{"lab":{"_id":"69ad52a3de79e566650fb328","accr_number":"AB 617","country":"PL","accr_body":"PCA","address":"W SANDOMIERZU, ul. Frankowskiego 8, 27-600 Sandomierz","categories":["water","microbiology","food"],"city":"Sandomierz","imported_at":"2026-03-08T10:42:43.265Z","methods_count":39,"name":"POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_617.pdf"],"scope_summary":"","search_text":"powiatowa stacja sanitarno-epidemiologiczna w sandomierzu, ul. frankowskiego 8, 27-600 sandomierz microbiology food other water automotive pharma electronics","status":"active","updated_at":"2026-03-08T14:51:31.081Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T21:00:31.796Z","email_confidence":"high","email_mx":true,"email_source":"https://bip.pca.gov.pl/wykazy-i-archiwa/akredytacje-aktywne/laboratoria-badawcze/AB%20617,podmiot.html","fields_of_testing":[{"codes":"C/28; C/29","pl":"Badania chemiczne wody, wody do spożycia przez ludzi","en":"Chemical tests of water, drinking water,"},{"codes":"K/3; K/22, K/28, K/29","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, żywności, wody, wody do spożycia przez ludzi","en":"Microbiological tests of biological items and materials for testing, food, water, drinking water"},{"codes":"N/28; N/29","pl":"Badania właściwości fizycznych wody, wody do spożycia przez ludzi","en":"Tests of physical properties of water, drinking water"},{"codes":"P/29","pl":"Pobieranie próbek woda do spożycia przez ludzi do badań chemicznych, fizycznych i mikrobiologicznych","en":"Sampling of drinking water for chemical, physical, and microbiological testing"}],"issue":{"no":"26","date":"21.07.2026"},"parse_date":"2026-08-17T21:00:31.796Z","parse_source":"agent-claude-code","map_coord":[50.690216,21.732059],"map_geo":"nominatim-street","lab_locations":[{"name":"Oddział Laboratoryjny","address":"ul. Frankowskiego 8, 27-600 Sandomierz","city":"Sandomierz","postal":"27-600"},{"name":"Pracownia Badania Żywności","address":"ul. Frankowskiego 8, 27-600 Sandomierz","city":"Sandomierz","postal":"27-600"},{"name":"Pracownia Badania Wody","address":"ul. Frankowskiego 8, 27-600 Sandomierz","city":"Sandomierz","postal":"27-600"},{"name":"Pracownia Bakteriologii","address":"ul. Frankowskiego 8, 27-600 Sandomierz","city":"Sandomierz","postal":"27-600"},{"name":"Oddział Laboratoryjny; Pracownia Badania Wody","address":null,"city":null,"postal":null},{"name":"Oddział Laboratoryjny; Pracownia Badania Żywności","address":null,"city":null,"postal":null},{"name":"Oddział Laboratoryjny; Pracownia Bakteriologii","address":null,"city":null,"postal":null}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/8c8fc18b591c3e65a700ef7584205442/AB%20617.pdf","has_en":true,"category_counts":{"water":25,"microbiology":15,"food":9,"other":1},"category_scores":{"water":12.5,"microbiology":4.5,"food":1.62,"other":0.02},"has_zh":true,"lab_locations_zh":[{"name":"Oddział Laboratoryjny","address":"ul. Frankowskiego 8, 27-600 Sandomierz","city":"Sandomierz","postal":"27-600"},{"name":"Pracownia Badania Żywności","address":"ul. Frankowskiego 8, 27-600 Sandomierz","city":"Sandomierz","postal":"27-600"},{"name":"水检测实验室","address":"ul. Frankowskiego 8, 27-600 Sandomierz","city":"Sandomierz","postal":"27-600"},{"name":"Pracownia Bakteriologii","address":"ul. Frankowskiego 8, 27-600 Sandomierz","city":"Sandomierz","postal":"27-600"},{"name":"Oddział Laboratoryjny; Pracownia Badania Wody","address":null,"city":null,"postal":null},{"name":"Oddział Laboratoryjny; Pracownia Badania Żywności","address":null,"city":null,"postal":null},{"name":"Oddział Laboratoryjny; Pracownia Bakteriologii","address":null,"city":null,"postal":null}]},"methods":[{"_id":"6a83766faf14b9c0e7b1f6ef","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba bakterii Enterobacteriaceae w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii Enterobacteriaceae w 37°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 21528-2","norm_bases":["PN-ISO 21528-2"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba bakterii Enterobacteriaceae w 37°C\nMetoda płytkowa (posiew wgłębny) PN-ISO 21528-2 Zywnosc E Liczba bakterii Enterobacteriaceae w 37°C\nMetoda plytkowa (posiew wglebny) PN-ISO 21528-2","categories":["food","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Enterobacteriaceae count at 37°C","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E Enterobacteriaceae count at 37°C Plate method (pour plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-ISO 21528-2","technique_en":"Plate method (pour plate)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E 平板法（倾注培养） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-ISO 21528-2","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E"},{"_id":"6a83766faf14b9c0e7b1f6f0","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba bakterii Listeria monocytogenes","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba bakterii Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 11290-2","norm_bases":["PN-EN ISO 11290-2"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba bakterii Listeria monocytogenes\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 11290-2 Zywnosc E Liczba bakterii Listeria monocytogenes\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 11290-2","categories":["microbiology","food"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Listeria monocytogenes count","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E Listeria monocytogenes count Plate method (spread plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 11290-2","technique_en":"Plate method (spread plate)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E 平板法（表面涂布） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 11290-2","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E"},{"_id":"6a83766faf14b9c0e7b1f6f1","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba bakterii z grupy coli w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii z grupy coli w 37°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 4832","norm_bases":["PN-ISO 4832"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba bakterii z grupy coli w 37°C\nMetoda płytkowa (posiew wgłębny) PN-ISO 4832 Zywnosc E Liczba bakterii z grupy coli w 37°C\nMetoda plytkowa (posiew wglebny) PN-ISO 4832","categories":["food","microbiology"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count at 37°C","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E Coliform bacteria count at 37°C Plate method (pour plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-ISO 4832","technique_en":"Plate method (pour plate)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E 平板法（倾注培养） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-ISO 4832","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E"},{"_id":"6a83766faf14b9c0e7b1f6f2","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Żywność E","methodology":"Ogólna liczba drobnoustrojów w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 4833","norm_bases":["PN-EN ISO 4833"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Ogólna liczba drobnoustrojów w 30°C\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 4833 Zywnosc E Ogolna liczba drobnoustrojow w 30°C\nMetoda plytkowa (posiew wglebny) PN-EN ISO 4833","categories":["food","microbiology"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 30°C","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E Total viable count at 30°C Plate method (pour plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 4833","technique_en":"Plate method (pour plate)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E 30°C 微生物总数 平板法（倾注培养） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 4833","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E","methodology_zh":"30°C 微生物总数"},{"_id":"6a83766faf14b9c0e7b1f6f3","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba bakterii β-glukuronidazododatnich Escherichia coli w 44°C","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba bakterii β-glukuronidazododatnich Escherichia coli w 44°C\nMetoda płytkowa (posiew wgłębny)","reference":"PN-ISO 16649-2","norm_bases":["PN-ISO 16649-2"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba bakterii β-glukuronidazododatnich Escherichia coli w 44°C\nMetoda płytkowa (posiew wgłębny) PN-ISO 16649-2 Zywnosc E Liczba bakterii β-glukuronidazododatnich Escherichia coli w 44°C\nMetoda plytkowa (posiew wglebny) PN-ISO 16649-2","categories":["microbiology","food"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E Plate method (pour plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-ISO 16649-2","technique_en":"Plate method (pour plate)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E 平板法（倾注培养） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-ISO 16649-2","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E"},{"_id":"6a83766faf14b9c0e7b1f6f4","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba gronkowców koagulazododatnich (Staphylococcus aureus i innych gatunków) w 37°C","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich (Staphylococcus aureus i innych gatunków) w 37°C\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 6888-1","norm_bases":["PN-EN ISO 6888-1"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba gronkowców koagulazododatnich (Staphylococcus aureus i innych gatunków) w 37°C\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 6888-1 Zywnosc E Liczba gronkowcow koagulazododatnich (Staphylococcus aureus i innych gatunkow) w 37°C\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 6888-1","categories":["food"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of coagulase-positive staphylococci (Staphylococcus aureus and other species) at 37°C","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E Count of coagulase-positive staphylococci (Staphylococcus aureus and other species) at 37°C Plate method (spread plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 6888-1","technique_en":"Plate method (spread plate)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E 平板法（表面涂布） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 6888-1","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E"},{"_id":"6a83766faf14b9c0e7b1f6f5","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba przypuszczalnych Bacillus cereus w 30°C","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba przypuszczalnych Bacillus cereus w 30°C\nMetoda płytkowa (posiew powierzchniowy)","reference":"PN-EN ISO 7932","norm_bases":["PN-EN ISO 7932"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba przypuszczalnych Bacillus cereus w 30°C\nMetoda płytkowa (posiew powierzchniowy) PN-EN ISO 7932 Zywnosc E Liczba przypuszczalnych Bacillus cereus w 30°C\nMetoda plytkowa (posiew powierzchniowy) PN-EN ISO 7932","categories":["food"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presumptive Bacillus cereus count at 30°C","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E Presumptive Bacillus cereus count at 30°C Plate method (spread plate) E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 7932","technique_en":"Plate method (spread plate)","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E 30°C 疑似蜡样芽孢杆菌计数 平板法（表面涂布） E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 7932","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E","methodology_zh":"30°C 疑似蜡样芽孢杆菌计数"},{"_id":"6a83766faf14b9c0e7b1f6f6","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność pałeczek Salmonella sp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność pałeczek Salmonella sp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PN-EN ISO 6579","norm_bases":["PN-EN ISO 6579"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Żywności","lab_address":null,"regulatory_area":"E – Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista działań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie lub na żądanie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność pałeczek Salmonella sp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579 Zywnosc E Obecnosc paleczek Salmonella sp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PN-EN ISO 6579","categories":["microbiology","food"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of Salmonella sp. rods","regulatory_area_en":"E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body.","search_en":"Food E Presence of Salmonella sp. rods Culture method with biochemical and serological confirmation E – Flexible scope of accreditation. Flexible scope includes the elements indicated in document DA-10 for the scope of accreditation of testing laboratories. A list of activities conducted under the flexible scope of accreditation shall be made publicly available or available on request by the accredited body. PN-EN ISO 6579","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Food E","regulatory_area_zh":"E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。","search_zh":"食品 E 培养法结合生化与血清学确认 E — 灵活的认可范围。范围的灵活性涵盖 DA-10 文件中针对检测实验室认可范围所列的要素。在灵活认可范围内开展的活动清单由获认可机构公开提供，或应要求提供。 PN-EN ISO 6579","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"食品 E"},{"_id":"6a83766faf14b9c0e7b1f6f7","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Surowe mleko i przetwory mleczne, Poddane obróbce cieplnej mleko i przetwory mleczne, Surowe mięso i gotowe do ugotowania (z wyjątkiem drobiu), Gotowe do spożycia, gotowe do odgrzania produkty mięsne, Surowy drób i gotowe do ugotowania produkty z drobiu, Gotowe do spożycia, gotowe do odgrzania produkty z mięsa drobiowego, Jaja i produkty jajeczne (pochodne), Surowe i gotowe do ugotowania ryby i owoce morze nieprzetworzone, Gotowe do spożycia, gotowe do odgrzania produkty rybne, Świeże produkty rolne i owoce, Przetworzone owoce i warzywa, Suche zboża, owoce, orzechy, nasiona i warzywa, Preparaty dla niemowląt i płatki zbożowe dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Żywność wieloskładnikowa lub składniki posiłków","methodology":"Obecność Listera monocytogenes","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność Listera monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"PN-EN ISO 11290-1:2017-07","norm_bases":["PN-EN ISO 11290-1:2017-07"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Żywności","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Surowe mleko i przetwory mleczne, Poddane obróbce cieplnej mleko i przetwory mleczne, Surowe mięso i gotowe do ugotowania (z wyjątkiem drobiu), Gotowe do spożycia, gotowe do odgrzania produkty mięsne, Surowy drób i gotowe do ugotowania produkty z drobiu, Gotowe do spożycia, gotowe do odgrzania produkty z mięsa drobiowego, Jaja i produkty jajeczne (pochodne), Surowe i gotowe do ugotowania ryby i owoce morze nieprzetworzone, Gotowe do spożycia, gotowe do odgrzania produkty rybne, Świeże produkty rolne i owoce, Przetworzone owoce i warzywa, Suche zboża, owoce, orzechy, nasiona i warzywa, Preparaty dla niemowląt i płatki zbożowe dla niemowląt, Czekolada, wyroby piekarnicze i cukiernicze, Żywność wieloskładnikowa lub składniki posiłków Obecność Listera monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07 Surowe mleko i przetwory mleczne, Poddane obrobce cieplnej mleko i przetwory mleczne, Surowe mieso i gotowe do ugotowania (z wyjatkiem drobiu), Gotowe do spozycia, gotowe do odgrzania produkty miesne, Surowy drob i gotowe do ugotowania produkty z drobiu, Gotowe do spozycia, gotowe do odgrzania produkty z miesa drobiowego, Jaja i produkty jajeczne (pochodne), Surowe i gotowe do ugotowania ryby i owoce morze nieprzetworzone, Gotowe do spozycia, gotowe do odgrzania produkty rybne, Swieze produkty rolne i owoce, Przetworzone owoce i warzywa, Suche zboza, owoce, orzechy, nasiona i warzywa, Preparaty dla niemowlat i platki zbozowe dla niemowlat, Czekolada, wyroby piekarnicze i cukiernicze, Zywnosc wieloskladnikowa lub skladniki posilkow Obecnosc Listera monocytogenes\nMetoda hodowlana z potwierdzeniem biochemicznym PN-EN ISO 11290-1:2017-07","categories":["food"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Culture method with biochemical confirmation PN-EN ISO 11290-1:2017-07","technique_en":"Culture method with biochemical confirmation","search_zh":"培养法结合生化确认 PN-EN ISO 11290-1:2017-07","technique_zh":"培养法结合生化确认"},{"_id":"6a83766faf14b9c0e7b1f6f8","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek wody do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek wody do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007","norm_bases":["PN-EN ISO 19458:2007"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek wody do badań mikrobiologicznych PN-EN ISO 19458:2007 Woda do spozycia przez ludzi Pobieranie probek wody do badan mikrobiologicznych PN-EN ISO 19458:2007","categories":["water","microbiology"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water sampling for microbiological testing","search_en":"Water intended for human consumption Water sampling for microbiological testing PN-EN ISO 19458:2007","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 用于微生物检验的水样采集 PN-EN ISO 19458:2007","test_object_zh":"生活饮用水","methodology_zh":"用于微生物检验的水样采集"},{"_id":"6a83766faf14b9c0e7b1f6f9","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda","methodology":"Liczba gronkowców koagulazododatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"Metodyka PZH ZHK Warszawa 2007 ,,Gronkowce koagulazododatnie”","norm_bases":["Metodyka PZH ZHK Warszawa 2007 ,,Gronkowce koagulazododatnie”"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej Metodyka PZH ZHK Warszawa 2007 ,,Gronkowce koagulazododatnie” Woda Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej Metodyka PZH ZHK Warszawa 2007 ,,Gronkowce koagulazododatnie”","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count","search_en":"Water Coagulase-positive staphylococci count Membrane filtration method Metodyka PZH ZHK Warszawa 2007 ,,Gronkowce koagulazododatnie”","technique_en":"Membrane filtration method","test_object_en":"Water","search_zh":"水 凝固酶阳性葡萄球菌计数 膜过滤法 Metodyka PZH ZHK Warszawa 2007 ,,Gronkowce koagulazododatnie”","technique_zh":"膜过滤法","test_object_zh":"水","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a83766faf14b9c0e7b1f6fa","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Liczba bakterii Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-3:2002","norm_bases":["PN-EN ISO 9308-3:2002"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii Escherichia coli\nMetoda NPL PN-EN ISO 9308-3:2002 Woda Liczba bakterii Escherichia coli\nMetoda NPL PN-EN ISO 9308-3:2002","categories":["microbiology","water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water Escherichia coli count MPN method PN-EN ISO 9308-3:2002","technique_en":"MPN method","test_object_en":"Water","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水 大肠埃希氏菌（Escherichia coli）计数 最可能数法（MPN） PN-EN ISO 9308-3:2002","technique_zh":"最可能数法（MPN）","test_object_zh":"水"},{"_id":"6a83766faf14b9c0e7b1f6fb","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36ºC po 48h i 24h","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36ºC po 48h i 24h\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w temperaturze 36ºC po 48h i 24h\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w temperaturze 36ºC po 48h i 24h\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water","search_zh":"水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水"},{"_id":"6a83766faf14b9c0e7b1f6fc","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda, Woda do spozycia przez ludzi Liczba bakterii Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water","microbiology"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa bacteria count","search_en":"Water, Water intended for human consumption Pseudomonas aeruginosa bacteria count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 铜绿假单胞菌数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"铜绿假单胞菌数"},{"_id":"6a83766faf14b9c0e7b1f6fd","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli i Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli i Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 + A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 + A1:2017-04"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii grupy coli i Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04 Woda, Woda do spozycia przez ludzi Liczba bakterii grupy coli i Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 + A1:2017-04","categories":["microbiology","water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria and Escherichia coli count","search_en":"Water, Water intended for human consumption Coliform bacteria and Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 大肠菌群数与大肠埃希氏菌数 膜过滤法 PN-EN ISO 9308-1:2014-12 + A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水","methodology_zh":"大肠菌群数与大肠埃希氏菌数"},{"_id":"6a83766faf14b9c0e7b1f6fe","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych/jelitowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych/jelitowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba enterokoków kałowych/jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda, Woda do spozycia przez ludzi Liczba enterokokow kalowych/jelitowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water, Water intended for human consumption Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83766faf14b9c0e7b1f6ff","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Liczba bakterii z rodzaju Legionella sp.","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella sp.\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019-12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019-12"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella sp.\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12 Woda, Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella sp.\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019-12","categories":["microbiology","water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of bacteria of the genus Legionella sp.","search_en":"Water, Water intended for human consumption Count of bacteria of the genus Legionella sp. Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_en":"Membrane filtration method","test_object_en":"Water, Water intended for human consumption","search_zh":"水、生活饮用水 膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019-12","technique_zh":"膜过滤法","test_object_zh":"水、生活饮用水"},{"_id":"6a83766faf14b9c0e7b1f700","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22ºC po 72h","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22ºC po 72h\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 22ºC po 72h\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 22ºC po 72h\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a83766faf14b9c0e7b1f701","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10","norm_bases":["PN-ISO 5667-5:2017-10"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 Woda do spozycia przez ludzi Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water intended for human consumption Sampling for chemical and physical testing PN-ISO 5667-5:2017-10","test_object_en":"Water intended for human consumption","methodology_zh":"化学与物理检测用样品采集","search_zh":"生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10","test_object_zh":"生活饮用水"},{"_id":"6a83766faf14b9c0e7b1f702","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 10,0"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres 4,0 – 10,0\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 10,0"}],"search_en":"Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 10,0"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a83766faf14b9c0e7b1f703","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(148 – 12900) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (148 – 12900) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (148 – 12900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (148 – 12900) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(148 – 12900) μS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(148 – 12900) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a83766faf14b9c0e7b1f704","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie amoniaku","parameters":[{"name":"Zakres","range":"(0,14 – 2,58) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie amoniaku\nZakres (0,14 – 2,58) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-C-04576-4:1994","norm_bases":["PN-C-04576-4:1994"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie amoniaku\nZakres (0,14 – 2,58) mg/dm3\nMetoda spektrofotometryczna PN-C-04576-4:1994 Woda do spozycia przez ludzi Stezenie amoniaku\nZakres (0,14 – 2,58) mg/dm3\nMetoda spektrofotometryczna PN-C-04576-4:1994","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia concentration","parameters_en":[{"name":"Range","range":"(0,14 – 2,58) mg/dm3"}],"search_en":"Water intended for human consumption Ammonia concentration Spectrophotometric method Range PN-C-04576-4:1994","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,14 – 2,58) mg/dm3"}],"search_zh":"生活饮用水 氨浓度 分光光度法 范围 PN-C-04576-4:1994","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"氨浓度"},{"_id":"6a83766faf14b9c0e7b1f705","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 – 200) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 – 200) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Mętność\nZakres (0,10 – 200) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda, Woda do spozycia przez ludzi Metnosc\nZakres (0,10 – 200) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 – 200) NTU"}],"search_en":"Water, Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 – 200) NTU"}],"search_zh":"水、生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水、生活饮用水"},{"_id":"6a83766faf14b9c0e7b1f706","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 – 9,6) mg/dm3 O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 – 9,6) mg/dm3 O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467: 2001","norm_bases":["PN-EN ISO 8467: 2001"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 9,6) mg/dm3 O2\nMetoda miareczkowa PN-EN ISO 8467: 2001 Woda, Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 – 9,6) mg/dm3 O2\nMetoda miareczkowa PN-EN ISO 8467: 2001","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 – 9,6) mg/dm3 O2"}],"search_en":"Water, Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467: 2001","technique_en":"Titrimetric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 – 9,6) mg/dm3 O2"}],"search_zh":"水、生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467: 2001","technique_zh":"滴定法","test_object_zh":"水、生活饮用水"},{"_id":"6a83766faf14b9c0e7b1f707","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda, Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,7 – 105) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,7 – 105) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,7 – 105) mg/dm3\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda, Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,7 – 105) mg/dm3\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,7 – 105) mg/dm3"}],"search_en":"Water, Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water, Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,7 – 105) mg/dm3"}],"search_zh":"水、生活饮用水 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水、生活饮用水"},{"_id":"6a83766faf14b9c0e7b1f708","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(0,040 – 5,00) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (0,040 – 5,00) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001 + Ap1:2016-06","norm_bases":["PN-ISO 6332:2001 + Ap1:2016-06"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (0,040 – 5,00) mg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (0,040 – 5,00) mg/dm3\nMetoda spektrofotometryczna PN-ISO 6332:2001 + Ap1:2016-06","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(0,040 – 5,00) mg/dm3"}],"search_en":"Water intended for human consumption Iron concentration Spectrophotometric method Range PN-ISO 6332:2001 + Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 5,00) mg/dm3"}],"search_zh":"生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001 + Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a83766faf14b9c0e7b1f709","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,02 – 0,82) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,02 – 0,82) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,02 – 0,82) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,02 – 0,82) mg/dm3\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,02 – 0,82) mg/dm3"}],"search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,02 – 0,82) mg/dm3"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a83766faf14b9c0e7b1f70a","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,040 – 1,0) mg/dm3"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,040 – 1,0) mg/dm3\nMetoda spektrofotometryczna","reference":"PN-92/C-04590/02","norm_bases":["PN-92/C-04590/02"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (0,040 – 1,0) mg/dm3\nMetoda spektrofotometryczna PN-92/C-04590/02 Woda do spozycia przez ludzi Stezenie manganu\nZakres (0,040 – 1,0) mg/dm3\nMetoda spektrofotometryczna PN-92/C-04590/02","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,040 – 1,0) mg/dm3"}],"search_en":"Water intended for human consumption Manganese concentration Spectrophotometric method Range PN-92/C-04590/02","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,040 – 1,0) mg/dm3"}],"search_zh":"生活饮用水 锰浓度 分光光度法 范围 PN-92/C-04590/02","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a83766faf14b9c0e7b1f70b","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (Twardość ogólna)","parameters":[{"name":"Zakres","range":"(9 – 1200) mg/dm3 CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (Twardość ogólna)\nZakres (9 – 1200) mg/dm3 CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (Twardość ogólna)\nZakres (9 – 1200) mg/dm3 CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (Twardosc ogolna)\nZakres (9 – 1200) mg/dm3 CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total calcium and magnesium content (Total hardness)","parameters_en":[{"name":"Range","range":"(9 – 1200) mg/dm3 CaCO3"}],"search_en":"Water intended for human consumption Total calcium and magnesium content (Total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(9 – 1200) mg/dm3 CaCO3"}],"search_zh":"生活饮用水 钙与镁总含量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水","methodology_zh":"钙与镁总含量（总硬度）"},{"_id":"6a83766faf14b9c0e7b1f70c","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014","norm_bases":["Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Stężenie chloru wolnego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014 Woda do spozycia przez ludzi, Woda na plywalniach Stezenie chloru wolnego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014","categories":["water"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,00) mg/l"}],"search_en":"Water intended for human consumption, Swimming pool water Free chlorine concentration Spectrophotometric method Range Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption, Swimming pool water","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 – 2,00) mg/l"}],"search_zh":"生活饮用水、游泳池水 游离氯浓度 分光光度法 范围 Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014","technique_zh":"分光光度法","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a83766faf14b9c0e7b1f70d","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru ogólnego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna","reference":"Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022","norm_bases":["Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda na pływalniach Stężenie chloru ogólnego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022 Woda na plywalniach Stezenie chloru ogolnego\nZakres (0,05 – 2,00) mg/l\nMetoda spektrofotometryczna Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022","categories":["water"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,00) mg/l"}],"search_en":"Swimming pool water Total chlorine concentration Spectrophotometric method Range Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022","technique_en":"Spectrophotometric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(0,05 – 2,00) mg/l"}],"search_zh":"游泳池水 总氯浓度 分光光度法 范围 Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022","technique_zh":"分光光度法","test_object_zh":"游泳池水","methodology_zh":"总氯浓度"},{"_id":"6a83766faf14b9c0e7b1f70e","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014 | Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022","norm_bases":["Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014","Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda na pływalniach Stężenie chloru związanego (z obliczeń) Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014 | Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022 Woda na plywalniach Stezenie chloru zwiazanego (z obliczen) Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014 | Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined chlorine concentration (calculated)","search_en":"Swimming pool water Combined chlorine concentration (calculated) Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014 | Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022","test_object_en":"Swimming pool water","search_zh":"游泳池水 化合氯浓度（计算值） Aplikacja HACH : Metoda 8021 edycja 9 z 01/2014 | Aplikacja HACH : Metoda 8167 edycja 11 z 01/2022","test_object_zh":"游泳池水","methodology_zh":"化合氯浓度（计算值）"},{"_id":"6a83766faf14b9c0e7b1f70f","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol KCl","parameters":[{"name":"Zakres","range":"(200 – 1000) mV"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol KCl\nZakres (200 – 1000) mV\nMetoda potencjometryczna","reference":"PB/PBW/01 wyd.2 z dnia 01.03.2019 r.","norm_bases":["PB/PBW/01 wyd.2 z dnia 01.03.2019 r."],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda na pływalniach Potencjał utleniająco-redukujący (redoks) wzgl. Ag/AgCl 3,5 mol KCl\nZakres (200 – 1000) mV\nMetoda potencjometryczna PB/PBW/01 wyd.2 z dnia 01.03.2019 r. Woda na plywalniach Potencjal utleniajaco-redukujacy (redoks) wzgl. Ag/AgCl 3,5 mol KCl\nZakres (200 – 1000) mV\nMetoda potencjometryczna PB/PBW/01 wyd.2 z dnia 01.03.2019 r.","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Oxidation-reduction potential (redox) vs. Ag/AgCl 3,5 mol KCl","parameters_en":[{"name":"Range","range":"(200 – 1000) mV"}],"search_en":"Swimming pool water Oxidation-reduction potential (redox) vs. Ag/AgCl 3,5 mol KCl Potentiometric method Range PB/PBW/01 wyd.2 z dnia 01.03.2019 r.","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","parameters_zh":[{"name":"范围","range":"(200 – 1000) mV"}],"search_zh":"游泳池水 电位法 范围 PB/PBW/01 wyd.2 z dnia 01.03.2019 r.","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a83766faf14b9c0e7b1f710","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"pH","parameters":[{"name":"Zakres","range":"4,0 – 9,2"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres 4,0 – 9,2\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Laboratoryjny; Pracownia Badania Wody","lab_address":null,"regulatory_area":"Badania wykonywane poza siedzibą laboratorium","flexible":false,"search_text":"Woda na pływalniach pH\nZakres 4,0 – 9,2\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda na plywalniach pH\nZakres 4,0 – 9,2\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"4,0 – 9,2"}],"search_en":"Swimming pool water pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Swimming pool water","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"4,0 – 9,2"}],"search_zh":"游泳池水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"游泳池水"},{"_id":"6a83766faf14b9c0e7b1f711","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","methodology":"Obecność pałeczek jelitowych z rodzaju Salmonella spp. i Shigella spp.","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność pałeczek jelitowych z rodzaju Salmonella spp. i Shigella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB/PB/01 wyd. 8 z dnia 28.02.2023 r. | na podstawie Metodyki NIZP-PZH","norm_bases":["PB/PB/01 wyd. 8 z dnia 28.02.2023 r.","na podstawie Metodyki NIZP-PZH"],"lab_section":"Oddział Laboratoryjny; Pracownia Bakteriologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu Obecność pałeczek jelitowych z rodzaju Salmonella spp. i Shigella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/PB/01 wyd. 8 z dnia 28.02.2023 r. | na podstawie Metodyki NIZP-PZH Kal, wymaz z odbytu Obecnosc paleczek jelitowych z rodzaju Salmonella spp. i Shigella spp.\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/PB/01 wyd. 8 z dnia 28.02.2023 r. | na podstawie Metodyki NIZP-PZH","categories":["microbiology"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of enteric rods of the genera Salmonella spp. and Shigella spp.","search_en":"Faeces, rectal swab Presence of enteric rods of the genera Salmonella spp. and Shigella spp. Culture method with biochemical and serological confirmation PB/PB/01 wyd. 8 z dnia 28.02.2023 r. | na podstawie Metodyki NIZP-PZH","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces, rectal swab","search_zh":"粪便、肛拭子 培养法结合生化与血清学确认 PB/PB/01 wyd. 8 z dnia 28.02.2023 r. | na podstawie Metodyki NIZP-PZH","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"粪便、肛拭子"},{"_id":"6a83766faf14b9c0e7b1f712","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","methodology":"Obecność pałeczek jelitowych z rodzaju Salmonella Enteritidis","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność pałeczek jelitowych z rodzaju Salmonella Enteritidis\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB/PB/01 wyd. 8 z dnia 28.02.2023 r. | na podstawie Metodyki NIZP-PZH","norm_bases":["PB/PB/01 wyd. 8 z dnia 28.02.2023 r.","na podstawie Metodyki NIZP-PZH"],"lab_section":"Oddział Laboratoryjny; Pracownia Bakteriologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu Obecność pałeczek jelitowych z rodzaju Salmonella Enteritidis\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/PB/01 wyd. 8 z dnia 28.02.2023 r. | na podstawie Metodyki NIZP-PZH Kal, wymaz z odbytu Obecnosc paleczek jelitowych z rodzaju Salmonella Enteritidis\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB/PB/01 wyd. 8 z dnia 28.02.2023 r. | na podstawie Metodyki NIZP-PZH","categories":["microbiology"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Faeces, rectal swab Culture method with biochemical and serological confirmation PB/PB/01 wyd. 8 z dnia 28.02.2023 r. | na podstawie Metodyki NIZP-PZH","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces, rectal swab","search_zh":"粪便、肛拭子 培养法结合生化与血清学确认 PB/PB/01 wyd. 8 z dnia 28.02.2023 r. | na podstawie Metodyki NIZP-PZH","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"粪便、肛拭子"},{"_id":"6a83766faf14b9c0e7b1f713","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Biologiczne wskaźniki kontroli skuteczności procesu sterylizacji (Sporal A)","methodology":"Obecność drobnoustroju wskaźnikowego Geobacillus stearothermophilus","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność drobnoustroju wskaźnikowego Geobacillus stearothermophilus\nMetoda hodowlana","reference":"PB/PB/02 wyd. 6 z dnia 28.02.2023 r. | na podstawie instrukcji producenta","norm_bases":["PB/PB/02 wyd. 6 z dnia 28.02.2023 r.","na podstawie instrukcji producenta"],"lab_section":"Oddział Laboratoryjny; Pracownia Bakteriologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biologiczne wskaźniki kontroli skuteczności procesu sterylizacji (Sporal A) Obecność drobnoustroju wskaźnikowego Geobacillus stearothermophilus\nMetoda hodowlana PB/PB/02 wyd. 6 z dnia 28.02.2023 r. | na podstawie instrukcji producenta Biologiczne wskazniki kontroli skutecznosci procesu sterylizacji (Sporal A) Obecnosc drobnoustroju wskaznikowego Geobacillus stearothermophilus\nMetoda hodowlana PB/PB/02 wyd. 6 z dnia 28.02.2023 r. | na podstawie instrukcji producenta","categories":["microbiology"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of the indicator microorganism Geobacillus stearothermophilus","search_en":"Biological indicators for monitoring the effectiveness of the sterilisation process (Sporal A) Presence of the indicator microorganism Geobacillus stearothermophilus Culture method PB/PB/02 wyd. 6 z dnia 28.02.2023 r. | na podstawie instrukcji producenta","technique_en":"Culture method","test_object_en":"Biological indicators for monitoring the effectiveness of the sterilisation process (Sporal A)","search_zh":"指示微生物嗜热脂肪土芽孢杆菌的检出 培养法 PB/PB/02 wyd. 6 z dnia 28.02.2023 r. | na podstawie instrukcji producenta","technique_zh":"培养法","methodology_zh":"指示微生物嗜热脂肪土芽孢杆菌的检出"},{"_id":"6a83766faf14b9c0e7b1f714","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Biologiczne wskaźniki kontroli skuteczności procesu sterylizacji (Sporal S)","methodology":"Obecność drobnoustroju wskaźnikowego Bacillus subtilis","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność drobnoustroju wskaźnikowego Bacillus subtilis\nMetoda hodowlana","reference":"PB/PB/02 wyd. 6 z dnia 28.02.2023 r. | na podstawie instrukcji producenta","norm_bases":["PB/PB/02 wyd. 6 z dnia 28.02.2023 r.","na podstawie instrukcji producenta"],"lab_section":"Oddział Laboratoryjny; Pracownia Bakteriologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biologiczne wskaźniki kontroli skuteczności procesu sterylizacji (Sporal S) Obecność drobnoustroju wskaźnikowego Bacillus subtilis\nMetoda hodowlana PB/PB/02 wyd. 6 z dnia 28.02.2023 r. | na podstawie instrukcji producenta Biologiczne wskazniki kontroli skutecznosci procesu sterylizacji (Sporal S) Obecnosc drobnoustroju wskaznikowego Bacillus subtilis\nMetoda hodowlana PB/PB/02 wyd. 6 z dnia 28.02.2023 r. | na podstawie instrukcji producenta","categories":["microbiology"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of the indicator microorganism Bacillus subtilis","search_en":"Biological indicators for monitoring the effectiveness of the sterilisation process (Sporal S) Presence of the indicator microorganism Bacillus subtilis Culture method PB/PB/02 wyd. 6 z dnia 28.02.2023 r. | na podstawie instrukcji producenta","technique_en":"Culture method","test_object_en":"Biological indicators for monitoring the effectiveness of the sterilisation process (Sporal S)","search_zh":"指示微生物枯草芽孢杆菌的检出 培养法 PB/PB/02 wyd. 6 z dnia 28.02.2023 r. | na podstawie instrukcji producenta","technique_zh":"培养法","methodology_zh":"指示微生物枯草芽孢杆菌的检出"},{"_id":"6a83766faf14b9c0e7b1f715","lab_id":"69ad52a3de79e566650fb328","country":"PL","accr_number":"AB 617","accr_body":"PCA","test_object":"Kał, wymaz z odbytu","methodology":"Obecność pałeczek jelitowych z rodzaju Yersinia enterocolitica","parameters":[],"technique":"Metoda biochemiczno - hodowlana","techniques":["Metoda biochemiczno - hodowlana"],"computed":[],"activity":"Obecność pałeczek jelitowych z rodzaju Yersinia enterocolitica\nMetoda biochemiczno - hodowlana","reference":"PB/PB/04 wyd. 5 z dnia 27.05.2026 r.","norm_bases":["PB/PB/04 wyd. 5 z dnia 27.05.2026 r."],"lab_section":"Oddział Laboratoryjny; Pracownia Bakteriologii","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, wymaz z odbytu Obecność pałeczek jelitowych z rodzaju Yersinia enterocolitica\nMetoda biochemiczno - hodowlana PB/PB/04 wyd. 5 z dnia 27.05.2026 r. Kal, wymaz z odbytu Obecnosc paleczek jelitowych z rodzaju Yersinia enterocolitica\nMetoda biochemiczno - hodowlana PB/PB/04 wyd. 5 z dnia 27.05.2026 r.","categories":["other"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Faeces, rectal swab Biochemical - culture method PB/PB/04 wyd. 5 z dnia 27.05.2026 r.","technique_en":"Biochemical - culture method","test_object_en":"Faeces, rectal swab","search_zh":"粪便、肛拭子 PB/PB/04 wyd. 5 z dnia 27.05.2026 r.","test_object_zh":"粪便、肛拭子"}],"has_pdf":true}