🇵🇱 „ECOLABAD” LABORATORIUM FIZYKO-CHEMICZNE PL

PCA AB 647 • Łódź, Poland • 107 methods

Environment

„ECOLABAD” LABORATORIUM FIZYKO-CHEMICZNE is a laboratory accredited by PCA under number AB 647 (Łódź, Poland). Its accreditation scope covers 107 test methods in the following areas: Environment. Test objects include: Workplace environment - air - air samples collected on activated ca…, Workplace environment - air - air samples collected on filters, Workplace environment - air - air samples collected into absorbing…, Workplace environment - air. Most frequently used techniques: Gas chromatography with flame ionization detection (GC-FID), Spectrophotometric method, Flame atomic absorption spectrometry (FAAS).

At a glance

  • Accreditation number: PCA AB 647
  • Methods in scope: 107
  • Types of test objects: 15
  • Techniques used: 10
  • City: Łódź, Poland
Accreditation number
AB 647
Accreditation body
PCA
Address
BADANIA I ANALIZY ŚRODOWISKA Sp. z o.o., ul. Henryka Wieniawskiego 40, 93-564 Łódź
City
Łódź, Poland

What this laboratory tests (15)

Analytical techniques used (10)

Laboratory locations

Accreditation scope — test methods (107)

No. Test object Methodology / Parameters Technique Reference document
„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.
1 Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level
Range (35,0 - 135,0) dB C-weighted peak sound pressure level Range (58,0 - 138,0) dB
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11
2 Workplace environment - noise Noise exposure level referred to:
an 8-hour daily working time the average weekly working time (calculated)
PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11
3 Workplace environment - indoor electric lighting Illuminance
Range (1 - 10 000) lx
Direct measurement method PB-06 wydanie 3 z dnia 02.06.2025 r.
4 Workplace environment - indoor electric lighting Illuminance uniformity (calculated) PB-06 wydanie 3 z dnia 02.06.2025 r.
5 Workplace environment - emergency lighting Illuminance
Range (0,5 - 3000) lx
Direct measurement method PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5
6 Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5
7 Workplace environment - emergency lighting Closing time
Range (5 - 70) s
Direct measurement method PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5
8 Workplace environment - emergency lighting Minimum duration of lighting operation
Range (5 - 3600) s
Direct measurement method PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5
9 Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration
Range (0,03 - 27,0) m/s2
Direct measurement method PN-EN 14253+A1:2011
10 Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
11 Workplace environment - hand-arm vibration Root-mean-square frequency-weighted vibration accelerations
Range (0,2 - 50) m/s2
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015
12 Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015
13 Workplace environment - hot microclimate Air temperature
Range (20,0 - 60,0) °C Natural wet bulb temperature Range (10,0 - 60,0) °C Black globe temperature Range (20,0 - 60,0) °C Air velocity Range (0,15 - 2,0) m/s
Direct measurement method PN-EN ISO 7243:2018-01 +Ap2:2020-04
14 Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) PN-EN ISO 7243:2018-01 +Ap2:2020-04
15 Workplace environment - cold microclimate Air temperature
Range (-30,0 - 10,0) °C Black globe temperature Range (-30,0 - 10,0) °C Air humidity Range (20,0 - 90,0) % Air velocity Range (0,15 - 2,0) m/s
Direct measurement method PN-EN ISO 11079:2008
16 Workplace environment - cold microclimate IREQmin index, IREQneutral index, twc index (calculated) PN-EN ISO 11079:2008
17 Workplace environment - moderate microclimate Air temperature
Range (5,0 - 60,0) °C Black globe temperature Range (5,0 - 60,0) °C Humidity Range (20,0 - 90,0) % Air velocity Range (0,15 - 2,0) m/s
Direct measurement method PN-EN ISO 7730:2006+Ap2:2016-04
18 Workplace environment - moderate microclimate PMV index, PPD index (calculated) PN-EN ISO 7730:2006+Ap2:2016-04
19 Workplace environment - air Sampling for the assessment of occupational exposure to:
dust agents inhalable fraction respirable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction organic substances, including inhalable fraction metals and their compounds, including inhalable fraction respirable fraction asbestos respirable fibres refractory ceramic fibres, refractory ceramic fibres mixed with other man-made mineral fibres man-made mineral fibres, excluding refractory ceramic fibres respirable fibres
Personal dosimetry method PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004
20 Workplace environment - air Sampling for the assessment of occupational exposure to:
inorganic substances, including inhalable fraction organic substances, including inhalable fraction
Stationary method PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004
21 Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004
22 Workplace environment - air Concentration of harmful dust agents – inhalable fraction
Range (0,09 - 20,4) mg/m3
Gravimetric method PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08
23 Workplace environment - air Concentration of harmful dust agents – respirable fraction
Range (0,07 - 9,3) mg/m3
Gravimetric method PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08
24 Workplace environment - air - air samples collected into absorbing solution Ammonia concentration/content
Range (0,08 - 56) mg/m3 Range (14 - 420) μg w próbce
Spectrophotometric method PN-71/Z-04041
25 Workplace environment - air - air samples collected into absorbing solution Chlorine concentration/content
Range (0,002 - 3) mg/m3 Range (0,4 - 540) μg w próbce
Spectrophotometric method PN-75/Z-04037/03
26 Workplace environment - air - air samples collected into absorbing solution Concentration/content of hydrogen cyanide
Range (0,075 - 5) mg/m3 Range (0,066 - 4,5) ppm Range (0,3 - 20,0) μg w próbce
Spectrophotometric method PN-70/Z-04053
27 Workplace environment - air - air samples collected into absorbing solution Sulphur dioxide concentration/content
Range (0,009 - 10) mg/m3 Range (0,0033 - 3,77) ppm Range (3,2 - 3600) μg w próbce
Spectrophotometric method PN-Z-04015-12:1996 | PN-Z-04015-12:1996+Ap1:2001
28 Workplace environment - air - air samples collected into absorbing solution Carbon monoxide concentration
Range (2,1 - 239) mg/m3 Range (1,8 - 206) ppm
Electrochemical method PB-05 wydanie 1 z dnia 01.12.2008 r.
29 Workplace environment - air - air samples collected into absorbing solution Exposure indices (calculated) PB-05 wydanie 1 z dnia 01.12.2008 r.
30 Workplace environment - air - air samples collected into absorbing solution Concentration/content of formaldehyde and acrolein
Formaldehyde (0,002 - 2) mg/m3 Range (0,3 - 360) μg w próbce Acrylaldehyde (Acrolein) (0,002 - 0,2) mg/m3 (0,00086 - 0,086) ppm (0,3 - 36) μg in the sample
Spectrophotometric method PB-02 wydanie 2 z dnia 01.08.2006 r.
31 Workplace environment - air - air samples collected into absorbing solution Formaldehyde concentration/content
Range (0,011 - 10,7) mg/m3 Range (1,0 - 80) μg w próbce
Spectrophotometric method PN-76/Z-04045/02
32 Workplace environment - air - air samples collected into absorbing solution Concentration/content of phosphoric(V) acid and tetraphosphorus decaoxide
Range (0,008 - 4) mg/m3 Range (1,4 - 720) μg w próbce
Spectrophotometric method PN-Z-04073-1:2014-08
33 Workplace environment - air - air samples collected into absorbing solution Iodine concentration/content
Range (0,05 - 2) mg/m3 Range (8,0 - 360) μg w próbce
Spectrophotometric method PN-Z-04433:2011
34 Workplace environment - air - air samples collected into absorbing solution Formic acid concentration/content
Range (0,08 - 30) mg/m3 Range (20 - 7200) μg w próbce
Spectrophotometric method PN-88/Z-04196/02
35 Workplace environment - air - air samples collected into absorbing solution Hydrogen peroxide concentration/content
Range (0,04 - 2,1) mg/m3 Range (0,4 - 9,6) μg w próbce
Spectrophotometric method PN-Z-04548:2023-03
36 Workplace environment - air - air samples collected into absorbing solution Ozone concentration/content
Range (0,015 - 0,3) mg/m3 Range (1,05 - 21) μg w próbce
Spectrophotometric method PN-Z-04007-2:1994
37 Workplace environment - air - air samples collected into absorbing solution Hydrogen sulphide concentration/content
Range (0,05 - 40) mg/m3 Range (18 - 14400) μg w próbce
Spectrophotometric method PN-Z-04015-13:1996
38 Workplace environment - air - air samples collected into absorbing solution Concentration/content of nitrogen monoxide and nitrogen dioxide
nitrogen oxide (0,22 - 23,1) mg/m3 Range (0,176 - 18,55) ppm Range (1,3 - 104) μg w próbce nitrogen dioxide (0,067 - 7,11) mg/m3 (0,035 - 3,72) ppm (0,4 - 16) μg in the sample
Spectrophotometric method PN-Z-04009-11:2008
39 Workplace environment - air - air samples collected into absorbing solution Potassium hydroxide concentration/content
Range (0,02 - 2,3) mg/m3 Range (7,3 - 810) μg w próbce
Spectrophotometric method PN-87/Z-04005/03
40 Workplace environment - air - air samples collected into absorbing solution Sodium hydroxide concentration/content
Range (0,011 - 2,0) mg/m3 Range (4,3 - 709) μg w próbce
Spectrophotometric method PN-84/Z-04005/02
41 Workplace environment - air - air samples collected on filters Concentration/content of methylenebis (phenyl isocyanate)
Range (0,0017 - 0,83) mg/m3 Range (0,62 - 12,5) μg w próbce
Spectrophotometric method PN-81/Z-04131/02
42 Workplace environment - air - air samples collected on filters Concentration/content of barium
Range (0,07 - 1,8) mg/m3 Range (53 - 1282) μg w próbce
Spectrophotometric method PN-82/Z-04024/02
43 Workplace environment - air - air samples collected on filters Concentration/content of ammonium chloride – vapours and inhalable fraction
Range (0,12 - 40) mg/m3 Range (86 - 28800) μg w próbce
Spectrophotometric method PN-Z-04265:2000
44 Workplace environment - air - air samples collected on filters Concentration/content of chromates (VI) and dichromates (VI) (chromates) (calculated as Cr (VI)
Range (0,006 - 0,6) mg/m3 Range (3,9 - 432) μg w próbce
Spectrophotometric method PN-87/Z-04126/03
45 Workplace environment - air - air samples collected on filters Concentration/content of chromium (VI) compounds - calculated as Cr (VI)
Range (0,00028 - 0,02) mg/m3 Range (0,192 - 13,4) μg w próbce
Spectrophotometric method NIOSH 7600:2015
46 Workplace environment - air - air samples collected on filters Concentration/content of metallic chromium, chromium compounds: chromium(II), chromium (III),chromium (VI) calculated as Cr.
Range (0,029 - 1,17) mg/m3 Range (20,0 - 800) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04434:2011
47 Workplace environment - air - air samples collected on filters Concentration of metallic chromium, chromium compounds: chromium (II) - calculated as Cr (II), chromium III – calculated as Cr (III) (calculated) PB-03 wydanie 1 z dnia 01.04.2021 r.
48 Workplace environment - air - air samples collected on filters Concentration/content of tin and its inorganic compounds, except stannane – calculated as Sn
inhalable fraction Range (0,17 - 4,2) mg/m3 Range (125 - 3024) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04488:2017-10
49 Workplace environment - air - air samples collected on filters Concentration/content of zinc oxide calculated as Zn
inhalable fraction Range (0,003 - 20) mg/m3 Range (2,1 - 14400) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-87/Z-04100/03
50 Workplace environment - air - air samples collected on filters Concentration/content of cadmium and its inorganic compounds – calculated as Cd
inhalable fraction respirable fraction Range (0,0001 - 0,013) mg/m3 Range (0,15 - 15,0) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04102-3:2013
51 Workplace environment - air - air samples collected on filters Concentration/content of cobalt and its inorganic compounds – calculated as Co
Range (0,002 - 0,4) mg/m3 Range (1,0 - 288) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04291:2003
52 Workplace environment - air - air samples collected on filters Concentration/content of manganese and its inorganic compounds - calculated as Mn
inhalable fraction respirable fraction Range (0,005 - 0,6) mg/m3 Range (3,6 - 432) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04472:2015-10+Ap1:2015-12
53 Workplace environment - air - air samples collected on filters Concentration/content of copper and its inorganic compounds – calculated as Cu
Range (0,007 - 0,6) mg/m3 Range (5 - 432) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04106-3:2002
54 Workplace environment - air - air samples collected on filters Metallic nickel concentration/content
Range (0,015 - 0,58) mg/m3 Range (10,47 - 418,8) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04502:2019-10
55 Workplace environment - air - air samples collected on filters Concentration/content of nickel compounds – calculated as Ni
inhalable fraction Range (0,0013 - 0,13) mg/m3 Range (0,96 - 96,0) μg w próbce respirable fraction Range (0,00089 - 0,089) mg/m3 Range (0,96 - 96,0) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04502:2019-10 Podstawy i Metody Oceny Środowiska Pracy 2021, 4 (110), str. 179 - 189
56 Workplace environment - air - air samples collected on filters Concentration/content of lead and its inorganic compounds – calculated as Pb
inhalable fraction Range (0,0035 - 0,142) mg/m3 Range (2,6 - 102) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04487:2017-10
57 Workplace environment - air - air samples collected on filters Silver concentration/content. Soluble silver compounds calculated as Ag
Range (0,0010 - 0,12) mg/m3 Range (0,75 - 86,40) μg w próbce
Flame atomic absorption spectrometry (FAAS) Podstawy i Metody Oceny Środowiska Pracy 1998, Zeszyt nr 19
58 Workplace environment - air - air samples collected on filters Concentration/content of silver – inhalable fraction, insoluble silver compounds – calculated as Ag
Range (0,003 - 0,1) mg/m3 Range (2,0 - 72,0) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04216-2:2012
59 Workplace environment - air - air samples collected on filters Concentration/content of iron oxides calculated as Fe iron(III) oxide iron(II) oxide triiron tetraoxide – inhalable fraction
Range (0,34 - 49,4) mg/m3 Range (49,4 - 7403,8) μg w próbce – respirable fraction Range (0,19 - 44,9) mg/m3 Range (49,4 - 4627,3) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04469:2025-02
60 Workplace environment - air - air samples collected on filters Sodium hydroxide concentration/content
Range (0,012 - 2) mg/m3 Range (4,5 - 720) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04435:2011
61 Workplace environment - air - air samples collected on filters Potassium hydroxide concentration/content
Range (0,02 - 7) mg/m3 Range (14 - 215) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04436:2011
62 Workplace environment - air - air samples collected on filters Concentration/content of calcium hydroxide
inhalable fraction respirable fraction Range (0,06 - 12) mg/m3 Range (46 - 2958) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04497:2018-09
63 Workplace environment - air - air samples collected on filters Calcium oxide concentration/content
inhalable fraction Range (0,1 - 119,7) mg/m3 Range (71,8 - 3590,9) μg w próbce respirable fraction Range (0,091 - 108,8) mg/m3 Range (71,8 - 3590,9) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04442:2023-05
64 Workplace environment - air - air samples collected on filters Concentration/content of calcium carbonate
inhalable fraction Range (0,67 - 20,15) mg/m3 Range (498 - 14940) μg w próbce
Flame atomic absorption spectrometry (FAAS) PN-Z-04294:2001
65 Workplace environment - air - air samples collected on filters Concentration/content of highly refined mineral oil – excluding metalworking fluids – inhalable fraction
Range (0,3 - 20) mg/m3 Range (0,2 - 14,4) mg w próbce
Fourier transform infrared spectrometry (FT- IR) PN-Z-04108-5:2006
66 Workplace environment - air - air samples collected on filters Concentration/content of crystalline silica (quartz and cristobalite)
respirable fraction Range (0,005 - 0,73) mg/m3 Range (5,0 - 500) μg w próbce
Fourier transform infrared spectrometry (FT- IR) Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130
67 Workplace environment - air - air samples collected on filters Hydrogen chloride concentration/content
Range (0,39 - 137) mg/m3 Range (154 - 4110) μg w próbce
Turbidimetric method PN-Z-04450:2014-08
68 Workplace environment - air - air samples collected on activated carbon tubes Acetone concentration/content
Range (48 - 3600) mg/m3 Range (0,15 - 3,95) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
69 Workplace environment - air - air samples collected on activated carbon tubes Benzene concentration/content
Range (0,063 - 3,05) mg/m3 Range (0,019 - 0,94) ppm Range (0,0006 - 0,029) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04016-10:2005
70 Workplace environment - air - air samples collected on activated carbon tubes Extraction naphtha concentration/content
Range (36 - 3000) mg/m3 Range (0,2 - 19,7) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-81/Z-04134/02
71 Workplace environment - air - air samples collected on activated carbon tubes White spirit concentration/content
Range (24 - 1800) mg/m3 Range (0,36 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-81/Z-04134/03
72 Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of 2-bromo-2-chloro-1,1,1-trifluoroethane (halothane)
Range (0,5 - 200) mg/m3 Range (0,009 - 2,0) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-92/Z-04223/02
73 Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of butan-1-ol (n-butyl alcohol)
Range (4,5 - 300) mg/m3 Range (0,078 - 1,95) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
74 Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of butan-2-one
Range (44 - 900) mg/m3 Range (0,49 - 9,8) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-79/Z-04107/02
75 Workplace environment - air - air samples collected on activated carbon tubes 2-butoxyethanol concentration/content
Range (8,3 - 400) mg/m3 Range (0,15 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
76 Workplace environment - air - air samples collected on activated carbon tubes Cyclohexane concentration/content
Range (30 - 2000) mg/m3 Range (0,38 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-86/Z-04151/02
77 Workplace environment - air - air samples collected on activated carbon tubes Cyclohexanone concentration/content
Range (4 - 160) mg/m3 Range (0,045 - 2,25) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2007, Zeszyt nr 51
78 Workplace environment - air - air samples collected on activated carbon tubes Dichloromethane concentration/content
Range (6,6 - 746) mg/m3 Range (1,87 - 211,7) ppm Range (0,065 - 4,7) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04325:2006
79 Workplace environment - air - air samples collected on activated carbon tubes Ethanol concentration/content
Range (114 - 3800) mg/m3 Range (0,38 - 11,8) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02
80 Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of diethyl ether
Range (26 - 3000) mg/m3 Range (0,35 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-86/Z-04158/02
81 Workplace environment - air - air samples collected on activated carbon tubes Ethylbenzene concentration/content
Range (8,4 - 700) mg/m3 Range (0,27 - 9,10) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-79/Z-04081/01
82 Workplace environment - air - air samples collected on activated carbon tubes Ethylene glycol concentration/content
Range (1,3 - 100) mg/m3 Range (0,11 - 8) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-88/Z-04203/02
83 Workplace environment - air - air samples collected on activated carbon tubes Isoflurane concentration/content
Range (0,78 - 64) mg/m3 Range (0,056 - 1,2) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04423:2001
84 Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of xylene –
mixture of isomers 1,2-; 1,3-; 1,4- Range (8,5 - 200) mg/m3 Range (0,09 - 17) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-89/Z-04023/02 | PB-14 wydanie 3 z dnia 10.06.2016 r.
85 Workplace environment - air - air samples collected on activated carbon tubes Methanol concentration/content
Range (10 - 600) mg/m3 Range (0,15 - 3,89) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2014, Zeszyt nr 81
86 Workplace environment - air - air samples collected on activated carbon tubes 1-methoxypropan-2-ol concentration/content
Range (13 - 720) mg/m3 Range (0,22 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04354:2005
87 Workplace environment - air - air samples collected on activated carbon tubes Kerosene concentration/content
Range (7,8 - 600) mg/m3 Range (0,10 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-92/Z-04227/02
88 Workplace environment - air - air samples collected on activated carbon tubes Hexane concentration/content -
Range (6,3 - 536) mg/m3 Range (0,065 - 3,4) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04136-03:2003
89 Workplace environment - air - air samples collected on activated carbon tubes 2-butoxyethyl acetate concentration/content
Range (9,0 - 600) mg/m3 Range (0,11 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04304:2003
90 Workplace environment - air - air samples collected on activated carbon tubes Butyl acetate concentration/content
Range (16 - 1900) mg/m3 Range (0,31 - 8,6) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-78/Z-04119/01
91 Workplace environment - air - air samples collected on activated carbon tubes Ethyl acetate concentration/content
Range (17 - 1500) mg/m3 Range (4,65 - 410,3) ppm Range (1,14 - 23) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-78/Z-04119/01
92 Workplace environment - air - air samples collected on activated carbon tubes Methyl acetate concentration/content
Range (23 - 1200) mg/m3 Range (0,35 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-78/Z-04119/01
93 Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of propyl acetate
Range (19 - 2000) mg/m3 Range (0,22 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-78/Z-04119/01
94 Workplace environment - air - air samples collected on activated carbon tubes 2-methoxy-1-methylethyl acetate concentration/content
Range (20 - 520) mg/m3 Range (0,36 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04119-10:2008
95 Workplace environment - air - air samples collected on activated carbon tubes Vinyl acetate concentration/content
Range (1,0 - 60) mg/m3 Range (0,08 - 5,2) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-87/Z-04178/02
96 Workplace environment - air - air samples collected on activated carbon tubes Pentane concentration/content
Range (300 - 6000) mg/m3 Range (0,41 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04318:2005
97 Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of propan-1-ol
Range (20 - 600) mg/m3 Range (0,20 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04224-3:2003
98 Workplace environment - air - air samples collected on activated carbon tubes Propan-2-ol concentration/content
Range (49 - 1200) mg/m3 Range (1,14 - 22,7) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-92/Z-04224/02
99 Workplace environment - air - air samples collected on activated carbon tubes Styrene concentration/content
Range (3,7 - 400) mg/m3 Range (0,068 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-86/Z-04152/02
100 Workplace environment - air - air samples collected on activated carbon tubes Sevoflurane concentration/content
Range (0,29 - 110) mg/m3 Range (0,005 - 2,0) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04429:2011
101 Workplace environment - air - air samples collected on activated carbon tubes Tetrachloroethene concentration/content
Range (4,5 - 428) mg/m3 Range (0,65 - 62,2) ppm Range (0,12 - 20) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-83/Z-04118/02
102 Workplace environment - air - air samples collected on activated carbon tubes Toluene concentration/content
Range (8,3 - 700) mg/m3 Range (0,15 - 5) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-78/Z-04115/01
103 Workplace environment - air - air samples collected on silica gel tubes Acetic acid concentration/content
Range (1,3 - 60) mg/m3 Range (0,52 - 24,1) ppm Range (0,12 - 5) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PN-Z-04323:2004
104 Workplace environment - air Concentration of chemical substances -
acetone (48 - 3600) mg/m3 benzene (0,063 - 3,05) mg/m3 Range (0,019 - 0,94) ppm extraction naphtha (36 - 3000) mg/m3 white spirit (24 - 1800) mg/m3 2-bromo-2-chloro-1,1,1-trifluoroethane (halothane) (0,5 - 200) mg/m3 butan-1-ol (n-butyl alcohol) (4,5 - 300) mg/m3 butan-2-one (44 - 900) mg/m3 2-butoxyethanol (8,3 - 400) mg/m3 cyclohexane (30 - 2000) mg/m3 cyclohexanone (4 - 160) mg/m3 dichloromethane (6,6 - 746) mg/m3 (1,87 - 211,7) ppm ethanol (114 - 3800) mg/m3 diethyl ether (26 - 3000) mg/m3 ethylbenzene (8,4 - 700) mg/m3 ethylene glycol (1,3 - 100) mg/m3 isoflurane (0,78 - 64) mg/m3 acetic acid (1,3 - 60) mg/m3 (0,52 - 24,1) ppm xylene – mixture of isomers 1,2-; 1,3-; 1,4 (8,5 - 200) mg/m3 methanol (10 - 600) mg/m3 1-methoxypropan-2-ol (13 - 720) mg/m3 kerosene (7,8 - 600) mg/m3 n-hexane (6,3 - 536) mg/m3 2-butoxyethyl acetate (9,0 - 600) mg/m3 butyl acetate (16 - 1900) mg/m3 ethyl acetate (17 - 1500) mg/m3 (4,65 - 410,3) ppm methyl acetate (23 - 1200) mg/m3 propyl acetate (19 - 2000) mg/m3 2-methoxy-1-methylethyl acetate (20 - 520) mg/m3 vinyl acetate (1,0 - 60) mg/m3 pentane (300 - 6000) mg/m3 propan-1-ol (20 - 600) mg/m3 propan-2-ol (49 - 1200) mg/m3 styrene (3,7 - 400) mg/m3 sevoflurane (0,29 - 110) mg/m3 tetrachloroethene (4,5 - 428) mg/m3 (0,65 - 62,2) ppm toluene (8,3 - 700) mg/m3
Gas chromatography with flame ionization detection (GC-FID) PB-14 wydanie 3 z dnia 10.06.2016 r.
105 Workplace environment - air samples collected on activated carbon tubes Content of chemical substances
acetone (0,15 - 3,95) mg in the sample benzene (0,0006 - 0,029) mg in the sample extraction naphtha Range (0,2 - 19,7) mg w próbce white spirit (0,36 - 20) mg in the sample 2-bromo-2-chloro-1,1,1-trifluoroethane (halothane) - (0,009 - 2,0) mg in the sample butan-1-ol (n-butyl alcohol) (0,078 - 1,95) mg in the sample butan-2-one (0,49 - 9,8) mg in the sample 2-butoxyethanol (0,15 - 20) mg in the sample cyclohexane (0,38 - 20) mg in the sample cyclohexanone (0,045 - 2,25) mg in the sample dichloromethane (0,065 - 4,7) mg in the sample ethanol (0,38 - 11,8) mg in the sample diethyl ether (0,35 - 20) mg in the sample ethylbenzene (0,27 - 9,10) mg in the sample ethylene glycol (0,11 - 8,0) mg in the sample isoflurane (0,056 - 1,2) mg in the sample Xylene – mixture of isomers 1,2-; 1,3-; 1,4-(0,09 - 17) mg in the sample methanol (0,15 - 3,89) mg in the sample 1-methoxypropan-2-ol (0,22 - 20) mg in the sample kerosene (0,10 - 20) mg in the sample n-hexane (0,065 - 3,4) mg in the sample
Gas chromatography with flame ionization detection (GC-FID) PB-14 wydanie 3 z dnia 10.06.2016 r.
106 Workplace environment - air samples collected on activated carbon tubes Content of chemical substances
2-butoxyethyl acetate Range (0,11 - 20) mg w próbce butyl acetate (0,31 - 8,6) mg in sample ethyl acetate (1,14 - 23) mg in sample methyl acetate (0,35 - 20) mg in sample propyl acetate (0,22 - 20) mg in sample 2-methoxy-1-methylethyl acetate – (0,36 - 20) mg in sample vinyl acetate (0,08 - 5,2) mg in sample pentane (0,41 - 20) mg in sample propan-1-ol (0,20 - 20) mg in sample propan-2-ol (1,14 - 22,7) mg in sample sevoflurane (0,005 - 2,0) mg in sample styrene (0,068 - 20) mg in sample toluene (0,15 - 5) mg in sample tetrachloroethene (0,12 - 20) mg in sample
Gas chromatography with flame ionization detection (GC-FID) PB-14 wydanie 3 z dnia 10.06.2016 r.
107 Workplace environment - air samples collected on silica gel tubes Acetic acid content
Range (0,12 - 5) mg w próbce
Gas chromatography with flame ionization detection (GC-FID) PB-14 wydanie 3 z dnia 10.06.2016 r.

Reference standards (91)

NIOSH 7600:2015
PB-02 wydanie 2 z dnia 01.08.2006 r.
PB-03 wydanie 1 z dnia 01.04.2021 r.
PB-05 wydanie 1 z dnia 01.12.2008 r.
PB-06 wydanie 3 z dnia 02.06.2025 r.
PB-14 wydanie 3 z dnia 10.06.2016 r.
PN-70/Z-04053
PN-71/Z-04041
PN-75/Z-04037/03
PN-76/Z-04045/02
PN-78/Z-04115/01
PN-78/Z-04119/01
PN-79/Z-04081/01
PN-79/Z-04107/02
PN-81/Z-04131/02
PN-81/Z-04134/02
PN-81/Z-04134/03
PN-82/Z-04024/02
PN-83/Z-04118/02
PN-84/Z-04005/02
PN-86/Z-04151/02
PN-86/Z-04152/02
PN-86/Z-04158/02
PN-87/Z-04005/03
PN-87/Z-04100/03
PN-87/Z-04126/03
PN-87/Z-04178/02
PN-88/Z-04196/02
PN-88/Z-04203/02
PN-89/Z-04023/02
PN-92/Z-04223/02
PN-92/Z-04224/02
PN-92/Z-04227/02
PN-EN 14253+A1:2011
PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5
PN-EN ISO 11079:2008
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004
PN-EN ISO 5349-2:2004+A1:2015
PN-EN ISO 7243:2018-01 +Ap2:2020-04
PN-EN ISO 7730:2006+Ap2:2016-04
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11
PN-N-01307:1994
PN-Z-04007-2:1994
PN-Z-04008-7:2002
PN-Z-04008-7:2002+Az1:2004
PN-Z-04009-11:2008
PN-Z-04015-12:1996
PN-Z-04015-12:1996+Ap1:2001
PN-Z-04015-13:1996
PN-Z-04016-10:2005
PN-Z-04073-1:2014-08
PN-Z-04102-3:2013
PN-Z-04106-3:2002
PN-Z-04108-5:2006
PN-Z-04119-10:2008
PN-Z-04136-03:2003
PN-Z-04216-2:2012
PN-Z-04224-3:2003
PN-Z-04265:2000
PN-Z-04291:2003
PN-Z-04294:2001
PN-Z-04304:2003
PN-Z-04318:2005
PN-Z-04323:2004
PN-Z-04325:2006
PN-Z-04354:2005
PN-Z-04423:2001
PN-Z-04429:2011
PN-Z-04433:2011
PN-Z-04434:2011
PN-Z-04435:2011
PN-Z-04436:2011
PN-Z-04442:2023-05
PN-Z-04450:2014-08
PN-Z-04469:2025-02
PN-Z-04472:2015-10+Ap1:2015-12
PN-Z-04487:2017-10
PN-Z-04488:2017-10
PN-Z-04497:2018-09
PN-Z-04502:2019-10
PN-Z-04502:2019-10 Podstawy i Metody Oceny Środowiska Pracy 2021, 4 (110), str. 179 - 189
PN-Z-04507:2022-05
PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05
PN-Z-04508:2022-05/Ap1:2022-08
PN-Z-04548:2023-03
Podstawy i Metody Oceny Środowiska Pracy 1998, Zeszyt nr 19
Podstawy i Metody Oceny Środowiska Pracy 2007, Zeszyt nr 51
Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130
Podstawy i Metody Oceny Środowiska Pracy 2014, Zeszyt nr 81