{"lab":{"_id":"69ad52a3de79e566650fb350","accr_number":"AB 647","country":"PL","accr_body":"PCA","address":"BADANIA I ANALIZY ŚRODOWISKA Sp. z o.o., ul. Henryka Wieniawskiego 40, 93-564 Łódź","categories":["environment"],"city":"Łódź","imported_at":"2026-03-08T10:42:43.265Z","methods_count":107,"name":"„ECOLABAD” LABORATORIUM FIZYKO-CHEMICZNE","parse_status":"parsed","parse_version":3,"pdf_files":["AB_647.pdf"],"scope_summary":"","search_text":"„ecolabad” laboratorium fizyko-chemiczne badania i analizy środowiska sp. z o.o., ul. henryka wieniawskiego 40, 93-564 łódź environment metrology other materials automotive food petro","status":"active","updated_at":"2026-03-08T14:51:33.257Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:10:08.247Z","location":{"type":"Point","coordinates":[19.456,51.7592]},"email_confidence":"high","email_mx":true,"email_source":"https://ecolabad.pl/kontakt.html","fields_of_testing":[{"codes":"C/33/P","pl":"Badania chemiczne i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Chemical tests and sampling - working environment (harmful factors - air)"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe i uciążliwe – hałas, oświetlenie, drgania, mikroklimat)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful and nuisance factors – noise, lighting, vibration, microclimate)"},{"codes":"N/33/P","pl":"Badania właściwości fizycznych i pobieranie próbek – środowisko pracy (czynniki szkodliwe - powietrze)","en":"Tests of physical properties and sampling - working environment (harmful factors - air)"}],"issue":{"no":"24","date":"23.07.2026"},"parse_date":"2026-08-13T08:10:08.247Z","parse_source":"agent-claude-code","map_coord":[51.740338,19.44163],"map_geo":"nominatim-street","lab_locations":[{"name":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/9ddbc7bf5d501f18e257eb46c0efc020/AB%20647.pdf","has_en":true,"category_counts":{"environment":107,"materials":4,"automotive":3,"petro":3},"category_scores":{"environment":97.85,"materials":0.14,"automotive":0.08,"petro":0.08},"has_zh":true,"lab_locations_zh":[{"name":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7be00636ba417e41bfcc","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A","parameters":[{"name":"Zakres","range":"(35,0 - 135,0) dB"},{"name":"Szczytowy poziom dźwięku C"},{"name":"Zakres","range":"(58,0 - 138,0) dB"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (35,0 - 135,0) dB\nSzczytowy poziom dźwięku C\nZakres (58,0 - 138,0) dB\nMetoda pomiarowa bezpośrednia","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Równoważny poziom dźwięku A Maksymalny poziom dźwięku A\nZakres:\nZakres (35,0 - 135,0) dB\nSzczytowy poziom dźwięku C\nZakres (58,0 - 138,0) dB\nMetoda pomiarowa bezpośrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11 Srodowisko pracy - halas Rownowazny poziom dzwieku A Maksymalny poziom dzwieku A\nZakres:\nZakres (35,0 - 135,0) dB\nSzczytowy poziom dzwieku C\nZakres (58,0 - 138,0) dB\nMetoda pomiarowa bezposrednia PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 – punkt 10 i strategie 3 – punkt 11","categories":["environment"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"A-weighted equivalent sound level Maximum A-weighted sound level","parameters_en":[{"name":"Range","range":"(35,0 - 135,0) dB"},{"name":"C-weighted peak sound pressure level"},{"name":"Range","range":"(58,0 - 138,0) dB"}],"search_en":"Workplace environment - noise A-weighted equivalent sound level Maximum A-weighted sound level Direct measurement method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range C-weighted peak sound pressure level Range PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11","technique_en":"Direct measurement method","test_object_en":"Workplace environment - noise","methodology_zh":"A 计权等效声级 A 计权最大声级","parameters_zh":[{"name":"范围","range":"(35,0 - 135,0) dB"},{"name":"C 计权峰值声级"},{"name":"范围","range":"(58,0 - 138,0) dB"}],"search_zh":"工作场所环境 — 噪声 A 计权等效声级 A 计权最大声级 直接测量法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 C 计权峰值声级 范围 PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bfcd","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - hałas","methodology":"Poziom ekspozycji na hałas odniesiony do:","parameters":[{"name":"8 godzinnego dobowego wymiaru czasu pracy"},{"name":"przeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)"}],"technique":null,"techniques":[],"computed":[],"activity":"Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8 godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń)","reference":"PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11","norm_bases":["PN-N-01307:1994","PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - hałas Poziom ekspozycji na hałas odniesiony do:\nZakres:\n8 godzinnego dobowego wymiaru czasu pracy\nprzeciętnego tygodniowego wymiaru czasu pracy (z obliczeń) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11 Srodowisko pracy - halas Poziom ekspozycji na halas odniesiony do:\nZakres:\n8 godzinnego dobowego wymiaru czasu pracy\nprzecietnego tygodniowego wymiaru czasu pracy (z obliczen) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wylaczeniem metody obejmujacej strategie 2 – punkt 10 i strategie 3 – punkt 11","categories":["environment"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Noise exposure level referred to:","parameters_en":[{"name":"an 8-hour daily working time"},{"name":"the average weekly working time (calculated)"}],"search_en":"Workplace environment - noise Noise exposure level referred to: „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. an 8-hour daily working time the average weekly working time (calculated) PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11","test_object_en":"Workplace environment - noise","methodology_zh":"噪声暴露级，参照：","parameters_zh":[{"name":"8 小时日工作时间"},{"name":"平均每周工作时间（计算值）"}],"search_zh":"工作场所环境 — 噪声 噪声暴露级，参照： „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 8 小时日工作时间 平均每周工作时间（计算值） PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 – punkt 10 i strategię 3 – punkt 11","test_object_zh":"工作场所环境 — 噪声","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bfce","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(1 - 10 000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (1 - 10 000) lx\nMetoda pomiarowa bezpośrednia","reference":"PB-06 wydanie 3 z dnia 02.06.2025 r.","norm_bases":["PB-06 wydanie 3 z dnia 02.06.2025 r."],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Natężenie oświetlenia\nZakres (1 - 10 000) lx\nMetoda pomiarowa bezpośrednia PB-06 wydanie 3 z dnia 02.06.2025 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Natezenie oswietlenia\nZakres (1 - 10 000) lx\nMetoda pomiarowa bezposrednia PB-06 wydanie 3 z dnia 02.06.2025 r.","categories":["environment"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(1 - 10 000) lx"}],"search_en":"Workplace environment - indoor electric lighting Illuminance Direct measurement method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range PB-06 wydanie 3 z dnia 02.06.2025 r.","technique_en":"Direct measurement method","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(1 - 10 000) lx"}],"search_zh":"工作场所环境 — 室内电气照明 照度 直接测量法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 PB-06 wydanie 3 z dnia 02.06.2025 r.","technique_zh":"直接测量法","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bfcf","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie elektryczne we wnętrzach","methodology":"Równomierność oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Równomierność oświetlenia (z obliczeń)","reference":"PB-06 wydanie 3 z dnia 02.06.2025 r.","norm_bases":["PB-06 wydanie 3 z dnia 02.06.2025 r."],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie elektryczne we wnętrzach Równomierność oświetlenia (z obliczeń) PB-06 wydanie 3 z dnia 02.06.2025 r. Srodowisko pracy - oswietlenie elektryczne we wnetrzach Rownomiernosc oswietlenia (z obliczen) PB-06 wydanie 3 z dnia 02.06.2025 r.","categories":["environment"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Illuminance uniformity (calculated)","search_en":"Workplace environment - indoor electric lighting Illuminance uniformity (calculated) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PB-06 wydanie 3 z dnia 02.06.2025 r.","test_object_en":"Workplace environment - indoor electric lighting","methodology_zh":"照度均匀度（计算值）","search_zh":"工作场所环境 — 室内电气照明 照度均匀度（计算值） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PB-06 wydanie 3 z dnia 02.06.2025 r.","test_object_zh":"工作场所环境 — 室内电气照明","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bfd0","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Natężenie oświetlenia","parameters":[{"name":"Zakres","range":"(0,5 - 3000) lx"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie oświetlenia\nZakres (0,5 - 3000) lx\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Natężenie oświetlenia\nZakres (0,5 - 3000) lx\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5 Srodowisko pracy - oswietlenie awaryjne Natezenie oswietlenia\nZakres (0,5 - 3000) lx\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","categories":["environment"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Illuminance","parameters_en":[{"name":"Range","range":"(0,5 - 3000) lx"}],"search_en":"Workplace environment - emergency lighting Illuminance Direct measurement method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","methodology_zh":"照度","parameters_zh":[{"name":"范围","range":"(0,5 - 3000) lx"}],"search_zh":"工作场所环境 — 应急照明 照度 直接测量法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","technique_zh":"直接测量法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a7d7be00636ba417e41bfd1","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń)","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Stosunek minimalnego do maksymalnego natężenia oświetlenia (z obliczeń) PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5 Srodowisko pracy - oswietlenie awaryjne Stosunek minimalnego do maksymalnego natezenia oswietlenia (z obliczen) PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","categories":["environment"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Ratio of minimum to maximum illuminance (calculated)","search_en":"Workplace environment - emergency lighting Ratio of minimum to maximum illuminance (calculated) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","test_object_en":"Workplace environment - emergency lighting","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","search_zh":"工作场所环境 — 应急照明 最小与最大照度之比（计算值） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","methodology_zh":"最小与最大照度之比（计算值）","test_object_zh":"工作场所环境 — 应急照明"},{"_id":"6a7d7be00636ba417e41bfd2","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Czas załączania","parameters":[{"name":"Zakres","range":"(5 - 70) s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Czas załączania\nZakres (5 - 70) s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Czas załączania\nZakres (5 - 70) s\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5 Srodowisko pracy - oswietlenie awaryjne Czas zalaczania\nZakres (5 - 70) s\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","categories":["environment"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Closing time","parameters_en":[{"name":"Range","range":"(5 - 70) s"}],"search_en":"Workplace environment - emergency lighting Closing time Direct measurement method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","parameters_zh":[{"name":"范围","range":"(5 - 70) s"}],"search_zh":"工作场所环境 — 应急照明 接通时间 直接测量法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","technique_zh":"直接测量法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"接通时间"},{"_id":"6a7d7be00636ba417e41bfd3","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - oświetlenie awaryjne","methodology":"Minimalny czas stosowania oświetlenia","parameters":[{"name":"Zakres","range":"(5 - 3600) s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Minimalny czas stosowania oświetlenia\nZakres (5 - 3600) s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","norm_bases":["PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - oświetlenie awaryjne Minimalny czas stosowania oświetlenia\nZakres (5 - 3600) s\nMetoda pomiarowa bezpośrednia PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5 Srodowisko pracy - oswietlenie awaryjne Minimalny czas stosowania oswietlenia\nZakres (5 - 3600) s\nMetoda pomiarowa bezposrednia PN-EN 1838:2013-11 z wylaczeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","categories":["environment"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Minimum duration of lighting operation","parameters_en":[{"name":"Range","range":"(5 - 3600) s"}],"search_en":"Workplace environment - emergency lighting Minimum duration of lighting operation Direct measurement method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","technique_en":"Direct measurement method","test_object_en":"Workplace environment - emergency lighting","parameters_zh":[{"name":"范围","range":"(5 - 3600) s"}],"search_zh":"工作场所环境 — 应急照明 照明的最短使用时间 直接测量法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 PN-EN 1838:2013-11 z wyłączeniem pkt. 4.2.3, 4.2.4, 4.2.7, 4.3.3, 4.3.4, 4.3.7, 4.3.9, 4.4 i 5","technique_zh":"直接测量法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 应急照明","methodology_zh":"照明的最短使用时间"},{"_id":"6a7d7be00636ba417e41bfd4","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Skuteczne ważone częstotliwościowo przyspieszenie drgań","parameters":[{"name":"Zakres","range":"(0,03 - 27,0) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 - 27,0) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Skuteczne ważone częstotliwościowo przyspieszenie drgań\nZakres (0,03 - 27,0) m/s2\nMetoda pomiarowa bezpośrednia PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Skuteczne wazone czestotliwosciowo przyspieszenie drgan\nZakres (0,03 - 27,0) m/s2\nMetoda pomiarowa bezposrednia PN-EN 14253+A1:2011","categories":["environment"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Frequency-weighted r.m.s. vibration acceleration","parameters_en":[{"name":"Range","range":"(0,03 - 27,0) m/s2"}],"search_en":"Workplace environment - whole-body vibration Frequency-weighted r.m.s. vibration acceleration Direct measurement method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range PN-EN 14253+A1:2011","technique_en":"Direct measurement method","test_object_en":"Workplace environment - whole-body vibration","methodology_zh":"频率计权振动加速度有效值","parameters_zh":[{"name":"范围","range":"(0,03 - 27,0) m/s2"}],"search_zh":"工作场所环境 — 全身振动 频率计权振动加速度有效值 直接测量法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 PN-EN 14253+A1:2011","technique_zh":"直接测量法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 全身振动"},{"_id":"6a7d7be00636ba417e41bfd5","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń)","reference":"PN-EN 14253+A1:2011","norm_bases":["PN-EN 14253+A1:2011"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania o ogólnym działaniu na organizm człowieka Ekspozycja dzienna, wyrażona w postaci równoważnego energetycznie dla 8-godzin działania skutecznego, skorygowanego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci skutecznego, ważonego częstotliwościowo przyspieszenia drgań, dominującego wśród przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych z uwzględnieniem właściwych współczynników (1.4awx, 1.4awy, awz) (z obliczeń) PN-EN 14253+A1:2011 Srodowisko pracy - drgania o ogolnym dzialaniu na organizm czlowieka Ekspozycja dzienna, wyrazona w postaci rownowaznego energetycznie dla 8-godzin dzialania skutecznego, skorygowanego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci skutecznego, wazonego czestotliwosciowo przyspieszenia drgan, dominujacego wsrod przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych z uwzglednieniem wlasciwych wspolczynnikow (1.4awx, 1.4awy, awz) (z obliczen) PN-EN 14253+A1:2011","categories":["environment"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)","search_en":"Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-EN 14253+A1:2011","test_object_en":"Workplace environment - whole-body vibration","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","search_zh":"工作场所环境 — 全身振动 日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-EN 14253+A1:2011","test_object_zh":"工作场所环境 — 全身振动","methodology_zh":"日暴露量，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量并计入相应系数（1.4awx、1.4awy、awz）所确定的振动加速度中占主导的频率计权振动加速度有效值表示（计算值）"},{"_id":"6a7d7be00636ba417e41bfd6","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Skuteczne ważone częstotliwościowo przyspieszenia drgań","parameters":[{"name":"Zakres","range":"(0,2 - 50) m/s2"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Skuteczne ważone częstotliwościowo przyspieszenia drgań\nZakres (0,2 - 50) m/s2\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004+A1:2015"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Skuteczne ważone częstotliwościowo przyspieszenia drgań\nZakres (0,2 - 50) m/s2\nMetoda pomiarowa bezpośrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Skuteczne wazone czestotliwosciowo przyspieszenia drgan\nZakres (0,2 - 50) m/s2\nMetoda pomiarowa bezposrednia PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015","categories":["environment"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Root-mean-square frequency-weighted vibration accelerations","parameters_en":[{"name":"Range","range":"(0,2 - 50) m/s2"}],"search_en":"Workplace environment - hand-arm vibration Root-mean-square frequency-weighted vibration accelerations Direct measurement method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hand-arm vibration","parameters_zh":[{"name":"范围","range":"(0,2 - 50) m/s2"}],"search_zh":"工作场所环境 — 手传振动 频率计权有效振动加速度 直接测量法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015","technique_zh":"直接测量法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 手传振动","methodology_zh":"频率计权有效振动加速度"},{"_id":"6a7d7be00636ba417e41bfd7","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne","methodology":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń)","reference":"PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015","norm_bases":["PN-EN ISO 5349-1:2004","PN-EN ISO 5349-2:2004","PN-EN ISO 5349-2:2004+A1:2015"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - drgania działające na organizm człowieka przez kończyny górne Ekspozycja dzienna, wyrażona w postaci równoważnej energetycznie dla 8-godzin działania sumy wektorowej skutecznych, skorygowanych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwająca 30 minut i krócej, wyrażona w postaci sumy wektorowej skutecznych, ważonych częstotliwościowo przyspieszeń drgań, wyznaczonych dla trzech składowych kierunkowych (ahwx, ahwy, ahwz) (z obliczeń) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015 Srodowisko pracy - drgania dzialajace na organizm czlowieka przez konczyny gorne Ekspozycja dzienna, wyrazona w postaci rownowaznej energetycznie dla 8-godzin dzialania sumy wektorowej skutecznych, skorygowanych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz), Ekspozycja trwajaca 30 minut i krocej, wyrazona w postaci sumy wektorowej skutecznych, wazonych czestotliwosciowo przyspieszen drgan, wyznaczonych dla trzech skladowych kierunkowych (ahwx, ahwy, ahwz) (z obliczen) PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015","categories":["environment"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated)","search_en":"Workplace environment - hand-arm vibration Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the vector sum of the r.m.s. frequency-corrected vibration accelerations determined for three directional components (ahwx, ahwy, ahwz), Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy, ahwz) (calculated) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015","test_object_en":"Workplace environment - hand-arm vibration","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值）","search_zh":"工作场所环境 — 手传振动 日暴露量，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值矢量和的 8 小时能量等效值表示；持续 30 分钟及以下的暴露，以三个方向分量（ahwx、ahwy、ahwz）频率计权振动加速度有效值的矢量和表示（计算值） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004 | PN-EN ISO 5349-2:2004+A1:2015","test_object_zh":"工作场所环境 — 手传振动"},{"_id":"6a7d7be00636ba417e41bfd8","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(20,0 - 60,0) °C"},{"name":"Temperatura wilgotna naturalna"},{"name":"Zakres","range":"(10,0 - 60,0) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(20,0 - 60,0) °C"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 2,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (20,0 - 60,0) °C\nTemperatura wilgotna naturalna\nZakres (10,0 - 60,0) °C\nTemperatura poczernionej kuli\nZakres (20,0 - 60,0) °C\nPrędkość powietrza\nZakres (0,15 - 2,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7243:2018-01 +Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01 +Ap2:2020-04"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Temperatura powietrza\nZakres:\nZakres (20,0 - 60,0) °C\nTemperatura wilgotna naturalna\nZakres (10,0 - 60,0) °C\nTemperatura poczernionej kuli\nZakres (20,0 - 60,0) °C\nPrędkość powietrza\nZakres (0,15 - 2,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7243:2018-01 +Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Temperatura powietrza\nZakres:\nZakres (20,0 - 60,0) °C\nTemperatura wilgotna naturalna\nZakres (10,0 - 60,0) °C\nTemperatura poczernionej kuli\nZakres (20,0 - 60,0) °C\nPredkosc powietrza\nZakres (0,15 - 2,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7243:2018-01 +Ap2:2020-04","categories":["environment"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(20,0 - 60,0) °C"},{"name":"Natural wet bulb temperature"},{"name":"Range","range":"(10,0 - 60,0) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(20,0 - 60,0) °C"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 2,0) m/s"}],"search_en":"Workplace environment - hot microclimate Air temperature Direct measurement method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Natural wet bulb temperature Range Black globe temperature Range Air velocity Range PN-EN ISO 7243:2018-01 +Ap2:2020-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - hot microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(20,0 - 60,0) °C"},{"name":"自然湿球温度"},{"name":"范围","range":"(10,0 - 60,0) °C"},{"name":"黑球温度"},{"name":"范围","range":"(20,0 - 60,0) °C"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 2,0) m/s"}],"search_zh":"工作场所环境 — 高温微气候 空气温度 直接测量法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 自然湿球温度 范围 黑球温度 范围 空气流速 范围 PN-EN ISO 7243:2018-01 +Ap2:2020-04","technique_zh":"直接测量法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a7d7be00636ba417e41bfd9","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat gorący","methodology":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń)","reference":"PN-EN ISO 7243:2018-01 +Ap2:2020-04","norm_bases":["PN-EN ISO 7243:2018-01 +Ap2:2020-04"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat gorący Wskaźnik WBGT, Wskaźnik WBGTeff (z obliczeń) PN-EN ISO 7243:2018-01 +Ap2:2020-04 Srodowisko pracy - mikroklimat goracy Wskaznik WBGT, Wskaznik WBGTeff (z obliczen) PN-EN ISO 7243:2018-01 +Ap2:2020-04","categories":["environment"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"WBGT index, WBGTeff index (calculated)","search_en":"Workplace environment - hot microclimate WBGT index, WBGTeff index (calculated) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-EN ISO 7243:2018-01 +Ap2:2020-04","test_object_en":"Workplace environment - hot microclimate","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"WBGT 指数、WBGTeff 指数（计算值）","search_zh":"工作场所环境 — 高温微气候 WBGT 指数、WBGTeff 指数（计算值） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-EN ISO 7243:2018-01 +Ap2:2020-04","test_object_zh":"工作场所环境 — 高温微气候"},{"_id":"6a7d7be00636ba417e41bfda","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(-30,0 - 10,0) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(-30,0 - 10,0) °C"},{"name":"Wilgotność powietrza"},{"name":"Zakres","range":"(20,0 - 90,0) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 2,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (-30,0 - 10,0) °C\nTemperatura poczernionej kuli\nZakres (-30,0 - 10,0) °C\nWilgotność powietrza\nZakres (20,0 - 90,0) %\nPrędkość powietrza\nZakres (0,15 - 2,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30,0 - 10,0) °C\nTemperatura poczernionej kuli\nZakres (-30,0 - 10,0) °C\nWilgotność powietrza\nZakres (20,0 - 90,0) %\nPrędkość powietrza\nZakres (0,15 - 2,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Temperatura powietrza\nZakres:\nZakres (-30,0 - 10,0) °C\nTemperatura poczernionej kuli\nZakres (-30,0 - 10,0) °C\nWilgotnosc powietrza\nZakres (20,0 - 90,0) %\nPredkosc powietrza\nZakres (0,15 - 2,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 11079:2008","categories":["environment"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(-30,0 - 10,0) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(-30,0 - 10,0) °C"},{"name":"Air humidity"},{"name":"Range","range":"(20,0 - 90,0) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 2,0) m/s"}],"search_en":"Workplace environment - cold microclimate Air temperature Direct measurement method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Black globe temperature Range Air humidity Range Air velocity Range PN-EN ISO 11079:2008","technique_en":"Direct measurement method","test_object_en":"Workplace environment - cold microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(-30,0 - 10,0) °C"},{"name":"黑球温度"},{"name":"范围","range":"(-30,0 - 10,0) °C"},{"name":"空气湿度"},{"name":"范围","range":"(20,0 - 90,0) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 2,0) m/s"}],"search_zh":"工作场所环境 — 低温微气候 空气温度 直接测量法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 黑球温度 范围 空气湿度 范围 空气流速 范围 PN-EN ISO 11079:2008","technique_zh":"直接测量法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 低温微气候"},{"_id":"6a7d7be00636ba417e41bfdb","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat zimny","methodology":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń)","reference":"PN-EN ISO 11079:2008","norm_bases":["PN-EN ISO 11079:2008"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat zimny Wskaźnik IREQmin, Wskaźnik IREQneutral, Wskaźnik twc (z obliczeń) PN-EN ISO 11079:2008 Srodowisko pracy - mikroklimat zimny Wskaznik IREQmin, Wskaznik IREQneutral, Wskaznik twc (z obliczen) PN-EN ISO 11079:2008","categories":["environment"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"IREQmin index, IREQneutral index, twc index (calculated)","search_en":"Workplace environment - cold microclimate IREQmin index, IREQneutral index, twc index (calculated) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-EN ISO 11079:2008","test_object_en":"Workplace environment - cold microclimate","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","search_zh":"工作场所环境 — 低温微气候 IREQmin 指数、IREQneutral 指数、twc 指数（计算值） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-EN ISO 11079:2008","test_object_zh":"工作场所环境 — 低温微气候","methodology_zh":"IREQmin 指数、IREQneutral 指数、twc 指数（计算值）"},{"_id":"6a7d7be00636ba417e41bfdc","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Temperatura powietrza","parameters":[{"name":"Zakres","range":"(5,0 - 60,0) °C"},{"name":"Temperatura poczernionej kuli"},{"name":"Zakres","range":"(5,0 - 60,0) °C"},{"name":"Wilgotność"},{"name":"Zakres","range":"(20,0 - 90,0) %"},{"name":"Prędkość powietrza"},{"name":"Zakres","range":"(0,15 - 2,0) m/s"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Temperatura powietrza\nZakres:\nZakres (5,0 - 60,0) °C\nTemperatura poczernionej kuli\nZakres (5,0 - 60,0) °C\nWilgotność\nZakres (20,0 - 90,0) %\nPrędkość powietrza\nZakres (0,15 - 2,0) m/s\nMetoda pomiarowa bezpośrednia","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (5,0 - 60,0) °C\nTemperatura poczernionej kuli\nZakres (5,0 - 60,0) °C\nWilgotność\nZakres (20,0 - 90,0) %\nPrędkość powietrza\nZakres (0,15 - 2,0) m/s\nMetoda pomiarowa bezpośrednia PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Temperatura powietrza\nZakres:\nZakres (5,0 - 60,0) °C\nTemperatura poczernionej kuli\nZakres (5,0 - 60,0) °C\nWilgotnosc\nZakres (20,0 - 90,0) %\nPredkosc powietrza\nZakres (0,15 - 2,0) m/s\nMetoda pomiarowa bezposrednia PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Air temperature","parameters_en":[{"name":"Range","range":"(5,0 - 60,0) °C"},{"name":"Black globe temperature"},{"name":"Range","range":"(5,0 - 60,0) °C"},{"name":"Humidity"},{"name":"Range","range":"(20,0 - 90,0) %"},{"name":"Air velocity"},{"name":"Range","range":"(0,15 - 2,0) m/s"}],"search_en":"Workplace environment - moderate microclimate Air temperature Direct measurement method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Black globe temperature Range Humidity Range Air velocity Range PN-EN ISO 7730:2006+Ap2:2016-04","technique_en":"Direct measurement method","test_object_en":"Workplace environment - moderate microclimate","methodology_zh":"空气温度","parameters_zh":[{"name":"范围","range":"(5,0 - 60,0) °C"},{"name":"黑球温度"},{"name":"范围","range":"(5,0 - 60,0) °C"},{"name":"湿度"},{"name":"范围","range":"(20,0 - 90,0) %"},{"name":"空气流速"},{"name":"范围","range":"(0,15 - 2,0) m/s"}],"search_zh":"工作场所环境 — 中等微气候 空气温度 直接测量法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 黑球温度 范围 湿度 范围 空气流速 范围 PN-EN ISO 7730:2006+Ap2:2016-04","technique_zh":"直接测量法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a7d7be00636ba417e41bfdd","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - mikroklimat umiarkowany","methodology":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik PMV, Wskaźnik PPD (z obliczeń)","reference":"PN-EN ISO 7730:2006+Ap2:2016-04","norm_bases":["PN-EN ISO 7730:2006+Ap2:2016-04"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - mikroklimat umiarkowany Wskaźnik PMV, Wskaźnik PPD (z obliczeń) PN-EN ISO 7730:2006+Ap2:2016-04 Srodowisko pracy - mikroklimat umiarkowany Wskaznik PMV, Wskaznik PPD (z obliczen) PN-EN ISO 7730:2006+Ap2:2016-04","categories":["environment"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"PMV index, PPD index (calculated)","search_en":"Workplace environment - moderate microclimate PMV index, PPD index (calculated) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-EN ISO 7730:2006+Ap2:2016-04","test_object_en":"Workplace environment - moderate microclimate","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"PMV 指数、PPD 指数（计算值）","search_zh":"工作场所环境 — 中等微气候 PMV 指数、PPD 指数（计算值） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-EN ISO 7730:2006+Ap2:2016-04","test_object_zh":"工作场所环境 — 中等微气候"},{"_id":"6a7d7be00636ba417e41bfde","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"czynniki pyłowe frakcja wdychalna frakcja respirabilne"},{"name":"substancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna"},{"name":"substancje organiczne, w tym frakcja wdychalna"},{"name":"metale i ich związki, w tym frakcja wdychalna frakcja respirabilna"},{"name":"azbest"},{"name":"włókna respirabilne"},{"name":"ogniotrwałe włókna ceramiczne,"},{"name":"ogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi"},{"name":"sztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych"},{"name":"włókna respirabilne"}],"technique":"Metoda dozymetrii indywidualnej","techniques":["Metoda dozymetrii indywidualnej"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe frakcja wdychalna frakcja respirabilne\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna\nsubstancje organiczne, w tym frakcja wdychalna\nmetale i ich związki, w tym frakcja wdychalna frakcja respirabilna\nazbest\nwłókna respirabilne\nogniotrwałe włókna ceramiczne,\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nwłókna respirabilne\nMetoda dozymetrii indywidualnej","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002+Az1:2004"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nczynniki pyłowe frakcja wdychalna frakcja respirabilne\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna\nsubstancje organiczne, w tym frakcja wdychalna\nmetale i ich związki, w tym frakcja wdychalna frakcja respirabilna\nazbest\nwłókna respirabilne\nogniotrwałe włókna ceramiczne,\nogniotrwałe włókna ceramiczne w mieszaninie z innymi sztucznymi włóknami mineralnymi\nsztuczne włókna mineralne, z wyjątkiem ogniotrwałych włókien ceramicznych\nwłókna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nczynniki pylowe frakcja wdychalna frakcja respirabilne\nsubstancje nieorganiczne, w tym frakcja wdychalna frakcja respirabilna frakcja torakalna\nsubstancje organiczne, w tym frakcja wdychalna\nmetale i ich zwiazki, w tym frakcja wdychalna frakcja respirabilna\nazbest\nwlokna respirabilne\nogniotrwale wlokna ceramiczne,\nogniotrwale wlokna ceramiczne w mieszaninie z innymi sztucznymi wloknami mineralnymi\nsztuczne wlokna mineralne, z wyjatkiem ogniotrwalych wlokien ceramicznych\nwlokna respirabilne\nMetoda dozymetrii indywidualnej PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","categories":["materials","environment"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"dust agents inhalable fraction respirable fraction"},{"name":"inorganic substances, including inhalable fraction respirable fraction thoracic fraction"},{"name":"organic substances, including inhalable fraction"},{"name":"metals and their compounds, including inhalable fraction respirable fraction"},{"name":"asbestos"},{"name":"respirable fibres"},{"name":"refractory ceramic fibres,"},{"name":"refractory ceramic fibres mixed with other man-made mineral fibres"},{"name":"man-made mineral fibres, excluding refractory ceramic fibres"},{"name":"respirable fibres"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Personal dosimetry method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. dust agents inhalable fraction respirable fraction inorganic substances, including inhalable fraction respirable fraction thoracic fraction organic substances, including inhalable fraction metals and their compounds, including inhalable fraction respirable fraction asbestos respirable fibres refractory ceramic fibres, refractory ceramic fibres mixed with other man-made mineral fibres man-made mineral fibres, excluding refractory ceramic fibres respirable fibres PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","technique_en":"Personal dosimetry method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 个体剂量测定法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 无机物质，其中包括 可吸入性粉尘 呼吸性粉尘 胸腔性粉尘 有机物质，其中包括可吸入性粉尘 金属及其化合物，其中包括 可吸入性粉尘 呼吸性粉尘 石棉 呼吸性纤维 与其他人造矿物纤维混合的耐火陶瓷纤维 人造矿物纤维，耐火陶瓷纤维除外 呼吸性纤维 PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","technique_zh":"个体剂量测定法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","parameters_zh":[{"name":"czynniki pyłowe frakcja wdychalna frakcja respirabilne"},{"name":"无机物质，其中包括 可吸入性粉尘 呼吸性粉尘 胸腔性粉尘"},{"name":"有机物质，其中包括可吸入性粉尘"},{"name":"金属及其化合物，其中包括 可吸入性粉尘 呼吸性粉尘"},{"name":"石棉"},{"name":"呼吸性纤维"},{"name":"ogniotrwałe włókna ceramiczne,"},{"name":"与其他人造矿物纤维混合的耐火陶瓷纤维"},{"name":"人造矿物纤维，耐火陶瓷纤维除外"},{"name":"呼吸性纤维"}]},{"_id":"6a7d7be00636ba417e41bfdf","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Pobieranie próbek do oceny narażenia zawodowego na:","parameters":[{"name":"substancje nieorganiczne, w tym frakcja wdychalna"},{"name":"substancje organiczne, w tym frakcja wdychalna"}],"technique":"Metoda stacjonarna","techniques":["Metoda stacjonarna"],"computed":[],"activity":"Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje nieorganiczne, w tym frakcja wdychalna\nsubstancje organiczne, w tym frakcja wdychalna\nMetoda stacjonarna","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002+Az1:2004"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Pobieranie próbek do oceny narażenia zawodowego na:\nZakres:\nsubstancje nieorganiczne, w tym frakcja wdychalna\nsubstancje organiczne, w tym frakcja wdychalna\nMetoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Pobieranie probek do oceny narazenia zawodowego na:\nZakres:\nsubstancje nieorganiczne, w tym frakcja wdychalna\nsubstancje organiczne, w tym frakcja wdychalna\nMetoda stacjonarna PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Sampling for the assessment of occupational exposure to:","parameters_en":[{"name":"inorganic substances, including inhalable fraction"},{"name":"organic substances, including inhalable fraction"}],"search_en":"Workplace environment - air Sampling for the assessment of occupational exposure to: Stationary method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. inorganic substances, including inhalable fraction organic substances, including inhalable fraction PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","technique_en":"Stationary method","test_object_en":"Workplace environment - air","methodology_zh":"职业接触评估采样，针对：","search_zh":"工作场所环境 — 空气 职业接触评估采样，针对： 定点测定法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 有机物质，其中包括可吸入性粉尘 PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","technique_zh":"定点测定法","parameters_zh":[{"name":"substancje nieorganiczne, w tym frakcja wdychalna"},{"name":"有机物质，其中包括可吸入性粉尘"}]},{"_id":"6a7d7be00636ba417e41bfe0","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Wskaźnik narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźnik narażenia (z obliczeń)","reference":"PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","norm_bases":["PN-Z-04008-7:2002","PN-Z-04008-7:2002+Az1:2004"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Wskaźnik narażenia (z obliczeń) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004 Srodowisko pracy - powietrze Wskaznik narazenia (z obliczen) PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","categories":["environment"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Exposure index (calculated)","search_en":"Workplace environment - air Exposure index (calculated) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","test_object_en":"Workplace environment - air","methodology_zh":"暴露指数（计算得出）","search_zh":"工作场所环境 — 空气 暴露指数（计算得出） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PN-Z-04008-7:2002 | PN-Z-04008-7:2002+Az1:2004","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bfe1","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,09 - 20,4) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres (0,09 - 20,4) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04507:2022-05","PN-Z-04507:2022-05/Ap1:2022-08"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja wdychalna\nZakres (0,09 - 20,4) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja wdychalna\nZakres (0,09 - 20,4) mg/m3\nMetoda grawimetryczna PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","categories":["environment"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration of harmful dust agents – inhalable fraction","parameters_en":[{"name":"Range","range":"(0,09 - 20,4) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – inhalable fraction Gravimetric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,09 - 20,4) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 可吸入组分 重量法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 PN-Z-04507:2022-05 | PN-Z-04507:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"有害粉尘因素浓度 — 可吸入组分"},{"_id":"6a7d7be00636ba417e41bfe2","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna","parameters":[{"name":"Zakres","range":"(0,07 - 9,3) mg/m3"}],"technique":"Metoda grawimetryczna","techniques":["Metoda grawimetryczna"],"computed":[],"activity":"Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres (0,07 - 9,3) mg/m3\nMetoda grawimetryczna","reference":"PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","norm_bases":["PN-Z-04508:2022-05","PN-Z-04508:2022-05/Ap1:2022-08"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie pyłowych czynników szkodliwych dla zdrowia – frakcja respirabilna\nZakres (0,07 - 9,3) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08 Srodowisko pracy - powietrze Stezenie pylowych czynnikow szkodliwych dla zdrowia – frakcja respirabilna\nZakres (0,07 - 9,3) mg/m3\nMetoda grawimetryczna PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","categories":["environment"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration of harmful dust agents – respirable fraction","parameters_en":[{"name":"Range","range":"(0,07 - 9,3) mg/m3"}],"search_en":"Workplace environment - air Concentration of harmful dust agents – respirable fraction Gravimetric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_en":"Gravimetric method","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"范围","range":"(0,07 - 9,3) mg/m3"}],"search_zh":"工作场所环境 — 空气 有害粉尘因素浓度 — 呼吸性组分 重量法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 PN-Z-04508:2022-05 | PN-Z-04508:2022-05/Ap1:2022-08","technique_zh":"重量法","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"有害粉尘因素浓度 — 呼吸性组分"},{"_id":"6a7d7be00636ba417e41bfe3","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość amoniaku","parameters":[{"name":"Zakres","range":"(0,08 - 56) mg/m3"},{"name":"Zakres","range":"(14 - 420) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość amoniaku\nZakres:\nZakres (0,08 - 56) mg/m3\nZakres (14 - 420) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-71/Z-04041","norm_bases":["PN-71/Z-04041"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość amoniaku\nZakres:\nZakres (0,08 - 56) mg/m3\nZakres (14 - 420) μg w próbce\nMetoda spektrofotometryczna PN-71/Z-04041 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc amoniaku\nZakres:\nZakres (0,08 - 56) mg/m3\nZakres (14 - 420) μg w probce\nMetoda spektrofotometryczna PN-71/Z-04041","categories":["environment"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Ammonia concentration/content","parameters_en":[{"name":"Range","range":"(0,08 - 56) mg/m3"},{"name":"Range","range":"(14 - 420) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Ammonia concentration/content Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-71/Z-04041","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,08 - 56) mg/m3"},{"name":"范围","range":"(14 - 420) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 氨浓度/含量 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-71/Z-04041","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"氨浓度/含量"},{"_id":"6a7d7be00636ba417e41bfe4","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość chloru","parameters":[{"name":"Zakres","range":"(0,002 - 3) mg/m3"},{"name":"Zakres","range":"(0,4 - 540) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chloru\nZakres:\nZakres (0,002 - 3) mg/m3\nZakres (0,4 - 540) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-75/Z-04037/03","norm_bases":["PN-75/Z-04037/03"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość chloru\nZakres:\nZakres (0,002 - 3) mg/m3\nZakres (0,4 - 540) μg w próbce\nMetoda spektrofotometryczna PN-75/Z-04037/03 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc chloru\nZakres:\nZakres (0,002 - 3) mg/m3\nZakres (0,4 - 540) μg w probce\nMetoda spektrofotometryczna PN-75/Z-04037/03","categories":["environment"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Chlorine concentration/content","parameters_en":[{"name":"Range","range":"(0,002 - 3) mg/m3"},{"name":"Range","range":"(0,4 - 540) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Chlorine concentration/content Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-75/Z-04037/03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,002 - 3) mg/m3"},{"name":"范围","range":"(0,4 - 540) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 氯的浓度/含量 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-75/Z-04037/03","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"氯的浓度/含量"},{"_id":"6a7d7be00636ba417e41bfe5","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość cyjanowodoru","parameters":[{"name":"Zakres","range":"(0,075 - 5) mg/m3"},{"name":"Zakres","range":"(0,066 - 4,5) ppm"},{"name":"Zakres","range":"(0,3 - 20,0) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość cyjanowodoru\nZakres:\nZakres (0,075 - 5) mg/m3\nZakres (0,066 - 4,5) ppm\nZakres (0,3 - 20,0) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-70/Z-04053","norm_bases":["PN-70/Z-04053"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość cyjanowodoru\nZakres:\nZakres (0,075 - 5) mg/m3\nZakres (0,066 - 4,5) ppm\nZakres (0,3 - 20,0) μg w próbce\nMetoda spektrofotometryczna PN-70/Z-04053 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc cyjanowodoru\nZakres:\nZakres (0,075 - 5) mg/m3\nZakres (0,066 - 4,5) ppm\nZakres (0,3 - 20,0) μg w probce\nMetoda spektrofotometryczna PN-70/Z-04053","categories":["environment"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of hydrogen cyanide","parameters_en":[{"name":"Range","range":"(0,075 - 5) mg/m3"},{"name":"Range","range":"(0,066 - 4,5) ppm"},{"name":"Range","range":"(0,3 - 20,0) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Concentration/content of hydrogen cyanide Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range Range PN-70/Z-04053","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,075 - 5) mg/m3"},{"name":"范围","range":"(0,066 - 4,5) ppm"},{"name":"范围","range":"(0,3 - 20,0) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 范围 PN-70/Z-04053","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a7d7be00636ba417e41bfe6","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość ditlenku siarki","parameters":[{"name":"Zakres","range":"(0,009 - 10) mg/m3"},{"name":"Zakres","range":"(0,0033 - 3,77) ppm"},{"name":"Zakres","range":"(3,2 - 3600) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ditlenku siarki\nZakres:\nZakres (0,009 - 10) mg/m3\nZakres (0,0033 - 3,77) ppm\nZakres (3,2 - 3600) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04015-12:1996 | PN-Z-04015-12:1996+Ap1:2001","norm_bases":["PN-Z-04015-12:1996","PN-Z-04015-12:1996+Ap1:2001"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość ditlenku siarki\nZakres:\nZakres (0,009 - 10) mg/m3\nZakres (0,0033 - 3,77) ppm\nZakres (3,2 - 3600) μg w próbce\nMetoda spektrofotometryczna PN-Z-04015-12:1996 | PN-Z-04015-12:1996+Ap1:2001 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc ditlenku siarki\nZakres:\nZakres (0,009 - 10) mg/m3\nZakres (0,0033 - 3,77) ppm\nZakres (3,2 - 3600) μg w probce\nMetoda spektrofotometryczna PN-Z-04015-12:1996 | PN-Z-04015-12:1996+Ap1:2001","categories":["environment"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Sulphur dioxide concentration/content","parameters_en":[{"name":"Range","range":"(0,009 - 10) mg/m3"},{"name":"Range","range":"(0,0033 - 3,77) ppm"},{"name":"Range","range":"(3,2 - 3600) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Sulphur dioxide concentration/content Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range Range PN-Z-04015-12:1996 | PN-Z-04015-12:1996+Ap1:2001","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,009 - 10) mg/m3"},{"name":"范围","range":"(0,0033 - 3,77) ppm"},{"name":"范围","range":"(3,2 - 3600) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 二氧化硫的浓度/含量 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 范围 PN-Z-04015-12:1996 | PN-Z-04015-12:1996+Ap1:2001","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"二氧化硫的浓度/含量"},{"_id":"6a7d7be00636ba417e41bfe7","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie tlenku węgla","parameters":[{"name":"Zakres","range":"(2,1 - 239) mg/m3"},{"name":"Zakres","range":"(1,8 - 206) ppm"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"Stężenie tlenku węgla\nZakres:\nZakres (2,1 - 239) mg/m3\nZakres (1,8 - 206) ppm\nMetoda elektrochemiczna","reference":"PB-05 wydanie 1 z dnia 01.12.2008 r.","norm_bases":["PB-05 wydanie 1 z dnia 01.12.2008 r."],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie tlenku węgla\nZakres:\nZakres (2,1 - 239) mg/m3\nZakres (1,8 - 206) ppm\nMetoda elektrochemiczna PB-05 wydanie 1 z dnia 01.12.2008 r. Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie tlenku wegla\nZakres:\nZakres (2,1 - 239) mg/m3\nZakres (1,8 - 206) ppm\nMetoda elektrochemiczna PB-05 wydanie 1 z dnia 01.12.2008 r.","categories":["environment"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Carbon monoxide concentration","parameters_en":[{"name":"Range","range":"(2,1 - 239) mg/m3"},{"name":"Range","range":"(1,8 - 206) ppm"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Carbon monoxide concentration Electrochemical method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PB-05 wydanie 1 z dnia 01.12.2008 r.","technique_en":"Electrochemical method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(2,1 - 239) mg/m3"},{"name":"范围","range":"(1,8 - 206) ppm"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 一氧化碳浓度 电化学法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PB-05 wydanie 1 z dnia 01.12.2008 r.","technique_zh":"电化学法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"一氧化碳浓度","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a7d7be00636ba417e41bfe8","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Wskaźniki narażenia (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Wskaźniki narażenia (z obliczeń)","reference":"PB-05 wydanie 1 z dnia 01.12.2008 r.","norm_bases":["PB-05 wydanie 1 z dnia 01.12.2008 r."],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Wskaźniki narażenia (z obliczeń) PB-05 wydanie 1 z dnia 01.12.2008 r. Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Wskazniki narazenia (z obliczen) PB-05 wydanie 1 z dnia 01.12.2008 r.","categories":["environment"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Exposure indices (calculated)","search_en":"Workplace environment - air - air samples collected into absorbing solution Exposure indices (calculated) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PB-05 wydanie 1 z dnia 01.12.2008 r.","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 暴露指数（计算值） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PB-05 wydanie 1 z dnia 01.12.2008 r.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"暴露指数（计算值）"},{"_id":"6a7d7be00636ba417e41bfe9","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość formaldehydu i akroleiny","parameters":[{"name":"Formaldehyd","range":"(0,002 - 2) mg/m3"},{"name":"Zakres","range":"(0,3 - 360) μg w próbce"},{"name":"Akrylaldehyd (Akroleina)","range":"(0,002 - 0,2) mg/m3"},{"name":"(0,00086 - 0,086) ppm"},{"name":"(0,3 - 36) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość formaldehydu i akroleiny\nZakres:\nFormaldehyd (0,002 - 2) mg/m3\nZakres (0,3 - 360) μg w próbce\nAkrylaldehyd (Akroleina) (0,002 - 0,2) mg/m3\n(0,00086 - 0,086) ppm\n(0,3 - 36) μg w próbce\nMetoda spektrofotometryczna","reference":"PB-02 wydanie 2 z dnia 01.08.2006 r.","norm_bases":["PB-02 wydanie 2 z dnia 01.08.2006 r."],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość formaldehydu i akroleiny\nZakres:\nFormaldehyd (0,002 - 2) mg/m3\nZakres (0,3 - 360) μg w próbce\nAkrylaldehyd (Akroleina) (0,002 - 0,2) mg/m3\n(0,00086 - 0,086) ppm\n(0,3 - 36) μg w próbce\nMetoda spektrofotometryczna PB-02 wydanie 2 z dnia 01.08.2006 r. Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc formaldehydu i akroleiny\nZakres:\nFormaldehyd (0,002 - 2) mg/m3\nZakres (0,3 - 360) μg w probce\nAkrylaldehyd (Akroleina) (0,002 - 0,2) mg/m3\n(0,00086 - 0,086) ppm\n(0,3 - 36) μg w probce\nMetoda spektrofotometryczna PB-02 wydanie 2 z dnia 01.08.2006 r.","categories":["environment"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of formaldehyde and acrolein","parameters_en":[{"name":"Formaldehyde","range":"(0,002 - 2) mg/m3"},{"name":"Range","range":"(0,3 - 360) μg w próbce"},{"name":"Acrylaldehyde (Acrolein)","range":"(0,002 - 0,2) mg/m3"},{"name":"(0,00086 - 0,086) ppm"},{"name":"(0,3 - 36) μg in the sample"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Concentration/content of formaldehyde and acrolein Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Formaldehyde Range Acrylaldehyde (Acrolein) (0,00086 - 0,086) ppm (0,3 - 36) μg in the sample PB-02 wydanie 2 z dnia 01.08.2006 r.","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"Formaldehyd","range":"(0,002 - 2) mg/m3"},{"name":"范围","range":"(0,3 - 360) μg w próbce"},{"name":"Akrylaldehyd (Akroleina)","range":"(0,002 - 0,2) mg/m3"},{"name":"(0,00086 - 0,086) ppm"},{"name":"(0,3 - 36) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 PB-02 wydanie 2 z dnia 01.08.2006 r.","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a7d7be00636ba417e41bfea","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość formaldehydu","parameters":[{"name":"Zakres","range":"(0,011 - 10,7) mg/m3"},{"name":"Zakres","range":"(1,0 - 80) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,011 - 10,7) mg/m3\nZakres (1,0 - 80) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-76/Z-04045/02","norm_bases":["PN-76/Z-04045/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość formaldehydu\nZakres:\nZakres (0,011 - 10,7) mg/m3\nZakres (1,0 - 80) μg w próbce\nMetoda spektrofotometryczna PN-76/Z-04045/02 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc formaldehydu\nZakres:\nZakres (0,011 - 10,7) mg/m3\nZakres (1,0 - 80) μg w probce\nMetoda spektrofotometryczna PN-76/Z-04045/02","categories":["environment"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Formaldehyde concentration/content","parameters_en":[{"name":"Range","range":"(0,011 - 10,7) mg/m3"},{"name":"Range","range":"(1,0 - 80) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Formaldehyde concentration/content Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-76/Z-04045/02","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,011 - 10,7) mg/m3"},{"name":"范围","range":"(1,0 - 80) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 甲醛浓度/含量 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-76/Z-04045/02","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"甲醛浓度/含量"},{"_id":"6a7d7be00636ba417e41bfeb","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość kwasu fosforowego (V) i dekatlenku tetrafosforu","parameters":[{"name":"Zakres","range":"(0,008 - 4) mg/m3"},{"name":"Zakres","range":"(1,4 - 720) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość kwasu fosforowego (V) i dekatlenku tetrafosforu\nZakres:\nZakres (0,008 - 4) mg/m3\nZakres (1,4 - 720) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04073-1:2014-08","norm_bases":["PN-Z-04073-1:2014-08"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość kwasu fosforowego (V) i dekatlenku tetrafosforu\nZakres:\nZakres (0,008 - 4) mg/m3\nZakres (1,4 - 720) μg w próbce\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc kwasu fosforowego (V) i dekatlenku tetrafosforu\nZakres:\nZakres (0,008 - 4) mg/m3\nZakres (1,4 - 720) μg w probce\nMetoda spektrofotometryczna PN-Z-04073-1:2014-08","categories":["environment"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of phosphoric(V) acid and tetraphosphorus decaoxide","parameters_en":[{"name":"Range","range":"(0,008 - 4) mg/m3"},{"name":"Range","range":"(1,4 - 720) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Concentration/content of phosphoric(V) acid and tetraphosphorus decaoxide Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04073-1:2014-08","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,008 - 4) mg/m3"},{"name":"范围","range":"(1,4 - 720) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04073-1:2014-08","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a7d7be00636ba417e41bfec","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość jodu","parameters":[{"name":"Zakres","range":"(0,05 - 2) mg/m3"},{"name":"Zakres","range":"(8,0 - 360) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość jodu\nZakres:\nZakres (0,05 - 2) mg/m3\nZakres (8,0 - 360) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04433:2011","norm_bases":["PN-Z-04433:2011"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość jodu\nZakres:\nZakres (0,05 - 2) mg/m3\nZakres (8,0 - 360) μg w próbce\nMetoda spektrofotometryczna PN-Z-04433:2011 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc jodu\nZakres:\nZakres (0,05 - 2) mg/m3\nZakres (8,0 - 360) μg w probce\nMetoda spektrofotometryczna PN-Z-04433:2011","categories":["environment"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Iodine concentration/content","parameters_en":[{"name":"Range","range":"(0,05 - 2) mg/m3"},{"name":"Range","range":"(8,0 - 360) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Iodine concentration/content Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04433:2011","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,05 - 2) mg/m3"},{"name":"范围","range":"(8,0 - 360) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04433:2011","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a7d7be00636ba417e41bfed","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość kwasu mrówkowego","parameters":[{"name":"Zakres","range":"(0,08 - 30) mg/m3"},{"name":"Zakres","range":"(20 - 7200) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość kwasu mrówkowego\nZakres:\nZakres (0,08 - 30) mg/m3\nZakres (20 - 7200) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-88/Z-04196/02","norm_bases":["PN-88/Z-04196/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość kwasu mrówkowego\nZakres:\nZakres (0,08 - 30) mg/m3\nZakres (20 - 7200) μg w próbce\nMetoda spektrofotometryczna PN-88/Z-04196/02 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc kwasu mrowkowego\nZakres:\nZakres (0,08 - 30) mg/m3\nZakres (20 - 7200) μg w probce\nMetoda spektrofotometryczna PN-88/Z-04196/02","categories":["environment"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Formic acid concentration/content","parameters_en":[{"name":"Range","range":"(0,08 - 30) mg/m3"},{"name":"Range","range":"(20 - 7200) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Formic acid concentration/content Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-88/Z-04196/02","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,08 - 30) mg/m3"},{"name":"范围","range":"(20 - 7200) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 甲酸的浓度/含量 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-88/Z-04196/02","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"甲酸的浓度/含量"},{"_id":"6a7d7be00636ba417e41bfee","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość nadtlenku wodoru","parameters":[{"name":"Zakres","range":"(0,04 - 2,1) mg/m3"},{"name":"Zakres","range":"(0,4 - 9,6) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość nadtlenku wodoru\nZakres:\nZakres (0,04 - 2,1) mg/m3\nZakres (0,4 - 9,6) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04548:2023-03","norm_bases":["PN-Z-04548:2023-03"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość nadtlenku wodoru\nZakres:\nZakres (0,04 - 2,1) mg/m3\nZakres (0,4 - 9,6) μg w próbce\nMetoda spektrofotometryczna PN-Z-04548:2023-03 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc nadtlenku wodoru\nZakres:\nZakres (0,04 - 2,1) mg/m3\nZakres (0,4 - 9,6) μg w probce\nMetoda spektrofotometryczna PN-Z-04548:2023-03","categories":["environment"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Hydrogen peroxide concentration/content","parameters_en":[{"name":"Range","range":"(0,04 - 2,1) mg/m3"},{"name":"Range","range":"(0,4 - 9,6) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Hydrogen peroxide concentration/content Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04548:2023-03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,04 - 2,1) mg/m3"},{"name":"范围","range":"(0,4 - 9,6) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 过氧化氢的浓度/含量 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04548:2023-03","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"过氧化氢的浓度/含量"},{"_id":"6a7d7be00636ba417e41bfef","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość ozonu","parameters":[{"name":"Zakres","range":"(0,015 - 0,3) mg/m3"},{"name":"Zakres","range":"(1,05 - 21) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość ozonu\nZakres:\nZakres (0,015 - 0,3) mg/m3\nZakres (1,05 - 21) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04007-2:1994","norm_bases":["PN-Z-04007-2:1994"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość ozonu\nZakres:\nZakres (0,015 - 0,3) mg/m3\nZakres (1,05 - 21) μg w próbce\nMetoda spektrofotometryczna PN-Z-04007-2:1994 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc ozonu\nZakres:\nZakres (0,015 - 0,3) mg/m3\nZakres (1,05 - 21) μg w probce\nMetoda spektrofotometryczna PN-Z-04007-2:1994","categories":["environment"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Ozone concentration/content","parameters_en":[{"name":"Range","range":"(0,015 - 0,3) mg/m3"},{"name":"Range","range":"(1,05 - 21) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Ozone concentration/content Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04007-2:1994","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,015 - 0,3) mg/m3"},{"name":"范围","range":"(1,05 - 21) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 臭氧的浓度/含量 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04007-2:1994","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"臭氧的浓度/含量"},{"_id":"6a7d7be00636ba417e41bff0","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość siarkowodoru","parameters":[{"name":"Zakres","range":"(0,05 - 40) mg/m3"},{"name":"Zakres","range":"(18 - 14400) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,05 - 40) mg/m3\nZakres (18 - 14400) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04015-13:1996","norm_bases":["PN-Z-04015-13:1996"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość siarkowodoru\nZakres:\nZakres (0,05 - 40) mg/m3\nZakres (18 - 14400) μg w próbce\nMetoda spektrofotometryczna PN-Z-04015-13:1996 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc siarkowodoru\nZakres:\nZakres (0,05 - 40) mg/m3\nZakres (18 - 14400) μg w probce\nMetoda spektrofotometryczna PN-Z-04015-13:1996","categories":["environment"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Hydrogen sulphide concentration/content","parameters_en":[{"name":"Range","range":"(0,05 - 40) mg/m3"},{"name":"Range","range":"(18 - 14400) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Hydrogen sulphide concentration/content Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04015-13:1996","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,05 - 40) mg/m3"},{"name":"范围","range":"(18 - 14400) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 硫化氢的浓度/含量 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04015-13:1996","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"硫化氢的浓度/含量"},{"_id":"6a7d7be00636ba417e41bff1","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość tlenku i ditlenku azotu","parameters":[{"name":"tlenek azotu","range":"(0,22 - 23,1) mg/m3"},{"name":"Zakres","range":"(0,176 - 18,55) ppm"},{"name":"Zakres","range":"(1,3 - 104) μg w próbce"},{"name":"ditlenek azotu","range":"(0,067 - 7,11) mg/m3"},{"name":"(0,035 - 3,72) ppm"},{"name":"(0,4 - 16) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość tlenku i ditlenku azotu\nZakres:\ntlenek azotu (0,22 - 23,1) mg/m3\nZakres (0,176 - 18,55) ppm\nZakres (1,3 - 104) μg w próbce\nditlenek azotu (0,067 - 7,11) mg/m3\n(0,035 - 3,72) ppm\n(0,4 - 16) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04009-11:2008","norm_bases":["PN-Z-04009-11:2008"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość tlenku i ditlenku azotu\nZakres:\ntlenek azotu (0,22 - 23,1) mg/m3\nZakres (0,176 - 18,55) ppm\nZakres (1,3 - 104) μg w próbce\nditlenek azotu (0,067 - 7,11) mg/m3\n(0,035 - 3,72) ppm\n(0,4 - 16) μg w próbce\nMetoda spektrofotometryczna PN-Z-04009-11:2008 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc tlenku i ditlenku azotu\nZakres:\ntlenek azotu (0,22 - 23,1) mg/m3\nZakres (0,176 - 18,55) ppm\nZakres (1,3 - 104) μg w probce\nditlenek azotu (0,067 - 7,11) mg/m3\n(0,035 - 3,72) ppm\n(0,4 - 16) μg w probce\nMetoda spektrofotometryczna PN-Z-04009-11:2008","categories":["environment"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of nitrogen monoxide and nitrogen dioxide","parameters_en":[{"name":"nitrogen oxide","range":"(0,22 - 23,1) mg/m3"},{"name":"Range","range":"(0,176 - 18,55) ppm"},{"name":"Range","range":"(1,3 - 104) μg w próbce"},{"name":"nitrogen dioxide","range":"(0,067 - 7,11) mg/m3"},{"name":"(0,035 - 3,72) ppm"},{"name":"(0,4 - 16) μg in the sample"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Concentration/content of nitrogen monoxide and nitrogen dioxide Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. nitrogen oxide Range Range nitrogen dioxide (0,035 - 3,72) ppm (0,4 - 16) μg in the sample PN-Z-04009-11:2008","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"一氧化氮","range":"(0,22 - 23,1) mg/m3"},{"name":"范围","range":"(0,176 - 18,55) ppm"},{"name":"范围","range":"(1,3 - 104) μg w próbce"},{"name":"二氧化氮","range":"(0,067 - 7,11) mg/m3"},{"name":"(0,035 - 3,72) ppm"},{"name":"(0,4 - 16) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 一氧化氮 范围 范围 二氧化氮 PN-Z-04009-11:2008","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品"},{"_id":"6a7d7be00636ba417e41bff2","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość wodorotlenku potasu","parameters":[{"name":"Zakres","range":"(0,02 - 2,3) mg/m3"},{"name":"Zakres","range":"(7,3 - 810) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość wodorotlenku potasu\nZakres:\nZakres (0,02 - 2,3) mg/m3\nZakres (7,3 - 810) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-87/Z-04005/03","norm_bases":["PN-87/Z-04005/03"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość wodorotlenku potasu\nZakres:\nZakres (0,02 - 2,3) mg/m3\nZakres (7,3 - 810) μg w próbce\nMetoda spektrofotometryczna PN-87/Z-04005/03 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc wodorotlenku potasu\nZakres:\nZakres (0,02 - 2,3) mg/m3\nZakres (7,3 - 810) μg w probce\nMetoda spektrofotometryczna PN-87/Z-04005/03","categories":["environment"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Potassium hydroxide concentration/content","parameters_en":[{"name":"Range","range":"(0,02 - 2,3) mg/m3"},{"name":"Range","range":"(7,3 - 810) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Potassium hydroxide concentration/content Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-87/Z-04005/03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,02 - 2,3) mg/m3"},{"name":"范围","range":"(7,3 - 810) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 氢氧化钾的浓度/含量 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-87/Z-04005/03","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"氢氧化钾的浓度/含量"},{"_id":"6a7d7be00636ba417e41bff3","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego","methodology":"Stężenie/zawartość wodorotlenku sodu","parameters":[{"name":"Zakres","range":"(0,011 - 2,0) mg/m3"},{"name":"Zakres","range":"(4,3 - 709) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość wodorotlenku sodu\nZakres:\nZakres (0,011 - 2,0) mg/m3\nZakres (4,3 - 709) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-84/Z-04005/02","norm_bases":["PN-84/Z-04005/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane do roztworu pochłaniającego Stężenie/zawartość wodorotlenku sodu\nZakres:\nZakres (0,011 - 2,0) mg/m3\nZakres (4,3 - 709) μg w próbce\nMetoda spektrofotometryczna PN-84/Z-04005/02 Srodowisko pracy - powietrze - probki powietrza pobrane do roztworu pochlaniajacego Stezenie/zawartosc wodorotlenku sodu\nZakres:\nZakres (0,011 - 2,0) mg/m3\nZakres (4,3 - 709) μg w probce\nMetoda spektrofotometryczna PN-84/Z-04005/02","categories":["environment"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Sodium hydroxide concentration/content","parameters_en":[{"name":"Range","range":"(0,011 - 2,0) mg/m3"},{"name":"Range","range":"(4,3 - 709) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected into absorbing solution Sodium hydroxide concentration/content Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-84/Z-04005/02","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected into absorbing solution","parameters_zh":[{"name":"范围","range":"(0,011 - 2,0) mg/m3"},{"name":"范围","range":"(4,3 - 709) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品 氢氧化钠的浓度/含量 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-84/Z-04005/02","technique_zh":"分光光度法","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 采集于吸收液的空气样品","methodology_zh":"氢氧化钠的浓度/含量"},{"_id":"6a7d7be00636ba417e41bff4","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość metylenobisu (fenyloizocjanianu)","parameters":[{"name":"Zakres","range":"(0,0017 - 0,83) mg/m3"},{"name":"Zakres","range":"(0,62 - 12,5) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość metylenobisu (fenyloizocjanianu)\nZakres:\nZakres (0,0017 - 0,83) mg/m3\nZakres (0,62 - 12,5) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-81/Z-04131/02","norm_bases":["PN-81/Z-04131/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość metylenobisu (fenyloizocjanianu)\nZakres:\nZakres (0,0017 - 0,83) mg/m3\nZakres (0,62 - 12,5) μg w próbce\nMetoda spektrofotometryczna PN-81/Z-04131/02 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc metylenobisu (fenyloizocjanianu)\nZakres:\nZakres (0,0017 - 0,83) mg/m3\nZakres (0,62 - 12,5) μg w probce\nMetoda spektrofotometryczna PN-81/Z-04131/02","categories":["environment"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of methylenebis (phenyl isocyanate)","parameters_en":[{"name":"Range","range":"(0,0017 - 0,83) mg/m3"},{"name":"Range","range":"(0,62 - 12,5) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of methylenebis (phenyl isocyanate) Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-81/Z-04131/02","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,0017 - 0,83) mg/m3"},{"name":"范围","range":"(0,62 - 12,5) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-81/Z-04131/02","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bff5","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość baru","parameters":[{"name":"Zakres","range":"(0,07 - 1,8) mg/m3"},{"name":"Zakres","range":"(53 - 1282) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość baru\nZakres:\nZakres (0,07 - 1,8) mg/m3\nZakres (53 - 1282) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-82/Z-04024/02","norm_bases":["PN-82/Z-04024/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość baru\nZakres:\nZakres (0,07 - 1,8) mg/m3\nZakres (53 - 1282) μg w próbce\nMetoda spektrofotometryczna PN-82/Z-04024/02 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc baru\nZakres:\nZakres (0,07 - 1,8) mg/m3\nZakres (53 - 1282) μg w probce\nMetoda spektrofotometryczna PN-82/Z-04024/02","categories":["environment"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of barium","parameters_en":[{"name":"Range","range":"(0,07 - 1,8) mg/m3"},{"name":"Range","range":"(53 - 1282) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of barium Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-82/Z-04024/02","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,07 - 1,8) mg/m3"},{"name":"范围","range":"(53 - 1282) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-82/Z-04024/02","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bff6","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość chlorku amonu – pary i frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,12 - 40) mg/m3"},{"name":"Zakres","range":"(86 - 28800) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chlorku amonu – pary i frakcja wdychalna\nZakres:\nZakres (0,12 - 40) mg/m3\nZakres (86 - 28800) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-Z-04265:2000","norm_bases":["PN-Z-04265:2000"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość chlorku amonu – pary i frakcja wdychalna\nZakres:\nZakres (0,12 - 40) mg/m3\nZakres (86 - 28800) μg w próbce\nMetoda spektrofotometryczna PN-Z-04265:2000 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc chlorku amonu – pary i frakcja wdychalna\nZakres:\nZakres (0,12 - 40) mg/m3\nZakres (86 - 28800) μg w probce\nMetoda spektrofotometryczna PN-Z-04265:2000","categories":["environment"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of ammonium chloride – vapours and inhalable fraction","parameters_en":[{"name":"Range","range":"(0,12 - 40) mg/m3"},{"name":"Range","range":"(86 - 28800) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of ammonium chloride – vapours and inhalable fraction Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04265:2000","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,12 - 40) mg/m3"},{"name":"范围","range":"(86 - 28800) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04265:2000","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bff7","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość chromianów (VI) i dichromianów (VI) (chromiany) (w przeliczeniu na Cr (VI)","parameters":[{"name":"Zakres","range":"(0,006 - 0,6) mg/m3"},{"name":"Zakres","range":"(3,9 - 432) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość chromianów (VI) i dichromianów (VI) (chromiany) (w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,006 - 0,6) mg/m3\nZakres (3,9 - 432) μg w próbce\nMetoda spektrofotometryczna","reference":"PN-87/Z-04126/03","norm_bases":["PN-87/Z-04126/03"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość chromianów (VI) i dichromianów (VI) (chromiany) (w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,006 - 0,6) mg/m3\nZakres (3,9 - 432) μg w próbce\nMetoda spektrofotometryczna PN-87/Z-04126/03 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc chromianow (VI) i dichromianow (VI) (chromiany) (w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,006 - 0,6) mg/m3\nZakres (3,9 - 432) μg w probce\nMetoda spektrofotometryczna PN-87/Z-04126/03","categories":["environment"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of chromates (VI) and dichromates (VI) (chromates) (calculated as Cr (VI)","parameters_en":[{"name":"Range","range":"(0,006 - 0,6) mg/m3"},{"name":"Range","range":"(3,9 - 432) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of chromates (VI) and dichromates (VI) (chromates) (calculated as Cr (VI) Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-87/Z-04126/03","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,006 - 0,6) mg/m3"},{"name":"范围","range":"(3,9 - 432) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-87/Z-04126/03","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bff8","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość związków chromu (VI) - w przeliczeniu na Cr (VI)","parameters":[{"name":"Zakres","range":"(0,00028 - 0,02) mg/m3"},{"name":"Zakres","range":"(0,192 - 13,4) μg w próbce"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie/zawartość związków chromu (VI) - w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,00028 - 0,02) mg/m3\nZakres (0,192 - 13,4) μg w próbce\nMetoda spektrofotometryczna","reference":"NIOSH 7600:2015","norm_bases":["NIOSH 7600:2015"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość związków chromu (VI) - w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,00028 - 0,02) mg/m3\nZakres (0,192 - 13,4) μg w próbce\nMetoda spektrofotometryczna NIOSH 7600:2015 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc zwiazkow chromu (VI) - w przeliczeniu na Cr (VI)\nZakres:\nZakres (0,00028 - 0,02) mg/m3\nZakres (0,192 - 13,4) μg w probce\nMetoda spektrofotometryczna NIOSH 7600:2015","categories":["environment"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of chromium (VI) compounds - calculated as Cr (VI)","parameters_en":[{"name":"Range","range":"(0,00028 - 0,02) mg/m3"},{"name":"Range","range":"(0,192 - 13,4) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of chromium (VI) compounds - calculated as Cr (VI) Spectrophotometric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range NIOSH 7600:2015","technique_en":"Spectrophotometric method","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,00028 - 0,02) mg/m3"},{"name":"范围","range":"(0,192 - 13,4) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 分光光度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 NIOSH 7600:2015","technique_zh":"分光光度法","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bff9","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość chromu metalicznego, związków chromu: chromu(II), chromu (III),chromu (VI) w przeliczeniu na Cr.","parameters":[{"name":"Zakres","range":"(0,029 - 1,17) mg/m3"},{"name":"Zakres","range":"(20,0 - 800) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość chromu metalicznego, związków chromu: chromu(II), chromu (III),chromu (VI) w przeliczeniu na Cr.\nZakres:\nZakres (0,029 - 1,17) mg/m3\nZakres (20,0 - 800) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04434:2011","norm_bases":["PN-Z-04434:2011"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość chromu metalicznego, związków chromu: chromu(II), chromu (III),chromu (VI) w przeliczeniu na Cr.\nZakres:\nZakres (0,029 - 1,17) mg/m3\nZakres (20,0 - 800) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04434:2011 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc chromu metalicznego, zwiazkow chromu: chromu(II), chromu (III),chromu (VI) w przeliczeniu na Cr.\nZakres:\nZakres (0,029 - 1,17) mg/m3\nZakres (20,0 - 800) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04434:2011","categories":["materials","environment"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of metallic chromium, chromium compounds: chromium(II), chromium (III),chromium (VI) calculated as Cr.","parameters_en":[{"name":"Range","range":"(0,029 - 1,17) mg/m3"},{"name":"Range","range":"(20,0 - 800) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of metallic chromium, chromium compounds: chromium(II), chromium (III),chromium (VI) calculated as Cr. Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04434:2011","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,029 - 1,17) mg/m3"},{"name":"范围","range":"(20,0 - 800) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04434:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bffa","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie chromu metalicznego, związków chromu: chrom (II) - w przeliczeniu na Cr (II), chromu III – w przeliczeniu na Cr (III) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chromu metalicznego, związków chromu: chrom (II) - w przeliczeniu na Cr (II), chromu III – w przeliczeniu na Cr (III) (z obliczeń)","reference":"PB-03 wydanie 1 z dnia 01.04.2021 r.","norm_bases":["PB-03 wydanie 1 z dnia 01.04.2021 r."],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie chromu metalicznego, związków chromu: chrom (II) - w przeliczeniu na Cr (II), chromu III – w przeliczeniu na Cr (III) (z obliczeń) PB-03 wydanie 1 z dnia 01.04.2021 r. Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie chromu metalicznego, zwiazkow chromu: chrom (II) - w przeliczeniu na Cr (II), chromu III – w przeliczeniu na Cr (III) (z obliczen) PB-03 wydanie 1 z dnia 01.04.2021 r.","categories":["materials","environment"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration of metallic chromium, chromium compounds: chromium (II) - calculated as Cr (II), chromium III – calculated as Cr (III) (calculated)","search_en":"Workplace environment - air - air samples collected on filters Concentration of metallic chromium, chromium compounds: chromium (II) - calculated as Cr (II), chromium III – calculated as Cr (III) (calculated) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PB-03 wydanie 1 z dnia 01.04.2021 r.","test_object_en":"Workplace environment - air - air samples collected on filters","search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. PB-03 wydanie 1 z dnia 01.04.2021 r.","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bffb","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość cyny i jej związków nieorganicznych, z wyjątkiem stannanu – w przeliczeniu na Sn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,17 - 4,2) mg/m3"},{"name":"Zakres","range":"(125 - 3024) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość cyny i jej związków nieorganicznych, z wyjątkiem stannanu – w przeliczeniu na Sn\nZakres:\nfrakcja wdychalna\nZakres (0,17 - 4,2) mg/m3\nZakres (125 - 3024) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04488:2017-10","norm_bases":["PN-Z-04488:2017-10"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość cyny i jej związków nieorganicznych, z wyjątkiem stannanu – w przeliczeniu na Sn\nZakres:\nfrakcja wdychalna\nZakres (0,17 - 4,2) mg/m3\nZakres (125 - 3024) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04488:2017-10 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc cyny i jej zwiazkow nieorganicznych, z wyjatkiem stannanu – w przeliczeniu na Sn\nZakres:\nfrakcja wdychalna\nZakres (0,17 - 4,2) mg/m3\nZakres (125 - 3024) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04488:2017-10","categories":["environment"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of tin and its inorganic compounds, except stannane – calculated as Sn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,17 - 4,2) mg/m3"},{"name":"Range","range":"(125 - 3024) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of tin and its inorganic compounds, except stannane – calculated as Sn Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. inhalable fraction Range Range PN-Z-04488:2017-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,17 - 4,2) mg/m3"},{"name":"范围","range":"(125 - 3024) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 可吸入组分 范围 范围 PN-Z-04488:2017-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bffc","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość tlenku cynku w przeliczeniu na Zn","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,003 - 20) mg/m3"},{"name":"Zakres","range":"(2,1 - 14400) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość tlenku cynku w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (0,003 - 20) mg/m3\nZakres (2,1 - 14400) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-87/Z-04100/03","norm_bases":["PN-87/Z-04100/03"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość tlenku cynku w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (0,003 - 20) mg/m3\nZakres (2,1 - 14400) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-87/Z-04100/03 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc tlenku cynku w przeliczeniu na Zn\nZakres:\nfrakcja wdychalna\nZakres (0,003 - 20) mg/m3\nZakres (2,1 - 14400) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-87/Z-04100/03","categories":["environment"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of zinc oxide calculated as Zn","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,003 - 20) mg/m3"},{"name":"Range","range":"(2,1 - 14400) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of zinc oxide calculated as Zn Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. inhalable fraction Range Range PN-87/Z-04100/03","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,003 - 20) mg/m3"},{"name":"范围","range":"(2,1 - 14400) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 可吸入组分 范围 范围 PN-87/Z-04100/03","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41bffd","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość kadmu i jego związków nieorganicznych – w przeliczeniu na Cd","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,0001 - 0,013) mg/m3"},{"name":"Zakres","range":"(0,15 - 15,0) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość kadmu i jego związków nieorganicznych – w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,0001 - 0,013) mg/m3\nZakres (0,15 - 15,0) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04102-3:2013","norm_bases":["PN-Z-04102-3:2013"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość kadmu i jego związków nieorganicznych – w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,0001 - 0,013) mg/m3\nZakres (0,15 - 15,0) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04102-3:2013 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc kadmu i jego zwiazkow nieorganicznych – w przeliczeniu na Cd\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,0001 - 0,013) mg/m3\nZakres (0,15 - 15,0) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04102-3:2013","categories":["environment"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of cadmium and its inorganic compounds – calculated as Cd","parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(0,0001 - 0,013) mg/m3"},{"name":"Range","range":"(0,15 - 15,0) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of cadmium and its inorganic compounds – calculated as Cd Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. inhalable fraction respirable fraction Range Range PN-Z-04102-3:2013","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,0001 - 0,013) mg/m3"},{"name":"范围","range":"(0,15 - 15,0) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 镉及其无机化合物的浓度/含量 － 以 Cd 计 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 可吸入组分 呼吸性组分 范围 范围 PN-Z-04102-3:2013","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"镉及其无机化合物的浓度/含量 － 以 Cd 计"},{"_id":"6a7d7be00636ba417e41bffe","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość kobaltu i jego związków nieorganicznych – w przeliczeniu na Co","parameters":[{"name":"Zakres","range":"(0,002 - 0,4) mg/m3"},{"name":"Zakres","range":"(1,0 - 288) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość kobaltu i jego związków nieorganicznych – w przeliczeniu na Co\nZakres:\nZakres (0,002 - 0,4) mg/m3\nZakres (1,0 - 288) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04291:2003","norm_bases":["PN-Z-04291:2003"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość kobaltu i jego związków nieorganicznych – w przeliczeniu na Co\nZakres:\nZakres (0,002 - 0,4) mg/m3\nZakres (1,0 - 288) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04291:2003 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc kobaltu i jego zwiazkow nieorganicznych – w przeliczeniu na Co\nZakres:\nZakres (0,002 - 0,4) mg/m3\nZakres (1,0 - 288) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04291:2003","categories":["environment"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of cobalt and its inorganic compounds – calculated as Co","parameters_en":[{"name":"Range","range":"(0,002 - 0,4) mg/m3"},{"name":"Range","range":"(1,0 - 288) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of cobalt and its inorganic compounds – calculated as Co Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04291:2003","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,002 - 0,4) mg/m3"},{"name":"范围","range":"(1,0 - 288) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 钴及其无机化合物的浓度/含量 － 以 Co 计 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04291:2003","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"钴及其无机化合物的浓度/含量 － 以 Co 计"},{"_id":"6a7d7be00636ba417e41bfff","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość manganu i jego związków nieorganicznych - w przeliczeniu na Mn","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,005 - 0,6) mg/m3"},{"name":"Zakres","range":"(3,6 - 432) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość manganu i jego związków nieorganicznych - w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,005 - 0,6) mg/m3\nZakres (3,6 - 432) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04472:2015-10+Ap1:2015-12","norm_bases":["PN-Z-04472:2015-10+Ap1:2015-12"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość manganu i jego związków nieorganicznych - w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,005 - 0,6) mg/m3\nZakres (3,6 - 432) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10+Ap1:2015-12 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc manganu i jego zwiazkow nieorganicznych - w przeliczeniu na Mn\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,005 - 0,6) mg/m3\nZakres (3,6 - 432) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04472:2015-10+Ap1:2015-12","categories":["environment"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of manganese and its inorganic compounds - calculated as Mn","parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(0,005 - 0,6) mg/m3"},{"name":"Range","range":"(3,6 - 432) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of manganese and its inorganic compounds - calculated as Mn Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. inhalable fraction respirable fraction Range Range PN-Z-04472:2015-10+Ap1:2015-12","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,005 - 0,6) mg/m3"},{"name":"范围","range":"(3,6 - 432) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 可吸入组分 呼吸性组分 范围 范围 PN-Z-04472:2015-10+Ap1:2015-12","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41c000","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość miedzi i jej związków nieorganicznych – w przeliczeniu na Cu","parameters":[{"name":"Zakres","range":"(0,007 - 0,6) mg/m3"},{"name":"Zakres","range":"(5 - 432) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość miedzi i jej związków nieorganicznych – w przeliczeniu na Cu\nZakres:\nZakres (0,007 - 0,6) mg/m3\nZakres (5 - 432) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04106-3:2002","norm_bases":["PN-Z-04106-3:2002"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość miedzi i jej związków nieorganicznych – w przeliczeniu na Cu\nZakres:\nZakres (0,007 - 0,6) mg/m3\nZakres (5 - 432) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04106-3:2002 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc miedzi i jej zwiazkow nieorganicznych – w przeliczeniu na Cu\nZakres:\nZakres (0,007 - 0,6) mg/m3\nZakres (5 - 432) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04106-3:2002","categories":["environment"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of copper and its inorganic compounds – calculated as Cu","parameters_en":[{"name":"Range","range":"(0,007 - 0,6) mg/m3"},{"name":"Range","range":"(5 - 432) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of copper and its inorganic compounds – calculated as Cu Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04106-3:2002","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,007 - 0,6) mg/m3"},{"name":"范围","range":"(5 - 432) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 铜及其无机化合物的浓度/含量 － 以 Cu 计 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04106-3:2002","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"铜及其无机化合物的浓度/含量 － 以 Cu 计"},{"_id":"6a7d7be00636ba417e41c001","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość niklu metalicznego","parameters":[{"name":"Zakres","range":"(0,015 - 0,58) mg/m3"},{"name":"Zakres","range":"(10,47 - 418,8) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość niklu metalicznego\nZakres:\nZakres (0,015 - 0,58) mg/m3\nZakres (10,47 - 418,8) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04502:2019-10","norm_bases":["PN-Z-04502:2019-10"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość niklu metalicznego\nZakres:\nZakres (0,015 - 0,58) mg/m3\nZakres (10,47 - 418,8) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc niklu metalicznego\nZakres:\nZakres (0,015 - 0,58) mg/m3\nZakres (10,47 - 418,8) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10","categories":["materials","environment"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Metallic nickel concentration/content","parameters_en":[{"name":"Range","range":"(0,015 - 0,58) mg/m3"},{"name":"Range","range":"(10,47 - 418,8) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Metallic nickel concentration/content Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04502:2019-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,015 - 0,58) mg/m3"},{"name":"范围","range":"(10,47 - 418,8) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 金属镍的浓度/含量 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04502:2019-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"金属镍的浓度/含量"},{"_id":"6a7d7be00636ba417e41c002","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość związków niklu – w przeliczeniu na Ni","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0013 - 0,13) mg/m3"},{"name":"Zakres","range":"(0,96 - 96,0) μg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,00089 - 0,089) mg/m3"},{"name":"Zakres","range":"(0,96 - 96,0) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość związków niklu – w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna\nZakres (0,0013 - 0,13) mg/m3\nZakres (0,96 - 96,0) μg w próbce\nfrakcja respirabilna\nZakres (0,00089 - 0,089) mg/m3\nZakres (0,96 - 96,0) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04502:2019-10 Podstawy i Metody Oceny Środowiska Pracy 2021, 4 (110), str. 179 - 189","norm_bases":["PN-Z-04502:2019-10 Podstawy i Metody Oceny Środowiska Pracy 2021, 4 (110), str. 179 - 189"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość związków niklu – w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna\nZakres (0,0013 - 0,13) mg/m3\nZakres (0,96 - 96,0) μg w próbce\nfrakcja respirabilna\nZakres (0,00089 - 0,089) mg/m3\nZakres (0,96 - 96,0) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10 Podstawy i Metody Oceny Środowiska Pracy 2021, 4 (110), str. 179 - 189 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc zwiazkow niklu – w przeliczeniu na Ni\nZakres:\nfrakcja wdychalna\nZakres (0,0013 - 0,13) mg/m3\nZakres (0,96 - 96,0) μg w probce\nfrakcja respirabilna\nZakres (0,00089 - 0,089) mg/m3\nZakres (0,96 - 96,0) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04502:2019-10 Podstawy i Metody Oceny Srodowiska Pracy 2021, 4 (110), str. 179 - 189","categories":["environment"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of nickel compounds – calculated as Ni","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,0013 - 0,13) mg/m3"},{"name":"Range","range":"(0,96 - 96,0) μg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,00089 - 0,089) mg/m3"},{"name":"Range","range":"(0,96 - 96,0) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of nickel compounds – calculated as Ni Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. inhalable fraction Range Range respirable fraction Range Range PN-Z-04502:2019-10 Podstawy i Metody Oceny Środowiska Pracy 2021, 4 (110), str. 179 - 189","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,0013 - 0,13) mg/m3"},{"name":"范围","range":"(0,96 - 96,0) μg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,00089 - 0,089) mg/m3"},{"name":"范围","range":"(0,96 - 96,0) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 可吸入组分 范围 范围 呼吸性组分 范围 范围 PN-Z-04502:2019-10 Podstawy i Metody Oceny Środowiska Pracy 2021, 4 (110), str. 179 - 189","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41c003","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość ołowiu i jego związków nieorganicznych – w przeliczeniu na Pb","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,0035 - 0,142) mg/m3"},{"name":"Zakres","range":"(2,6 - 102) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość ołowiu i jego związków nieorganicznych – w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (0,0035 - 0,142) mg/m3\nZakres (2,6 - 102) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04487:2017-10","norm_bases":["PN-Z-04487:2017-10"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość ołowiu i jego związków nieorganicznych – w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (0,0035 - 0,142) mg/m3\nZakres (2,6 - 102) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04487:2017-10 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc olowiu i jego zwiazkow nieorganicznych – w przeliczeniu na Pb\nZakres:\nfrakcja wdychalna\nZakres (0,0035 - 0,142) mg/m3\nZakres (2,6 - 102) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04487:2017-10","categories":["environment"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of lead and its inorganic compounds – calculated as Pb","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,0035 - 0,142) mg/m3"},{"name":"Range","range":"(2,6 - 102) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of lead and its inorganic compounds – calculated as Pb Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. inhalable fraction Range Range PN-Z-04487:2017-10","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,0035 - 0,142) mg/m3"},{"name":"范围","range":"(2,6 - 102) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 可吸入组分 范围 范围 PN-Z-04487:2017-10","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41c004","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość srebra. Srebra związki rozpuszczalne w przeliczeniu na Ag","parameters":[{"name":"Zakres","range":"(0,0010 - 0,12) mg/m3"},{"name":"Zakres","range":"(0,75 - 86,40) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość srebra. Srebra związki rozpuszczalne w przeliczeniu na Ag\nZakres:\nZakres (0,0010 - 0,12) mg/m3\nZakres (0,75 - 86,40) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"Podstawy i Metody Oceny Środowiska Pracy 1998, Zeszyt nr 19","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 1998, Zeszyt nr 19"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość srebra. Srebra związki rozpuszczalne w przeliczeniu na Ag\nZakres:\nZakres (0,0010 - 0,12) mg/m3\nZakres (0,75 - 86,40) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) Podstawy i Metody Oceny Środowiska Pracy 1998, Zeszyt nr 19 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc srebra. Srebra zwiazki rozpuszczalne w przeliczeniu na Ag\nZakres:\nZakres (0,0010 - 0,12) mg/m3\nZakres (0,75 - 86,40) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) Podstawy i Metody Oceny Srodowiska Pracy 1998, Zeszyt nr 19","categories":["environment"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Silver concentration/content. Soluble silver compounds calculated as Ag","parameters_en":[{"name":"Range","range":"(0,0010 - 0,12) mg/m3"},{"name":"Range","range":"(0,75 - 86,40) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Silver concentration/content. Soluble silver compounds calculated as Ag Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range Podstawy i Metody Oceny Środowiska Pracy 1998, Zeszyt nr 19","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,0010 - 0,12) mg/m3"},{"name":"范围","range":"(0,75 - 86,40) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 1998, Zeszyt nr 19","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41c005","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość srebra – frakcja wdychalna, srebra związki nierozpuszczalne – w przeliczeniu na Ag","parameters":[{"name":"Zakres","range":"(0,003 - 0,1) mg/m3"},{"name":"Zakres","range":"(2,0 - 72,0) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość srebra – frakcja wdychalna, srebra związki nierozpuszczalne – w przeliczeniu na Ag\nZakres:\nZakres (0,003 - 0,1) mg/m3\nZakres (2,0 - 72,0) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04216-2:2012","norm_bases":["PN-Z-04216-2:2012"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość srebra – frakcja wdychalna, srebra związki nierozpuszczalne – w przeliczeniu na Ag\nZakres:\nZakres (0,003 - 0,1) mg/m3\nZakres (2,0 - 72,0) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04216-2:2012 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc srebra – frakcja wdychalna, srebra zwiazki nierozpuszczalne – w przeliczeniu na Ag\nZakres:\nZakres (0,003 - 0,1) mg/m3\nZakres (2,0 - 72,0) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04216-2:2012","categories":["environment"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of silver – inhalable fraction, insoluble silver compounds – calculated as Ag","parameters_en":[{"name":"Range","range":"(0,003 - 0,1) mg/m3"},{"name":"Range","range":"(2,0 - 72,0) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of silver – inhalable fraction, insoluble silver compounds – calculated as Ag Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04216-2:2012","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,003 - 0,1) mg/m3"},{"name":"范围","range":"(2,0 - 72,0) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04216-2:2012","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41c006","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza (III) tlenek żelaza (II) tetratlenek triżelaza – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,34 - 49,4) mg/m3"},{"name":"Zakres","range":"(49,4 - 7403,8) μg w próbce"},{"name":"– frakcja respirabilna"},{"name":"Zakres","range":"(0,19 - 44,9) mg/m3"},{"name":"Zakres","range":"(49,4 - 4627,3) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza (III) tlenek żelaza (II) tetratlenek triżelaza – frakcja wdychalna\nZakres:\nZakres (0,34 - 49,4) mg/m3\nZakres (49,4 - 7403,8) μg w próbce\n– frakcja respirabilna\nZakres (0,19 - 44,9) mg/m3\nZakres (49,4 - 4627,3) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04469:2025-02","norm_bases":["PN-Z-04469:2025-02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość tlenków żelaza w przeliczeniu na Fe tlenek żelaza (III) tlenek żelaza (II) tetratlenek triżelaza – frakcja wdychalna\nZakres:\nZakres (0,34 - 49,4) mg/m3\nZakres (49,4 - 7403,8) μg w próbce\n– frakcja respirabilna\nZakres (0,19 - 44,9) mg/m3\nZakres (49,4 - 4627,3) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc tlenkow zelaza w przeliczeniu na Fe tlenek zelaza (III) tlenek zelaza (II) tetratlenek trizelaza – frakcja wdychalna\nZakres:\nZakres (0,34 - 49,4) mg/m3\nZakres (49,4 - 7403,8) μg w probce\n– frakcja respirabilna\nZakres (0,19 - 44,9) mg/m3\nZakres (49,4 - 4627,3) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04469:2025-02","categories":["environment"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of iron oxides calculated as Fe iron(III) oxide iron(II) oxide triiron tetraoxide – inhalable fraction","parameters_en":[{"name":"Range","range":"(0,34 - 49,4) mg/m3"},{"name":"Range","range":"(49,4 - 7403,8) μg w próbce"},{"name":"– respirable fraction"},{"name":"Range","range":"(0,19 - 44,9) mg/m3"},{"name":"Range","range":"(49,4 - 4627,3) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of iron oxides calculated as Fe iron(III) oxide iron(II) oxide triiron tetraoxide – inhalable fraction Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range – respirable fraction Range Range PN-Z-04469:2025-02","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,34 - 49,4) mg/m3"},{"name":"范围","range":"(49,4 - 7403,8) μg w próbce"},{"name":"— 呼吸性组分"},{"name":"范围","range":"(0,19 - 44,9) mg/m3"},{"name":"范围","range":"(49,4 - 4627,3) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 — 呼吸性组分 范围 范围 PN-Z-04469:2025-02","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41c007","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość wodorotlenku sodu","parameters":[{"name":"Zakres","range":"(0,012 - 2) mg/m3"},{"name":"Zakres","range":"(4,5 - 720) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość wodorotlenku sodu\nZakres:\nZakres (0,012 - 2) mg/m3\nZakres (4,5 - 720) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04435:2011","norm_bases":["PN-Z-04435:2011"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość wodorotlenku sodu\nZakres:\nZakres (0,012 - 2) mg/m3\nZakres (4,5 - 720) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04435:2011 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc wodorotlenku sodu\nZakres:\nZakres (0,012 - 2) mg/m3\nZakres (4,5 - 720) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04435:2011","categories":["environment"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Sodium hydroxide concentration/content","parameters_en":[{"name":"Range","range":"(0,012 - 2) mg/m3"},{"name":"Range","range":"(4,5 - 720) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Sodium hydroxide concentration/content Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04435:2011","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,012 - 2) mg/m3"},{"name":"范围","range":"(4,5 - 720) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 氢氧化钠的浓度/含量 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04435:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"氢氧化钠的浓度/含量"},{"_id":"6a7d7be00636ba417e41c008","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość wodorotlenku potasu","parameters":[{"name":"Zakres","range":"(0,02 - 7) mg/m3"},{"name":"Zakres","range":"(14 - 215) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość wodorotlenku potasu\nZakres:\nZakres (0,02 - 7) mg/m3\nZakres (14 - 215) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04436:2011","norm_bases":["PN-Z-04436:2011"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość wodorotlenku potasu\nZakres:\nZakres (0,02 - 7) mg/m3\nZakres (14 - 215) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04436:2011 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc wodorotlenku potasu\nZakres:\nZakres (0,02 - 7) mg/m3\nZakres (14 - 215) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04436:2011","categories":["environment"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Potassium hydroxide concentration/content","parameters_en":[{"name":"Range","range":"(0,02 - 7) mg/m3"},{"name":"Range","range":"(14 - 215) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Potassium hydroxide concentration/content Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04436:2011","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,02 - 7) mg/m3"},{"name":"范围","range":"(14 - 215) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 氢氧化钾的浓度/含量 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04436:2011","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"氢氧化钾的浓度/含量"},{"_id":"6a7d7be00636ba417e41c009","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość wodorotlenku wapnia","parameters":[{"name":"frakcja wdychalna"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,06 - 12) mg/m3"},{"name":"Zakres","range":"(46 - 2958) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość wodorotlenku wapnia\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,06 - 12) mg/m3\nZakres (46 - 2958) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04497:2018-09","norm_bases":["PN-Z-04497:2018-09"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość wodorotlenku wapnia\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,06 - 12) mg/m3\nZakres (46 - 2958) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04497:2018-09 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc wodorotlenku wapnia\nZakres:\nfrakcja wdychalna\nfrakcja respirabilna\nZakres (0,06 - 12) mg/m3\nZakres (46 - 2958) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04497:2018-09","categories":["environment"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of calcium hydroxide","parameters_en":[{"name":"inhalable fraction"},{"name":"respirable fraction"},{"name":"Range","range":"(0,06 - 12) mg/m3"},{"name":"Range","range":"(46 - 2958) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of calcium hydroxide Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. inhalable fraction respirable fraction Range Range PN-Z-04497:2018-09","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,06 - 12) mg/m3"},{"name":"范围","range":"(46 - 2958) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 可吸入组分 呼吸性组分 范围 范围 PN-Z-04497:2018-09","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41c00a","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość tlenku wapnia","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,1 - 119,7) mg/m3"},{"name":"Zakres","range":"(71,8 - 3590,9) μg w próbce"},{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,091 - 108,8) mg/m3"},{"name":"Zakres","range":"(71,8 - 3590,9) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość tlenku wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,1 - 119,7) mg/m3\nZakres (71,8 - 3590,9) μg w próbce\nfrakcja respirabilna\nZakres (0,091 - 108,8) mg/m3\nZakres (71,8 - 3590,9) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04442:2023-05","norm_bases":["PN-Z-04442:2023-05"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość tlenku wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,1 - 119,7) mg/m3\nZakres (71,8 - 3590,9) μg w próbce\nfrakcja respirabilna\nZakres (0,091 - 108,8) mg/m3\nZakres (71,8 - 3590,9) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04442:2023-05 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc tlenku wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,1 - 119,7) mg/m3\nZakres (71,8 - 3590,9) μg w probce\nfrakcja respirabilna\nZakres (0,091 - 108,8) mg/m3\nZakres (71,8 - 3590,9) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04442:2023-05","categories":["environment"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Calcium oxide concentration/content","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,1 - 119,7) mg/m3"},{"name":"Range","range":"(71,8 - 3590,9) μg w próbce"},{"name":"respirable fraction"},{"name":"Range","range":"(0,091 - 108,8) mg/m3"},{"name":"Range","range":"(71,8 - 3590,9) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Calcium oxide concentration/content Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. inhalable fraction Range Range respirable fraction Range Range PN-Z-04442:2023-05","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,1 - 119,7) mg/m3"},{"name":"范围","range":"(71,8 - 3590,9) μg w próbce"},{"name":"呼吸性组分"},{"name":"范围","range":"(0,091 - 108,8) mg/m3"},{"name":"范围","range":"(71,8 - 3590,9) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 氧化钙的浓度/含量 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 可吸入组分 范围 范围 呼吸性组分 范围 范围 PN-Z-04442:2023-05","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"氧化钙的浓度/含量"},{"_id":"6a7d7be00636ba417e41c00b","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość węglanu wapnia","parameters":[{"name":"frakcja wdychalna"},{"name":"Zakres","range":"(0,67 - 20,15) mg/m3"},{"name":"Zakres","range":"(498 - 14940) μg w próbce"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie/zawartość węglanu wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,67 - 20,15) mg/m3\nZakres (498 - 14940) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-Z-04294:2001","norm_bases":["PN-Z-04294:2001"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość węglanu wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,67 - 20,15) mg/m3\nZakres (498 - 14940) μg w próbce\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04294:2001 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc weglanu wapnia\nZakres:\nfrakcja wdychalna\nZakres (0,67 - 20,15) mg/m3\nZakres (498 - 14940) μg w probce\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-Z-04294:2001","categories":["environment"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of calcium carbonate","parameters_en":[{"name":"inhalable fraction"},{"name":"Range","range":"(0,67 - 20,15) mg/m3"},{"name":"Range","range":"(498 - 14940) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of calcium carbonate Flame atomic absorption spectrometry (FAAS) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. inhalable fraction Range Range PN-Z-04294:2001","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"可吸入组分"},{"name":"范围","range":"(0,67 - 20,15) mg/m3"},{"name":"范围","range":"(498 - 14940) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 火焰原子吸收光谱法（FAAS） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 可吸入组分 范围 范围 PN-Z-04294:2001","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41c00c","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość oleju mineralnego wysokorafinowanego – z wyłączeniem cieczy obróbkowych – frakcja wdychalna","parameters":[{"name":"Zakres","range":"(0,3 - 20) mg/m3"},{"name":"Zakres","range":"(0,2 - 14,4) mg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR)","techniques":["Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR)"],"computed":[],"activity":"Stężenie/zawartość oleju mineralnego wysokorafinowanego – z wyłączeniem cieczy obróbkowych – frakcja wdychalna\nZakres:\nZakres (0,3 - 20) mg/m3\nZakres (0,2 - 14,4) mg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR)","reference":"PN-Z-04108-5:2006","norm_bases":["PN-Z-04108-5:2006"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość oleju mineralnego wysokorafinowanego – z wyłączeniem cieczy obróbkowych – frakcja wdychalna\nZakres:\nZakres (0,3 - 20) mg/m3\nZakres (0,2 - 14,4) mg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR) PN-Z-04108-5:2006 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc oleju mineralnego wysokorafinowanego – z wylaczeniem cieczy obrobkowych – frakcja wdychalna\nZakres:\nZakres (0,3 - 20) mg/m3\nZakres (0,2 - 14,4) mg w probce\nMetoda spektrometrii w podczerwieni z transformacja Fouriera (FT- IR) PN-Z-04108-5:2006","categories":["environment","petro"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of highly refined mineral oil – excluding metalworking fluids – inhalable fraction","parameters_en":[{"name":"Range","range":"(0,3 - 20) mg/m3"},{"name":"Range","range":"(0,2 - 14,4) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of highly refined mineral oil – excluding metalworking fluids – inhalable fraction Fourier transform infrared spectrometry (FT- IR) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04108-5:2006","technique_en":"Fourier transform infrared spectrometry (FT- IR)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,3 - 20) mg/m3"},{"name":"范围","range":"(0,2 - 14,4) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 傅里叶变换红外光谱法（FT-IR） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04108-5:2006","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a7d7be00636ba417e41c00d","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość krzemionki krystalicznej (kwarc i krystobalit)","parameters":[{"name":"frakcja respirabilna"},{"name":"Zakres","range":"(0,005 - 0,73) mg/m3"},{"name":"Zakres","range":"(5,0 - 500) μg w próbce"}],"technique":"Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR)","techniques":["Metoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR)"],"computed":[],"activity":"Stężenie/zawartość krzemionki krystalicznej (kwarc i krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,005 - 0,73) mg/m3\nZakres (5,0 - 500) μg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość krzemionki krystalicznej (kwarc i krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,005 - 0,73) mg/m3\nZakres (5,0 - 500) μg w próbce\nMetoda spektrometrii w podczerwieni z transformacją Fouriera (FT- IR) Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc krzemionki krystalicznej (kwarc i krystobalit)\nZakres:\nfrakcja respirabilna\nZakres (0,005 - 0,73) mg/m3\nZakres (5,0 - 500) μg w probce\nMetoda spektrometrii w podczerwieni z transformacja Fouriera (FT- IR) Podstawy i Metody Oceny Srodowiska Pracy 2012, 4 (74), str. 117-130","categories":["environment"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of crystalline silica (quartz and cristobalite)","parameters_en":[{"name":"respirable fraction"},{"name":"Range","range":"(0,005 - 0,73) mg/m3"},{"name":"Range","range":"(5,0 - 500) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Concentration/content of crystalline silica (quartz and cristobalite) Fourier transform infrared spectrometry (FT- IR) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. respirable fraction Range Range Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","technique_en":"Fourier transform infrared spectrometry (FT- IR)","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"呼吸性组分"},{"name":"范围","range":"(0,005 - 0,73) mg/m3"},{"name":"范围","range":"(5,0 - 500) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 傅里叶变换红外光谱法（FT-IR） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 呼吸性组分 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2012, 4 (74), str. 117-130","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","technique_zh":"傅里叶变换红外光谱法（FT-IR）"},{"_id":"6a7d7be00636ba417e41c00e","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry","methodology":"Stężenie/zawartość chlorowodoru","parameters":[{"name":"Zakres","range":"(0,39 - 137) mg/m3"},{"name":"Zakres","range":"(154 - 4110) μg w próbce"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,39 - 137) mg/m3\nZakres (154 - 4110) μg w próbce\nMetoda turbidymetryczna","reference":"PN-Z-04450:2014-08","norm_bases":["PN-Z-04450:2014-08"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na filtry Stężenie/zawartość chlorowodoru\nZakres:\nZakres (0,39 - 137) mg/m3\nZakres (154 - 4110) μg w próbce\nMetoda turbidymetryczna PN-Z-04450:2014-08 Srodowisko pracy - powietrze - probki powietrza pobrane na filtry Stezenie/zawartosc chlorowodoru\nZakres:\nZakres (0,39 - 137) mg/m3\nZakres (154 - 4110) μg w probce\nMetoda turbidymetryczna PN-Z-04450:2014-08","categories":["environment"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Hydrogen chloride concentration/content","parameters_en":[{"name":"Range","range":"(0,39 - 137) mg/m3"},{"name":"Range","range":"(154 - 4110) μg w próbce"}],"search_en":"Workplace environment - air - air samples collected on filters Hydrogen chloride concentration/content Turbidimetric method „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04450:2014-08","technique_en":"Turbidimetric method","test_object_en":"Workplace environment - air - air samples collected on filters","parameters_zh":[{"name":"范围","range":"(0,39 - 137) mg/m3"},{"name":"范围","range":"(154 - 4110) μg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品 氯化氢的浓度/含量 浊度法 „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04450:2014-08","test_object_zh":"工作场所环境 — 空气 — 用滤膜采集的空气样品","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","technique_zh":"浊度法","methodology_zh":"氯化氢的浓度/含量"},{"_id":"6a7d7be00636ba417e41c00f","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość acetonu","parameters":[{"name":"Zakres","range":"(48 - 3600) mg/m3"},{"name":"Zakres","range":"(0,15 - 3,95) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość acetonu\nZakres:\nZakres (48 - 3600) mg/m3\nZakres (0,15 - 3,95) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023/02","norm_bases":["PN-89/Z-04023/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość acetonu\nZakres:\nZakres (48 - 3600) mg/m3\nZakres (0,15 - 3,95) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc acetonu\nZakres:\nZakres (48 - 3600) mg/m3\nZakres (0,15 - 3,95) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023/02","categories":["environment"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Acetone concentration/content","parameters_en":[{"name":"Range","range":"(48 - 3600) mg/m3"},{"name":"Range","range":"(0,15 - 3,95) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Acetone concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-89/Z-04023/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(48 - 3600) mg/m3"},{"name":"范围","range":"(0,15 - 3,95) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 丙酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-89/Z-04023/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"丙酮的浓度/含量"},{"_id":"6a7d7be00636ba417e41c010","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość benzenu","parameters":[{"name":"Zakres","range":"(0,063 - 3,05) mg/m3"},{"name":"Zakres","range":"(0,019 - 0,94) ppm"},{"name":"Zakres","range":"(0,0006 - 0,029) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość benzenu\nZakres:\nZakres (0,063 - 3,05) mg/m3\nZakres (0,019 - 0,94) ppm\nZakres (0,0006 - 0,029) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04016-10:2005","norm_bases":["PN-Z-04016-10:2005"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość benzenu\nZakres:\nZakres (0,063 - 3,05) mg/m3\nZakres (0,019 - 0,94) ppm\nZakres (0,0006 - 0,029) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04016-10:2005 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc benzenu\nZakres:\nZakres (0,063 - 3,05) mg/m3\nZakres (0,019 - 0,94) ppm\nZakres (0,0006 - 0,029) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04016-10:2005","categories":["environment"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Benzene concentration/content","parameters_en":[{"name":"Range","range":"(0,063 - 3,05) mg/m3"},{"name":"Range","range":"(0,019 - 0,94) ppm"},{"name":"Range","range":"(0,0006 - 0,029) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Benzene concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range Range PN-Z-04016-10:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(0,063 - 3,05) mg/m3"},{"name":"范围","range":"(0,019 - 0,94) ppm"},{"name":"范围","range":"(0,0006 - 0,029) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 范围 PN-Z-04016-10:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"苯的浓度/含量"},{"_id":"6a7d7be00636ba417e41c011","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość benzyny ekstrakcyjnej","parameters":[{"name":"Zakres","range":"(36 - 3000) mg/m3"},{"name":"Zakres","range":"(0,2 - 19,7) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (36 - 3000) mg/m3\nZakres (0,2 - 19,7) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-81/Z-04134/02","norm_bases":["PN-81/Z-04134/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość benzyny ekstrakcyjnej\nZakres:\nZakres (36 - 3000) mg/m3\nZakres (0,2 - 19,7) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-81/Z-04134/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc benzyny ekstrakcyjnej\nZakres:\nZakres (36 - 3000) mg/m3\nZakres (0,2 - 19,7) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-81/Z-04134/02","categories":["environment"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Extraction naphtha concentration/content","parameters_en":[{"name":"Range","range":"(36 - 3000) mg/m3"},{"name":"Range","range":"(0,2 - 19,7) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Extraction naphtha concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-81/Z-04134/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(36 - 3000) mg/m3"},{"name":"范围","range":"(0,2 - 19,7) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 抽提汽油的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-81/Z-04134/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"抽提汽油的浓度/含量"},{"_id":"6a7d7be00636ba417e41c012","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość benzyny do lakierów","parameters":[{"name":"Zakres","range":"(24 - 1800) mg/m3"},{"name":"Zakres","range":"(0,36 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość benzyny do lakierów\nZakres:\nZakres (24 - 1800) mg/m3\nZakres (0,36 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-81/Z-04134/03","norm_bases":["PN-81/Z-04134/03"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość benzyny do lakierów\nZakres:\nZakres (24 - 1800) mg/m3\nZakres (0,36 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-81/Z-04134/03 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc benzyny do lakierow\nZakres:\nZakres (24 - 1800) mg/m3\nZakres (0,36 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-81/Z-04134/03","categories":["environment","automotive"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"White spirit concentration/content","parameters_en":[{"name":"Range","range":"(24 - 1800) mg/m3"},{"name":"Range","range":"(0,36 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes White spirit concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-81/Z-04134/03","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(24 - 1800) mg/m3"},{"name":"范围","range":"(0,36 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 油漆用溶剂汽油的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-81/Z-04134/03","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"油漆用溶剂汽油的浓度/含量"},{"_id":"6a7d7be00636ba417e41c013","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość 2-bromo-2-chloro-1,1,1-trifluoroetanu (halotanu)","parameters":[{"name":"Zakres","range":"(0,5 - 200) mg/m3"},{"name":"Zakres","range":"(0,009 - 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-bromo-2-chloro-1,1,1-trifluoroetanu (halotanu)\nZakres:\nZakres (0,5 - 200) mg/m3\nZakres (0,009 - 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-92/Z-04223/02","norm_bases":["PN-92/Z-04223/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość 2-bromo-2-chloro-1,1,1-trifluoroetanu (halotanu)\nZakres:\nZakres (0,5 - 200) mg/m3\nZakres (0,009 - 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-92/Z-04223/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc 2-bromo-2-chloro-1,1,1-trifluoroetanu (halotanu)\nZakres:\nZakres (0,5 - 200) mg/m3\nZakres (0,009 - 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-92/Z-04223/02","categories":["environment"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of 2-bromo-2-chloro-1,1,1-trifluoroethane (halothane)","parameters_en":[{"name":"Range","range":"(0,5 - 200) mg/m3"},{"name":"Range","range":"(0,009 - 2,0) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of 2-bromo-2-chloro-1,1,1-trifluoroethane (halothane) Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-92/Z-04223/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(0,5 - 200) mg/m3"},{"name":"范围","range":"(0,009 - 2,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-92/Z-04223/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品"},{"_id":"6a7d7be00636ba417e41c014","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość butan-1-olu (alkoholu n-butylowego)","parameters":[{"name":"Zakres","range":"(4,5 - 300) mg/m3"},{"name":"Zakres","range":"(0,078 - 1,95) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość butan-1-olu (alkoholu n-butylowego)\nZakres:\nZakres (4,5 - 300) mg/m3\nZakres (0,078 - 1,95) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023/02","norm_bases":["PN-89/Z-04023/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość butan-1-olu (alkoholu n-butylowego)\nZakres:\nZakres (4,5 - 300) mg/m3\nZakres (0,078 - 1,95) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc butan-1-olu (alkoholu n-butylowego)\nZakres:\nZakres (4,5 - 300) mg/m3\nZakres (0,078 - 1,95) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023/02","categories":["environment"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of butan-1-ol (n-butyl alcohol)","parameters_en":[{"name":"Range","range":"(4,5 - 300) mg/m3"},{"name":"Range","range":"(0,078 - 1,95) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of butan-1-ol (n-butyl alcohol) Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-89/Z-04023/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(4,5 - 300) mg/m3"},{"name":"范围","range":"(0,078 - 1,95) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-89/Z-04023/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品"},{"_id":"6a7d7be00636ba417e41c015","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość butan-2-onu","parameters":[{"name":"Zakres","range":"(44 - 900) mg/m3"},{"name":"Zakres","range":"(0,49 - 9,8) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość butan-2-onu\nZakres:\nZakres (44 - 900) mg/m3\nZakres (0,49 - 9,8) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-79/Z-04107/02","norm_bases":["PN-79/Z-04107/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość butan-2-onu\nZakres:\nZakres (44 - 900) mg/m3\nZakres (0,49 - 9,8) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-79/Z-04107/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc butan-2-onu\nZakres:\nZakres (44 - 900) mg/m3\nZakres (0,49 - 9,8) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-79/Z-04107/02","categories":["environment"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of butan-2-one","parameters_en":[{"name":"Range","range":"(44 - 900) mg/m3"},{"name":"Range","range":"(0,49 - 9,8) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of butan-2-one Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-79/Z-04107/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(44 - 900) mg/m3"},{"name":"范围","range":"(0,49 - 9,8) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 丁酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-79/Z-04107/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"丁酮的浓度/含量"},{"_id":"6a7d7be00636ba417e41c016","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość 2-butoksyetanolu","parameters":[{"name":"Zakres","range":"(8,3 - 400) mg/m3"},{"name":"Zakres","range":"(0,15 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 2-butoksyetanolu\nZakres:\nZakres (8,3 - 400) mg/m3\nZakres (0,15 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023/02","norm_bases":["PN-89/Z-04023/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość 2-butoksyetanolu\nZakres:\nZakres (8,3 - 400) mg/m3\nZakres (0,15 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc 2-butoksyetanolu\nZakres:\nZakres (8,3 - 400) mg/m3\nZakres (0,15 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023/02","categories":["environment"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"2-butoxyethanol concentration/content","parameters_en":[{"name":"Range","range":"(8,3 - 400) mg/m3"},{"name":"Range","range":"(0,15 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes 2-butoxyethanol concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-89/Z-04023/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(8,3 - 400) mg/m3"},{"name":"范围","range":"(0,15 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 2-丁氧基乙醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-89/Z-04023/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"2-丁氧基乙醇的浓度/含量"},{"_id":"6a7d7be00636ba417e41c017","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość cykloheksanu","parameters":[{"name":"Zakres","range":"(30 - 2000) mg/m3"},{"name":"Zakres","range":"(0,38 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość cykloheksanu\nZakres:\nZakres (30 - 2000) mg/m3\nZakres (0,38 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-86/Z-04151/02","norm_bases":["PN-86/Z-04151/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość cykloheksanu\nZakres:\nZakres (30 - 2000) mg/m3\nZakres (0,38 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-86/Z-04151/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc cykloheksanu\nZakres:\nZakres (30 - 2000) mg/m3\nZakres (0,38 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-86/Z-04151/02","categories":["environment"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Cyclohexane concentration/content","parameters_en":[{"name":"Range","range":"(30 - 2000) mg/m3"},{"name":"Range","range":"(0,38 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Cyclohexane concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-86/Z-04151/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(30 - 2000) mg/m3"},{"name":"范围","range":"(0,38 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 环己烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-86/Z-04151/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"环己烷的浓度/含量"},{"_id":"6a7d7be00636ba417e41c018","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość cykloheksanonu","parameters":[{"name":"Zakres","range":"(4 - 160) mg/m3"},{"name":"Zakres","range":"(0,045 - 2,25) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość cykloheksanonu\nZakres:\nZakres (4 - 160) mg/m3\nZakres (0,045 - 2,25) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2007, Zeszyt nr 51","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2007, Zeszyt nr 51"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość cykloheksanonu\nZakres:\nZakres (4 - 160) mg/m3\nZakres (0,045 - 2,25) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2007, Zeszyt nr 51 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc cykloheksanonu\nZakres:\nZakres (4 - 160) mg/m3\nZakres (0,045 - 2,25) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2007, Zeszyt nr 51","categories":["environment"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Cyclohexanone concentration/content","parameters_en":[{"name":"Range","range":"(4 - 160) mg/m3"},{"name":"Range","range":"(0,045 - 2,25) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Cyclohexanone concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range Podstawy i Metody Oceny Środowiska Pracy 2007, Zeszyt nr 51","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(4 - 160) mg/m3"},{"name":"范围","range":"(0,045 - 2,25) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 环己酮的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2007, Zeszyt nr 51","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"环己酮的浓度/含量"},{"_id":"6a7d7be00636ba417e41c019","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość dichlorometanu","parameters":[{"name":"Zakres","range":"(6,6 - 746) mg/m3"},{"name":"Zakres","range":"(1,87 - 211,7) ppm"},{"name":"Zakres","range":"(0,065 - 4,7) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość dichlorometanu\nZakres:\nZakres (6,6 - 746) mg/m3\nZakres (1,87 - 211,7) ppm\nZakres (0,065 - 4,7) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04325:2006","norm_bases":["PN-Z-04325:2006"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość dichlorometanu\nZakres:\nZakres (6,6 - 746) mg/m3\nZakres (1,87 - 211,7) ppm\nZakres (0,065 - 4,7) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04325:2006 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc dichlorometanu\nZakres:\nZakres (6,6 - 746) mg/m3\nZakres (1,87 - 211,7) ppm\nZakres (0,065 - 4,7) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04325:2006","categories":["environment"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Dichloromethane concentration/content","parameters_en":[{"name":"Range","range":"(6,6 - 746) mg/m3"},{"name":"Range","range":"(1,87 - 211,7) ppm"},{"name":"Range","range":"(0,065 - 4,7) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Dichloromethane concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range Range PN-Z-04325:2006","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(6,6 - 746) mg/m3"},{"name":"范围","range":"(1,87 - 211,7) ppm"},{"name":"范围","range":"(0,065 - 4,7) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 二氯甲烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 范围 PN-Z-04325:2006","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"二氯甲烷的浓度/含量"},{"_id":"6a7d7be00636ba417e41c01a","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość etanolu","parameters":[{"name":"Zakres","range":"(114 - 3800) mg/m3"},{"name":"Zakres","range":"(0,38 - 11,8) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość etanolu\nZakres:\nZakres (114 - 3800) mg/m3\nZakres (0,38 - 11,8) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023/02","norm_bases":["PN-89/Z-04023/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość etanolu\nZakres:\nZakres (114 - 3800) mg/m3\nZakres (0,38 - 11,8) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc etanolu\nZakres:\nZakres (114 - 3800) mg/m3\nZakres (0,38 - 11,8) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023/02","categories":["environment"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Ethanol concentration/content","parameters_en":[{"name":"Range","range":"(114 - 3800) mg/m3"},{"name":"Range","range":"(0,38 - 11,8) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Ethanol concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-89/Z-04023/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(114 - 3800) mg/m3"},{"name":"范围","range":"(0,38 - 11,8) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 乙醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-89/Z-04023/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"乙醇的浓度/含量"},{"_id":"6a7d7be00636ba417e41c01b","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość eteru dietylowego","parameters":[{"name":"Zakres","range":"(26 - 3000) mg/m3"},{"name":"Zakres","range":"(0,35 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość eteru dietylowego\nZakres:\nZakres (26 - 3000) mg/m3\nZakres (0,35 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-86/Z-04158/02","norm_bases":["PN-86/Z-04158/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość eteru dietylowego\nZakres:\nZakres (26 - 3000) mg/m3\nZakres (0,35 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-86/Z-04158/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc eteru dietylowego\nZakres:\nZakres (26 - 3000) mg/m3\nZakres (0,35 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-86/Z-04158/02","categories":["environment"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of diethyl ether","parameters_en":[{"name":"Range","range":"(26 - 3000) mg/m3"},{"name":"Range","range":"(0,35 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of diethyl ether Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-86/Z-04158/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(26 - 3000) mg/m3"},{"name":"范围","range":"(0,35 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-86/Z-04158/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品"},{"_id":"6a7d7be00636ba417e41c01c","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość etylobenzenu","parameters":[{"name":"Zakres","range":"(8,4 - 700) mg/m3"},{"name":"Zakres","range":"(0,27 - 9,10) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość etylobenzenu\nZakres:\nZakres (8,4 - 700) mg/m3\nZakres (0,27 - 9,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-79/Z-04081/01","norm_bases":["PN-79/Z-04081/01"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość etylobenzenu\nZakres:\nZakres (8,4 - 700) mg/m3\nZakres (0,27 - 9,10) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-79/Z-04081/01 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc etylobenzenu\nZakres:\nZakres (8,4 - 700) mg/m3\nZakres (0,27 - 9,10) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-79/Z-04081/01","categories":["environment"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Ethylbenzene concentration/content","parameters_en":[{"name":"Range","range":"(8,4 - 700) mg/m3"},{"name":"Range","range":"(0,27 - 9,10) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Ethylbenzene concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-79/Z-04081/01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(8,4 - 700) mg/m3"},{"name":"范围","range":"(0,27 - 9,10) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 乙苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-79/Z-04081/01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"乙苯的浓度/含量"},{"_id":"6a7d7be00636ba417e41c01d","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość glikolu etylenowego","parameters":[{"name":"Zakres","range":"(1,3 - 100) mg/m3"},{"name":"Zakres","range":"(0,11 - 8) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (1,3 - 100) mg/m3\nZakres (0,11 - 8) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-88/Z-04203/02","norm_bases":["PN-88/Z-04203/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość glikolu etylenowego\nZakres:\nZakres (1,3 - 100) mg/m3\nZakres (0,11 - 8) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-88/Z-04203/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc glikolu etylenowego\nZakres:\nZakres (1,3 - 100) mg/m3\nZakres (0,11 - 8) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-88/Z-04203/02","categories":["environment"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Ethylene glycol concentration/content","parameters_en":[{"name":"Range","range":"(1,3 - 100) mg/m3"},{"name":"Range","range":"(0,11 - 8) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Ethylene glycol concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-88/Z-04203/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(1,3 - 100) mg/m3"},{"name":"范围","range":"(0,11 - 8) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 乙二醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-88/Z-04203/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"乙二醇的浓度/含量"},{"_id":"6a7d7be00636ba417e41c01e","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość izofluranu","parameters":[{"name":"Zakres","range":"(0,78 - 64) mg/m3"},{"name":"Zakres","range":"(0,056 - 1,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość izofluranu\nZakres:\nZakres (0,78 - 64) mg/m3\nZakres (0,056 - 1,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04423:2001","norm_bases":["PN-Z-04423:2001"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość izofluranu\nZakres:\nZakres (0,78 - 64) mg/m3\nZakres (0,056 - 1,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04423:2001 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc izofluranu\nZakres:\nZakres (0,78 - 64) mg/m3\nZakres (0,056 - 1,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04423:2001","categories":["environment"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Isoflurane concentration/content","parameters_en":[{"name":"Range","range":"(0,78 - 64) mg/m3"},{"name":"Range","range":"(0,056 - 1,2) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Isoflurane concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04423:2001","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(0,78 - 64) mg/m3"},{"name":"范围","range":"(0,056 - 1,2) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 异氟烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04423:2001","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"异氟烷的浓度/含量"},{"_id":"6a7d7be00636ba417e41c01f","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość ksylenu –","parameters":[{"name":"mieszaniny izomerów","range":"1,2-; 1,3-; 1,4-"},{"name":"Zakres","range":"(8,5 - 200) mg/m3"},{"name":"Zakres","range":"(0,09 - 17) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość ksylenu –\nZakres:\nmieszaniny izomerów 1,2-; 1,3-; 1,4-\nZakres (8,5 - 200) mg/m3\nZakres (0,09 - 17) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-89/Z-04023/02 | PB-14 wydanie 3 z dnia 10.06.2016 r.","norm_bases":["PN-89/Z-04023/02","PB-14 wydanie 3 z dnia 10.06.2016 r."],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość ksylenu –\nZakres:\nmieszaniny izomerów 1,2-; 1,3-; 1,4-\nZakres (8,5 - 200) mg/m3\nZakres (0,09 - 17) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-89/Z-04023/02 | PB-14 wydanie 3 z dnia 10.06.2016 r. Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc ksylenu –\nZakres:\nmieszaniny izomerow 1,2-; 1,3-; 1,4-\nZakres (8,5 - 200) mg/m3\nZakres (0,09 - 17) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-89/Z-04023/02 | PB-14 wydanie 3 z dnia 10.06.2016 r.","categories":["environment"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of xylene –","parameters_en":[{"name":"mixture of isomers","range":"1,2-; 1,3-; 1,4-"},{"name":"Range","range":"(8,5 - 200) mg/m3"},{"name":"Range","range":"(0,09 - 17) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of xylene – Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. mixture of isomers Range Range PN-89/Z-04023/02 | PB-14 wydanie 3 z dnia 10.06.2016 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"异构体混合物","range":"1,2-; 1,3-; 1,4-"},{"name":"范围","range":"(8,5 - 200) mg/m3"},{"name":"范围","range":"(0,09 - 17) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 异构体混合物 范围 范围 PN-89/Z-04023/02 | PB-14 wydanie 3 z dnia 10.06.2016 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品"},{"_id":"6a7d7be00636ba417e41c020","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość metanolu","parameters":[{"name":"Zakres","range":"(10 - 600) mg/m3"},{"name":"Zakres","range":"(0,15 - 3,89) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość metanolu\nZakres:\nZakres (10 - 600) mg/m3\nZakres (0,15 - 3,89) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2014, Zeszyt nr 81","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2014, Zeszyt nr 81"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość metanolu\nZakres:\nZakres (10 - 600) mg/m3\nZakres (0,15 - 3,89) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) Podstawy i Metody Oceny Środowiska Pracy 2014, Zeszyt nr 81 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc metanolu\nZakres:\nZakres (10 - 600) mg/m3\nZakres (0,15 - 3,89) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) Podstawy i Metody Oceny Srodowiska Pracy 2014, Zeszyt nr 81","categories":["environment"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Methanol concentration/content","parameters_en":[{"name":"Range","range":"(10 - 600) mg/m3"},{"name":"Range","range":"(0,15 - 3,89) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Methanol concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range Podstawy i Metody Oceny Środowiska Pracy 2014, Zeszyt nr 81","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(10 - 600) mg/m3"},{"name":"范围","range":"(0,15 - 3,89) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 甲醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 Podstawy i Metody Oceny Środowiska Pracy 2014, Zeszyt nr 81","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"甲醇的浓度/含量"},{"_id":"6a7d7be00636ba417e41c021","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość 1-metoksypropan-2-olu","parameters":[{"name":"Zakres","range":"(13 - 720) mg/m3"},{"name":"Zakres","range":"(0,22 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość 1-metoksypropan-2-olu\nZakres:\nZakres (13 - 720) mg/m3\nZakres (0,22 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04354:2005","norm_bases":["PN-Z-04354:2005"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość 1-metoksypropan-2-olu\nZakres:\nZakres (13 - 720) mg/m3\nZakres (0,22 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04354:2005 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc 1-metoksypropan-2-olu\nZakres:\nZakres (13 - 720) mg/m3\nZakres (0,22 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04354:2005","categories":["environment"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"1-methoxypropan-2-ol concentration/content","parameters_en":[{"name":"Range","range":"(13 - 720) mg/m3"},{"name":"Range","range":"(0,22 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes 1-methoxypropan-2-ol concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04354:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(13 - 720) mg/m3"},{"name":"范围","range":"(0,22 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 1-甲氧基-2-丙醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04354:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"1-甲氧基-2-丙醇的浓度/含量"},{"_id":"6a7d7be00636ba417e41c022","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość nafty","parameters":[{"name":"Zakres","range":"(7,8 - 600) mg/m3"},{"name":"Zakres","range":"(0,10 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość nafty\nZakres:\nZakres (7,8 - 600) mg/m3\nZakres (0,10 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-92/Z-04227/02","norm_bases":["PN-92/Z-04227/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość nafty\nZakres:\nZakres (7,8 - 600) mg/m3\nZakres (0,10 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-92/Z-04227/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc nafty\nZakres:\nZakres (7,8 - 600) mg/m3\nZakres (0,10 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-92/Z-04227/02","categories":["environment"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Kerosene concentration/content","parameters_en":[{"name":"Range","range":"(7,8 - 600) mg/m3"},{"name":"Range","range":"(0,10 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Kerosene concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-92/Z-04227/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(7,8 - 600) mg/m3"},{"name":"范围","range":"(0,10 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 煤油的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-92/Z-04227/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"煤油的浓度/含量"},{"_id":"6a7d7be00636ba417e41c023","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość heksanu -","parameters":[{"name":"Zakres","range":"(6,3 - 536) mg/m3"},{"name":"Zakres","range":"(0,065 - 3,4) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość heksanu -\nZakres:\nZakres (6,3 - 536) mg/m3\nZakres (0,065 - 3,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04136-03:2003","norm_bases":["PN-Z-04136-03:2003"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość heksanu -\nZakres:\nZakres (6,3 - 536) mg/m3\nZakres (0,065 - 3,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04136-03:2003 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc heksanu -\nZakres:\nZakres (6,3 - 536) mg/m3\nZakres (0,065 - 3,4) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04136-03:2003","categories":["environment"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Hexane concentration/content -","parameters_en":[{"name":"Range","range":"(6,3 - 536) mg/m3"},{"name":"Range","range":"(0,065 - 3,4) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Hexane concentration/content - Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04136-03:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(6,3 - 536) mg/m3"},{"name":"范围","range":"(0,065 - 3,4) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04136-03:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品"},{"_id":"6a7d7be00636ba417e41c024","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość octanu 2-butoksyetylu","parameters":[{"name":"Zakres","range":"(9,0 - 600) mg/m3"},{"name":"Zakres","range":"(0,11 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu 2-butoksyetylu\nZakres:\nZakres (9,0 - 600) mg/m3\nZakres (0,11 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04304:2003","norm_bases":["PN-Z-04304:2003"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość octanu 2-butoksyetylu\nZakres:\nZakres (9,0 - 600) mg/m3\nZakres (0,11 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04304:2003 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc octanu 2-butoksyetylu\nZakres:\nZakres (9,0 - 600) mg/m3\nZakres (0,11 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04304:2003","categories":["environment"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"2-butoxyethyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(9,0 - 600) mg/m3"},{"name":"Range","range":"(0,11 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes 2-butoxyethyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04304:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(9,0 - 600) mg/m3"},{"name":"范围","range":"(0,11 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 乙二醇丁醚醋酸酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04304:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"乙二醇丁醚醋酸酯的浓度/含量"},{"_id":"6a7d7be00636ba417e41c025","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość octanu butylu","parameters":[{"name":"Zakres","range":"(16 - 1900) mg/m3"},{"name":"Zakres","range":"(0,31 - 8,6) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu butylu\nZakres:\nZakres (16 - 1900) mg/m3\nZakres (0,31 - 8,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-78/Z-04119/01","norm_bases":["PN-78/Z-04119/01"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość octanu butylu\nZakres:\nZakres (16 - 1900) mg/m3\nZakres (0,31 - 8,6) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-78/Z-04119/01 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc octanu butylu\nZakres:\nZakres (16 - 1900) mg/m3\nZakres (0,31 - 8,6) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-78/Z-04119/01","categories":["environment"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Butyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(16 - 1900) mg/m3"},{"name":"Range","range":"(0,31 - 8,6) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Butyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-78/Z-04119/01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(16 - 1900) mg/m3"},{"name":"范围","range":"(0,31 - 8,6) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-78/Z-04119/01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品"},{"_id":"6a7d7be00636ba417e41c026","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość octanu etylu","parameters":[{"name":"Zakres","range":"(17 - 1500) mg/m3"},{"name":"Zakres","range":"(4,65 - 410,3) ppm"},{"name":"Zakres","range":"(1,14 - 23) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu etylu\nZakres:\nZakres (17 - 1500) mg/m3\nZakres (4,65 - 410,3) ppm\nZakres (1,14 - 23) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-78/Z-04119/01","norm_bases":["PN-78/Z-04119/01"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość octanu etylu\nZakres:\nZakres (17 - 1500) mg/m3\nZakres (4,65 - 410,3) ppm\nZakres (1,14 - 23) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-78/Z-04119/01 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc octanu etylu\nZakres:\nZakres (17 - 1500) mg/m3\nZakres (4,65 - 410,3) ppm\nZakres (1,14 - 23) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-78/Z-04119/01","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Ethyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(17 - 1500) mg/m3"},{"name":"Range","range":"(4,65 - 410,3) ppm"},{"name":"Range","range":"(1,14 - 23) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Ethyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range Range PN-78/Z-04119/01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(17 - 1500) mg/m3"},{"name":"范围","range":"(4,65 - 410,3) ppm"},{"name":"范围","range":"(1,14 - 23) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 乙酸乙酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 范围 PN-78/Z-04119/01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"乙酸乙酯的浓度/含量"},{"_id":"6a7d7be00636ba417e41c027","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość octanu metylu","parameters":[{"name":"Zakres","range":"(23 - 1200) mg/m3"},{"name":"Zakres","range":"(0,35 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu metylu\nZakres:\nZakres (23 - 1200) mg/m3\nZakres (0,35 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-78/Z-04119/01","norm_bases":["PN-78/Z-04119/01"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość octanu metylu\nZakres:\nZakres (23 - 1200) mg/m3\nZakres (0,35 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-78/Z-04119/01 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc octanu metylu\nZakres:\nZakres (23 - 1200) mg/m3\nZakres (0,35 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-78/Z-04119/01","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Methyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(23 - 1200) mg/m3"},{"name":"Range","range":"(0,35 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Methyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-78/Z-04119/01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(23 - 1200) mg/m3"},{"name":"范围","range":"(0,35 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 乙酸甲酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-78/Z-04119/01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"乙酸甲酯的浓度/含量"},{"_id":"6a7d7be00636ba417e41c028","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość octanu propylu","parameters":[{"name":"Zakres","range":"(19 - 2000) mg/m3"},{"name":"Zakres","range":"(0,22 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu propylu\nZakres:\nZakres (19 - 2000) mg/m3\nZakres (0,22 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-78/Z-04119/01","norm_bases":["PN-78/Z-04119/01"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość octanu propylu\nZakres:\nZakres (19 - 2000) mg/m3\nZakres (0,22 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-78/Z-04119/01 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc octanu propylu\nZakres:\nZakres (19 - 2000) mg/m3\nZakres (0,22 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-78/Z-04119/01","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of propyl acetate","parameters_en":[{"name":"Range","range":"(19 - 2000) mg/m3"},{"name":"Range","range":"(0,22 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of propyl acetate Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-78/Z-04119/01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(19 - 2000) mg/m3"},{"name":"范围","range":"(0,22 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-78/Z-04119/01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品"},{"_id":"6a7d7be00636ba417e41c029","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość octanu 2-metoksy-1-metyloetylu","parameters":[{"name":"Zakres","range":"(20 - 520) mg/m3"},{"name":"Zakres","range":"(0,36 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu 2-metoksy-1-metyloetylu\nZakres:\nZakres (20 - 520) mg/m3\nZakres (0,36 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04119-10:2008","norm_bases":["PN-Z-04119-10:2008"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość octanu 2-metoksy-1-metyloetylu\nZakres:\nZakres (20 - 520) mg/m3\nZakres (0,36 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04119-10:2008 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc octanu 2-metoksy-1-metyloetylu\nZakres:\nZakres (20 - 520) mg/m3\nZakres (0,36 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04119-10:2008","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"2-methoxy-1-methylethyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(20 - 520) mg/m3"},{"name":"Range","range":"(0,36 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes 2-methoxy-1-methylethyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04119-10:2008","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(20 - 520) mg/m3"},{"name":"范围","range":"(0,36 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 丙二醇甲醚醋酸酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04119-10:2008","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"丙二醇甲醚醋酸酯的浓度/含量"},{"_id":"6a7d7be00636ba417e41c02a","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość octanu winylu","parameters":[{"name":"Zakres","range":"(1,0 - 60) mg/m3"},{"name":"Zakres","range":"(0,08 - 5,2) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość octanu winylu\nZakres:\nZakres (1,0 - 60) mg/m3\nZakres (0,08 - 5,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-87/Z-04178/02","norm_bases":["PN-87/Z-04178/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość octanu winylu\nZakres:\nZakres (1,0 - 60) mg/m3\nZakres (0,08 - 5,2) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-87/Z-04178/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc octanu winylu\nZakres:\nZakres (1,0 - 60) mg/m3\nZakres (0,08 - 5,2) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-87/Z-04178/02","categories":["environment"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Vinyl acetate concentration/content","parameters_en":[{"name":"Range","range":"(1,0 - 60) mg/m3"},{"name":"Range","range":"(0,08 - 5,2) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Vinyl acetate concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-87/Z-04178/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(1,0 - 60) mg/m3"},{"name":"范围","range":"(0,08 - 5,2) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 乙酸乙烯酯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-87/Z-04178/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"乙酸乙烯酯的浓度/含量"},{"_id":"6a7d7be00636ba417e41c02b","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość pentanu","parameters":[{"name":"Zakres","range":"(300 - 6000) mg/m3"},{"name":"Zakres","range":"(0,41 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość pentanu\nZakres:\nZakres (300 - 6000) mg/m3\nZakres (0,41 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04318:2005","norm_bases":["PN-Z-04318:2005"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość pentanu\nZakres:\nZakres (300 - 6000) mg/m3\nZakres (0,41 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04318:2005 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc pentanu\nZakres:\nZakres (300 - 6000) mg/m3\nZakres (0,41 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04318:2005","categories":["environment"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Pentane concentration/content","parameters_en":[{"name":"Range","range":"(300 - 6000) mg/m3"},{"name":"Range","range":"(0,41 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Pentane concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04318:2005","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(300 - 6000) mg/m3"},{"name":"范围","range":"(0,41 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 戊烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04318:2005","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"戊烷的浓度/含量"},{"_id":"6a7d7be00636ba417e41c02c","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość propan-1-olu","parameters":[{"name":"Zakres","range":"(20 - 600) mg/m3"},{"name":"Zakres","range":"(0,20 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość propan-1-olu\nZakres:\nZakres (20 - 600) mg/m3\nZakres (0,20 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04224-3:2003","norm_bases":["PN-Z-04224-3:2003"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość propan-1-olu\nZakres:\nZakres (20 - 600) mg/m3\nZakres (0,20 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04224-3:2003 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc propan-1-olu\nZakres:\nZakres (20 - 600) mg/m3\nZakres (0,20 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04224-3:2003","categories":["environment"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration/content of propan-1-ol","parameters_en":[{"name":"Range","range":"(20 - 600) mg/m3"},{"name":"Range","range":"(0,20 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Concentration/content of propan-1-ol Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04224-3:2003","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(20 - 600) mg/m3"},{"name":"范围","range":"(0,20 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04224-3:2003","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品"},{"_id":"6a7d7be00636ba417e41c02d","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość propan-2-olu","parameters":[{"name":"Zakres","range":"(49 - 1200) mg/m3"},{"name":"Zakres","range":"(1,14 - 22,7) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość propan-2-olu\nZakres:\nZakres (49 - 1200) mg/m3\nZakres (1,14 - 22,7) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-92/Z-04224/02","norm_bases":["PN-92/Z-04224/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość propan-2-olu\nZakres:\nZakres (49 - 1200) mg/m3\nZakres (1,14 - 22,7) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-92/Z-04224/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc propan-2-olu\nZakres:\nZakres (49 - 1200) mg/m3\nZakres (1,14 - 22,7) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-92/Z-04224/02","categories":["environment"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Propan-2-ol concentration/content","parameters_en":[{"name":"Range","range":"(49 - 1200) mg/m3"},{"name":"Range","range":"(1,14 - 22,7) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Propan-2-ol concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-92/Z-04224/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(49 - 1200) mg/m3"},{"name":"范围","range":"(1,14 - 22,7) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 异丙醇的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-92/Z-04224/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"异丙醇的浓度/含量"},{"_id":"6a7d7be00636ba417e41c02e","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość styrenu","parameters":[{"name":"Zakres","range":"(3,7 - 400) mg/m3"},{"name":"Zakres","range":"(0,068 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość styrenu\nZakres:\nZakres (3,7 - 400) mg/m3\nZakres (0,068 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-86/Z-04152/02","norm_bases":["PN-86/Z-04152/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość styrenu\nZakres:\nZakres (3,7 - 400) mg/m3\nZakres (0,068 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-86/Z-04152/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc styrenu\nZakres:\nZakres (3,7 - 400) mg/m3\nZakres (0,068 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-86/Z-04152/02","categories":["environment"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Styrene concentration/content","parameters_en":[{"name":"Range","range":"(3,7 - 400) mg/m3"},{"name":"Range","range":"(0,068 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Styrene concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-86/Z-04152/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(3,7 - 400) mg/m3"},{"name":"范围","range":"(0,068 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 苯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-86/Z-04152/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"苯乙烯的浓度/含量"},{"_id":"6a7d7be00636ba417e41c02f","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość sewofluranu","parameters":[{"name":"Zakres","range":"(0,29 - 110) mg/m3"},{"name":"Zakres","range":"(0,005 - 2,0) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość sewofluranu\nZakres:\nZakres (0,29 - 110) mg/m3\nZakres (0,005 - 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04429:2011","norm_bases":["PN-Z-04429:2011"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość sewofluranu\nZakres:\nZakres (0,29 - 110) mg/m3\nZakres (0,005 - 2,0) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04429:2011 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc sewofluranu\nZakres:\nZakres (0,29 - 110) mg/m3\nZakres (0,005 - 2,0) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04429:2011","categories":["environment"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Sevoflurane concentration/content","parameters_en":[{"name":"Range","range":"(0,29 - 110) mg/m3"},{"name":"Range","range":"(0,005 - 2,0) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Sevoflurane concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-Z-04429:2011","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(0,29 - 110) mg/m3"},{"name":"范围","range":"(0,005 - 2,0) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 七氟烷的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-Z-04429:2011","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"七氟烷的浓度/含量"},{"_id":"6a7d7be00636ba417e41c030","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość tetrachloroetenu","parameters":[{"name":"Zakres","range":"(4,5 - 428) mg/m3"},{"name":"Zakres","range":"(0,65 - 62,2) ppm"},{"name":"Zakres","range":"(0,12 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość tetrachloroetenu\nZakres:\nZakres (4,5 - 428) mg/m3\nZakres (0,65 - 62,2) ppm\nZakres (0,12 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-83/Z-04118/02","norm_bases":["PN-83/Z-04118/02"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość tetrachloroetenu\nZakres:\nZakres (4,5 - 428) mg/m3\nZakres (0,65 - 62,2) ppm\nZakres (0,12 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-83/Z-04118/02 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc tetrachloroetenu\nZakres:\nZakres (4,5 - 428) mg/m3\nZakres (0,65 - 62,2) ppm\nZakres (0,12 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-83/Z-04118/02","categories":["environment"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Tetrachloroethene concentration/content","parameters_en":[{"name":"Range","range":"(4,5 - 428) mg/m3"},{"name":"Range","range":"(0,65 - 62,2) ppm"},{"name":"Range","range":"(0,12 - 20) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Tetrachloroethene concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range Range PN-83/Z-04118/02","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(4,5 - 428) mg/m3"},{"name":"范围","range":"(0,65 - 62,2) ppm"},{"name":"范围","range":"(0,12 - 20) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 四氯乙烯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 范围 PN-83/Z-04118/02","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"四氯乙烯的浓度/含量"},{"_id":"6a7d7be00636ba417e41c031","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Stężenie/zawartość toluenu","parameters":[{"name":"Zakres","range":"(8,3 - 700) mg/m3"},{"name":"Zakres","range":"(0,15 - 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość toluenu\nZakres:\nZakres (8,3 - 700) mg/m3\nZakres (0,15 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-78/Z-04115/01","norm_bases":["PN-78/Z-04115/01"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z węglem aktywnym Stężenie/zawartość toluenu\nZakres:\nZakres (8,3 - 700) mg/m3\nZakres (0,15 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-78/Z-04115/01 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z weglem aktywnym Stezenie/zawartosc toluenu\nZakres:\nZakres (8,3 - 700) mg/m3\nZakres (0,15 - 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-78/Z-04115/01","categories":["environment"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Toluene concentration/content","parameters_en":[{"name":"Range","range":"(8,3 - 700) mg/m3"},{"name":"Range","range":"(0,15 - 5) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on activated carbon tubes Toluene concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range PN-78/Z-04115/01","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on activated carbon tubes","parameters_zh":[{"name":"范围","range":"(8,3 - 700) mg/m3"},{"name":"范围","range":"(0,15 - 5) mg w próbce"}],"search_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品 甲苯的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 PN-78/Z-04115/01","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","test_object_zh":"工作场所环境 — 空气 — 用活性炭管采集的空气样品","methodology_zh":"甲苯的浓度/含量"},{"_id":"6a7d7be00636ba417e41c032","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z żelem krzemionkowym","methodology":"Stężenie/zawartość kwasu octowego","parameters":[{"name":"Zakres","range":"(1,3 - 60) mg/m3"},{"name":"Zakres","range":"(0,52 - 24,1) ppm"},{"name":"Zakres","range":"(0,12 - 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie/zawartość kwasu octowego\nZakres:\nZakres (1,3 - 60) mg/m3\nZakres (0,52 - 24,1) ppm\nZakres (0,12 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PN-Z-04323:2004","norm_bases":["PN-Z-04323:2004"],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze - próbki powietrza pobrane na rurki z żelem krzemionkowym Stężenie/zawartość kwasu octowego\nZakres:\nZakres (1,3 - 60) mg/m3\nZakres (0,52 - 24,1) ppm\nZakres (0,12 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PN-Z-04323:2004 Srodowisko pracy - powietrze - probki powietrza pobrane na rurki z zelem krzemionkowym Stezenie/zawartosc kwasu octowego\nZakres:\nZakres (1,3 - 60) mg/m3\nZakres (0,52 - 24,1) ppm\nZakres (0,12 - 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PN-Z-04323:2004","categories":["environment"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Acetic acid concentration/content","parameters_en":[{"name":"Range","range":"(1,3 - 60) mg/m3"},{"name":"Range","range":"(0,52 - 24,1) ppm"},{"name":"Range","range":"(0,12 - 5) mg w próbce"}],"search_en":"Workplace environment - air - air samples collected on silica gel tubes Acetic acid concentration/content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range Range Range PN-Z-04323:2004","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air - air samples collected on silica gel tubes","parameters_zh":[{"name":"范围","range":"(1,3 - 60) mg/m3"},{"name":"范围","range":"(0,52 - 24,1) ppm"},{"name":"范围","range":"(0,12 - 5) mg w próbce"}],"search_zh":"乙酸的浓度/含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 范围 范围 PN-Z-04323:2004","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"乙酸的浓度/含量"},{"_id":"6a7d7be00636ba417e41c033","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - powietrze","methodology":"Stężenie substancji chemicznych -","parameters":[{"name":"aceton","range":"(48 - 3600) mg/m3"},{"name":"benzen","range":"(0,063 - 3,05) mg/m3"},{"name":"Zakres","range":"(0,019 - 0,94) ppm"},{"name":"benzyna ekstrakcyjna","range":"(36 - 3000) mg/m3"},{"name":"benzyna do lakierów","range":"(24 - 1800) mg/m3"},{"name":"2-bromo-2-chloro-1,1,1-trifluoroetan (halotan)","range":"(0,5 - 200) mg/m3"},{"name":"butan-1-ol (alkohol n-butylowy)","range":"(4,5 - 300) mg/m3"},{"name":"butan-2-on","range":"(44 - 900) mg/m3"},{"name":"2-butoksyetanol","range":"(8,3 - 400) mg/m3"},{"name":"cykloheksan","range":"(30 - 2000) mg/m3"},{"name":"cykloheksanon","range":"(4 - 160) mg/m3"},{"name":"dichlorometan","range":"(6,6 - 746) mg/m3"},{"name":"(1,87 - 211,7) ppm"},{"name":"etanol","range":"(114 - 3800) mg/m3"},{"name":"eter dietylowy","range":"(26 - 3000) mg/m3"},{"name":"etylobenzen","range":"(8,4 - 700) mg/m3"},{"name":"glikol etylenowy","range":"(1,3 - 100) mg/m3"},{"name":"izofluran","range":"(0,78 - 64) mg/m3"},{"name":"kwas octowy","range":"(1,3 - 60) mg/m3"},{"name":"(0,52 - 24,1) ppm"},{"name":"ksylen – mieszanina izomerów","range":"1,2-;"},{"name":"1,3-; 1,4","range":"(8,5 - 200) mg/m3"},{"name":"metanol","range":"(10 - 600) mg/m3"},{"name":"1-metoksypropan-2-ol","range":"(13 - 720) mg/m3"},{"name":"nafta","range":"(7,8 - 600) mg/m3"},{"name":"n-heksan","range":"(6,3 - 536) mg/m3"},{"name":"octan 2-butoksyetylu","range":"(9,0 - 600) mg/m3"},{"name":"octan butylu","range":"(16 - 1900) mg/m3"},{"name":"octan etylu","range":"(17 - 1500) mg/m3"},{"name":"(4,65 - 410,3) ppm"},{"name":"octan metylu","range":"(23 - 1200) mg/m3"},{"name":"octan propylu","range":"(19 - 2000) mg/m3"},{"name":"octan 2-metoksy-1-metyloetylu","range":"(20 - 520) mg/m3"},{"name":"octan winylu","range":"(1,0 - 60) mg/m3"},{"name":"pentan","range":"(300 - 6000) mg/m3"},{"name":"propan-1-ol","range":"(20 - 600) mg/m3"},{"name":"propan-2-ol","range":"(49 - 1200) mg/m3"},{"name":"styren","range":"(3,7 - 400) mg/m3"},{"name":"sewofluran","range":"(0,29 - 110) mg/m3"},{"name":"tetrachloroeten","range":"(4,5 - 428) mg/m3"},{"name":"(0,65 - 62,2) ppm"},{"name":"toluen","range":"(8,3 - 700) mg/m3"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Stężenie substancji chemicznych -\nZakres:\naceton (48 - 3600) mg/m3\nbenzen (0,063 - 3,05) mg/m3\nZakres (0,019 - 0,94) ppm\nbenzyna ekstrakcyjna (36 - 3000) mg/m3\nbenzyna do lakierów (24 - 1800) mg/m3\n2-bromo-2-chloro-1,1,1-trifluoroetan (halotan) (0,5 - 200) mg/m3\nbutan-1-ol (alkohol n-butylowy) (4,5 - 300) mg/m3\nbutan-2-on (44 - 900) mg/m3\n2-butoksyetanol (8,3 - 400) mg/m3\ncykloheksan (30 - 2000) mg/m3\ncykloheksanon (4 - 160) mg/m3\ndichlorometan (6,6 - 746) mg/m3\n(1,87 - 211,7) ppm\netanol (114 - 3800) mg/m3\neter dietylowy (26 - 3000) mg/m3\netylobenzen (8,4 - 700) mg/m3\nglikol etylenowy (1,3 - 100) mg/m3\nizofluran (0,78 - 64) mg/m3\nkwas octowy (1,3 - 60) mg/m3\n(0,52 - 24,1) ppm\nksylen – mieszanina izomerów 1,2-;\n1,3-; 1,4 (8,5 - 200) mg/m3\nmetanol (10 - 600) mg/m3\n1-metoksypropan-2-ol (13 - 720) mg/m3\nnafta (7,8 - 600) mg/m3\nn-heksan (6,3 - 536) mg/m3\noctan 2-butoksyetylu (9,0 - 600) mg/m3\noctan butylu (16 - 1900) mg/m3\noctan etylu (17 - 1500) mg/m3\n(4,65 - 410,3) ppm\noctan metylu (23 - 1200) mg/m3\noctan propylu (19 - 2000) mg/m3\noctan 2-metoksy-1-metyloetylu (20 - 520) mg/m3\noctan winylu (1,0 - 60) mg/m3\npentan (300 - 6000) mg/m3\npropan-1-ol (20 - 600) mg/m3\npropan-2-ol (49 - 1200) mg/m3\nstyren (3,7 - 400) mg/m3\nsewofluran (0,29 - 110) mg/m3\ntetrachloroeten (4,5 - 428) mg/m3\n(0,65 - 62,2) ppm\ntoluen (8,3 - 700) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-14 wydanie 3 z dnia 10.06.2016 r.","norm_bases":["PB-14 wydanie 3 z dnia 10.06.2016 r."],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - powietrze Stężenie substancji chemicznych -\nZakres:\naceton (48 - 3600) mg/m3\nbenzen (0,063 - 3,05) mg/m3\nZakres (0,019 - 0,94) ppm\nbenzyna ekstrakcyjna (36 - 3000) mg/m3\nbenzyna do lakierów (24 - 1800) mg/m3\n2-bromo-2-chloro-1,1,1-trifluoroetan (halotan) (0,5 - 200) mg/m3\nbutan-1-ol (alkohol n-butylowy) (4,5 - 300) mg/m3\nbutan-2-on (44 - 900) mg/m3\n2-butoksyetanol (8,3 - 400) mg/m3\ncykloheksan (30 - 2000) mg/m3\ncykloheksanon (4 - 160) mg/m3\ndichlorometan (6,6 - 746) mg/m3\n(1,87 - 211,7) ppm\netanol (114 - 3800) mg/m3\neter dietylowy (26 - 3000) mg/m3\netylobenzen (8,4 - 700) mg/m3\nglikol etylenowy (1,3 - 100) mg/m3\nizofluran (0,78 - 64) mg/m3\nkwas octowy (1,3 - 60) mg/m3\n(0,52 - 24,1) ppm\nksylen – mieszanina izomerów 1,2-;\n1,3-; 1,4 (8,5 - 200) mg/m3\nmetanol (10 - 600) mg/m3\n1-metoksypropan-2-ol (13 - 720) mg/m3\nnafta (7,8 - 600) mg/m3\nn-heksan (6,3 - 536) mg/m3\noctan 2-butoksyetylu (9,0 - 600) mg/m3\noctan butylu (16 - 1900) mg/m3\noctan etylu (17 - 1500) mg/m3\n(4,65 - 410,3) ppm\noctan metylu (23 - 1200) mg/m3\noctan propylu (19 - 2000) mg/m3\noctan 2-metoksy-1-metyloetylu (20 - 520) mg/m3\noctan winylu (1,0 - 60) mg/m3\npentan (300 - 6000) mg/m3\npropan-1-ol (20 - 600) mg/m3\npropan-2-ol (49 - 1200) mg/m3\nstyren (3,7 - 400) mg/m3\nsewofluran (0,29 - 110) mg/m3\ntetrachloroeten (4,5 - 428) mg/m3\n(0,65 - 62,2) ppm\ntoluen (8,3 - 700) mg/m3\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-14 wydanie 3 z dnia 10.06.2016 r. Srodowisko pracy - powietrze Stezenie substancji chemicznych -\nZakres:\naceton (48 - 3600) mg/m3\nbenzen (0,063 - 3,05) mg/m3\nZakres (0,019 - 0,94) ppm\nbenzyna ekstrakcyjna (36 - 3000) mg/m3\nbenzyna do lakierow (24 - 1800) mg/m3\n2-bromo-2-chloro-1,1,1-trifluoroetan (halotan) (0,5 - 200) mg/m3\nbutan-1-ol (alkohol n-butylowy) (4,5 - 300) mg/m3\nbutan-2-on (44 - 900) mg/m3\n2-butoksyetanol (8,3 - 400) mg/m3\ncykloheksan (30 - 2000) mg/m3\ncykloheksanon (4 - 160) mg/m3\ndichlorometan (6,6 - 746) mg/m3\n(1,87 - 211,7) ppm\netanol (114 - 3800) mg/m3\neter dietylowy (26 - 3000) mg/m3\netylobenzen (8,4 - 700) mg/m3\nglikol etylenowy (1,3 - 100) mg/m3\nizofluran (0,78 - 64) mg/m3\nkwas octowy (1,3 - 60) mg/m3\n(0,52 - 24,1) ppm\nksylen – mieszanina izomerow 1,2-;\n1,3-; 1,4 (8,5 - 200) mg/m3\nmetanol (10 - 600) mg/m3\n1-metoksypropan-2-ol (13 - 720) mg/m3\nnafta (7,8 - 600) mg/m3\nn-heksan (6,3 - 536) mg/m3\noctan 2-butoksyetylu (9,0 - 600) mg/m3\noctan butylu (16 - 1900) mg/m3\noctan etylu (17 - 1500) mg/m3\n(4,65 - 410,3) ppm\noctan metylu (23 - 1200) mg/m3\noctan propylu (19 - 2000) mg/m3\noctan 2-metoksy-1-metyloetylu (20 - 520) mg/m3\noctan winylu (1,0 - 60) mg/m3\npentan (300 - 6000) mg/m3\npropan-1-ol (20 - 600) mg/m3\npropan-2-ol (49 - 1200) mg/m3\nstyren (3,7 - 400) mg/m3\nsewofluran (0,29 - 110) mg/m3\ntetrachloroeten (4,5 - 428) mg/m3\n(0,65 - 62,2) ppm\ntoluen (8,3 - 700) mg/m3\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-14 wydanie 3 z dnia 10.06.2016 r.","categories":["environment","petro","automotive"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Concentration of chemical substances -","parameters_en":[{"name":"acetone","range":"(48 - 3600) mg/m3"},{"name":"benzene","range":"(0,063 - 3,05) mg/m3"},{"name":"Range","range":"(0,019 - 0,94) ppm"},{"name":"extraction naphtha","range":"(36 - 3000) mg/m3"},{"name":"white spirit","range":"(24 - 1800) mg/m3"},{"name":"2-bromo-2-chloro-1,1,1-trifluoroethane (halothane)","range":"(0,5 - 200) mg/m3"},{"name":"butan-1-ol (n-butyl alcohol)","range":"(4,5 - 300) mg/m3"},{"name":"butan-2-one","range":"(44 - 900) mg/m3"},{"name":"2-butoxyethanol","range":"(8,3 - 400) mg/m3"},{"name":"cyclohexane","range":"(30 - 2000) mg/m3"},{"name":"cyclohexanone","range":"(4 - 160) mg/m3"},{"name":"dichloromethane","range":"(6,6 - 746) mg/m3"},{"name":"(1,87 - 211,7) ppm"},{"name":"ethanol","range":"(114 - 3800) mg/m3"},{"name":"diethyl ether","range":"(26 - 3000) mg/m3"},{"name":"ethylbenzene","range":"(8,4 - 700) mg/m3"},{"name":"ethylene glycol","range":"(1,3 - 100) mg/m3"},{"name":"isoflurane","range":"(0,78 - 64) mg/m3"},{"name":"acetic acid","range":"(1,3 - 60) mg/m3"},{"name":"(0,52 - 24,1) ppm"},{"name":"xylene – mixture of isomers","range":"1,2-;"},{"name":"1,3-; 1,4","range":"(8,5 - 200) mg/m3"},{"name":"methanol","range":"(10 - 600) mg/m3"},{"name":"1-methoxypropan-2-ol","range":"(13 - 720) mg/m3"},{"name":"kerosene","range":"(7,8 - 600) mg/m3"},{"name":"n-hexane","range":"(6,3 - 536) mg/m3"},{"name":"2-butoxyethyl acetate","range":"(9,0 - 600) mg/m3"},{"name":"butyl acetate","range":"(16 - 1900) mg/m3"},{"name":"ethyl acetate","range":"(17 - 1500) mg/m3"},{"name":"(4,65 - 410,3) ppm"},{"name":"methyl acetate","range":"(23 - 1200) mg/m3"},{"name":"propyl acetate","range":"(19 - 2000) mg/m3"},{"name":"2-methoxy-1-methylethyl acetate","range":"(20 - 520) mg/m3"},{"name":"vinyl acetate","range":"(1,0 - 60) mg/m3"},{"name":"pentane","range":"(300 - 6000) mg/m3"},{"name":"propan-1-ol","range":"(20 - 600) mg/m3"},{"name":"propan-2-ol","range":"(49 - 1200) mg/m3"},{"name":"styrene","range":"(3,7 - 400) mg/m3"},{"name":"sevoflurane","range":"(0,29 - 110) mg/m3"},{"name":"tetrachloroethene","range":"(4,5 - 428) mg/m3"},{"name":"(0,65 - 62,2) ppm"},{"name":"toluene","range":"(8,3 - 700) mg/m3"}],"search_en":"Workplace environment - air Concentration of chemical substances - Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. acetone benzene Range extraction naphtha white spirit 2-bromo-2-chloro-1,1,1-trifluoroethane (halothane) butan-1-ol (n-butyl alcohol) butan-2-one 2-butoxyethanol cyclohexane cyclohexanone dichloromethane (1,87 - 211,7) ppm ethanol diethyl ether ethylbenzene ethylene glycol isoflurane acetic acid (0,52 - 24,1) ppm xylene – mixture of isomers 1,3-; 1,4 methanol 1-methoxypropan-2-ol kerosene n-hexane 2-butoxyethyl acetate butyl acetate ethyl acetate (4,65 - 410,3) ppm methyl acetate propyl acetate 2-methoxy-1-methylethyl acetate vinyl acetate pentane propan-1-ol propan-2-ol styrene sevoflurane tetrachloroethene (0,65 - 62,2) ppm toluene PB-14 wydanie 3 z dnia 10.06.2016 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air","parameters_zh":[{"name":"丙酮","range":"(48 - 3600) mg/m3"},{"name":"苯","range":"(0,063 - 3,05) mg/m3"},{"name":"范围","range":"(0,019 - 0,94) ppm"},{"name":"抽提汽油","range":"(36 - 3000) mg/m3"},{"name":"油漆用溶剂汽油","range":"(24 - 1800) mg/m3"},{"name":"2-bromo-2-chloro-1,1,1-trifluoroetan (halotan)","range":"(0,5 - 200) mg/m3"},{"name":"butan-1-ol (alkohol n-butylowy)","range":"(4,5 - 300) mg/m3"},{"name":"丁酮","range":"(44 - 900) mg/m3"},{"name":"2-丁氧基乙醇","range":"(8,3 - 400) mg/m3"},{"name":"环己烷","range":"(30 - 2000) mg/m3"},{"name":"环己酮","range":"(4 - 160) mg/m3"},{"name":"二氯甲烷","range":"(6,6 - 746) mg/m3"},{"name":"(1,87 - 211,7) ppm"},{"name":"乙醇","range":"(114 - 3800) mg/m3"},{"name":"乙醚","range":"(26 - 3000) mg/m3"},{"name":"乙苯","range":"(8,4 - 700) mg/m3"},{"name":"glikol etylenowy","range":"(1,3 - 100) mg/m3"},{"name":"izofluran","range":"(0,78 - 64) mg/m3"},{"name":"乙酸","range":"(1,3 - 60) mg/m3"},{"name":"(0,52 - 24,1) ppm"},{"name":"二甲苯 － 异构体混合物","range":"1,2-;"},{"name":"1,3-; 1,4","range":"(8,5 - 200) mg/m3"},{"name":"甲醇","range":"(10 - 600) mg/m3"},{"name":"1-甲氧基-2-丙醇","range":"(13 - 720) mg/m3"},{"name":"煤油","range":"(7,8 - 600) mg/m3"},{"name":"正己烷","range":"(6,3 - 536) mg/m3"},{"name":"乙二醇丁醚醋酸酯","range":"(9,0 - 600) mg/m3"},{"name":"乙酸丁酯","range":"(16 - 1900) mg/m3"},{"name":"乙酸乙酯","range":"(17 - 1500) mg/m3"},{"name":"(4,65 - 410,3) ppm"},{"name":"乙酸甲酯","range":"(23 - 1200) mg/m3"},{"name":"乙酸丙酯","range":"(19 - 2000) mg/m3"},{"name":"丙二醇甲醚醋酸酯","range":"(20 - 520) mg/m3"},{"name":"乙酸乙烯酯","range":"(1,0 - 60) mg/m3"},{"name":"戊烷","range":"(300 - 6000) mg/m3"},{"name":"正丙醇","range":"(20 - 600) mg/m3"},{"name":"异丙醇","range":"(49 - 1200) mg/m3"},{"name":"苯乙烯","range":"(3,7 - 400) mg/m3"},{"name":"sewofluran","range":"(0,29 - 110) mg/m3"},{"name":"四氯乙烯","range":"(4,5 - 428) mg/m3"},{"name":"(0,65 - 62,2) ppm"},{"name":"甲苯","range":"(8,3 - 700) mg/m3"}],"search_zh":"工作场所环境 — 空气 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 丙酮 苯 范围 抽提汽油 油漆用溶剂汽油 丁酮 2-丁氧基乙醇 环己烷 环己酮 二氯甲烷 乙醇 乙醚 乙苯 乙酸 二甲苯 － 异构体混合物 甲醇 1-甲氧基-2-丙醇 煤油 正己烷 乙二醇丁醚醋酸酯 乙酸丁酯 乙酸乙酯 乙酸甲酯 乙酸丙酯 丙二醇甲醚醋酸酯 乙酸乙烯酯 戊烷 正丙醇 异丙醇 苯乙烯 四氯乙烯 甲苯 PB-14 wydanie 3 z dnia 10.06.2016 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","test_object_zh":"工作场所环境 — 空气","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41c034","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Zawartość substancji chemicznych","parameters":[{"name":"aceton (0,15 - 3,95) mg w próbce benzen (0,0006 - 0,029) mg w próbce benzyna ekstrakcyjna"},{"name":"Zakres","range":"(0,2 - 19,7) mg w próbce"},{"name":"benzyna do lakierów (0,36 - 20) mg w próbce 2-bromo-2-chloro-1,1,1-trifluoroetan (halotan) - (0,009 - 2,0) mg w próbce butan-1-ol (alkohol n-butylowy) (0,078 - 1,95) mg w próbce butan-2-on (0,49 - 9,8) mg w próbce 2-butoksyetanol (0,15 - 20) mg w próbce cykloheksan (0,38 - 20) mg w próbce cykloheksanon (0,045 - 2,25) mg w próbce dichlorometan (0,065 - 4,7) mg w próbce etanol (0,38 - 11,8) mg w próbce eter dietylowy (0,35 - 20) mg w próbce etylobenzen (0,27 - 9,10) mg w próbce glikol etylenowy (0,11 - 8,0) mg w próbce izofluran (0,056 - 1,2) mg w próbce"},{"name":"Ksylen – mieszanina izomerów","range":"1,2-;"},{"name":"1,3-; 1,4-(0,09 - 17) mg w próbce metanol (0,15 - 3,89) mg w próbce 1-metoksypropan-2-ol (0,22 - 20) mg w próbce nafta (0,10 - 20) mg w próbce n-heksan (0,065 - 3,4) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość substancji chemicznych\nZakres:\naceton (0,15 - 3,95) mg w próbce benzen (0,0006 - 0,029) mg w próbce benzyna ekstrakcyjna\nZakres (0,2 - 19,7) mg w próbce\nbenzyna do lakierów (0,36 - 20) mg w próbce 2-bromo-2-chloro-1,1,1-trifluoroetan (halotan) - (0,009 - 2,0) mg w próbce butan-1-ol (alkohol n-butylowy) (0,078 - 1,95) mg w próbce butan-2-on (0,49 - 9,8) mg w próbce 2-butoksyetanol (0,15 - 20) mg w próbce cykloheksan (0,38 - 20) mg w próbce cykloheksanon (0,045 - 2,25) mg w próbce dichlorometan (0,065 - 4,7) mg w próbce etanol (0,38 - 11,8) mg w próbce eter dietylowy (0,35 - 20) mg w próbce etylobenzen (0,27 - 9,10) mg w próbce glikol etylenowy (0,11 - 8,0) mg w próbce izofluran (0,056 - 1,2) mg w próbce\nKsylen – mieszanina izomerów 1,2-;\n1,3-; 1,4-(0,09 - 17) mg w próbce metanol (0,15 - 3,89) mg w próbce 1-metoksypropan-2-ol (0,22 - 20) mg w próbce nafta (0,10 - 20) mg w próbce n-heksan (0,065 - 3,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-14 wydanie 3 z dnia 10.06.2016 r.","norm_bases":["PB-14 wydanie 3 z dnia 10.06.2016 r."],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z węglem aktywnym Zawartość substancji chemicznych\nZakres:\naceton (0,15 - 3,95) mg w próbce benzen (0,0006 - 0,029) mg w próbce benzyna ekstrakcyjna\nZakres (0,2 - 19,7) mg w próbce\nbenzyna do lakierów (0,36 - 20) mg w próbce 2-bromo-2-chloro-1,1,1-trifluoroetan (halotan) - (0,009 - 2,0) mg w próbce butan-1-ol (alkohol n-butylowy) (0,078 - 1,95) mg w próbce butan-2-on (0,49 - 9,8) mg w próbce 2-butoksyetanol (0,15 - 20) mg w próbce cykloheksan (0,38 - 20) mg w próbce cykloheksanon (0,045 - 2,25) mg w próbce dichlorometan (0,065 - 4,7) mg w próbce etanol (0,38 - 11,8) mg w próbce eter dietylowy (0,35 - 20) mg w próbce etylobenzen (0,27 - 9,10) mg w próbce glikol etylenowy (0,11 - 8,0) mg w próbce izofluran (0,056 - 1,2) mg w próbce\nKsylen – mieszanina izomerów 1,2-;\n1,3-; 1,4-(0,09 - 17) mg w próbce metanol (0,15 - 3,89) mg w próbce 1-metoksypropan-2-ol (0,22 - 20) mg w próbce nafta (0,10 - 20) mg w próbce n-heksan (0,065 - 3,4) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-14 wydanie 3 z dnia 10.06.2016 r. Srodowisko pracy - probki powietrza pobrane na rurki z weglem aktywnym Zawartosc substancji chemicznych\nZakres:\naceton (0,15 - 3,95) mg w probce benzen (0,0006 - 0,029) mg w probce benzyna ekstrakcyjna\nZakres (0,2 - 19,7) mg w probce\nbenzyna do lakierow (0,36 - 20) mg w probce 2-bromo-2-chloro-1,1,1-trifluoroetan (halotan) - (0,009 - 2,0) mg w probce butan-1-ol (alkohol n-butylowy) (0,078 - 1,95) mg w probce butan-2-on (0,49 - 9,8) mg w probce 2-butoksyetanol (0,15 - 20) mg w probce cykloheksan (0,38 - 20) mg w probce cykloheksanon (0,045 - 2,25) mg w probce dichlorometan (0,065 - 4,7) mg w probce etanol (0,38 - 11,8) mg w probce eter dietylowy (0,35 - 20) mg w probce etylobenzen (0,27 - 9,10) mg w probce glikol etylenowy (0,11 - 8,0) mg w probce izofluran (0,056 - 1,2) mg w probce\nKsylen – mieszanina izomerow 1,2-;\n1,3-; 1,4-(0,09 - 17) mg w probce metanol (0,15 - 3,89) mg w probce 1-metoksypropan-2-ol (0,22 - 20) mg w probce nafta (0,10 - 20) mg w probce n-heksan (0,065 - 3,4) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-14 wydanie 3 z dnia 10.06.2016 r.","categories":["environment","petro","automotive"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Content of chemical substances","parameters_en":[{"name":"acetone (0,15 - 3,95) mg in the sample benzene (0,0006 - 0,029) mg in the sample extraction naphtha"},{"name":"Range","range":"(0,2 - 19,7) mg w próbce"},{"name":"white spirit (0,36 - 20) mg in the sample 2-bromo-2-chloro-1,1,1-trifluoroethane (halothane) - (0,009 - 2,0) mg in the sample butan-1-ol (n-butyl alcohol) (0,078 - 1,95) mg in the sample butan-2-one (0,49 - 9,8) mg in the sample 2-butoxyethanol (0,15 - 20) mg in the sample cyclohexane (0,38 - 20) mg in the sample cyclohexanone (0,045 - 2,25) mg in the sample dichloromethane (0,065 - 4,7) mg in the sample ethanol (0,38 - 11,8) mg in the sample diethyl ether (0,35 - 20) mg in the sample ethylbenzene (0,27 - 9,10) mg in the sample ethylene glycol (0,11 - 8,0) mg in the sample isoflurane (0,056 - 1,2) mg in the sample"},{"name":"Xylene – mixture of isomers","range":"1,2-;"},{"name":"1,3-; 1,4-(0,09 - 17) mg in the sample methanol (0,15 - 3,89) mg in the sample 1-methoxypropan-2-ol (0,22 - 20) mg in the sample kerosene (0,10 - 20) mg in the sample n-hexane (0,065 - 3,4) mg in the sample"}],"search_en":"Workplace environment - air samples collected on activated carbon tubes Content of chemical substances Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. acetone (0,15 - 3,95) mg in the sample benzene (0,0006 - 0,029) mg in the sample extraction naphtha Range white spirit (0,36 - 20) mg in the sample 2-bromo-2-chloro-1,1,1-trifluoroethane (halothane) - (0,009 - 2,0) mg in the sample butan-1-ol (n-butyl alcohol) (0,078 - 1,95) mg in the sample butan-2-one (0,49 - 9,8) mg in the sample 2-butoxyethanol (0,15 - 20) mg in the sample cyclohexane (0,38 - 20) mg in the sample cyclohexanone (0,045 - 2,25) mg in the sample dichloromethane (0,065 - 4,7) mg in the sample ethanol (0,38 - 11,8) mg in the sample diethyl ether (0,35 - 20) mg in the sample ethylbenzene (0,27 - 9,10) mg in the sample ethylene glycol (0,11 - 8,0) mg in the sample isoflurane (0,056 - 1,2) mg in the sample Xylene – mixture of isomers 1,3-; 1,4-(0,09 - 17) mg in the sample methanol (0,15 - 3,89) mg in the sample 1-methoxypropan-2-ol (0,22 - 20) mg in the sample kerosene (0,10 - 20) mg in the sample n-hexane (0,065 - 3,4) mg in the sample PB-14 wydanie 3 z dnia 10.06.2016 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air samples collected on activated carbon tubes","parameters_zh":[{"name":"aceton (0,15 - 3,95) mg w próbce benzen (0,0006 - 0,029) mg w próbce benzyna ekstrakcyjna"},{"name":"范围","range":"(0,2 - 19,7) mg w próbce"},{"name":"benzyna do lakierów (0,36 - 20) mg w próbce 2-bromo-2-chloro-1,1,1-trifluoroetan (halotan) - (0,009 - 2,0) mg w próbce butan-1-ol (alkohol n-butylowy) (0,078 - 1,95) mg w próbce butan-2-on (0,49 - 9,8) mg w próbce 2-butoksyetanol (0,15 - 20) mg w próbce cykloheksan (0,38 - 20) mg w próbce cykloheksanon (0,045 - 2,25) mg w próbce dichlorometan (0,065 - 4,7) mg w próbce etanol (0,38 - 11,8) mg w próbce eter dietylowy (0,35 - 20) mg w próbce etylobenzen (0,27 - 9,10) mg w próbce glikol etylenowy (0,11 - 8,0) mg w próbce izofluran (0,056 - 1,2) mg w próbce"},{"name":"Ksylen – mieszanina izomerów","range":"1,2-;"},{"name":"1,3-; 1,4-(0,09 - 17) mg w próbce metanol (0,15 - 3,89) mg w próbce 1-metoksypropan-2-ol (0,22 - 20) mg w próbce nafta (0,10 - 20) mg w próbce n-heksan (0,065 - 3,4) mg w próbce"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 PB-14 wydanie 3 z dnia 10.06.2016 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41c035","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z węglem aktywnym","methodology":"Zawartość substancji chemicznych","parameters":[{"name":"octan 2-butoksyetylu"},{"name":"Zakres","range":"(0,11 - 20) mg w próbce"},{"name":"octan butylu (0,31 - 8,6) mg w próbce octan etylu (1,14 - 23) mg w próbce octan metylu (0,35 - 20) mg w próbce octan propylu (0,22 - 20) mg w próbce octan 2-metoksy-1-metyloetylu – (0,36 - 20) mg w próbce octan winylu (0,08 - 5,2) mg w próbce pentan (0,41 - 20) mg w próbce propan-1-ol (0,20 - 20) mg w próbce propan-2-ol (1,14 - 22,7) mg w próbce sewofluran (0,005 - 2,0) mg w próbce styren (0,068 - 20) mg w próbce toluen (0,15 - 5) mg w próbce tetrachloroeten (0,12 - 20) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość substancji chemicznych\nZakres:\noctan 2-butoksyetylu\nZakres (0,11 - 20) mg w próbce\noctan butylu (0,31 - 8,6) mg w próbce octan etylu (1,14 - 23) mg w próbce octan metylu (0,35 - 20) mg w próbce octan propylu (0,22 - 20) mg w próbce octan 2-metoksy-1-metyloetylu – (0,36 - 20) mg w próbce octan winylu (0,08 - 5,2) mg w próbce pentan (0,41 - 20) mg w próbce propan-1-ol (0,20 - 20) mg w próbce propan-2-ol (1,14 - 22,7) mg w próbce sewofluran (0,005 - 2,0) mg w próbce styren (0,068 - 20) mg w próbce toluen (0,15 - 5) mg w próbce tetrachloroeten (0,12 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-14 wydanie 3 z dnia 10.06.2016 r.","norm_bases":["PB-14 wydanie 3 z dnia 10.06.2016 r."],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z węglem aktywnym Zawartość substancji chemicznych\nZakres:\noctan 2-butoksyetylu\nZakres (0,11 - 20) mg w próbce\noctan butylu (0,31 - 8,6) mg w próbce octan etylu (1,14 - 23) mg w próbce octan metylu (0,35 - 20) mg w próbce octan propylu (0,22 - 20) mg w próbce octan 2-metoksy-1-metyloetylu – (0,36 - 20) mg w próbce octan winylu (0,08 - 5,2) mg w próbce pentan (0,41 - 20) mg w próbce propan-1-ol (0,20 - 20) mg w próbce propan-2-ol (1,14 - 22,7) mg w próbce sewofluran (0,005 - 2,0) mg w próbce styren (0,068 - 20) mg w próbce toluen (0,15 - 5) mg w próbce tetrachloroeten (0,12 - 20) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-14 wydanie 3 z dnia 10.06.2016 r. Srodowisko pracy - probki powietrza pobrane na rurki z weglem aktywnym Zawartosc substancji chemicznych\nZakres:\noctan 2-butoksyetylu\nZakres (0,11 - 20) mg w probce\noctan butylu (0,31 - 8,6) mg w probce octan etylu (1,14 - 23) mg w probce octan metylu (0,35 - 20) mg w probce octan propylu (0,22 - 20) mg w probce octan 2-metoksy-1-metyloetylu – (0,36 - 20) mg w probce octan winylu (0,08 - 5,2) mg w probce pentan (0,41 - 20) mg w probce propan-1-ol (0,20 - 20) mg w probce propan-2-ol (1,14 - 22,7) mg w probce sewofluran (0,005 - 2,0) mg w probce styren (0,068 - 20) mg w probce toluen (0,15 - 5) mg w probce tetrachloroeten (0,12 - 20) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-14 wydanie 3 z dnia 10.06.2016 r.","categories":["environment"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Content of chemical substances","parameters_en":[{"name":"2-butoxyethyl acetate"},{"name":"Range","range":"(0,11 - 20) mg w próbce"},{"name":"butyl acetate (0,31 - 8,6) mg in sample ethyl acetate (1,14 - 23) mg in sample methyl acetate (0,35 - 20) mg in sample propyl acetate (0,22 - 20) mg in sample 2-methoxy-1-methylethyl acetate – (0,36 - 20) mg in sample vinyl acetate (0,08 - 5,2) mg in sample pentane (0,41 - 20) mg in sample propan-1-ol (0,20 - 20) mg in sample propan-2-ol (1,14 - 22,7) mg in sample sevoflurane (0,005 - 2,0) mg in sample styrene (0,068 - 20) mg in sample toluene (0,15 - 5) mg in sample tetrachloroethene (0,12 - 20) mg in sample"}],"search_en":"Workplace environment - air samples collected on activated carbon tubes Content of chemical substances Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 2-butoxyethyl acetate Range butyl acetate (0,31 - 8,6) mg in sample ethyl acetate (1,14 - 23) mg in sample methyl acetate (0,35 - 20) mg in sample propyl acetate (0,22 - 20) mg in sample 2-methoxy-1-methylethyl acetate – (0,36 - 20) mg in sample vinyl acetate (0,08 - 5,2) mg in sample pentane (0,41 - 20) mg in sample propan-1-ol (0,20 - 20) mg in sample propan-2-ol (1,14 - 22,7) mg in sample sevoflurane (0,005 - 2,0) mg in sample styrene (0,068 - 20) mg in sample toluene (0,15 - 5) mg in sample tetrachloroethene (0,12 - 20) mg in sample PB-14 wydanie 3 z dnia 10.06.2016 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air samples collected on activated carbon tubes","parameters_zh":[{"name":"乙二醇丁醚醋酸酯"},{"name":"范围","range":"(0,11 - 20) mg w próbce"},{"name":"octan butylu (0,31 - 8,6) mg w próbce octan etylu (1,14 - 23) mg w próbce octan metylu (0,35 - 20) mg w próbce octan propylu (0,22 - 20) mg w próbce octan 2-metoksy-1-metyloetylu – (0,36 - 20) mg w próbce octan winylu (0,08 - 5,2) mg w próbce pentan (0,41 - 20) mg w próbce propan-1-ol (0,20 - 20) mg w próbce propan-2-ol (1,14 - 22,7) mg w próbce sewofluran (0,005 - 2,0) mg w próbce styren (0,068 - 20) mg w próbce toluen (0,15 - 5) mg w próbce tetrachloroeten (0,12 - 20) mg w próbce"}],"search_zh":"气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 乙二醇丁醚醋酸酯 范围 PB-14 wydanie 3 z dnia 10.06.2016 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o."},{"_id":"6a7d7be00636ba417e41c036","lab_id":"69ad52a3de79e566650fb350","country":"PL","accr_number":"AB 647","accr_body":"PCA","test_object":"Środowisko pracy - próbki powietrza pobrane na rurki z żelem krzemionkowym","methodology":"Zawartość kwasu octowego","parameters":[{"name":"Zakres","range":"(0,12 - 5) mg w próbce"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość kwasu octowego\nZakres (0,12 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID)","reference":"PB-14 wydanie 3 z dnia 10.06.2016 r.","norm_bases":["PB-14 wydanie 3 z dnia 10.06.2016 r."],"lab_section":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Środowisko pracy - próbki powietrza pobrane na rurki z żelem krzemionkowym Zawartość kwasu octowego\nZakres (0,12 - 5) mg w próbce\nMetoda chromatografii gazowej z detekcją płomieniowo-jonizacyjną (GC-FID) PB-14 wydanie 3 z dnia 10.06.2016 r. Srodowisko pracy - probki powietrza pobrane na rurki z zelem krzemionkowym Zawartosc kwasu octowego\nZakres (0,12 - 5) mg w probce\nMetoda chromatografii gazowej z detekcja plomieniowo-jonizacyjna (GC-FID) PB-14 wydanie 3 z dnia 10.06.2016 r.","categories":["environment"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_en":"Acetic acid content","parameters_en":[{"name":"Range","range":"(0,12 - 5) mg w próbce"}],"search_en":"Workplace environment - air samples collected on silica gel tubes Acetic acid content Gas chromatography with flame ionization detection (GC-FID) „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. Range PB-14 wydanie 3 z dnia 10.06.2016 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Workplace environment - air samples collected on silica gel tubes","parameters_zh":[{"name":"范围","range":"(0,12 - 5) mg w próbce"}],"search_zh":"乙酸含量 气相色谱-氢火焰离子化检测法（GC-FID） „ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o. 范围 PB-14 wydanie 3 z dnia 10.06.2016 r.","technique_zh":"气相色谱-氢火焰离子化检测法（GC-FID）","lab_section_zh":"„ECOLABAD” Laboratorium Fizyko-Chemiczne Badania i Analizy Środowiska Sp. z o.o.","methodology_zh":"乙酸含量"}],"has_pdf":true}