🇵🇱 WOJEWÓDZKA STACJA SANITARNO-EPIDEMIOLOGICZNA PL
Water & wastewaterFood & beveragesMicrobiologyMaterials & polymersPharma & cosmetics
WOJEWÓDZKA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 601 (Kraków, Poland). Its accreditation scope covers 179 test methods in the following areas: Water & wastewater, Food & beverages, Microbiology, Materials & polymers. Test objects include: Water intended for human consumption, Water (including swimming pool water), Food E, Water E. Most frequently used techniques: Spectrophotometric method, Titrimetric method, Membrane filtration method.
At a glance
- Accreditation number: PCA AB 601
- Methods in scope: 179
- Types of test objects: 40
- Techniques used: 43
- City: Kraków, Poland
- Accreditation number
- AB 601
- Accreditation body
- PCA
- Address
- W KRAKOWIE, ul. Prądnicka 76, 31-202 Kraków
- City
- Kraków, Poland
What this laboratory tests (40)
- Water intended for human consumption — 58 methods
- Water (including swimming pool water) — 41 methods
- Food E — 24 methods
- Water E — 7 methods
- Meat and meat products — 4 methods
- Faeces — 3 methods
- Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci — 3 methods
- Workplace environment - electromagnetic fields — 3 methods
- Faeces E — 2 methods
- Fruit, vegetables and their products — 2 methods
- Water intended for human consumption, Swimming pool water — 2 methods
- Żywność E, Obiekty z obszaru produkcji żywności E — 2 methods
- Bacterial strains — 1 method
- Biological indicators for the control of the effectiveness of the sterilization process — 1 method
- Ceramic articles and silicate surfaces of non-ceramic articles intended to come into contact with food — 1 method
- and 25 more
Analytical techniques used (43)
- Spectrophotometric method — 34 methods
- Titrimetric method — 20 methods
- Membrane filtration method — 14 methods
- High-performance liquid chromatography with diode array detection (HPLC-DAD) — 8 methods
- Plate method (pour plate) — 8 methods
- Conductometric method — 6 methods
- Culture method with biochemical and serological confirmation — 6 methods
- Flame atomic absorption spectrometry (FAAS) — 6 methods
- Potentiometric method — 6 methods
- MPN method — 5 methods
- Nephelometric method — 5 methods
- High-performance liquid chromatography with fluorescence detection (HPLC-FLD) — 4 methods
- Culture method with biochemical confirmation — 3 methods
- Direct measurement method — 3 methods
- Gravimetric method — 3 methods
- and 28 more
Laboratory sections (8)
- Oddział Laboratoryjny w Tarnowie — 44 methods
- ODDZIAŁ LABORATORYJNY BADANIA WODY — 41 methods
- ODDZIAŁ LABORATORYJNY w WADOWICACH — 25 methods
- ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH — 18 methods
- ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH — 17 methods
- ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI — 14 methods
- Dział Laboratoryjny – obszar higieny radiacyjnej — 13 methods
- ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ — 7 methods
Laboratory locations
- ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI — ul. Prądnicka 76, 31-202 Kraków
- ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH — ul. Prądnicka 76, 31-202 Kraków
- ODDZIAŁ LABORATORYJNY BADANIA WODY — ul. Prądnicka 76, 31-202 Kraków
- Dział Laboratoryjny – obszar higieny radiacyjnej — ul. Prądnicka 76, 31-202 Kraków
- ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ — ul. Prądnicka 76, 31-202 Kraków
- Oddział Laboratoryjny w Tarnowie — ul. Ignacego Mościckiego 10; 33-100 Tarnów
- ODDZIAŁ LABORATORYJNY w WADOWICACH — ul. Teatralna 2, 34-100 Wadowice
Accreditation scope — test methods (179)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH | |||||
| 1 | Food E | Content of metals and other elements Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Flame atomic absorption spectrometry (FAAS) | Procedury opracowane przez laboratorium Normy | |
| 2 | Food E | Content of metals and other elements Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Hydride generation atomic absorption spectrometry (HG AAS) | Procedury opracowane przez laboratorium Normy | |
| 3 | Food E | Mercury content Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CV AAS) | PB-LZ/LI-03 | |
| 4 | Food E | Content of metals and other elements Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Electrothermal atomization atomic absorption spectrometry (ET AAS) | Procedury opracowane przez laboratorium Normy | |
| 5 | Food E | Mycotoxin content Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | Procedury opracowane przez laboratorium Normy | |
| 6 | Food E | Mycotoxin content Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | Procedury opracowane przez laboratorium Normy | |
| 7 | Food E | Polycyclic aromatic hydrocarbons (PAH) content Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | Procedury opracowane przez laboratorium | |
| 8 | Food E | Colourant content Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | Procedury opracowane przez laboratorium | |
| 9 | Food E | Zawartość środków słodzących Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | Normy | |
| 10 | Food E | Preservative content Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | Normy | |
| 11 | Food E | Caffeine content Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | Normy | |
| 12 | Food E | Vitamin content Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | Procedury opracowane przez laboratorium | |
| 13 | Food E | Fatty acid content Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Gas chromatography with flame ionization detection (GC-FID) | PB-LI-26 | |
| 14 | Ceramic articles and silicate surfaces of non-ceramic articles intended to come into contact with food | Migracja metali: ołowiu i kadmu Lead Range (0,2 -100,0) mg/dm3 Range (0,02 - 10,0) mg/dm2 Range (0,02 – 10,0) mg/obrzeże Cadmium Range (0,02 - 5,0) mg/dm3 Range (0,002 - 0,5) mg/dm2 Range (0,002 – 0,5) mg/obrzeże |
Flame atomic absorption spectrometry (FAAS) | PN-EN 1388-1:2000+Ap1:2002 | PN-EN 1388-2:2000 | |
| 15 | Cosmetics – toothpastes | Fluorine content Range (0,03 - 0,23) % |
Gas chromatography with flame ionization detection (GC-FID) | PB-LI-31 wydanie nr 6 z dnia 01.12.2025 r. | |
| 16 | Fish, seafood and their products | Histamine content Range (10 - 450) mg/kg |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | PN-EN ISO 19343:2017-08 | |
| 17 | Wyroby przeznaczone do kontaktu z żywnością wykonane z poliamidu | Migracja pierwszorzędowych amin aromatycznych (PAAs) do płynu modelowego 3% kwasu octowego Range 2,6-toluenodiamina (2,6-TDA) Range (0,002 - 0,64) mg/kg 2,4-toluenediamine (2,4-TDA) (0,002 - 0,64) mg/kg 1,5-diaminonaphthalene (1,5-DAN) (0,002 - 0,64) mg/kg aniline (ANL) (0,002 - 0,64) mg/kg 4,4ꞌ-oxydianiline (4,4-DPE) (0,002 - 0,64) mg/kg 4,4ꞌ-diaminodiphenylmethane (4,4-MDA) (0,002 - 0,64) mg/kg 3,3ꞌ-dimethylbenzidine (3,3-DMB) (0,002 - 0,64) mg/kg 1,3-phenylenediamine (0,002 - 0,64) mg/kg Sum of PAAs migration (calculated) |
High-performance liquid chromatography with diode array detection (HPLC-DAD) | PB-LZ/LI-8 wydanie nr 7 z dnia 21.11.2025 r. | |
| 18 | Wyroby przeznaczone do kontaktu z żywnością | Migration of bisphenol A into food simulants - 3% acetic acid, 10% ethanol, 20% ethanol, 50% ethanol Range (0,002 - 0,5) mg/kg |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PB-LZ/LI-12 wydanie nr 2 z dnia 21.11.2025 r. | |
| ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI | |||||
| 19 | Meat and meat products | Total and added phosphorus content Total phosphorus Range (0,2 - 2,0) g/100 g (jako P2O5) Added phosphorus (calculated) |
Spectrophotometric method | PN-ISO 13730:1999+Ap1:2004 | |
| 20 | Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci | Fat content Range (0,02 -24,0) % |
Extraction-gravimetric method | PB-LZ-05 wydanie nr 5 z dnia 21.11.2025 r. | |
| 21 | Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci | Water content Range (0,8 -96,7) % Dry matter content Range (3,3 -99,2) % |
Gravimetric method; Gravimetric method | PB-LZ-01 wydanie nr 2 z dnia 08.01.2026 r. | |
| 22 | Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci | Total ash content Range (0,1 -11,8) % |
Gravimetric method | PB-LZ-02 wydanie nr 2 z dnia 08.01.2026 r. | |
| 23 | Plastic materials and articles intended to come into contact with food | Overall migration by the pouch method, by total immersion, using a test cell, by filling the article, into food simulants: Water (2,0 - 200,0) mg/dm2 Range (12,0 - 400,0) mg/kg 3% acetic acid (2,0 - 200,0) mg/dm2 (12,0 - 400,0) mg/kg 10% ethanol (2,0 - 200,0) mg/dm2 (12,0 - 400,0) mg/kg 20% ethanol (2,0 - 200,0) mg/dm2 (12,0 - 400,0) mg/kg 50% ethanol (2,0 - 200,0) mg/dm2 (12,0 - 400,0) mg/kg 95% ethanol (2,0 - 200,0) mg/dm2 (12,0 - 400,0) mg/kg Isooctane (2,0 - 200,0) mg/dm2 (12,0 - 400,0) mg/kg |
Gravimetric method | PN-EN 1186-3:2023-01 | |
| 24 | Melamine-formaldehyde moulding compounds | Migracja specyficzna formaldehydu do płynu modelowego 3% kwasu octowego Range (3,0 – 30,0) mg/kg |
Spectrophotometric method | CN/TS 13130-23:2005 | |
| 25 | Food E | Vitamin C content Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Titrimetric method | Normy | |
| 26 | Oleje oraz tłuszcze roślinne i zwierzęce E | Rancidity parameters Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Titrimetric method | Normy | |
| 27 | Food E | Sulfur dioxide content Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Titrimetric method | Normy | |
| 28 | Food E | Element content Zawartość związków (z obliczeń) Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Titrimetric method | Procedury badawcze | |
| 29 | Żywność E, Obiekty z obszaru produkcji żywności E | Presence of microorganisms Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Culture method with biochemical and serological confirmation | Normy | |
| 30 | Żywność E, Kosmetyki E | Presence of microorganisms Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Culture method with biochemical confirmation | Normy | |
| 31 | Żywność E, Kosmetyki E, Obiekty z obszaru produkcji żywności E | Microorganism count Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Plate method (pour plate) | Normy | |
| 32 | Żywność E, Obiekty z obszaru produkcji żywności E | Microorganism count Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Plate method (spread plate) | Normy | |
| ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH | |||||
| 33 | Water (including swimming pool water) | Manganese concentration Range (30 - 10000) μg/l |
Flame atomic absorption spectrometry (FAAS) | PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r. | |
| 34 | Water (including swimming pool water) | Stężenie miedzi i cynku Copper (0,04 - 25) mg/l Zinc (0,20 - 10) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002, metoda A | |
| 35 | Water (including swimming pool water) | Sodium concentration Range (2,50 - 500) mg/l |
Flame atomic emission spectrometry (FAES) | PN-ISO 9964-3:1994 | |
| 36 | Water (including swimming pool water) | Concentration of lead, cadmium, nickel, chromium, aluminium, manganese, antimony, arsenic, selenium, boron, silver, copper and mercury Lead (1,0 - 100) μg/l Cadmium (0,50 - 50) μg/l Nickel (1,0 - 100) μg/l Chromium (5,0 - 100) μg/l Aluminium (10,0 - 2000) μg/l Manganese (5,0 - 100) μg/l Antimony (0,50 - 50) μg/l Arsenic (1,0 - 100) μg/l Selenium (1,0 - 100) μg/l Boron (50 - 5000) μg/l Silver (0,5 - 100) μg/l Copper (5,0 - 2100) μg/l Mercury (0,10 - 5,0) μg/l |
Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS) | PN-EN ISO 17294-2:2024-04 | |
| 37 | Water (including swimming pool water) | Stężenie łatwolotnych chlorowcopochodnych węglowodorów Trichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM): Range (5,0 - 120) μg/l Sum of THM (calculated) |
Gas chromatography with electron capture detection (GC-ECD) | PN-EN ISO 10301:2002 Rozdział 2 | |
| 38 | Water (including swimming pool water) | Anion concentrations Chlorides (1,0 - 1000) mg/l Nitrates (1,0 - 1000) mg/l Fluorides (0,10 - 10) mg/l Sulfates (1,0 - 1000) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 +AC:2012 | |
| 39 | Water intended for human consumption | Manganese concentration Range (30 - 10000) μg/l |
Flame atomic absorption spectrometry (FAAS) | PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r. | |
| 40 | Water intended for human consumption | Stężenie miedzi i cynku Copper (0,04 - 25) mg/l Zinc (0,20 - 10) mg/l |
Flame atomic absorption spectrometry (FAAS) | PN-ISO 8288:2002, metoda A | |
| 41 | Water intended for human consumption | Sodium concentration Range (2,50 - 500) mg/l |
Flame atomic emission spectrometry (FAES) | PN-ISO 9964-3:1994 | |
| 42 | Water intended for human consumption | Anion concentrations Chlorides (1,0 - 1000) mg/l Nitrites (0,030 - 10) mg/l Nitrates (1,0 - 1000) mg/l Fluorides (0,10 - 10) mg/l Sulfates (1,0 - 1000) mg/l |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-1:2009 +AC:2012 | |
| 43 | Water intended for human consumption | Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi, rtęci i uranu Lead (1,0 - 100) μg/l Cadmium (0,50 - 50) μg/l Nickel (1,0 - 100) μg/l Chromium (5,0 - 100) μg/l Aluminium (10,0 - 2000) μg/l Manganese (5,0 - 100) μg/l Antimony (0,50 - 50) μg/l Arsenic (1,0 - 100) μg/l Selenium (1,0 - 100) μg/l Boron (50 - 5000) μg/l Silver (0,5 - 100) μg/l Copper (5,0 - 2100) μg/l Mercury (0,10 - 5,0) μg/l Uranium (1,0 - 100) μg/l |
Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS) | PN-EN ISO 17294-2:2024-04 | |
| 44 | Water intended for human consumption | Stężenie łatwolotnych chlorowcopochodnych węglowodorów: Trichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM) Range (5,0 -120) μg/l Tetrachloroeten, trichloroeten (1,0 - 20,5) μg/l Tetrachloromethane (0,20 - 4,10) μg/l 1,2-dichloroethane (0,80 - 6,4) μg/l Sum of THM (calculated) Suma tetrachloroetenu i trichloroetenu ( z obliczeń) |
Gas chromatography with electron capture detection (GC-ECD, HS-GC-ECD) | PN-EN ISO 10301:2002 Rozdział 2 i 3 | |
| 45 | Water intended for human consumption | Pesticide concentration Aldrin (0,005 - 0,060) μg/l Dieldrin (0,005 - 0,060) μg/l Heptachlor (0,005 - 0,060) μg/l Heptachlor endo-epoxyd A Range (0,005 - 0,060) μg/l Heptachlor exo-epoxyd B (0,005 - 0,060) μg/l Chlordane-cis (0,010 - 0,120) μg/l Chlordane-trans (0,010 - 0,120) μg/l DDD (0,010 - 0,120) μg/l DDE (0,010 - 0,120) μg/l DDT (0,010 - 0,120) μg/l Endosulfan α (0,010 - 0,120) μg/l Endosulfan β (0,010 - 0,120) μg/l Trifluralin (0,010 - 0,120) μg/l PeCB (0,010- 0,120) μg/l HCB (0,010 - 0,120) μg/l HCH α (0,010 - 0,120) μg/l HCH β (0,010 - 0,120) μg/l HCH γ (0,010 - 0,120) μg/l HCH δ (0,010 - 0,120) μg/l Permethrin (0,010 - 0,120) μg/l Cypermethrin (0,010 - 0,120) μg/l Fenvalerate (0,010 - 0,120) μg/l Deltamethrin (0,010 - 0,120) μg/l Sum of pesticides (calculated) |
Gas chromatography with electron capture detection (GC-ECD) | PN-EN ISO 6468:2002 | |
| 46 | Water intended for human consumption | Chlorite concentration Range (0,050 - 10) mg/l Chlorate concentration Range (0,050 - 10) mg/l Sum of chlorites and chlorates (calculated) |
Ion chromatography with conductometric detection (IC-CD) | PN-EN ISO 10304-4:2022-08 | |
| 47 | Water intended for human consumption | Bromate concentration Range (2,0 - 50) μg/l |
Ion chromatography with spectrophotometric detection (IC-UV/VIS) | PN-EN ISO 11206:2013-07 | |
| 48 | Water intended for human consumption | Concentration of polycyclic aromatic hydrocarbons (PAH) Benzo(b)fluoranthene Range (0,0020 - 0,030) μg/l Benzo(k)fluoranthene (0,0020 - 0,030) μg/l Benzo(ghi)perylene (0,0020 - 0,030) μg/l Indeno (1,2,3-cd)piren (0,0020 - 0,030) μg/l Sum of PAH (calculated) Benzo(a)pyrene Range (0,0020 - 0,030) μg/l |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD); High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PB-LI-16 wydanie nr 5 z dnia 02.12.2025 r. | |
| 49 | Water intended for human consumption | Bisphenol A concentration Range (0,50 – 7,5) μg/l |
High-performance liquid chromatography with fluorescence detection (HPLC-FLD) | PB-LI-37 wydanie nr 2 z dnia 19.12.2025 r. | |
| ODDZIAŁ LABORATORYJNY BADANIA WODY | |||||
| 50 | Water (including swimming pool water) | Iron concentration Range (20,0 - 1000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 51 | Water (including swimming pool water) | pH Range (4,0 - 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 52 | Water (including swimming pool water) | Electrical conductivity Range (84 - 5000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 53 | Water (including swimming pool water) | Ammonium nitrogen concentration Range (0,060 - 1,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 54 | Water (including swimming pool water) | Turbidity Range (0,20 - 10) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 55 | Water (including swimming pool water) | Total organic carbon concentration Range (1,0 - 25) mg/l |
High-temperature combustion with IR detection | PN-EN 1484:1999 | |
| 56 | Water (including swimming pool water) | Permanganate index (oxidisability) Range (0,55 - 10,0) mg/l |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 57 | Water (including swimming pool water) | Chloride concentration Range (5,0 - 5000) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 58 | Water intended for human consumption | Iron concentration Range (20,0 - 1000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 59 | Water intended for human consumption | pH Range (4,0 - 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 60 | Water intended for human consumption | Electrical conductivity Range (84- 5000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 61 | Water intended for human consumption | Ammonium nitrogen concentration Range (0,060 - 1,0) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 62 | Water intended for human consumption | Turbidity Range (0,20 - 10) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 63 | Water intended for human consumption | Total organic carbon concentration Range (1,0 - 25) mg/l |
High-temperature combustion with IR detection | PN-EN 1484:1999 | |
| 64 | Water intended for human consumption | Permanganate index (oxidisability) Range (0,55 - 10,0) mg/l |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 65 | Water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (5 - 1000) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 66 | Water intended for human consumption | Calcium concentration Range (2 - 100) mg/l |
Titrimetric method | PN-ISO 6058:1999 | |
| 67 | Water intended for human consumption | Magnesium concentration (calculated) | PN-C-04554-4:1999 Załącznik A | ||
| 68 | Water intended for human consumption | Chloride concentration Range (5,0 - 300) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 69 | Water (including swimming pool water) | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 70 | Water (including swimming pool water) | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 71 | Water (including swimming pool water) | Most probable number of Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 72 | Water (including swimming pool water) | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 73 | Water (including swimming pool water) | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 74 | Water (including swimming pool water) | Total count of microorganisms at 36oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 75 | Water (including swimming pool water) | Coagulase-positive staphylococci count | Membrane filtration method | Metodyka PZH ZHK z dnia 23.04.2007 r. | |
| 76 | Water (including swimming pool water) | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 77 | Water intended for human consumption | Coliform bacteria count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 78 | Water intended for human consumption | Escherichia coli count | Membrane filtration method | PN-EN ISO 9308-1:2014-12 +A1:2017-04 | |
| 79 | Water intended for human consumption | Most probable number of coliform bacteria | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 80 | Water intended for human consumption | Most probable number of Escherichia coli | MPN method | PN-EN ISO 9308-2:2014-06 | |
| 81 | Water intended for human consumption | Total count of microorganisms at a temperature of 22oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 82 | Water intended for human consumption | Total count of microorganisms at 36oC | Plate method (pour plate) | PN-EN ISO 6222:2004 | |
| 83 | Water intended for human consumption | Pseudomonas aeruginosa count | Membrane filtration method | PN-EN ISO 16266:2009 | |
| 84 | Water intended for human consumption | Intestinal enterococci count | Membrane filtration method | PN-EN ISO 7899-2:2004 | |
| 85 | Water intended for human consumption | Count of Clostridium perfringens bacteria (including spores) | Membrane filtration method | PN-EN ISO 14189:2016-10 | |
| 86 | Water intended for human consumption | Count of bacteria of the genus Legionella Matrix A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC) Posiew bezpośredni Matrix A Procedura 1 (pożywka BCYE i BCYE+AB) |
Membrane filtration method | PN-EN ISO 11731:2017-08 +Ap1:2019:12 | |
| 87 | Swimming pool water | Count of bacteria of the genus Legionella Matryca B Procedura 7 (pożywka GVPC) |
Membrane filtration method | PN-EN ISO 11731:2017-08 +Ap1:2019:12 | |
| 88 | Water intended for human consumption, Swimming pool water | Identyfikacja grup serologicznych bakterii z rodzaju Legionella | Metoda serologiczna, test aglutynacji lateksowej | Instrukcja producenta Oxoid Legionella Latex Test Wydanie X5057F, luty 2025 | |
| 89 | Water intended for human consumption, Swimming pool water | Identyfikacja grup serologicznych bakterii z rodzaju Legionella | Metoda serologiczna, test aglutynacji lateksowej | Instrukcja producenta BIOMAXIMA Legionella Latex Rapid Test Aktualizacja 13.10.2025 | |
| 90 | Water intended for human consumption | Somatic coliphage count | Metoda płytek dwuwarstwowych (DAL) | PN-EN ISO 10705-2:2005 | |
| Dział Laboratoryjny – obszar higieny radiacyjnej | |||||
| 91 | Workplace environment - electromagnetic field in the workspace from magnetotherapy devices | Magnetic flux density in the frequency range (20 - 50) Hz range 0,5 μT - 19 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331) |
Direct measurement method (simplified) | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 | |
| 92 | Workplace environment - electromagnetic fields | Electric field strength in the frequency band: 10 Hz - 400 kHz range 1 V/m - 50 kV/m 400 kHz - 3 MHz range (0,5 - 300) V/m 3 MHz - 6 GHz range (0,8 - 800) V/m Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331) |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | |
| 93 | Workplace environment - electromagnetic fields | Magnetic flux density in the frequency range: 0Hz range (0,1 - 1000) mT 10 Hz - 400 kHz range 0,1 μT - 19 mT Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331) |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | |
| 94 | Workplace environment - electromagnetic fields | Magnetic field strength in the frequency band: 27 MHz - 1,0 GHz range (0,015 - 8,0) A/m 800 MHz - 6 GHz (z obliczeń) Regulated area: Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego
Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331) |
Direct measurement method | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego | |
| 95 | Food, Agricultural products, Feed, Water, Water intended for human consumption | 137Cs radionuclide activity concentration Range (2,0 - 10000) Bq/kg |
Gamma-ray spectrometry method | PB-LFR-01 wydanie nr 5 z dnia 09.12.2021 r. | |
| 96 | Water intended for human consumption | Activity concentration of radionuclide 222Rn Range (5 - 200) Bq/l |
Liquid scintillation spectrometry method | PN-EN ISO 13164-4:2023-12 | |
| 97 | Water intended for human consumption | Activity concentration of radionuclide 3H Range (10 -200) Bq/l |
Liquid scintillation spectrometry method | PN-EN ISO 9698:2019-06 | |
| 98 | Equipment used in general digital radiography | Specialist tests | Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-12 wydanie nr 5 z dnia 11.01.2023 r. | ||
| 99 | Urządzenia stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii cyfrowej, Urządzenia stosowane w stomatologii – aparaty do zdjęć wewnątrzustnych | Specialist tests | Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-04 wydanie nr 8 z dnia 10.02.2025 r. | ||
| 100 | Equipment used in dental cone beam computed tomography | Specialist tests | Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-14 wydanie nr 5 z dnia 11.01.2023 r. | ||
| 101 | Equipment used in fluoroscopy and angiography | Specialist tests | Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-08 wydanie nr 8 z dnia 11.01.2023 r. | ||
| 102 | Equipment used in digital mammography | Specialist tests | Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-13 wydanie nr 6 z dnia 11.01.2023 r. | ||
| 103 | Monitors used for the display of medical images | Specialist tests | Załącznik nr 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-15 wydanie nr 5 z dnia 11.01.2023 r. | ||
| ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ | |||||
| 104 | Faeces, bacterial strains | Presence and identification of rods of the genera Salmonella and Shigella | Culture method with biochemical and serological confirmation | PB-LMK-01 wydanie nr 3 z dnia 10.11.2021 r. w oparciu o publikacje metodyczne | |
| 105 | Bacterial strains | Identyfikacja pałeczek z rodzaju Salmonella | Biochemical and serological method | Schemat White’a-Kauffmanna-Le Minora, 2007 ISO/TR 6579-3:2014 | |
| 106 | Faeces | Obecność chorobotwórczych i warunkowo chorobotwórczych Gram-ujemnych pałeczek jelitowych | Culture method with biochemical and serological confirmation | PB-LMK-02 wydanie nr 3 z dnia 22.12.2021 r. w oparciu o publikacje metodyczne | |
| 107 | Faeces | Presence of eggs and cysts of human intestinal parasites | Coproscopic methods | PB-LMK-05 wydanie nr 3 z dnia 07.12.2016 r. w oparciu o publikacje metodyczne | |
| 108 | Biological indicators for the control of the effectiveness of the sterilization process | Presence of indicator microorganisms Geobacillus stearothermophilus (Sporal A), Bacillus subtilis (Sporal S) | Culture method | PB-LMK-03 wydanie nr 3 z dnia 04.01.2021 r. w oparciu o instrukcje producentów stosowanych wskaźników procesu sterylizacji | |
| 109 | Faeces E | Obecność antygenów biologicznych czynników chorobotwórczych Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Immunochromatographic method (ICR) | Instrukcje producenta | |
| 110 | Faeces E | Obecność antygenów biologicznych czynników chorobotwórczych Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Enzyme immunoassay method (ELISA) | Instrukcje producenta | |
| Oddział Laboratoryjny w Tarnowie | |||||
| 111 | Water (including swimming pool water) | Turbidity Range (0,10 - 100) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 112 | Water (including swimming pool water) | Total iron concentration Range (0,020 - 10,0) mg/l |
Spectrophotometric method | PN-ISO 6332: 2001+Ap1:2016-06 | |
| 113 | Water (including swimming pool water) | Ammonium ion concentration Range (0,060 - 1,30) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 114 | Water (including swimming pool water) | Nitrite concentration Range (0,020 - 1,312) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 115 | Water (including swimming pool water) | Nitrate concentration Range (0,20 - 110,75) mg/l |
Spectrophotometric method | PN-C-04576-08:1982 | |
| 116 | Water (including swimming pool water) | pH Range (4,0 - 12,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 117 | Water (including swimming pool water) | Electrical conductivity Range (5 - 5000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 118 | Water (including swimming pool water) | Chloride concentration Range (8,0 - 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 119 | Water (including swimming pool water) | Aluminium concentration Range (0,020 - 0,60) mg/l |
Spectrophotometric method | PN-C-04605-02:1992 | |
| 120 | Water (including swimming pool water) | Permanganate index Range (0,50 - 10,0) mg/l |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 121 | Water (including swimming pool water) | Orthophosphate concentration Range (0,03 - 2,45) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 | |
| 122 | Water (including swimming pool water) | Colour Range (2,0 - 60) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C | |
| 123 | Water intended for human consumption | Turbidity Range (0,10 - 100) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 124 | Water intended for human consumption | Total content of calcium and magnesium (total hardness) Range (11 - 700) mg/l CaCO3 |
Titrimetric method | PN-ISO 6059:1999 | |
| 125 | Water intended for human consumption | Total iron concentration Range (0,020 - 10,0) mg/l |
Spectrophotometric method | PN-ISO 6332: 2001+Ap1:2016-06 | |
| 126 | Water intended for human consumption | Ammonium ion concentration Range (0,060 - 1,30) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 127 | Water intended for human consumption | Nitrite concentration Range (0,020 - 1,312) mg/l |
Spectrophotometric method | PN-EN 26777:1999 | |
| 128 | Water intended for human consumption | Nitrate concentration Range (0,20 - 110,75) mg/l |
Spectrophotometric method | PN-C-04576-08:1982 | |
| 129 | Water intended for human consumption | pH Range (4,0 - 12,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 130 | Water intended for human consumption | Electrical conductivity Range (5 - 5000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 131 | Water intended for human consumption | Chloride concentration Range (8,0 - 400) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 132 | Water intended for human consumption | Aluminium concentration Range (0,020 - 0,60) mg/l |
Spectrophotometric method | PN-C-04605-02:1992 | |
| 133 | Water intended for human consumption | Permanganate index Range (0,50 - 10,0) mg/l |
Titrimetric method | PN-EN ISO 8467:2001 | |
| 134 | Water intended for human consumption | Orthophosphate concentration Range (0,03 - 2,45) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 | |
| 135 | Water intended for human consumption | Colour Range (2,0 - 60) mg/lPt |
Spectrophotometric method | PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C | |
| 136 | Faeces | Presence of rods of the genus Salmonella and Shigella | Culture method supplemented with biochemical and serological tests | PB-LZT-10 wydanie nr 4 z dnia 11.02.2025 r. w oparciu o publikacje metodyczne | |
| 137 | Water E | Microorganism count Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Membrane filtration method | Normy | |
| 138 | Water E | Microorganism count Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Plate method (pour plate) | Normy | |
| 139 | Water E | Microorganism count Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
MPN method | Normy | |
| 140 | Food E | Presence of microorganisms Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Culture method with biochemical and serological confirmation | Normy | |
| 141 | Food E | Presence of microorganisms Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Culture method with biochemical confirmation | Normy | |
| 142 | Food E | Microorganism count Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Plate method (pour plate) | Normy | |
| 143 | Food E | Microorganism count Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Plate method (spread plate) | Normy | |
| 144 | Meat and meat products | Nitrogen content Range (0,19 - 29,8) % Protein content (calculated) |
Titrimetric method | PB-LZT-19 wydanie nr 2 z dnia 20.01.2021 r. | |
| 145 | Fruit, vegetables and their products | Nitrate content NaNO3 (10,20 - 9233,8) mg/kg NO3− (7,43 - 8321,0) mg/kg Nitrite content NaNO2 (1,30 - 1480) mg/kg NO2− (0,89 - 1000,0) mg/kg |
Spectrophotometric method | PN-A-75112:1992 pkt.3 | |
| 146 | Fruit, vegetables and their products | Sulfur dioxide content Range (3,78 - 3000) mg/kg |
Titrimetric method | PN-A-75101-23: 1990 pkt.3 +Az2:2002 | |
| 147 | Milk and milk products | Nitrate content NO3− (3,44 - 540,0) mg/kg NaNO3 (4,71 - 739,8) mg/kg Nitrite content NO2− (0,31 - 80,0) mg/kg NaNO2 (0,46 - 118,4) mg/kg |
Spectrophotometric method | PN-EN ISO 14673-1:2004+Ap1:2007 | |
| 148 | Meat and meat products | Nitrate content NaNO3 (12,2 - 2197,5) mg/kg NO3− (8,9 – 1604,2) mg/kg Nitrite content NaNO2 (4,0 - 300,0) mg/kg NO2− (2,7 - 201,0) mg/kg |
Spectrophotometric method | PN-A-82114:1974 | |
| 149 | Meat and meat products | Zawartość fosforu ogólnego i dodanego Total phosphorus content Range (140 - 13000) mg/kg P2O5 Added phosphorus content (calculated) |
Gravimetric method | PN-A-82060:1999 | |
| 150 | Table salt | Potassium iodide content Range (12,83 - 173) mg/kg |
Titrimetric method | PN-C-84081-34:1980 | |
| 151 | Fish, seafood and their products, Cereal-flour products and pastry products, Fruit-vegetable products, Vegetable and animal fats, Foodstuffs for particular uses, Food concentrates, Food supplements, Delicatessen and culinary products, Mustards, sauces, Milk products, Non-alcoholic beverages | Benzoic acid, sorbic acid content, Benzoic acid Range (10 - 10000) mg/l Range (10 - 10000) mg/kg Sorbic acid (15 - 10000 mg/l (15 - 10000) mg/kg |
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS) | PN-EN 12856:2002 | |
| 152 | Fish, seafood and their products, Cereal-flour products and pastry products, Fruit-vegetable products, Foodstuffs for particular uses, Food concentrates, Food supplements, Delicatessen and culinary products, Mustards, sauces, Milk products, Non-alcoholic beverages | Aspartame, acesulfame-K, saccharin content Aspartame Range (25 - 10000) mg/l Range (25 - 10000) mg/kg Acesulfame-K (10 - 10000) mg/l (10 - 10000) mg/kg Saccharin (5 - 10000) mg/l (5 - 10000) mg/kg |
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS) | PN-EN 12856:2002 | |
| 153 | Cereal-flour products and pastry products, Foodstuffs for particular uses, Food concentrates, Food supplements, Delicatessen and culinary products, Milk products, Non-alcoholic beverages | Caffeine content Range (10 - 10000) mg/l Range (10 - 30000) mg/kg |
High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS) | PN-EN 12856:2002 | |
| 154 | Spirit drinks | Hydrogen cyanide content Range (0,0088 - 13) g/hl 100% alkoholu etylowego |
Spectrophotometric method | PN-A-79529-13:2005 pkt. 5.3 | |
| ODDZIAŁ LABORATORYJNY w WADOWICACH | |||||
| 155 | Water (including swimming pool water) | pH Range (4,0 - 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 156 | Water (including swimming pool water) | Total iron concentration Range (30 - 750) μg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 157 | Water (including swimming pool water) | Nitrate concentration Range (1,00 - 110) mg/l |
Spectrophotometric method | PN-C-04576-08:1982 | |
| 158 | Water (including swimming pool water) | Electrical conductivity Range (88 - 3000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 159 | Water (including swimming pool water) | Ammonium ion concentration Range (0,070 - 1,50) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 160 | Water (including swimming pool water) | Chloride concentration Range (5,00 - 680) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 161 | Water (including swimming pool water) | Colour Range (5 - 40) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C | |
| 162 | Water intended for human consumption | pH Range (4,0 - 10,0) |
Potentiometric method | PN-EN ISO 10523:2012 | |
| 163 | Water intended for human consumption | Total iron concentration Range (30 – 8000) μg/l |
Spectrophotometric method | PN-ISO 6332:2001+Ap1:2016-06 | |
| 164 | Water intended for human consumption | Nitrate concentration Range (1,00 - 110) mg/l |
Spectrophotometric method | PN-C-04576-08:1982 | |
| 165 | Water intended for human consumption | Turbidity Range (0,10 - 100) NTU |
Nephelometric method | PN-EN ISO 7027-1:2016-09 | |
| 166 | Water intended for human consumption | Aluminium concentration Range (40 - 1000) μg/l |
Spectrophotometric method | PN-C-04605-02:1992 | |
| 167 | Water intended for human consumption | Electrical conductivity Range (88 - 3000) μS/cm |
Conductometric method | PN-EN 27888:1999 | |
| 168 | Water intended for human consumption | Ammonium ion concentration Range (0,070 - 1,50) mg/l |
Spectrophotometric method | PN-ISO 7150-1:2002 | |
| 169 | Water intended for human consumption | Chloride concentration Range (5,00 - 680) mg/l |
Titrimetric method | PN-ISO 9297:1994 | |
| 170 | Water intended for human consumption | Colour Range (5 - 40) mg/l Pt |
Spectrophotometric method | PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C | |
| 171 | Water intended for human consumption | Orthophosphate concentration Range (0,040 - 1,60) mg/l |
Spectrophotometric method | PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 | |
| 172 | Water E | Presence of microorganisms Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Culture method with biochemical and serological confirmation | Normy | |
| 173 | Water E | Microorganism count Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Membrane filtration method | Normy | |
| 174 | Water E | Microorganism count Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Plate method (pour plate) | Normy | |
| 175 | Water E | Microorganism count Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Miniaturized method, MPN | Normy | |
| 176 | Food E | Presence of microorganisms Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Culture method with biochemical and serological confirmation | Normy | |
| 177 | Food E | Presence of microorganisms Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Culture method with biochemical confirmation | Normy | |
| 178 | Food E | Microorganism count Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Plate method (pour plate) | Normy | |
| 179 | Food E | Microorganism count Regulated area: E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot. |
Plate method (spread plate) | Normy | |
Reference standards (88)
CN/TS 13130-23:2005
Instrukcja producenta BIOMAXIMA Legionella Latex Rapid Test Aktualizacja 13.10.2025
Instrukcja producenta Oxoid Legionella Latex Test Wydanie X5057F, luty 2025
Instrukcje producenta
Metodyka PZH ZHK z dnia 23.04.2007 r.
Normy
PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.
PB-LFR-01 wydanie nr 5 z dnia 09.12.2021 r.
PB-LFR-04 wydanie nr 8 z dnia 10.02.2025 r.
PB-LFR-08 wydanie nr 8 z dnia 11.01.2023 r.
PB-LFR-12 wydanie nr 5 z dnia 11.01.2023 r.
PB-LFR-13 wydanie nr 6 z dnia 11.01.2023 r.
PB-LFR-14 wydanie nr 5 z dnia 11.01.2023 r.
PB-LFR-15 wydanie nr 5 z dnia 11.01.2023 r.
PB-LI-16 wydanie nr 5 z dnia 02.12.2025 r.
PB-LI-26
PB-LI-31 wydanie nr 6 z dnia 01.12.2025 r.
PB-LI-37 wydanie nr 2 z dnia 19.12.2025 r.
PB-LMK-01 wydanie nr 3 z dnia 10.11.2021 r. w oparciu o publikacje metodyczne
PB-LMK-02 wydanie nr 3 z dnia 22.12.2021 r. w oparciu o publikacje metodyczne
PB-LMK-03 wydanie nr 3 z dnia 04.01.2021 r. w oparciu o instrukcje producentów stosowanych wskaźników procesu sterylizacji
PB-LMK-05 wydanie nr 3 z dnia 07.12.2016 r. w oparciu o publikacje metodyczne
PB-LZ-01 wydanie nr 2 z dnia 08.01.2026 r.
PB-LZ-02 wydanie nr 2 z dnia 08.01.2026 r.
PB-LZ-05 wydanie nr 5 z dnia 21.11.2025 r.
PB-LZ/LI-03
PB-LZ/LI-12 wydanie nr 2 z dnia 21.11.2025 r.
PB-LZ/LI-8 wydanie nr 7 z dnia 21.11.2025 r.
PB-LZT-10 wydanie nr 4 z dnia 11.02.2025 r. w oparciu o publikacje metodyczne
PB-LZT-19 wydanie nr 2 z dnia 20.01.2021 r.
PN-A-75101-23: 1990 pkt.3 +Az2:2002
PN-A-75112:1992 pkt.3
PN-A-79529-13:2005 pkt. 5.3
PN-A-82060:1999
PN-A-82114:1974
PN-C-04554-4:1999 Załącznik A
PN-C-04576-08:1982
PN-C-04605-02:1992
PN-C-84081-34:1980
PN-EN 1186-3:2023-01
PN-EN 12856:2002
PN-EN 1388-1:2000+Ap1:2002
PN-EN 1388-2:2000
PN-EN 1484:1999
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10301:2002 Rozdział 2
PN-EN ISO 10301:2002 Rozdział 2 i 3
PN-EN ISO 10304-1:2009 +AC:2012
PN-EN ISO 10304-4:2022-08
PN-EN ISO 10523:2012
PN-EN ISO 10705-2:2005
PN-EN ISO 11206:2013-07
PN-EN ISO 11731:2017-08 +Ap1:2019:12
PN-EN ISO 13164-4:2023-12
PN-EN ISO 14189:2016-10
PN-EN ISO 14673-1:2004+Ap1:2007
PN-EN ISO 16266:2009
PN-EN ISO 17294-2:2024-04
PN-EN ISO 19343:2017-08
PN-EN ISO 6222:2004
PN-EN ISO 6468:2002
PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12 +A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9698:2019-06
PN-ISO 13730:1999+Ap1:2004
PN-ISO 6058:1999
PN-ISO 6059:1999
PN-ISO 6332: 2001+Ap1:2016-06
PN-ISO 6332:2001+Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 8288:2002, metoda A
PN-ISO 9297:1994
PN-ISO 9964-3:1994
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Procedury badawcze
Procedury opracowane przez laboratorium
Procedury opracowane przez laboratorium Normy
Schemat White’a-Kauffmanna-Le Minora, 2007 ISO/TR 6579-3:2014
Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)
Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)
Załącznik nr 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)