🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL

PCA AB 617 • Sandomierz, Poland • 39 methods

Water & wastewaterMicrobiologyFood & beverages

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 617 (Sandomierz, Poland). Its accreditation scope covers 39 test methods in the following areas: Water & wastewater, Microbiology, Food & beverages. Test objects include: Water intended for human consumption, Food E, Water, Water intended for human consumption, Swimming pool water. Most frequently used techniques: Spectrophotometric method, Plate method (pour plate), Membrane filtration method.

At a glance

  • Accreditation number: PCA AB 617
  • Methods in scope: 39
  • Types of test objects: 10
  • Techniques used: 13
  • City: Sandomierz, Poland
Accreditation number
AB 617
Accreditation body
PCA
Address
W SANDOMIERZU, ul. Frankowskiego 8, 27-600 Sandomierz
City
Sandomierz, Poland

What this laboratory tests (10)

Analytical techniques used (13)

Laboratory sections (3)

Laboratory locations

Accreditation scope — test methods (39)

No. Test object Methodology / Parameters Technique Reference document
Oddział Laboratoryjny; Pracownia Badania Żywności
1 Food E Enterobacteriaceae count at 37°C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Plate method (pour plate) PN-ISO 21528-2
2 Food E Listeria monocytogenes count
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Plate method (spread plate) PN-EN ISO 11290-2
3 Food E Coliform bacteria count at 37°C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Plate method (pour plate) PN-ISO 4832
4 Food E Total viable count at 30°C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Plate method (pour plate) PN-EN ISO 4833
5 Food E Liczba bakterii β-glukuronidazododatnich Escherichia coli w 44°C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Plate method (pour plate) PN-ISO 16649-2
6 Food E Count of coagulase-positive staphylococci (Staphylococcus aureus and other species) at 37°C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Plate method (spread plate) PN-EN ISO 6888-1
7 Food E Presumptive Bacillus cereus count at 30°C
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Plate method (spread plate) PN-EN ISO 7932
8 Food E Presence of Salmonella sp. rods
Regulated area: E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.
Culture method with biochemical and serological confirmation PN-EN ISO 6579
9 Surowe mleko i przetwory mleczne, Poddane obróbce cieplnej mleko i przetwory mleczne, Surowe mięso i gotowe do ugotowania (z wyjątkiem drobiu), Gotowe do spożycia, gotowe do odgrzania produkty mięsne, Surowy drób i gotowe do ugotowania produkty z drobiu, Gotowe do spożycia, gotowe do odgrzania produkty z mięsa drobiowego, Jaja i produkty jajeczne (pochodne), Surowe i gotowe do ugotowania ryby i owoce morze nieprzetworzone, Gotowe do spożycia, gotowe do odgrzania produkty rybne, Świeże produkty rolne i owoce, Przetworzone owoce i warzywa, Suche zboża, owoce, orzechy, nasiona i warzywa, Preparaty dla niemowląt i płatki zbożowe dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Żywność wieloskładnikowa lub składniki posiłków Obecność Listera monocytogenes Culture method with biochemical confirmation PN-EN ISO 11290-1:2017-07
Oddział Laboratoryjny; Pracownia Badania Wody
10 Water intended for human consumption Water sampling for microbiological testing PN-EN ISO 19458:2007
11 Water Coagulase-positive staphylococci count Membrane filtration method Metodyka PZH ZHK Warszawa 2007 ,,Gronkowce koagulazododatnie”
12 Water Escherichia coli count MPN method PN-EN ISO 9308-3:2002
13 Water Ogólna liczba mikroorganizmów w temperaturze 36ºC po 48h i 24h Plate method (pour plate) PN-EN ISO 6222:2004
14 Water, Water intended for human consumption Pseudomonas aeruginosa bacteria count Membrane filtration method PN-EN ISO 16266:2009
15 Water, Water intended for human consumption Coliform bacteria and Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04
16 Water, Water intended for human consumption Liczba enterokoków kałowych/jelitowych Membrane filtration method PN-EN ISO 7899-2:2004
17 Water, Water intended for human consumption Count of bacteria of the genus Legionella sp. Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
18 Water intended for human consumption Ogólna liczba mikroorganizmów w temperaturze 22ºC po 72h Plate method (pour plate) PN-EN ISO 6222:2004
19 Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10
20 Water intended for human consumption pH
Range 4,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
21 Water intended for human consumption Electrical conductivity
Range (148 – 12900) μS/cm
Conductometric method PN-EN 27888:1999
22 Water intended for human consumption Ammonia concentration
Range (0,14 – 2,58) mg/dm3
Spectrophotometric method PN-C-04576-4:1994
23 Water, Water intended for human consumption Turbidity
Range (0,10 – 200) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
24 Water, Water intended for human consumption Permanganate index
Range (0,50 – 9,6) mg/dm3 O2
Titrimetric method PN-EN ISO 8467: 2001
25 Water, Water intended for human consumption Nitrate concentration
Range (0,7 – 105) mg/dm3
Spectrophotometric method PN-82/C-04576.08
26 Water intended for human consumption Iron concentration
Range (0,040 – 5,00) mg/dm3
Spectrophotometric method PN-ISO 6332:2001 + Ap1:2016-06
27 Water intended for human consumption Nitrite concentration
Range (0,02 – 0,82) mg/dm3
Spectrophotometric method PN-EN 26777:1999
28 Water intended for human consumption Manganese concentration
Range (0,040 – 1,0) mg/dm3
Spectrophotometric method PN-92/C-04590/02
29 Water intended for human consumption Total calcium and magnesium content (Total hardness)
Range (9 – 1200) mg/dm3 CaCO3
Titrimetric method PN-ISO 6059:1999
30 Water intended for human consumption, Swimming pool water Free chlorine concentration
Range (0,05 – 2,00) mg/l
Regulated area: Badania wykonywane poza siedzibą laboratorium
Spectrophotometric method Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014
31 Swimming pool water Total chlorine concentration
Range (0,05 – 2,00) mg/l
Regulated area: Badania wykonywane poza siedzibą laboratorium
Spectrophotometric method Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022
32 Swimming pool water Combined chlorine concentration (calculated)
Regulated area: Badania wykonywane poza siedzibą laboratorium
Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014 | Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022
33 Swimming pool water Oxidation-reduction potential (redox) vs. Ag/AgCl 3,5 mol KCl
Range (200 – 1000) mV
Regulated area: Badania wykonywane poza siedzibą laboratorium
Potentiometric method PB/PBW/01 wyd.2 z dnia 01.03.2019 r.
34 Swimming pool water pH
Range 4,0 – 9,2
Regulated area: Badania wykonywane poza siedzibą laboratorium
Potentiometric method PN-EN ISO 10523:2012
Oddział Laboratoryjny; Pracownia Bakteriologii
35 Faeces, rectal swab Presence of enteric rods of the genera Salmonella spp. and Shigella spp. Culture method with biochemical and serological confirmation PB/PB/01 wyd. 8 z dnia 28.02.2023 r. | na podstawie Metodyki NIZP-PZH
36 Faeces, rectal swab Obecność pałeczek jelitowych z rodzaju Salmonella Enteritidis Culture method with biochemical and serological confirmation PB/PB/01 wyd. 8 z dnia 28.02.2023 r. | na podstawie Metodyki NIZP-PZH
37 Biological indicators for monitoring the effectiveness of the sterilisation process (Sporal A) Presence of the indicator microorganism Geobacillus stearothermophilus Culture method PB/PB/02 wyd. 6 z dnia 28.02.2023 r. | na podstawie instrukcji producenta
38 Biological indicators for monitoring the effectiveness of the sterilisation process (Sporal S) Presence of the indicator microorganism Bacillus subtilis Culture method PB/PB/02 wyd. 6 z dnia 28.02.2023 r. | na podstawie instrukcji producenta
39 Faeces, rectal swab Obecność pałeczek jelitowych z rodzaju Yersinia enterocolitica Biochemical - culture method PB/PB/04 wyd. 5 z dnia 27.05.2026 r.

Reference standards (36)

Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014
Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022
Metodyka PZH ZHK Warszawa 2007 ,,Gronkowce koagulazododatnie”
PB/PB/01 wyd. 8 z dnia 28.02.2023 r.
PB/PB/02 wyd. 6 z dnia 28.02.2023 r.
PB/PB/04 wyd. 5 z dnia 27.05.2026 r.
PB/PBW/01 wyd.2 z dnia 01.03.2019 r.
PN-82/C-04576.08
PN-92/C-04590/02
PN-C-04576-4:1994
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 11290-1:2017-07
PN-EN ISO 11290-2
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007
PN-EN ISO 4833
PN-EN ISO 6222:2004
PN-EN ISO 6579
PN-EN ISO 6888-1
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7899-2:2004
PN-EN ISO 7932
PN-EN ISO 8467: 2001
PN-EN ISO 9308-1:2014-12 + A1:2017-04
PN-EN ISO 9308-3:2002
PN-ISO 16649-2
PN-ISO 21528-2
PN-ISO 4832
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001 + Ap1:2016-06
na podstawie Metodyki NIZP-PZH
na podstawie instrukcji producenta