🇵🇱 „AQUA” Spółka Akcyjna PL

PCA AB 610 • Bielsko-Biała, Poland • 78 methods

Water & wastewaterMicrobiologyMaterials & polymers

„AQUA” Spółka Akcyjna is a laboratory accredited by PCA under number AB 610 (Bielsko-Biała, Poland). Its accreditation scope covers 78 test methods in the following areas: Water & wastewater, Microbiology, Materials & polymers. Test objects include: Water, Wastewater, Water (including swimming pool water), Sewage sludge. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.

At a glance

  • Accreditation number: PCA AB 610
  • Methods in scope: 78
  • Types of test objects: 8
  • Techniques used: 20
  • City: Bielsko-Biała, Poland
Accreditation number
AB 610
Accreditation body
PCA
Address
ul. 1-go Maja 23, 43-300 Bielsko-Biała
City
Bielsko-Biała, Poland

What this laboratory tests (8)

Analytical techniques used (20)

Laboratory sections (3)

Laboratory locations

Accreditation scope — test methods (78)

No. Test object Methodology / Parameters Technique Reference document
Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna
1 Water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.2, 4.4.3, 4.4.5, 4.4.6
2 Water Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6 i 8.2
3 Water Colour
Range (0 - 70) mg Pt/l
Visual method PN-EN ISO 7887:2012 Metoda D + Ap1:2015-06
4 Water Fluoride concentration
Range (0,10 - 5,0) mg/l
Potentiometric method PN-78/C-04588/03
5 Water Electrical conductivity
Range (10 - 12880) μS/cm
Conductometric method PN-EN 27888:1999
6 Water Total iron concentration
Range (0,020 - 3,5) mg/l
Spectrophotometric method PN-73/C-04586/03
7 Water Manganese concentration
Range (0,020 - 0,6) mg/l
Spectrophotometric method PB/UC/05 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8149
8 Water Total content of calcium and magnesium (total hardness)
Range (10 - 500) mg/l CaCO3
Titrimetric method PN-ISO 6059:1999
9 Water Chloride concentration
Range (5,0 – 250) mg/l
Titrimetric method PN-ISO 9297:1994
10 Water Total alkalinity
Range (0,2 - 20) mval/l
Titrimetric method PN-EN ISO 9963-1:2001 + Ap1:2004
11 Water Ammonia (ammonium ion) concentration
Range (0,10 - 2,0) mg/l NH4+
Spectrophotometric method PN-ISO 7150-1:2002
12 Water Nitrite concentration
Range (0,002 - 0,800) mg/l
Spectrophotometric method PN-EN 26777:1999
13 Water Chemical oxygen demand (COD-Cr)
Range (10,0 - 150) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
14 Water BOD5
Range (0,5 – 6,0) mg/l O2
Optical method PB/UC/51 wydanie 2 z 30.11.2012 r.
15 Water Orthophosphate concentration
Range (0,050 - 1,00) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010
16 Water Total phosphorus concentration
Range (0,10 - 2,00) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt 7 +Ap1:2010 +Ap2:2010
17 Water Sulfate concentration
Range (5,0 – 250) mg/l
Turbidimetric method PB/UC/11 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8051
18 Water Total suspended solids (TSS)
Range (5,0 - 500) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
19 Water (including swimming pool water) pH
Range (4,0 - 10,0)
Potentiometric method PN-EN ISO 10523:2012
20 Water (including swimming pool water) Turbidity
Range (0,10 - 400) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
21 Water (including swimming pool water) Permanganate index
Range (0,50 - 50) mg/l O2
Titrimetric method PN-EN ISO 8467:2001
22 Water (including swimming pool water) Nitrate concentration
Range (3,0 - 60) mg/l
Spectrophotometric method PN-82/C-04576.08
23 Water (including swimming pool water) Free chlorine concentration
Range (0,05 - 2,00) mg/l
Spectrophotometric method PB/UC/25 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8021
24 Water (including swimming pool water) Total chlorine concentration
Range (0,05 – 2,0) mg/l
Spectrophotometric method PB/UC/57 wyd. 1 z 01.12.2016
25 Water (including swimming pool water) Combined chlorine concentration (calculated) PB/UC/57 wyd. 1 z 01.12.2016
26 Water (including swimming pool water), wastewater Concentration of volatile halogenated hydrocarbon derivatives:
Range trichloromethane (chloroform) (1,0 - 200) μg/l bromodichloromethane (1,0 - 100) μg/l dibromochloromethane (1,0 - 100) μg/l tribromomethane (bromoform) (1,0 - 100) μg/l
Gas chromatography with headspace analysis with electron capture detection (GC-ECD) PN-EN ISO 10301:2002
27 Water (including swimming pool water), wastewater Concentration of total THM (calculated)
Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna
28 Water Total viable count at 22°C Plate method, pour plate PN-EN ISO 6222:2004
29 Water Total count of microorganisms at 30°C Plate method, pour plate PB/UC/50 wydanie 1 z 16.08.2012 r.
30 Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
31 Water Coliform bacteria count MPN method (Colilert-18) PN-EN ISO 9308-2:2014-06
32 Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
33 Water Count of spores of sulphite-reducing anaerobes (Clostridia) Membrane filtration method PN-EN 26461-2:2001
34 Water Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016
35 Water (including swimming pool water) Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
36 Water (including swimming pool water) Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04
37 Water (including swimming pool water) Escherichia coli count MPN method (Colilert-18) PN-EN ISO 9308-2:2014-06
38 Water (including swimming pool water) Count of bacteria of the genus Legionella
Range od 1 jtk/100 ml Range od 1 jtk/1000 ml Matryca A; Procedura 5, pożywka A (BCYE) Procedura 6 i 7 pożywka B (BCYE+AB) lub C (GVPC lub MWY)
Membrane filtration method PN-EN ISO 11731:2017-08
39 Water (including swimming pool water) Count of bacteria of the genus Legionella
Range od 10 jtk/1 ml Range od 1000 jtk/100 ml Range od 10000 jtk/1000 ml Matryca A: Procedura 1 i 2, pożywka A (BCYE), B (BCYE+AB), C(GVPC lub MWY)
Plate method, spread plate PN-EN ISO 11731:2017-08
40 Water (including swimming pool water) Total viable count at 36°C Plate method, pour plate PN-EN ISO 6222:2004
41 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PB/UC/46 wydanie 1 z 30.12.2010 r.
Laboratorium Centralne; Laboratorium Analiz Ścieków
42 Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11
43 Wastewater Temperature
Range (1,0 – 50)°C
PB/RLS/24 wydanie 1 z 05.01.2012 r.
44 Wastewater pH
Range (1,0 - 12,0)
Potentiometric method PN-EN ISO 10523:2012
45 Wastewater Kjeldahl nitrogen concentration
Range (0,40 - 200) mg/l
Titrimetric method PN-EN 25663:2001
46 Wastewater Nitrate nitrogen concentration
Range (0,14 - 30,0) mg/l
Spectrophotometric method PN-82/C-04576.08
47 Wastewater Nitrite nitrogen concentration
Range (0,03 - 5,0) mg/l
Spectrophotometric method PN-EN 26777:1999
48 Wastewater Total nitrogen concentration (calculated) PB/RLS/14 wydanie 2 z 31.01.2012 r.
49 Wastewater Chemical oxygen demand (COD-Cr)
Range (10 - 7 000) mg/l O2
Titrimetric method PB/RLS/21 wydanie 2 z dnia 27.11.2012 r.
50 Wastewater Chemical oxygen demand (COD-Cr)
Range (30 - 50 000) mg/l O2
Titrimetric method PN-ISO 6060:2006
51 Wastewater Chemical oxygen demand (COD-Cr)
Range (10,0 - 1000) mg/l O2
Spectrophotometric method PN-ISO 15705:2005
52 Wastewater Total suspended solids (TSS)
Range (5,0 – 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
53 Wastewater Substances extractable with petroleum ether
Range (10 - 2000) mg/l
Gravimetric method PB/RLS/13 wydanie 2 z 20.01.2012 r.
54 Wastewater Anionic surfactants (Anionic detergents)
Range (0,2 – 20) mg/l
Spectrophotometric method PN-EN 903:2002
55 Wastewater Total phosphorus concentration
Range (0,10 - 50,0) mg/l
Spectrophotometric method PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010
56 Wastewater Ammonium nitrogen concentration
Range (1,0 - 1000) mg/l
Titrimetric method PN-ISO 5664:2002
57 Wastewater Sulfate concentration
Range (20 - 2500) mg/l
Gravimetric method PN-ISO 9280:2002
58 Wastewater Phenol index
Range (0,005 - 0,5) mg/l
Spectrophotometric method PN-ISO 6439:1994 metoda B
59 Wastewater Sum of metals (Cr, Zn, Cd, Cu, Ni, Pb) (calculated) PB/RLS/26 wydanie 1 z 30.11.2012 r.
60 Wastewater BOD5, BOD2+5
Range (1 – 2100) mg/l O2
Electrochemical method PN-EN ISO 5815-1:2019-12
61 Wastewater Chloride concentration
Range (5,0 – 1500) mg/l
Titrimetric method PN-ISO 9297:1994
62 Wastewater Chromium(VI) concentration
Range (0,010 – 5,0) mg/l
Spectrophotometric method PN-77/C-04604/08
63 Wastewater Metal concentrations:
Range Cd (0,001 - 100) mg/l Pb (0,005 - 100) mg/l Zn (0,020 - 100) mg/l Cr (0,005 - 100) mg/l Ni (0,002 - 100) mg/l Cu (0,020 - 100) mg/l Fe (0,020 - 10) mg/l Mn (0,010 - 10) mg/l Al (0,020 - 10) mg/l Ca (1 - 300) mg/l Mg (1 - 300) mg/l Na (1 - 300) mg/l K (1 - 300) mg/l B (0,1 – 20) mg/l Ba (0,010 – 20,0) mg/l Be (0,020 – 5,0) mg/l Co (0,010 – 5,0) mg/l Ag (0,002 – 0,5) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
64 Wastewater Metal concentrations:
Range Sb (0,001 – 0,5) mg/l As (0,001 – 0,5) mg/l Se (0,002 – 1,0) mg/l
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) PN-EN ISO 11885:2009
65 Water Kjeldahl nitrogen concentration
Range (0,40 – 5,0) mg/l
Titrimetric method PN-EN 25663:2001
66 Water Metal concentrations:
Range Cd (0,001 - 10) mg/l Pb (0,005 - 10) mg/l Zn (0,020 - 10) mg/l Cr (0,005 - 10) mg/l Ni (0,002 - 10) mg/l Cu (0,020 - 10) mg/l Fe (0,020 - 10) mg/l Mn (0,010 - 10) mg/l Al (0,020 - 10) mg/l Ca (1 - 300) mg/l Mg (1 - 300) mg/l Na (1 - 300) mg/l K (1 - 300) mg/l B (0,1 – 5,0) mg/l Ba (0,010 – 5,0) mg/l Be (0,020 – 5,0) mg/l Co (0,010 – 5,0) mg/l Ag (0,002 – 0,5) mg/l
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009
67 Water Metal concentrations:
Range Sb (0,001 – 0,5) mg/l As (0,001 – 0,5) mg/l Se (0,002 – 1,0) mg/l
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) PN-EN ISO 11885:2009
68 Water, wastewater Mercury concentration
Range (0,0003 – 0,10) mg/l
Atomic absorption spectrometry with amalgamation technique PB/RLS/25 wydanie 1 z 15.06.2012 r.
69 Rainwater and snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
70 Rainwater and snowmelt water Total suspended solids (TSS)
Range (5,0 - 2000) mg/l
Gravimetric method PN-EN 872:2007+Ap1:2007
71 Sewage sludge pH
Range (4,0 – 10,0)
Potentiometric method PN-EN 12176:2004
72 Sewage sludge Sucha masa / Zawartośc wody
Range (0,5 - 99,5)%
Gravimetric method PN-EN 12880:2004
73 Sewage sludge Strata przy prażeniu suchej masy / Pozostałość po prażeniu
Range (0,5 - 99,5)%
Gravimetric method PN-EN 12879:2004
74 Sewage sludge Ammonium nitrogen content
Range (0,1 - 5,0)%
Titrimetric method PN-75/C-04576/15
75 Sewage sludge Total Kjeldahl nitrogen content
Range (0,10 - 10)%
Titrimetric method PN-EN 13342:2002
76 Sewage sludge Total phosphorus content
Range (1,0 – 5,0)%
Spectrophotometric method PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt 4 +Ap1:2010 + Ap2:2010
77 Sewage sludge Metal content
Range Chromium (5 - 3000) mg/kg Lead (5 - 2000) mg/kg Zinc (20 - 7000) mg/kg Cadmium (1 - 100) mg/kg Nickel (5 - 1000) mg/kg Copper (20 - 4000) mg/kg Calcium (1 - 60)% Magnesium (0,2 - 10)%
Inductively coupled plasma optical emission spectrometry (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 13346:2002
78 Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011, z wyłączeniem pkt 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.9, 6.3.10

Reference standards (65)

PB/RLS/13 wydanie 2 z 20.01.2012 r.
PB/RLS/14 wydanie 2 z 31.01.2012 r.
PB/RLS/21 wydanie 2 z dnia 27.11.2012 r.
PB/RLS/24 wydanie 1 z 05.01.2012 r.
PB/RLS/25 wydanie 1 z 15.06.2012 r.
PB/RLS/26 wydanie 1 z 30.11.2012 r.
PB/UC/05 wydanie 1 z 10.02.2004 r.
PB/UC/11 wydanie 1 z 10.02.2004 r.
PB/UC/25 wydanie 1 z 10.02.2004 r.
PB/UC/46 wydanie 1 z 30.12.2010 r.
PB/UC/50 wydanie 1 z 16.08.2012 r.
PB/UC/51 wydanie 2 z 30.11.2012 r.
PB/UC/57 wyd. 1 z 01.12.2016
PN-73/C-04586/03
PN-75/C-04576/15
PN-77/C-04604/08
PN-78/C-04588/03
PN-82/C-04576.08
PN-EN 12176:2004
PN-EN 12879:2004
PN-EN 12880:2004
PN-EN 13342:2002
PN-EN 13346:2002
PN-EN 14672:2006
PN-EN 25663:2001
PN-EN 26461-2:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN 903:2002
PN-EN ISO 10301:2002
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08
PN-EN ISO 11885:2009
PN-EN ISO 14189:2016
PN-EN ISO 16266:2009
PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.2, 4.4.3, 4.4.5, 4.4.6
PN-EN ISO 5667-13:2011, z wyłączeniem pkt 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.9, 6.3.10
PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6 i 8.2
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 pkt 4 +Ap1:2010 + Ap2:2010
PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010
PN-EN ISO 6878:2006 pkt 7 +Ap1:2010 +Ap2:2010
PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 Metoda D + Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9963-1:2001 + Ap1:2004
PN-ISO 15705:2005
PN-ISO 5664:2002
PN-ISO 5667-10:2021-11
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6060:2006
PN-ISO 6439:1994 metoda B
PN-ISO 7150-1:2002
PN-ISO 9280:2002
PN-ISO 9297:1994
na podstawie testu Hach nr 8021
na podstawie testu Hach nr 8051
na podstawie testu Hach nr 8149