{"lab":{"_id":"69ad52a3de79e566650fb332","accr_number":"AB 623","country":"PL","accr_body":"PCA","address":"W ZŁOTORYI, ul. Stanisława Staszica 22, 59-500 Złotoryja","categories":["water","microbiology"],"city":"Złotoryja","imported_at":"2026-03-08T10:42:43.265Z","methods_count":27,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":2,"pdf_files":["AB_623.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w złotoryi, ul. stanisława staszica 22, 59-500 złotoryja water other pharma electronics microbiology automotive food","status":"active","updated_at":"2026-03-08T14:51:31.562Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-13T08:09:35.194Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20623,podmiot.html","fields_of_testing":[{"codes":"C/28, C/29/P","pl":"Badania chemiczne wody, wody do spożycia przez ludzi i pobieranie próbek wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water and sampling of drinking water"},{"codes":"K/3","pl":"Badania mikrobiologiczne materiałów biologicznych przeznaczonych do badań","en":"Microbiological tests of biological items and materials for testing"},{"codes":"K/28/P, K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi/","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"N/28, N/29/P","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi i pobieranie próbek wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water and sampling of drinking water"}],"issue":{"no":"20","date":"06.07.2026"},"parse_date":"2026-08-13T08:09:35.194Z","parse_source":"agent-claude-code","map_coord":[51.12398,15.920142],"map_geo":"nominatim-street","lab_locations":[{"name":"Oddział Laboratoryjny","address":"ul. Staszica 22,59-500 Złotoryja","city":"Złotoryja","postal":"59-500"},{"name":"Laboratorium Badań Fizyko-Chemicznych","address":"ul. Staszica 22,59-500 Złotoryja","city":"Złotoryja","postal":"59-500"},{"name":"Laboratorium Badań Mikrobiologicznych Wody","address":"ul. Staszica 22,59-500 Złotoryja","city":"Złotoryja","postal":"59-500"},{"name":"Laboratorium Mikrobiologiczne","address":"ul. Staszica 22,59-500 Złotoryja","city":"Złotoryja","postal":"59-500"},{"name":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","address":null,"city":null,"postal":null},{"name":"Oddział Laboratoryjny; Laboratorium Badań Mikrobiologicznych Wody","address":null,"city":null,"postal":null},{"name":"Oddział Laboratoryjny; Laboratorium Mikrobiologiczne","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/13/c2ddfd69e067a54ddc4f8ece2a2a12aa/AB%20623.pdf","has_en":true,"category_counts":{"water":24,"microbiology":7,"other":1},"category_scores":{"water":18,"microbiology":1.53,"other":0.03},"has_zh":true,"lab_locations_zh":[{"name":"Oddział Laboratoryjny","address":"ul. Staszica 22,59-500 Złotoryja","city":"Złotoryja","postal":"59-500"},{"name":"Laboratorium Badań Fizyko-Chemicznych","address":"ul. Staszica 22,59-500 Złotoryja","city":"Złotoryja","postal":"59-500"},{"name":"Laboratorium Badań Mikrobiologicznych Wody","address":"ul. Staszica 22,59-500 Złotoryja","city":"Złotoryja","postal":"59-500"},{"name":"微生物实验室","address":"ul. Staszica 22,59-500 Złotoryja","city":"Złotoryja","postal":"59-500"},{"name":"实验室分部；理化检验实验室","address":null,"city":null,"postal":null},{"name":"实验室分部；水微生物检验实验室","address":null,"city":null,"postal":null},{"name":"Oddział Laboratoryjny; Laboratorium Mikrobiologiczne","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a7d7bbf0636ba417e41bee5","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 - 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi, Woda na plywalniach pH\nZakres 4,0 - 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 - 10,0"}],"search_en":"Water intended for human consumption, Swimming pool water pH Potentiometric method Laboratory Division; Physicochemical Testing Laboratory Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption, Swimming pool water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 - 10,0"}],"search_zh":"生活饮用水、游泳池水 pH 值 电位法 实验室分部；理化检验实验室 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水、游泳池水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41bee6","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 - 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi, Woda na plywalniach Metnosc\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 - 100) NTU"}],"search_en":"Water intended for human consumption, Swimming pool water Turbidity Nephelometric method Laboratory Division; Physicochemical Testing Laboratory Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption, Swimming pool water","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 - 100) NTU"}],"search_zh":"生活饮用水、游泳池水 浊度 浊度法（散射法） 实验室分部；理化检验实验室 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水、游泳池水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41bee7","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1,0 - 80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (1,0 - 80) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Stężenie azotanów\nZakres (1,0 - 80) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda do spozycia przez ludzi, Woda na plywalniach Stezenie azotanow\nZakres (1,0 - 80) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(1,0 - 80) mg/l"}],"search_en":"Water intended for human consumption, Swimming pool water Nitrate concentration Spectrophotometric method Laboratory Division; Physicochemical Testing Laboratory Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Swimming pool water","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,0 - 80) mg/l"}],"search_zh":"生活饮用水、游泳池水 硝酸盐浓度 分光光度法 实验室分部；理化检验实验室 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"生活饮用水、游泳池水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41bee8","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,030 - 0,500) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,030 - 0,500) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Stężenie żelaza ogólnego\nZakres (0,030 - 0,500) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi, Woda na plywalniach Stezenie zelaza ogolnego\nZakres (0,030 - 0,500) mg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,030 - 0,500) mg/l"}],"search_en":"Water intended for human consumption, Swimming pool water Total iron concentration Spectrophotometric method Laboratory Division; Physicochemical Testing Laboratory Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Swimming pool water","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,030 - 0,500) mg/l"}],"search_zh":"生活饮用水、游泳池水 总铁浓度 分光光度法 实验室分部；理化检验实验室 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水、游泳池水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41bee9","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,5 - 10,0) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,5 - 10,0) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Indeks nadmanganianowy\nZakres (0,5 - 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi, Woda na plywalniach Indeks nadmanganianowy\nZakres (0,5 - 10,0) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,5 - 10,0) mg/l O2"}],"search_en":"Water intended for human consumption, Swimming pool water Permanganate index Titrimetric method Laboratory Division; Physicochemical Testing Laboratory Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption, Swimming pool water","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,5 - 10,0) mg/l O2"}],"search_zh":"生活饮用水、游泳池水 高锰酸盐指数 滴定法 实验室分部；理化检验实验室 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水、游泳池水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41beea","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,004 - 0,80) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,004 - 0,80) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,004 - 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,004 - 0,80) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,004 - 0,80) mg/l"}],"search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Laboratory Division; Physicochemical Testing Laboratory Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,004 - 0,80) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 实验室分部；理化检验实验室 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41beeb","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(80 - 2770) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (80 - 2770) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (80 - 2770) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (80 - 2770) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(80 - 2770) μS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Laboratory Division; Physicochemical Testing Laboratory Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(80 - 2770) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 实验室分部；理化检验实验室 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41beec","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 - 70) mg/l Pt"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (5 - 70) mg/l Pt\nMetoda wizualna","reference":"PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","norm_bases":["PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 - 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D Woda do spozycia przez ludzi Barwa\nZakres (5 - 70) mg/l Pt\nMetoda wizualna PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 - 70) mg/l Pt"}],"search_en":"Water intended for human consumption Colour Visual method Laboratory Division; Physicochemical Testing Laboratory Range PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","technique_en":"Visual method","test_object_en":"Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 - 70) mg/l Pt"}],"search_zh":"生活饮用水 色度 目视法 实验室分部；理化检验实验室 范围 PN-EN ISO 7887:2012+Ap1:2015-06 Metoda D","technique_zh":"目视法","test_object_zh":"生活饮用水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41beed","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,050 - 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,050 - 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,050 - 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,050 - 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,050 - 1,0) mg/l"}],"search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Laboratory Division; Physicochemical Testing Laboratory Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,050 - 1,0) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 实验室分部；理化检验实验室 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41beee","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,030 - 4,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,030 - 4,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/03","norm_bases":["PN-92/C-04590/03"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,030 - 4,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03 Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,030 - 4,0) mg/l\nMetoda spektrofotometryczna PN-92/C-04590/03","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,030 - 4,0) mg/l"}],"search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Laboratory Division; Physicochemical Testing Laboratory Range PN-92/C-04590/03","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,030 - 4,0) mg/l"}],"search_zh":"生活饮用水 锰浓度 分光光度法 实验室分部；理化检验实验室 范围 PN-92/C-04590/03","technique_zh":"分光光度法","test_object_zh":"生活饮用水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41beef","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 - 284) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 - 284) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 - 284) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 - 284) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 - 284) mg/l"}],"search_en":"Water intended for human consumption Chloride concentration Titrimetric method Laboratory Division; Physicochemical Testing Laboratory Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 - 284) mg/l"}],"search_zh":"生活饮用水 氯化物浓度 滴定法 实验室分部；理化检验实验室 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41bef0","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (Twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 - 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (Twardość ogólna)\nZakres (5 - 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (Twardość ogólna)\nZakres (5 - 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (Twardosc ogolna)\nZakres (5 - 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Total calcium and magnesium content (Total hardness)","parameters_en":[{"name":"Range","range":"(5 - 500) mg/l CaCO3"}],"search_en":"Water intended for human consumption Total calcium and magnesium content (Total hardness) Titrimetric method Laboratory Division; Physicochemical Testing Laboratory Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(5 - 500) mg/l CaCO3"}],"search_zh":"生活饮用水 钙与镁总含量（总硬度） 滴定法 实验室分部；理化检验实验室 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水","lab_section_zh":"实验室分部；理化检验实验室","methodology_zh":"钙与镁总含量（总硬度）"},{"_id":"6a7d7bbf0636ba417e41bef1","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(10 - 250) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (10 - 250) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie siarczanów\nZakres (10 - 250) mg/l\nMetoda wagowa PN-ISO 9280:2002 Woda do spozycia przez ludzi Stezenie siarczanow\nZakres (10 - 250) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(10 - 250) mg/l"}],"search_en":"Water intended for human consumption Sulfate concentration Gravimetric method Laboratory Division; Physicochemical Testing Laboratory Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(10 - 250) mg/l"}],"search_zh":"生活饮用水 硫酸盐浓度 重量法 实验室分部；理化检验实验室 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"生活饮用水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41bef2","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Fizyko-Chemicznych","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Physicochemical Testing Laboratory","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing Laboratory Division; Physicochemical Testing Laboratory PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 实验室分部；理化检验实验室 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水","lab_section_zh":"实验室分部；理化检验实验室"},{"_id":"6a7d7bbf0636ba417e41bef3","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Mikrobiologicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Water Microbiological Testing Laboratory","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method Laboratory Division; Water Microbiological Testing Laboratory PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 实验室分部；水微生物检验实验室 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"实验室分部；水微生物检验实验室"},{"_id":"6a7d7bbf0636ba417e41bef4","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Mikrobiologicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temp. 22°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Water Microbiological Testing Laboratory","methodology_en":"Total viable count at 22°C","search_en":"Water intended for human consumption Total viable count at 22°C Plate method (pour plate) Laboratory Division; Water Microbiological Testing Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","methodology_zh":"22°C 微生物总数","search_zh":"生活饮用水 22°C 微生物总数 平板法（倾注培养） 实验室分部；水微生物检验实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水","lab_section_zh":"实验室分部；水微生物检验实验室"},{"_id":"6a7d7bbf0636ba417e41bef5","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli i Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli i Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014 -12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014 -12 +A1:2017-04"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Mikrobiologicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli i Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014 -12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli i Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014 -12 +A1:2017-04","categories":["microbiology","water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Water Microbiological Testing Laboratory","methodology_en":"Coliform bacteria and Escherichia coli count","search_en":"Water intended for human consumption Coliform bacteria and Escherichia coli count Membrane filtration method Laboratory Division; Water Microbiological Testing Laboratory PN-EN ISO 9308-1:2014 -12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 大肠菌群数与大肠埃希氏菌数 膜过滤法 实验室分部；水微生物检验实验室 PN-EN ISO 9308-1:2014 -12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","lab_section_zh":"实验室分部；水微生物检验实验室","methodology_zh":"大肠菌群数与大肠埃希氏菌数"},{"_id":"6a7d7bbf0636ba417e41bef6","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Ogólna liczba mikroorganizmów w temp. 36°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Mikrobiologicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda na plywalniach Ogolna liczba mikroorganizmow w temp. 36°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Water Microbiological Testing Laboratory","methodology_en":"Total viable count at 36°C","search_en":"Swimming pool water Total viable count at 36°C Plate method (pour plate) Laboratory Division; Water Microbiological Testing Laboratory PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Swimming pool water","search_zh":"游泳池水 36°C 微生物总数 平板法（倾注培养） 实验室分部；水微生物检验实验室 PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"游泳池水","methodology_zh":"36°C 微生物总数","lab_section_zh":"实验室分部；水微生物检验实验室"},{"_id":"6a7d7bbf0636ba417e41bef7","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba gronkowców koagulazododatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"PN-Z-11001-3:2000","norm_bases":["PN-Z-11001-3:2000"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Mikrobiologicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000 Woda na plywalniach Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej PN-Z-11001-3:2000","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Water Microbiological Testing Laboratory","methodology_en":"Coagulase-positive staphylococci count","search_en":"Swimming pool water Coagulase-positive staphylococci count Membrane filtration method Laboratory Division; Water Microbiological Testing Laboratory PN-Z-11001-3:2000","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","search_zh":"游泳池水 凝固酶阳性葡萄球菌计数 膜过滤法 实验室分部；水微生物检验实验室 PN-Z-11001-3:2000","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌计数","lab_section_zh":"实验室分部；水微生物检验实验室"},{"_id":"6a7d7bbf0636ba417e41bef8","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014 -12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014 -12 +A1:2017-04"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Mikrobiologicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014 -12 +A1:2017-04 Woda na plywalniach Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014 -12 +A1:2017-04","categories":["water","microbiology"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Water Microbiological Testing Laboratory","methodology_en":"Escherichia coli count","search_en":"Swimming pool water Escherichia coli count Membrane filtration method Laboratory Division; Water Microbiological Testing Laboratory PN-EN ISO 9308-1:2014 -12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"游泳池水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 实验室分部；水微生物检验实验室 PN-EN ISO 9308-1:2014 -12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"游泳池水","lab_section_zh":"实验室分部；水微生物检验实验室"},{"_id":"6a7d7bbf0636ba417e41bef9","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Mikrobiologicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda na plywalniach Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Water Microbiological Testing Laboratory","methodology_en":"Pseudomonas aeruginosa count","search_en":"Swimming pool water Pseudomonas aeruginosa count Membrane filtration method Laboratory Division; Water Microbiological Testing Laboratory PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","methodology_zh":"铜绿假单胞菌计数","search_zh":"游泳池水 铜绿假单胞菌计数 膜过滤法 实验室分部；水微生物检验实验室 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"游泳池水","lab_section_zh":"实验室分部；水微生物检验实验室"},{"_id":"6a7d7bbf0636ba417e41befa","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN EN ISO 19458:2007","norm_bases":["PN EN ISO 19458:2007"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Mikrobiologicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Pobieranie próbek do badań mikrobiologicznych PN EN ISO 19458:2007 Woda do spozycia przez ludzi, Woda na plywalniach Pobieranie probek do badan mikrobiologicznych PN EN ISO 19458:2007","categories":["water","microbiology"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Water Microbiological Testing Laboratory","methodology_en":"Sampling for microbiological testing","search_en":"Water intended for human consumption, Swimming pool water Sampling for microbiological testing Laboratory Division; Water Microbiological Testing Laboratory PN EN ISO 19458:2007","test_object_en":"Water intended for human consumption, Swimming pool water","methodology_zh":"微生物检测用样品采集","search_zh":"生活饮用水、游泳池水 微生物检测用样品采集 实验室分部；水微生物检验实验室 PN EN ISO 19458:2007","test_object_zh":"生活饮用水、游泳池水","lab_section_zh":"实验室分部；水微生物检验实验室"},{"_id":"6a7d7bbf0636ba417e41befb","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda ciepła użytkowa","methodology":"Liczba bakterii Legionella spp., Matryca A procedura 7 podłoże C (GVPC) procedura 5 podłoże A (BCYE)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Legionella spp., Matryca A procedura 7 podłoże C (GVPC) procedura 5 podłoże A (BCYE)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Mikrobiologicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda ciepła użytkowa Liczba bakterii Legionella spp., Matryca A procedura 7 podłoże C (GVPC) procedura 5 podłoże A (BCYE)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda ciepla uzytkowa Liczba bakterii Legionella spp., Matryca A procedura 7 podloze C (GVPC) procedura 5 podloze A (BCYE)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Water Microbiological Testing Laboratory","methodology_en":"Legionella spp. count, Matrix A procedure 7 medium C (GVPC) procedure 5 medium A (BCYE)","search_en":"Domestic hot water Legionella spp. count, Matrix A procedure 7 medium C (GVPC) procedure 5 medium A (BCYE) Membrane filtration method Laboratory Division; Water Microbiological Testing Laboratory PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Domestic hot water","search_zh":"生活热水 膜过滤法 实验室分部；水微生物检验实验室 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","lab_section_zh":"实验室分部；水微生物检验实验室","test_object_zh":"生活热水"},{"_id":"6a7d7bbf0636ba417e41befc","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Woda ciepła użytkowa","methodology":"Liczba Legionella pneumophila sp., Matryca A procedura 7 podłoże C (GVPC) procedura 5 podłoże A (BCYE)","parameters":[],"technique":"Metoda filtracji membranowej z potwierdzeniem serologicznym","techniques":["Metoda filtracji membranowej z potwierdzeniem serologicznym"],"computed":[],"activity":"Liczba Legionella pneumophila sp., Matryca A procedura 7 podłoże C (GVPC) procedura 5 podłoże A (BCYE)\nMetoda filtracji membranowej z potwierdzeniem serologicznym","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12 Metodyka OXOID – Legionella Latex Test Symbol: DR 800M","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12 Metodyka OXOID – Legionella Latex Test Symbol: DR 800M"],"lab_section":"Oddział Laboratoryjny; Laboratorium Badań Mikrobiologicznych Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda ciepła użytkowa Liczba Legionella pneumophila sp., Matryca A procedura 7 podłoże C (GVPC) procedura 5 podłoże A (BCYE)\nMetoda filtracji membranowej z potwierdzeniem serologicznym PN-EN ISO 11731:2017-08 +Ap1:2019-12 Metodyka OXOID – Legionella Latex Test Symbol: DR 800M Woda ciepla uzytkowa Liczba Legionella pneumophila sp., Matryca A procedura 7 podloze C (GVPC) procedura 5 podloze A (BCYE)\nMetoda filtracji membranowej z potwierdzeniem serologicznym PN-EN ISO 11731:2017-08 +Ap1:2019-12 Metodyka OXOID – Legionella Latex Test Symbol: DR 800M","categories":["microbiology","water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Water Microbiological Testing Laboratory","methodology_en":"Legionella pneumophila sp. count, Matrix A procedure 7 medium C (GVPC) procedure 5 medium A (BCYE)","search_en":"Domestic hot water Legionella pneumophila sp. count, Matrix A procedure 7 medium C (GVPC) procedure 5 medium A (BCYE) Membrane filtration method with serological confirmation Laboratory Division; Water Microbiological Testing Laboratory PN-EN ISO 11731:2017-08 +Ap1:2019-12 Metodyka OXOID – Legionella Latex Test Symbol: DR 800M","technique_en":"Membrane filtration method with serological confirmation","test_object_en":"Domestic hot water","lab_section_zh":"实验室分部；水微生物检验实验室","search_zh":"生活热水 实验室分部；水微生物检验实验室 PN-EN ISO 11731:2017-08 +Ap1:2019-12 Metodyka OXOID – Legionella Latex Test Symbol: DR 800M","test_object_zh":"生活热水"},{"_id":"6a7d7bbf0636ba417e41befd","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Kał","methodology":"Obecność i identyfikacja pałeczek z rodzaju Salmonella i Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność i identyfikacja pałeczek z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB- 02/Z wydanie 07 z dnia 20.10.2023 r. | na podstawie metodyk Państwowego Zakładu Higieny","norm_bases":["PB- 02/Z wydanie 07 z dnia 20.10.2023 r.","na podstawie metodyk Państwowego Zakładu Higieny"],"lab_section":"Oddział Laboratoryjny; Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał Obecność i identyfikacja pałeczek z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB- 02/Z wydanie 07 z dnia 20.10.2023 r. | na podstawie metodyk Państwowego Zakładu Higieny Kal Obecnosc i identyfikacja paleczek z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB- 02/Z wydanie 07 z dnia 20.10.2023 r. | na podstawie metodyk Panstwowego Zakladu Higieny","categories":["microbiology"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Microbiology Laboratory","methodology_en":"Presence and identification of rods of the genera Salmonella and Shigella","search_en":"Faeces Presence and identification of rods of the genera Salmonella and Shigella Culture method with biochemical and serological confirmation Laboratory Division; Microbiology Laboratory PB- 02/Z wydanie 07 z dnia 20.10.2023 r. | na podstawie metodyk Państwowego Zakładu Higieny","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces","search_zh":"粪便 沙门氏菌属与志贺氏菌属的检出与鉴定 培养法结合生化与血清学确认 PB- 02/Z wydanie 07 z dnia 20.10.2023 r. | na podstawie metodyk Państwowego Zakładu Higieny","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"粪便","methodology_zh":"沙门氏菌属与志贺氏菌属的检出与鉴定"},{"_id":"6a7d7bbf0636ba417e41befe","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Kał","methodology":"Obecność i identyfikacja pałeczek z rodzaju Yersinia","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność i identyfikacja pałeczek z rodzaju Yersinia\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PB-10/Z wydanie 04 z dnia 20.12.2023 r.","norm_bases":["PB-10/Z wydanie 04 z dnia 20.12.2023 r."],"lab_section":"Oddział Laboratoryjny; Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał Obecność i identyfikacja pałeczek z rodzaju Yersinia\nMetoda hodowlana z potwierdzeniem biochemicznym PB-10/Z wydanie 04 z dnia 20.12.2023 r. Kal Obecnosc i identyfikacja paleczek z rodzaju Yersinia\nMetoda hodowlana z potwierdzeniem biochemicznym PB-10/Z wydanie 04 z dnia 20.12.2023 r.","categories":["other"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Microbiology Laboratory","methodology_en":"Presence and identification of rods of the genus Yersinia","search_en":"Faeces Presence and identification of rods of the genus Yersinia Culture method with biochemical confirmation Laboratory Division; Microbiology Laboratory PB-10/Z wydanie 04 z dnia 20.12.2023 r.","technique_en":"Culture method with biochemical confirmation","test_object_en":"Faeces","search_zh":"粪便 耶尔森氏菌属细菌的检出与鉴定 培养法结合生化确认 PB-10/Z wydanie 04 z dnia 20.12.2023 r.","technique_zh":"培养法结合生化确认","test_object_zh":"粪便","methodology_zh":"耶尔森氏菌属细菌的检出与鉴定"},{"_id":"6a7d7bbf0636ba417e41beff","lab_id":"69ad52a3de79e566650fb332","country":"PL","accr_number":"AB 623","accr_body":"PCA","test_object":"Biologiczny wskaźnik kontroli sku- teczności procesu sterylizacji – test ampułkowy","methodology":"Obecność drobnoustroju wskaźnikowego Geobacillus stearothermophilus","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność drobnoustroju wskaźnikowego Geobacillus stearothermophilus\nMetoda hodowlana","reference":"PB-04/Z Wydanie 05 z dnia 30.09.2025 r.","norm_bases":["PB-04/Z Wydanie 05 z dnia 30.09.2025 r."],"lab_section":"Oddział Laboratoryjny; Laboratorium Mikrobiologiczne","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biologiczny wskaźnik kontroli sku- teczności procesu sterylizacji – test ampułkowy Obecność drobnoustroju wskaźnikowego Geobacillus stearothermophilus\nMetoda hodowlana PB-04/Z Wydanie 05 z dnia 30.09.2025 r. Biologiczny wskaznik kontroli sku- tecznosci procesu sterylizacji – test ampulkowy Obecnosc drobnoustroju wskaznikowego Geobacillus stearothermophilus\nMetoda hodowlana PB-04/Z Wydanie 05 z dnia 30.09.2025 r.","categories":["microbiology"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","lab_section_en":"Laboratory Division; Microbiology Laboratory","methodology_en":"Presence of the indicator microorganism Geobacillus stearothermophilus","search_en":"Biological indicator for sterilization process efficacy control – ampoule test Presence of the indicator microorganism Geobacillus stearothermophilus Culture method Laboratory Division; Microbiology Laboratory PB-04/Z Wydanie 05 z dnia 30.09.2025 r.","technique_en":"Culture method","test_object_en":"Biological indicator for sterilization process efficacy control – ampoule test","search_zh":"指示微生物嗜热脂肪土芽孢杆菌的检出 培养法 PB-04/Z Wydanie 05 z dnia 30.09.2025 r.","technique_zh":"培养法","methodology_zh":"指示微生物嗜热脂肪土芽孢杆菌的检出"}],"has_pdf":true}