{"lab":{"_id":"69ad52a3de79e566650fb356","accr_number":"AB 650","country":"PL","accr_body":"PCA","address":"W WOŁOWIE, ODDZIAŁ LABORATORYJNY, ul. M. Józefa Piłsudskiego 36, 56-100 Wołów","categories":["water","microbiology"],"city":"Wołów","imported_at":"2026-03-08T10:42:43.265Z","methods_count":34,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_650.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w wołowie, oddział laboratoryjny, ul. m. józefa piłsudskiego 36, 56-100 wołów water other microbiology automotive pharma electronics","status":"active","updated_at":"2026-03-08T14:51:33.561Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-03-08T14:51:33.561Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20650,podmiot.html","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water"},{"codes":"K/28; K/29","pl":"Badania mikrobiologiczne wody, wody do spożycia przez ludzi","en":"Microbiological tests of water, drinking water"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"}],"issue":{"no":"18","date":"27.08.2025"},"parse_date":"2026-07-20T07:09:46.669Z","parse_source":"script-pdfplumber","map_coord":[51.336384,16.64869],"map_geo":"nominatim-city","has_en":true,"category_counts":{"water":34,"microbiology":3},"category_scores":{"water":31.24,"microbiology":0.24},"has_zh":true},"methods":[{"_id":"6a5dc9baf1c10c8ce825dcaa","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36 °C","methodology_en":"Total viable count at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":0,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","methodology_zh":"36 °C 微生物总数"},{"_id":"6a5dc9baf1c10c8ce825dcab","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22 °C","methodology_en":"Total viable count at 22 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 22 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda, woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 22 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":1,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"水、生活饮用水 22 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水、生活饮用水","methodology_zh":"22 °C 微生物总数"},{"_id":"6a5dc9baf1c10c8ce825dcac","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba enterokoków kałowych","methodology_en":"Intestinal enterococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":2,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","methodology_zh":"粪肠球菌计数","search_zh":"水、生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcad","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba gronkowców koagulazo-dodatnich","methodology_en":"Coagulase-positive staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej","reference":"PN-Z-11001-3:2000 (zał. A)","norm_bases":["PN-Z-11001-3:2000 (zał. A)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 (zał. A) Woda, woda do spozycia przez ludzi Liczba gronkowcow koagulazo-dodatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 (zal. A)","categories":["water"],"row_index":3,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000 (zał. A)","search_zh":"水、生活饮用水 凝固酶阳性葡萄球菌计数 膜过滤法 PN-Z-11001-3:2000 (zał. A)","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a5dc9baf1c10c8ce825dcae","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba bakterii grupy coli","methodology_en":"Coliform bacteria count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":4,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠菌群计数","search_zh":"水、生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcaf","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda, woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":5,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水、生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcb0","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":6,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"水、生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcb1","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36 °C","methodology_en":"Total viable count at 36 °C","parameters":[],"parameters_en":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"technique_en":"Plate method (pour plate)","computed":[],"computed_en":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w temperaturze 36 °C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w temperaturze 36 °C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":7,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Total viable count at 36 °C Plate method (pour plate) PN-EN ISO 6222:2004","search_zh":"游泳池水 36 °C 微生物总数 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"游泳池水","methodology_zh":"36 °C 微生物总数"},{"_id":"6a5dc9baf1c10c8ce825dcb2","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba gronkowców koagulazo-dodatnich","methodology_en":"Coagulase-positive staphylococci count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej","reference":"PN-Z-11001-3:2000 (zał. A)","norm_bases":["PN-Z-11001-3:2000 (zał. A)"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba gronkowców koagulazo-dodatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 (zał. A) Woda na plywalniach Liczba gronkowcow koagulazo-dodatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 (zal. A)","categories":["water"],"row_index":8,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000 (zał. A)","search_zh":"游泳池水 凝固酶阳性葡萄球菌计数 膜过滤法 PN-Z-11001-3:2000 (zał. A)","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a5dc9baf1c10c8ce825dcb3","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Escherichia coli","methodology_en":"Escherichia coli count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":9,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9baf1c10c8ce825dcb4","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Liczba Pseudomonas aeruginosa","methodology_en":"Pseudomonas aeruginosa count","parameters":[],"parameters_en":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"technique_en":"Membrane filtration method","computed":[],"computed_en":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":10,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水"},{"_id":"6a5dc9baf1c10c8ce825dcb5","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,1 – 1,0) mg/l"},{"name":"Stężenie azotu amonowego"},{"name":"Zakres","range":"(0,04 – 0,8) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 1,0) mg/l"},{"name":"Ammonium nitrogen concentration"},{"name":"Range","range":"(0,04 – 0,8) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres:\nZakres (0,1 – 1,0) mg/l\nStężenie azotu amonowego\nZakres (0,04 – 0,8) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres:\nZakres (0,1 – 1,0) mg/l\nStężenie azotu amonowego\nZakres (0,04 – 0,8) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres:\nZakres (0,1 – 1,0) mg/l\nStezenie azotu amonowego\nZakres (0,04 – 0,8) mg/l\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":11,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Range Ammonium nitrogen concentration Range PN-C-04576-4:1994","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 1,0) mg/l"},{"name":"氨氮浓度"},{"name":"范围","range":"(0,04 – 0,8) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 氨氮浓度 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcb6","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotynów","methodology_en":"Nitrite concentration","parameters":[{"name":"Zakres","range":"(0,01 – 0,8) mg/l NO2-"}],"parameters_en":[{"name":"Range","range":"(0,01 – 0,8) mg/l NO2-"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotynów\nZakres (0,01 – 0,8) mg/l NO2-\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,01 – 0,8) mg/l NO2-\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda, woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,01 – 0,8) mg/l NO2-\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":12,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,01 – 0,8) mg/l NO2-"}],"search_zh":"水、生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcb7","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,1 – 100) mg/l"},{"name":"Stężenie azotu azotanowego"},{"name":"Zakres","range":"(0,02 – 22,5) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 100) mg/l"},{"name":"Nitrate nitrogen concentration"},{"name":"Range","range":"(0,02 – 22,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres:\nZakres (0,1 – 100) mg/l\nStężenie azotu azotanowego\nZakres (0,02 – 22,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie azotanów\nZakres:\nZakres (0,1 – 100) mg/l\nStężenie azotu azotanowego\nZakres (0,02 – 22,5) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, woda do spozycia przez ludzi Stezenie azotanow\nZakres:\nZakres (0,1 – 100) mg/l\nStezenie azotu azotanowego\nZakres (0,02 – 22,5) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":13,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Nitrate concentration Spectrophotometric method Range Nitrate nitrogen concentration Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 100) mg/l"},{"name":"硝态氮浓度"},{"name":"范围","range":"(0,02 – 22,5) mg/l"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 硝态氮浓度 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcb8","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda, woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":14,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"水、生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcb9","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Przewodność elektryczna właściwa","methodology_en":"Electrical conductivity","parameters":[{"name":"Zakres","range":"(50 – 3000) μS/cm"}],"parameters_en":[{"name":"Range","range":"(50 – 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"technique_en":"Conductometric method","computed":[],"computed_en":[],"activity":"Przewodność elektryczna właściwa\nZakres (50 – 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (50 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda, woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (50 – 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":15,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(50 – 3000) μS/cm"}],"search_zh":"水、生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcba","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie żelaza ogólnego","methodology_en":"Total iron concentration","parameters":[{"name":"Zakres","range":"(30 – 10000) μg/l"}],"parameters_en":[{"name":"Range","range":"(30 – 10000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie żelaza ogólnego\nZakres (30 – 10000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (30 – 10000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda, woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (30 – 10000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":16,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(30 – 10000) μg/l"}],"search_zh":"水、生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcbb","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie manganu","methodology_en":"Manganese concentration","parameters":[{"name":"Zakres","range":"(0,010 – 0,40) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,010 – 0,40) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie manganu\nZakres (0,010 – 0,40) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie manganu\nZakres (0,010 – 0,40) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda, woda do spozycia przez ludzi Stezenie manganu\nZakres (0,010 – 0,40) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":17,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590/03","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,010 – 0,40) mg/l"}],"search_zh":"水、生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcbc","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie chlorków","methodology_en":"Chloride concentration","parameters":[{"name":"Zakres","range":"(5,0 – 400) mg/l"}],"parameters_en":[{"name":"Range","range":"(5,0 – 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda, woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 – 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":18,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 400) mg/l"}],"search_zh":"水、生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcbd","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters":[{"name":"Zakres","range":"(4,0 – 500) mg/l CaCO3"}],"parameters_en":[{"name":"Range","range":"(4,0 – 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (4,0 – 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (4,0 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda, woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (4,0 – 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":19,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(4,0 – 500) mg/l CaCO3"}],"search_zh":"水、生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcbe","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie magnezu (z obliczeń)","methodology_en":"Magnesium concentration (calculated)","parameters":[],"parameters_en":[],"technique":null,"techniques":[],"technique_en":null,"computed":[],"computed_en":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 zał. A","norm_bases":["PN-C-04554-4:1999 zał. A"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 zał. A Woda, woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999 zal. A","categories":["water"],"row_index":20,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 zał. A","search_zh":"水、生活饮用水 镁浓度（计算值） PN-C-04554-4:1999 zał. A","test_object_zh":"水、生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a5dc9baf1c10c8ce825dcbf","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie wapnia","methodology_en":"Calcium concentration","parameters":[{"name":"Zakres","range":"(2,0 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(2,0 – 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Stężenie wapnia\nZakres (2,0 – 100) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie wapnia\nZakres (2,0 – 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda, woda do spozycia przez ludzi Stezenie wapnia\nZakres (2,0 – 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":21,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","parameters_zh":[{"name":"范围","range":"(2,0 – 100) mg/l"}],"search_zh":"水、生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"水、生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a5dc9baf1c10c8ce825dcc0","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie fluorków","methodology_en":"Fluoride concentration","parameters":[{"name":"Zakres","range":"(0,15 – 1,6) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,15 – 1,6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie fluorków\nZakres (0,15 – 1,6) mg/l\nMetoda spektrofotometryczna","reference":"PN-75/C-04588.01","norm_bases":["PN-75/C-04588.01"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie fluorków\nZakres (0,15 – 1,6) mg/l\nMetoda spektrofotometryczna PN-75/C-04588.01 Woda, woda do spozycia przez ludzi Stezenie fluorkow\nZakres (0,15 – 1,6) mg/l\nMetoda spektrofotometryczna PN-75/C-04588.01","categories":["water"],"row_index":22,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Fluoride concentration Spectrophotometric method Range PN-75/C-04588.01","parameters_zh":[{"name":"范围","range":"(0,15 – 1,6) mg/l"}],"search_zh":"水、生活饮用水 氟化物浓度 分光光度法 范围 PN-75/C-04588.01","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"氟化物浓度"},{"_id":"6a5dc9baf1c10c8ce825dcc1","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie chloru wolnego i ogólnego","methodology_en":"Free and total chlorine concentration","parameters":[{"name":"Zakres","range":"(0,03 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,03 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego i ogólnego\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2011","norm_bases":["PN-EN ISO 7393-2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie chloru wolnego i ogólnego\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2011 Woda, woda do spozycia przez ludzi Stezenie chloru wolnego i ogolnego\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2011","categories":["water"],"row_index":23,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Free and total chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2011","parameters_zh":[{"name":"范围","range":"(0,03 – 2,0) mg/l"}],"search_zh":"水、生活饮用水 游离氯与总氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2011","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水","methodology_zh":"游离氯与总氯浓度"},{"_id":"6a5dc9baf1c10c8ce825dcc2","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie siarczanów","methodology_en":"Sulfate concentration","parameters":[{"name":"Zakres","range":"(1,0 – 300) mg/l"}],"parameters_en":[{"name":"Range","range":"(1,0 – 300) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"technique_en":"Turbidimetric method","computed":[],"computed_en":[],"activity":"Stężenie siarczanów\nZakres (1,0 – 300) mg/l\nMetoda turbidymetryczna","reference":"PN-79/C-04566.10","norm_bases":["PN-79/C-04566.10"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie siarczanów\nZakres (1,0 – 300) mg/l\nMetoda turbidymetryczna PN-79/C-04566.10 Woda, woda do spozycia przez ludzi Stezenie siarczanow\nZakres (1,0 – 300) mg/l\nMetoda turbidymetryczna PN-79/C-04566.10","categories":["water"],"row_index":24,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Sulfate concentration Turbidimetric method Range PN-79/C-04566.10","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,0 – 300) mg/l"}],"search_zh":"水、生活饮用水 硫酸盐浓度 浊度法 范围 PN-79/C-04566.10","test_object_zh":"水、生活饮用水","technique_zh":"浊度法"},{"_id":"6a5dc9baf1c10c8ce825dcc3","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,50 – 10) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,50 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda, woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":25,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10) mg/l O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcc4","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20 – 20) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20 – 20) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Mętność\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, woda do spozycia przez ludzi Metnosc\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":26,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 20) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcc5","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Barwa","methodology_en":"Colour","parameters":[{"name":"Zakres","range":"(5 – 30) mg/l Pt"}],"parameters_en":[{"name":"Range","range":"(5 – 30) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"technique_en":"Visual method","computed":[],"computed_en":[],"activity":"Barwa\nZakres (5 – 30) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 Metoda D","norm_bases":["PN-EN ISO 7887:2012 Metoda D"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Barwa\nZakres (5 – 30) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 Metoda D Woda, woda do spozycia przez ludzi Barwa\nZakres (5 – 30) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012 Metoda D","categories":["water"],"row_index":27,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Colour Visual method Range PN-EN ISO 7887:2012 Metoda D","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 – 30) mg/l Pt"}],"search_zh":"水、生活饮用水 色度 目视法 范围 PN-EN ISO 7887:2012 Metoda D","technique_zh":"目视法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcc6","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda, woda do spożycia przez ludzi","test_object_en":"Water, water intended for human consumption","methodology":"Stężenie jonu amonowego","methodology_en":"Ammonium ion concentration","parameters":[{"name":"Zakres","range":"(0,02 – 1,0) mg/l"},{"name":"Stężenie azotu amonowego"},{"name":"Zakres","range":"(0,02 – 0,8) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,02 – 1,0) mg/l"},{"name":"Ammonium nitrogen concentration"},{"name":"Range","range":"(0,02 – 0,8) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie jonu amonowego\nZakres:\nZakres (0,02 – 1,0) mg/l\nStężenie azotu amonowego\nZakres (0,02 – 0,8) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda, woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres:\nZakres (0,02 – 1,0) mg/l\nStężenie azotu amonowego\nZakres (0,02 – 0,8) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda, woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres:\nZakres (0,02 – 1,0) mg/l\nStezenie azotu amonowego\nZakres (0,02 – 0,8) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":28,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Water, water intended for human consumption Ammonium ion concentration Spectrophotometric method Range Ammonium nitrogen concentration Range PN-ISO 7150-1:2002","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 1,0) mg/l"},{"name":"氨氮浓度"},{"name":"范围","range":"(0,02 – 0,8) mg/l"}],"search_zh":"水、生活饮用水 铵离子浓度 分光光度法 范围 氨氮浓度 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a5dc9baf1c10c8ce825dcc7","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"pH","methodology_en":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"technique_en":"Potentiometric method","computed":[],"computed_en":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda na plywalniach pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":29,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water pH Potentiometric method Range PN-EN ISO 10523:2012","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"游泳池水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a5dc9baf1c10c8ce825dcc8","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Indeks nadmanganianowy","methodology_en":"Permanganate index","parameters":[{"name":"Zakres","range":"(0,50 – 10) mg/l O2"}],"parameters_en":[{"name":"Range","range":"(0,50 – 10) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"technique_en":"Titrimetric method","computed":[],"computed_en":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda na plywalniach Indeks nadmanganianowy\nZakres (0,50 – 10) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":30,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 10) mg/l O2"}],"search_zh":"游泳池水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"游泳池水"},{"_id":"6a5dc9baf1c10c8ce825dcc9","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Mętność","methodology_en":"Turbidity","parameters":[{"name":"Zakres","range":"(0,20 – 20) NTU"}],"parameters_en":[{"name":"Range","range":"(0,20 – 20) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"technique_en":"Nephelometric method","computed":[],"computed_en":[],"activity":"Mętność\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Mętność\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda na plywalniach Metnosc\nZakres (0,20 – 20) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":31,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 – 20) NTU"}],"search_zh":"游泳池水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"游泳池水"},{"_id":"6a5dc9baf1c10c8ce825dcca","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie azotanów","methodology_en":"Nitrate concentration","parameters":[{"name":"Zakres","range":"(0,1 – 100) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,1 – 100) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie azotanów\nZakres (0,1 – 100) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie azotanów\nZakres (0,1 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda na plywalniach Stezenie azotanow\nZakres (0,1 – 100) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":32,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,1 – 100) mg/l"}],"search_zh":"游泳池水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"游泳池水"},{"_id":"6a5dc9baf1c10c8ce825dccb","lab_id":"69ad52a3de79e566650fb356","country":"PL","accr_number":"AB 650","accr_body":"PCA","test_object":"Woda na pływalniach","test_object_en":"Swimming pool water","methodology":"Stężenie chloru wolnego i ogólnego","methodology_en":"Free and total chlorine concentration","parameters":[{"name":"Zakres","range":"(0,03 – 2,0) mg/l"}],"parameters_en":[{"name":"Range","range":"(0,03 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"technique_en":"Spectrophotometric method","computed":[],"computed_en":[],"activity":"Stężenie chloru wolnego i ogólnego\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7393-2:2011","norm_bases":["PN-EN ISO 7393-2:2011"],"lab_section":null,"lab_section_en":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"search_text":"Woda na pływalniach Stężenie chloru wolnego i ogólnego\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2011 Woda na plywalniach Stezenie chloru wolnego i ogolnego\nZakres (0,03 – 2,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 7393-2:2011","categories":["water"],"row_index":33,"parse_version":3,"parse_source":"script-pdfplumber","search_en":"Swimming pool water Free and total chlorine concentration Spectrophotometric method Range PN-EN ISO 7393-2:2011","parameters_zh":[{"name":"范围","range":"(0,03 – 2,0) mg/l"}],"search_zh":"游泳池水 游离氯与总氯浓度 分光光度法 范围 PN-EN ISO 7393-2:2011","technique_zh":"分光光度法","test_object_zh":"游泳池水","methodology_zh":"游离氯与总氯浓度"}],"has_pdf":true}