-10","methodology_zh":"化学与物理检测用样品采集","search_zh":"地下水 化学与物理检测用样品采集 PN-ISO 5667-11:2017-10","test_object_zh":"地下水"},{"_id":"6a5dc9bbf1c10c8ce825ddb9","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Osady ściekowe, odpady o) kod: 19 08 05 02 02 04","test_object_en":"Sewage sludge, waste o) code: 19 08 05 02 02 04","methodology":"Pobieranie próbek do badań chemicznych i fizycznych, mikrobiologicznych i parazytologicznych","methodology_en":"Sampling for chemical and physical, microbiological and parasitological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych, mikrobiologicznych i parazytologicznych","reference":"PN-EN ISO 5667-13:2011 z wył. 6.3.5; 6.3.8.5.","norm_bases":["PN-EN ISO 5667-13:2011 z wył. 6.3.5; 6.3.8.5."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, odpady o) kod: 19 08 05 02 02 04 Pobieranie próbek do badań chemicznych i fizycznych, mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 z wył. 6.3.5; 6.3.8.5. Osady sciekowe, odpady o) kod: 19 08 05 02 02 04 Pobieranie probek do badan chemicznych i fizycznych, mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 z wyl. 6.3.5; 6.3.8.5.","categories":["water","environment","microbiology"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, waste o) code: 19 08 05 02 02 04 Sampling for chemical and physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011 z wył. 6.3.5; 6.3.8.5."},{"_id":"6a5dc9bbf1c10c8ce825ddba","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13","test_object_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8","norm_bases":["PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8 Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyl. 6.3.4; 6.3.5; 6.3.8","categories":["environment"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8","methodology_zh":"化学与物理检测用样品采集","search_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13 化学与物理检测用样品采集 PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8","test_object_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13"},{"_id":"6a5dc9bbf1c10c8ce825ddbb","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-R-04031:1997 | PN-ISO 10381-4:2007","norm_bases":["PN-R-04031:1997","PN-ISO 10381-4:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Pobieranie próbek do badań chemicznych i fizycznych PN-R-04031:1997 | PN-ISO 10381-4:2007 Gleba Pobieranie probek do badan chemicznych i fizycznych PN-R-04031:1997 | PN-ISO 10381-4:2007","categories":["environment"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Sampling for chemical and physical testing PN-R-04031:1997 | PN-ISO 10381-4:2007","methodology_zh":"化学与物理检测用样品采集","search_zh":"土壤 化学与物理检测用样品采集 PN-R-04031:1997 | PN-ISO 10381-4:2007","test_object_zh":"土壤"},{"_id":"6a5dc9bbf1c10c8ce825ddbc","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda powierzchniowa","test_object_en":"Surface water","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-6:2016-12 z wył. p. 7.6","norm_bases":["PN-EN ISO 5667-6:2016-12 z wył. p. 7.6"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda powierzchniowa Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wył. p. 7.6 Woda powierzchniowa Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-6:2016-12 z wyl. p. 7.6","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Surface water Sampling for chemical and physical testing PN-EN ISO 5667-6:2016-12 z wył. p. 7.6","methodology_zh":"化学与物理检测用样品采集","search_zh":"地表水 化学与物理检测用样品采集 PN-EN ISO 5667-6:2016-12 z wył. p. 7.6","test_object_zh":"地表水"},{"_id":"6a5dc9bbf1c10c8ce825ddbd","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Ścieki (w tym wody opadowe i roztopowe)","test_object_en":"Wastewater (including rainwater and snowmelt water)","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[{"name":"Temperatura ścieków /pobranej próbki ścieków"},{"name":"Zakres","range":"(0,5 – 50) °C"}],"parameters_en":[{"name":"Temperature of wastewater /of the collected wastewater sample"},{"name":"Range","range":"(0,5 – 50) °C"}],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"technique_en":"Manual method; Automatic method","computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków /pobranej próbki ścieków\nZakres (0,5 – 50) °C\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11 | PN-77/C-04584","norm_bases":["PN-ISO 5667-10:2021-11","PN-77/C-04584"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki (w tym wody opadowe i roztopowe) Pobieranie próbek do badań chemicznych i fizycznych\nZakres:\nTemperatura ścieków /pobranej próbki ścieków\nZakres (0,5 – 50) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584 Scieki (w tym wody opadowe i roztopowe) Pobieranie probek do badan chemicznych i fizycznych\nZakres:\nTemperatura sciekow /pobranej probki sciekow\nZakres (0,5 – 50) °C\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 | PN-77/C-04584","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater (including rainwater and snowmelt water) Sampling for chemical and physical testing Manual method; Automatic method Temperature of wastewater /of the collected wastewater sample Range PN-ISO 5667-10:2021-11 | PN-77/C-04584","methodology_zh":"化学与物理检测用样品采集","parameters_zh":[{"name":"Temperatura ścieków /pobranej próbki ścieków"},{"name":"范围","range":"(0,5 – 50) °C"}],"search_zh":"废水（含雨水与融雪水） 化学与物理检测用样品采集 手动法；自动法 范围 PN-ISO 5667-10:2021-11 | PN-77/C-04584","technique_zh":"手动法；自动法","test_object_zh":"废水（含雨水与融雪水）"},{"_id":"6a5dc9bbf1c10c8ce825ddbe","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12 /A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","categories":["water","microbiology"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825ddbf","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12 /A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 Woda, woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","categories":["water","microbiology"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825ddc0","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","methodology_en":"Most probable number of coliform bacteria","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水、生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825ddc1","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Most probable number, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825ddc2","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba Enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"水、生活饮用水 粪肠球菌数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"粪肠球菌数"},{"_id":"6a5dc9bbf1c10c8ce825ddc3","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Najbardziej prawdopodobna liczba enterokoków kałowych","methodology_en":"Most probable number of intestinal enterococci","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba enterokoków kałowych\nMetoda NPL","reference":"ENTEROLERT-DW IDEXX wydanie 06-18085-07 z roku 2019","norm_bases":["ENTEROLERT-DW IDEXX wydanie 06-18085-07 z roku 2019"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Najbardziej prawdopodobna liczba enterokoków kałowych\nMetoda NPL ENTEROLERT-DW IDEXX wydanie 06-18085-07 z roku 2019 Woda, woda do spozycia przez ludzi Najbardziej prawdopodobna liczba enterokokow kalowych\nMetoda NPL ENTEROLERT-DW IDEXX wydanie 06-18085-07 z roku 2019","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Most probable number of intestinal enterococci MPN method ENTEROLERT-DW IDEXX wydanie 06-18085-07 z roku 2019","search_zh":"水、生活饮用水 粪肠球菌最可能数 最可能数法（MPN） ENTEROLERT-DW IDEXX wydanie 06-18085-07 z roku 2019","technique_zh":"最可能数法（MPN）","test_object_zh":"水、生活饮用水","methodology_zh":"粪肠球菌最可能数"},{"_id":"6a5dc9bbf1c10c8ce825ddc4","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 22 °C","methodology_en":"Total viable count at 22 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"22 °C 微生物总数","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825ddc5","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w 36 °C","methodology_en":"Total viable count at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"36 °C 微生物总数","search_zh":"水、生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825ddc6","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825ddc7","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Clostridium perfringens łącznie z przetrwalnikami","methodology_en":"Clostridium perfringens count including spores","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda, woda do spozycia przez ludzi Liczba Clostridium perfringens lacznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016-10","search_zh":"水、生活饮用水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a5dc9bbf1c10c8ce825ddc8","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Liczba gronkowców koagulazo - dodatnich","methodology_en":"Coagulase-positive staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazo - dodatnich\nMetoda filtracji membranowej","reference":"PN-Z-11001-3:2000","norm_bases":["PN-Z-11001-3:2000"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Liczba gronkowców koagulazo - dodatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Liczba gronkowcow koagulazo - dodatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000","search_zh":"水（含游泳池水）、生活饮用水 凝固酶阳性葡萄球菌数 膜过滤法 PN-Z-11001-3:2000","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）、生活饮用水","methodology_zh":"凝固酶阳性葡萄球菌数"},{"_id":"6a5dc9bbf1c10c8ce825ddc9","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A: Procedura 5 (pożywka A-BCYE), Procedura 7 (pożywka C-GVPC)"}],"parameters_en":[{"name":"Matrix A: Procedure 5 (medium A-BCYE), Procedure 7 (medium C-GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A: Procedura 5 (pożywka A-BCYE), Procedura 7 (pożywka C-GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08 /Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A: Procedura 5 (pożywka A-BCYE), Procedura 7 (pożywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A: Procedura 5 (pozywka A-BCYE), Procedura 7 (pozywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","categories":["microbiology","water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix A: Procedure 5 (medium A-BCYE), Procedure 7 (medium C-GVPC) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","search_zh":"水（含游泳池水）、生活饮用水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","technique_zh":"膜过滤法","methodology_zh":"军团菌属细菌计数","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825ddca","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca B: Procedura 7(pożywka C-GVPC)"}],"parameters_en":[{"name":"Matrix B: Procedure 7(medium C-GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca B: Procedura 7(pożywka C-GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08 /Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca B: Procedura 7(pożywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca B: Procedura 7(pozywka C-GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","categories":["microbiology","water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix B: Procedure 7(medium C-GVPC) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","search_zh":"水（含游泳池水）、生活饮用水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","technique_zh":"膜过滤法","methodology_zh":"军团菌属细菌计数","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825ddcb","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca A Procedura 1 (pożywka A-BCYE, pożywka B-BCYE+AB)"}],"parameters_en":[{"name":"Matrix A Procedure 1 (medium A-BCYE, medium B-BCYE+AB)"}],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"technique_en":"Plate method (spread plate)","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 1 (pożywka A-BCYE, pożywka B-BCYE+AB)\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08 /Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 1 (pożywka A-BCYE, pożywka B-BCYE+AB)\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 1 (pozywka A-BCYE, pozywka B-BCYE+AB)\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","categories":["microbiology","water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Count of bacteria of the genus Legionella Plate method (spread plate) Matrix A Procedure 1 (medium A-BCYE, medium B-BCYE+AB) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","search_zh":"水（含游泳池水）、生活饮用水 军团菌属细菌计数 平板法（表面涂布） PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","technique_zh":"平板法（表面涂布）","methodology_zh":"军团菌属细菌计数","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825ddcc","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi","test_object_en":"Water (including swimming pool water), water intended for human consumption","methodology":"Liczba bakterii z rodzaju Legionella","methodology_en":"Count of bacteria of the genus Legionella","parameters":[{"name":"Matryca B: Procedura 1 (pożywka C –GVPC)"}],"parameters_en":[{"name":"Matrix B: Procedure 1 (medium C –GVPC)"}],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"technique_en":"Plate method (spread plate)","computed":[],"computed_en":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca B: Procedura 1 (pożywka C –GVPC)\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08","PN-EN ISO 11731:2017-08 /Ap1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda (w tym woda na pływalniach), woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca B: Procedura 1 (pożywka C –GVPC)\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12 Woda (w tym woda na plywalniach), woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca B: Procedura 1 (pozywka C –GVPC)\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","categories":["microbiology","water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water (including swimming pool water), water intended for human consumption Count of bacteria of the genus Legionella Plate method (spread plate) Matrix B: Procedure 1 (medium C –GVPC) PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","search_zh":"水（含游泳池水）、生活饮用水 军团菌属细菌计数 平板法（表面涂布） PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08 /Ap1:2019-12","technique_zh":"平板法（表面涂布）","methodology_zh":"军团菌属细菌计数","test_object_zh":"水（含游泳池水）、生活饮用水"},{"_id":"6a5dc9bbf1c10c8ce825ddcd","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12 /A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 Woda na plywalniach Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","categories":["water","microbiology"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"游泳池水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825ddce","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12 /A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","categories":["water","microbiology"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825ddcf","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825ddd0","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Ogólna liczba mikroorganizmów w 36 °C","methodology_en":"Total viable count at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","methodology_zh":"36 °C 微生物总数","search_zh":"游泳池水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825ddd1","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda w kąpieliskach","test_object_en":"Bathing water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12","PN-EN ISO 9308-1:2014-12 /A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda w kąpieliskach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04 Woda w kapieliskach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","categories":["water","microbiology"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Bathing water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"浴场水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12 /A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"浴场水"},{"_id":"6a5dc9bbf1c10c8ce825ddd2","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda w kąpieliskach","test_object_en":"Bathing water","methodology":"Liczba Enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda w kąpieliskach Liczba Enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda w kapieliskach Liczba Enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Bathing water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","search_zh":"浴场水 粪肠球菌数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","methodology_zh":"粪肠球菌数","test_object_zh":"浴场水"},{"_id":"6a5dc9bbf1c10c8ce825ddd3","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda w kąpieliskach","test_object_en":"Water, bathing water","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","methodology_en":"Most probable number, Escherichia coli","parameters":[],"parameters_en":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"technique_en":"MPN method","computed":[],"computed_en":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda w kąpieliskach Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-3:2002 Woda, woda w kapieliskach Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-3:2002","categories":["water","microbiology"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, bathing water Most probable number, Escherichia coli MPN method PN-EN ISO 9308-3:2002","methodology_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN）","search_zh":"大肠埃希氏菌（Escherichia coli）最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-3:2002","technique_zh":"最可能数法（MPN）"},{"_id":"6a5dc9bbf1c10c8ce825ddd4","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Osady ściekowe, odpady o) kod: 19 08 05","test_object_en":"Sewage sludge, waste o) code: 19 08 05","methodology":"Obecność bakterii z rodzaju, Salmonella","methodology_en":"Presence of bacteria of the genus, Salmonella","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność bakterii z rodzaju, Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020- 09","norm_bases":["PN-EN ISO 6579-1:2017-04","PN-EN ISO 6579-1:2017-04/A1:2020- 09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, odpady o) kod: 19 08 05 Obecność bakterii z rodzaju, Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020- 09 Osady sciekowe, odpady o) kod: 19 08 05 Obecnosc bakterii z rodzaju, Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020- 09","categories":["microbiology","water","environment"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, waste o) code: 19 08 05 Presence of bacteria of the genus, Salmonella Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020- 09","search_zh":"沙门氏菌属细菌的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/A1:2020- 09","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"沙门氏菌属细菌的检出"},{"_id":"6a5dc9bbf1c10c8ce825ddd5","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Osady ściekowe, odpady o) kod: 19 08 05","test_object_en":"Sewage sludge, waste o) code: 19 08 05","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp.","methodology_en":"Presence and count of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp.","parameters":[{"name":"Zakres","range":"od 1 ATT/kg s.m."}],"parameters_en":[{"name":"Range","range":"od 1 ATT/kg s.m."}],"technique":"Metoda flotacji, mikroskopowa","techniques":["Metoda flotacji, mikroskopowa"],"technique_en":"Flotation method, microscopic","computed":[],"computed_en":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp.\nZakres od 1 ATT/kg s.m.\nMetoda flotacji, mikroskopowa","reference":"PN-Z-19005:2018","norm_bases":["PN-Z-19005:2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe, odpady o) kod: 19 08 05 Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp.\nZakres od 1 ATT/kg s.m.\nMetoda flotacji, mikroskopowa PN-Z-19005:2018 Osady sciekowe, odpady o) kod: 19 08 05 Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp., Toxocara sp., Trichuris sp.\nZakres od 1 ATT/kg s.m.\nMetoda flotacji, mikroskopowa PN-Z-19005:2018","categories":["water","environment"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge, waste o) code: 19 08 05 Presence and count of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp. Flotation method, microscopic Range PN-Z-19005:2018","parameters_zh":[{"name":"范围","range":"od 1 ATT/kg s.m."}],"search_zh":"浮选显微镜法 范围 PN-Z-19005:2018","technique_zh":"浮选显微镜法"},{"_id":"6a5dc9bbf1c10c8ce825ddd6","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, scieki pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"水、废水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825ddd7","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda, scieki Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":34,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"水、废水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825ddd8","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Sucha pozostałość","methodology_en":"Dry residue","parameters":[{"name":"Zakres","range":"(10 – 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha pozostałość\nZakres (10 – 2000) mg/l\nMetoda wagowa","reference":"PN-78/C-04541","norm_bases":["PN-78/C-04541"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Sucha pozostałość\nZakres (10 – 2000) mg/l\nMetoda wagowa PN-78/C-04541 Woda, scieki Sucha pozostalosc\nZakres (10 – 2000) mg/l\nMetoda wagowa PN-78/C-04541","categories":["water"],"row_index":35,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dry residue Gravimetric method Range PN-78/C-04541","parameters_zh":[{"name":"范围","range":"(10 – 2000) mg/l"}],"search_zh":"水、废水 干残渣 重量法 范围 PN-78/C-04541","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"干残渣"},{"_id":"6a5dc9bbf1c10c8ce825ddd9","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie substancji rozpuszczonych","methodology_en":"Dissolved solids concentration","parameters":[{"name":"Zakres","range":"(10 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 1000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji rozpuszczonych\nZakres (10 – 1000) mg/l\nMetoda wagowa","reference":"PN-EN 15216:2022-03","norm_bases":["PN-EN 15216:2022-03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie substancji rozpuszczonych\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-EN 15216:2022-03 Woda, scieki Stezenie substancji rozpuszczonych\nZakres (10 – 1000) mg/l\nMetoda wagowa PN-EN 15216:2022-03","categories":["water"],"row_index":36,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dissolved solids concentration Gravimetric method Range PN-EN 15216:2022-03","parameters_zh":[{"name":"范围","range":"(10 – 1000) mg/l"}],"search_zh":"水、废水 溶解性物质浓度 重量法 范围 PN-EN 15216:2022-03","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"溶解性物质浓度"},{"_id":"6a5dc9bbf1c10c8ce825ddda","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 – 1000) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chlorków\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, scieki Stezenie chlorkow\nZakres (5,0 – 1000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":37,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1000) mg/l"}],"search_zh":"水、废水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825dddb","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie siarczanów (VI)","methodology_en":"Sulphate (VI) concentration","parameters":[{"name":"Zakres","range":"(10 – 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów (VI)\nZakres (10 – 500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie siarczanów (VI)\nZakres (10 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda, scieki Stezenie siarczanow (VI)\nZakres (10 – 500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":38,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sulphate (VI) concentration Gravimetric method Range PN-ISO 9280:2002","parameters_zh":[{"name":"范围","range":"(10 – 500) mg/l"}],"search_zh":"水、废水 硫酸盐(VI)浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"水、废水","methodology_zh":"硫酸盐(VI)浓度"},{"_id":"6a5dc9bbf1c10c8ce825dddc","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,50 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,50 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,50 – 250) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu Kjeldahla\nZakres (0,50 – 250) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda, scieki Stezenie azotu Kjeldahla\nZakres (0,50 – 250) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":39,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,50 – 250) mg/l"}],"search_zh":"水、废水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825dddd","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 15,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 15,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5814:2013-04E","norm_bases":["PN-EN ISO 5814:2013-04E"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04E Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5814:2013-04E","categories":["water"],"row_index":40,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dissolved oxygen concentration Electrochemical method Range PN-EN ISO 5814:2013-04E","parameters_zh":[{"name":"范围","range":"(0,5 – 15,0) mg/l O2"}],"search_zh":"水、废水 溶解氧浓度 电化学法 范围 PN-EN ISO 5814:2013-04E","technique_zh":"电化学法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9bbf1c10c8ce825ddde","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu amonowego","methodology_en":"Ammonium nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,20 – 250) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie azotu amonowego\nZakres (0,20 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu amonowego\nZakres (0,20 – 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Woda, scieki Stezenie azotu amonowego\nZakres (0,20 – 250) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":41,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,20 – 250) mg/l"}],"search_zh":"水、废水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825dddf","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotanowego","methodology_en":"Nitrate nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,050 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotanowego\nZakres (0,050 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576/08","norm_bases":["PN-82/C-04576/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotanowego\nZakres (0,050 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08 Woda, scieki Stezenie azotu azotanowego\nZakres (0,050 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576/08","categories":["water"],"row_index":42,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576/08","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,050 – 100) mg/l"}],"search_zh":"水、废水 硝态氮浓度 分光光度法 范围 PN-82/C-04576/08","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825dde0","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu azotynowego","methodology_en":"Nitrite nitrogen concentration","parameters":[{"name":"Zakres","range":"(0,007 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,007 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotu azotynowego\nZakres (0,007 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu azotynowego\nZakres (0,007 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, scieki Stezenie azotu azotynowego\nZakres (0,007 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":43,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,007 – 2,0) mg/l"}],"search_zh":"水、废水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825dde1","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie azotu ogólnego (z obliczeń)","methodology_en":"Total nitrogen concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PN-73/C-04576/14","norm_bases":["PN-73/C-04576/14"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie azotu ogólnego (z obliczeń) PN-73/C-04576/14 Woda, scieki Stezenie azotu ogolnego (z obliczen) PN-73/C-04576/14","categories":["water"],"row_index":44,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total nitrogen concentration (calculated) PN-73/C-04576/14","methodology_zh":"总氮浓度（计算值）","search_zh":"水、废水 总氮浓度（计算值） PN-73/C-04576/14","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825dde2","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie metali","methodology_en":"Metal concentrations","parameters":[{"name":"cynk","range":"(0,10 – 4,0) mg/l"}],"parameters_en":[{"name":"zinc","range":"(0,10 – 4,0) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie metali\ncynk (0,10 – 4,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN ISO 8288:2002 metoda A","norm_bases":["PN ISO 8288:2002 metoda A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie metali\ncynk (0,10 – 4,0) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN ISO 8288:2002 metoda A Woda, scieki Stezenie metali\ncynk (0,10 – 4,0) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN ISO 8288:2002 metoda A","categories":["water","materials"],"row_index":45,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Metal concentrations Flame atomic absorption spectrometry (FAAS) zinc PN ISO 8288:2002 metoda A","methodology_zh":"金属浓度","parameters_zh":[{"name":"锌","range":"(0,10 – 4,0) mg/l"}],"search_zh":"水、废水 金属浓度 火焰原子吸收光谱法（FAAS） 锌 PN ISO 8288:2002 metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825dde3","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Chemiczne Zapotrzebowanie Tlenu","methodology_en":"Chemical Oxygen Demand","parameters":[{"name":"ChZT-Cr"},{"name":"Zakres","range":"(10 – 9000) mg/l O2"}],"parameters_en":[{"name":"COD-Cr"},{"name":"Range","range":"(10 – 9000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Chemiczne Zapotrzebowanie Tlenu\nZakres:\nChZT-Cr\nZakres (10 – 9000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Chemiczne Zapotrzebowanie Tlenu\nZakres:\nChZT-Cr\nZakres (10 – 9000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda, scieki Chemiczne Zapotrzebowanie Tlenu\nZakres:\nChZT-Cr\nZakres (10 – 9000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":46,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chemical Oxygen Demand Spectrophotometric method COD-Cr Range PN-ISO 15705:2005","parameters_zh":[{"name":"化学需氧量（COD-Cr）"},{"name":"范围","range":"(10 – 9000) mg/l O2"}],"search_zh":"水、废水 分光光度法 化学需氧量（COD-Cr） 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825dde4","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie tlenu rozpuszczonego","methodology_en":"Dissolved oxygen concentration","parameters":[{"name":"Zakres","range":"(0,5 – 15,0) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,5 – 15,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN 25813:1997","norm_bases":["PN-EN 25813:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2\nMetoda miareczkowa PN-EN 25813:1997 Woda, scieki Stezenie tlenu rozpuszczonego\nZakres (0,5 – 15,0) mg/l O2\nMetoda miareczkowa PN-EN 25813:1997","categories":["water"],"row_index":47,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Dissolved oxygen concentration Titrimetric method Range PN-EN 25813:1997","parameters_zh":[{"name":"范围","range":"(0,5 – 15,0) mg/l O2"}],"search_zh":"水、废水 溶解氧浓度 滴定法 范围 PN-EN 25813:1997","technique_zh":"滴定法","test_object_zh":"水、废水","methodology_zh":"溶解氧浓度"},{"_id":"6a5dc9bbf1c10c8ce825dde5","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Indeks oleju mineralnego","methodology_en":"Mineral oil index","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Indeks oleju mineralnego\nZakres (0,10 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Woda, scieki Indeks oleju mineralnego\nZakres (0,10 – 50) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":48,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"}],"search_zh":"水、废水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"水、废水","methodology_zh":"矿物油指数"},{"_id":"6a5dc9bbf1c10c8ce825dde6","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Indeks fenolowy","methodology_en":"Phenol index","parameters":[{"name":"Zakres","range":"(0,005 – 0,10) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,005 – 0,10) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Indeks fenolowy\nZakres (0,005 – 0,10) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 metoda B","norm_bases":["PN-ISO 6439:1994 metoda B"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Indeks fenolowy\nZakres (0,005 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B Woda, scieki Indeks fenolowy\nZakres (0,005 – 0,10) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B","categories":["water"],"row_index":49,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994 metoda B","parameters_zh":[{"name":"范围","range":"(0,005 – 0,10) mg/l"}],"search_zh":"水、废水 酚指数 分光光度法 范围 PN-ISO 6439:1994 metoda B","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"酚指数"},{"_id":"6a5dc9bbf1c10c8ce825dde7","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(0,010 – 20,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 – 20,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,010 – 20,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016","norm_bases":["PN-ISO 6332:2001+Ap1:2016"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie żelaza ogólnego\nZakres (0,010 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016 Woda, scieki Stezenie zelaza ogolnego\nZakres (0,010 – 20,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016","categories":["water"],"row_index":50,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 20,0) mg/l"}],"search_zh":"水、废水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825dde8","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"nikiel","range":"(6,0 – 6000) μg/l"},{"name":"miedź","range":"(3,0 – 2000) μg/l"},{"name":"ołów","range":"(3,0 – 2500) μg/l"},{"name":"kadm","range":"(0,40 – 400) μg/l"},{"name":"chrom og.","range":"(2,0 – 2000) μg/l"},{"name":"arsen","range":"(3,0 – 2500) μg/l"}],"parameters_en":[{"name":"nickel","range":"(6,0 – 6000) μg/l"},{"name":"copper","range":"(3,0 – 2000) μg/l"},{"name":"lead","range":"(3,0 – 2500) μg/l"},{"name":"cadmium","range":"(0,40 – 400) μg/l"},{"name":"total chromium","range":"(2,0 – 2000) μg/l"},{"name":"arsenic","range":"(3,0 – 2500) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrochemiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrochemiczną (ETAAS)"],"technique_en":"Atomic absorption spectrometry with electrochemical atomization (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nnikiel (6,0 – 6000) μg/l\nmiedź (3,0 – 2000) μg/l\nołów (3,0 – 2500) μg/l\nkadm (0,40 – 400) μg/l\nchrom og. (2,0 – 2000) μg/l\narsen (3,0 – 2500) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrochemiczną (ETAAS)","reference":"PN-EN-ISO 15586:2005","norm_bases":["PN-EN-ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie pierwiastków\nZakres:\nnikiel (6,0 – 6000) μg/l\nmiedź (3,0 – 2000) μg/l\nołów (3,0 – 2500) μg/l\nkadm (0,40 – 400) μg/l\nchrom og. (2,0 – 2000) μg/l\narsen (3,0 – 2500) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrochemiczną (ETAAS) PN-EN-ISO 15586:2005 Woda, scieki Stezenie pierwiastkow\nZakres:\nnikiel (6,0 – 6000) μg/l\nmiedz (3,0 – 2000) μg/l\nolow (3,0 – 2500) μg/l\nkadm (0,40 – 400) μg/l\nchrom og. (2,0 – 2000) μg/l\narsen (3,0 – 2500) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrochemiczna (ETAAS) PN-EN-ISO 15586:2005","categories":["water","materials"],"row_index":51,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Element concentration Atomic absorption spectrometry with electrochemical atomization (ETAAS) nickel copper lead cadmium total chromium arsenic PN-EN-ISO 15586:2005","methodology_zh":"元素浓度","parameters_zh":[{"name":"镍","range":"(6,0 – 6000) μg/l"},{"name":"铜","range":"(3,0 – 2000) μg/l"},{"name":"铅","range":"(3,0 – 2500) μg/l"},{"name":"镉","range":"(0,40 – 400) μg/l"},{"name":"chrom og.","range":"(2,0 – 2000) μg/l"},{"name":"砷","range":"(3,0 – 2500) μg/l"}],"search_zh":"水、废水 元素浓度 电热原子化原子吸收光谱法（ETAAS） 镍 铜 铅 镉 砷 PN-EN-ISO 15586:2005","test_object_zh":"水、废水","technique_zh":"电热原子化原子吸收光谱法（ETAAS）"},{"_id":"6a5dc9bbf1c10c8ce825dde9","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"bromki","range":"(0,5 – 30) mg/l"},{"name":"chlorki","range":"(1,0 – 2 500) mg/l"},{"name":"siarczany","range":"(2,0 – 2 500) mg/l"},{"name":"azotany","range":"(0,10 – 100) mg/l"},{"name":"fluorki","range":"(0,10 – 10) mg/l"}],"parameters_en":[{"name":"bromides","range":"(0,5 – 30) mg/l"},{"name":"chlorides","range":"(1,0 – 2 500) mg/l"},{"name":"sulfates","range":"(2,0 – 2 500) mg/l"},{"name":"nitrates","range":"(0,10 – 100) mg/l"},{"name":"fluorides","range":"(0,10 – 10) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC–CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC–CD)"],"technique_en":"Ion chromatography with conductometric detection (IC–CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nZakres:\nbromki (0,5 – 30) mg/l\nchlorki (1,0 – 2 500) mg/l\nsiarczany (2,0 – 2 500) mg/l\nazotany (0,10 – 100) mg/l\nfluorki (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC–CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie anionów\nZakres:\nbromki (0,5 – 30) mg/l\nchlorki (1,0 – 2 500) mg/l\nsiarczany (2,0 – 2 500) mg/l\nazotany (0,10 – 100) mg/l\nfluorki (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC–CD) PN-EN ISO 10304-1:2009 +AC:2012 Woda, scieki Stezenie anionow\nZakres:\nbromki (0,5 – 30) mg/l\nchlorki (1,0 – 2 500) mg/l\nsiarczany (2,0 – 2 500) mg/l\nazotany (0,10 – 100) mg/l\nfluorki (0,10 – 10) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC–CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":52,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Anion concentrations Ion chromatography with conductometric detection (IC–CD) bromides chlorides sulfates nitrates fluorides PN-EN ISO 10304-1:2009 +AC:2012","methodology_zh":"阴离子浓度","search_zh":"水、废水 阴离子浓度 溴化物 氯化物 硫酸盐 硝酸盐 氟化物 PN-EN ISO 10304-1:2009 +AC:2012","test_object_zh":"水、废水","parameters_zh":[{"name":"溴化物","range":"(0,5 – 30) mg/l"},{"name":"氯化物","range":"(1,0 – 2 500) mg/l"},{"name":"硫酸盐","range":"(2,0 – 2 500) mg/l"},{"name":"硝酸盐","range":"(0,10 – 100) mg/l"},{"name":"氟化物","range":"(0,10 – 10) mg/l"}]},{"_id":"6a5dc9bbf1c10c8ce825ddea","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(1 – 6000) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(1 – 6000) mg/l O2"}],"technique":"Metoda elektrochemiczna; Metoda optyczna","techniques":["Metoda elektrochemiczna","Metoda optyczna"],"technique_en":"Electrochemical method; Optical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna; Metoda optyczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna; Metoda optyczna PN-EN ISO 5815-1:2019-12 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (1 – 6000) mg/l O2\nMetoda elektrochemiczna; Metoda optyczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":53,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method; Optical method BOD5 Range PN-EN ISO 5815-1:2019-12","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(1 – 6000) mg/l O2"}],"search_zh":"水、废水 生化需氧量 BZT5（BOD5） 范围 PN-EN ISO 5815-1:2019-12","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825ddeb","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Biochemiczne zapotrzebowanie tlenu","methodology_en":"Biochemical oxygen demand","parameters":[{"name":"BZT5"},{"name":"Zakres","range":"(0,60 – 7,0) mg/l O2"}],"parameters_en":[{"name":"BOD5"},{"name":"Range","range":"(0,60 – 7,0) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"technique_en":"Electrochemical method","computed":[],"computed_en":[],"activity":"Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,60 – 7,0) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN 1899-2:2002","norm_bases":["PN-EN 1899-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,60 – 7,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002 Woda, scieki Biochemiczne zapotrzebowanie tlenu\nZakres:\nBZT5\nZakres (0,60 – 7,0) mg/l O2\nMetoda elektrochemiczna PN-EN 1899-2:2002","categories":["water"],"row_index":54,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Biochemical oxygen demand Electrochemical method BOD5 Range PN-EN 1899-2:2002","methodology_zh":"生化需氧量","parameters_zh":[{"name":"BZT5（BOD5）"},{"name":"范围","range":"(0,60 – 7,0) mg/l O2"}],"search_zh":"水、废水 生化需氧量 电化学法 BZT5（BOD5） 范围 PN-EN 1899-2:2002","technique_zh":"电化学法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825ddec","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie ortofosforanów","methodology_en":"Orthophosphate concentration","parameters":[{"name":"Zakres","range":"(0,040 – 50,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,040 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ortofosforanów\nZakres (0,040 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 p.4","norm_bases":["PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 p.4"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie ortofosforanów\nZakres (0,040 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 p.4 Woda, scieki Stezenie ortofosforanow\nZakres (0,040 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 p.4","categories":["water"],"row_index":55,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 p.4","parameters_zh":[{"name":"范围","range":"(0,040 – 50,0) mg/l"}],"search_zh":"水、废水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 p.4","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a5dc9bbf1c10c8ce825dded","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie fosforu ogólnego","methodology_en":"Total phosphorus concentration","parameters":[{"name":"Zakres","range":"(0,040 – 50,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,040 – 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,040 – 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie fosforu ogólnego\nZakres (0,040 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010 Woda, scieki Stezenie fosforu ogolnego\nZakres (0,040 – 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","categories":["water"],"row_index":56,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 50,0) mg/l"}],"search_zh":"水、废水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006+Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825ddee","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie sodu","methodology_en":"Sodium concentration","parameters":[{"name":"Zakres","range":"(5,0 – 500) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 500) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"technique_en":"Flame atomic absorption spectrometry (FAAS)","computed":[],"computed_en":[],"activity":"Stężenie sodu\nZakres (5,0 – 500) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 9964-1:1994+Ap1:2009 | PN-ISO 9964-1/Ak:1997","norm_bases":["PN-ISO 9964-1:1994+Ap1:2009","PN-ISO 9964-1/Ak:1997"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie sodu\nZakres (5,0 – 500) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+Ap1:2009 | PN-ISO 9964-1/Ak:1997 Woda, scieki Stezenie sodu\nZakres (5,0 – 500) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 9964-1:1994+Ap1:2009 | PN-ISO 9964-1/Ak:1997","categories":["water"],"row_index":57,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Sodium concentration Flame atomic absorption spectrometry (FAAS) Range PN-ISO 9964-1:1994+Ap1:2009 | PN-ISO 9964-1/Ak:1997","parameters_zh":[{"name":"范围","range":"(5,0 – 500) mg/l"}],"search_zh":"水、废水 钠浓度 火焰原子吸收光谱法（FAAS） 范围 PN-ISO 9964-1:1994+Ap1:2009 | PN-ISO 9964-1/Ak:1997","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水、废水","methodology_zh":"钠浓度"},{"_id":"6a5dc9bbf1c10c8ce825ddef","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie cyjanków wolnych","methodology_en":"Free cyanide concentration","parameters":[{"name":"Zakres","range":"(0,03 – 0,6) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,03 – 0,6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie cyjanków wolnych\nZakres (0,03 – 0,6) mg/l\nMetoda spektrofotometryczna","reference":"Test HACH nr LCK 315 edycja 2 z 08/2025","norm_bases":["Test HACH nr LCK 315 edycja 2 z 08/2025"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie cyjanków wolnych\nZakres (0,03 – 0,6) mg/l\nMetoda spektrofotometryczna Test HACH nr LCK 315 edycja 2 z 08/2025 Woda, scieki Stezenie cyjankow wolnych\nZakres (0,03 – 0,6) mg/l\nMetoda spektrofotometryczna Test HACH nr LCK 315 edycja 2 z 08/2025","categories":["water"],"row_index":58,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Free cyanide concentration Spectrophotometric method Range Test HACH nr LCK 315 edycja 2 z 08/2025","parameters_zh":[{"name":"范围","range":"(0,03 – 0,6) mg/l"}],"search_zh":"水、废水 游离氰化物浓度 分光光度法 范围 Test HACH nr LCK 315 edycja 2 z 08/2025","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"游离氰化物浓度"},{"_id":"6a5dc9bbf1c10c8ce825ddf0","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(25 – 3000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(25 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (25 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Przewodność elektryczna właściwa\nZakres (25 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, scieki Przewodnosc elektryczna wlasciwa\nZakres (25 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":59,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(25 – 3000) μS/cm"}],"search_zh":"水、废水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825ddf1","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chloru wolnego","methodology_en":"Free chlorine concentration","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda, scieki Stezenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":60,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Free chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"水、废水 游离氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825ddf2","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chloru ogólnego","methodology_en":"Total chlorine concentration","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru ogólnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chloru ogólnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda, scieki Stezenie chloru ogolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":61,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Total chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"水、废水 总氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"水、废水","methodology_zh":"总氯浓度"},{"_id":"6a5dc9bbf1c10c8ce825ddf3","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chloru związanego (z obliczeń)","methodology_en":"Combined chlorine concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chloru związanego (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda, scieki Stezenie chloru zwiazanego (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":62,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Combined chlorine concentration (calculated) PN-EN ISO 7393-2:2018-04","search_zh":"水、废水 化合氯浓度（计算值） PN-EN ISO 7393-2:2018-04","test_object_zh":"水、废水","methodology_zh":"化合氯浓度（计算值）"},{"_id":"6a5dc9bbf1c10c8ce825ddf4","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie chloramin (z obliczeń)","methodology_en":"Chloramine concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloramin (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie chloramin (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda, scieki Stezenie chloramin (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":63,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Chloramine concentration (calculated) PN-EN ISO 7393-2:2018-04","search_zh":"水、废水 氯胺浓度（由计算得出） PN-EN ISO 7393-2:2018-04","test_object_zh":"水、废水","methodology_zh":"氯胺浓度（由计算得出）"},{"_id":"6a5dc9bbf1c10c8ce825ddf5","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, ścieki","test_object_en":"Water, wastewater","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"Nikiel","range":"(0,0020 – 2,0) mg/l"},{"name":"Miedź","range":"(0,050 – 2,0) mg/l"},{"name":"Ołów","range":"(0,0010 – 2,5) mg/l"},{"name":"Kadm","range":"(0,0005 – 1,0) mg/l"},{"name":"Chrom","range":"(0,010 – 2,0) mg/l"},{"name":"Arsen","range":"(0,010 – 2,5) mg/l"},{"name":"Mangan","range":"(0,0050 – 2,0) mg/l"},{"name":"Żelazo","range":"(0,010 – 20) mg/l"},{"name":"Cynk","range":"(0,100 - 10,0) mg/l"},{"name":"Bor","range":"(0,100 – 15,0) mg/l"},{"name":"Glin","range":"(0,010 – 4,0) mg/l"},{"name":"Cyna","range":"(0,020 – 4,0) mg/l"},{"name":"Antymon","range":"(0,050 – 1,0) mg/l"},{"name":"Bar","range":"(0,0010 - 4,0) mg/l"},{"name":"Molibden","range":"(0,030 - 2,0) mg/l"},{"name":"Rtęć","range":"(0,005 – 0,250) mg/l"},{"name":"Selen","range":"( 0,010 – 2,0) mg/l"},{"name":"Srebro","range":"(0,0010 – 1,0) mg/l"},{"name":"Wanad","range":"(0,050 - 4,0) mg/l"},{"name":"Tytan","range":"(0,050 - 2,0) mg/l"},{"name":"Beryl","range":"(0,100 – 2,0) mg/l"},{"name":"Kobalt","range":"(0,050 - 2,0) mg/l"},{"name":"Magnez","range":"(1,0 – 200) mg/l"},{"name":"Wapń","range":"(1,0 – 200) mg/l"},{"name":"Sód","range":"(1,0 – 200) mg/l"},{"name":"Potas","range":"(1,0 – 200) mg/l"},{"name":"Fosfor","range":"(0,010 – 50,0) mg/l"},{"name":"Twardość ogólna (z obliczeń)"}],"parameters_en":[{"name":"Nickel","range":"(0,0020 – 2,0) mg/l"},{"name":"Copper","range":"(0,050 – 2,0) mg/l"},{"name":"Lead","range":"(0,0010 – 2,5) mg/l"},{"name":"Cadmium","range":"(0,0005 – 1,0) mg/l"},{"name":"Chromium","range":"(0,010 – 2,0) mg/l"},{"name":"Arsenic","range":"(0,010 – 2,5) mg/l"},{"name":"Manganese","range":"(0,0050 – 2,0) mg/l"},{"name":"Iron","range":"(0,010 – 20) mg/l"},{"name":"Zinc","range":"(0,100 - 10,0) mg/l"},{"name":"Boron","range":"(0,100 – 15,0) mg/l"},{"name":"Aluminium","range":"(0,010 – 4,0) mg/l"},{"name":"Tin","range":"(0,020 – 4,0) mg/l"},{"name":"Antimony","range":"(0,050 – 1,0) mg/l"},{"name":"Barium","range":"(0,0010 - 4,0) mg/l"},{"name":"Molybdenum","range":"(0,030 - 2,0) mg/l"},{"name":"Mercury","range":"(0,005 – 0,250) mg/l"},{"name":"Selenium","range":"( 0,010 – 2,0) mg/l"},{"name":"Silver","range":"(0,0010 – 1,0) mg/l"},{"name":"Vanadium","range":"(0,050 - 4,0) mg/l"},{"name":"Titanium","range":"(0,050 - 2,0) mg/l"},{"name":"Beryllium","range":"(0,100 – 2,0) mg/l"},{"name":"Cobalt","range":"(0,050 - 2,0) mg/l"},{"name":"Magnesium","range":"(1,0 – 200) mg/l"},{"name":"Calcium","range":"(1,0 – 200) mg/l"},{"name":"Sodium","range":"(1,0 – 200) mg/l"},{"name":"Potassium","range":"(1,0 – 200) mg/l"},{"name":"Phosphorus","range":"(0,010 – 50,0) mg/l"},{"name":"Total hardness (calculated)"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nNikiel (0,0020 – 2,0) mg/l\nMiedź (0,050 – 2,0) mg/l\nOłów (0,0010 – 2,5) mg/l\nKadm (0,0005 – 1,0) mg/l\nChrom (0,010 – 2,0) mg/l\nArsen (0,010 – 2,5) mg/l\nMangan (0,0050 – 2,0) mg/l\nŻelazo (0,010 – 20) mg/l\nCynk (0,100 - 10,0) mg/l\nBor (0,100 – 15,0) mg/l\nGlin (0,010 – 4,0) mg/l\nCyna (0,020 – 4,0) mg/l\nAntymon (0,050 – 1,0) mg/l\nBar (0,0010 - 4,0) mg/l\nMolibden (0,030 - 2,0) mg/l\nRtęć (0,005 – 0,250) mg/l\nSelen ( 0,010 – 2,0) mg/l\nSrebro (0,0010 – 1,0) mg/l\nWanad (0,050 - 4,0) mg/l\nTytan (0,050 - 2,0) mg/l\nBeryl (0,100 – 2,0) mg/l\nKobalt (0,050 - 2,0) mg/l\nMagnez (1,0 – 200) mg/l\nWapń (1,0 – 200) mg/l\nSód (1,0 – 200) mg/l\nPotas (1,0 – 200) mg/l\nFosfor (0,010 – 50,0) mg/l\nTwardość ogólna (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, ścieki Stężenie pierwiastków\nZakres:\nNikiel (0,0020 – 2,0) mg/l\nMiedź (0,050 – 2,0) mg/l\nOłów (0,0010 – 2,5) mg/l\nKadm (0,0005 – 1,0) mg/l\nChrom (0,010 – 2,0) mg/l\nArsen (0,010 – 2,5) mg/l\nMangan (0,0050 – 2,0) mg/l\nŻelazo (0,010 – 20) mg/l\nCynk (0,100 - 10,0) mg/l\nBor (0,100 – 15,0) mg/l\nGlin (0,010 – 4,0) mg/l\nCyna (0,020 – 4,0) mg/l\nAntymon (0,050 – 1,0) mg/l\nBar (0,0010 - 4,0) mg/l\nMolibden (0,030 - 2,0) mg/l\nRtęć (0,005 – 0,250) mg/l\nSelen ( 0,010 – 2,0) mg/l\nSrebro (0,0010 – 1,0) mg/l\nWanad (0,050 - 4,0) mg/l\nTytan (0,050 - 2,0) mg/l\nBeryl (0,100 – 2,0) mg/l\nKobalt (0,050 - 2,0) mg/l\nMagnez (1,0 – 200) mg/l\nWapń (1,0 – 200) mg/l\nSód (1,0 – 200) mg/l\nPotas (1,0 – 200) mg/l\nFosfor (0,010 – 50,0) mg/l\nTwardość ogólna (z obliczeń)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda, scieki Stezenie pierwiastkow\nZakres:\nNikiel (0,0020 – 2,0) mg/l\nMiedz (0,050 – 2,0) mg/l\nOlow (0,0010 – 2,5) mg/l\nKadm (0,0005 – 1,0) mg/l\nChrom (0,010 – 2,0) mg/l\nArsen (0,010 – 2,5) mg/l\nMangan (0,0050 – 2,0) mg/l\nZelazo (0,010 – 20) mg/l\nCynk (0,100 - 10,0) mg/l\nBor (0,100 – 15,0) mg/l\nGlin (0,010 – 4,0) mg/l\nCyna (0,020 – 4,0) mg/l\nAntymon (0,050 – 1,0) mg/l\nBar (0,0010 - 4,0) mg/l\nMolibden (0,030 - 2,0) mg/l\nRtec (0,005 – 0,250) mg/l\nSelen ( 0,010 – 2,0) mg/l\nSrebro (0,0010 – 1,0) mg/l\nWanad (0,050 - 4,0) mg/l\nTytan (0,050 - 2,0) mg/l\nBeryl (0,100 – 2,0) mg/l\nKobalt (0,050 - 2,0) mg/l\nMagnez (1,0 – 200) mg/l\nWapn (1,0 – 200) mg/l\nSod (1,0 – 200) mg/l\nPotas (1,0 – 200) mg/l\nFosfor (0,010 – 50,0) mg/l\nTwardosc ogolna (z obliczen)\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["water","materials"],"row_index":64,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, wastewater Element concentration Inductively coupled plasma optical emission spectrometry (ICP-OES) Nickel Copper Lead Cadmium Chromium Arsenic Manganese Iron Zinc Boron Aluminium Tin Antimony Barium Molybdenum Mercury Selenium Silver Vanadium Titanium Beryllium Cobalt Magnesium Calcium Sodium Potassium Phosphorus Total hardness (calculated) PN-EN ISO 11885:2009","methodology_zh":"元素浓度","parameters_zh":[{"name":"镍","range":"(0,0020 – 2,0) mg/l"},{"name":"铜","range":"(0,050 – 2,0) mg/l"},{"name":"铅","range":"(0,0010 – 2,5) mg/l"},{"name":"镉","range":"(0,0005 – 1,0) mg/l"},{"name":"铬","range":"(0,010 – 2,0) mg/l"},{"name":"砷","range":"(0,010 – 2,5) mg/l"},{"name":"锰","range":"(0,0050 – 2,0) mg/l"},{"name":"铁","range":"(0,010 – 20) mg/l"},{"name":"锌","range":"(0,100 - 10,0) mg/l"},{"name":"硼","range":"(0,100 – 15,0) mg/l"},{"name":"铝","range":"(0,010 – 4,0) mg/l"},{"name":"锡","range":"(0,020 – 4,0) mg/l"},{"name":"锑","range":"(0,050 – 1,0) mg/l"},{"name":"钡","range":"(0,0010 - 4,0) mg/l"},{"name":"钼","range":"(0,030 - 2,0) mg/l"},{"name":"汞","range":"(0,005 – 0,250) mg/l"},{"name":"硒","range":"( 0,010 – 2,0) mg/l"},{"name":"银","range":"(0,0010 – 1,0) mg/l"},{"name":"钒","range":"(0,050 - 4,0) mg/l"},{"name":"钛","range":"(0,050 - 2,0) mg/l"},{"name":"铍","range":"(0,100 – 2,0) mg/l"},{"name":"钴","range":"(0,050 - 2,0) mg/l"},{"name":"镁","range":"(1,0 – 200) mg/l"},{"name":"钙","range":"(1,0 – 200) mg/l"},{"name":"钠","range":"(1,0 – 200) mg/l"},{"name":"钾","range":"(1,0 – 200) mg/l"},{"name":"磷","range":"(0,010 – 50,0) mg/l"},{"name":"总硬度（由计算得出）"}],"search_zh":"水、废水 元素浓度 电感耦合等离子体原子发射光谱法（ICP-OES） 镍 铜 铅 镉 铬 砷 锰 铁 锌 硼 铝 锡 锑 钡 钼 汞 硒 银 钒 钛 铍 钴 镁 钙 钠 钾 磷 总硬度（由计算得出） PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水、废水"},{"_id":"6a5dc9bbf1c10c8ce825ddf6","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie pierwiastków","methodology_en":"Element concentration","parameters":[{"name":"Rtęć","range":"(0,40 – 10,0) μg/l"},{"name":"Arsen","range":"(1,0 – 15,0) μg/l"},{"name":"Antymon","range":"(1,0 – 15,0) μg/l"},{"name":"Selen","range":"(1,0 – 15,0) μg/l"}],"parameters_en":[{"name":"Mercury","range":"(0,40 – 10,0) μg/l"},{"name":"Arsenic","range":"(1,0 – 15,0) μg/l"},{"name":"Antimony","range":"(1,0 – 15,0) μg/l"},{"name":"Selenium","range":"(1,0 – 15,0) μg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","computed":[],"computed_en":[],"activity":"Stężenie pierwiastków\nZakres:\nRtęć (0,40 – 10,0) μg/l\nArsen (1,0 – 15,0) μg/l\nAntymon (1,0 – 15,0) μg/l\nSelen (1,0 – 15,0) μg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie pierwiastków\nZakres:\nRtęć (0,40 – 10,0) μg/l\nArsen (1,0 – 15,0) μg/l\nAntymon (1,0 – 15,0) μg/l\nSelen (1,0 – 15,0) μg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 Woda, woda do spozycia przez ludzi Stezenie pierwiastkow\nZakres:\nRtec (0,40 – 10,0) μg/l\nArsen (1,0 – 15,0) μg/l\nAntymon (1,0 – 15,0) μg/l\nSelen (1,0 – 15,0) μg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009","categories":["water"],"row_index":65,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Element concentration Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) Mercury Arsenic Antimony Selenium PN-EN ISO 11885:2009","methodology_zh":"元素浓度","search_zh":"水、生活饮用水 元素浓度 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） 汞 砷 锑 硒 PN-EN ISO 11885:2009","test_object_zh":"水、生活饮用水","parameters_zh":[{"name":"汞","range":"(0,40 – 10,0) μg/l"},{"name":"砷","range":"(1,0 – 15,0) μg/l"},{"name":"锑","range":"(1,0 – 15,0) μg/l"},{"name":"硒","range":"(1,0 – 15,0) μg/l"}],"technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）"},{"_id":"6a5dc9bbf1c10c8ce825ddf7","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie ogólnego węgla organicznego","methodology_en":"Total organic carbon concentration","parameters":[{"name":"Zakres","range":"(2,0 – 30,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 30,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (2,0 – 30,0) mg/l\nMetoda spektrofotometryczna","reference":"Test Nanocolor OWO 30 NEO nr 985048 wydanie 12.2024","norm_bases":["Test Nanocolor OWO 30 NEO nr 985048 wydanie 12.2024"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie ogólnego węgla organicznego\nZakres (2,0 – 30,0) mg/l\nMetoda spektrofotometryczna Test Nanocolor OWO 30 NEO nr 985048 wydanie 12.2024 Woda, woda do spozycia przez ludzi Stezenie ogolnego wegla organicznego\nZakres (2,0 – 30,0) mg/l\nMetoda spektrofotometryczna Test Nanocolor OWO 30 NEO nr 985048 wydanie 12.2024","categories":["water"],"row_index":66,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total organic carbon concentration Spectrophotometric method Range Test Nanocolor OWO 30 NEO nr 985048 wydanie 12.2024","parameters_zh":[{"name":"范围","range":"(2,0 – 30,0) mg/l"}],"search_zh":"水、生活饮用水 总有机碳浓度 分光光度法 范围 Test Nanocolor OWO 30 NEO nr 985048 wydanie 12.2024","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"总有机碳浓度"},{"_id":"6a5dc9bbf1c10c8ce825ddf8","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","test_object_en":"Rainwater and snowmelt water","methodology":"Zawiesiny ogólne","methodology_en":"Total suspended solids (TSS)","parameters":[{"name":"Zakres","range":"(2,0 – 2000) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe i roztopowe Zawiesiny ogólne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Wody opadowe i roztopowe Zawiesiny ogolne\nZakres (2,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":67,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(2,0 – 2000) mg/l"}],"search_zh":"雨水与融雪水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"雨水与融雪水"},{"_id":"6a5dc9bbf1c10c8ce825ddf9","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","test_object_en":"Rainwater and snowmelt water","methodology":"Indeks oleju mineralnego","methodology_en":"Mineral oil index","parameters":[{"name":"Zakres","range":"(0,10 – 50) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,10 – 50) mg/l"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"technique_en":"Gas chromatography with flame ionization detection (GC-FID)","computed":[],"computed_en":[],"activity":"Indeks oleju mineralnego\nZakres (0,10 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-EN ISO 9377-2:2003","norm_bases":["PN-EN ISO 9377-2:2003"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Wody opadowe i roztopowe Indeks oleju mineralnego\nZakres (0,10 – 50) mg/l\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-EN ISO 9377-2:2003 Wody opadowe i roztopowe Indeks oleju mineralnego\nZakres (0,10 – 50) mg/l\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-EN ISO 9377-2:2003","categories":["water","petro"],"row_index":68,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Rainwater and snowmelt water Mineral oil index Gas chromatography with flame ionization detection (GC-FID) Range PN-EN ISO 9377-2:2003","parameters_zh":[{"name":"范围","range":"(0,10 – 50) mg/l"}],"search_zh":"雨水与融雪水 矿物油指数 气相色谱-氢火焰离子化检测法（GC-FID） 范围 PN-EN ISO 9377-2:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","methodology_zh":"矿物油指数","test_object_zh":"雨水与融雪水"},{"_id":"6a5dc9bbf1c10c8ce825ddfa","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie surfaktantów anionowych.","methodology_en":"Anionic surfactant concentration.","parameters":[{"name":"Zakres","range":"(0,050 – 20) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,050 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie surfaktantów anionowych.\nZakres (0,050 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie surfaktantów anionowych.\nZakres (0,050 – 20) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Scieki Stezenie surfaktantow anionowych.\nZakres (0,050 – 20) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":69,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Anionic surfactant concentration. Spectrophotometric method Range PN-EN 903:2002","parameters_zh":[{"name":"范围","range":"(0,050 – 20) mg/l"}],"search_zh":"污水 分光光度法 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825ddfb","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie substancji ekstrahujących się eterem naftowym.","methodology_en":"Concentration of substances extractable with petroleum ether.","parameters":[{"name":"Zakres","range":"(10 – 200) mg/l"}],"parameters_en":[{"name":"Range","range":"(10 – 200) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Stężenie substancji ekstrahujących się eterem naftowym.\nZakres (10 – 200) mg/l\nMetoda wagowa","reference":"PS-3 edycja 4 z dnia 22.02.2013 r.","norm_bases":["PS-3 edycja 4 z dnia 22.02.2013 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie substancji ekstrahujących się eterem naftowym.\nZakres (10 – 200) mg/l\nMetoda wagowa PS-3 edycja 4 z dnia 22.02.2013 r. Scieki Stezenie substancji ekstrahujacych sie eterem naftowym.\nZakres (10 – 200) mg/l\nMetoda wagowa PS-3 edycja 4 z dnia 22.02.2013 r.","categories":["water"],"row_index":70,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Concentration of substances extractable with petroleum ether. Gravimetric method Range PS-3 edycja 4 z dnia 22.02.2013 r.","parameters_zh":[{"name":"范围","range":"(10 – 200) mg/l"}],"search_zh":"污水 重量法 范围 PS-3 edycja 4 z dnia 22.02.2013 r.","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a5dc9bbf1c10c8ce825ddfc","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie chromu (VI)","methodology_en":"Chromium(VI) concentration","parameters":[{"name":"Zakres","range":"(0,010 – 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chromu (VI)\nZakres (0,010 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604/08","norm_bases":["PN-77/C-04604/08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie chromu (VI)\nZakres (0,010 – 1,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08 Scieki Stezenie chromu (VI)\nZakres (0,010 – 1,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08","categories":["water"],"row_index":71,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Chromium(VI) concentration Spectrophotometric method Range PN-77/C-04604/08","parameters_zh":[{"name":"范围","range":"(0,010 – 1,0) mg/l"}],"search_zh":"污水 六价铬浓度 分光光度法 范围 PN-77/C-04604/08","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"六价铬浓度"},{"_id":"6a5dc9bbf1c10c8ce825ddfd","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Ścieki","test_object_en":"Wastewater","methodology":"Stężenie surfaktantów niejonowych","methodology_en":"Non-ionic surfactant concentration","parameters":[{"name":"Zakres","range":"(0,20-100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,20-100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie surfaktantów niejonowych\nZakres (0,20-100) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7875-2:2002","norm_bases":["PN-ISO 7875-2:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Ścieki Stężenie surfaktantów niejonowych\nZakres (0,20-100) mg/l\nMetoda spektrofotometryczna PN-ISO 7875-2:2002 Scieki Stezenie surfaktantow niejonowych\nZakres (0,20-100) mg/l\nMetoda spektrofotometryczna PN-ISO 7875-2:2002","categories":["water"],"row_index":72,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Wastewater Non-ionic surfactant concentration Spectrophotometric method Range PN-ISO 7875-2:2002","parameters_zh":[{"name":"范围","range":"(0,20-100) mg/l"}],"search_zh":"污水 非离子表面活性剂浓度 分光光度法 范围 PN-ISO 7875-2:2002","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"非离子表面活性剂浓度"},{"_id":"6a5dc9bbf1c10c8ce825ddfe","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":73,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825ddff","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-99/C-04554/04 załącznik A","norm_bases":["PN-99/C-04554/04 załącznik A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie magnezu (z obliczeń) PN-99/C-04554/04 załącznik A Woda Stezenie magnezu (z obliczen) PN-99/C-04554/04 zalacznik A","categories":["water"],"row_index":74,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Magnesium concentration (calculated) PN-99/C-04554/04 załącznik A","search_zh":"水 镁浓度（计算值） PN-99/C-04554/04 załącznik A","test_object_zh":"水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5dc9bbf1c10c8ce825de00","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(7 – 1000) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(7 – 1000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (7 – 1000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (7 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (7 – 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":75,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(7 – 1000) mg/l CaCO3"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825de01","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Zasadowość ogólna","methodology_en":"Total alkalinity","parameters":[{"name":"Zakres","range":"(0,40 – 20) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,40 – 20) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zasadowość ogólna\nZakres (0,40 – 20) mmol/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Zasadowość ogólna\nZakres (0,40 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004 Woda Zasadowosc ogolna\nZakres (0,40 – 20) mmol/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":76,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001+Ap1:2004","parameters_zh":[{"name":"范围","range":"(0,40 – 20) mmol/l"}],"search_zh":"水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001+Ap1:2004","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"总碱度"},{"_id":"6a5dc9bbf1c10c8ce825de02","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie wodorowęglanów (z obliczeń)","methodology_en":"Bicarbonate concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie wodorowęglanów (z obliczeń)","reference":"PN-EN ISO 9963-1:2001+Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie wodorowęglanów (z obliczeń) PN-EN ISO 9963-1:2001+Ap1:2004 Woda Stezenie wodoroweglanow (z obliczen) PN-EN ISO 9963-1:2001+Ap1:2004","categories":["water"],"row_index":77,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Bicarbonate concentration (calculated) PN-EN ISO 9963-1:2001+Ap1:2004","search_zh":"水 碳酸氢盐浓度（由计算得出） PN-EN ISO 9963-1:2001+Ap1:2004","test_object_zh":"水","methodology_zh":"碳酸氢盐浓度（由计算得出）"},{"_id":"6a5dc9bbf1c10c8ce825de03","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Twardość węglanowa, Twardość niewęglanowa (z obliczeń)","methodology_en":"Carbonate hardness, Non-carbonate hardness (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Twardość węglanowa, Twardość niewęglanowa (z obliczeń)","reference":"PN-EN ISO 9963-1:2001+Ap1:2004 | PN-ISO 6059:1999","norm_bases":["PN-EN ISO 9963-1:2001+Ap1:2004","PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Twardość węglanowa, Twardość niewęglanowa (z obliczeń) PN-EN ISO 9963-1:2001+Ap1:2004 | PN-ISO 6059:1999 Woda Twardosc weglanowa, Twardosc nieweglanowa (z obliczen) PN-EN ISO 9963-1:2001+Ap1:2004 | PN-ISO 6059:1999","categories":["water"],"row_index":78,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Carbonate hardness, Non-carbonate hardness (calculated) PN-EN ISO 9963-1:2001+Ap1:2004 | PN-ISO 6059:1999","search_zh":"水 碳酸盐硬度、非碳酸盐硬度（由计算得出） PN-EN ISO 9963-1:2001+Ap1:2004 | PN-ISO 6059:1999","test_object_zh":"水","methodology_zh":"碳酸盐硬度、非碳酸盐硬度（由计算得出）"},{"_id":"6a5dc9bbf1c10c8ce825de04","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chromu (VI)","methodology_en":"Chromium(VI) concentration","parameters":[{"name":"Zakres","range":"(0,005 – 0,050) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,005 – 0,050) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chromu (VI)\nZakres (0,005 – 0,050) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 18412:2007","norm_bases":["PN-EN ISO 18412:2007"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chromu (VI)\nZakres (0,005 – 0,050) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007 Woda Stezenie chromu (VI)\nZakres (0,005 – 0,050) mg/l\nMetoda spektrofotometryczna PN-EN ISO 18412:2007","categories":["water"],"row_index":79,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chromium(VI) concentration Spectrophotometric method Range PN-EN ISO 18412:2007","parameters_zh":[{"name":"范围","range":"(0,005 – 0,050) mg/l"}],"search_zh":"水 六价铬浓度 分光光度法 范围 PN-EN ISO 18412:2007","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"六价铬浓度"},{"_id":"6a5dc9bbf1c10c8ce825de05","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie glinu","methodology_en":"Aluminium concentration","parameters":[{"name":"Zakres","range":"(0,040 – 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,040 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie glinu\nZakres (0,040 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04605/02","norm_bases":["PN-92/C-04605/02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie glinu\nZakres (0,040 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04605/02 Woda Stezenie glinu\nZakres (0,040 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04605/02","categories":["water"],"row_index":80,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Aluminium concentration Spectrophotometric method Range PN-92/C-04605/02","parameters_zh":[{"name":"范围","range":"(0,040 – 1,0) mg/l"}],"search_zh":"水 铝浓度 分光光度法 范围 PN-92/C-04605/02","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"铝浓度"},{"_id":"6a5dc9bbf1c10c8ce825de06","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie boru","methodology_en":"Boron concentration","parameters":[{"name":"Zakres","range":"(0,50 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,50 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie boru\nZakres (0,50 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-75/C-04563.01","norm_bases":["PN-75/C-04563.01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie boru\nZakres (0,50 – 2,0) mg/l\nMetoda spektrofotometryczna PN-75/C-04563.01 Woda Stezenie boru\nZakres (0,50 – 2,0) mg/l\nMetoda spektrofotometryczna PN-75/C-04563.01","categories":["water"],"row_index":81,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Boron concentration Spectrophotometric method Range PN-75/C-04563.01","parameters_zh":[{"name":"范围","range":"(0,50 – 2,0) mg/l"}],"search_zh":"水 硼浓度 分光光度法 范围 PN-75/C-04563.01","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"硼浓度"},{"_id":"6a5dc9bbf1c10c8ce825de07","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,50 – 10) mg /l O2"}],"parameters_en":[{"name":"Range","range":"(0,50 – 10) mg /l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10) mg /l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Indeks nadmanganianowy\nZakres (0,50 – 10) mg /l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda Indeks nadmanganianowy\nZakres (0,50 – 10) mg /l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":82,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10) mg /l O2"}],"search_zh":"水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825de08","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,030 – 2,6) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,030 – 2,6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres (0,030 – 2,6) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie jonu amonowego\nZakres (0,030 – 2,6) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Stezenie jonu amonowego\nZakres (0,030 – 2,6) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":83,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,030 – 2,6) mg/l"}],"search_zh":"水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825de09","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Obecność obcego smaku","methodology_en":"Presence of foreign taste","parameters":[{"name":"Liczba progowa smaku TFN"},{"name":"Zakres","range":"1 – 4"}],"parameters_en":[{"name":"Taste threshold number TFN"},{"name":"Range","range":"1 – 4"}],"technique":"Metoda jakościowa; Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda jakościowa","Metoda uproszczona, parzysta, wybór niewymuszony"],"technique_en":"Qualitative method; Simplified paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Obecność obcego smaku\nZakres:\nLiczba progowa smaku TFN\nZakres 1 – 4\nMetoda jakościowa; Metoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Obecność obcego smaku\nZakres:\nLiczba progowa smaku TFN\nZakres 1 – 4\nMetoda jakościowa; Metoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda Obecnosc obcego smaku\nZakres:\nLiczba progowa smaku TFN\nZakres 1 – 4\nMetoda jakosciowa; Metoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":84,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Presence of foreign taste Qualitative method; Simplified paired method, non-forced choice Taste threshold number TFN Range PN-EN 1622:2006","parameters_zh":[{"name":"味阈值 TFN"},{"name":"范围","range":"1 – 4"}],"search_zh":"水 异味（口感）的检出 定性法；简化法、成对法、非强制选择 味阈值 TFN 范围 PN-EN 1622:2006","test_object_zh":"水","methodology_zh":"异味（口感）的检出","technique_zh":"定性法；简化法、成对法、非强制选择"},{"_id":"6a5dc9bbf1c10c8ce825de0a","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Obecność obcego zapachu","methodology_en":"Presence of foreign odour","parameters":[{"name":"Liczba progowa zapachu TON"},{"name":"Zakres","range":"1 – 4"}],"parameters_en":[{"name":"Odour threshold number TON"},{"name":"Range","range":"1 – 4"}],"technique":"Metoda jakościowa; Metoda uproszczona, parzysta, wybór niewymuszony","techniques":["Metoda jakościowa","Metoda uproszczona, parzysta, wybór niewymuszony"],"technique_en":"Qualitative method; Simplified paired method, non-forced choice","computed":[],"computed_en":[],"activity":"Obecność obcego zapachu\nZakres:\nLiczba progowa zapachu TON\nZakres 1 – 4\nMetoda jakościowa; Metoda uproszczona, parzysta, wybór niewymuszony","reference":"PN-EN 1622:2006","norm_bases":["PN-EN 1622:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Obecność obcego zapachu\nZakres:\nLiczba progowa zapachu TON\nZakres 1 – 4\nMetoda jakościowa; Metoda uproszczona, parzysta, wybór niewymuszony PN-EN 1622:2006 Woda Obecnosc obcego zapachu\nZakres:\nLiczba progowa zapachu TON\nZakres 1 – 4\nMetoda jakosciowa; Metoda uproszczona, parzysta, wybor niewymuszony PN-EN 1622:2006","categories":["water"],"row_index":85,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Presence of foreign odour Qualitative method; Simplified paired method, non-forced choice Odour threshold number TON Range PN-EN 1622:2006","parameters_zh":[{"name":"嗅阈值 TON"},{"name":"范围","range":"1 – 4"}],"search_zh":"水 异味的检出 定性法；简化法、成对法、非强制选择 嗅阈值 TON 范围 PN-EN 1622:2006","test_object_zh":"水","methodology_zh":"异味的检出","technique_zh":"定性法；简化法、成对法、非强制选择"},{"_id":"6a5dc9bbf1c10c8ce825de0b","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(1,5 – 2000) μg/l"}],"parameters_en":[{"name":"Range","range":"(1,5 – 2000) μg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrochemiczną (ETAAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrochemiczną (ETAAS)"],"technique_en":"Atomic absorption spectrometry with electrochemical atomization (ETAAS)","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (1,5 – 2000) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrochemiczną (ETAAS)","reference":"PN-EN-ISO 15586:2005","norm_bases":["PN-EN-ISO 15586:2005"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie manganu\nZakres (1,5 – 2000) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrochemiczną (ETAAS) PN-EN-ISO 15586:2005 Woda Stezenie manganu\nZakres (1,5 – 2000) μg/l\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrochemiczna (ETAAS) PN-EN-ISO 15586:2005","categories":["water"],"row_index":86,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Manganese concentration Atomic absorption spectrometry with electrochemical atomization (ETAAS) Range PN-EN-ISO 15586:2005","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(1,5 – 2000) μg/l"}],"search_zh":"水 锰浓度 电热原子化原子吸收光谱法（ETAAS） 范围 PN-EN-ISO 15586:2005","test_object_zh":"水","technique_zh":"电热原子化原子吸收光谱法（ETAAS）"},{"_id":"6a5dc9bbf1c10c8ce825de0c","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(2,0 – 70) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(2,0 – 70) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (2,0 – 70) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012+Ap1:2015 metoda C","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015 metoda C"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Barwa\nZakres (2,0 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015 metoda C Woda Barwa\nZakres (2,0 – 70) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012+Ap1:2015 metoda C","categories":["water"],"row_index":87,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Colour Spectrophotometric method Range PN-EN ISO 7887:2012+Ap1:2015 metoda C","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2,0 – 70) mg/l Pt"}],"search_zh":"水 色度 分光光度法 范围 PN-EN ISO 7887:2012+Ap1:2015 metoda C","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825de0d","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(0,05 – 2,5) mmol/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 2,5) mmol/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (0,05 – 2,5) mmol/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie wapnia\nZakres (0,05 – 2,5) mmol/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda Stezenie wapnia\nZakres (0,05 – 2,5) mmol/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":88,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Calcium concentration Titrimetric method Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(0,05 – 2,5) mmol/l"}],"search_zh":"水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"钙浓度"},{"_id":"6a5dc9bbf1c10c8ce825de0e","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie pestycydów:","methodology_en":"Pesticide concentrations:","parameters":[{"name":"aldryna"},{"name":"dieldryna"},{"name":"heptachlor"},{"name":"Zakres","range":"(0,01-1,0) μg/l"},{"name":"p, p’- DDD"},{"name":"p, p’- DDE"},{"name":"p, p’- DDT"},{"name":"endryna"},{"name":"alfa- HCH"},{"name":"beta- HCH"},{"name":"delta- HCH"},{"name":"gamma- HCH"},{"name":"alfa-endosulfan"},{"name":"beta-endosulfan"},{"name":"epoksyd-heptachloru"},{"name":"aldehyd endryny"},{"name":"metoksychlor"},{"name":"Zakres","range":"(0,020-1,0) μg/l"},{"name":"Suma stężeń pestycydów (z obliczeń)"}],"parameters_en":[{"name":"aldrin"},{"name":"dieldrin"},{"name":"heptachlor"},{"name":"Range","range":"(0,01-1,0) μg/l"},{"name":"p, p’- DDD"},{"name":"p, p’- DDE"},{"name":"p, p’- DDT"},{"name":"endrin"},{"name":"alpha- HCH"},{"name":"beta- HCH"},{"name":"delta- HCH"},{"name":"gamma- HCH"},{"name":"alpha-endosulfan"},{"name":"beta-endosulfan"},{"name":"heptachlor epoxide"},{"name":"endrin aldehyde"},{"name":"methoxychlor"},{"name":"Range","range":"(0,020-1,0) μg/l"},{"name":"Sum of pesticide concentrations (calculated)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie pestycydów:\nZakres:\naldryna\ndieldryna\nheptachlor\nZakres (0,01-1,0) μg/l\np, p’- DDD\np, p’- DDE\np, p’- DDT\nendryna\nalfa- HCH\nbeta- HCH\ndelta- HCH\ngamma- HCH\nalfa-endosulfan\nbeta-endosulfan\nepoksyd-heptachloru\naldehyd endryny\nmetoksychlor\nZakres (0,020-1,0) μg/l\nSuma stężeń pestycydów (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie pestycydów:\nZakres:\naldryna\ndieldryna\nheptachlor\nZakres (0,01-1,0) μg/l\np, p’- DDD\np, p’- DDE\np, p’- DDT\nendryna\nalfa- HCH\nbeta- HCH\ndelta- HCH\ngamma- HCH\nalfa-endosulfan\nbeta-endosulfan\nepoksyd-heptachloru\naldehyd endryny\nmetoksychlor\nZakres (0,020-1,0) μg/l\nSuma stężeń pestycydów (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda Stezenie pestycydow:\nZakres:\naldryna\ndieldryna\nheptachlor\nZakres (0,01-1,0) μg/l\np, p’- DDD\np, p’- DDE\np, p’- DDT\nendryna\nalfa- HCH\nbeta- HCH\ndelta- HCH\ngamma- HCH\nalfa-endosulfan\nbeta-endosulfan\nepoksyd-heptachloru\naldehyd endryny\nmetoksychlor\nZakres (0,020-1,0) μg/l\nSuma stezen pestycydow (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":89,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Pesticide concentrations: Gas chromatography with electron capture detection (GC-ECD) aldrin dieldrin heptachlor Range p, p’- DDD p, p’- DDE p, p’- DDT endrin alpha- HCH beta- HCH delta- HCH gamma- HCH alpha-endosulfan beta-endosulfan heptachlor epoxide endrin aldehyde methoxychlor Range Sum of pesticide concentrations (calculated) PN-EN ISO 6468:2002","parameters_zh":[{"name":"艾氏剂"},{"name":"狄氏剂"},{"name":"七氯"},{"name":"范围","range":"(0,01-1,0) μg/l"},{"name":"p, p’- DDD"},{"name":"p, p’- DDE"},{"name":"p, p’- DDT"},{"name":"异狄氏剂"},{"name":"alfa- HCH"},{"name":"beta- HCH"},{"name":"delta- HCH"},{"name":"gamma- HCH"},{"name":"alfa-endosulfan"},{"name":"beta-endosulfan"},{"name":"epoksyd-heptachloru"},{"name":"异狄氏剂醛"},{"name":"甲氧滴滴涕"},{"name":"范围","range":"(0,020-1,0) μg/l"},{"name":"Suma stężeń pestycydów (z obliczeń)"}],"search_zh":"水 气相色谱-电子捕获检测法（GC-ECD） 艾氏剂 狄氏剂 七氯 范围 异狄氏剂 异狄氏剂醛 甲氧滴滴涕 范围 PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水"},{"_id":"6a5dc9bbf1c10c8ce825de0f","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie trihalometanów (THM)","methodology_en":"Trihalomethanes (THM) concentration","parameters":[{"name":"trichlorometan (chloroform)"},{"name":"Zakres","range":"(1,5 – 100) μg/l"},{"name":"bromodichlorometan","range":"(1,5– 100) μg/l"},{"name":"dibromochlorometan","range":"(1,5 – 100) μg/l"},{"name":"tribromometan (bromoform)","range":"(1,5 – 100) μg/l"},{"name":"Suma stężeń trihalometanów (THM) (z obliczeń)"}],"parameters_en":[{"name":"trichloromethane (chloroform)"},{"name":"Range","range":"(1,5 – 100) μg/l"},{"name":"bromodichloromethane","range":"(1,5– 100) μg/l"},{"name":"dibromochloromethane","range":"(1,5 – 100) μg/l"},{"name":"tribromomethane (bromoform)","range":"(1,5 – 100) μg/l"},{"name":"Sum of trihalomethane (THM) concentrations (calculated)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie trihalometanów (THM)\nZakres:\ntrichlorometan (chloroform)\nZakres (1,5 – 100) μg/l\nbromodichlorometan (1,5– 100) μg/l\ndibromochlorometan (1,5 – 100) μg/l\ntribromometan (bromoform) (1,5 – 100) μg/l\nSuma stężeń trihalometanów (THM) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie trihalometanów (THM)\nZakres:\ntrichlorometan (chloroform)\nZakres (1,5 – 100) μg/l\nbromodichlorometan (1,5– 100) μg/l\ndibromochlorometan (1,5 – 100) μg/l\ntribromometan (bromoform) (1,5 – 100) μg/l\nSuma stężeń trihalometanów (THM) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 Woda Stezenie trihalometanow (THM)\nZakres:\ntrichlorometan (chloroform)\nZakres (1,5 – 100) μg/l\nbromodichlorometan (1,5– 100) μg/l\ndibromochlorometan (1,5 – 100) μg/l\ntribromometan (bromoform) (1,5 – 100) μg/l\nSuma stezen trihalometanow (THM) (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":90,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Trihalomethanes (THM) concentration Gas chromatography with electron capture detection (GC-ECD) trichloromethane (chloroform) Range bromodichloromethane dibromochloromethane tribromomethane (bromoform) Sum of trihalomethane (THM) concentrations (calculated) PN-EN ISO 10301:2002","parameters_zh":[{"name":"三氯甲烷（氯仿）"},{"name":"范围","range":"(1,5 – 100) μg/l"},{"name":"一溴二氯甲烷","range":"(1,5– 100) μg/l"},{"name":"二溴一氯甲烷","range":"(1,5 – 100) μg/l"},{"name":"三溴甲烷（溴仿）","range":"(1,5 – 100) μg/l"},{"name":"Suma stężeń trihalometanów (THM) (z obliczeń)"}],"search_zh":"水 三卤甲烷（THM）浓度 气相色谱-电子捕获检测法（GC-ECD） 三氯甲烷（氯仿） 范围 一溴二氯甲烷 二溴一氯甲烷 三溴甲烷（溴仿） PN-EN ISO 10301:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水","methodology_zh":"三卤甲烷（THM）浓度"},{"_id":"6a5dc9bbf1c10c8ce825de10","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda","test_object_en":"Water","methodology":"Stężenie chloranów, chlorynów","methodology_en":"Chlorate, chlorite concentration","parameters":[{"name":"Zakres","range":"(0,10 – 2,0) mg/l"},{"name":"Suma chloranów, chlorynów (z obliczeń)"}],"parameters_en":[{"name":"Range","range":"(0,10 – 2,0) mg/l"},{"name":"Sum of chlorates, chlorites (calculated)"}],"technique":"Metodą chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metodą chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"By ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie chloranów, chlorynów\nZakres:\nZakres (0,10 – 2,0) mg/l\nSuma chloranów, chlorynów (z obliczeń)\nMetodą chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda Stężenie chloranów, chlorynów\nZakres:\nZakres (0,10 – 2,0) mg/l\nSuma chloranów, chlorynów (z obliczeń)\nMetodą chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda Stezenie chloranow, chlorynow\nZakres:\nZakres (0,10 – 2,0) mg/l\nSuma chloranow, chlorynow (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":91,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water Chlorate, chlorite concentration By ion chromatography with conductometric detection (IC-CD) Range Sum of chlorates, chlorites (calculated) PN-EN ISO 10304-4:2022-08","parameters_zh":[{"name":"范围","range":"(0,10 – 2,0) mg/l"},{"name":"Suma chloranów, chlorynów (z obliczeń)"}],"search_zh":"水 氯酸盐、亚氯酸盐浓度 范围 PN-EN ISO 10304-4:2022-08","test_object_zh":"水","methodology_zh":"氯酸盐、亚氯酸盐浓度"},{"_id":"6a5dc9bbf1c10c8ce825de11","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie chloru wolnego","methodology_en":"Free chlorine concentration","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda na plywalniach Stezenie chloru wolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":92,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Free chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"游泳池水 游离氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825de12","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie chloru ogólnego","methodology_en":"Total chlorine concentration","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru ogólnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie chloru ogólnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04 Woda na plywalniach Stezenie chloru ogolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":93,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Total chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2018-04","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"游泳池水 总氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2018-04","technique_zh":"分光光度法","test_object_zh":"游泳池水","methodology_zh":"总氯浓度"},{"_id":"6a5dc9bbf1c10c8ce825de13","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie chloru związanego (z obliczeń)","methodology_en":"Combined chlorine concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PN-EN ISO 7393-2:2018-04","norm_bases":["PN-EN ISO 7393-2:2018-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie chloru związanego (z obliczeń) PN-EN ISO 7393-2:2018-04 Woda na plywalniach Stezenie chloru zwiazanego (z obliczen) PN-EN ISO 7393-2:2018-04","categories":["water"],"row_index":94,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Combined chlorine concentration (calculated) PN-EN ISO 7393-2:2018-04","search_zh":"游泳池水 化合氯浓度（计算值） PN-EN ISO 7393-2:2018-04","test_object_zh":"游泳池水","methodology_zh":"化合氯浓度（计算值）"},{"_id":"6a5dc9bbf1c10c8ce825de14","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,50 – 10) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,50 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda na plywalniach Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":95,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10) mg/l O2"}],"search_zh":"游泳池水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825de15","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie anionów","methodology_en":"Anion concentrations","parameters":[{"name":"azotany","range":"(0,10 – 100) mg/l"}],"parameters_en":[{"name":"nitrates","range":"(0,10 – 100) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"technique_en":"Ion chromatography with conductometric detection (IC-CD)","computed":[],"computed_en":[],"activity":"Stężenie anionów\nazotany (0,10 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie anionów\nazotany (0,10 – 100) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009+AC:2012 Woda na plywalniach Stezenie anionow\nazotany (0,10 – 100) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009+AC:2012","categories":["water"],"row_index":96,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Anion concentrations Ion chromatography with conductometric detection (IC-CD) nitrates PN-EN ISO 10304-1:2009+AC:2012","methodology_zh":"阴离子浓度","search_zh":"游泳池水 阴离子浓度 离子色谱-电导检测法（IC-CD） 硝酸盐 PN-EN ISO 10304-1:2009+AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"游泳池水","parameters_zh":[{"name":"硝酸盐","range":"(0,10 – 100) mg/l"}]},{"_id":"6a5dc9bbf1c10c8ce825de16","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,10 – 100) NTU"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Mętność\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda na plywalniach Metnosc\nZakres (0,10 – 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":97,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 100) NTU"}],"search_zh":"游泳池水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825de17","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie glinu","methodology_en":"Aluminium concentration","parameters":[{"name":"Zakres","range":"(0,040 – 1,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,040 – 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie glinu\nZakres (0,040 – 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04605/02","norm_bases":["PN-92/C-04605/02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie glinu\nZakres (0,040 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04605/02 Woda na plywalniach Stezenie glinu\nZakres (0,040 – 1,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04605/02","categories":["water"],"row_index":98,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Aluminium concentration Spectrophotometric method Range PN-92/C-04605/02","parameters_zh":[{"name":"范围","range":"(0,040 – 1,0) mg/l"}],"search_zh":"游泳池水 铝浓度 分光光度法 范围 PN-92/C-04605/02","technique_zh":"分光光度法","test_object_zh":"游泳池水","methodology_zh":"铝浓度"},{"_id":"6a5dc9bbf1c10c8ce825de18","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda na plywalniach pH\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":99,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"游泳池水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825de19","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Potencjał utleniająco-redukujący + (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl","methodology_en":"Oxidation-reduction potential + (redox) ref. to Ag/AgCl 3,5 mol/l KCl","parameters":[{"name":"Zakres","range":"(220 – 1000) mV"}],"parameters_en":[{"name":"Range","range":"(220 – 1000) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"Potencjał utleniająco-redukujący + (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (220 – 1000) mV\nMetoda potencjometryczna","reference":"PS-16 edycja 1 z dnia 05.07.2016 r.","norm_bases":["PS-16 edycja 1 z dnia 05.07.2016 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Potencjał utleniająco-redukujący + (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (220 – 1000) mV\nMetoda potencjometryczna PS-16 edycja 1 z dnia 05.07.2016 r. Woda na plywalniach Potencjal utleniajaco-redukujacy + (redoks) wzgl. Ag/AgCl 3,5 mol/l KCl\nZakres (220 – 1000) mV\nMetoda potencjometryczna PS-16 edycja 1 z dnia 05.07.2016 r.","categories":["water"],"row_index":100,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Oxidation-reduction potential + (redox) ref. to Ag/AgCl 3,5 mol/l KCl Potentiometric method Range PS-16 edycja 1 z dnia 05.07.2016 r.","parameters_zh":[{"name":"范围","range":"(220 – 1000) mV"}],"search_zh":"游泳池水 电位法 范围 PS-16 edycja 1 z dnia 05.07.2016 r.","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a5dc9bbf1c10c8ce825de1a","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie trihalometanów (THM)","methodology_en":"Trihalomethanes (THM) concentration","parameters":[{"name":"trichlorometan (chloroform)"},{"name":"Zakres","range":"(1,5 – 100) μg/l"},{"name":"bromodichlorometan","range":"(1,5– 100) μg/l"},{"name":"dibromochlorometan","range":"(1,5 – 100) μg/l"},{"name":"tribromometan (bromoform)","range":"(1,5 – 100) μg/l"},{"name":"Suma stężeń trihalometanów (THM) (z obliczeń)"}],"parameters_en":[{"name":"trichloromethane (chloroform)"},{"name":"Range","range":"(1,5 – 100) μg/l"},{"name":"bromodichloromethane","range":"(1,5– 100) μg/l"},{"name":"dibromochloromethane","range":"(1,5 – 100) μg/l"},{"name":"tribromomethane (bromoform)","range":"(1,5 – 100) μg/l"},{"name":"Sum of trihalomethane (THM) concentrations (calculated)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"technique_en":"Gas chromatography with electron capture detection (GC-ECD)","computed":[],"computed_en":[],"activity":"Stężenie trihalometanów (THM)\nZakres:\ntrichlorometan (chloroform)\nZakres (1,5 – 100) μg/l\nbromodichlorometan (1,5– 100) μg/l\ndibromochlorometan (1,5 – 100) μg/l\ntribromometan (bromoform) (1,5 – 100) μg/l\nSuma stężeń trihalometanów (THM) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie trihalometanów (THM)\nZakres:\ntrichlorometan (chloroform)\nZakres (1,5 – 100) μg/l\nbromodichlorometan (1,5– 100) μg/l\ndibromochlorometan (1,5 – 100) μg/l\ntribromometan (bromoform) (1,5 – 100) μg/l\nSuma stężeń trihalometanów (THM) (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 Woda na plywalniach Stezenie trihalometanow (THM)\nZakres:\ntrichlorometan (chloroform)\nZakres (1,5 – 100) μg/l\nbromodichlorometan (1,5– 100) μg/l\ndibromochlorometan (1,5 – 100) μg/l\ntribromometan (bromoform) (1,5 – 100) μg/l\nSuma stezen trihalometanow (THM) (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":101,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Trihalomethanes (THM) concentration Gas chromatography with electron capture detection (GC-ECD) trichloromethane (chloroform) Range bromodichloromethane dibromochloromethane tribromomethane (bromoform) Sum of trihalomethane (THM) concentrations (calculated) PN-EN ISO 10301:2002","parameters_zh":[{"name":"三氯甲烷（氯仿）"},{"name":"范围","range":"(1,5 – 100) μg/l"},{"name":"一溴二氯甲烷","range":"(1,5– 100) μg/l"},{"name":"二溴一氯甲烷","range":"(1,5 – 100) μg/l"},{"name":"三溴甲烷（溴仿）","range":"(1,5 – 100) μg/l"},{"name":"Suma stężeń trihalometanów (THM) (z obliczeń)"}],"search_zh":"游泳池水 三卤甲烷（THM）浓度 气相色谱-电子捕获检测法（GC-ECD） 三氯甲烷（氯仿） 范围 一溴二氯甲烷 二溴一氯甲烷 三溴甲烷（溴仿） PN-EN ISO 10301:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"游泳池水","methodology_zh":"三卤甲烷（THM）浓度"},{"_id":"6a5dc9bbf1c10c8ce825de1b","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"pH - w KCl, pH - w CaCl2, pH - w H2O","methodology_en":"pH - in KCl, pH - in CaCl2, pH - in H2O","parameters":[{"name":"Zakres","range":"2,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"2,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH - w KCl, pH - w CaCl2, pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba pH - w KCl, pH - w CaCl2, pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Gleba pH - w KCl, pH - w CaCl2, pH - w H2O\nZakres 2,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":102,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil pH - in KCl, pH - in CaCl2, pH - in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","parameters_zh":[{"name":"范围","range":"2,0 – 12,0"}],"search_zh":"土壤 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"土壤"},{"_id":"6a5dc9bbf1c10c8ce825de1c","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość pierwiastków","methodology_en":"Element content","parameters":[{"name":"Chrom","range":"(1,0 – 5000) mg/kg"},{"name":"Cynk","range":"(10 – 10000) mg/kg"},{"name":"Ołów","range":"(0,1 – 5000) mg/kg"},{"name":"Kadm","range":"(0,05 – 50) mg/kg"},{"name":"Nikiel","range":"(0,2 – 5000) mg/kg"},{"name":"Miedź","range":"(5,0 – 5000) mg/kg"},{"name":"Rtęć","range":"(0,5 – 50) mg/kg"}],"parameters_en":[{"name":"Chromium","range":"(1,0 – 5000) mg/kg"},{"name":"Zinc","range":"(10 – 10000) mg/kg"},{"name":"Lead","range":"(0,1 – 5000) mg/kg"},{"name":"Cadmium","range":"(0,05 – 50) mg/kg"},{"name":"Nickel","range":"(0,2 – 5000) mg/kg"},{"name":"Copper","range":"(5,0 – 5000) mg/kg"},{"name":"Mercury","range":"(0,5 – 50) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków\nZakres:\nChrom (1,0 – 5000) mg/kg\nCynk (10 – 10000) mg/kg\nOłów (0,1 – 5000) mg/kg\nKadm (0,05 – 50) mg/kg\nNikiel (0,2 – 5000) mg/kg\nMiedź (5,0 – 5000) mg/kg\nRtęć (0,5 – 50) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN 16170:2017-02","norm_bases":["PN-EN 16170:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość pierwiastków\nZakres:\nChrom (1,0 – 5000) mg/kg\nCynk (10 – 10000) mg/kg\nOłów (0,1 – 5000) mg/kg\nKadm (0,05 – 50) mg/kg\nNikiel (0,2 – 5000) mg/kg\nMiedź (5,0 – 5000) mg/kg\nRtęć (0,5 – 50) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN 16170:2017-02 Gleba Zawartosc pierwiastkow\nZakres:\nChrom (1,0 – 5000) mg/kg\nCynk (10 – 10000) mg/kg\nOlow (0,1 – 5000) mg/kg\nKadm (0,05 – 50) mg/kg\nNikiel (0,2 – 5000) mg/kg\nMiedz (5,0 – 5000) mg/kg\nRtec (0,5 – 50) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN 16170:2017-02","categories":["materials","environment"],"row_index":103,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Element content Inductively coupled plasma optical emission spectrometry (ICP-OES) Chromium Zinc Lead Cadmium Nickel Copper Mercury PN-EN 16170:2017-02","methodology_zh":"元素含量","parameters_zh":[{"name":"铬","range":"(1,0 – 5000) mg/kg"},{"name":"锌","range":"(10 – 10000) mg/kg"},{"name":"铅","range":"(0,1 – 5000) mg/kg"},{"name":"镉","range":"(0,05 – 50) mg/kg"},{"name":"镍","range":"(0,2 – 5000) mg/kg"},{"name":"铜","range":"(5,0 – 5000) mg/kg"},{"name":"汞","range":"(0,5 – 50) mg/kg"}],"search_zh":"土壤 元素含量 电感耦合等离子体原子发射光谱法（ICP-OES） 铬 锌 铅 镉 镍 铜 汞 PN-EN 16170:2017-02","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"土壤"},{"_id":"6a5dc9bbf1c10c8ce825de1d","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Gleba","test_object_en":"Soil","methodology":"Zawartość fosforu przyswajalnego","methodology_en":"Available phosphorus content","parameters":[{"name":"Zakres","range":"(1,0 – 50) mg/100g P2O5"}],"parameters_en":[{"name":"Range","range":"(1,0 – 50) mg/100g P2O5"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość fosforu przyswajalnego\nZakres (1,0 – 50) mg/100g P2O5\nMetoda spektrofotometryczna","reference":"PN-R-04023:1996","norm_bases":["PN-R-04023:1996"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Gleba Zawartość fosforu przyswajalnego\nZakres (1,0 – 50) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04023:1996 Gleba Zawartosc fosforu przyswajalnego\nZakres (1,0 – 50) mg/100g P2O5\nMetoda spektrofotometryczna PN-R-04023:1996","categories":["environment"],"row_index":104,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Soil Available phosphorus content Spectrophotometric method Range PN-R-04023:1996","parameters_zh":[{"name":"范围","range":"(1,0 – 50) mg/100g P2O5"}],"search_zh":"土壤 有效磷含量 分光光度法 范围 PN-R-04023:1996","technique_zh":"分光光度法","test_object_zh":"土壤","methodology_zh":"有效磷含量"},{"_id":"6a5dc9bbf1c10c8ce825de1e","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"pH - w KCl, pH - w CaCl2, pH - w H2O","methodology_en":"pH - in KCl, pH - in CaCl2, pH - in H2O","parameters":[{"name":"Zakres","range":"4,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH - w KCl, pH - w CaCl2, pH - w H2O\nZakres 4,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe pH - w KCl, pH - w CaCl2, pH - w H2O\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Osady sciekowe pH - w KCl, pH - w CaCl2, pH - w H2O\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["water"],"row_index":105,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge pH - in KCl, pH - in CaCl2, pH - in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","parameters_zh":[{"name":"范围","range":"4,0 – 12,0"}],"search_zh":"污泥 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a5dc9bbf1c10c8ce825de1f","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu","methodology_en":"Loss on ignition of dry matter (LOI) / Residue on ignition","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Straty przy prażeniu suchej masy (LOI) / Pozostałość po prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 Osady sciekowe Straty przy prazeniu suchej masy (LOI) / Pozostalosc po prazeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["water"],"row_index":106,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Loss on ignition of dry matter (LOI) / Residue on ignition Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"污泥 干物质烧失量（LOI）/ 灼烧残渣 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质烧失量（LOI）/ 灼烧残渣"},{"_id":"6a5dc9bbf1c10c8ce825de20","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Sucha masa / zawartość wody","methodology_en":"Dry matter / water content","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha masa / zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Sucha masa / zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 Osady sciekowe Sucha masa / zawartosc wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02","categories":["water"],"row_index":107,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Dry matter / water content Gravimetric method Range PN-EN 15934:2013-02","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"污泥 干物质 / 水分含量 重量法 范围 PN-EN 15934:2013-02","technique_zh":"重量法","test_object_zh":"污泥","methodology_zh":"干物质 / 水分含量"},{"_id":"6a5dc9bbf1c10c8ce825de21","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen content","parameters":[{"name":"Zakres","range":"(0,20 – 7,0) %"}],"parameters_en":[{"name":"Range","range":"(0,20 – 7,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,20 – 7,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu Kjeldahla\nZakres (0,20 – 7,0) %\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu Kjeldahla\nZakres (0,20 – 7,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":108,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","parameters_zh":[{"name":"范围","range":"(0,20 – 7,0) %"}],"search_zh":"污泥 凯氏氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏氮含量"},{"_id":"6a5dc9bbf1c10c8ce825de22","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość azotu amonowego","methodology_en":"Ammonium nitrogen content","parameters":[{"name":"Zakres","range":"(0,10 – 100) g/kg"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) g/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu amonowego\nZakres (0,10 – 100) g/kg\nMetoda miareczkowa","reference":"PN-EN 14671:2007 | PN-ISO 5664:2002","norm_bases":["PN-EN 14671:2007","PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres (0,10 – 100) g/kg\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002 Osady sciekowe Zawartosc azotu amonowego\nZakres (0,10 – 100) g/kg\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002","categories":["water"],"row_index":109,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Range PN-EN 14671:2007 | PN-ISO 5664:2002","parameters_zh":[{"name":"范围","range":"(0,10 – 100) g/kg"}],"search_zh":"污泥 氨氮含量 滴定法 范围 PN-EN 14671:2007 | PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a5dc9bbf1c10c8ce825de23","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość fosforu ogólnego","methodology_en":"Total phosphorus content","parameters":[{"name":"Zakres","range":"(0,50 – 8,0) %"}],"parameters_en":[{"name":"Range","range":"(0,50 – 8,0) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,50 – 8,0) %\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN 14672:2006","PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres (0,50 – 8,0) %\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 Osady sciekowe Zawartosc fosforu ogolnego\nZakres (0,50 – 8,0) %\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":110,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Range PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,50 – 8,0) %"}],"search_zh":"污泥 总磷含量 分光光度法 范围 PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a5dc9bbf1c10c8ce825de24","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość wapnia","methodology_en":"Calcium content","parameters":[{"name":"Zakres","range":"(0,10 – 15) %"},{"name":"Zawartość magnezu"},{"name":"Zakres","range":"(0,080 – 1,5) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 15) %"},{"name":"Magnesium content"},{"name":"Range","range":"(0,080 – 1,5) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość wapnia\nZakres:\nZakres (0,10 – 15) %\nZawartość magnezu\nZakres (0,080 – 1,5) %\nMetoda miareczkowa","reference":"PS-11 edycja 3 z dnia 22.02.2013 r.","norm_bases":["PS-11 edycja 3 z dnia 22.02.2013 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość wapnia\nZakres:\nZakres (0,10 – 15) %\nZawartość magnezu\nZakres (0,080 – 1,5) %\nMetoda miareczkowa PS-11 edycja 3 z dnia 22.02.2013 r. Osady sciekowe Zawartosc wapnia\nZakres:\nZakres (0,10 – 15) %\nZawartosc magnezu\nZakres (0,080 – 1,5) %\nMetoda miareczkowa PS-11 edycja 3 z dnia 22.02.2013 r.","categories":["water"],"row_index":111,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Calcium content Titrimetric method Range Magnesium content Range PS-11 edycja 3 z dnia 22.02.2013 r.","parameters_zh":[{"name":"范围","range":"(0,10 – 15) %"},{"name":"镁含量"},{"name":"范围","range":"(0,080 – 1,5) %"}],"search_zh":"污泥 钙含量 滴定法 范围 镁含量 范围 PS-11 edycja 3 z dnia 22.02.2013 r.","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"钙含量"},{"_id":"6a5dc9bbf1c10c8ce825de25","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Osady ściekowe","test_object_en":"Sewage sludge","methodology":"Zawartość pierwiastków","methodology_en":"Element content","parameters":[{"name":"Chrom","range":"(1,0 – 5000) mg/kg"},{"name":"Cynk","range":"(10 – 10000) mg/kg"},{"name":"Ołów","range":"(0,1 – 5000) mg/kg"},{"name":"Kadm","range":"(0,05 – 50) mg/kg"},{"name":"Nikiel","range":"(0,2 – 5000) mg/kg"},{"name":"Miedź","range":"(5,0 – 5000) mg/kg"},{"name":"Rtęć","range":"(0,5 – 50) mg/kg"},{"name":"Fosfor","range":"(1,0 – 5000) mg/kg"},{"name":"Magnez","range":"(100 – 15 000) mg/kg"},{"name":"Zakres","range":"(0,010 – 1,50) %"},{"name":"Wapń","range":"(100 –150 000) mg/kg"},{"name":"(0,010– 15,0) %"}],"parameters_en":[{"name":"Chromium","range":"(1,0 – 5000) mg/kg"},{"name":"Zinc","range":"(10 – 10000) mg/kg"},{"name":"Lead","range":"(0,1 – 5000) mg/kg"},{"name":"Cadmium","range":"(0,05 – 50) mg/kg"},{"name":"Nickel","range":"(0,2 – 5000) mg/kg"},{"name":"Copper","range":"(5,0 – 5000) mg/kg"},{"name":"Mercury","range":"(0,5 – 50) mg/kg"},{"name":"Phosphorus","range":"(1,0 – 5000) mg/kg"},{"name":"Magnesium","range":"(100 – 15 000) mg/kg"},{"name":"Range","range":"(0,010 – 1,50) %"},{"name":"Calcium","range":"(100 –150 000) mg/kg"},{"name":"(0,010– 15,0) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP–OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP–OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP–OES)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków\nZakres:\nChrom (1,0 – 5000) mg/kg\nCynk (10 – 10000) mg/kg\nOłów (0,1 – 5000) mg/kg\nKadm (0,05 – 50) mg/kg\nNikiel (0,2 – 5000) mg/kg\nMiedź (5,0 – 5000) mg/kg\nRtęć (0,5 – 50) mg/kg\nFosfor (1,0 – 5000) mg/kg\nMagnez (100 – 15 000) mg/kg\nZakres (0,010 – 1,50) %\nWapń (100 –150 000) mg/kg\n(0,010– 15,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP–OES)","reference":"PN-EN 16170:2017-02","norm_bases":["PN-EN 16170:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Osady ściekowe Zawartość pierwiastków\nZakres:\nChrom (1,0 – 5000) mg/kg\nCynk (10 – 10000) mg/kg\nOłów (0,1 – 5000) mg/kg\nKadm (0,05 – 50) mg/kg\nNikiel (0,2 – 5000) mg/kg\nMiedź (5,0 – 5000) mg/kg\nRtęć (0,5 – 50) mg/kg\nFosfor (1,0 – 5000) mg/kg\nMagnez (100 – 15 000) mg/kg\nZakres (0,010 – 1,50) %\nWapń (100 –150 000) mg/kg\n(0,010– 15,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP–OES) PN-EN 16170:2017-02 Osady sciekowe Zawartosc pierwiastkow\nZakres:\nChrom (1,0 – 5000) mg/kg\nCynk (10 – 10000) mg/kg\nOlow (0,1 – 5000) mg/kg\nKadm (0,05 – 50) mg/kg\nNikiel (0,2 – 5000) mg/kg\nMiedz (5,0 – 5000) mg/kg\nRtec (0,5 – 50) mg/kg\nFosfor (1,0 – 5000) mg/kg\nMagnez (100 – 15 000) mg/kg\nZakres (0,010 – 1,50) %\nWapn (100 –150 000) mg/kg\n(0,010– 15,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP–OES) PN-EN 16170:2017-02","categories":["water","materials"],"row_index":112,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Sewage sludge Element content Inductively coupled plasma optical emission spectrometry (ICP–OES) Chromium Zinc Lead Cadmium Nickel Copper Mercury Phosphorus Magnesium Range Calcium (0,010– 15,0) % PN-EN 16170:2017-02","methodology_zh":"元素含量","parameters_zh":[{"name":"铬","range":"(1,0 – 5000) mg/kg"},{"name":"锌","range":"(10 – 10000) mg/kg"},{"name":"铅","range":"(0,1 – 5000) mg/kg"},{"name":"镉","range":"(0,05 – 50) mg/kg"},{"name":"镍","range":"(0,2 – 5000) mg/kg"},{"name":"铜","range":"(5,0 – 5000) mg/kg"},{"name":"汞","range":"(0,5 – 50) mg/kg"},{"name":"磷","range":"(1,0 – 5000) mg/kg"},{"name":"镁","range":"(100 – 15 000) mg/kg"},{"name":"范围","range":"(0,010 – 1,50) %"},{"name":"钙","range":"(100 –150 000) mg/kg"},{"name":"(0,010– 15,0) %"}],"search_zh":"污泥 元素含量 铬 锌 铅 镉 镍 铜 汞 磷 镁 范围 钙 PN-EN 16170:2017-02","test_object_zh":"污泥"},{"_id":"6a5dc9bbf1c10c8ce825de26","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 05","test_object_en":"Waste o) code: 19 08 05","methodology":"Pobieranie próbek do badań chemicznych i fizycznych mikrobiologicznych i parazytologicznych","methodology_en":"Sampling for chemical and physical, microbiological and parasitological testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych mikrobiologicznych i parazytologicznych","reference":"PN-EN ISO 5667-13:2011 z wył. 6.3.5, 6.3.8.5","norm_bases":["PN-EN ISO 5667-13:2011 z wył. 6.3.5, 6.3.8.5"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 05 Pobieranie próbek do badań chemicznych i fizycznych mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 z wył. 6.3.5, 6.3.8.5 Odpady o) kod: 19 08 05 Pobieranie probek do badan chemicznych i fizycznych mikrobiologicznych i parazytologicznych PN-EN ISO 5667-13:2011 z wyl. 6.3.5, 6.3.8.5","categories":["environment","microbiology"],"row_index":113,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 05 Sampling for chemical and physical, microbiological and parasitological testing PN-EN ISO 5667-13:2011 z wył. 6.3.5, 6.3.8.5","search_zh":"废物 o) 代码：19 08 05 PN-EN ISO 5667-13:2011 z wył. 6.3.5, 6.3.8.5","test_object_zh":"废物 o) 代码：19 08 05"},{"_id":"6a5dc9bbf1c10c8ce825de27","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 05","test_object_en":"Waste o) code: 19 08 05","methodology":"pH - w KCl, pH - w CaCl2, pH - w H2O","methodology_en":"pH - in KCl, pH - in CaCl2, pH - in H2O","parameters":[{"name":"Zakres","range":"4,0 – 12,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 12,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH - w KCl, pH - w CaCl2, pH - w H2O\nZakres 4,0 – 12,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10390:2022-09","norm_bases":["PN-EN ISO 10390:2022-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 05 pH - w KCl, pH - w CaCl2, pH - w H2O\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09 Odpady o) kod: 19 08 05 pH - w KCl, pH - w CaCl2, pH - w H2O\nZakres 4,0 – 12,0\nMetoda potencjometryczna PN-EN ISO 10390:2022-09","categories":["environment"],"row_index":114,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 05 pH - in KCl, pH - in CaCl2, pH - in H2O Potentiometric method Range PN-EN ISO 10390:2022-09","parameters_zh":[{"name":"范围","range":"4,0 – 12,0"}],"search_zh":"废物 o) 代码：19 08 05 电位法 范围 PN-EN ISO 10390:2022-09","technique_zh":"电位法","test_object_zh":"废物 o) 代码：19 08 05"},{"_id":"6a5dc9bbf1c10c8ce825de28","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 05","test_object_en":"Waste o) code: 19 08 05","methodology":"Straty przy prażeniu suchej masy (LOI)/ Pozostałość po prażeniu","methodology_en":"Loss on ignition of dry matter (LOI)/ Residue on ignition","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Straty przy prażeniu suchej masy (LOI)/ Pozostałość po prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15935:2022-01","norm_bases":["PN-EN 15935:2022-01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 05 Straty przy prażeniu suchej masy (LOI)/ Pozostałość po prażeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01 Odpady o) kod: 19 08 05 Straty przy prazeniu suchej masy (LOI)/ Pozostalosc po prazeniu\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15935:2022-01","categories":["environment"],"row_index":115,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 05 Loss on ignition of dry matter (LOI)/ Residue on ignition Gravimetric method Range PN-EN 15935:2022-01","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"废物 o) 代码：19 08 05 重量法 范围 PN-EN 15935:2022-01","technique_zh":"重量法","test_object_zh":"废物 o) 代码：19 08 05"},{"_id":"6a5dc9bbf1c10c8ce825de29","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 05","test_object_en":"Waste o) code: 19 08 05","methodology":"Sucha masa / zawartość wody","methodology_en":"Dry matter / water content","parameters":[{"name":"Zakres","range":"(1,0 – 99,0) %"}],"parameters_en":[{"name":"Range","range":"(1,0 – 99,0) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Sucha masa / zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa","reference":"PN-EN 15934:2013-02","norm_bases":["PN-EN 15934:2013-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 05 Sucha masa / zawartość wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02 Odpady o) kod: 19 08 05 Sucha masa / zawartosc wody\nZakres (1,0 – 99,0) %\nMetoda wagowa PN-EN 15934:2013-02","categories":["environment","water"],"row_index":116,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 05 Dry matter / water content Gravimetric method Range PN-EN 15934:2013-02","parameters_zh":[{"name":"范围","range":"(1,0 – 99,0) %"}],"search_zh":"废物 o) 代码：19 08 05 干物质 / 水分含量 重量法 范围 PN-EN 15934:2013-02","technique_zh":"重量法","methodology_zh":"干物质 / 水分含量","test_object_zh":"废物 o) 代码：19 08 05"},{"_id":"6a5dc9bbf1c10c8ce825de2a","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 05","test_object_en":"Waste o) code: 19 08 05","methodology":"Zawartość azotu Kjeldahla","methodology_en":"Kjeldahl nitrogen content","parameters":[{"name":"Zakres","range":"(0,20 – 7,0) %"}],"parameters_en":[{"name":"Range","range":"(0,20 – 7,0) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu Kjeldahla\nZakres (0,20 – 7,0) %\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 05 Zawartość azotu Kjeldahla\nZakres (0,20 – 7,0) %\nMetoda miareczkowa PN-EN 13342:2002 Odpady o) kod: 19 08 05 Zawartosc azotu Kjeldahla\nZakres (0,20 – 7,0) %\nMetoda miareczkowa PN-EN 13342:2002","categories":["environment"],"row_index":117,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 05 Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","parameters_zh":[{"name":"范围","range":"(0,20 – 7,0) %"}],"search_zh":"废物 o) 代码：19 08 05 凯氏氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","methodology_zh":"凯氏氮含量","test_object_zh":"废物 o) 代码：19 08 05"},{"_id":"6a5dc9bbf1c10c8ce825de2b","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 05","test_object_en":"Waste o) code: 19 08 05","methodology":"Zawartość azotu amonowego","methodology_en":"Ammonium nitrogen content","parameters":[{"name":"Zakres","range":"(0,10 – 100) g/kg"}],"parameters_en":[{"name":"Range","range":"(0,10 – 100) g/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość azotu amonowego\nZakres (0,10 – 100) g/kg\nMetoda miareczkowa","reference":"PN-EN 14671:2007 | PN-ISO 5664:2002","norm_bases":["PN-EN 14671:2007","PN-ISO 5664:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 05 Zawartość azotu amonowego\nZakres (0,10 – 100) g/kg\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002 Odpady o) kod: 19 08 05 Zawartosc azotu amonowego\nZakres (0,10 – 100) g/kg\nMetoda miareczkowa PN-EN 14671:2007 | PN-ISO 5664:2002","categories":["environment"],"row_index":118,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 05 Ammonium nitrogen content Titrimetric method Range PN-EN 14671:2007 | PN-ISO 5664:2002","parameters_zh":[{"name":"范围","range":"(0,10 – 100) g/kg"}],"search_zh":"废物 o) 代码：19 08 05 氨氮含量 滴定法 范围 PN-EN 14671:2007 | PN-ISO 5664:2002","technique_zh":"滴定法","methodology_zh":"氨氮含量","test_object_zh":"废物 o) 代码：19 08 05"},{"_id":"6a5dc9bbf1c10c8ce825de2c","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 05","test_object_en":"Waste o) code: 19 08 05","methodology":"Zawartość fosforu ogólnego","methodology_en":"Total phosphorus content","parameters":[{"name":"Zakres","range":"(0,50 – 8,0) %"}],"parameters_en":[{"name":"Range","range":"(0,50 – 8,0) %"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Zawartość fosforu ogólnego\nZakres (0,50 – 8,0) %\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN 14672:2006","PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 05 Zawartość fosforu ogólnego\nZakres (0,50 – 8,0) %\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010 Odpady o) kod: 19 08 05 Zawartosc fosforu ogolnego\nZakres (0,50 – 8,0) %\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010","categories":["environment"],"row_index":119,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 05 Total phosphorus content Spectrophotometric method Range PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010","parameters_zh":[{"name":"范围","range":"(0,50 – 8,0) %"}],"search_zh":"废物 o) 代码：19 08 05 总磷含量 分光光度法 范围 PN-EN 14672:2006 | PN-EN ISO 6878:2006 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","methodology_zh":"总磷含量","test_object_zh":"废物 o) 代码：19 08 05"},{"_id":"6a5dc9bbf1c10c8ce825de2d","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 05","test_object_en":"Waste o) code: 19 08 05","methodology":"Zawartość wapnia","methodology_en":"Calcium content","parameters":[{"name":"Zakres","range":"(0,10 – 15) %"}],"parameters_en":[{"name":"Range","range":"(0,10 – 15) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość wapnia\nZakres (0,10 – 15) %\nMetoda miareczkowa","reference":"PS-11 edycja 3 z dnia 22.02.2013 r.","norm_bases":["PS-11 edycja 3 z dnia 22.02.2013 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 05 Zawartość wapnia\nZakres (0,10 – 15) %\nMetoda miareczkowa PS-11 edycja 3 z dnia 22.02.2013 r. Odpady o) kod: 19 08 05 Zawartosc wapnia\nZakres (0,10 – 15) %\nMetoda miareczkowa PS-11 edycja 3 z dnia 22.02.2013 r.","categories":["environment"],"row_index":120,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 05 Calcium content Titrimetric method Range PS-11 edycja 3 z dnia 22.02.2013 r.","parameters_zh":[{"name":"范围","range":"(0,10 – 15) %"}],"search_zh":"废物 o) 代码：19 08 05 钙含量 滴定法 范围 PS-11 edycja 3 z dnia 22.02.2013 r.","technique_zh":"滴定法","methodology_zh":"钙含量","test_object_zh":"废物 o) 代码：19 08 05"},{"_id":"6a5dc9bbf1c10c8ce825de2e","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 05","test_object_en":"Waste o) code: 19 08 05","methodology":"Zawartość magnezu","methodology_en":"Magnesium content","parameters":[{"name":"Zakres","range":"(0,080 – 1,5) %"}],"parameters_en":[{"name":"Range","range":"(0,080 – 1,5) %"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość magnezu\nZakres (0,080 – 1,5) %\nMetoda miareczkowa","reference":"PS-11 edycja 3 z dnia 22.02.2013 r.","norm_bases":["PS-11 edycja 3 z dnia 22.02.2013 r."],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 05 Zawartość magnezu\nZakres (0,080 – 1,5) %\nMetoda miareczkowa PS-11 edycja 3 z dnia 22.02.2013 r. Odpady o) kod: 19 08 05 Zawartosc magnezu\nZakres (0,080 – 1,5) %\nMetoda miareczkowa PS-11 edycja 3 z dnia 22.02.2013 r.","categories":["environment"],"row_index":121,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 05 Magnesium content Titrimetric method Range PS-11 edycja 3 z dnia 22.02.2013 r.","parameters_zh":[{"name":"范围","range":"(0,080 – 1,5) %"}],"search_zh":"废物 o) 代码：19 08 05 镁含量 滴定法 范围 PS-11 edycja 3 z dnia 22.02.2013 r.","technique_zh":"滴定法","methodology_zh":"镁含量","test_object_zh":"废物 o) 代码：19 08 05"},{"_id":"6a5dc9bbf1c10c8ce825de2f","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 05","test_object_en":"Waste o) code: 19 08 05","methodology":"Zawartość pierwiastków","methodology_en":"Element content","parameters":[{"name":"Chrom","range":"(1,0 – 5000) mg/kg"},{"name":"Cynk","range":"(10 – 10000) mg/kg"},{"name":"Ołów","range":"(0,1 – 5000) mg/kg"},{"name":"Kadm","range":"(0,05 – 50) mg/kg"},{"name":"Nikiel","range":"(0,2 – 5000) mg/kg"},{"name":"Miedź","range":"(5,0 – 5000) mg/kg"},{"name":"Rtęć","range":"(0,5 – 50) mg/kg"},{"name":"Fosfor","range":"(1,0 – 5000) mg/kg"},{"name":"Magnez","range":"(100 – 15 000) mg/kg"},{"name":"Zakres","range":"(0,010 – 1,50) %"},{"name":"Wapń","range":"(100 – 150 000) mg/kg"},{"name":"(0,010– 15,0) %"}],"parameters_en":[{"name":"Chromium","range":"(1,0 – 5000) mg/kg"},{"name":"Zinc","range":"(10 – 10000) mg/kg"},{"name":"Lead","range":"(0,1 – 5000) mg/kg"},{"name":"Cadmium","range":"(0,05 – 50) mg/kg"},{"name":"Nickel","range":"(0,2 – 5000) mg/kg"},{"name":"Copper","range":"(5,0 – 5000) mg/kg"},{"name":"Mercury","range":"(0,5 – 50) mg/kg"},{"name":"Phosphorus","range":"(1,0 – 5000) mg/kg"},{"name":"Magnesium","range":"(100 – 15 000) mg/kg"},{"name":"Range","range":"(0,010 – 1,50) %"},{"name":"Calcium","range":"(100 – 150 000) mg/kg"},{"name":"(0,010– 15,0) %"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP–OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP–OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP–OES)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków\nZakres:\nChrom (1,0 – 5000) mg/kg\nCynk (10 – 10000) mg/kg\nOłów (0,1 – 5000) mg/kg\nKadm (0,05 – 50) mg/kg\nNikiel (0,2 – 5000) mg/kg\nMiedź (5,0 – 5000) mg/kg\nRtęć (0,5 – 50) mg/kg\nFosfor (1,0 – 5000) mg/kg\nMagnez (100 – 15 000) mg/kg\nZakres (0,010 – 1,50) %\nWapń (100 – 150 000) mg/kg\n(0,010– 15,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP–OES)","reference":"PN-EN 16170:2017-02","norm_bases":["PN-EN 16170:2017-02"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 05 Zawartość pierwiastków\nZakres:\nChrom (1,0 – 5000) mg/kg\nCynk (10 – 10000) mg/kg\nOłów (0,1 – 5000) mg/kg\nKadm (0,05 – 50) mg/kg\nNikiel (0,2 – 5000) mg/kg\nMiedź (5,0 – 5000) mg/kg\nRtęć (0,5 – 50) mg/kg\nFosfor (1,0 – 5000) mg/kg\nMagnez (100 – 15 000) mg/kg\nZakres (0,010 – 1,50) %\nWapń (100 – 150 000) mg/kg\n(0,010– 15,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP–OES) PN-EN 16170:2017-02 Odpady o) kod: 19 08 05 Zawartosc pierwiastkow\nZakres:\nChrom (1,0 – 5000) mg/kg\nCynk (10 – 10000) mg/kg\nOlow (0,1 – 5000) mg/kg\nKadm (0,05 – 50) mg/kg\nNikiel (0,2 – 5000) mg/kg\nMiedz (5,0 – 5000) mg/kg\nRtec (0,5 – 50) mg/kg\nFosfor (1,0 – 5000) mg/kg\nMagnez (100 – 15 000) mg/kg\nZakres (0,010 – 1,50) %\nWapn (100 – 150 000) mg/kg\n(0,010– 15,0) %\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP–OES) PN-EN 16170:2017-02","categories":["environment","materials"],"row_index":122,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 05 Element content Inductively coupled plasma optical emission spectrometry (ICP–OES) Chromium Zinc Lead Cadmium Nickel Copper Mercury Phosphorus Magnesium Range Calcium (0,010– 15,0) % PN-EN 16170:2017-02","methodology_zh":"元素含量","parameters_zh":[{"name":"铬","range":"(1,0 – 5000) mg/kg"},{"name":"锌","range":"(10 – 10000) mg/kg"},{"name":"铅","range":"(0,1 – 5000) mg/kg"},{"name":"镉","range":"(0,05 – 50) mg/kg"},{"name":"镍","range":"(0,2 – 5000) mg/kg"},{"name":"铜","range":"(5,0 – 5000) mg/kg"},{"name":"汞","range":"(0,5 – 50) mg/kg"},{"name":"磷","range":"(1,0 – 5000) mg/kg"},{"name":"镁","range":"(100 – 15 000) mg/kg"},{"name":"范围","range":"(0,010 – 1,50) %"},{"name":"钙","range":"(100 – 150 000) mg/kg"},{"name":"(0,010– 15,0) %"}],"search_zh":"废物 o) 代码：19 08 05 元素含量 铬 锌 铅 镉 镍 铜 汞 磷 镁 范围 钙 PN-EN 16170:2017-02","test_object_zh":"废物 o) 代码：19 08 05"},{"_id":"6a5dc9bbf1c10c8ce825de30","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 05","test_object_en":"Waste o) code: 19 08 05","methodology":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp.","methodology_en":"Presence and count of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp.","parameters":[{"name":"Zakres","range":"od 1 ATT/kg s.m."}],"parameters_en":[{"name":"Range","range":"od 1 ATT/kg s.m."}],"technique":"Metoda flotacji, mikroskopowa","techniques":["Metoda flotacji, mikroskopowa"],"technique_en":"Flotation method, microscopic","computed":[],"computed_en":[],"activity":"Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp.\nZakres od 1 ATT/kg s.m.\nMetoda flotacji, mikroskopowa","reference":"PN-Z-19005:2018","norm_bases":["PN-Z-19005:2018"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 05 Obecność i liczba żywych jaj pasożytów jelitowych Ascaris sp., Toxocara sp., Trichuris sp.\nZakres od 1 ATT/kg s.m.\nMetoda flotacji, mikroskopowa PN-Z-19005:2018 Odpady o) kod: 19 08 05 Obecnosc i liczba zywych jaj pasozytow jelitowych Ascaris sp., Toxocara sp., Trichuris sp.\nZakres od 1 ATT/kg s.m.\nMetoda flotacji, mikroskopowa PN-Z-19005:2018","categories":["environment"],"row_index":123,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 05 Presence and count of viable eggs of intestinal parasites Ascaris sp., Toxocara sp., Trichuris sp. Flotation method, microscopic Range PN-Z-19005:2018","parameters_zh":[{"name":"范围","range":"od 1 ATT/kg s.m."}],"search_zh":"废物 o) 代码：19 08 05 浮选显微镜法 范围 PN-Z-19005:2018","technique_zh":"浮选显微镜法","test_object_zh":"废物 o) 代码：19 08 05"},{"_id":"6a5dc9bbf1c10c8ce825de31","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 05","test_object_en":"Waste o) code: 19 08 05","methodology":"Obecność bakterii z rodzaju, Salmonella","methodology_en":"Presence of bacteria of the genus, Salmonella","parameters":[],"parameters_en":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"technique_en":"Culture method with biochemical and serological confirmation","computed":[],"computed_en":[],"activity":"Obecność bakterii z rodzaju, Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020- 09","norm_bases":["PN-EN ISO 6579-1:2017-04","PN-EN ISO 6579-1:2017-04/ A1:2020- 09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 05 Obecność bakterii z rodzaju, Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020- 09 Odpady o) kod: 19 08 05 Obecnosc bakterii z rodzaju, Salmonella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020- 09","categories":["microbiology","environment"],"row_index":124,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 05 Presence of bacteria of the genus, Salmonella Culture method with biochemical and serological confirmation PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020- 09","search_zh":"废物 o) 代码：19 08 05 沙门氏菌属细菌的检出 培养法结合生化与血清学确认 PN-EN ISO 6579-1:2017-04 | PN-EN ISO 6579-1:2017-04/ A1:2020- 09","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"沙门氏菌属细菌的检出","test_object_zh":"废物 o) 代码：19 08 05"},{"_id":"6a5dc9bbf1c10c8ce825de32","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13","test_object_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","methodology_en":"Sampling for chemical and physical testing","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8","norm_bases":["PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8 Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011 z wyl. 6.3.4; 6.3.5; 6.3.8","categories":["environment"],"row_index":125,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Sampling for chemical and physical testing PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8","methodology_zh":"化学与物理检测用样品采集","search_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13 化学与物理检测用样品采集 PN-EN ISO 5667-13:2011 z wył. 6.3.4; 6.3.5; 6.3.8","test_object_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13"},{"_id":"6a5dc9bbf1c10c8ce825de33","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13","test_object_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13","methodology":"Całkowite substancje rozpuszczone (TDS)","methodology_en":"Total dissolved solids (TDS)","parameters":[{"name":"Zakres","range":"(10 – 7500) mg/kg"}],"parameters_en":[{"name":"Range","range":"(10 – 7500) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Całkowite substancje rozpuszczone (TDS)\nZakres (10 – 7500) mg/kg\nMetoda wagowa","reference":"PN-EN 15216:2022-03 | PN-EN 12457-4:2006","norm_bases":["PN-EN 15216:2022-03","PN-EN 12457-4:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Całkowite substancje rozpuszczone (TDS)\nZakres (10 – 7500) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-4:2006 Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Calkowite substancje rozpuszczone (TDS)\nZakres (10 – 7500) mg/kg\nMetoda wagowa PN-EN 15216:2022-03 | PN-EN 12457-4:2006","categories":["environment"],"row_index":126,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Total dissolved solids (TDS) Gravimetric method Range PN-EN 15216:2022-03 | PN-EN 12457-4:2006","parameters_zh":[{"name":"范围","range":"(10 – 7500) mg/kg"}],"search_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13 溶解性总固体（TDS） 重量法 范围 PN-EN 15216:2022-03 | PN-EN 12457-4:2006","technique_zh":"重量法","methodology_zh":"溶解性总固体（TDS）","test_object_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13"},{"_id":"6a5dc9bbf1c10c8ce825de34","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13","test_object_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13","methodology":"Zawartość siarczanów","methodology_en":"Sulfate content","parameters":[{"name":"Zakres","range":"(100 – 2500) mg/kg"}],"parameters_en":[{"name":"Range","range":"(100 – 2500) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"technique_en":"Gravimetric method","computed":[],"computed_en":[],"activity":"Zawartość siarczanów\nZakres (100 – 2500) mg/kg\nMetoda wagowa","reference":"PN-ISO 9280:2002 | PN-EN 12457-4:2006","norm_bases":["PN-ISO 9280:2002","PN-EN 12457-4:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Zawartość siarczanów\nZakres (100 – 2500) mg/kg\nMetoda wagowa PN-ISO 9280:2002 | PN-EN 12457-4:2006 Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Zawartosc siarczanow\nZakres (100 – 2500) mg/kg\nMetoda wagowa PN-ISO 9280:2002 | PN-EN 12457-4:2006","categories":["environment"],"row_index":127,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Sulfate content Gravimetric method Range PN-ISO 9280:2002 | PN-EN 12457-4:2006","parameters_zh":[{"name":"范围","range":"(100 – 2500) mg/kg"}],"search_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13 硫酸盐含量 重量法 范围 PN-ISO 9280:2002 | PN-EN 12457-4:2006","technique_zh":"重量法","methodology_zh":"硫酸盐含量","test_object_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13"},{"_id":"6a5dc9bbf1c10c8ce825de35","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13","test_object_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13","methodology":"Zawartość chlorków","methodology_en":"Chloride content","parameters":[{"name":"Zakres","range":"(50 – 10000) mg/kg"}],"parameters_en":[{"name":"Range","range":"(50 – 10000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Zawartość chlorków\nZakres (50 – 10000) mg/kg\nMetoda miareczkowa","reference":"PN-ISO 9297:1994 | PN-EN 12457-4:2006","norm_bases":["PN-ISO 9297:1994","PN-EN 12457-4:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Zawartość chlorków\nZakres (50 – 10000) mg/kg\nMetoda miareczkowa PN-ISO 9297:1994 | PN-EN 12457-4:2006 Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Zawartosc chlorkow\nZakres (50 – 10000) mg/kg\nMetoda miareczkowa PN-ISO 9297:1994 | PN-EN 12457-4:2006","categories":["environment"],"row_index":128,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Chloride content Titrimetric method Range PN-ISO 9297:1994 | PN-EN 12457-4:2006","parameters_zh":[{"name":"范围","range":"(50 – 10000) mg/kg"}],"search_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13 氯化物含量 滴定法 范围 PN-ISO 9297:1994 | PN-EN 12457-4:2006","technique_zh":"滴定法","methodology_zh":"氯化物含量","test_object_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13"},{"_id":"6a5dc9bbf1c10c8ce825de36","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13","test_object_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13","methodology":"Zawartość anionów","methodology_en":"Anion content","parameters":[{"name":"siarczany","range":"(100 – 2500) mg/kg"},{"name":"chlorki","range":"(10 – 10000) mg/kg"},{"name":"fluorki","range":"(1,0 – 100) mg/kg"}],"parameters_en":[{"name":"sulfates","range":"(100 – 2500) mg/kg"},{"name":"chlorides","range":"(10 – 10000) mg/kg"},{"name":"fluorides","range":"(1,0 – 100) mg/kg"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC–CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC–CD)"],"technique_en":"Ion chromatography with conductometric detection (IC–CD)","computed":[],"computed_en":[],"activity":"Zawartość anionów\nZakres:\nsiarczany (100 – 2500) mg/kg\nchlorki (10 – 10000) mg/kg\nfluorki (1,0 – 100) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC–CD)","reference":"PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 10304-1:2009+AC:2012","PN-EN 12457-4:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Zawartość anionów\nZakres:\nsiarczany (100 – 2500) mg/kg\nchlorki (10 – 10000) mg/kg\nfluorki (1,0 – 100) mg/kg\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC–CD) PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006 Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Zawartosc anionow\nZakres:\nsiarczany (100 – 2500) mg/kg\nchlorki (10 – 10000) mg/kg\nfluorki (1,0 – 100) mg/kg\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC–CD) PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006","categories":["environment"],"row_index":129,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Anion content Ion chromatography with conductometric detection (IC–CD) sulfates chlorides fluorides PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006","parameters_zh":[{"name":"硫酸盐","range":"(100 – 2500) mg/kg"},{"name":"氯化物","range":"(10 – 10000) mg/kg"},{"name":"氟化物","range":"(1,0 – 100) mg/kg"}],"search_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13 阴离子含量 硫酸盐 氯化物 氟化物 PN-EN ISO 10304-1:2009+AC:2012 | PN-EN 12457-4:2006","test_object_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13","methodology_zh":"阴离子含量"},{"_id":"6a5dc9bbf1c10c8ce825de37","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13","test_object_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13","methodology":"Zawartość pierwiastków","methodology_en":"Element content","parameters":[{"name":"nikiel","range":"(0,020 – 20,0) mg/kg"},{"name":"miedź","range":"(0,50 – 20,0) mg/kg"},{"name":"ołów","range":"(0,010 – 25,0) mg/kg"},{"name":"kadm","range":"(0,0050 – 10,0) mg/kg"},{"name":"chrom","range":"(0,050 – 20,0) mg/kg"},{"name":"arsen","range":"(0,10 – 20,0) mg/kg"},{"name":"cynk","range":"(1,00 – 100) mg/kg"},{"name":"bar","range":"(0,010 – 40,0) mg/kg"},{"name":"molibden","range":"(0,30 – 20,0) mg/kg"},{"name":"selen","range":"(0,10 – 20,0) mg/kg"}],"parameters_en":[{"name":"nickel","range":"(0,020 – 20,0) mg/kg"},{"name":"copper","range":"(0,50 – 20,0) mg/kg"},{"name":"lead","range":"(0,010 – 25,0) mg/kg"},{"name":"cadmium","range":"(0,0050 – 10,0) mg/kg"},{"name":"chromium","range":"(0,050 – 20,0) mg/kg"},{"name":"arsenic","range":"(0,10 – 20,0) mg/kg"},{"name":"zinc","range":"(1,00 – 100) mg/kg"},{"name":"barium","range":"(0,010 – 40,0) mg/kg"},{"name":"molybdenum","range":"(0,30 – 20,0) mg/kg"},{"name":"selenium","range":"(0,10 – 20,0) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP–OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP–OES)"],"technique_en":"Inductively coupled plasma optical emission spectrometry (ICP–OES)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków\nZakres:\nnikiel (0,020 – 20,0) mg/kg\nmiedź (0,50 – 20,0) mg/kg\nołów (0,010 – 25,0) mg/kg\nkadm (0,0050 – 10,0) mg/kg\nchrom (0,050 – 20,0) mg/kg\narsen (0,10 – 20,0) mg/kg\ncynk (1,00 – 100) mg/kg\nbar (0,010 – 40,0) mg/kg\nmolibden (0,30 – 20,0) mg/kg\nselen (0,10 – 20,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP–OES)","reference":"PN-EN ISO 11885:2009 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 11885:2009","PN-EN 12457-4:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Zawartość pierwiastków\nZakres:\nnikiel (0,020 – 20,0) mg/kg\nmiedź (0,50 – 20,0) mg/kg\nołów (0,010 – 25,0) mg/kg\nkadm (0,0050 – 10,0) mg/kg\nchrom (0,050 – 20,0) mg/kg\narsen (0,10 – 20,0) mg/kg\ncynk (1,00 – 100) mg/kg\nbar (0,010 – 40,0) mg/kg\nmolibden (0,30 – 20,0) mg/kg\nselen (0,10 – 20,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP–OES) PN-EN ISO 11885:2009 | PN-EN 12457-4:2006 Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Zawartosc pierwiastkow\nZakres:\nnikiel (0,020 – 20,0) mg/kg\nmiedz (0,50 – 20,0) mg/kg\nolow (0,010 – 25,0) mg/kg\nkadm (0,0050 – 10,0) mg/kg\nchrom (0,050 – 20,0) mg/kg\narsen (0,10 – 20,0) mg/kg\ncynk (1,00 – 100) mg/kg\nbar (0,010 – 40,0) mg/kg\nmolibden (0,30 – 20,0) mg/kg\nselen (0,10 – 20,0) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP–OES) PN-EN ISO 11885:2009 | PN-EN 12457-4:2006","categories":["environment","materials"],"row_index":130,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Element content Inductively coupled plasma optical emission spectrometry (ICP–OES) nickel copper lead cadmium chromium arsenic zinc barium molybdenum selenium PN-EN ISO 11885:2009 | PN-EN 12457-4:2006","methodology_zh":"元素含量","parameters_zh":[{"name":"镍","range":"(0,020 – 20,0) mg/kg"},{"name":"铜","range":"(0,50 – 20,0) mg/kg"},{"name":"铅","range":"(0,010 – 25,0) mg/kg"},{"name":"镉","range":"(0,0050 – 10,0) mg/kg"},{"name":"铬","range":"(0,050 – 20,0) mg/kg"},{"name":"砷","range":"(0,10 – 20,0) mg/kg"},{"name":"锌","range":"(1,00 – 100) mg/kg"},{"name":"钡","range":"(0,010 – 40,0) mg/kg"},{"name":"钼","range":"(0,30 – 20,0) mg/kg"},{"name":"硒","range":"(0,10 – 20,0) mg/kg"}],"search_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13 元素含量 镍 铜 铅 镉 铬 砷 锌 钡 钼 硒 PN-EN ISO 11885:2009 | PN-EN 12457-4:2006","test_object_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13"},{"_id":"6a5dc9bbf1c10c8ce825de38","lab_id":"69ad52a3de79e566650fb368","country":"PL","accr_number":"AB 667","accr_body":"PCA","test_object":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13","test_object_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13","methodology":"Zawartość pierwiastków","methodology_en":"Element content","parameters":[{"name":"rtęć","range":"(0,0040- 0,10) mg/kg"},{"name":"antymon","range":"(0,010 - 0,15) mg/kg"}],"parameters_en":[{"name":"mercury","range":"(0,0040- 0,10) mg/kg"},{"name":"antimony","range":"(0,010 - 0,15) mg/kg"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","computed":[],"computed_en":[],"activity":"Zawartość pierwiastków\nZakres:\nrtęć (0,0040- 0,10) mg/kg\nantymon (0,010 - 0,15) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009 | PN-EN 12457-4:2006","norm_bases":["PN-EN ISO 11885:2009","PN-EN 12457-4:2006"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Zawartość pierwiastków\nZakres:\nrtęć (0,0040- 0,10) mg/kg\nantymon (0,010 - 0,15) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-4:2006 Odpady o) kod: 19 08 01 19 08 02 10 12 08 10 12 13 Zawartosc pierwiastkow\nZakres:\nrtec (0,0040- 0,10) mg/kg\nantymon (0,010 - 0,15) mg/kg\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009 | PN-EN 12457-4:2006","categories":["environment"],"row_index":131,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Waste o) code: 19 08 01 19 08 02 10 12 08 10 12 13 Element content Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) mercury antimony PN-EN ISO 11885:2009 | PN-EN 12457-4:2006","methodology_zh":"元素含量","search_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13 元素含量 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） 汞 锑 PN-EN ISO 11885:2009 | PN-EN 12457-4:2006","parameters_zh":[{"name":"汞","range":"(0,0040- 0,10) mg/kg"},{"name":"锑","range":"(0,010 - 0,15) mg/kg"}],"technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）","test_object_zh":"废物 o) 代码：19 08 01、19 08 02、10 12 08、10 12 13"}],"has_pdf":true}