🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL

PCA AB 650 • Wołów, Poland • 34 methods

Water & wastewaterMicrobiology

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 650 (Wołów, Poland). Its accreditation scope covers 34 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, water intended for human consumption, Swimming pool water. Most frequently used techniques: Spectrophotometric method, Membrane filtration method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 650
  • Methods in scope: 34
  • Types of test objects: 2
  • Techniques used: 9
  • City: Wołów, Poland
Accreditation number
AB 650
Accreditation body
PCA
Address
W WOŁOWIE, ODDZIAŁ LABORATORYJNY, ul. M. Józefa Piłsudskiego 36, 56-100 Wołów
City
Wołów, Poland

What this laboratory tests (2)

Analytical techniques used (9)

Accreditation scope — test methods (34)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
2 Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
3 Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
4 Water, water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000 (zał. A)
5 Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
6 Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
7 Water, water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
8 Swimming pool water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004
9 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000 (zał. A)
10 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
11 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
12 Water, water intended for human consumption Ammonium ion concentration
Range (0,1 – 1,0) mg/l Ammonium nitrogen concentration Range (0,04 – 0,8) mg/l
Spectrophotometric method PN-C-04576-4:1994
13 Water, water intended for human consumption Nitrite concentration
Range (0,01 – 0,8) mg/l NO2-
Spectrophotometric method PN-EN 26777:1999
14 Water, water intended for human consumption Nitrate concentration
Range (0,1 – 100) mg/l Nitrate nitrogen concentration Range (0,02 – 22,5) mg/l
Spectrophotometric method PN-82/C-04576.08
15 Water, water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
16 Water, water intended for human consumption Electrical conductivity
Range (50 – 3000) μS/cm
Conductometric method PN-EN 27888:1999
17 Water, water intended for human consumption Total iron concentration
Range (30 – 10000) μg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
18 Water, water intended for human consumption Manganese concentration
Range (0,010 – 0,40) mg/l
Spectrophotometric method PN-92/C-04590/03
19 Water, water intended for human consumption Chloride concentration
Range (5,0 – 400) mg/l
Titrimetric method PN-ISO 9297:1994
20 Water, water intended for human consumption Total content of calcium and magnesium (total hardness)
Range (4,0 – 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
21 Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 zał. A
22 Water, water intended for human consumption Calcium concentration
Range (2,0 – 100) mg/l
Titrimetric method PN-ISO 6058:1999
23 Water, water intended for human consumption Fluoride concentration
Range (0,15 – 1,6) mg/l
Spectrophotometric method PN-75/C-04588.01
24 Water, water intended for human consumption Free and total chlorine concentration
Range (0,03 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2011
25 Water, water intended for human consumption Sulfate concentration
Range (1,0 – 300) mg/l
Turbidimetric method PN-79/C-04566.10
26 Water, water intended for human consumption Permanganate index
Range (0,50 – 10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
27 Water, water intended for human consumption Turbidity
Range (0,20 – 20) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
28 Water, water intended for human consumption Colour
Range (5 – 30) mg/l Pt
Visual method PN-EN ISO 7887:2012 Metoda D
29 Water, water intended for human consumption Ammonium ion concentration
Range (0,02 – 1,0) mg/l Ammonium nitrogen concentration Range (0,02 – 0,8) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
30 Swimming pool water pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
31 Swimming pool water Permanganate index
Range (0,50 – 10) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
32 Swimming pool water Turbidity
Range (0,20 – 20) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
33 Swimming pool water Nitrate concentration
Range (0,1 – 100) mg/l
Spectrophotometric method PN-82/C-04576.08
34 Swimming pool water Free and total chlorine concentration
Range (0,03 – 2,0) mg/l
Spectrophotometric method PN-EN ISO 7393-2:2011

Reference standards (23)

PN-75/C-04588.01
PN-79/C-04566.10
PN-82/C-04576.08
PN-92/C-04590/03
PN-C-04554-4:1999 zał. A
PN-C-04576-4:1994
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7393-2:2011
PN-EN ISO 7887:2012 Metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994
PN-Z-11001-3:2000 (zał. A)