{"lab":{"_id":"69ad52a3de79e566650fb320","accr_number":"AB 610","country":"PL","accr_body":"PCA","address":"ul. 1-go Maja 23, 43-300 Bielsko-Biała","categories":["water","microbiology","materials"],"city":"Bielsko-Biała","imported_at":"2026-03-08T10:42:43.265Z","methods_count":78,"name":"„AQUA” Spółka Akcyjna","parse_status":"parsed","parse_version":2,"pdf_files":["AB_610.pdf"],"scope_summary":"","search_text":"„aqua” spółka akcyjna ul. 1-go maja 23, 43-300 bielsko-biała water other pharma electronics microbiology automotive materials","status":"active","updated_at":"2026-03-08T14:51:30.748Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T21:03:59.917Z","email_confidence":"high","email_mx":true,"email_source":"https://www.aqua.com.pl/contact/laboratorium-woda","fields_of_testing":[{"codes":"C/28/P; C/29/P; C/30/P; C/32/P","pl":"Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Chemical tests and sampling of water, drinking water, sewage, sediments"},{"codes":"N/28/P; N/29/P; N/30/P; N/32/P","pl":"Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków, osadów","en":"Physical properties and sampling of water, drinking water, sewage, sediments"},{"codes":"K/28/P; K/29/P","pl":"Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi","en":"Microbiological tests and sampling of water, drinking water"},{"codes":"K/30","pl":"Badania mikrobiologiczne ścieków","en":"Microbiological tests of sewage"}],"issue":{"no":"21","date":"05.05.2026"},"parse_date":"2026-08-17T21:03:59.917Z","parse_source":"agent-claude-code","map_coord":[49.822118,19.044894],"map_geo":"nominatim-city","lab_locations":[{"name":"Laboratorium Centralne","address":"ul. Wodociągowa 8, 43-356 Kobiernice","city":"Kobiernice","postal":"43-356"},{"name":"Laboratorium Analiz Wody","address":"ul. Wodociągowa 8, 43-356 Kobiernice","city":"Kobiernice","postal":"43-356"},{"name":"Pracownia Fizyko-Chemiczna","address":"ul. Wodociągowa 8, 43-356 Kobiernice","city":"Kobiernice","postal":"43-356"},{"name":"Pracownia Mikrobiologiczna","address":"ul. Wodociągowa 8, 43-356 Kobiernice","city":"Kobiernice","postal":"43-356"},{"name":"Laboratorium Analiz Ścieków","address":"ul. Bestwińska 63, 43-300 Bielsko-Biała","city":"Bielsko-Biała","postal":"43-300"}],"scope_format":"PCA::pracownie+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/8f83e73f6f122c847ce35dc8c8bb398f/AB%20610.pdf","has_en":true,"category_counts":{"water":78,"microbiology":7,"materials":6},"category_scores":{"water":66.86,"microbiology":0.54,"materials":0.4},"has_zh":true},"methods":[{"_id":"6a83773faf14b9c0e7b1f751","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań mikrobiologicznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań mikrobiologicznych","reference":"PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.2, 4.4.3, 4.4.5, 4.4.6","norm_bases":["PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.2, 4.4.3, 4.4.5, 4.4.6"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań mikrobiologicznych PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.2, 4.4.3, 4.4.5, 4.4.6 Woda Pobieranie probek do badan mikrobiologicznych PN-EN ISO 19458:2007 z wylaczeniem pkt 4.4.2, 4.4.3, 4.4.5, 4.4.6","categories":["water","microbiology"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for microbiological testing","search_en":"Water Sampling for microbiological testing PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.2, 4.4.3, 4.4.5, 4.4.6","test_object_en":"Water","methodology_zh":"微生物检测用样品采集","search_zh":"水 微生物检测用样品采集 PN-EN ISO 19458:2007 z wyłączeniem pkt 4.4.2, 4.4.3, 4.4.5, 4.4.6","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f752","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6 i 8.2","norm_bases":["PN-ISO 5667-5:2017-10","PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6 i 8.2"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Pobieranie próbek do badań chemicznych i fizycznych PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6 i 8.2 Woda Pobieranie probek do badan chemicznych i fizycznych PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 z wylaczeniem pkt 7.5, 7.6 i 8.2","categories":["water"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Water Sampling for chemical and physical testing PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6 i 8.2","test_object_en":"Water","methodology_zh":"化学与物理检测用样品采集","search_zh":"水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10 | PN-EN ISO 5667-6:2016-12 z wyłączeniem pkt 7.5, 7.6 i 8.2","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f753","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(0 - 70) mg Pt/l"}],"technique":"Metoda wizualna","techniques":["Metoda wizualna"],"computed":[],"activity":"Barwa\nZakres (0 - 70) mg Pt/l\nMetoda wizualna","reference":"PN-EN ISO 7887:2012 Metoda D + Ap1:2015-06","norm_bases":["PN-EN ISO 7887:2012 Metoda D + Ap1:2015-06"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Barwa\nZakres (0 - 70) mg Pt/l\nMetoda wizualna PN-EN ISO 7887:2012 Metoda D + Ap1:2015-06 Woda Barwa\nZakres (0 - 70) mg Pt/l\nMetoda wizualna PN-EN ISO 7887:2012 Metoda D + Ap1:2015-06","categories":["water"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(0 - 70) mg Pt/l"}],"search_en":"Water Colour Visual method Range PN-EN ISO 7887:2012 Metoda D + Ap1:2015-06","technique_en":"Visual method","test_object_en":"Water","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(0 - 70) mg Pt/l"}],"search_zh":"水 色度 目视法 范围 PN-EN ISO 7887:2012 Metoda D + Ap1:2015-06","technique_zh":"目视法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f754","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie fluorków","parameters":[{"name":"Zakres","range":"(0,10 - 5,0) mg/l"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"Stężenie fluorków\nZakres (0,10 - 5,0) mg/l\nMetoda potencjometryczna","reference":"PN-78/C-04588/03","norm_bases":["PN-78/C-04588/03"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie fluorków\nZakres (0,10 - 5,0) mg/l\nMetoda potencjometryczna PN-78/C-04588/03 Woda Stezenie fluorkow\nZakres (0,10 - 5,0) mg/l\nMetoda potencjometryczna PN-78/C-04588/03","categories":["water"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluoride concentration","parameters_en":[{"name":"Range","range":"(0,10 - 5,0) mg/l"}],"search_en":"Water Fluoride concentration Potentiometric method Range PN-78/C-04588/03","technique_en":"Potentiometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,10 - 5,0) mg/l"}],"search_zh":"水 氟化物浓度 电位法 范围 PN-78/C-04588/03","technique_zh":"电位法","test_object_zh":"水","methodology_zh":"氟化物浓度"},{"_id":"6a83773faf14b9c0e7b1f755","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(10 - 12880) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (10 - 12880) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Przewodność elektryczna właściwa\nZakres (10 - 12880) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda Przewodnosc elektryczna wlasciwa\nZakres (10 - 12880) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(10 - 12880) μS/cm"}],"search_en":"Water Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(10 - 12880) μS/cm"}],"search_zh":"水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f756","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,020 - 3,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,020 - 3,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-73/C-04586/03","norm_bases":["PN-73/C-04586/03"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie żelaza ogólnego\nZakres (0,020 - 3,5) mg/l\nMetoda spektrofotometryczna PN-73/C-04586/03 Woda Stezenie zelaza ogolnego\nZakres (0,020 - 3,5) mg/l\nMetoda spektrofotometryczna PN-73/C-04586/03","categories":["water"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,020 - 3,5) mg/l"}],"search_en":"Water Total iron concentration Spectrophotometric method Range PN-73/C-04586/03","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 - 3,5) mg/l"}],"search_zh":"水 总铁浓度 分光光度法 范围 PN-73/C-04586/03","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f757","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(0,020 - 0,6) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie manganu\nZakres (0,020 - 0,6) mg/l\nMetoda spektrofotometryczna","reference":"PB/UC/05 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8149","norm_bases":["PB/UC/05 wydanie 1 z 10.02.2004 r.","na podstawie testu Hach nr 8149"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie manganu\nZakres (0,020 - 0,6) mg/l\nMetoda spektrofotometryczna PB/UC/05 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8149 Woda Stezenie manganu\nZakres (0,020 - 0,6) mg/l\nMetoda spektrofotometryczna PB/UC/05 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8149","categories":["water"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(0,020 - 0,6) mg/l"}],"search_en":"Water Manganese concentration Spectrophotometric method Range PB/UC/05 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8149","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(0,020 - 0,6) mg/l"}],"search_zh":"水 锰浓度 分光光度法 范围 PB/UC/05 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8149","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f758","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(10 - 500) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10 - 500) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (10 - 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (10 - 500) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(10 - 500) mg/l CaCO3"}],"search_en":"Water Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(10 - 500) mg/l CaCO3"}],"search_zh":"水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f759","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 250) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 250) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie chlorków\nZakres (5,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda Stezenie chlorkow\nZakres (5,0 – 250) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 250) mg/l"}],"search_en":"Water Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 250) mg/l"}],"search_zh":"水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f75a","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Zasadowość ogólna","parameters":[{"name":"Zakres","range":"(0,2 - 20) mval/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zasadowość ogólna\nZakres (0,2 - 20) mval/l\nMetoda miareczkowa","reference":"PN-EN ISO 9963-1:2001 + Ap1:2004","norm_bases":["PN-EN ISO 9963-1:2001 + Ap1:2004"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Zasadowość ogólna\nZakres (0,2 - 20) mval/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 + Ap1:2004 Woda Zasadowosc ogolna\nZakres (0,2 - 20) mval/l\nMetoda miareczkowa PN-EN ISO 9963-1:2001 + Ap1:2004","categories":["water"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total alkalinity","parameters_en":[{"name":"Range","range":"(0,2 - 20) mval/l"}],"search_en":"Water Total alkalinity Titrimetric method Range PN-EN ISO 9963-1:2001 + Ap1:2004","technique_en":"Titrimetric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,2 - 20) mval/l"}],"search_zh":"水 总碱度 滴定法 范围 PN-EN ISO 9963-1:2001 + Ap1:2004","technique_zh":"滴定法","test_object_zh":"水","methodology_zh":"总碱度"},{"_id":"6a83773faf14b9c0e7b1f75b","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie amoniaku (jonu amonowego)","parameters":[{"name":"Zakres","range":"(0,10 - 2,0) mg/l NH4+"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie amoniaku (jonu amonowego)\nZakres (0,10 - 2,0) mg/l NH4+\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie amoniaku (jonu amonowego)\nZakres (0,10 - 2,0) mg/l NH4+\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda Stezenie amoniaku (jonu amonowego)\nZakres (0,10 - 2,0) mg/l NH4+\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonia (ammonium ion) concentration","parameters_en":[{"name":"Range","range":"(0,10 - 2,0) mg/l NH4+"}],"search_en":"Water Ammonia (ammonium ion) concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,10 - 2,0) mg/l NH4+"}],"search_zh":"水 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f75c","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,002 - 0,800) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,002 - 0,800) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotynów\nZakres (0,002 - 0,800) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda Stezenie azotynow\nZakres (0,002 - 0,800) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,002 - 0,800) mg/l"}],"search_en":"Water Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,002 - 0,800) mg/l"}],"search_zh":"水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f75d","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)","parameters":[{"name":"Zakres","range":"(10,0 - 150) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (10,0 - 150) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (10,0 - 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Woda Chemiczne zapotrzebowanie tlenu (ChZT-Cr)\nZakres (10,0 - 150) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(10,0 - 150) mg/l O2"}],"search_en":"Water Chemical oxygen demand (COD-Cr) Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"化学需氧量（ChZT-Cr / CODCr）","parameters_zh":[{"name":"范围","range":"(10,0 - 150) mg/l O2"}],"search_zh":"水 化学需氧量（ChZT-Cr / CODCr） 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f75e","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"BZT5","parameters":[{"name":"Zakres","range":"(0,5 – 6,0) mg/l O2"}],"technique":"Metoda optyczna","techniques":["Metoda optyczna"],"computed":[],"activity":"BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna","reference":"PB/UC/51 wydanie 2 z 30.11.2012 r.","norm_bases":["PB/UC/51 wydanie 2 z 30.11.2012 r."],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna PB/UC/51 wydanie 2 z 30.11.2012 r. Woda BZT5\nZakres (0,5 – 6,0) mg/l O2\nMetoda optyczna PB/UC/51 wydanie 2 z 30.11.2012 r.","categories":["water"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"BOD5","parameters_en":[{"name":"Range","range":"(0,5 – 6,0) mg/l O2"}],"search_en":"Water BOD5 Optical method Range PB/UC/51 wydanie 2 z 30.11.2012 r.","technique_en":"Optical method","test_object_en":"Water","methodology_zh":"BZT5（BOD5）","parameters_zh":[{"name":"范围","range":"(0,5 – 6,0) mg/l O2"}],"search_zh":"水 BZT5（BOD5） 光学法 范围 PB/UC/51 wydanie 2 z 30.11.2012 r.","technique_zh":"光学法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f75f","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,050 - 1,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,050 - 1,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie ortofosforanów\nZakres (0,050 - 1,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010 Woda Stezenie ortofosforanow\nZakres (0,050 - 1,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,050 - 1,00) mg/l"}],"search_en":"Water Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water","parameters_zh":[{"name":"范围","range":"(0,050 - 1,00) mg/l"}],"search_zh":"水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a83773faf14b9c0e7b1f760","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 - 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 - 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 7 +Ap1:2010 +Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 7 +Ap1:2010 +Ap2:2010"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie fosforu ogólnego\nZakres (0,10 - 2,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7 +Ap1:2010 +Ap2:2010 Woda Stezenie fosforu ogolnego\nZakres (0,10 - 2,00) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 7 +Ap1:2010 +Ap2:2010","categories":["water"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10 - 2,00) mg/l"}],"search_en":"Water Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 7 +Ap1:2010 +Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 2,00) mg/l"}],"search_zh":"水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 7 +Ap1:2010 +Ap2:2010","technique_zh":"分光光度法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f761","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(5,0 – 250) mg/l"}],"technique":"Metoda turbidymetryczna","techniques":["Metoda turbidymetryczna"],"computed":[],"activity":"Stężenie siarczanów\nZakres (5,0 – 250) mg/l\nMetoda turbidymetryczna","reference":"PB/UC/11 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8051","norm_bases":["PB/UC/11 wydanie 1 z 10.02.2004 r.","na podstawie testu Hach nr 8051"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie siarczanów\nZakres (5,0 – 250) mg/l\nMetoda turbidymetryczna PB/UC/11 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8051 Woda Stezenie siarczanow\nZakres (5,0 – 250) mg/l\nMetoda turbidymetryczna PB/UC/11 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8051","categories":["water"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(5,0 – 250) mg/l"}],"search_en":"Water Sulfate concentration Turbidimetric method Range PB/UC/11 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8051","technique_en":"Turbidimetric method","test_object_en":"Water","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 250) mg/l"}],"search_zh":"水 硫酸盐浓度 浊度法 范围 PB/UC/11 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8051","test_object_zh":"水","technique_zh":"浊度法"},{"_id":"6a83773faf14b9c0e7b1f762","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 - 500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 - 500) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Zawiesiny ogólne\nZakres (5,0 - 500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Woda Zawiesiny ogolne\nZakres (5,0 - 500) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 - 500) mg/l"}],"search_en":"Water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 - 500) mg/l"}],"search_zh":"水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f763","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalniach) pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 - 10,0)"}],"search_en":"Water (including swimming pool water) pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 - 10,0)"}],"search_zh":"水（含游泳池水） pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水（含游泳池水）"},{"_id":"6a83773faf14b9c0e7b1f764","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 - 400) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 - 400) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Mętność\nZakres (0,10 - 400) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym woda na plywalniach) Metnosc\nZakres (0,10 - 400) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 - 400) NTU"}],"search_en":"Water (including swimming pool water) Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 - 400) NTU"}],"search_zh":"水（含游泳池水） 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）"},{"_id":"6a83773faf14b9c0e7b1f765","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 - 50) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 - 50) mg/l O2\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Indeks nadmanganianowy\nZakres (0,50 - 50) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalniach) Indeks nadmanganianowy\nZakres (0,50 - 50) mg/l O2\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 - 50) mg/l O2"}],"search_en":"Water (including swimming pool water) Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 - 50) mg/l O2"}],"search_zh":"水（含游泳池水） 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）"},{"_id":"6a83773faf14b9c0e7b1f766","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(3,0 - 60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (3,0 - 60) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Stężenie azotanów\nZakres (3,0 - 60) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Woda (w tym woda na plywalniach) Stezenie azotanow\nZakres (3,0 - 60) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(3,0 - 60) mg/l"}],"search_en":"Water (including swimming pool water) Nitrate concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(3,0 - 60) mg/l"}],"search_zh":"水（含游泳池水） 硝酸盐浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a83773faf14b9c0e7b1f767","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Stężenie chloru wolnego","parameters":[{"name":"Zakres","range":"(0,05 - 2,00) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru wolnego\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna","reference":"PB/UC/25 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8021","norm_bases":["PB/UC/25 wydanie 1 z 10.02.2004 r.","na podstawie testu Hach nr 8021"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Stężenie chloru wolnego\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna PB/UC/25 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8021 Woda (w tym woda na plywalniach) Stezenie chloru wolnego\nZakres (0,05 - 2,00) mg/l\nMetoda spektrofotometryczna PB/UC/25 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8021","categories":["water"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Free chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 - 2,00) mg/l"}],"search_en":"Water (including swimming pool water) Free chlorine concentration Spectrophotometric method Range PB/UC/25 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8021","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"游离氯浓度","parameters_zh":[{"name":"范围","range":"(0,05 - 2,00) mg/l"}],"search_zh":"水（含游泳池水） 游离氯浓度 分光光度法 范围 PB/UC/25 wydanie 1 z 10.02.2004 r. | na podstawie testu Hach nr 8021","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a83773faf14b9c0e7b1f768","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Stężenie chloru ogólnego","parameters":[{"name":"Zakres","range":"(0,05 – 2,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chloru ogólnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna","reference":"PB/UC/57 wyd. 1 z 01.12.2016","norm_bases":["PB/UC/57 wyd. 1 z 01.12.2016"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Stężenie chloru ogólnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PB/UC/57 wyd. 1 z 01.12.2016 Woda (w tym woda na plywalniach) Stezenie chloru ogolnego\nZakres (0,05 – 2,0) mg/l\nMetoda spektrofotometryczna PB/UC/57 wyd. 1 z 01.12.2016","categories":["water"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total chlorine concentration","parameters_en":[{"name":"Range","range":"(0,05 – 2,0) mg/l"}],"search_en":"Water (including swimming pool water) Total chlorine concentration Spectrophotometric method Range PB/UC/57 wyd. 1 z 01.12.2016","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"范围","range":"(0,05 – 2,0) mg/l"}],"search_zh":"水（含游泳池水） 总氯浓度 分光光度法 范围 PB/UC/57 wyd. 1 z 01.12.2016","technique_zh":"分光光度法","methodology_zh":"总氯浓度","test_object_zh":"水（含游泳池水）"},{"_id":"6a83773faf14b9c0e7b1f769","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Stężenie chloru związanego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie chloru związanego (z obliczeń)","reference":"PB/UC/57 wyd. 1 z 01.12.2016","norm_bases":["PB/UC/57 wyd. 1 z 01.12.2016"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Stężenie chloru związanego (z obliczeń) PB/UC/57 wyd. 1 z 01.12.2016 Woda (w tym woda na plywalniach) Stezenie chloru zwiazanego (z obliczen) PB/UC/57 wyd. 1 z 01.12.2016","categories":["water"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Combined chlorine concentration (calculated)","search_en":"Water (including swimming pool water) Combined chlorine concentration (calculated) PB/UC/57 wyd. 1 z 01.12.2016","test_object_en":"Water (including swimming pool water)","methodology_zh":"化合氯浓度（计算值）","search_zh":"水（含游泳池水） 化合氯浓度（计算值） PB/UC/57 wyd. 1 z 01.12.2016","test_object_zh":"水（含游泳池水）"},{"_id":"6a83773faf14b9c0e7b1f76a","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), ścieki","methodology":"Stężenie lotnych chlorowcowych pochodnych węglowodorów:","parameters":[{"name":"Zakres"},{"name":"trichlorometan (chloroform)","range":"(1,0 - 200) μg/l"},{"name":"bromodichlorometan","range":"(1,0 - 100) μg/l"},{"name":"dibromochlorometan","range":"(1,0 - 100) μg/l"},{"name":"tribromometan (bromoform)","range":"(1,0 - 100) μg/l"}],"technique":"Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie lotnych chlorowcowych pochodnych węglowodorów:\nZakres:\nZakres\ntrichlorometan (chloroform) (1,0 - 200) μg/l\nbromodichlorometan (1,0 - 100) μg/l\ndibromochlorometan (1,0 - 100) μg/l\ntribromometan (bromoform) (1,0 - 100) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002","norm_bases":["PN-EN ISO 10301:2002"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), ścieki Stężenie lotnych chlorowcowych pochodnych węglowodorów:\nZakres:\nZakres\ntrichlorometan (chloroform) (1,0 - 200) μg/l\nbromodichlorometan (1,0 - 100) μg/l\ndibromochlorometan (1,0 - 100) μg/l\ntribromometan (bromoform) (1,0 - 100) μg/l\nMetoda chromatografii gazowej z analizą fazy nadpowierzchniowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 Woda (w tym woda na plywalniach), scieki Stezenie lotnych chlorowcowych pochodnych weglowodorow:\nZakres:\nZakres\ntrichlorometan (chloroform) (1,0 - 200) μg/l\nbromodichlorometan (1,0 - 100) μg/l\ndibromochlorometan (1,0 - 100) μg/l\ntribromometan (bromoform) (1,0 - 100) μg/l\nMetoda chromatografii gazowej z analiza fazy nadpowierzchniowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002","categories":["water"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of volatile halogenated hydrocarbon derivatives:","parameters_en":[{"name":"Range"},{"name":"trichloromethane (chloroform)","range":"(1,0 - 200) μg/l"},{"name":"bromodichloromethane","range":"(1,0 - 100) μg/l"},{"name":"dibromochloromethane","range":"(1,0 - 100) μg/l"},{"name":"tribromomethane (bromoform)","range":"(1,0 - 100) μg/l"}],"search_en":"Water (including swimming pool water), wastewater Concentration of volatile halogenated hydrocarbon derivatives: Gas chromatography with headspace analysis with electron capture detection (GC-ECD) Range trichloromethane (chloroform) bromodichloromethane dibromochloromethane tribromomethane (bromoform) PN-EN ISO 10301:2002","technique_en":"Gas chromatography with headspace analysis with electron capture detection (GC-ECD)","test_object_en":"Water (including swimming pool water), wastewater","parameters_zh":[{"name":"范围"},{"name":"三氯甲烷（氯仿）","range":"(1,0 - 200) μg/l"},{"name":"一溴二氯甲烷","range":"(1,0 - 100) μg/l"},{"name":"二溴一氯甲烷","range":"(1,0 - 100) μg/l"},{"name":"三溴甲烷（溴仿）","range":"(1,0 - 100) μg/l"}],"search_zh":"水（含游泳池水）、废水 范围 三氯甲烷（氯仿） 一溴二氯甲烷 二溴一氯甲烷 三溴甲烷（溴仿） PN-EN ISO 10301:2002","test_object_zh":"水（含游泳池水）、废水"},{"_id":"6a83773faf14b9c0e7b1f76b","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach), ścieki","methodology":"Stężenie sumy THM (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie sumy THM (z obliczeń)","reference":"","norm_bases":[],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Fizyko-Chemiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach), ścieki Stężenie sumy THM (z obliczeń) Woda (w tym woda na plywalniach), scieki Stezenie sumy THM (z obliczen)","categories":["water"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of total THM (calculated)","search_en":"Water (including swimming pool water), wastewater Concentration of total THM (calculated)","test_object_en":"Water (including swimming pool water), wastewater","search_zh":"水（含游泳池水）、废水","test_object_zh":"水（含游泳池水）、废水"},{"_id":"6a83773faf14b9c0e7b1f76c","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w temp. 22°C","parameters":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w temp. 22°C\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda Ogolna liczba mikroorganizmow w temp. 22°C\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 22°C","search_en":"Water Total viable count at 22°C Plate method, pour plate PN-EN ISO 6222:2004","technique_en":"Plate method, pour plate","test_object_en":"Water","methodology_zh":"22°C 微生物总数","search_zh":"水 22°C 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","test_object_zh":"水","technique_zh":"平板法，倾注平板"},{"_id":"6a83773faf14b9c0e7b1f76d","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Ogólna liczba mikroorganizmów w temp. 30°C","parameters":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 30°C\nMetoda płytkowa, posiew wgłębny","reference":"PB/UC/50 wydanie 1 z 16.08.2012 r.","norm_bases":["PB/UC/50 wydanie 1 z 16.08.2012 r."],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Ogólna liczba mikroorganizmów w temp. 30°C\nMetoda płytkowa, posiew wgłębny PB/UC/50 wydanie 1 z 16.08.2012 r. Woda Ogolna liczba mikroorganizmow w temp. 30°C\nMetoda plytkowa, posiew wglebny PB/UC/50 wydanie 1 z 16.08.2012 r.","categories":["water"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total count of microorganisms at 30°C","search_en":"Water Total count of microorganisms at 30°C Plate method, pour plate PB/UC/50 wydanie 1 z 16.08.2012 r.","technique_en":"Plate method, pour plate","test_object_en":"Water","search_zh":"水 平板法，倾注平板 PB/UC/50 wydanie 1 z 16.08.2012 r.","test_object_zh":"水","technique_zh":"平板法，倾注平板"},{"_id":"6a83773faf14b9c0e7b1f76e","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"大肠菌群计数","search_zh":"水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f76f","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL (Colilert-18)","techniques":["Metoda NPL (Colilert-18)"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda NPL (Colilert-18)","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba bakterii grupy coli\nMetoda NPL (Colilert-18) PN-EN ISO 9308-2:2014-06 Woda Liczba bakterii grupy coli\nMetoda NPL (Colilert-18) PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water Coliform bacteria count MPN method (Colilert-18) PN-EN ISO 9308-2:2014-06","technique_en":"MPN method (Colilert-18)","test_object_en":"Water","methodology_zh":"大肠菌群计数","search_zh":"水 大肠菌群计数 MPN 法（Colilert-18） PN-EN ISO 9308-2:2014-06","test_object_zh":"水","technique_zh":"MPN 法（Colilert-18）"},{"_id":"6a83773faf14b9c0e7b1f770","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water","methodology_zh":"粪肠球菌计数","search_zh":"水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f771","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia)\nMetoda filtracji membranowej","reference":"PN-EN 26461-2:2001","norm_bases":["PN-EN 26461-2:2001"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba przetrwalników beztlenowców redukujących siarczyny (Clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001 Woda Liczba przetrwalnikow beztlenowcow redukujacych siarczyny (Clostridia)\nMetoda filtracji membranowej PN-EN 26461-2:2001","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of spores of sulphite-reducing anaerobes (Clostridia)","search_en":"Water Count of spores of sulphite-reducing anaerobes (Clostridia) Membrane filtration method PN-EN 26461-2:2001","technique_en":"Membrane filtration method","test_object_en":"Water","search_zh":"水 亚硫酸盐还原厌氧菌（梭菌属）芽孢数 膜过滤法 PN-EN 26461-2:2001","technique_zh":"膜过滤法","test_object_zh":"水","methodology_zh":"亚硫酸盐还原厌氧菌（梭菌属）芽孢数"},{"_id":"6a83773faf14b9c0e7b1f772","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Liczba Clostridium perfringens łącznie z przetrwalnikami","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016","norm_bases":["PN-EN ISO 14189:2016"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Liczba Clostridium perfringens łącznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016 Woda Liczba Clostridium perfringens lacznie z przetrwalnikami\nMetoda filtracji membranowej PN-EN ISO 14189:2016","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Clostridium perfringens count including spores","search_en":"Water Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189:2016","technique_en":"Membrane filtration method","test_object_en":"Water","search_zh":"水 产气荚膜梭菌数（含芽孢） 膜过滤法 PN-EN ISO 14189:2016","technique_zh":"膜过滤法","test_object_zh":"水","methodology_zh":"产气荚膜梭菌数（含芽孢）"},{"_id":"6a83773faf14b9c0e7b1f773","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym woda na plywalniach) Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water) Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水） 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a83773faf14b9c0e7b1f774","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym woda na plywalniach) Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water (including swimming pool water) Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水（含游泳池水） 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a83773faf14b9c0e7b1f775","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda NPL (Colilert-18)","techniques":["Metoda NPL (Colilert-18)"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda NPL (Colilert-18)","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Liczba Escherichia coli\nMetoda NPL (Colilert-18) PN-EN ISO 9308-2:2014-06 Woda (w tym woda na plywalniach) Liczba Escherichia coli\nMetoda NPL (Colilert-18) PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water (including swimming pool water) Escherichia coli count MPN method (Colilert-18) PN-EN ISO 9308-2:2014-06","technique_en":"MPN method (Colilert-18)","test_object_en":"Water (including swimming pool water)","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水（含游泳池水） 大肠埃希氏菌（Escherichia coli）计数 MPN 法（Colilert-18） PN-EN ISO 9308-2:2014-06","test_object_zh":"水（含游泳池水）","technique_zh":"MPN 法（Colilert-18）"},{"_id":"6a83773faf14b9c0e7b1f776","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Liczba bakterii z rodzaju Legionella","parameters":[{"name":"Zakres","range":"od 1 jtk/100 ml"},{"name":"Zakres","range":"od 1 jtk/1000 ml"},{"name":"Matryca A; Procedura 5, pożywka A (BCYE) Procedura 6 i 7 pożywka B (BCYE+AB) lub C (GVPC lub MWY)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella\nZakres:\nZakres od 1 jtk/100 ml\nZakres od 1 jtk/1000 ml\nMatryca A; Procedura 5, pożywka A (BCYE) Procedura 6 i 7 pożywka B (BCYE+AB) lub C (GVPC lub MWY)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08","norm_bases":["PN-EN ISO 11731:2017-08"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Liczba bakterii z rodzaju Legionella\nZakres:\nZakres od 1 jtk/100 ml\nZakres od 1 jtk/1000 ml\nMatryca A; Procedura 5, pożywka A (BCYE) Procedura 6 i 7 pożywka B (BCYE+AB) lub C (GVPC lub MWY)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 Woda (w tym woda na plywalniach) Liczba bakterii z rodzaju Legionella\nZakres:\nZakres od 1 jtk/100 ml\nZakres od 1 jtk/1000 ml\nMatryca A; Procedura 5, pozywka A (BCYE) Procedura 6 i 7 pozywka B (BCYE+AB) lub C (GVPC lub MWY)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08","categories":["microbiology","water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of bacteria of the genus Legionella","parameters_en":[{"name":"Range","range":"od 1 jtk/100 ml"},{"name":"Range","range":"od 1 jtk/1000 ml"},{"name":"Matryca A; Procedura 5, pożywka A (BCYE) Procedura 6 i 7 pożywka B (BCYE+AB) lub C (GVPC lub MWY)"}],"search_en":"Water (including swimming pool water) Count of bacteria of the genus Legionella Membrane filtration method Range Range PN-EN ISO 11731:2017-08","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"范围","range":"od 1 jtk/100 ml"},{"name":"范围","range":"od 1 jtk/1000 ml"},{"name":"Matryca A; Procedura 5, pożywka A (BCYE) Procedura 6 i 7 pożywka B (BCYE+AB) lub C (GVPC lub MWY)"}],"search_zh":"水（含游泳池水） 军团菌属细菌计数 膜过滤法 范围 范围 PN-EN ISO 11731:2017-08","technique_zh":"膜过滤法","methodology_zh":"军团菌属细菌计数","test_object_zh":"水（含游泳池水）"},{"_id":"6a83773faf14b9c0e7b1f777","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Liczba bakterii z rodzaju Legionella","parameters":[{"name":"Zakres","range":"od 10 jtk/1 ml"},{"name":"Zakres","range":"od 1000 jtk/100 ml"},{"name":"Zakres","range":"od 10000 jtk/1000 ml"},{"name":"Matryca A: Procedura 1 i 2, pożywka A (BCYE), B (BCYE+AB), C(GVPC lub MWY)"}],"technique":"Metoda płytkowa, posiew powierzchniowy","techniques":["Metoda płytkowa, posiew powierzchniowy"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella\nZakres:\nZakres od 10 jtk/1 ml\nZakres od 1000 jtk/100 ml\nZakres od 10000 jtk/1000 ml\nMatryca A: Procedura 1 i 2, pożywka A (BCYE), B (BCYE+AB), C(GVPC lub MWY)\nMetoda płytkowa, posiew powierzchniowy","reference":"PN-EN ISO 11731:2017-08","norm_bases":["PN-EN ISO 11731:2017-08"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Liczba bakterii z rodzaju Legionella\nZakres:\nZakres od 10 jtk/1 ml\nZakres od 1000 jtk/100 ml\nZakres od 10000 jtk/1000 ml\nMatryca A: Procedura 1 i 2, pożywka A (BCYE), B (BCYE+AB), C(GVPC lub MWY)\nMetoda płytkowa, posiew powierzchniowy PN-EN ISO 11731:2017-08 Woda (w tym woda na plywalniach) Liczba bakterii z rodzaju Legionella\nZakres:\nZakres od 10 jtk/1 ml\nZakres od 1000 jtk/100 ml\nZakres od 10000 jtk/1000 ml\nMatryca A: Procedura 1 i 2, pozywka A (BCYE), B (BCYE+AB), C(GVPC lub MWY)\nMetoda plytkowa, posiew powierzchniowy PN-EN ISO 11731:2017-08","categories":["microbiology","water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of bacteria of the genus Legionella","parameters_en":[{"name":"Range","range":"od 10 jtk/1 ml"},{"name":"Range","range":"od 1000 jtk/100 ml"},{"name":"Range","range":"od 10000 jtk/1000 ml"},{"name":"Matryca A: Procedura 1 i 2, pożywka A (BCYE), B (BCYE+AB), C(GVPC lub MWY)"}],"search_en":"Water (including swimming pool water) Count of bacteria of the genus Legionella Plate method, spread plate Range Range Range PN-EN ISO 11731:2017-08","technique_en":"Plate method, spread plate","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"范围","range":"od 10 jtk/1 ml"},{"name":"范围","range":"od 1000 jtk/100 ml"},{"name":"范围","range":"od 10000 jtk/1000 ml"},{"name":"Matryca A: Procedura 1 i 2, pożywka A (BCYE), B (BCYE+AB), C(GVPC lub MWY)"}],"search_zh":"水（含游泳池水） 军团菌属细菌计数 平板法，表面涂布 范围 范围 范围 PN-EN ISO 11731:2017-08","methodology_zh":"军团菌属细菌计数","test_object_zh":"水（含游泳池水）","technique_zh":"平板法，表面涂布"},{"_id":"6a83773faf14b9c0e7b1f778","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda (w tym woda na pływalniach)","methodology":"Ogólna liczba mikroorganizmów w temp. 36°C","parameters":[],"technique":"Metoda płytkowa, posiew wgłębny","techniques":["Metoda płytkowa, posiew wgłębny"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa, posiew wgłębny","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalniach) Ogólna liczba mikroorganizmów w temp. 36°C\nMetoda płytkowa, posiew wgłębny PN-EN ISO 6222:2004 Woda (w tym woda na plywalniach) Ogolna liczba mikroorganizmow w temp. 36°C\nMetoda plytkowa, posiew wglebny PN-EN ISO 6222:2004","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total viable count at 36°C","search_en":"Water (including swimming pool water) Total viable count at 36°C Plate method, pour plate PN-EN ISO 6222:2004","technique_en":"Plate method, pour plate","test_object_en":"Water (including swimming pool water)","search_zh":"水（含游泳池水） 36°C 微生物总数 平板法，倾注平板 PN-EN ISO 6222:2004","technique_zh":"平板法，倾注平板","test_object_zh":"水（含游泳池水）","methodology_zh":"36°C 微生物总数"},{"_id":"6a83773faf14b9c0e7b1f779","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba gronkowców koagulazododatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"PB/UC/46 wydanie 1 z 30.12.2010 r.","norm_bases":["PB/UC/46 wydanie 1 z 30.12.2010 r."],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Wody; Pracownia Mikrobiologiczna","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej PB/UC/46 wydanie 1 z 30.12.2010 r. Woda na plywalniach Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej PB/UC/46 wydanie 1 z 30.12.2010 r.","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count","search_en":"Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PB/UC/46 wydanie 1 z 30.12.2010 r.","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","search_zh":"游泳池水 凝固酶阳性葡萄球菌计数 膜过滤法 PB/UC/46 wydanie 1 z 30.12.2010 r.","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"凝固酶阳性葡萄球菌计数"},{"_id":"6a83773faf14b9c0e7b1f77a","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna; Metoda automatyczna","techniques":["Metoda manualna","Metoda automatyczna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11 Scieki Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna; Metoda automatyczna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Wastewater Sampling for chemical and physical testing Manual method; Automatic method PN-ISO 5667-10:2021-11","technique_en":"Manual method; Automatic method","test_object_en":"Wastewater","methodology_zh":"化学与物理检测用样品采集","search_zh":"污水 化学与物理检测用样品采集 手动法；自动法 PN-ISO 5667-10:2021-11","technique_zh":"手动法；自动法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f77b","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Temperatura","parameters":[{"name":"Zakres","range":"(1,0 – 50)°C"}],"technique":null,"techniques":[],"computed":[],"activity":"Temperatura\nZakres (1,0 – 50)°C","reference":"PB/RLS/24 wydanie 1 z 05.01.2012 r.","norm_bases":["PB/RLS/24 wydanie 1 z 05.01.2012 r."],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Temperatura\nZakres (1,0 – 50)°C PB/RLS/24 wydanie 1 z 05.01.2012 r. Scieki Temperatura\nZakres (1,0 – 50)°C PB/RLS/24 wydanie 1 z 05.01.2012 r.","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Temperature","parameters_en":[{"name":"Range","range":"(1,0 – 50)°C"}],"search_en":"Wastewater Temperature Range PB/RLS/24 wydanie 1 z 05.01.2012 r.","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1,0 – 50)°C"}],"search_zh":"污水 温度 范围 PB/RLS/24 wydanie 1 z 05.01.2012 r.","test_object_zh":"污水","methodology_zh":"温度"},{"_id":"6a83773faf14b9c0e7b1f77c","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"pH","parameters":[{"name":"Zakres","range":"(1,0 - 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (1,0 - 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki pH\nZakres (1,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Scieki pH\nZakres (1,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(1,0 - 12,0)"}],"search_en":"Wastewater pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Wastewater","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(1,0 - 12,0)"}],"search_zh":"污水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f77d","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,40 - 200) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,40 - 200) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu Kjeldahla\nZakres (0,40 - 200) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Scieki Stezenie azotu Kjeldahla\nZakres (0,40 - 200) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,40 - 200) mg/l"}],"search_en":"Wastewater Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,40 - 200) mg/l"}],"search_zh":"污水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f77e","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotanowego","parameters":[{"name":"Zakres","range":"(0,14 - 30,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotanowego\nZakres (0,14 - 30,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-82/C-04576.08","norm_bases":["PN-82/C-04576.08"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotanowego\nZakres (0,14 - 30,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08 Scieki Stezenie azotu azotanowego\nZakres (0,14 - 30,0) mg/l\nMetoda spektrofotometryczna PN-82/C-04576.08","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,14 - 30,0) mg/l"}],"search_en":"Wastewater Nitrate nitrogen concentration Spectrophotometric method Range PN-82/C-04576.08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,14 - 30,0) mg/l"}],"search_zh":"污水 硝态氮浓度 分光光度法 范围 PN-82/C-04576.08","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f77f","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu azotynowego","parameters":[{"name":"Zakres","range":"(0,03 - 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu azotynowego\nZakres (0,03 - 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu azotynowego\nZakres (0,03 - 5,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Scieki Stezenie azotu azotynowego\nZakres (0,03 - 5,0) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,03 - 5,0) mg/l"}],"search_en":"Wastewater Nitrite nitrogen concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"亚硝态氮浓度","parameters_zh":[{"name":"范围","range":"(0,03 - 5,0) mg/l"}],"search_zh":"污水 亚硝态氮浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f780","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu ogólnego (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie azotu ogólnego (z obliczeń)","reference":"PB/RLS/14 wydanie 2 z 31.01.2012 r.","norm_bases":["PB/RLS/14 wydanie 2 z 31.01.2012 r."],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu ogólnego (z obliczeń) PB/RLS/14 wydanie 2 z 31.01.2012 r. Scieki Stezenie azotu ogolnego (z obliczen) PB/RLS/14 wydanie 2 z 31.01.2012 r.","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total nitrogen concentration (calculated)","search_en":"Wastewater Total nitrogen concentration (calculated) PB/RLS/14 wydanie 2 z 31.01.2012 r.","test_object_en":"Wastewater","methodology_zh":"总氮浓度（计算值）","search_zh":"污水 总氮浓度（计算值） PB/RLS/14 wydanie 2 z 31.01.2012 r.","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f781","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT- Cr)","parameters":[{"name":"Zakres","range":"(10 - 7 000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT- Cr)\nZakres (10 - 7 000) mg/l O2\nMetoda miareczkowa","reference":"PB/RLS/21 wydanie 2 z dnia 27.11.2012 r.","norm_bases":["PB/RLS/21 wydanie 2 z dnia 27.11.2012 r."],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu (ChZT- Cr)\nZakres (10 - 7 000) mg/l O2\nMetoda miareczkowa PB/RLS/21 wydanie 2 z dnia 27.11.2012 r. Scieki Chemiczne zapotrzebowanie tlenu (ChZT- Cr)\nZakres (10 - 7 000) mg/l O2\nMetoda miareczkowa PB/RLS/21 wydanie 2 z dnia 27.11.2012 r.","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(10 - 7 000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand (COD-Cr) Titrimetric method Range PB/RLS/21 wydanie 2 z dnia 27.11.2012 r.","technique_en":"Titrimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10 - 7 000) mg/l O2"}],"search_zh":"污水 滴定法 范围 PB/RLS/21 wydanie 2 z dnia 27.11.2012 r.","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f782","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT- Cr)","parameters":[{"name":"Zakres","range":"(30 - 50 000) mg/l O2"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT- Cr)\nZakres (30 - 50 000) mg/l O2\nMetoda miareczkowa","reference":"PN-ISO 6060:2006","norm_bases":["PN-ISO 6060:2006"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu (ChZT- Cr)\nZakres (30 - 50 000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006 Scieki Chemiczne zapotrzebowanie tlenu (ChZT- Cr)\nZakres (30 - 50 000) mg/l O2\nMetoda miareczkowa PN-ISO 6060:2006","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(30 - 50 000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand (COD-Cr) Titrimetric method Range PN-ISO 6060:2006","technique_en":"Titrimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(30 - 50 000) mg/l O2"}],"search_zh":"污水 滴定法 范围 PN-ISO 6060:2006","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f783","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Chemiczne zapotrzebowanie tlenu (ChZT- Cr)","parameters":[{"name":"Zakres","range":"(10,0 - 1000) mg/l O2"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Chemiczne zapotrzebowanie tlenu (ChZT- Cr)\nZakres (10,0 - 1000) mg/l O2\nMetoda spektrofotometryczna","reference":"PN-ISO 15705:2005","norm_bases":["PN-ISO 15705:2005"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Chemiczne zapotrzebowanie tlenu (ChZT- Cr)\nZakres (10,0 - 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005 Scieki Chemiczne zapotrzebowanie tlenu (ChZT- Cr)\nZakres (10,0 - 1000) mg/l O2\nMetoda spektrofotometryczna PN-ISO 15705:2005","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chemical oxygen demand (COD-Cr)","parameters_en":[{"name":"Range","range":"(10,0 - 1000) mg/l O2"}],"search_en":"Wastewater Chemical oxygen demand (COD-Cr) Spectrophotometric method Range PN-ISO 15705:2005","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10,0 - 1000) mg/l O2"}],"search_zh":"污水 分光光度法 范围 PN-ISO 15705:2005","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f784","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 – 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Zawiesiny ogólne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Scieki Zawiesiny ogolne\nZakres (5,0 – 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 – 2000) mg/l"}],"search_en":"Wastewater Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 – 2000) mg/l"}],"search_zh":"污水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f785","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Substancje ekstrahujące się eterem naftowym","parameters":[{"name":"Zakres","range":"(10 - 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Substancje ekstrahujące się eterem naftowym\nZakres (10 - 2000) mg/l\nMetoda wagowa","reference":"PB/RLS/13 wydanie 2 z 20.01.2012 r.","norm_bases":["PB/RLS/13 wydanie 2 z 20.01.2012 r."],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Substancje ekstrahujące się eterem naftowym\nZakres (10 - 2000) mg/l\nMetoda wagowa PB/RLS/13 wydanie 2 z 20.01.2012 r. Scieki Substancje ekstrahujace sie eterem naftowym\nZakres (10 - 2000) mg/l\nMetoda wagowa PB/RLS/13 wydanie 2 z 20.01.2012 r.","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Substances extractable with petroleum ether","parameters_en":[{"name":"Range","range":"(10 - 2000) mg/l"}],"search_en":"Wastewater Substances extractable with petroleum ether Gravimetric method Range PB/RLS/13 wydanie 2 z 20.01.2012 r.","technique_en":"Gravimetric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(10 - 2000) mg/l"}],"search_zh":"污水 石油醚可萃取物 重量法 范围 PB/RLS/13 wydanie 2 z 20.01.2012 r.","technique_zh":"重量法","test_object_zh":"污水","methodology_zh":"石油醚可萃取物"},{"_id":"6a83773faf14b9c0e7b1f786","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Surfaktanty anionowe (Detergenty anionowe)","parameters":[{"name":"Zakres","range":"(0,2 – 20) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Surfaktanty anionowe (Detergenty anionowe)\nZakres (0,2 – 20) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 903:2002","norm_bases":["PN-EN 903:2002"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Surfaktanty anionowe (Detergenty anionowe)\nZakres (0,2 – 20) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002 Scieki Surfaktanty anionowe (Detergenty anionowe)\nZakres (0,2 – 20) mg/l\nMetoda spektrofotometryczna PN-EN 903:2002","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anionic surfactants (Anionic detergents)","parameters_en":[{"name":"Range","range":"(0,2 – 20) mg/l"}],"search_en":"Wastewater Anionic surfactants (Anionic detergents) Spectrophotometric method Range PN-EN 903:2002","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,2 – 20) mg/l"}],"search_zh":"污水 分光光度法 范围 PN-EN 903:2002","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f787","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie fosforu ogólnego","parameters":[{"name":"Zakres","range":"(0,10 - 50,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie fosforu ogólnego\nZakres (0,10 - 50,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie fosforu ogólnego\nZakres (0,10 - 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010 Scieki Stezenie fosforu ogolnego\nZakres (0,10 - 50,0) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus concentration","parameters_en":[{"name":"Range","range":"(0,10 - 50,0) mg/l"}],"search_en":"Wastewater Total phosphorus concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","methodology_zh":"总磷浓度","parameters_zh":[{"name":"范围","range":"(0,10 - 50,0) mg/l"}],"search_zh":"污水 总磷浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt 8 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f788","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(1,0 - 1000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (1,0 - 1000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 5664:2002","norm_bases":["PN-ISO 5664:2002"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie azotu amonowego\nZakres (1,0 - 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002 Scieki Stezenie azotu amonowego\nZakres (1,0 - 1000) mg/l\nMetoda miareczkowa PN-ISO 5664:2002","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(1,0 - 1000) mg/l"}],"search_en":"Wastewater Ammonium nitrogen concentration Titrimetric method Range PN-ISO 5664:2002","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(1,0 - 1000) mg/l"}],"search_zh":"污水 氨氮浓度 滴定法 范围 PN-ISO 5664:2002","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f789","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie siarczanów","parameters":[{"name":"Zakres","range":"(20 - 2500) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Stężenie siarczanów\nZakres (20 - 2500) mg/l\nMetoda wagowa","reference":"PN-ISO 9280:2002","norm_bases":["PN-ISO 9280:2002"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie siarczanów\nZakres (20 - 2500) mg/l\nMetoda wagowa PN-ISO 9280:2002 Scieki Stezenie siarczanow\nZakres (20 - 2500) mg/l\nMetoda wagowa PN-ISO 9280:2002","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfate concentration","parameters_en":[{"name":"Range","range":"(20 - 2500) mg/l"}],"search_en":"Wastewater Sulfate concentration Gravimetric method Range PN-ISO 9280:2002","technique_en":"Gravimetric method","test_object_en":"Wastewater","methodology_zh":"硫酸盐浓度","parameters_zh":[{"name":"范围","range":"(20 - 2500) mg/l"}],"search_zh":"污水 硫酸盐浓度 重量法 范围 PN-ISO 9280:2002","technique_zh":"重量法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f78a","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Indeks fenolowy","parameters":[{"name":"Zakres","range":"(0,005 - 0,5) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Indeks fenolowy\nZakres (0,005 - 0,5) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6439:1994 metoda B","norm_bases":["PN-ISO 6439:1994 metoda B"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Indeks fenolowy\nZakres (0,005 - 0,5) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B Scieki Indeks fenolowy\nZakres (0,005 - 0,5) mg/l\nMetoda spektrofotometryczna PN-ISO 6439:1994 metoda B","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Phenol index","parameters_en":[{"name":"Range","range":"(0,005 - 0,5) mg/l"}],"search_en":"Wastewater Phenol index Spectrophotometric method Range PN-ISO 6439:1994 metoda B","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,005 - 0,5) mg/l"}],"search_zh":"污水 酚指数 分光光度法 范围 PN-ISO 6439:1994 metoda B","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"酚指数"},{"_id":"6a83773faf14b9c0e7b1f78b","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Suma metali (Cr, Zn, Cd, Cu, Ni, Pb) (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Suma metali (Cr, Zn, Cd, Cu, Ni, Pb) (z obliczeń)","reference":"PB/RLS/26 wydanie 1 z 30.11.2012 r.","norm_bases":["PB/RLS/26 wydanie 1 z 30.11.2012 r."],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Suma metali (Cr, Zn, Cd, Cu, Ni, Pb) (z obliczeń) PB/RLS/26 wydanie 1 z 30.11.2012 r. Scieki Suma metali (Cr, Zn, Cd, Cu, Ni, Pb) (z obliczen) PB/RLS/26 wydanie 1 z 30.11.2012 r.","categories":["materials","water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sum of metals (Cr, Zn, Cd, Cu, Ni, Pb) (calculated)","search_en":"Wastewater Sum of metals (Cr, Zn, Cd, Cu, Ni, Pb) (calculated) PB/RLS/26 wydanie 1 z 30.11.2012 r.","test_object_en":"Wastewater","search_zh":"污水 PB/RLS/26 wydanie 1 z 30.11.2012 r.","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f78c","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"BZT5, BZT2+5","parameters":[{"name":"Zakres","range":"(1 – 2100) mg/l O2"}],"technique":"Metoda elektrochemiczna","techniques":["Metoda elektrochemiczna"],"computed":[],"activity":"BZT5, BZT2+5\nZakres (1 – 2100) mg/l O2\nMetoda elektrochemiczna","reference":"PN-EN ISO 5815-1:2019-12","norm_bases":["PN-EN ISO 5815-1:2019-12"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki BZT5, BZT2+5\nZakres (1 – 2100) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12 Scieki BZT5, BZT2+5\nZakres (1 – 2100) mg/l O2\nMetoda elektrochemiczna PN-EN ISO 5815-1:2019-12","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"BOD5, BOD2+5","parameters_en":[{"name":"Range","range":"(1 – 2100) mg/l O2"}],"search_en":"Wastewater BOD5, BOD2+5 Electrochemical method Range PN-EN ISO 5815-1:2019-12","technique_en":"Electrochemical method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(1 – 2100) mg/l O2"}],"search_zh":"污水 BOD5、BOD2+5 电化学法 范围 PN-EN ISO 5815-1:2019-12","technique_zh":"电化学法","test_object_zh":"污水","methodology_zh":"BOD5、BOD2+5"},{"_id":"6a83773faf14b9c0e7b1f78d","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 – 1500) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 – 1500) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chlorków\nZakres (5,0 – 1500) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Scieki Stezenie chlorkow\nZakres (5,0 – 1500) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 – 1500) mg/l"}],"search_en":"Wastewater Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Wastewater","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 – 1500) mg/l"}],"search_zh":"污水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"污水"},{"_id":"6a83773faf14b9c0e7b1f78e","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie chromu (VI)","parameters":[{"name":"Zakres","range":"(0,010 – 5,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie chromu (VI)\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-77/C-04604/08","norm_bases":["PN-77/C-04604/08"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie chromu (VI)\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08 Scieki Stezenie chromu (VI)\nZakres (0,010 – 5,0) mg/l\nMetoda spektrofotometryczna PN-77/C-04604/08","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chromium(VI) concentration","parameters_en":[{"name":"Range","range":"(0,010 – 5,0) mg/l"}],"search_en":"Wastewater Chromium(VI) concentration Spectrophotometric method Range PN-77/C-04604/08","technique_en":"Spectrophotometric method","test_object_en":"Wastewater","parameters_zh":[{"name":"范围","range":"(0,010 – 5,0) mg/l"}],"search_zh":"污水 六价铬浓度 分光光度法 范围 PN-77/C-04604/08","technique_zh":"分光光度法","test_object_zh":"污水","methodology_zh":"六价铬浓度"},{"_id":"6a83773faf14b9c0e7b1f78f","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali:","parameters":[{"name":"Zakres"},{"name":"Cd","range":"(0,001 - 100) mg/l"},{"name":"Pb","range":"(0,005 - 100) mg/l"},{"name":"Zn","range":"(0,020 - 100) mg/l"},{"name":"Cr","range":"(0,005 - 100) mg/l"},{"name":"Ni","range":"(0,002 - 100) mg/l"},{"name":"Cu","range":"(0,020 - 100) mg/l"},{"name":"Fe","range":"(0,020 - 10) mg/l"},{"name":"Mn","range":"(0,010 - 10) mg/l"},{"name":"Al","range":"(0,020 - 10) mg/l"},{"name":"Ca","range":"(1 - 300) mg/l"},{"name":"Mg","range":"(1 - 300) mg/l"},{"name":"Na","range":"(1 - 300) mg/l"},{"name":"K","range":"(1 - 300) mg/l"},{"name":"B","range":"(0,1 – 20) mg/l"},{"name":"Ba","range":"(0,010 – 20,0) mg/l"},{"name":"Be","range":"(0,020 – 5,0) mg/l"},{"name":"Co","range":"(0,010 – 5,0) mg/l"},{"name":"Ag","range":"(0,002 – 0,5) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali:\nZakres:\nZakres\nCd (0,001 - 100) mg/l\nPb (0,005 - 100) mg/l\nZn (0,020 - 100) mg/l\nCr (0,005 - 100) mg/l\nNi (0,002 - 100) mg/l\nCu (0,020 - 100) mg/l\nFe (0,020 - 10) mg/l\nMn (0,010 - 10) mg/l\nAl (0,020 - 10) mg/l\nCa (1 - 300) mg/l\nMg (1 - 300) mg/l\nNa (1 - 300) mg/l\nK (1 - 300) mg/l\nB (0,1 – 20) mg/l\nBa (0,010 – 20,0) mg/l\nBe (0,020 – 5,0) mg/l\nCo (0,010 – 5,0) mg/l\nAg (0,002 – 0,5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali:\nZakres:\nZakres\nCd (0,001 - 100) mg/l\nPb (0,005 - 100) mg/l\nZn (0,020 - 100) mg/l\nCr (0,005 - 100) mg/l\nNi (0,002 - 100) mg/l\nCu (0,020 - 100) mg/l\nFe (0,020 - 10) mg/l\nMn (0,010 - 10) mg/l\nAl (0,020 - 10) mg/l\nCa (1 - 300) mg/l\nMg (1 - 300) mg/l\nNa (1 - 300) mg/l\nK (1 - 300) mg/l\nB (0,1 – 20) mg/l\nBa (0,010 – 20,0) mg/l\nBe (0,020 – 5,0) mg/l\nCo (0,010 – 5,0) mg/l\nAg (0,002 – 0,5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie metali:\nZakres:\nZakres\nCd (0,001 - 100) mg/l\nPb (0,005 - 100) mg/l\nZn (0,020 - 100) mg/l\nCr (0,005 - 100) mg/l\nNi (0,002 - 100) mg/l\nCu (0,020 - 100) mg/l\nFe (0,020 - 10) mg/l\nMn (0,010 - 10) mg/l\nAl (0,020 - 10) mg/l\nCa (1 - 300) mg/l\nMg (1 - 300) mg/l\nNa (1 - 300) mg/l\nK (1 - 300) mg/l\nB (0,1 – 20) mg/l\nBa (0,010 – 20,0) mg/l\nBe (0,020 – 5,0) mg/l\nCo (0,010 – 5,0) mg/l\nAg (0,002 – 0,5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations:","parameters_en":[{"name":"Range"},{"name":"Cd","range":"(0,001 - 100) mg/l"},{"name":"Pb","range":"(0,005 - 100) mg/l"},{"name":"Zn","range":"(0,020 - 100) mg/l"},{"name":"Cr","range":"(0,005 - 100) mg/l"},{"name":"Ni","range":"(0,002 - 100) mg/l"},{"name":"Cu","range":"(0,020 - 100) mg/l"},{"name":"Fe","range":"(0,020 - 10) mg/l"},{"name":"Mn","range":"(0,010 - 10) mg/l"},{"name":"Al","range":"(0,020 - 10) mg/l"},{"name":"Ca","range":"(1 - 300) mg/l"},{"name":"Mg","range":"(1 - 300) mg/l"},{"name":"Na","range":"(1 - 300) mg/l"},{"name":"K","range":"(1 - 300) mg/l"},{"name":"B","range":"(0,1 – 20) mg/l"},{"name":"Ba","range":"(0,010 – 20,0) mg/l"},{"name":"Be","range":"(0,020 – 5,0) mg/l"},{"name":"Co","range":"(0,010 – 5,0) mg/l"},{"name":"Ag","range":"(0,002 – 0,5) mg/l"}],"search_en":"Wastewater Metal concentrations: Inductively coupled plasma optical emission spectrometry (ICP-OES) Range Cd Pb Zn Cr Ni Cu Fe Mn Al Ca Mg Na K B Ba Be Co Ag PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Wastewater","parameters_zh":[{"name":"范围"},{"name":"Cd","range":"(0,001 - 100) mg/l"},{"name":"Pb","range":"(0,005 - 100) mg/l"},{"name":"Zn","range":"(0,020 - 100) mg/l"},{"name":"Cr","range":"(0,005 - 100) mg/l"},{"name":"Ni","range":"(0,002 - 100) mg/l"},{"name":"Cu","range":"(0,020 - 100) mg/l"},{"name":"Fe","range":"(0,020 - 10) mg/l"},{"name":"Mn","range":"(0,010 - 10) mg/l"},{"name":"Al","range":"(0,020 - 10) mg/l"},{"name":"Ca","range":"(1 - 300) mg/l"},{"name":"Mg","range":"(1 - 300) mg/l"},{"name":"Na","range":"(1 - 300) mg/l"},{"name":"K","range":"(1 - 300) mg/l"},{"name":"B","range":"(0,1 – 20) mg/l"},{"name":"Ba","range":"(0,010 – 20,0) mg/l"},{"name":"Be","range":"(0,020 – 5,0) mg/l"},{"name":"Co","range":"(0,010 – 5,0) mg/l"},{"name":"Ag","range":"(0,002 – 0,5) mg/l"}],"search_zh":"污水 金属浓度： 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 Cd Pb Zn Cr Ni Cu Fe Mn Al Ca Mg Na K B Ba Be Co Ag PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污水","methodology_zh":"金属浓度："},{"_id":"6a83773faf14b9c0e7b1f790","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Ścieki","methodology":"Stężenie metali:","parameters":[{"name":"Zakres"},{"name":"Sb","range":"(0,001 – 0,5) mg/l"},{"name":"As","range":"(0,001 – 0,5) mg/l"},{"name":"Se","range":"(0,002 – 1,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Stężenie metali:\nZakres:\nZakres\nSb (0,001 – 0,5) mg/l\nAs (0,001 – 0,5) mg/l\nSe (0,002 – 1,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ścieki Stężenie metali:\nZakres:\nZakres\nSb (0,001 – 0,5) mg/l\nAs (0,001 – 0,5) mg/l\nSe (0,002 – 1,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 Scieki Stezenie metali:\nZakres:\nZakres\nSb (0,001 – 0,5) mg/l\nAs (0,001 – 0,5) mg/l\nSe (0,002 – 1,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations:","parameters_en":[{"name":"Range"},{"name":"Sb","range":"(0,001 – 0,5) mg/l"},{"name":"As","range":"(0,001 – 0,5) mg/l"},{"name":"Se","range":"(0,002 – 1,0) mg/l"}],"search_en":"Wastewater Metal concentrations: Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) Range Sb As Se PN-EN ISO 11885:2009","technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","test_object_en":"Wastewater","parameters_zh":[{"name":"范围"},{"name":"Sb","range":"(0,001 – 0,5) mg/l"},{"name":"As","range":"(0,001 – 0,5) mg/l"},{"name":"Se","range":"(0,002 – 1,0) mg/l"}],"search_zh":"污水 金属浓度： 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） 范围 Sb As Se PN-EN ISO 11885:2009","test_object_zh":"污水","technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）","methodology_zh":"金属浓度："},{"_id":"6a83773faf14b9c0e7b1f791","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie azotu Kjeldahla","parameters":[{"name":"Zakres","range":"(0,40 – 5,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie azotu Kjeldahla\nZakres (0,40 – 5,0) mg/l\nMetoda miareczkowa","reference":"PN-EN 25663:2001","norm_bases":["PN-EN 25663:2001"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie azotu Kjeldahla\nZakres (0,40 – 5,0) mg/l\nMetoda miareczkowa PN-EN 25663:2001 Woda Stezenie azotu Kjeldahla\nZakres (0,40 – 5,0) mg/l\nMetoda miareczkowa PN-EN 25663:2001","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Kjeldahl nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,40 – 5,0) mg/l"}],"search_en":"Water Kjeldahl nitrogen concentration Titrimetric method Range PN-EN 25663:2001","technique_en":"Titrimetric method","test_object_en":"Water","methodology_zh":"凯氏氮浓度","parameters_zh":[{"name":"范围","range":"(0,40 – 5,0) mg/l"}],"search_zh":"水 凯氏氮浓度 滴定法 范围 PN-EN 25663:2001","technique_zh":"滴定法","test_object_zh":"水"},{"_id":"6a83773faf14b9c0e7b1f792","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie metali:","parameters":[{"name":"Zakres"},{"name":"Cd","range":"(0,001 - 10) mg/l"},{"name":"Pb","range":"(0,005 - 10) mg/l"},{"name":"Zn","range":"(0,020 - 10) mg/l"},{"name":"Cr","range":"(0,005 - 10) mg/l"},{"name":"Ni","range":"(0,002 - 10) mg/l"},{"name":"Cu","range":"(0,020 - 10) mg/l"},{"name":"Fe","range":"(0,020 - 10) mg/l"},{"name":"Mn","range":"(0,010 - 10) mg/l"},{"name":"Al","range":"(0,020 - 10) mg/l"},{"name":"Ca","range":"(1 - 300) mg/l"},{"name":"Mg","range":"(1 - 300) mg/l"},{"name":"Na","range":"(1 - 300) mg/l"},{"name":"K","range":"(1 - 300) mg/l"},{"name":"B","range":"(0,1 – 5,0) mg/l"},{"name":"Ba","range":"(0,010 – 5,0) mg/l"},{"name":"Be","range":"(0,020 – 5,0) mg/l"},{"name":"Co","range":"(0,010 – 5,0) mg/l"},{"name":"Ag","range":"(0,002 – 0,5) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Stężenie metali:\nZakres:\nZakres\nCd (0,001 - 10) mg/l\nPb (0,005 - 10) mg/l\nZn (0,020 - 10) mg/l\nCr (0,005 - 10) mg/l\nNi (0,002 - 10) mg/l\nCu (0,020 - 10) mg/l\nFe (0,020 - 10) mg/l\nMn (0,010 - 10) mg/l\nAl (0,020 - 10) mg/l\nCa (1 - 300) mg/l\nMg (1 - 300) mg/l\nNa (1 - 300) mg/l\nK (1 - 300) mg/l\nB (0,1 – 5,0) mg/l\nBa (0,010 – 5,0) mg/l\nBe (0,020 – 5,0) mg/l\nCo (0,010 – 5,0) mg/l\nAg (0,002 – 0,5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie metali:\nZakres:\nZakres\nCd (0,001 - 10) mg/l\nPb (0,005 - 10) mg/l\nZn (0,020 - 10) mg/l\nCr (0,005 - 10) mg/l\nNi (0,002 - 10) mg/l\nCu (0,020 - 10) mg/l\nFe (0,020 - 10) mg/l\nMn (0,010 - 10) mg/l\nAl (0,020 - 10) mg/l\nCa (1 - 300) mg/l\nMg (1 - 300) mg/l\nNa (1 - 300) mg/l\nK (1 - 300) mg/l\nB (0,1 – 5,0) mg/l\nBa (0,010 – 5,0) mg/l\nBe (0,020 – 5,0) mg/l\nCo (0,010 – 5,0) mg/l\nAg (0,002 – 0,5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie metali:\nZakres:\nZakres\nCd (0,001 - 10) mg/l\nPb (0,005 - 10) mg/l\nZn (0,020 - 10) mg/l\nCr (0,005 - 10) mg/l\nNi (0,002 - 10) mg/l\nCu (0,020 - 10) mg/l\nFe (0,020 - 10) mg/l\nMn (0,010 - 10) mg/l\nAl (0,020 - 10) mg/l\nCa (1 - 300) mg/l\nMg (1 - 300) mg/l\nNa (1 - 300) mg/l\nK (1 - 300) mg/l\nB (0,1 – 5,0) mg/l\nBa (0,010 – 5,0) mg/l\nBe (0,020 – 5,0) mg/l\nCo (0,010 – 5,0) mg/l\nAg (0,002 – 0,5) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations:","parameters_en":[{"name":"Range"},{"name":"Cd","range":"(0,001 - 10) mg/l"},{"name":"Pb","range":"(0,005 - 10) mg/l"},{"name":"Zn","range":"(0,020 - 10) mg/l"},{"name":"Cr","range":"(0,005 - 10) mg/l"},{"name":"Ni","range":"(0,002 - 10) mg/l"},{"name":"Cu","range":"(0,020 - 10) mg/l"},{"name":"Fe","range":"(0,020 - 10) mg/l"},{"name":"Mn","range":"(0,010 - 10) mg/l"},{"name":"Al","range":"(0,020 - 10) mg/l"},{"name":"Ca","range":"(1 - 300) mg/l"},{"name":"Mg","range":"(1 - 300) mg/l"},{"name":"Na","range":"(1 - 300) mg/l"},{"name":"K","range":"(1 - 300) mg/l"},{"name":"B","range":"(0,1 – 5,0) mg/l"},{"name":"Ba","range":"(0,010 – 5,0) mg/l"},{"name":"Be","range":"(0,020 – 5,0) mg/l"},{"name":"Co","range":"(0,010 – 5,0) mg/l"},{"name":"Ag","range":"(0,002 – 0,5) mg/l"}],"search_en":"Water Metal concentrations: Inductively coupled plasma optical emission spectrometry (ICP-OES) Range Cd Pb Zn Cr Ni Cu Fe Mn Al Ca Mg Na K B Ba Be Co Ag PN-EN ISO 11885:2009","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Water","parameters_zh":[{"name":"范围"},{"name":"Cd","range":"(0,001 - 10) mg/l"},{"name":"Pb","range":"(0,005 - 10) mg/l"},{"name":"Zn","range":"(0,020 - 10) mg/l"},{"name":"Cr","range":"(0,005 - 10) mg/l"},{"name":"Ni","range":"(0,002 - 10) mg/l"},{"name":"Cu","range":"(0,020 - 10) mg/l"},{"name":"Fe","range":"(0,020 - 10) mg/l"},{"name":"Mn","range":"(0,010 - 10) mg/l"},{"name":"Al","range":"(0,020 - 10) mg/l"},{"name":"Ca","range":"(1 - 300) mg/l"},{"name":"Mg","range":"(1 - 300) mg/l"},{"name":"Na","range":"(1 - 300) mg/l"},{"name":"K","range":"(1 - 300) mg/l"},{"name":"B","range":"(0,1 – 5,0) mg/l"},{"name":"Ba","range":"(0,010 – 5,0) mg/l"},{"name":"Be","range":"(0,020 – 5,0) mg/l"},{"name":"Co","range":"(0,010 – 5,0) mg/l"},{"name":"Ag","range":"(0,002 – 0,5) mg/l"}],"search_zh":"水 金属浓度： 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 Cd Pb Zn Cr Ni Cu Fe Mn Al Ca Mg Na K B Ba Be Co Ag PN-EN ISO 11885:2009","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"水","methodology_zh":"金属浓度："},{"_id":"6a83773faf14b9c0e7b1f793","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda","methodology":"Stężenie metali:","parameters":[{"name":"Zakres"},{"name":"Sb","range":"(0,001 – 0,5) mg/l"},{"name":"As","range":"(0,001 – 0,5) mg/l"},{"name":"Se","range":"(0,002 – 1,0) mg/l"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)"],"computed":[],"activity":"Stężenie metali:\nZakres:\nZakres\nSb (0,001 – 0,5) mg/l\nAs (0,001 – 0,5) mg/l\nSe (0,002 – 1,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES)","reference":"PN-EN ISO 11885:2009","norm_bases":["PN-EN ISO 11885:2009"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda Stężenie metali:\nZakres:\nZakres\nSb (0,001 – 0,5) mg/l\nAs (0,001 – 0,5) mg/l\nSe (0,002 – 1,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej z generowaniem wodorków (HG-ICP-OES) PN-EN ISO 11885:2009 Woda Stezenie metali:\nZakres:\nZakres\nSb (0,001 – 0,5) mg/l\nAs (0,001 – 0,5) mg/l\nSe (0,002 – 1,0) mg/l\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej z generowaniem wodorkow (HG-ICP-OES) PN-EN ISO 11885:2009","categories":["materials","water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal concentrations:","parameters_en":[{"name":"Range"},{"name":"Sb","range":"(0,001 – 0,5) mg/l"},{"name":"As","range":"(0,001 – 0,5) mg/l"},{"name":"Se","range":"(0,002 – 1,0) mg/l"}],"search_en":"Water Metal concentrations: Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) Range Sb As Se PN-EN ISO 11885:2009","technique_en":"Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES)","test_object_en":"Water","parameters_zh":[{"name":"范围"},{"name":"Sb","range":"(0,001 – 0,5) mg/l"},{"name":"As","range":"(0,001 – 0,5) mg/l"},{"name":"Se","range":"(0,002 – 1,0) mg/l"}],"search_zh":"水 金属浓度： 氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES） 范围 Sb As Se PN-EN ISO 11885:2009","test_object_zh":"水","technique_zh":"氢化物发生电感耦合等离子体发射光谱法（HG-ICP-OES）","methodology_zh":"金属浓度："},{"_id":"6a83773faf14b9c0e7b1f794","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Woda, ścieki","methodology":"Stężenie rtęci","parameters":[{"name":"Zakres","range":"(0,0003 – 0,10) mg/l"}],"technique":"Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","techniques":["Metoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji"],"computed":[],"activity":"Stężenie rtęci\nZakres (0,0003 – 0,10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji","reference":"PB/RLS/25 wydanie 1 z 15.06.2012 r.","norm_bases":["PB/RLS/25 wydanie 1 z 15.06.2012 r."],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda, ścieki Stężenie rtęci\nZakres (0,0003 – 0,10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z techniką amalgamacji PB/RLS/25 wydanie 1 z 15.06.2012 r. Woda, scieki Stezenie rteci\nZakres (0,0003 – 0,10) mg/l\nMetoda absorpcyjnej spektrometrii atomowej z technika amalgamacji PB/RLS/25 wydanie 1 z 15.06.2012 r.","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury concentration","parameters_en":[{"name":"Range","range":"(0,0003 – 0,10) mg/l"}],"search_en":"Water, wastewater Mercury concentration Atomic absorption spectrometry with amalgamation technique Range PB/RLS/25 wydanie 1 z 15.06.2012 r.","technique_en":"Atomic absorption spectrometry with amalgamation technique","test_object_en":"Water, wastewater","methodology_zh":"汞浓度","parameters_zh":[{"name":"范围","range":"(0,0003 – 0,10) mg/l"}],"search_zh":"水、废水 汞浓度 原子吸收光谱法（汞齐化技术） 范围 PB/RLS/25 wydanie 1 z 15.06.2012 r.","technique_zh":"原子吸收光谱法（汞齐化技术）","test_object_zh":"水、废水"},{"_id":"6a83773faf14b9c0e7b1f795","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":"Metoda manualna","techniques":["Metoda manualna"],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna","reference":"PN-ISO 5667-10:2021-11","norm_bases":["PN-ISO 5667-10:2021-11"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i roztopowe Pobieranie próbek do badań chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11 Wody opadowe i roztopowe Pobieranie probek do badan chemicznych i fizycznych\nMetoda manualna PN-ISO 5667-10:2021-11","categories":["water"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Rainwater and snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11","technique_en":"Manual method","test_object_en":"Rainwater and snowmelt water","methodology_zh":"化学与物理检测用样品采集","search_zh":"雨水与融雪水 化学与物理检测用样品采集 手工法 PN-ISO 5667-10:2021-11","technique_zh":"手工法","test_object_zh":"雨水与融雪水"},{"_id":"6a83773faf14b9c0e7b1f796","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Wody opadowe i roztopowe","methodology":"Zawiesiny ogólne","parameters":[{"name":"Zakres","range":"(5,0 - 2000) mg/l"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawiesiny ogólne\nZakres (5,0 - 2000) mg/l\nMetoda wagowa","reference":"PN-EN 872:2007+Ap1:2007","norm_bases":["PN-EN 872:2007+Ap1:2007"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wody opadowe i roztopowe Zawiesiny ogólne\nZakres (5,0 - 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007 Wody opadowe i roztopowe Zawiesiny ogolne\nZakres (5,0 - 2000) mg/l\nMetoda wagowa PN-EN 872:2007+Ap1:2007","categories":["water"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total suspended solids (TSS)","parameters_en":[{"name":"Range","range":"(5,0 - 2000) mg/l"}],"search_en":"Rainwater and snowmelt water Total suspended solids (TSS) Gravimetric method Range PN-EN 872:2007+Ap1:2007","technique_en":"Gravimetric method","test_object_en":"Rainwater and snowmelt water","methodology_zh":"总悬浮物","parameters_zh":[{"name":"范围","range":"(5,0 - 2000) mg/l"}],"search_zh":"雨水与融雪水 总悬浮物 重量法 范围 PN-EN 872:2007+Ap1:2007","technique_zh":"重量法","test_object_zh":"雨水与融雪水"},{"_id":"6a83773faf14b9c0e7b1f797","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 – 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna","reference":"PN-EN 12176:2004","norm_bases":["PN-EN 12176:2004"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN 12176:2004 Osady sciekowe pH\nZakres (4,0 – 10,0)\nMetoda potencjometryczna PN-EN 12176:2004","categories":["water"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 – 10,0)"}],"search_en":"Sewage sludge pH Potentiometric method Range PN-EN 12176:2004","technique_en":"Potentiometric method","test_object_en":"Sewage sludge","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 – 10,0)"}],"search_zh":"污泥 pH 值 电位法 范围 PN-EN 12176:2004","technique_zh":"电位法","test_object_zh":"污泥"},{"_id":"6a83773faf14b9c0e7b1f798","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Sucha masa / Zawartośc wody","parameters":[{"name":"Zakres","range":"(0,5 - 99,5)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Sucha masa / Zawartośc wody\nZakres (0,5 - 99,5)%\nMetoda wagowa","reference":"PN-EN 12880:2004","norm_bases":["PN-EN 12880:2004"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Sucha masa / Zawartośc wody\nZakres (0,5 - 99,5)%\nMetoda wagowa PN-EN 12880:2004 Osady sciekowe Sucha masa / Zawartosc wody\nZakres (0,5 - 99,5)%\nMetoda wagowa PN-EN 12880:2004","categories":["water"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,5 - 99,5)%"}],"search_en":"Sewage sludge Gravimetric method Range PN-EN 12880:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,5 - 99,5)%"}],"search_zh":"污泥 重量法 范围 PN-EN 12880:2004","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a83773faf14b9c0e7b1f799","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Strata przy prażeniu suchej masy / Pozostałość po prażeniu","parameters":[{"name":"Zakres","range":"(0,5 - 99,5)%"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Strata przy prażeniu suchej masy / Pozostałość po prażeniu\nZakres (0,5 - 99,5)%\nMetoda wagowa","reference":"PN-EN 12879:2004","norm_bases":["PN-EN 12879:2004"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Strata przy prażeniu suchej masy / Pozostałość po prażeniu\nZakres (0,5 - 99,5)%\nMetoda wagowa PN-EN 12879:2004 Osady sciekowe Strata przy prazeniu suchej masy / Pozostalosc po prazeniu\nZakres (0,5 - 99,5)%\nMetoda wagowa PN-EN 12879:2004","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(0,5 - 99,5)%"}],"search_en":"Sewage sludge Gravimetric method Range PN-EN 12879:2004","technique_en":"Gravimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,5 - 99,5)%"}],"search_zh":"污泥 重量法 范围 PN-EN 12879:2004","technique_zh":"重量法","test_object_zh":"污泥"},{"_id":"6a83773faf14b9c0e7b1f79a","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu amonowego","parameters":[{"name":"Zakres","range":"(0,1 - 5,0)%"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu amonowego\nZakres (0,1 - 5,0)%\nMetoda miareczkowa","reference":"PN-75/C-04576/15","norm_bases":["PN-75/C-04576/15"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu amonowego\nZakres (0,1 - 5,0)%\nMetoda miareczkowa PN-75/C-04576/15 Osady sciekowe Zawartosc azotu amonowego\nZakres (0,1 - 5,0)%\nMetoda miareczkowa PN-75/C-04576/15","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen content","parameters_en":[{"name":"Range","range":"(0,1 - 5,0)%"}],"search_en":"Sewage sludge Ammonium nitrogen content Titrimetric method Range PN-75/C-04576/15","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,1 - 5,0)%"}],"search_zh":"污泥 氨氮含量 滴定法 范围 PN-75/C-04576/15","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"氨氮含量"},{"_id":"6a83773faf14b9c0e7b1f79b","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość azotu ogólnego Kjeldahla","parameters":[{"name":"Zakres","range":"(0,10 - 10)%"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu ogólnego Kjeldahla\nZakres (0,10 - 10)%\nMetoda miareczkowa","reference":"PN-EN 13342:2002","norm_bases":["PN-EN 13342:2002"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość azotu ogólnego Kjeldahla\nZakres (0,10 - 10)%\nMetoda miareczkowa PN-EN 13342:2002 Osady sciekowe Zawartosc azotu ogolnego Kjeldahla\nZakres (0,10 - 10)%\nMetoda miareczkowa PN-EN 13342:2002","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total Kjeldahl nitrogen content","parameters_en":[{"name":"Range","range":"(0,10 - 10)%"}],"search_en":"Sewage sludge Total Kjeldahl nitrogen content Titrimetric method Range PN-EN 13342:2002","technique_en":"Titrimetric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(0,10 - 10)%"}],"search_zh":"污泥 凯氏总氮含量 滴定法 范围 PN-EN 13342:2002","technique_zh":"滴定法","test_object_zh":"污泥","methodology_zh":"凯氏总氮含量"},{"_id":"6a83773faf14b9c0e7b1f79c","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(1,0 – 5,0)%"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu ogólnego\nZakres (1,0 – 5,0)%\nMetoda spektrofotometryczna","reference":"PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt 4 +Ap1:2010 + Ap2:2010","norm_bases":["PN-EN 14672:2006","PN-EN ISO 6878:2006 pkt 4 +Ap1:2010 + Ap2:2010"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość fosforu ogólnego\nZakres (1,0 – 5,0)%\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt 4 +Ap1:2010 + Ap2:2010 Osady sciekowe Zawartosc fosforu ogolnego\nZakres (1,0 – 5,0)%\nMetoda spektrofotometryczna PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt 4 +Ap1:2010 + Ap2:2010","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total phosphorus content","parameters_en":[{"name":"Range","range":"(1,0 – 5,0)%"}],"search_en":"Sewage sludge Total phosphorus content Spectrophotometric method Range PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt 4 +Ap1:2010 + Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围","range":"(1,0 – 5,0)%"}],"search_zh":"污泥 总磷含量 分光光度法 范围 PN-EN 14672:2006 | PN-EN ISO 6878:2006 pkt 4 +Ap1:2010 + Ap2:2010","technique_zh":"分光光度法","test_object_zh":"污泥","methodology_zh":"总磷含量"},{"_id":"6a83773faf14b9c0e7b1f79d","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Zawartość metali","parameters":[{"name":"Zakres"},{"name":"Chrom","range":"(5 - 3000) mg/kg"},{"name":"Ołów","range":"(5 - 2000) mg/kg"},{"name":"Cynk","range":"(20 - 7000) mg/kg"},{"name":"Kadm","range":"(1 - 100) mg/kg"},{"name":"Nikiel","range":"(5 - 1000) mg/kg"},{"name":"Miedź","range":"(20 - 4000) mg/kg"},{"name":"Wapń","range":"(1 - 60)%"},{"name":"Magnez","range":"(0,2 - 10)%"}],"technique":"Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","techniques":["Metoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)"],"computed":[],"activity":"Zawartość metali\nZakres:\nZakres\nChrom (5 - 3000) mg/kg\nOłów (5 - 2000) mg/kg\nCynk (20 - 7000) mg/kg\nKadm (1 - 100) mg/kg\nNikiel (5 - 1000) mg/kg\nMiedź (20 - 4000) mg/kg\nWapń (1 - 60)%\nMagnez (0,2 - 10)%\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES)","reference":"PN-EN ISO 11885:2009 | PN-EN 13346:2002","norm_bases":["PN-EN ISO 11885:2009","PN-EN 13346:2002"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Zawartość metali\nZakres:\nZakres\nChrom (5 - 3000) mg/kg\nOłów (5 - 2000) mg/kg\nCynk (20 - 7000) mg/kg\nKadm (1 - 100) mg/kg\nNikiel (5 - 1000) mg/kg\nMiedź (20 - 4000) mg/kg\nWapń (1 - 60)%\nMagnez (0,2 - 10)%\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 13346:2002 Osady sciekowe Zawartosc metali\nZakres:\nZakres\nChrom (5 - 3000) mg/kg\nOlow (5 - 2000) mg/kg\nCynk (20 - 7000) mg/kg\nKadm (1 - 100) mg/kg\nNikiel (5 - 1000) mg/kg\nMiedz (20 - 4000) mg/kg\nWapn (1 - 60)%\nMagnez (0,2 - 10)%\nMetoda emisyjnej spektrometrii atomowej ze wzbudzeniem w plazmie indukcyjnie sprzezonej (ICP-OES) PN-EN ISO 11885:2009 | PN-EN 13346:2002","categories":["materials","water"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Metal content","parameters_en":[{"name":"Range"},{"name":"Chromium","range":"(5 - 3000) mg/kg"},{"name":"Lead","range":"(5 - 2000) mg/kg"},{"name":"Zinc","range":"(20 - 7000) mg/kg"},{"name":"Cadmium","range":"(1 - 100) mg/kg"},{"name":"Nickel","range":"(5 - 1000) mg/kg"},{"name":"Copper","range":"(20 - 4000) mg/kg"},{"name":"Calcium","range":"(1 - 60)%"},{"name":"Magnesium","range":"(0,2 - 10)%"}],"search_en":"Sewage sludge Metal content Inductively coupled plasma optical emission spectrometry (ICP-OES) Range Chromium Lead Zinc Cadmium Nickel Copper Calcium Magnesium PN-EN ISO 11885:2009 | PN-EN 13346:2002","technique_en":"Inductively coupled plasma optical emission spectrometry (ICP-OES)","test_object_en":"Sewage sludge","parameters_zh":[{"name":"范围"},{"name":"铬","range":"(5 - 3000) mg/kg"},{"name":"铅","range":"(5 - 2000) mg/kg"},{"name":"锌","range":"(20 - 7000) mg/kg"},{"name":"镉","range":"(1 - 100) mg/kg"},{"name":"镍","range":"(5 - 1000) mg/kg"},{"name":"铜","range":"(20 - 4000) mg/kg"},{"name":"钙","range":"(1 - 60)%"},{"name":"镁","range":"(0,2 - 10)%"}],"search_zh":"污泥 金属含量 电感耦合等离子体原子发射光谱法（ICP-OES） 范围 铬 铅 锌 镉 镍 铜 钙 镁 PN-EN ISO 11885:2009 | PN-EN 13346:2002","technique_zh":"电感耦合等离子体原子发射光谱法（ICP-OES）","test_object_zh":"污泥","methodology_zh":"金属含量"},{"_id":"6a83773faf14b9c0e7b1f79e","lab_id":"69ad52a3de79e566650fb320","country":"PL","accr_number":"AB 610","accr_body":"PCA","test_object":"Osady ściekowe","methodology":"Pobieranie próbek do badań chemicznych i fizycznych","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Pobieranie próbek do badań chemicznych i fizycznych","reference":"PN-EN ISO 5667-13:2011, z wyłączeniem pkt 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.9, 6.3.10","norm_bases":["PN-EN ISO 5667-13:2011, z wyłączeniem pkt 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.9, 6.3.10"],"lab_section":"Laboratorium Centralne; Laboratorium Analiz Ścieków","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Osady ściekowe Pobieranie próbek do badań chemicznych i fizycznych PN-EN ISO 5667-13:2011, z wyłączeniem pkt 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.9, 6.3.10 Osady sciekowe Pobieranie probek do badan chemicznych i fizycznych PN-EN ISO 5667-13:2011, z wylaczeniem pkt 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.9, 6.3.10","categories":["water"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sampling for chemical and physical testing","search_en":"Sewage sludge Sampling for chemical and physical testing PN-EN ISO 5667-13:2011, z wyłączeniem pkt 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.9, 6.3.10","test_object_en":"Sewage sludge","methodology_zh":"化学与物理检测用样品采集","search_zh":"污泥 化学与物理检测用样品采集 PN-EN ISO 5667-13:2011, z wyłączeniem pkt 6.3.3, 6.3.4, 6.3.5, 6.3.7, 6.3.8, 6.3.9, 6.3.10","test_object_zh":"污泥"}],"has_pdf":true}