🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL

PCA AB 623 • Złotoryja, Poland • 27 methods

Water & wastewaterMicrobiology

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 623 (Złotoryja, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water intended for human consumption, Water intended for human consumption, Swimming pool water, Swimming pool water, Domestic hot water. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Titrimetric method.

At a glance

  • Accreditation number: PCA AB 623
  • Methods in scope: 27
  • Types of test objects: 6
  • Techniques used: 13
  • City: Złotoryja, Poland
Accreditation number
AB 623
Accreditation body
PCA
Address
W ZŁOTORYI, ul. Stanisława Staszica 22, 59-500 Złotoryja
City
Złotoryja, Poland

What this laboratory tests (6)

Analytical techniques used (13)

Laboratory sections (3)

Laboratory locations

Accreditation scope — test methods (27)

No. Test object Methodology / Parameters Technique Reference document
Laboratory Division; Physicochemical Testing Laboratory
1 Water intended for human consumption, Swimming pool water pH
Range 4,0 - 10,0
Potentiometric method PN-EN ISO 10523:2012
2 Water intended for human consumption, Swimming pool water Turbidity
Range (0,10 - 100) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
3 Water intended for human consumption, Swimming pool water Nitrate concentration
Range (1,0 - 80) mg/l
Spectrophotometric method PN-82/C-04576.08
4 Water intended for human consumption, Swimming pool water Total iron concentration
Range (0,030 - 0,500) mg/l
Spectrophotometric method PN-ISO 6332:2001+Ap1:2016-06
5 Water intended for human consumption, Swimming pool water Permanganate index
Range (0,5 - 10,0) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
6 Water intended for human consumption Nitrite concentration
Range (0,004 - 0,80) mg/l
Spectrophotometric method PN-EN 26777:1999
7 Water intended for human consumption Electrical conductivity
Range (80 - 2770) μS/cm
Conductometric method PN-EN 27888:1999
8 Water intended for human consumption Colour
Range (5 - 70) mg/l Pt
Visual method PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D
9 Water intended for human consumption Ammonium ion concentration
Range (0,050 - 1,0) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
10 Water intended for human consumption Manganese concentration
Range (0,030 - 4,0) mg/l
Spectrophotometric method PN-92/C-04590/03
11 Water intended for human consumption Chloride concentration
Range (5,0 - 284) mg/l
Titrimetric method PN-ISO 9297:1994
12 Water intended for human consumption Total calcium and magnesium content (Total hardness)
Range (5 - 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
13 Water intended for human consumption Sulfate concentration
Range (10 - 250) mg/l
Gravimetric method PN-ISO 9280:2002
14 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
Laboratory Division; Water Microbiological Testing Laboratory
15 Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
16 Water intended for human consumption Total viable count at 22°C Plate method (pour plate) PN-EN ISO 6222:2004
17 Water intended for human consumption Coliform bacteria and Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014 -12 +A1:2017-04
18 Swimming pool water Total viable count at 36°C Plate method (pour plate) PN-EN ISO 6222:2004
19 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PN-Z-11001-3:2000
20 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014 -12 +A1:2017-04
21 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
22 Water intended for human consumption, Swimming pool water Sampling for microbiological testing PN EN ISO 19458:2007
23 Domestic hot water Legionella spp. count, Matrix A procedure 7 medium C (GVPC) procedure 5 medium A (BCYE) Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
24 Domestic hot water Legionella pneumophila sp. count, Matrix A procedure 7 medium C (GVPC) procedure 5 medium A (BCYE) Membrane filtration method with serological confirmation PN-EN ISO 11731:2017-08 +Ap1:2019-12 Metodyka OXOID – Legionella Latex Test Symbol: DR 800M
Laboratory Division; Microbiology Laboratory
25 Faeces Presence and identification of rods of the genera Salmonella and Shigella Culture method with biochemical and serological confirmation PB- 02/Z wydanie 07 z dnia 20.10.2023 r. | na podstawie metodyk Państwowego Zakładu Higieny
26 Faeces Presence and identification of rods of the genus Yersinia Culture method with biochemical confirmation PB-10/Z wydanie 04 z dnia 20.12.2023 r.
27 Biological indicator for sterilization process efficacy control – ampoule test Presence of the indicator microorganism Geobacillus stearothermophilus Culture method PB-04/Z Wydanie 05 z dnia 30.09.2025 r.

Reference standards (26)

PB- 02/Z wydanie 07 z dnia 20.10.2023 r.
PB-04/Z Wydanie 05 z dnia 30.09.2025 r.
PB-10/Z wydanie 04 z dnia 20.12.2023 r.
PN EN ISO 19458:2007
PN-82/C-04576.08
PN-92/C-04590/03
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 11731:2017-08 +Ap1:2019-12 Metodyka OXOID – Legionella Latex Test Symbol: DR 800M
PN-EN ISO 16266:2009
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014 -12 +A1:2017-04
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
PN-Z-11001-3:2000
na podstawie metodyk Państwowego Zakładu Higieny