{"lab":{"_id":"69ad52a3de79e566650fb312","accr_number":"AB 601","country":"PL","accr_body":"PCA","address":"W KRAKOWIE, ul. Prądnicka 76, 31-202 Kraków","categories":["water","food","microbiology","materials","pharma"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":179,"name":"WOJEWÓDZKA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_601.pdf"],"scope_summary":"","search_text":"wojewódzka stacja sanitarno-epidemiologiczna w krakowie, ul. prądnicka 76, 31-202 kraków materials food pharma other petro metrology water microbiology electronics automotive environment","status":"active","updated_at":"2026-03-08T14:51:29.980Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-08-17T20:58:11.602Z","location":{"type":"Point","coordinates":[19.945,50.0647]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20601,podmiot.html","fields_of_testing":[{"codes":"C/12; C/21; C/22; C/28; C/29; C/42","pl":"Badania chemiczne ceramiki i szkła, wyrobów z tworzyw sztucznych, żywności, wody, wody do spożycia przez ludzi, kosmetyków","en":"Chemical tests of glass and ceramics, plastic products, food, water, drinking water, cosmetics"},{"codes":"G/33","pl":"Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki szkodliwe – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful factors – electromagnetic field)"},{"codes":"K/3; K/22; K/28; K/29; K/42; K/57","pl":"Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, żywności, wody, wody do spożycia przez ludzi, kosmetyków, obiektów z obszaru produkcji żywności","en":"Microbiological tests of biological items and materials for testing, food, water, drinking water, cosmetics, objects from food production area"},{"codes":"N/14; N/28; N/29","pl":"Badania właściwości fizycznych wyposażenia medycznego - urządzenia radiologiczne, wody, wody do spożycia przez ludzi","en":"Tests of physical properties of medical equipment, water, drinking water"},{"codes":"O/1; O/22; O/28; O/29; O/55","pl":"Badania radiochemiczne i promieniowania - w tym nuklearne produktów rolnych, żywności, wody, wody do spożycia przez ludzi, paszy","en":"Radiochemical tests and tests of radiation – including nuclear radiation of agricultural products, food, water, drinking water, animal feedstuffs"}],"issue":{"no":"25","date":"22.04.2026"},"parse_date":"2026-08-17T20:58:11.602Z","parse_source":"agent-claude-code","map_coord":[50.087156,19.937902],"map_geo":"nominatim-street","lab_locations":[{"name":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","address":"ul. Prądnicka 76, 31-202 Kraków","city":"Kraków","postal":"31-202"},{"name":"ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","address":"ul. Prądnicka 76, 31-202 Kraków","city":"Kraków","postal":"31-202"},{"name":"ODDZIAŁ LABORATORYJNY BADANIA WODY","address":"ul. Prądnicka 76, 31-202 Kraków","city":"Kraków","postal":"31-202"},{"name":"Dział Laboratoryjny – obszar higieny radiacyjnej","address":"ul. Prądnicka 76, 31-202 Kraków","city":"Kraków","postal":"31-202"},{"name":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","address":"ul. Prądnicka 76, 31-202 Kraków","city":"Kraków","postal":"31-202"},{"name":"Oddział Laboratoryjny w Tarnowie","address":"ul. Ignacego Mościckiego 10; 33-100 Tarnów","city":"Tarnów","postal":"33-100"},{"name":"ODDZIAŁ LABORATORYJNY w WADOWICACH","address":"ul. Teatralna 2, 34-100 Wadowice","city":"Wadowice","postal":"34-100"}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/8/17/293fc70cd84443c82d41983e34388240/AB%20601.pdf","has_en":true,"category_counts":{"water":112,"food":46,"microbiology":36,"other":15,"materials":12,"pharma":6,"environment":4,"petro":1},"category_scores":{"water":54.07,"food":9.12,"microbiology":5.59,"other":0.97,"materials":0.62,"pharma":0.16,"environment":0.07,"petro":0},"has_zh":true},"methods":[{"_id":"6a8375e3af14b9c0e7b1f556","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość metali i innych pierwiastków","parameters":[],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali i innych pierwiastków\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"Procedury opracowane przez laboratorium Normy","norm_bases":["Procedury opracowane przez laboratorium Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość metali i innych pierwiastków\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) Procedury opracowane przez laboratorium Normy Zywnosc E Zawartosc metali i innych pierwiastkow\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) Procedury opracowane przez laboratorium Normy","categories":["materials","food"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of metals and other elements","search_en":"Food E Content of metals and other elements Flame atomic absorption spectrometry (FAAS) Procedury opracowane przez laboratorium Normy","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Food E","search_zh":"食品 E 火焰原子吸收光谱法（FAAS） Procedury opracowane przez laboratorium Normy","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"食品 E"},{"_id":"6a8375e3af14b9c0e7b1f557","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość metali i innych pierwiastków","parameters":[],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HG AAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HG AAS)"],"computed":[],"activity":"Zawartość metali i innych pierwiastków\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HG AAS)","reference":"Procedury opracowane przez laboratorium Normy","norm_bases":["Procedury opracowane przez laboratorium Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość metali i innych pierwiastków\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HG AAS) Procedury opracowane przez laboratorium Normy Zywnosc E Zawartosc metali i innych pierwiastkow\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HG AAS) Procedury opracowane przez laboratorium Normy","categories":["materials","food"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of metals and other elements","search_en":"Food E Content of metals and other elements Hydride generation atomic absorption spectrometry (HG AAS) Procedury opracowane przez laboratorium Normy","technique_en":"Hydride generation atomic absorption spectrometry (HG AAS)","test_object_en":"Food E","search_zh":"食品 E Procedury opracowane przez laboratorium Normy","test_object_zh":"食品 E"},{"_id":"6a8375e3af14b9c0e7b1f558","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość rtęci","parameters":[],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CV AAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CV AAS)"],"computed":[],"activity":"Zawartość rtęci\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CV AAS)","reference":"PB-LZ/LI-03","norm_bases":["PB-LZ/LI-03"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość rtęci\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CV AAS) PB-LZ/LI-03 Zywnosc E Zawartosc rteci\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CV AAS) PB-LZ/LI-03","categories":["food"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mercury content","search_en":"Food E Mercury content PB-LZ/LI-03","test_object_en":"Food E","methodology_zh":"汞含量","search_zh":"食品 E 汞含量 PB-LZ/LI-03","test_object_zh":"食品 E"},{"_id":"6a8375e3af14b9c0e7b1f559","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość metali i innych pierwiastków","parameters":[],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ET AAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ET AAS)"],"computed":[],"activity":"Zawartość metali i innych pierwiastków\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ET AAS)","reference":"Procedury opracowane przez laboratorium Normy","norm_bases":["Procedury opracowane przez laboratorium Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość metali i innych pierwiastków\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ET AAS) Procedury opracowane przez laboratorium Normy Zywnosc E Zawartosc metali i innych pierwiastkow\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ET AAS) Procedury opracowane przez laboratorium Normy","categories":["materials","food"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Content of metals and other elements","search_en":"Food E Content of metals and other elements Electrothermal atomization atomic absorption spectrometry (ET AAS) Procedury opracowane przez laboratorium Normy","technique_en":"Electrothermal atomization atomic absorption spectrometry (ET AAS)","test_object_en":"Food E","search_zh":"食品 E Procedury opracowane przez laboratorium Normy","test_object_zh":"食品 E"},{"_id":"6a8375e3af14b9c0e7b1f55a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość mikotoksyn","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"Procedury opracowane przez laboratorium Normy","norm_bases":["Procedury opracowane przez laboratorium Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) Procedury opracowane przez laboratorium Normy Zywnosc E Zawartosc mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) Procedury opracowane przez laboratorium Normy","categories":["food"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mycotoxin content","search_en":"Food E Mycotoxin content High-performance liquid chromatography with diode array detection (HPLC-DAD) Procedury opracowane przez laboratorium Normy","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Food E","search_zh":"食品 E 真菌毒素含量 高效液相色谱-二极管阵列检测法（HPLC-DAD） Procedury opracowane przez laboratorium Normy","test_object_zh":"食品 E","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）","methodology_zh":"真菌毒素含量"},{"_id":"6a8375e3af14b9c0e7b1f55b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość mikotoksyn","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Procedury opracowane przez laboratorium Normy","norm_bases":["Procedury opracowane przez laboratorium Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Procedury opracowane przez laboratorium Normy Zywnosc E Zawartosc mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Procedury opracowane przez laboratorium Normy","categories":["food"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Mycotoxin content","search_en":"Food E Mycotoxin content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Procedury opracowane przez laboratorium Normy","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Food E","search_zh":"食品 E 真菌毒素含量 高效液相色谱-荧光检测法（HPLC-FLD） Procedury opracowane przez laboratorium Normy","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"食品 E","methodology_zh":"真菌毒素含量"},{"_id":"6a8375e3af14b9c0e7b1f55c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Procedury opracowane przez laboratorium","norm_bases":["Procedury opracowane przez laboratorium"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Procedury opracowane przez laboratorium Zywnosc E Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Procedury opracowane przez laboratorium","categories":["food"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Polycyclic aromatic hydrocarbons (PAH) content","search_en":"Food E Polycyclic aromatic hydrocarbons (PAH) content High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Procedury opracowane przez laboratorium","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Food E","search_zh":"食品 E 多环芳烃（PAHs）含量 高效液相色谱-荧光检测法（HPLC-FLD） Procedury opracowane przez laboratorium","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"食品 E","methodology_zh":"多环芳烃（PAHs）含量"},{"_id":"6a8375e3af14b9c0e7b1f55d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość barwników","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość barwników\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"Procedury opracowane przez laboratorium","norm_bases":["Procedury opracowane przez laboratorium"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość barwników\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) Procedury opracowane przez laboratorium Zywnosc E Zawartosc barwnikow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) Procedury opracowane przez laboratorium","categories":["food"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colourant content","search_en":"Food E Colourant content High-performance liquid chromatography with diode array detection (HPLC-DAD) Procedury opracowane przez laboratorium","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Food E","search_zh":"食品 E 着色剂含量 高效液相色谱-二极管阵列检测法（HPLC-DAD） Procedury opracowane przez laboratorium","test_object_zh":"食品 E","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）","methodology_zh":"着色剂含量"},{"_id":"6a8375e3af14b9c0e7b1f55e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość środków słodzących","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość środków słodzących\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość środków słodzących\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) Normy Zywnosc E Zawartosc srodkow slodzacych\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) Normy","categories":["food"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Food E High-performance liquid chromatography with diode array detection (HPLC-DAD) Normy","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Food E","search_zh":"食品 E 高效液相色谱-二极管阵列检测法（HPLC-DAD） Normy","test_object_zh":"食品 E","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）"},{"_id":"6a8375e3af14b9c0e7b1f55f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość konserwantów","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość konserwantów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość konserwantów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) Normy Zywnosc E Zawartosc konserwantow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) Normy","categories":["food"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Preservative content","search_en":"Food E Preservative content High-performance liquid chromatography with diode array detection (HPLC-DAD) Normy","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Food E","search_zh":"食品 E 高效液相色谱-二极管阵列检测法（HPLC-DAD） Normy","test_object_zh":"食品 E","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）"},{"_id":"6a8375e3af14b9c0e7b1f560","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość kofeiny","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość kofeiny\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość kofeiny\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) Normy Zywnosc E Zawartosc kofeiny\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) Normy","categories":["food"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Caffeine content","search_en":"Food E Caffeine content High-performance liquid chromatography with diode array detection (HPLC-DAD) Normy","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Food E","search_zh":"食品 E 咖啡因含量 高效液相色谱-二极管阵列检测法（HPLC-DAD） Normy","test_object_zh":"食品 E","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）","methodology_zh":"咖啡因含量"},{"_id":"6a8375e3af14b9c0e7b1f561","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość witamin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"Procedury opracowane przez laboratorium","norm_bases":["Procedury opracowane przez laboratorium"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) Procedury opracowane przez laboratorium Zywnosc E Zawartosc witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) Procedury opracowane przez laboratorium","categories":["food"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vitamin content","search_en":"Food E Vitamin content High-performance liquid chromatography with diode array detection (HPLC-DAD) Procedury opracowane przez laboratorium","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Food E","search_zh":"食品 E 维生素含量 高效液相色谱-二极管阵列检测法（HPLC-DAD） Procedury opracowane przez laboratorium","test_object_zh":"食品 E","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）","methodology_zh":"维生素含量"},{"_id":"6a8375e3af14b9c0e7b1f562","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość kwasów tłuszczowych","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość kwasów tłuszczowych\nMetoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID)","reference":"PB-LI-26","norm_bases":["PB-LI-26"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość kwasów tłuszczowych\nMetoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID) PB-LI-26 Zywnosc E Zawartosc kwasow tluszczowych\nMetoda chromatografii gazowej z detekcja plomieniowo- jonizacyjna (GC-FID) PB-LI-26","categories":["food"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fatty acid content","search_en":"Food E Fatty acid content Gas chromatography with flame ionization detection (GC-FID) PB-LI-26","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Food E","search_zh":"食品 E 脂肪酸含量 气相色谱-火焰离子化检测法（GC-FID） PB-LI-26","test_object_zh":"食品 E","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","methodology_zh":"脂肪酸含量"},{"_id":"6a8375e3af14b9c0e7b1f563","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Wyroby ceramiczne i powierzchnie krzemianowe wyrobów innych niż ceramiczne przeznaczone do kontaktu z żywnością","methodology":"Migracja metali: ołowiu i kadmu","parameters":[{"name":"Ołów"},{"name":"Zakres","range":"(0,2 -100,0) mg/dm3"},{"name":"Zakres","range":"(0,02 - 10,0) mg/dm2"},{"name":"Zakres","range":"(0,02 – 10,0) mg/obrzeże"},{"name":"Kadm"},{"name":"Zakres","range":"(0,02 - 5,0) mg/dm3"},{"name":"Zakres","range":"(0,002 - 0,5) mg/dm2"},{"name":"Zakres","range":"(0,002 – 0,5) mg/obrzeże"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Migracja metali: ołowiu i kadmu\nZakres:\nOłów\nZakres (0,2 -100,0) mg/dm3\nZakres (0,02 - 10,0) mg/dm2\nZakres (0,02 – 10,0) mg/obrzeże\nKadm\nZakres (0,02 - 5,0) mg/dm3\nZakres (0,002 - 0,5) mg/dm2\nZakres (0,002 – 0,5) mg/obrzeże\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1388-1:2000+Ap1:2002 | PN-EN 1388-2:2000","norm_bases":["PN-EN 1388-1:2000+Ap1:2002","PN-EN 1388-2:2000"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby ceramiczne i powierzchnie krzemianowe wyrobów innych niż ceramiczne przeznaczone do kontaktu z żywnością Migracja metali: ołowiu i kadmu\nZakres:\nOłów\nZakres (0,2 -100,0) mg/dm3\nZakres (0,02 - 10,0) mg/dm2\nZakres (0,02 – 10,0) mg/obrzeże\nKadm\nZakres (0,02 - 5,0) mg/dm3\nZakres (0,002 - 0,5) mg/dm2\nZakres (0,002 – 0,5) mg/obrzeże\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1388-1:2000+Ap1:2002 | PN-EN 1388-2:2000 Wyroby ceramiczne i powierzchnie krzemianowe wyrobow innych niz ceramiczne przeznaczone do kontaktu z zywnoscia Migracja metali: olowiu i kadmu\nZakres:\nOlow\nZakres (0,2 -100,0) mg/dm3\nZakres (0,02 - 10,0) mg/dm2\nZakres (0,02 – 10,0) mg/obrzeze\nKadm\nZakres (0,02 - 5,0) mg/dm3\nZakres (0,002 - 0,5) mg/dm2\nZakres (0,002 – 0,5) mg/obrzeze\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1388-1:2000+Ap1:2002 | PN-EN 1388-2:2000","categories":["materials","food"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Lead"},{"name":"Range","range":"(0,2 -100,0) mg/dm3"},{"name":"Range","range":"(0,02 - 10,0) mg/dm2"},{"name":"Range","range":"(0,02 – 10,0) mg/obrzeże"},{"name":"Cadmium"},{"name":"Range","range":"(0,02 - 5,0) mg/dm3"},{"name":"Range","range":"(0,002 - 0,5) mg/dm2"},{"name":"Range","range":"(0,002 – 0,5) mg/obrzeże"}],"search_en":"Ceramic articles and silicate surfaces of non-ceramic articles intended to come into contact with food Flame atomic absorption spectrometry (FAAS) Lead Range Range Range Cadmium Range Range Range PN-EN 1388-1:2000+Ap1:2002 | PN-EN 1388-2:2000","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Ceramic articles and silicate surfaces of non-ceramic articles intended to come into contact with food","parameters_zh":[{"name":"铅"},{"name":"范围","range":"(0,2 -100,0) mg/dm3"},{"name":"范围","range":"(0,02 - 10,0) mg/dm2"},{"name":"范围","range":"(0,02 – 10,0) mg/obrzeże"},{"name":"镉"},{"name":"范围","range":"(0,02 - 5,0) mg/dm3"},{"name":"范围","range":"(0,002 - 0,5) mg/dm2"},{"name":"范围","range":"(0,002 – 0,5) mg/obrzeże"}],"search_zh":"拟与食品接触的陶瓷制品及非陶瓷制品的硅酸盐表面 火焰原子吸收光谱法（FAAS） 铅 范围 范围 范围 镉 范围 范围 范围 PN-EN 1388-1:2000+Ap1:2002 | PN-EN 1388-2:2000","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"拟与食品接触的陶瓷制品及非陶瓷制品的硅酸盐表面"},{"_id":"6a8375e3af14b9c0e7b1f564","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kosmetyki – pasty do zębów","methodology":"Zawartość fluoru","parameters":[{"name":"Zakres","range":"(0,03 - 0,23) %"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość fluoru\nZakres (0,03 - 0,23) %\nMetoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID)","reference":"PB-LI-31 wydanie nr 6 z dnia 01.12.2025 r.","norm_bases":["PB-LI-31 wydanie nr 6 z dnia 01.12.2025 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki – pasty do zębów Zawartość fluoru\nZakres (0,03 - 0,23) %\nMetoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID) PB-LI-31 wydanie nr 6 z dnia 01.12.2025 r. Kosmetyki – pasty do zebow Zawartosc fluoru\nZakres (0,03 - 0,23) %\nMetoda chromatografii gazowej z detekcja plomieniowo- jonizacyjna (GC-FID) PB-LI-31 wydanie nr 6 z dnia 01.12.2025 r.","categories":["pharma"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fluorine content","parameters_en":[{"name":"Range","range":"(0,03 - 0,23) %"}],"search_en":"Cosmetics – toothpastes Fluorine content Gas chromatography with flame ionization detection (GC-FID) Range PB-LI-31 wydanie nr 6 z dnia 01.12.2025 r.","technique_en":"Gas chromatography with flame ionization detection (GC-FID)","test_object_en":"Cosmetics – toothpastes","parameters_zh":[{"name":"范围","range":"(0,03 - 0,23) %"}],"search_zh":"氟含量 气相色谱-火焰离子化检测法（GC-FID） 范围 PB-LI-31 wydanie nr 6 z dnia 01.12.2025 r.","methodology_zh":"氟含量","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）"},{"_id":"6a8375e3af14b9c0e7b1f565","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Ryby, owoce morza i ich przetwory","methodology":"Zawartość histaminy","parameters":[{"name":"Zakres","range":"(10 - 450) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość histaminy\nZakres (10 - 450) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"PN-EN ISO 19343:2017-08","norm_bases":["PN-EN ISO 19343:2017-08"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby, owoce morza i ich przetwory Zawartość histaminy\nZakres (10 - 450) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) PN-EN ISO 19343:2017-08 Ryby, owoce morza i ich przetwory Zawartosc histaminy\nZakres (10 - 450) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) PN-EN ISO 19343:2017-08","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Histamine content","parameters_en":[{"name":"Range","range":"(10 - 450) mg/kg"}],"search_en":"Fish, seafood and their products Histamine content High-performance liquid chromatography with diode array detection (HPLC-DAD) Range PN-EN ISO 19343:2017-08","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","test_object_en":"Fish, seafood and their products","parameters_zh":[{"name":"范围","range":"(10 - 450) mg/kg"}],"search_zh":"组胺含量 高效液相色谱-二极管阵列检测法（HPLC-DAD） 范围 PN-EN ISO 19343:2017-08","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）","methodology_zh":"组胺含量"},{"_id":"6a8375e3af14b9c0e7b1f566","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Wyroby przeznaczone do kontaktu z żywnością wykonane z poliamidu","methodology":"Migracja pierwszorzędowych amin aromatycznych (PAAs) do płynu modelowego 3% kwasu octowego","parameters":[{"name":"Zakres","range":"2,6-toluenodiamina (2,6-TDA)"},{"name":"Zakres","range":"(0,002 - 0,64) mg/kg"},{"name":"2,4-toluenodiamina","range":"(2,4-TDA)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"1,5-diaminonaftalen","range":"(1,5-DAN)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"anilina (ANL)","range":"(0,002 - 0,64) mg/kg"},{"name":"4,4ꞌ-oksydianilina","range":"(4,4-DPE)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"4,4ꞌ-diaminodifenylometan","range":"(4,4-MDA)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"3,3ꞌ-dimetylobenzydyna","range":"(3,3-DMB)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"1,3-fenylenodiamina","range":"(0,002 - 0,64) mg/kg"},{"name":"Suma migracji PAAs (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Migracja pierwszorzędowych amin aromatycznych (PAAs) do płynu modelowego 3% kwasu octowego\nZakres:\nZakres 2,6-toluenodiamina (2,6-TDA)\nZakres (0,002 - 0,64) mg/kg\n2,4-toluenodiamina (2,4-TDA)\n(0,002 - 0,64) mg/kg\n1,5-diaminonaftalen (1,5-DAN)\n(0,002 - 0,64) mg/kg\nanilina (ANL) (0,002 - 0,64) mg/kg\n4,4ꞌ-oksydianilina (4,4-DPE)\n(0,002 - 0,64) mg/kg\n4,4ꞌ-diaminodifenylometan (4,4-MDA)\n(0,002 - 0,64) mg/kg\n3,3ꞌ-dimetylobenzydyna (3,3-DMB)\n(0,002 - 0,64) mg/kg\n1,3-fenylenodiamina (0,002 - 0,64) mg/kg\nSuma migracji PAAs (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"PB-LZ/LI-8 wydanie nr 7 z dnia 21.11.2025 r.","norm_bases":["PB-LZ/LI-8 wydanie nr 7 z dnia 21.11.2025 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby przeznaczone do kontaktu z żywnością wykonane z poliamidu Migracja pierwszorzędowych amin aromatycznych (PAAs) do płynu modelowego 3% kwasu octowego\nZakres:\nZakres 2,6-toluenodiamina (2,6-TDA)\nZakres (0,002 - 0,64) mg/kg\n2,4-toluenodiamina (2,4-TDA)\n(0,002 - 0,64) mg/kg\n1,5-diaminonaftalen (1,5-DAN)\n(0,002 - 0,64) mg/kg\nanilina (ANL) (0,002 - 0,64) mg/kg\n4,4ꞌ-oksydianilina (4,4-DPE)\n(0,002 - 0,64) mg/kg\n4,4ꞌ-diaminodifenylometan (4,4-MDA)\n(0,002 - 0,64) mg/kg\n3,3ꞌ-dimetylobenzydyna (3,3-DMB)\n(0,002 - 0,64) mg/kg\n1,3-fenylenodiamina (0,002 - 0,64) mg/kg\nSuma migracji PAAs (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) PB-LZ/LI-8 wydanie nr 7 z dnia 21.11.2025 r. Wyroby przeznaczone do kontaktu z zywnoscia wykonane z poliamidu Migracja pierwszorzedowych amin aromatycznych (PAAs) do plynu modelowego 3% kwasu octowego\nZakres:\nZakres 2,6-toluenodiamina (2,6-TDA)\nZakres (0,002 - 0,64) mg/kg\n2,4-toluenodiamina (2,4-TDA)\n(0,002 - 0,64) mg/kg\n1,5-diaminonaftalen (1,5-DAN)\n(0,002 - 0,64) mg/kg\nanilina (ANL) (0,002 - 0,64) mg/kg\n4,4ꞌ-oksydianilina (4,4-DPE)\n(0,002 - 0,64) mg/kg\n4,4ꞌ-diaminodifenylometan (4,4-MDA)\n(0,002 - 0,64) mg/kg\n3,3ꞌ-dimetylobenzydyna (3,3-DMB)\n(0,002 - 0,64) mg/kg\n1,3-fenylenodiamina (0,002 - 0,64) mg/kg\nSuma migracji PAAs (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) PB-LZ/LI-8 wydanie nr 7 z dnia 21.11.2025 r.","categories":["food"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"2,6-toluenodiamina (2,6-TDA)"},{"name":"Range","range":"(0,002 - 0,64) mg/kg"},{"name":"2,4-toluenediamine","range":"(2,4-TDA)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"1,5-diaminonaphthalene","range":"(1,5-DAN)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"aniline (ANL)","range":"(0,002 - 0,64) mg/kg"},{"name":"4,4ꞌ-oxydianiline","range":"(4,4-DPE)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"4,4ꞌ-diaminodiphenylmethane","range":"(4,4-MDA)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"3,3ꞌ-dimethylbenzidine","range":"(3,3-DMB)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"1,3-phenylenediamine","range":"(0,002 - 0,64) mg/kg"},{"name":"Sum of PAAs migration (calculated)"}],"search_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD) Range Range 2,4-toluenediamine (0,002 - 0,64) mg/kg 1,5-diaminonaphthalene (0,002 - 0,64) mg/kg aniline (ANL) 4,4ꞌ-oxydianiline (0,002 - 0,64) mg/kg 4,4ꞌ-diaminodiphenylmethane (0,002 - 0,64) mg/kg 3,3ꞌ-dimethylbenzidine (0,002 - 0,64) mg/kg 1,3-phenylenediamine Sum of PAAs migration (calculated) PB-LZ/LI-8 wydanie nr 7 z dnia 21.11.2025 r.","technique_en":"High-performance liquid chromatography with diode array detection (HPLC-DAD)","parameters_zh":[{"name":"范围","range":"2,6-toluenodiamina (2,6-TDA)"},{"name":"范围","range":"(0,002 - 0,64) mg/kg"},{"name":"2,4-toluenodiamina","range":"(2,4-TDA)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"1,5-diaminonaftalen","range":"(1,5-DAN)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"anilina (ANL)","range":"(0,002 - 0,64) mg/kg"},{"name":"4,4ꞌ-oksydianilina","range":"(4,4-DPE)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"4,4ꞌ-diaminodifenylometan","range":"(4,4-MDA)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"3,3ꞌ-dimetylobenzydyna","range":"(3,3-DMB)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"1,3-fenylenodiamina","range":"(0,002 - 0,64) mg/kg"},{"name":"Suma migracji PAAs (z obliczeń)"}],"search_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD） 范围 范围 PB-LZ/LI-8 wydanie nr 7 z dnia 21.11.2025 r.","technique_zh":"高效液相色谱-二极管阵列检测法（HPLC-DAD）"},{"_id":"6a8375e3af14b9c0e7b1f567","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Wyroby przeznaczone do kontaktu z żywnością","methodology":"Migracja bisfenolu A do płynów modelowych - 3% kwas octowy, 10% etanol, 20% etanol, 50% etanol","parameters":[{"name":"Zakres","range":"(0,002 - 0,5) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Migracja bisfenolu A do płynów modelowych - 3% kwas octowy, 10% etanol, 20% etanol, 50% etanol\nZakres (0,002 - 0,5) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-LZ/LI-12 wydanie nr 2 z dnia 21.11.2025 r.","norm_bases":["PB-LZ/LI-12 wydanie nr 2 z dnia 21.11.2025 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby przeznaczone do kontaktu z żywnością Migracja bisfenolu A do płynów modelowych - 3% kwas octowy, 10% etanol, 20% etanol, 50% etanol\nZakres (0,002 - 0,5) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-LZ/LI-12 wydanie nr 2 z dnia 21.11.2025 r. Wyroby przeznaczone do kontaktu z zywnoscia Migracja bisfenolu A do plynow modelowych - 3% kwas octowy, 10% etanol, 20% etanol, 50% etanol\nZakres (0,002 - 0,5) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-LZ/LI-12 wydanie nr 2 z dnia 21.11.2025 r.","categories":["food"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Migration of bisphenol A into food simulants - 3% acetic acid, 10% ethanol, 20% ethanol, 50% ethanol","parameters_en":[{"name":"Range","range":"(0,002 - 0,5) mg/kg"}],"search_en":"Migration of bisphenol A into food simulants - 3% acetic acid, 10% ethanol, 20% ethanol, 50% ethanol High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range PB-LZ/LI-12 wydanie nr 2 z dnia 21.11.2025 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","parameters_zh":[{"name":"范围","range":"(0,002 - 0,5) mg/kg"}],"search_zh":"高效液相色谱-荧光检测法（HPLC-FLD） 范围 PB-LZ/LI-12 wydanie nr 2 z dnia 21.11.2025 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）"},{"_id":"6a8375e3af14b9c0e7b1f568","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość fosforu całkowitego i dodanego","parameters":[{"name":"Fosfor całkowity"},{"name":"Zakres","range":"(0,2 - 2,0) g/100 g (jako P2O5)"},{"name":"Fosfor dodany (z obliczeń)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu całkowitego i dodanego\nZakres:\nFosfor całkowity\nZakres (0,2 - 2,0) g/100 g (jako P2O5)\nFosfor dodany (z obliczeń)\nMetoda spektrofotometryczna","reference":"PN-ISO 13730:1999+Ap1:2004","norm_bases":["PN-ISO 13730:1999+Ap1:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość fosforu całkowitego i dodanego\nZakres:\nFosfor całkowity\nZakres (0,2 - 2,0) g/100 g (jako P2O5)\nFosfor dodany (z obliczeń)\nMetoda spektrofotometryczna PN-ISO 13730:1999+Ap1:2004 Mieso i przetwory miesne Zawartosc fosforu calkowitego i dodanego\nZakres:\nFosfor calkowity\nZakres (0,2 - 2,0) g/100 g (jako P2O5)\nFosfor dodany (z obliczen)\nMetoda spektrofotometryczna PN-ISO 13730:1999+Ap1:2004","categories":["food"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total and added phosphorus content","parameters_en":[{"name":"Total phosphorus"},{"name":"Range","range":"(0,2 - 2,0) g/100 g (jako P2O5)"},{"name":"Added phosphorus (calculated)"}],"search_en":"Meat and meat products Total and added phosphorus content Spectrophotometric method Total phosphorus Range Added phosphorus (calculated) PN-ISO 13730:1999+Ap1:2004","technique_en":"Spectrophotometric method","test_object_en":"Meat and meat products","parameters_zh":[{"name":"Fosfor całkowity"},{"name":"范围","range":"(0,2 - 2,0) g/100 g (jako P2O5)"},{"name":"添加磷（由计算得出）"}],"search_zh":"肉与肉制品 分光光度法 范围 添加磷（由计算得出） PN-ISO 13730:1999+Ap1:2004","technique_zh":"分光光度法","test_object_zh":"肉与肉制品"},{"_id":"6a8375e3af14b9c0e7b1f569","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci","methodology":"Zawartość tłuszczu","parameters":[{"name":"Zakres","range":"(0,02 -24,0) %"}],"technique":"Metoda ekstrakcyjno-wagowa","techniques":["Metoda ekstrakcyjno-wagowa"],"computed":[],"activity":"Zawartość tłuszczu\nZakres (0,02 -24,0) %\nMetoda ekstrakcyjno-wagowa","reference":"PB-LZ-05 wydanie nr 5 z dnia 21.11.2025 r.","norm_bases":["PB-LZ-05 wydanie nr 5 z dnia 21.11.2025 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci Zawartość tłuszczu\nZakres (0,02 -24,0) %\nMetoda ekstrakcyjno-wagowa PB-LZ-05 wydanie nr 5 z dnia 21.11.2025 r. Mieso i produkty miesne, Wyroby garmazeryjne, Koncentraty spozywcze, Produkty zbozowe, Zywnosc dla niemowlat i malych dzieci Zawartosc tluszczu\nZakres (0,02 -24,0) %\nMetoda ekstrakcyjno-wagowa PB-LZ-05 wydanie nr 5 z dnia 21.11.2025 r.","categories":["food"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Fat content","parameters_en":[{"name":"Range","range":"(0,02 -24,0) %"}],"search_en":"Fat content Extraction-gravimetric method Range PB-LZ-05 wydanie nr 5 z dnia 21.11.2025 r.","technique_en":"Extraction-gravimetric method","methodology_zh":"脂肪含量","parameters_zh":[{"name":"范围","range":"(0,02 -24,0) %"}],"search_zh":"脂肪含量 萃取-重量法 范围 PB-LZ-05 wydanie nr 5 z dnia 21.11.2025 r.","technique_zh":"萃取-重量法"},{"_id":"6a8375e3af14b9c0e7b1f56a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,8 -96,7) %"},{"name":"Zawartość suchej masy"},{"name":"Zakres","range":"(3,3 -99,2) %"}],"technique":"Metoda wagowa; Metoda wagowa","techniques":["Metoda wagowa","Metoda wagowa"],"computed":[],"activity":"Zawartość wody\nZakres:\nZakres (0,8 -96,7) %\nZawartość suchej masy\nZakres (3,3 -99,2) %\nMetoda wagowa; Metoda wagowa","reference":"PB-LZ-01 wydanie nr 2 z dnia 08.01.2026 r.","norm_bases":["PB-LZ-01 wydanie nr 2 z dnia 08.01.2026 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci Zawartość wody\nZakres:\nZakres (0,8 -96,7) %\nZawartość suchej masy\nZakres (3,3 -99,2) %\nMetoda wagowa; Metoda wagowa PB-LZ-01 wydanie nr 2 z dnia 08.01.2026 r. Mieso i produkty miesne, Wyroby garmazeryjne, Koncentraty spozywcze, Produkty zbozowe, Zywnosc dla niemowlat i malych dzieci Zawartosc wody\nZakres:\nZakres (0,8 -96,7) %\nZawartosc suchej masy\nZakres (3,3 -99,2) %\nMetoda wagowa; Metoda wagowa PB-LZ-01 wydanie nr 2 z dnia 08.01.2026 r.","categories":["food","water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Water content","parameters_en":[{"name":"Range","range":"(0,8 -96,7) %"},{"name":"Dry matter content"},{"name":"Range","range":"(3,3 -99,2) %"}],"search_en":"Water content Gravimetric method; Gravimetric method Range Dry matter content Range PB-LZ-01 wydanie nr 2 z dnia 08.01.2026 r.","technique_en":"Gravimetric method; Gravimetric method","methodology_zh":"水分含量","parameters_zh":[{"name":"范围","range":"(0,8 -96,7) %"},{"name":"干物质含量"},{"name":"范围","range":"(3,3 -99,2) %"}],"search_zh":"水分含量 重量法；重量法 范围 干物质含量 范围 PB-LZ-01 wydanie nr 2 z dnia 08.01.2026 r.","technique_zh":"重量法；重量法"},{"_id":"6a8375e3af14b9c0e7b1f56b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci","methodology":"Zawartość popiołu ogólnego","parameters":[{"name":"Zakres","range":"(0,1 -11,8) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu ogólnego\nZakres (0,1 -11,8) %\nMetoda wagowa","reference":"PB-LZ-02 wydanie nr 2 z dnia 08.01.2026 r.","norm_bases":["PB-LZ-02 wydanie nr 2 z dnia 08.01.2026 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci Zawartość popiołu ogólnego\nZakres (0,1 -11,8) %\nMetoda wagowa PB-LZ-02 wydanie nr 2 z dnia 08.01.2026 r. Mieso i produkty miesne, Wyroby garmazeryjne, Koncentraty spozywcze, Produkty zbozowe, Zywnosc dla niemowlat i malych dzieci Zawartosc popiolu ogolnego\nZakres (0,1 -11,8) %\nMetoda wagowa PB-LZ-02 wydanie nr 2 z dnia 08.01.2026 r.","categories":["food"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total ash content","parameters_en":[{"name":"Range","range":"(0,1 -11,8) %"}],"search_en":"Total ash content Gravimetric method Range PB-LZ-02 wydanie nr 2 z dnia 08.01.2026 r.","technique_en":"Gravimetric method","parameters_zh":[{"name":"范围","range":"(0,1 -11,8) %"}],"search_zh":"总灰分含量 重量法 范围 PB-LZ-02 wydanie nr 2 z dnia 08.01.2026 r.","technique_zh":"重量法","methodology_zh":"总灰分含量"},{"_id":"6a8375e3af14b9c0e7b1f56c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna z zastosowaniem torebki, przez całkowite zanurzenie, z zastosowaniem komory pomiarowej, przez napełnienie wyrobu do płynów modelowych:","parameters":[{"name":"Woda","range":"(2,0 - 200,0) mg/dm2"},{"name":"Zakres","range":"(12,0 - 400,0) mg/kg"},{"name":"3% kwas octowy","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"10% etanol","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"20% etanol","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"50% etanol","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"95% etanol","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"Izooktan","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna z zastosowaniem torebki, przez całkowite zanurzenie, z zastosowaniem komory pomiarowej, przez napełnienie wyrobu do płynów modelowych:\nZakres:\nWoda (2,0 - 200,0) mg/dm2\nZakres (12,0 - 400,0) mg/kg\n3% kwas octowy (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n10% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n20% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n50% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n95% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\nIzooktan (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna z zastosowaniem torebki, przez całkowite zanurzenie, z zastosowaniem komory pomiarowej, przez napełnienie wyrobu do płynów modelowych:\nZakres:\nWoda (2,0 - 200,0) mg/dm2\nZakres (12,0 - 400,0) mg/kg\n3% kwas octowy (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n10% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n20% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n50% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n95% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\nIzooktan (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna z zastosowaniem torebki, przez calkowite zanurzenie, z zastosowaniem komory pomiarowej, przez napelnienie wyrobu do plynow modelowych:\nZakres:\nWoda (2,0 - 200,0) mg/dm2\nZakres (12,0 - 400,0) mg/kg\n3% kwas octowy (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n10% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n20% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n50% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n95% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\nIzooktan (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","water","food"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Overall migration by the pouch method, by total immersion, using a test cell, by filling the article, into food simulants:","parameters_en":[{"name":"Water","range":"(2,0 - 200,0) mg/dm2"},{"name":"Range","range":"(12,0 - 400,0) mg/kg"},{"name":"3% acetic acid","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"10% ethanol","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"20% ethanol","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"50% ethanol","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"95% ethanol","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"Isooctane","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"}],"search_en":"Plastic materials and articles intended to come into contact with food Overall migration by the pouch method, by total immersion, using a test cell, by filling the article, into food simulants: Gravimetric method Water Range 3% acetic acid (12,0 - 400,0) mg/kg 10% ethanol (12,0 - 400,0) mg/kg 20% ethanol (12,0 - 400,0) mg/kg 50% ethanol (12,0 - 400,0) mg/kg 95% ethanol (12,0 - 400,0) mg/kg Isooctane (12,0 - 400,0) mg/kg PN-EN 1186-3:2023-01","technique_en":"Gravimetric method","test_object_en":"Plastic materials and articles intended to come into contact with food","parameters_zh":[{"name":"水","range":"(2,0 - 200,0) mg/dm2"},{"name":"范围","range":"(12,0 - 400,0) mg/kg"},{"name":"3% 乙酸","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"10% 乙醇","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"20% 乙醇","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"50% 乙醇","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"95% 乙醇","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"异辛烷","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"}],"search_zh":"拟与食品接触的塑料材料及制品 重量法 水 范围 3% 乙酸 10% 乙醇 20% 乙醇 50% 乙醇 95% 乙醇 异辛烷 PN-EN 1186-3:2023-01","technique_zh":"重量法","test_object_zh":"拟与食品接触的塑料材料及制品"},{"_id":"6a8375e3af14b9c0e7b1f56d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Tłoczywa melaminowo- formaldehydowe","methodology":"Migracja specyficzna formaldehydu do płynu modelowego 3% kwasu octowego","parameters":[{"name":"Zakres","range":"(3,0 – 30,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Migracja specyficzna formaldehydu do płynu modelowego 3% kwasu octowego\nZakres (3,0 – 30,0) mg/kg\nMetoda spektrofotometryczna","reference":"CN/TS 13130-23:2005","norm_bases":["CN/TS 13130-23:2005"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tłoczywa melaminowo- formaldehydowe Migracja specyficzna formaldehydu do płynu modelowego 3% kwasu octowego\nZakres (3,0 – 30,0) mg/kg\nMetoda spektrofotometryczna CN/TS 13130-23:2005 Tloczywa melaminowo- formaldehydowe Migracja specyficzna formaldehydu do plynu modelowego 3% kwasu octowego\nZakres (3,0 – 30,0) mg/kg\nMetoda spektrofotometryczna CN/TS 13130-23:2005","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Range","range":"(3,0 – 30,0) mg/kg"}],"search_en":"Melamine-formaldehyde moulding compounds Spectrophotometric method Range CN/TS 13130-23:2005","technique_en":"Spectrophotometric method","test_object_en":"Melamine-formaldehyde moulding compounds","parameters_zh":[{"name":"范围","range":"(3,0 – 30,0) mg/kg"}],"search_zh":"分光光度法 范围 CN/TS 13130-23:2005","technique_zh":"分光光度法"},{"_id":"6a8375e3af14b9c0e7b1f56e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość witaminy C","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość witaminy C\nMetoda miareczkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość witaminy C\nMetoda miareczkowa Normy Zywnosc E Zawartosc witaminy C\nMetoda miareczkowa Normy","categories":["food"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Vitamin C content","search_en":"Food E Vitamin C content Titrimetric method Normy","technique_en":"Titrimetric method","test_object_en":"Food E","search_zh":"食品 E 维生素C含量 滴定法 Normy","technique_zh":"滴定法","test_object_zh":"食品 E","methodology_zh":"维生素C含量"},{"_id":"6a8375e3af14b9c0e7b1f56f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Oleje oraz tłuszcze roślinne i zwierzęce E","methodology":"Parametry jełczenia","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Parametry jełczenia\nMetoda miareczkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Oleje oraz tłuszcze roślinne i zwierzęce E Parametry jełczenia\nMetoda miareczkowa Normy Oleje oraz tluszcze roslinne i zwierzece E Parametry jelczenia\nMetoda miareczkowa Normy","categories":["food","petro"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Rancidity parameters","search_en":"Rancidity parameters Titrimetric method Normy","technique_en":"Titrimetric method","search_zh":"滴定法 Normy","technique_zh":"滴定法"},{"_id":"6a8375e3af14b9c0e7b1f570","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość dwutlenku siarki","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość dwutlenku siarki\nMetoda miareczkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość dwutlenku siarki\nMetoda miareczkowa Normy Zywnosc E Zawartosc dwutlenku siarki\nMetoda miareczkowa Normy","categories":["food"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur dioxide content","search_en":"Food E Sulfur dioxide content Titrimetric method Normy","technique_en":"Titrimetric method","test_object_en":"Food E","search_zh":"食品 E 二氧化硫含量 滴定法 Normy","technique_zh":"滴定法","test_object_zh":"食品 E","methodology_zh":"二氧化硫含量"},{"_id":"6a8375e3af14b9c0e7b1f571","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość pierwiastków","parameters":[{"name":"Zawartość związków (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość pierwiastków\nZawartość związków (z obliczeń)\nMetoda miareczkowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość pierwiastków\nZawartość związków (z obliczeń)\nMetoda miareczkowa Procedury badawcze Zywnosc E Zawartosc pierwiastkow\nZawartosc zwiazkow (z obliczen)\nMetoda miareczkowa Procedury badawcze","categories":["food"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Element content","search_en":"Food E Element content Titrimetric method Procedury badawcze","technique_en":"Titrimetric method","test_object_en":"Food E","methodology_zh":"元素含量","search_zh":"食品 E 元素含量 滴定法 Procedury badawcze","technique_zh":"滴定法","test_object_zh":"食品 E"},{"_id":"6a8375e3af14b9c0e7b1f572","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E, Obiekty z obszaru produkcji żywności E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Obiekty z obszaru produkcji żywności E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Zywnosc E, Obiekty z obszaru produkcji zywnosci E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["food","microbiology"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method with biochemical and serological confirmation Normy","technique_en":"Culture method with biochemical and serological confirmation","search_zh":"微生物的检出 培养法结合生化与血清学确认 Normy","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"微生物的检出"},{"_id":"6a8375e3af14b9c0e7b1f573","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E, Kosmetyki E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Kosmetyki E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Zywnosc E, Kosmetyki E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy","categories":["food","microbiology","pharma"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Presence of microorganisms Culture method with biochemical confirmation Normy","technique_en":"Culture method with biochemical confirmation","search_zh":"微生物的检出 培养法结合生化确认 Normy","technique_zh":"培养法结合生化确认","methodology_zh":"微生物的检出"},{"_id":"6a8375e3af14b9c0e7b1f574","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E, Kosmetyki E, Obiekty z obszaru produkcji żywności E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Kosmetyki E, Obiekty z obszaru produkcji żywności E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Zywnosc E, Kosmetyki E, Obiekty z obszaru produkcji zywnosci E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["food","microbiology","pharma"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (pour plate) Normy","technique_en":"Plate method (pour plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（倾注培养） Normy","technique_zh":"平板法（倾注培养）"},{"_id":"6a8375e3af14b9c0e7b1f575","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E, Obiekty z obszaru produkcji żywności E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Obiekty z obszaru produkcji żywności E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Zywnosc E, Obiekty z obszaru produkcji zywnosci E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy","categories":["food","microbiology"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Microorganism count Plate method (spread plate) Normy","technique_en":"Plate method (spread plate)","methodology_zh":"菌落总数","search_zh":"菌落总数 平板法（表面涂布） Normy","technique_zh":"平板法（表面涂布）"},{"_id":"6a8375e3af14b9c0e7b1f576","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(30 - 10000) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (30 - 10000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.","norm_bases":["PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie manganu\nZakres (30 - 10000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r. Woda (w tym woda na plywalni) Stezenie manganu\nZakres (30 - 10000) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(30 - 10000) μg/l"}],"search_en":"Water (including swimming pool water) Manganese concentration Flame atomic absorption spectrometry (FAAS) Range PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water (including swimming pool water)","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(30 - 10000) μg/l"}],"search_zh":"水（含游泳池水） 锰浓度 火焰原子吸收光谱法（FAAS） 范围 PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f577","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie miedzi i cynku","parameters":[{"name":"Miedź","range":"(0,04 - 25) mg/l"},{"name":"Cynk","range":"(0,20 - 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi i cynku\nZakres:\nMiedź (0,04 - 25) mg/l\nCynk (0,20 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002, metoda A","norm_bases":["PN-ISO 8288:2002, metoda A"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie miedzi i cynku\nZakres:\nMiedź (0,04 - 25) mg/l\nCynk (0,20 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002, metoda A Woda (w tym woda na plywalni) Stezenie miedzi i cynku\nZakres:\nMiedz (0,04 - 25) mg/l\nCynk (0,20 - 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002, metoda A","categories":["water","materials"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Copper","range":"(0,04 - 25) mg/l"},{"name":"Zinc","range":"(0,20 - 10) mg/l"}],"search_en":"Water (including swimming pool water) Flame atomic absorption spectrometry (FAAS) Copper Zinc PN-ISO 8288:2002, metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"铜","range":"(0,04 - 25) mg/l"},{"name":"锌","range":"(0,20 - 10) mg/l"}],"search_zh":"水（含游泳池水） 火焰原子吸收光谱法（FAAS） 铜 锌 PN-ISO 8288:2002, metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f578","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie sodu","parameters":[{"name":"Zakres","range":"(2,50 - 500) mg/l"}],"technique":"Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","techniques":["Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)"],"computed":[],"activity":"Stężenie sodu\nZakres (2,50 - 500) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","reference":"PN-ISO 9964-3:1994","norm_bases":["PN-ISO 9964-3:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie sodu\nZakres (2,50 - 500) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES) PN-ISO 9964-3:1994 Woda (w tym woda na plywalni) Stezenie sodu\nZakres (2,50 - 500) mg/l\nMetoda plomieniowej emisyjnej spektrometrii atomowej (FAES) PN-ISO 9964-3:1994","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium concentration","parameters_en":[{"name":"Range","range":"(2,50 - 500) mg/l"}],"search_en":"Water (including swimming pool water) Sodium concentration Flame atomic emission spectrometry (FAES) Range PN-ISO 9964-3:1994","technique_en":"Flame atomic emission spectrometry (FAES)","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"范围","range":"(2,50 - 500) mg/l"}],"search_zh":"水（含游泳池水） 钠浓度 火焰原子发射光谱法（FAES） 范围 PN-ISO 9964-3:1994","methodology_zh":"钠浓度","technique_zh":"火焰原子发射光谱法（FAES）","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f579","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi i rtęci","parameters":[{"name":"Ołów","range":"(1,0 - 100) μg/l"},{"name":"Kadm","range":"(0,50 - 50) μg/l"},{"name":"Nikiel","range":"(1,0 - 100) μg/l"},{"name":"Chrom","range":"(5,0 - 100) μg/l"},{"name":"Glin","range":"(10,0 - 2000) μg/l"},{"name":"Mangan","range":"(5,0 - 100) μg/l"},{"name":"Antymon","range":"(0,50 - 50) μg/l"},{"name":"Arsen","range":"(1,0 - 100) μg/l"},{"name":"Selen","range":"(1,0 - 100) μg/l"},{"name":"Bor","range":"(50 - 5000) μg/l"},{"name":"Srebro","range":"(0,5 - 100) μg/l"},{"name":"Miedź","range":"(5,0 - 2100) μg/l"},{"name":"Rtęć","range":"(0,10 - 5,0) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS)"],"computed":[],"activity":"Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi i rtęci\nZakres:\nOłów (1,0 - 100) μg/l\nKadm (0,50 - 50) μg/l\nNikiel (1,0 - 100) μg/l\nChrom (5,0 - 100) μg/l\nGlin (10,0 - 2000) μg/l\nMangan (5,0 - 100) μg/l\nAntymon (0,50 - 50) μg/l\nArsen (1,0 - 100) μg/l\nSelen (1,0 - 100) μg/l\nBor (50 - 5000) μg/l\nSrebro (0,5 - 100) μg/l\nMiedź (5,0 - 2100) μg/l\nRtęć (0,10 - 5,0) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi i rtęci\nZakres:\nOłów (1,0 - 100) μg/l\nKadm (0,50 - 50) μg/l\nNikiel (1,0 - 100) μg/l\nChrom (5,0 - 100) μg/l\nGlin (10,0 - 2000) μg/l\nMangan (5,0 - 100) μg/l\nAntymon (0,50 - 50) μg/l\nArsen (1,0 - 100) μg/l\nSelen (1,0 - 100) μg/l\nBor (50 - 5000) μg/l\nSrebro (0,5 - 100) μg/l\nMiedź (5,0 - 2100) μg/l\nRtęć (0,10 - 5,0) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS) PN-EN ISO 17294-2:2024-04 Woda (w tym woda na plywalni) Stezenie olowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi i rteci\nZakres:\nOlow (1,0 - 100) μg/l\nKadm (0,50 - 50) μg/l\nNikiel (1,0 - 100) μg/l\nChrom (5,0 - 100) μg/l\nGlin (10,0 - 2000) μg/l\nMangan (5,0 - 100) μg/l\nAntymon (0,50 - 50) μg/l\nArsen (1,0 - 100) μg/l\nSelen (1,0 - 100) μg/l\nBor (50 - 5000) μg/l\nSrebro (0,5 - 100) μg/l\nMiedz (5,0 - 2100) μg/l\nRtec (0,10 - 5,0) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP MS) PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of lead, cadmium, nickel, chromium, aluminium, manganese, antimony, arsenic, selenium, boron, silver, copper and mercury","parameters_en":[{"name":"Lead","range":"(1,0 - 100) μg/l"},{"name":"Cadmium","range":"(0,50 - 50) μg/l"},{"name":"Nickel","range":"(1,0 - 100) μg/l"},{"name":"Chromium","range":"(5,0 - 100) μg/l"},{"name":"Aluminium","range":"(10,0 - 2000) μg/l"},{"name":"Manganese","range":"(5,0 - 100) μg/l"},{"name":"Antimony","range":"(0,50 - 50) μg/l"},{"name":"Arsenic","range":"(1,0 - 100) μg/l"},{"name":"Selenium","range":"(1,0 - 100) μg/l"},{"name":"Boron","range":"(50 - 5000) μg/l"},{"name":"Silver","range":"(0,5 - 100) μg/l"},{"name":"Copper","range":"(5,0 - 2100) μg/l"},{"name":"Mercury","range":"(0,10 - 5,0) μg/l"}],"search_en":"Water (including swimming pool water) Concentration of lead, cadmium, nickel, chromium, aluminium, manganese, antimony, arsenic, selenium, boron, silver, copper and mercury Lead Cadmium Nickel Chromium Aluminium Manganese Antimony Arsenic Selenium Boron Silver Copper Mercury PN-EN ISO 17294-2:2024-04","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"铅","range":"(1,0 - 100) μg/l"},{"name":"镉","range":"(0,50 - 50) μg/l"},{"name":"镍","range":"(1,0 - 100) μg/l"},{"name":"铬","range":"(5,0 - 100) μg/l"},{"name":"铝","range":"(10,0 - 2000) μg/l"},{"name":"锰","range":"(5,0 - 100) μg/l"},{"name":"锑","range":"(0,50 - 50) μg/l"},{"name":"砷","range":"(1,0 - 100) μg/l"},{"name":"硒","range":"(1,0 - 100) μg/l"},{"name":"硼","range":"(50 - 5000) μg/l"},{"name":"银","range":"(0,5 - 100) μg/l"},{"name":"铜","range":"(5,0 - 2100) μg/l"},{"name":"汞","range":"(0,10 - 5,0) μg/l"}],"search_zh":"水（含游泳池水） 铅 镉 镍 铬 铝 锰 锑 砷 硒 硼 银 铜 汞 PN-EN ISO 17294-2:2024-04","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f57a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie łatwolotnych chlorowcopochodnych węglowodorów","parameters":[{"name":"Trichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM):"},{"name":"Zakres","range":"(5,0 - 120) μg/l"},{"name":"Suma THM (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie łatwolotnych chlorowcopochodnych węglowodorów\nZakres:\nTrichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM):\nZakres (5,0 - 120) μg/l\nSuma THM (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002 Rozdział 2","norm_bases":["PN-EN ISO 10301:2002 Rozdział 2"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie łatwolotnych chlorowcopochodnych węglowodorów\nZakres:\nTrichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM):\nZakres (5,0 - 120) μg/l\nSuma THM (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 Rozdział 2 Woda (w tym woda na plywalni) Stezenie latwolotnych chlorowcopochodnych weglowodorow\nZakres:\nTrichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM):\nZakres (5,0 - 120) μg/l\nSuma THM (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002 Rozdzial 2","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Trichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM):"},{"name":"Range","range":"(5,0 - 120) μg/l"},{"name":"Sum of THM (calculated)"}],"search_en":"Water (including swimming pool water) Gas chromatography with electron capture detection (GC-ECD) Range Sum of THM (calculated) PN-EN ISO 10301:2002 Rozdział 2","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"Trichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM):"},{"name":"范围","range":"(5,0 - 120) μg/l"},{"name":"三卤甲烷总量（由计算得出）"}],"search_zh":"水（含游泳池水） 气相色谱-电子捕获检测法（GC-ECD） 范围 三卤甲烷总量（由计算得出） PN-EN ISO 10301:2002 Rozdział 2","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f57b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie anionów","parameters":[{"name":"Chlorki","range":"(1,0 - 1000) mg/l"},{"name":"Azotany","range":"(1,0 - 1000) mg/l"},{"name":"Fluorki","range":"(0,10 - 10) mg/l"},{"name":"Siarczany","range":"(1,0 - 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorki (1,0 - 1000) mg/l\nAzotany (1,0 - 1000) mg/l\nFluorki (0,10 - 10) mg/l\nSiarczany (1,0 - 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie anionów\nZakres:\nChlorki (1,0 - 1000) mg/l\nAzotany (1,0 - 1000) mg/l\nFluorki (0,10 - 10) mg/l\nSiarczany (1,0 - 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Woda (w tym woda na plywalni) Stezenie anionow\nZakres:\nChlorki (1,0 - 1000) mg/l\nAzotany (1,0 - 1000) mg/l\nFluorki (0,10 - 10) mg/l\nSiarczany (1,0 - 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Chlorides","range":"(1,0 - 1000) mg/l"},{"name":"Nitrates","range":"(1,0 - 1000) mg/l"},{"name":"Fluorides","range":"(0,10 - 10) mg/l"},{"name":"Sulfates","range":"(1,0 - 1000) mg/l"}],"search_en":"Water (including swimming pool water) Anion concentrations Ion chromatography with conductometric detection (IC-CD) Chlorides Nitrates Fluorides Sulfates PN-EN ISO 10304-1:2009 +AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water (including swimming pool water)","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氯化物","range":"(1,0 - 1000) mg/l"},{"name":"硝酸盐","range":"(1,0 - 1000) mg/l"},{"name":"氟化物","range":"(0,10 - 10) mg/l"},{"name":"硫酸盐","range":"(1,0 - 1000) mg/l"}],"search_zh":"水（含游泳池水） 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 硝酸盐 氟化物 硫酸盐 PN-EN ISO 10304-1:2009 +AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f57c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(30 - 10000) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (30 - 10000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.","norm_bases":["PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (30 - 10000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r. Woda do spozycia przez ludzi Stezenie manganu\nZakres (30 - 10000) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Manganese concentration","parameters_en":[{"name":"Range","range":"(30 - 10000) μg/l"}],"search_en":"Water intended for human consumption Manganese concentration Flame atomic absorption spectrometry (FAAS) Range PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water intended for human consumption","methodology_zh":"锰浓度","parameters_zh":[{"name":"范围","range":"(30 - 10000) μg/l"}],"search_zh":"生活饮用水 锰浓度 火焰原子吸收光谱法（FAAS） 范围 PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f57d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie miedzi i cynku","parameters":[{"name":"Miedź","range":"(0,04 - 25) mg/l"},{"name":"Cynk","range":"(0,20 - 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi i cynku\nZakres:\nMiedź (0,04 - 25) mg/l\nCynk (0,20 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002, metoda A","norm_bases":["PN-ISO 8288:2002, metoda A"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie miedzi i cynku\nZakres:\nMiedź (0,04 - 25) mg/l\nCynk (0,20 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002, metoda A Woda do spozycia przez ludzi Stezenie miedzi i cynku\nZakres:\nMiedz (0,04 - 25) mg/l\nCynk (0,20 - 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002, metoda A","categories":["water","materials"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Copper","range":"(0,04 - 25) mg/l"},{"name":"Zinc","range":"(0,20 - 10) mg/l"}],"search_en":"Water intended for human consumption Flame atomic absorption spectrometry (FAAS) Copper Zinc PN-ISO 8288:2002, metoda A","technique_en":"Flame atomic absorption spectrometry (FAAS)","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"铜","range":"(0,04 - 25) mg/l"},{"name":"锌","range":"(0,20 - 10) mg/l"}],"search_zh":"生活饮用水 火焰原子吸收光谱法（FAAS） 铜 锌 PN-ISO 8288:2002, metoda A","technique_zh":"火焰原子吸收光谱法（FAAS）","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f57e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie sodu","parameters":[{"name":"Zakres","range":"(2,50 - 500) mg/l"}],"technique":"Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","techniques":["Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)"],"computed":[],"activity":"Stężenie sodu\nZakres (2,50 - 500) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","reference":"PN-ISO 9964-3:1994","norm_bases":["PN-ISO 9964-3:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie sodu\nZakres (2,50 - 500) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES) PN-ISO 9964-3:1994 Woda do spozycia przez ludzi Stezenie sodu\nZakres (2,50 - 500) mg/l\nMetoda plomieniowej emisyjnej spektrometrii atomowej (FAES) PN-ISO 9964-3:1994","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sodium concentration","parameters_en":[{"name":"Range","range":"(2,50 - 500) mg/l"}],"search_en":"Water intended for human consumption Sodium concentration Flame atomic emission spectrometry (FAES) Range PN-ISO 9964-3:1994","technique_en":"Flame atomic emission spectrometry (FAES)","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2,50 - 500) mg/l"}],"search_zh":"生活饮用水 钠浓度 火焰原子发射光谱法（FAES） 范围 PN-ISO 9964-3:1994","test_object_zh":"生活饮用水","methodology_zh":"钠浓度","technique_zh":"火焰原子发射光谱法（FAES）"},{"_id":"6a8375e3af14b9c0e7b1f57f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"Chlorki","range":"(1,0 - 1000) mg/l"},{"name":"Azotyny","range":"(0,030 - 10) mg/l"},{"name":"Azotany","range":"(1,0 - 1000) mg/l"},{"name":"Fluorki","range":"(0,10 - 10) mg/l"},{"name":"Siarczany","range":"(1,0 - 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorki (1,0 - 1000) mg/l\nAzotyny (0,030 - 10) mg/l\nAzotany (1,0 - 1000) mg/l\nFluorki (0,10 - 10) mg/l\nSiarczany (1,0 - 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie anionów\nZakres:\nChlorki (1,0 - 1000) mg/l\nAzotyny (0,030 - 10) mg/l\nAzotany (1,0 - 1000) mg/l\nFluorki (0,10 - 10) mg/l\nSiarczany (1,0 - 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Woda do spozycia przez ludzi Stezenie anionow\nZakres:\nChlorki (1,0 - 1000) mg/l\nAzotyny (0,030 - 10) mg/l\nAzotany (1,0 - 1000) mg/l\nFluorki (0,10 - 10) mg/l\nSiarczany (1,0 - 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Anion concentrations","parameters_en":[{"name":"Chlorides","range":"(1,0 - 1000) mg/l"},{"name":"Nitrites","range":"(0,030 - 10) mg/l"},{"name":"Nitrates","range":"(1,0 - 1000) mg/l"},{"name":"Fluorides","range":"(0,10 - 10) mg/l"},{"name":"Sulfates","range":"(1,0 - 1000) mg/l"}],"search_en":"Water intended for human consumption Anion concentrations Ion chromatography with conductometric detection (IC-CD) Chlorides Nitrites Nitrates Fluorides Sulfates PN-EN ISO 10304-1:2009 +AC:2012","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water intended for human consumption","methodology_zh":"阴离子浓度","parameters_zh":[{"name":"氯化物","range":"(1,0 - 1000) mg/l"},{"name":"亚硝酸盐","range":"(0,030 - 10) mg/l"},{"name":"硝酸盐","range":"(1,0 - 1000) mg/l"},{"name":"氟化物","range":"(0,10 - 10) mg/l"},{"name":"硫酸盐","range":"(1,0 - 1000) mg/l"}],"search_zh":"生活饮用水 阴离子浓度 离子色谱-电导检测法（IC-CD） 氯化物 亚硝酸盐 硝酸盐 氟化物 硫酸盐 PN-EN ISO 10304-1:2009 +AC:2012","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f580","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi, rtęci i uranu","parameters":[{"name":"Ołów","range":"(1,0 - 100) μg/l"},{"name":"Kadm","range":"(0,50 - 50) μg/l"},{"name":"Nikiel","range":"(1,0 - 100) μg/l"},{"name":"Chrom","range":"(5,0 - 100) μg/l"},{"name":"Glin","range":"(10,0 - 2000) μg/l"},{"name":"Mangan","range":"(5,0 - 100) μg/l"},{"name":"Antymon","range":"(0,50 - 50) μg/l"},{"name":"Arsen","range":"(1,0 - 100) μg/l"},{"name":"Selen","range":"(1,0 - 100) μg/l"},{"name":"Bor","range":"(50 - 5000) μg/l"},{"name":"Srebro","range":"(0,5 - 100) μg/l"},{"name":"Miedź","range":"(5,0 - 2100) μg/l"},{"name":"Rtęć","range":"(0,10 - 5,0) μg/l"},{"name":"Uran","range":"(1,0 - 100) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS)"],"computed":[],"activity":"Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi, rtęci i uranu\nZakres:\nOłów (1,0 - 100) μg/l\nKadm (0,50 - 50) μg/l\nNikiel (1,0 - 100) μg/l\nChrom (5,0 - 100) μg/l\nGlin (10,0 - 2000) μg/l\nMangan (5,0 - 100) μg/l\nAntymon (0,50 - 50) μg/l\nArsen (1,0 - 100) μg/l\nSelen (1,0 - 100) μg/l\nBor (50 - 5000) μg/l\nSrebro (0,5 - 100) μg/l\nMiedź (5,0 - 2100) μg/l\nRtęć (0,10 - 5,0) μg/l\nUran (1,0 - 100) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi, rtęci i uranu\nZakres:\nOłów (1,0 - 100) μg/l\nKadm (0,50 - 50) μg/l\nNikiel (1,0 - 100) μg/l\nChrom (5,0 - 100) μg/l\nGlin (10,0 - 2000) μg/l\nMangan (5,0 - 100) μg/l\nAntymon (0,50 - 50) μg/l\nArsen (1,0 - 100) μg/l\nSelen (1,0 - 100) μg/l\nBor (50 - 5000) μg/l\nSrebro (0,5 - 100) μg/l\nMiedź (5,0 - 2100) μg/l\nRtęć (0,10 - 5,0) μg/l\nUran (1,0 - 100) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS) PN-EN ISO 17294-2:2024-04 Woda do spozycia przez ludzi Stezenie olowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi, rteci i uranu\nZakres:\nOlow (1,0 - 100) μg/l\nKadm (0,50 - 50) μg/l\nNikiel (1,0 - 100) μg/l\nChrom (5,0 - 100) μg/l\nGlin (10,0 - 2000) μg/l\nMangan (5,0 - 100) μg/l\nAntymon (0,50 - 50) μg/l\nArsen (1,0 - 100) μg/l\nSelen (1,0 - 100) μg/l\nBor (50 - 5000) μg/l\nSrebro (0,5 - 100) μg/l\nMiedz (5,0 - 2100) μg/l\nRtec (0,10 - 5,0) μg/l\nUran (1,0 - 100) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP MS) PN-EN ISO 17294-2:2024-04","categories":["water","materials"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Lead","range":"(1,0 - 100) μg/l"},{"name":"Cadmium","range":"(0,50 - 50) μg/l"},{"name":"Nickel","range":"(1,0 - 100) μg/l"},{"name":"Chromium","range":"(5,0 - 100) μg/l"},{"name":"Aluminium","range":"(10,0 - 2000) μg/l"},{"name":"Manganese","range":"(5,0 - 100) μg/l"},{"name":"Antimony","range":"(0,50 - 50) μg/l"},{"name":"Arsenic","range":"(1,0 - 100) μg/l"},{"name":"Selenium","range":"(1,0 - 100) μg/l"},{"name":"Boron","range":"(50 - 5000) μg/l"},{"name":"Silver","range":"(0,5 - 100) μg/l"},{"name":"Copper","range":"(5,0 - 2100) μg/l"},{"name":"Mercury","range":"(0,10 - 5,0) μg/l"},{"name":"Uranium","range":"(1,0 - 100) μg/l"}],"search_en":"Water intended for human consumption Lead Cadmium Nickel Chromium Aluminium Manganese Antimony Arsenic Selenium Boron Silver Copper Mercury Uranium PN-EN ISO 17294-2:2024-04","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"铅","range":"(1,0 - 100) μg/l"},{"name":"镉","range":"(0,50 - 50) μg/l"},{"name":"镍","range":"(1,0 - 100) μg/l"},{"name":"铬","range":"(5,0 - 100) μg/l"},{"name":"铝","range":"(10,0 - 2000) μg/l"},{"name":"锰","range":"(5,0 - 100) μg/l"},{"name":"锑","range":"(0,50 - 50) μg/l"},{"name":"砷","range":"(1,0 - 100) μg/l"},{"name":"硒","range":"(1,0 - 100) μg/l"},{"name":"硼","range":"(50 - 5000) μg/l"},{"name":"银","range":"(0,5 - 100) μg/l"},{"name":"铜","range":"(5,0 - 2100) μg/l"},{"name":"汞","range":"(0,10 - 5,0) μg/l"},{"name":"铀","range":"(1,0 - 100) μg/l"}],"search_zh":"生活饮用水 铅 镉 镍 铬 铝 锰 锑 砷 硒 硼 银 铜 汞 铀 PN-EN ISO 17294-2:2024-04","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f581","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie łatwolotnych chlorowcopochodnych węglowodorów:","parameters":[{"name":"Trichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM)"},{"name":"Zakres","range":"(5,0 -120) μg/l"},{"name":"Tetrachloroeten, trichloroeten","range":"(1,0 - 20,5) μg/l"},{"name":"Tetrachlorometan","range":"(0,20 - 4,10) μg/l"},{"name":"1,2-dichloroetan","range":"(0,80 - 6,4) μg/l"},{"name":"Suma THM (z obliczeń)"},{"name":"Suma tetrachloroetenu i trichloroetenu ( z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD, HS-GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD, HS-GC-ECD)"],"computed":[],"activity":"Stężenie łatwolotnych chlorowcopochodnych węglowodorów:\nZakres:\nTrichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM)\nZakres (5,0 -120) μg/l\nTetrachloroeten, trichloroeten (1,0 - 20,5) μg/l\nTetrachlorometan (0,20 - 4,10) μg/l\n1,2-dichloroetan (0,80 - 6,4) μg/l\nSuma THM (z obliczeń)\nSuma tetrachloroetenu i trichloroetenu ( z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD, HS-GC-ECD)","reference":"PN-EN ISO 10301:2002 Rozdział 2 i 3","norm_bases":["PN-EN ISO 10301:2002 Rozdział 2 i 3"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie łatwolotnych chlorowcopochodnych węglowodorów:\nZakres:\nTrichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM)\nZakres (5,0 -120) μg/l\nTetrachloroeten, trichloroeten (1,0 - 20,5) μg/l\nTetrachlorometan (0,20 - 4,10) μg/l\n1,2-dichloroetan (0,80 - 6,4) μg/l\nSuma THM (z obliczeń)\nSuma tetrachloroetenu i trichloroetenu ( z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD, HS-GC-ECD) PN-EN ISO 10301:2002 Rozdział 2 i 3 Woda do spozycia przez ludzi Stezenie latwolotnych chlorowcopochodnych weglowodorow:\nZakres:\nTrichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM)\nZakres (5,0 -120) μg/l\nTetrachloroeten, trichloroeten (1,0 - 20,5) μg/l\nTetrachlorometan (0,20 - 4,10) μg/l\n1,2-dichloroetan (0,80 - 6,4) μg/l\nSuma THM (z obliczen)\nSuma tetrachloroetenu i trichloroetenu ( z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD, HS-GC-ECD) PN-EN ISO 10301:2002 Rozdzial 2 i 3","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Trichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM)"},{"name":"Range","range":"(5,0 -120) μg/l"},{"name":"Tetrachloroeten, trichloroeten","range":"(1,0 - 20,5) μg/l"},{"name":"Tetrachloromethane","range":"(0,20 - 4,10) μg/l"},{"name":"1,2-dichloroethane","range":"(0,80 - 6,4) μg/l"},{"name":"Sum of THM (calculated)"},{"name":"Suma tetrachloroetenu i trichloroetenu ( z obliczeń)"}],"search_en":"Water intended for human consumption Gas chromatography with electron capture detection (GC-ECD, HS-GC-ECD) Range Tetrachloromethane 1,2-dichloroethane Sum of THM (calculated) PN-EN ISO 10301:2002 Rozdział 2 i 3","technique_en":"Gas chromatography with electron capture detection (GC-ECD, HS-GC-ECD)","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"Trichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM)"},{"name":"范围","range":"(5,0 -120) μg/l"},{"name":"Tetrachloroeten, trichloroeten","range":"(1,0 - 20,5) μg/l"},{"name":"四氯化碳","range":"(0,20 - 4,10) μg/l"},{"name":"1,2-二氯乙烷","range":"(0,80 - 6,4) μg/l"},{"name":"三卤甲烷总量（由计算得出）"},{"name":"Suma tetrachloroetenu i trichloroetenu ( z obliczeń)"}],"search_zh":"生活饮用水 范围 四氯化碳 1,2-二氯乙烷 三卤甲烷总量（由计算得出） PN-EN ISO 10301:2002 Rozdział 2 i 3","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f582","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie pestycydów","parameters":[{"name":"Aldryna","range":"(0,005 - 0,060) μg/l"},{"name":"Dieldryna","range":"(0,005 - 0,060) μg/l"},{"name":"Heptachlor","range":"(0,005 - 0,060) μg/l"},{"name":"Heptachlor endo-epoxyd A"},{"name":"Zakres","range":"(0,005 - 0,060) μg/l"},{"name":"Heptachlor exo-epoxyd B","range":"(0,005 - 0,060) μg/l"},{"name":"Chlordan-cis","range":"(0,010 - 0,120) μg/l"},{"name":"Chlordan-trans","range":"(0,010 - 0,120) μg/l"},{"name":"DDD","range":"(0,010 - 0,120) μg/l"},{"name":"DDE","range":"(0,010 - 0,120) μg/l"},{"name":"DDT","range":"(0,010 - 0,120) μg/l"},{"name":"Endosulfan α","range":"(0,010 - 0,120) μg/l"},{"name":"Endosulfan β","range":"(0,010 - 0,120) μg/l"},{"name":"Trifluralin","range":"(0,010 - 0,120) μg/l"},{"name":"PeCB","range":"(0,010- 0,120) μg/l"},{"name":"HCB","range":"(0,010 - 0,120) μg/l"},{"name":"HCH α","range":"(0,010 - 0,120) μg/l"},{"name":"HCH β","range":"(0,010 - 0,120) μg/l"},{"name":"HCH γ","range":"(0,010 - 0,120) μg/l"},{"name":"HCH δ","range":"(0,010 - 0,120) μg/l"},{"name":"Permetryna","range":"(0,010 - 0,120) μg/l"},{"name":"Cypermetryna","range":"(0,010 - 0,120) μg/l"},{"name":"Fenwalerat","range":"(0,010 - 0,120) μg/l"},{"name":"Deltametryna","range":"(0,010 - 0,120) μg/l"},{"name":"Suma pestycydów (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie pestycydów\nZakres:\nAldryna (0,005 - 0,060) μg/l\nDieldryna (0,005 - 0,060) μg/l\nHeptachlor (0,005 - 0,060) μg/l\nHeptachlor endo-epoxyd A\nZakres (0,005 - 0,060) μg/l\nHeptachlor exo-epoxyd B (0,005 - 0,060) μg/l\nChlordan-cis (0,010 - 0,120) μg/l\nChlordan-trans (0,010 - 0,120) μg/l\nDDD (0,010 - 0,120) μg/l\nDDE (0,010 - 0,120) μg/l\nDDT (0,010 - 0,120) μg/l\nEndosulfan α (0,010 - 0,120) μg/l\nEndosulfan β (0,010 - 0,120) μg/l\nTrifluralin (0,010 - 0,120) μg/l\nPeCB (0,010- 0,120) μg/l\nHCB (0,010 - 0,120) μg/l\nHCH α (0,010 - 0,120) μg/l\nHCH β (0,010 - 0,120) μg/l\nHCH γ (0,010 - 0,120) μg/l\nHCH δ (0,010 - 0,120) μg/l\nPermetryna (0,010 - 0,120) μg/l\nCypermetryna (0,010 - 0,120) μg/l\nFenwalerat (0,010 - 0,120) μg/l\nDeltametryna (0,010 - 0,120) μg/l\nSuma pestycydów (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie pestycydów\nZakres:\nAldryna (0,005 - 0,060) μg/l\nDieldryna (0,005 - 0,060) μg/l\nHeptachlor (0,005 - 0,060) μg/l\nHeptachlor endo-epoxyd A\nZakres (0,005 - 0,060) μg/l\nHeptachlor exo-epoxyd B (0,005 - 0,060) μg/l\nChlordan-cis (0,010 - 0,120) μg/l\nChlordan-trans (0,010 - 0,120) μg/l\nDDD (0,010 - 0,120) μg/l\nDDE (0,010 - 0,120) μg/l\nDDT (0,010 - 0,120) μg/l\nEndosulfan α (0,010 - 0,120) μg/l\nEndosulfan β (0,010 - 0,120) μg/l\nTrifluralin (0,010 - 0,120) μg/l\nPeCB (0,010- 0,120) μg/l\nHCB (0,010 - 0,120) μg/l\nHCH α (0,010 - 0,120) μg/l\nHCH β (0,010 - 0,120) μg/l\nHCH γ (0,010 - 0,120) μg/l\nHCH δ (0,010 - 0,120) μg/l\nPermetryna (0,010 - 0,120) μg/l\nCypermetryna (0,010 - 0,120) μg/l\nFenwalerat (0,010 - 0,120) μg/l\nDeltametryna (0,010 - 0,120) μg/l\nSuma pestycydów (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda do spozycia przez ludzi Stezenie pestycydow\nZakres:\nAldryna (0,005 - 0,060) μg/l\nDieldryna (0,005 - 0,060) μg/l\nHeptachlor (0,005 - 0,060) μg/l\nHeptachlor endo-epoxyd A\nZakres (0,005 - 0,060) μg/l\nHeptachlor exo-epoxyd B (0,005 - 0,060) μg/l\nChlordan-cis (0,010 - 0,120) μg/l\nChlordan-trans (0,010 - 0,120) μg/l\nDDD (0,010 - 0,120) μg/l\nDDE (0,010 - 0,120) μg/l\nDDT (0,010 - 0,120) μg/l\nEndosulfan α (0,010 - 0,120) μg/l\nEndosulfan β (0,010 - 0,120) μg/l\nTrifluralin (0,010 - 0,120) μg/l\nPeCB (0,010- 0,120) μg/l\nHCB (0,010 - 0,120) μg/l\nHCH α (0,010 - 0,120) μg/l\nHCH β (0,010 - 0,120) μg/l\nHCH γ (0,010 - 0,120) μg/l\nHCH δ (0,010 - 0,120) μg/l\nPermetryna (0,010 - 0,120) μg/l\nCypermetryna (0,010 - 0,120) μg/l\nFenwalerat (0,010 - 0,120) μg/l\nDeltametryna (0,010 - 0,120) μg/l\nSuma pestycydow (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pesticide concentration","parameters_en":[{"name":"Aldrin","range":"(0,005 - 0,060) μg/l"},{"name":"Dieldrin","range":"(0,005 - 0,060) μg/l"},{"name":"Heptachlor","range":"(0,005 - 0,060) μg/l"},{"name":"Heptachlor endo-epoxyd A"},{"name":"Range","range":"(0,005 - 0,060) μg/l"},{"name":"Heptachlor exo-epoxyd B","range":"(0,005 - 0,060) μg/l"},{"name":"Chlordane-cis","range":"(0,010 - 0,120) μg/l"},{"name":"Chlordane-trans","range":"(0,010 - 0,120) μg/l"},{"name":"DDD","range":"(0,010 - 0,120) μg/l"},{"name":"DDE","range":"(0,010 - 0,120) μg/l"},{"name":"DDT","range":"(0,010 - 0,120) μg/l"},{"name":"Endosulfan α","range":"(0,010 - 0,120) μg/l"},{"name":"Endosulfan β","range":"(0,010 - 0,120) μg/l"},{"name":"Trifluralin","range":"(0,010 - 0,120) μg/l"},{"name":"PeCB","range":"(0,010- 0,120) μg/l"},{"name":"HCB","range":"(0,010 - 0,120) μg/l"},{"name":"HCH α","range":"(0,010 - 0,120) μg/l"},{"name":"HCH β","range":"(0,010 - 0,120) μg/l"},{"name":"HCH γ","range":"(0,010 - 0,120) μg/l"},{"name":"HCH δ","range":"(0,010 - 0,120) μg/l"},{"name":"Permethrin","range":"(0,010 - 0,120) μg/l"},{"name":"Cypermethrin","range":"(0,010 - 0,120) μg/l"},{"name":"Fenvalerate","range":"(0,010 - 0,120) μg/l"},{"name":"Deltamethrin","range":"(0,010 - 0,120) μg/l"},{"name":"Sum of pesticides (calculated)"}],"search_en":"Water intended for human consumption Pesticide concentration Gas chromatography with electron capture detection (GC-ECD) Aldrin Dieldrin Heptachlor Range Chlordane-cis Chlordane-trans HCB Permethrin Cypermethrin Fenvalerate Deltamethrin Sum of pesticides (calculated) PN-EN ISO 6468:2002","technique_en":"Gas chromatography with electron capture detection (GC-ECD)","test_object_en":"Water intended for human consumption","methodology_zh":"农药浓度","parameters_zh":[{"name":"艾氏剂","range":"(0,005 - 0,060) μg/l"},{"name":"狄氏剂","range":"(0,005 - 0,060) μg/l"},{"name":"七氯","range":"(0,005 - 0,060) μg/l"},{"name":"Heptachlor endo-epoxyd A"},{"name":"范围","range":"(0,005 - 0,060) μg/l"},{"name":"Heptachlor exo-epoxyd B","range":"(0,005 - 0,060) μg/l"},{"name":"Chlordan-cis","range":"(0,010 - 0,120) μg/l"},{"name":"Chlordan-trans","range":"(0,010 - 0,120) μg/l"},{"name":"DDD","range":"(0,010 - 0,120) μg/l"},{"name":"DDE","range":"(0,010 - 0,120) μg/l"},{"name":"DDT","range":"(0,010 - 0,120) μg/l"},{"name":"Endosulfan α","range":"(0,010 - 0,120) μg/l"},{"name":"Endosulfan β","range":"(0,010 - 0,120) μg/l"},{"name":"Trifluralin","range":"(0,010 - 0,120) μg/l"},{"name":"PeCB","range":"(0,010- 0,120) μg/l"},{"name":"六氯苯（HCB）","range":"(0,010 - 0,120) μg/l"},{"name":"HCH α","range":"(0,010 - 0,120) μg/l"},{"name":"HCH β","range":"(0,010 - 0,120) μg/l"},{"name":"HCH γ","range":"(0,010 - 0,120) μg/l"},{"name":"HCH δ","range":"(0,010 - 0,120) μg/l"},{"name":"Permetryna","range":"(0,010 - 0,120) μg/l"},{"name":"Cypermetryna","range":"(0,010 - 0,120) μg/l"},{"name":"Fenwalerat","range":"(0,010 - 0,120) μg/l"},{"name":"Deltametryna","range":"(0,010 - 0,120) μg/l"},{"name":"农药总量（由计算得出）"}],"search_zh":"生活饮用水 农药浓度 气相色谱-电子捕获检测法（GC-ECD） 艾氏剂 狄氏剂 七氯 范围 六氯苯（HCB） 农药总量（由计算得出） PN-EN ISO 6468:2002","technique_zh":"气相色谱-电子捕获检测法（GC-ECD）","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f583","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chlorynów","parameters":[{"name":"Zakres","range":"(0,050 - 10) mg/l"},{"name":"Stężenie chloranów"},{"name":"Zakres","range":"(0,050 - 10) mg/l"},{"name":"Suma chlorynów i chloranów (z obliczeń)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chlorynów\nZakres:\nZakres (0,050 - 10) mg/l\nStężenie chloranów\nZakres (0,050 - 10) mg/l\nSuma chlorynów i chloranów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chlorynów\nZakres:\nZakres (0,050 - 10) mg/l\nStężenie chloranów\nZakres (0,050 - 10) mg/l\nSuma chlorynów i chloranów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda do spozycia przez ludzi Stezenie chlorynow\nZakres:\nZakres (0,050 - 10) mg/l\nStezenie chloranow\nZakres (0,050 - 10) mg/l\nSuma chlorynow i chloranow (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chlorite concentration","parameters_en":[{"name":"Range","range":"(0,050 - 10) mg/l"},{"name":"Chlorate concentration"},{"name":"Range","range":"(0,050 - 10) mg/l"},{"name":"Sum of chlorites and chlorates (calculated)"}],"search_en":"Water intended for human consumption Chlorite concentration Ion chromatography with conductometric detection (IC-CD) Range Chlorate concentration Range Sum of chlorites and chlorates (calculated) PN-EN ISO 10304-4:2022-08","technique_en":"Ion chromatography with conductometric detection (IC-CD)","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,050 - 10) mg/l"},{"name":"氯酸盐浓度"},{"name":"范围","range":"(0,050 - 10) mg/l"},{"name":"亚氯酸盐与氯酸盐总量（由计算得出）"}],"search_zh":"生活饮用水 亚氯酸盐浓度 离子色谱-电导检测法（IC-CD） 范围 氯酸盐浓度 范围 亚氯酸盐与氯酸盐总量（由计算得出） PN-EN ISO 10304-4:2022-08","technique_zh":"离子色谱-电导检测法（IC-CD）","test_object_zh":"生活饮用水","methodology_zh":"亚氯酸盐浓度"},{"_id":"6a8375e3af14b9c0e7b1f584","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie bromianów","parameters":[{"name":"Zakres","range":"(2,0 - 50) μg/l"}],"technique":"Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/VIS)","techniques":["Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/VIS)"],"computed":[],"activity":"Stężenie bromianów\nZakres (2,0 - 50) μg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/VIS)","reference":"PN-EN ISO 11206:2013-07","norm_bases":["PN-EN ISO 11206:2013-07"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie bromianów\nZakres (2,0 - 50) μg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/VIS) PN-EN ISO 11206:2013-07 Woda do spozycia przez ludzi Stezenie bromianow\nZakres (2,0 - 50) μg/l\nMetoda chromatografii jonowej z detekcja spektrofotometryczna (IC-UV/VIS) PN-EN ISO 11206:2013-07","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bromate concentration","parameters_en":[{"name":"Range","range":"(2,0 - 50) μg/l"}],"search_en":"Water intended for human consumption Bromate concentration Ion chromatography with spectrophotometric detection (IC-UV/VIS) Range PN-EN ISO 11206:2013-07","technique_en":"Ion chromatography with spectrophotometric detection (IC-UV/VIS)","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2,0 - 50) μg/l"}],"search_zh":"生活饮用水 溴酸盐浓度 离子色谱-分光光度检测法（IC-UV/VIS） 范围 PN-EN ISO 11206:2013-07","test_object_zh":"生活饮用水","methodology_zh":"溴酸盐浓度","technique_zh":"离子色谱-分光光度检测法（IC-UV/VIS）"},{"_id":"6a8375e3af14b9c0e7b1f585","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Benzo(b)fluoranten"},{"name":"Zakres","range":"(0,0020 - 0,030) μg/l"},{"name":"Benzo(k)fluoranten","range":"(0,0020 - 0,030) μg/l"},{"name":"Benzo(ghi)perylen","range":"(0,0020 - 0,030) μg/l"},{"name":"Indeno","range":"(1,2,3-cd)piren"},{"name":"(0,0020 - 0,030) μg/l"},{"name":"Suma WWA (z obliczeń)"},{"name":"Benzo(a)piren"},{"name":"Zakres","range":"(0,0020 - 0,030) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD); Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nBenzo(b)fluoranten\nZakres (0,0020 - 0,030) μg/l\nBenzo(k)fluoranten (0,0020 - 0,030) μg/l\nBenzo(ghi)perylen (0,0020 - 0,030) μg/l\nIndeno (1,2,3-cd)piren\n(0,0020 - 0,030) μg/l\nSuma WWA (z obliczeń)\nBenzo(a)piren\nZakres (0,0020 - 0,030) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD); Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-LI-16 wydanie nr 5 z dnia 02.12.2025 r.","norm_bases":["PB-LI-16 wydanie nr 5 z dnia 02.12.2025 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nBenzo(b)fluoranten\nZakres (0,0020 - 0,030) μg/l\nBenzo(k)fluoranten (0,0020 - 0,030) μg/l\nBenzo(ghi)perylen (0,0020 - 0,030) μg/l\nIndeno (1,2,3-cd)piren\n(0,0020 - 0,030) μg/l\nSuma WWA (z obliczeń)\nBenzo(a)piren\nZakres (0,0020 - 0,030) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD); Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-LI-16 wydanie nr 5 z dnia 02.12.2025 r. Woda do spozycia przez ludzi Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nBenzo(b)fluoranten\nZakres (0,0020 - 0,030) μg/l\nBenzo(k)fluoranten (0,0020 - 0,030) μg/l\nBenzo(ghi)perylen (0,0020 - 0,030) μg/l\nIndeno (1,2,3-cd)piren\n(0,0020 - 0,030) μg/l\nSuma WWA (z obliczen)\nBenzo(a)piren\nZakres (0,0020 - 0,030) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD); Metoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-LI-16 wydanie nr 5 z dnia 02.12.2025 r.","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Concentration of polycyclic aromatic hydrocarbons (PAH)","parameters_en":[{"name":"Benzo(b)fluoranthene"},{"name":"Range","range":"(0,0020 - 0,030) μg/l"},{"name":"Benzo(k)fluoranthene","range":"(0,0020 - 0,030) μg/l"},{"name":"Benzo(ghi)perylene","range":"(0,0020 - 0,030) μg/l"},{"name":"Indeno","range":"(1,2,3-cd)piren"},{"name":"(0,0020 - 0,030) μg/l"},{"name":"Sum of PAH (calculated)"},{"name":"Benzo(a)pyrene"},{"name":"Range","range":"(0,0020 - 0,030) μg/l"}],"search_en":"Water intended for human consumption Concentration of polycyclic aromatic hydrocarbons (PAH) High-performance liquid chromatography with fluorescence detection (HPLC-FLD); High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Benzo(b)fluoranthene Range Benzo(k)fluoranthene Benzo(ghi)perylene Indeno (0,0020 - 0,030) μg/l Sum of PAH (calculated) Benzo(a)pyrene Range PB-LI-16 wydanie nr 5 z dnia 02.12.2025 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD); High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"苯并(b)荧蒽"},{"name":"范围","range":"(0,0020 - 0,030) μg/l"},{"name":"苯并(k)荧蒽","range":"(0,0020 - 0,030) μg/l"},{"name":"苯并(ghi)苝","range":"(0,0020 - 0,030) μg/l"},{"name":"茚并","range":"(1,2,3-cd)piren"},{"name":"(0,0020 - 0,030) μg/l"},{"name":"多环芳烃总量（计算值）"},{"name":"苯并(a)芘"},{"name":"范围","range":"(0,0020 - 0,030) μg/l"}],"search_zh":"生活饮用水 多环芳烃（PAHs）浓度 苯并(b)荧蒽 范围 苯并(k)荧蒽 苯并(ghi)苝 茚并 多环芳烃总量（计算值） 苯并(a)芘 范围 PB-LI-16 wydanie nr 5 z dnia 02.12.2025 r.","test_object_zh":"生活饮用水","methodology_zh":"多环芳烃（PAHs）浓度"},{"_id":"6a8375e3af14b9c0e7b1f586","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie bisfenolu A","parameters":[{"name":"Zakres","range":"(0,50 – 7,5) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie bisfenolu A\nZakres (0,50 – 7,5) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-LI-37 wydanie nr 2 z dnia 19.12.2025 r.","norm_bases":["PB-LI-37 wydanie nr 2 z dnia 19.12.2025 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY; ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie bisfenolu A\nZakres (0,50 – 7,5) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-LI-37 wydanie nr 2 z dnia 19.12.2025 r. Woda do spozycia przez ludzi Stezenie bisfenolu A\nZakres (0,50 – 7,5) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-LI-37 wydanie nr 2 z dnia 19.12.2025 r.","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Bisphenol A concentration","parameters_en":[{"name":"Range","range":"(0,50 – 7,5) μg/l"}],"search_en":"Water intended for human consumption Bisphenol A concentration High-performance liquid chromatography with fluorescence detection (HPLC-FLD) Range PB-LI-37 wydanie nr 2 z dnia 19.12.2025 r.","technique_en":"High-performance liquid chromatography with fluorescence detection (HPLC-FLD)","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,50 – 7,5) μg/l"}],"search_zh":"生活饮用水 双酚 A 浓度 高效液相色谱-荧光检测法（HPLC-FLD） 范围 PB-LI-37 wydanie nr 2 z dnia 19.12.2025 r.","technique_zh":"高效液相色谱-荧光检测法（HPLC-FLD）","test_object_zh":"生活饮用水","methodology_zh":"双酚 A 浓度"},{"_id":"6a8375e3af14b9c0e7b1f587","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(20,0 - 1000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (20,0 - 1000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie żelaza\nZakres (20,0 - 1000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda (w tym woda na plywalni) Stezenie zelaza\nZakres (20,0 - 1000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(20,0 - 1000) μg/l"}],"search_en":"Water (including swimming pool water) Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20,0 - 1000) μg/l"}],"search_zh":"水（含游泳池水） 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f588","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalni) pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 - 10,0)"}],"search_en":"Water (including swimming pool water) pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 - 10,0)"}],"search_zh":"水（含游泳池水） pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f589","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(84 - 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (84 - 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Przewodność elektryczna właściwa\nZakres (84 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda (w tym woda na plywalni) Przewodnosc elektryczna wlasciwa\nZakres (84 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(84 - 5000) μS/cm"}],"search_en":"Water (including swimming pool water) Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(84 - 5000) μS/cm"}],"search_zh":"水（含游泳池水） 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f58a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,060 - 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,060 - 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie azotu amonowego\nZakres (0,060 - 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda (w tym woda na plywalni) Stezenie azotu amonowego\nZakres (0,060 - 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,060 - 1,0) mg/l"}],"search_en":"Water (including swimming pool water) Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,060 - 1,0) mg/l"}],"search_zh":"水（含游泳池水） 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f58b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 - 10) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 - 10) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Mętność\nZakres (0,20 - 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym woda na plywalni) Metnosc\nZakres (0,20 - 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 - 10) NTU"}],"search_en":"Water (including swimming pool water) Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 - 10) NTU"}],"search_zh":"水（含游泳池水） 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f58c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(1,0 - 25) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (1,0 - 25) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie ogólnego węgla organicznego\nZakres (1,0 - 25) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda (w tym woda na plywalni) Stezenie ogolnego wegla organicznego\nZakres (1,0 - 25) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration","parameters_en":[{"name":"Range","range":"(1,0 - 25) mg/l"}],"search_en":"Water (including swimming pool water) Total organic carbon concentration High-temperature combustion with IR detection Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"范围","range":"(1,0 - 25) mg/l"}],"search_zh":"水（含游泳池水） 总有机碳浓度 高温燃烧红外检测法 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"水（含游泳池水）","methodology_zh":"总有机碳浓度"},{"_id":"6a8375e3af14b9c0e7b1f58d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Indeks nadmanganianowy (utlenialność)","parameters":[{"name":"Zakres","range":"(0,55 - 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy (utlenialność)\nZakres (0,55 - 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Indeks nadmanganianowy (utlenialność)\nZakres (0,55 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalni) Indeks nadmanganianowy (utlenialnosc)\nZakres (0,55 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index (oxidisability)","parameters_en":[{"name":"Range","range":"(0,55 - 10,0) mg/l"}],"search_en":"Water (including swimming pool water) Permanganate index (oxidisability) Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"范围","range":"(0,55 - 10,0) mg/l"}],"search_zh":"水（含游泳池水） 高锰酸盐指数（耗氧量） 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）","methodology_zh":"高锰酸盐指数（耗氧量）"},{"_id":"6a8375e3af14b9c0e7b1f58e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 - 5000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 - 5000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie chlorków\nZakres (5,0 - 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda (w tym woda na plywalni) Stezenie chlorkow\nZakres (5,0 - 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 - 5000) mg/l"}],"search_en":"Water (including swimming pool water) Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 - 5000) mg/l"}],"search_zh":"水（含游泳池水） 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f58f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(20,0 - 1000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (20,0 - 1000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (20,0 - 1000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (20,0 - 1000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Iron concentration","parameters_en":[{"name":"Range","range":"(20,0 - 1000) μg/l"}],"search_en":"Water intended for human consumption Iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铁浓度","parameters_zh":[{"name":"范围","range":"(20,0 - 1000) μg/l"}],"search_zh":"生活饮用水 铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f590","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 - 10,0)"}],"search_en":"Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 - 10,0)"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f591","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(84- 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (84- 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (84- 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (84- 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(84- 5000) μS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(84- 5000) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f592","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,060 - 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,060 - 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotu amonowego\nZakres (0,060 - 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie azotu amonowego\nZakres (0,060 - 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium nitrogen concentration","parameters_en":[{"name":"Range","range":"(0,060 - 1,0) mg/l"}],"search_en":"Water intended for human consumption Ammonium nitrogen concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"氨氮浓度","parameters_zh":[{"name":"范围","range":"(0,060 - 1,0) mg/l"}],"search_zh":"生活饮用水 氨氮浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f593","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 - 10) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 - 10) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,20 - 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,20 - 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,20 - 10) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,20 - 10) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f594","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(1,0 - 25) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (1,0 - 25) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie ogólnego węgla organicznego\nZakres (1,0 - 25) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda do spozycia przez ludzi Stezenie ogolnego wegla organicznego\nZakres (1,0 - 25) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total organic carbon concentration","parameters_en":[{"name":"Range","range":"(1,0 - 25) mg/l"}],"search_en":"Water intended for human consumption Total organic carbon concentration High-temperature combustion with IR detection Range PN-EN 1484:1999","technique_en":"High-temperature combustion with IR detection","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(1,0 - 25) mg/l"}],"search_zh":"生活饮用水 总有机碳浓度 高温燃烧红外检测法 范围 PN-EN 1484:1999","technique_zh":"高温燃烧红外检测法","test_object_zh":"生活饮用水","methodology_zh":"总有机碳浓度"},{"_id":"6a8375e3af14b9c0e7b1f595","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy (utlenialność)","parameters":[{"name":"Zakres","range":"(0,55 - 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy (utlenialność)\nZakres (0,55 - 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Indeks nadmanganianowy (utlenialność)\nZakres (0,55 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Indeks nadmanganianowy (utlenialnosc)\nZakres (0,55 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index (oxidisability)","parameters_en":[{"name":"Range","range":"(0,55 - 10,0) mg/l"}],"search_en":"Water intended for human consumption Permanganate index (oxidisability) Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,55 - 10,0) mg/l"}],"search_zh":"生活饮用水 高锰酸盐指数（耗氧量） 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水","methodology_zh":"高锰酸盐指数（耗氧量）"},{"_id":"6a8375e3af14b9c0e7b1f596","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 - 1000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 - 1000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 - 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 - 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(5 - 1000) mg/l CaCO3"}],"search_en":"Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(5 - 1000) mg/l CaCO3"}],"search_zh":"生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f597","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2 - 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2 - 100) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie wapnia\nZakres (2 - 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda do spozycia przez ludzi Stezenie wapnia\nZakres (2 - 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Calcium concentration","parameters_en":[{"name":"Range","range":"(2 - 100) mg/l"}],"search_en":"Water intended for human consumption Calcium concentration Titrimetric method Range PN-ISO 6058:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2 - 100) mg/l"}],"search_zh":"生活饮用水 钙浓度 滴定法 范围 PN-ISO 6058:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水","methodology_zh":"钙浓度"},{"_id":"6a8375e3af14b9c0e7b1f598","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 Załącznik A","norm_bases":["PN-C-04554-4:1999 Załącznik A"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Załącznik A Woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999 Zalacznik A","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnesium concentration (calculated)","search_en":"Water intended for human consumption Magnesium concentration (calculated) PN-C-04554-4:1999 Załącznik A","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 镁浓度（计算值） PN-C-04554-4:1999 Załącznik A","test_object_zh":"生活饮用水","methodology_zh":"镁浓度（计算值）"},{"_id":"6a8375e3af14b9c0e7b1f599","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 - 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 - 300) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 - 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 - 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,0 - 300) mg/l"}],"search_en":"Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,0 - 300) mg/l"}],"search_zh":"生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f59a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym woda na plywalni) Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water (including swimming pool water) Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","methodology_zh":"大肠菌群计数","search_zh":"水（含游泳池水） 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f59b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym woda na plywalni) Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water (including swimming pool water) Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"水（含游泳池水） 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f59c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda (w tym woda na plywalni) Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Escherichia coli","search_en":"Water (including swimming pool water) Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water (including swimming pool water)","search_zh":"水（含游泳池水） 大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水（含游泳池水）","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a8375e3af14b9c0e7b1f59d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda (w tym woda na plywalni) Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria","search_en":"Water (including swimming pool water) Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water (including swimming pool water)","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"水（含游泳池水） 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f59e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym woda na plywalni) Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water (including swimming pool water) Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","methodology_zh":"铜绿假单胞菌计数","search_zh":"水（含游泳池水） 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f59f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Ogólna liczba mikroorganizmów w temperaturze 36oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalni) Ogolna liczba mikroorganizmow w temperaturze 36oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total count of microorganisms at 36oC","search_en":"Water (including swimming pool water) Total count of microorganisms at 36oC Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water (including swimming pool water)","search_zh":"水（含游泳池水） 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5a0","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Liczba gronkowców koagulazododatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"Metodyka PZH ZHK z dnia 23.04.2007 r.","norm_bases":["Metodyka PZH ZHK z dnia 23.04.2007 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej Metodyka PZH ZHK z dnia 23.04.2007 r. Woda (w tym woda na plywalni) Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej Metodyka PZH ZHK z dnia 23.04.2007 r.","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coagulase-positive staphylococci count","search_en":"Water (including swimming pool water) Coagulase-positive staphylococci count Membrane filtration method Metodyka PZH ZHK z dnia 23.04.2007 r.","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","search_zh":"水（含游泳池水） 凝固酶阳性葡萄球菌计数 膜过滤法 Metodyka PZH ZHK z dnia 23.04.2007 r.","technique_zh":"膜过滤法","methodology_zh":"凝固酶阳性葡萄球菌计数","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5a1","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda (w tym woda na plywalni) Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water (including swimming pool water) Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water (including swimming pool water)","methodology_zh":"粪肠球菌计数","search_zh":"水（含游泳池水） 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5a2","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Coliform bacteria count","search_en":"Water intended for human consumption Coliform bacteria count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群计数","search_zh":"生活饮用水 大肠菌群计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5a3","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Escherichia coli count","search_en":"Water intended for human consumption Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠埃希氏菌（Escherichia coli）计数","search_zh":"生活饮用水 大肠埃希氏菌（Escherichia coli）计数 膜过滤法 PN-EN ISO 9308-1:2014-12 +A1:2017-04","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5a4","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of coliform bacteria","search_en":"Water intended for human consumption Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water intended for human consumption","methodology_zh":"大肠菌群最可能数（MPN）","search_zh":"生活饮用水 大肠菌群最可能数（MPN） 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5a5","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Most probable number of Escherichia coli","search_en":"Water intended for human consumption Most probable number of Escherichia coli MPN method PN-EN ISO 9308-2:2014-06","technique_en":"MPN method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 大肠埃希氏菌最可能数 最可能数法（MPN） PN-EN ISO 9308-2:2014-06","technique_zh":"最可能数法（MPN）","test_object_zh":"生活饮用水","methodology_zh":"大肠埃希氏菌最可能数"},{"_id":"6a8375e3af14b9c0e7b1f5a6","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 22oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 22oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total count of microorganisms at a temperature of 22oC","search_en":"Water intended for human consumption Total count of microorganisms at a temperature of 22oC Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5a7","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 36oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 36oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total count of microorganisms at 36oC","search_en":"Water intended for human consumption Total count of microorganisms at 36oC Plate method (pour plate) PN-EN ISO 6222:2004","technique_en":"Plate method (pour plate)","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 平板法（倾注培养） PN-EN ISO 6222:2004","technique_zh":"平板法（倾注培养）","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5a8","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Pseudomonas aeruginosa count","search_en":"Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"铜绿假单胞菌计数","search_zh":"生活饮用水 铜绿假单胞菌计数 膜过滤法 PN-EN ISO 16266:2009","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5a9","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Intestinal enterococci count","search_en":"Water intended for human consumption Intestinal enterococci count Membrane filtration method PN-EN ISO 7899-2:2004","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","methodology_zh":"粪肠球菌计数","search_zh":"生活饮用水 粪肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5aa","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda do spozycia przez ludzi Liczba bakterii Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water","microbiology"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of Clostridium perfringens bacteria (including spores)","search_en":"Water intended for human consumption Count of Clostridium perfringens bacteria (including spores) Membrane filtration method PN-EN ISO 14189:2016-10","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 膜过滤法 PN-EN ISO 14189:2016-10","technique_zh":"膜过滤法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5ab","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii z rodzaju Legionella","parameters":[{"name":"Matryca A"},{"name":"Procedura 5 (pożywka BCYE)"},{"name":"Procedura 7 (pożywka GVPC)"},{"name":"Posiew bezpośredni"},{"name":"Matryca A"},{"name":"Procedura 1 (pożywka BCYE i BCYE+AB)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella\nZakres:\nMatryca A\nProcedura 5 (pożywka BCYE)\nProcedura 7 (pożywka GVPC)\nPosiew bezpośredni\nMatryca A\nProcedura 1 (pożywka BCYE i BCYE+AB)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019:12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019:12"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nZakres:\nMatryca A\nProcedura 5 (pożywka BCYE)\nProcedura 7 (pożywka GVPC)\nPosiew bezpośredni\nMatryca A\nProcedura 1 (pożywka BCYE i BCYE+AB)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019:12 Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nZakres:\nMatryca A\nProcedura 5 (pozywka BCYE)\nProcedura 7 (pozywka GVPC)\nPosiew bezposredni\nMatryca A\nProcedura 1 (pozywka BCYE i BCYE+AB)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019:12","categories":["microbiology","water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of bacteria of the genus Legionella","parameters_en":[{"name":"Matrix A"},{"name":"Procedura 5 (pożywka BCYE)"},{"name":"Procedura 7 (pożywka GVPC)"},{"name":"Posiew bezpośredni"},{"name":"Matrix A"},{"name":"Procedura 1 (pożywka BCYE i BCYE+AB)"}],"search_en":"Water intended for human consumption Count of bacteria of the genus Legionella Membrane filtration method Matrix A Matrix A PN-EN ISO 11731:2017-08 +Ap1:2019:12","technique_en":"Membrane filtration method","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019:12","technique_zh":"膜过滤法","test_object_zh":"生活饮用水","methodology_zh":"军团菌属细菌计数"},{"_id":"6a8375e3af14b9c0e7b1f5ac","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba bakterii z rodzaju Legionella","parameters":[{"name":"Matryca B"},{"name":"Procedura 7 (pożywka GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella\nZakres:\nMatryca B\nProcedura 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019:12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019:12"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella\nZakres:\nMatryca B\nProcedura 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019:12 Woda na plywalniach Liczba bakterii z rodzaju Legionella\nZakres:\nMatryca B\nProcedura 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019:12","categories":["microbiology","water"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Count of bacteria of the genus Legionella","search_en":"Swimming pool water Count of bacteria of the genus Legionella Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019:12","technique_en":"Membrane filtration method","test_object_en":"Swimming pool water","search_zh":"游泳池水 军团菌属细菌计数 膜过滤法 PN-EN ISO 11731:2017-08 +Ap1:2019:12","technique_zh":"膜过滤法","test_object_zh":"游泳池水","methodology_zh":"军团菌属细菌计数"},{"_id":"6a8375e3af14b9c0e7b1f5ad","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Identyfikacja grup serologicznych bakterii z rodzaju Legionella","parameters":[],"technique":"Metoda serologiczna, test aglutynacji lateksowej","techniques":["Metoda serologiczna, test aglutynacji lateksowej"],"computed":[],"activity":"Identyfikacja grup serologicznych bakterii z rodzaju Legionella\nMetoda serologiczna, test aglutynacji lateksowej","reference":"Instrukcja producenta Oxoid Legionella Latex Test Wydanie X5057F, luty 2025","norm_bases":["Instrukcja producenta Oxoid Legionella Latex Test Wydanie X5057F, luty 2025"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Identyfikacja grup serologicznych bakterii z rodzaju Legionella\nMetoda serologiczna, test aglutynacji lateksowej Instrukcja producenta Oxoid Legionella Latex Test Wydanie X5057F, luty 2025 Woda do spozycia przez ludzi, Woda na plywalniach Identyfikacja grup serologicznych bakterii z rodzaju Legionella\nMetoda serologiczna, test aglutynacji lateksowej Instrukcja producenta Oxoid Legionella Latex Test Wydanie X5057F, luty 2025","categories":["microbiology","water"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption, Swimming pool water Instrukcja producenta Oxoid Legionella Latex Test Wydanie X5057F, luty 2025","test_object_en":"Water intended for human consumption, Swimming pool water","search_zh":"生活饮用水、游泳池水 Instrukcja producenta Oxoid Legionella Latex Test Wydanie X5057F, luty 2025","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a8375e3af14b9c0e7b1f5ae","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Identyfikacja grup serologicznych bakterii z rodzaju Legionella","parameters":[],"technique":"Metoda serologiczna, test aglutynacji lateksowej","techniques":["Metoda serologiczna, test aglutynacji lateksowej"],"computed":[],"activity":"Identyfikacja grup serologicznych bakterii z rodzaju Legionella\nMetoda serologiczna, test aglutynacji lateksowej","reference":"Instrukcja producenta BIOMAXIMA Legionella Latex Rapid Test Aktualizacja 13.10.2025","norm_bases":["Instrukcja producenta BIOMAXIMA Legionella Latex Rapid Test Aktualizacja 13.10.2025"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Identyfikacja grup serologicznych bakterii z rodzaju Legionella\nMetoda serologiczna, test aglutynacji lateksowej Instrukcja producenta BIOMAXIMA Legionella Latex Rapid Test Aktualizacja 13.10.2025 Woda do spozycia przez ludzi, Woda na plywalniach Identyfikacja grup serologicznych bakterii z rodzaju Legionella\nMetoda serologiczna, test aglutynacji lateksowej Instrukcja producenta BIOMAXIMA Legionella Latex Rapid Test Aktualizacja 13.10.2025","categories":["microbiology","water"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Water intended for human consumption, Swimming pool water Instrukcja producenta BIOMAXIMA Legionella Latex Rapid Test Aktualizacja 13.10.2025","test_object_en":"Water intended for human consumption, Swimming pool water","search_zh":"生活饮用水、游泳池水 Instrukcja producenta BIOMAXIMA Legionella Latex Rapid Test Aktualizacja 13.10.2025","test_object_zh":"生活饮用水、游泳池水"},{"_id":"6a8375e3af14b9c0e7b1f5af","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba colifagów somatycznych","parameters":[],"technique":"Metoda płytek dwuwarstwowych (DAL)","techniques":["Metoda płytek dwuwarstwowych (DAL)"],"computed":[],"activity":"Liczba colifagów somatycznych\nMetoda płytek dwuwarstwowych (DAL)","reference":"PN-EN ISO 10705-2:2005","norm_bases":["PN-EN ISO 10705-2:2005"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba colifagów somatycznych\nMetoda płytek dwuwarstwowych (DAL) PN-EN ISO 10705-2:2005 Woda do spozycia przez ludzi Liczba colifagow somatycznych\nMetoda plytek dwuwarstwowych (DAL) PN-EN ISO 10705-2:2005","categories":["water"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Somatic coliphage count","search_en":"Water intended for human consumption Somatic coliphage count PN-EN ISO 10705-2:2005","test_object_en":"Water intended for human consumption","search_zh":"生活饮用水 体细胞噬菌体数 PN-EN ISO 10705-2:2005","test_object_zh":"生活饮用水","methodology_zh":"体细胞噬菌体数"},{"_id":"6a8375e3af14b9c0e7b1f5b0","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Indukcja magnetyczna w zakresie częstotliwości (20 - 50) Hz","parameters":[{"name":"zakres","range":"0,5 μT - 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości (20 - 50) Hz\nzakres 0,5 μT - 19 mT\nMetoda pomiarowa bezpośrednia (uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180"],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Indukcja magnetyczna w zakresie częstotliwości (20 - 50) Hz\nzakres 0,5 μT - 19 mT\nMetoda pomiarowa bezpośrednia (uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Indukcja magnetyczna w zakresie czestotliwosci (20 - 50) Hz\nzakres 0,5 μT - 19 mT\nMetoda pomiarowa bezposrednia (uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 - 180","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density in the frequency range (20 - 50) Hz","parameters_en":[{"name":"range","range":"0,5 μT - 19 mT"}],"search_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices Magnetic flux density in the frequency range (20 - 50) Hz Direct measurement method (simplified) range Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","technique_en":"Direct measurement method (simplified)","test_object_en":"Workplace environment - electromagnetic field in the workspace from magnetotherapy devices","parameters_zh":[{"name":"范围","range":"0,5 μT - 19 mT"}],"search_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场 直接测量法（简化） 范围 Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","test_object_zh":"工作场所环境 — 工作空间内来自磁疗设备的电磁场","technique_zh":"直接测量法（简化）"},{"_id":"6a8375e3af14b9c0e7b1f5b1","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Środowisko pracy - pola elektromagnetyczne","methodology":"Natężenie pola elektrycznego w paśmie częstotliwości:","parameters":[{"name":"10 Hz - 400 kHz"},{"name":"zakres","range":"1 V/m - 50 kV/m"},{"name":"400 kHz - 3 MHz"},{"name":"zakres","range":"(0,5 - 300) V/m"},{"name":"3 MHz - 6 GHz"},{"name":"zakres","range":"(0,8 - 800) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w paśmie częstotliwości:\nZakres:\n10 Hz - 400 kHz\nzakres 1 V/m - 50 kV/m\n400 kHz - 3 MHz\nzakres (0,5 - 300) V/m\n3 MHz - 6 GHz\nzakres (0,8 - 800) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pola elektromagnetyczne Natężenie pola elektrycznego w paśmie częstotliwości:\nZakres:\n10 Hz - 400 kHz\nzakres 1 V/m - 50 kV/m\n400 kHz - 3 MHz\nzakres (0,5 - 300) V/m\n3 MHz - 6 GHz\nzakres (0,8 - 800) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy - pola elektromagnetyczne Natezenie pola elektrycznego w pasmie czestotliwosci:\nZakres:\n10 Hz - 400 kHz\nzakres 1 V/m - 50 kV/m\n400 kHz - 3 MHz\nzakres (0,5 - 300) V/m\n3 MHz - 6 GHz\nzakres (0,8 - 800) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electric field strength in the frequency band:","parameters_en":[{"name":"10 Hz - 400 kHz"},{"name":"range","range":"1 V/m - 50 kV/m"},{"name":"400 kHz - 3 MHz"},{"name":"range","range":"(0,5 - 300) V/m"},{"name":"3 MHz - 6 GHz"},{"name":"range","range":"(0,8 - 800) V/m"}],"search_en":"Workplace environment - electromagnetic fields Electric field strength in the frequency band: Direct measurement method 10 Hz - 400 kHz range 400 kHz - 3 MHz range 3 MHz - 6 GHz range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic fields","search_zh":"下列频段内的电场强度： 直接测量法 10 Hz - 400 kHz 范围 400 kHz - 3 MHz 范围 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法","parameters_zh":[{"name":"10 Hz - 400 kHz"},{"name":"范围","range":"1 V/m - 50 kV/m"},{"name":"400 kHz - 3 MHz"},{"name":"范围","range":"(0,5 - 300) V/m"},{"name":"3 MHz - 6 GHz"},{"name":"范围","range":"(0,8 - 800) V/m"}],"methodology_zh":"下列频段内的电场强度："},{"_id":"6a8375e3af14b9c0e7b1f5b2","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Środowisko pracy - pola elektromagnetyczne","methodology":"Indukcja magnetyczna w zakresie częstotliwości:","parameters":[{"name":"0Hz zakres","range":"(0,1 - 1000) mT"},{"name":"10 Hz - 400 kHz"},{"name":"zakres","range":"0,1 μT - 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości:\nZakres:\n0Hz zakres (0,1 - 1000) mT\n10 Hz - 400 kHz\nzakres 0,1 μT - 19 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pola elektromagnetyczne Indukcja magnetyczna w zakresie częstotliwości:\nZakres:\n0Hz zakres (0,1 - 1000) mT\n10 Hz - 400 kHz\nzakres 0,1 μT - 19 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy - pola elektromagnetyczne Indukcja magnetyczna w zakresie czestotliwosci:\nZakres:\n0Hz zakres (0,1 - 1000) mT\n10 Hz - 400 kHz\nzakres 0,1 μT - 19 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic flux density in the frequency range:","parameters_en":[{"name":"0Hz range","range":"(0,1 - 1000) mT"},{"name":"10 Hz - 400 kHz"},{"name":"range","range":"0,1 μT - 19 mT"}],"search_en":"Workplace environment - electromagnetic fields Magnetic flux density in the frequency range: Direct measurement method 0Hz range 10 Hz - 400 kHz range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic fields","search_zh":"下列频率范围内的磁感应强度： 直接测量法 10 Hz - 400 kHz 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法","parameters_zh":[{"name":"0Hz zakres","range":"(0,1 - 1000) mT"},{"name":"10 Hz - 400 kHz"},{"name":"范围","range":"0,1 μT - 19 mT"}],"methodology_zh":"下列频率范围内的磁感应强度："},{"_id":"6a8375e3af14b9c0e7b1f5b3","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Środowisko pracy - pola elektromagnetyczne","methodology":"Natężenie pola magnetycznego w paśmie częstotliwości:","parameters":[{"name":"27 MHz - 1,0 GHz"},{"name":"zakres","range":"(0,015 - 8,0) A/m"},{"name":"800 MHz - 6 GHz (z obliczeń)"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola magnetycznego w paśmie częstotliwości:\nZakres:\n27 MHz - 1,0 GHz\nzakres (0,015 - 8,0) A/m\n800 MHz - 6 GHz (z obliczeń)\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego\nPotwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pola elektromagnetyczne Natężenie pola magnetycznego w paśmie częstotliwości:\nZakres:\n27 MHz - 1,0 GHz\nzakres (0,015 - 8,0) A/m\n800 MHz - 6 GHz (z obliczeń)\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy - pola elektromagnetyczne Natezenie pola magnetycznego w pasmie czestotliwosci:\nZakres:\n27 MHz - 1,0 GHz\nzakres (0,015 - 8,0) A/m\n800 MHz - 6 GHz (z obliczen)\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Magnetic field strength in the frequency band:","parameters_en":[{"name":"27 MHz - 1,0 GHz"},{"name":"range","range":"(0,015 - 8,0) A/m"},{"name":"800 MHz - 6 GHz (z obliczeń)"}],"search_en":"Workplace environment - electromagnetic fields Magnetic field strength in the frequency band: Direct measurement method 27 MHz - 1,0 GHz range PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_en":"Direct measurement method","test_object_en":"Workplace environment - electromagnetic fields","search_zh":"下列频段内的磁场强度： 直接测量法 范围 PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","technique_zh":"直接测量法","parameters_zh":[{"name":"27 MHz - 1,0 GHz"},{"name":"范围","range":"(0,015 - 8,0) A/m"},{"name":"800 MHz - 6 GHz (z obliczeń)"}],"methodology_zh":"下列频段内的磁场强度："},{"_id":"6a8375e3af14b9c0e7b1f5b4","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność, Produkty rolne, Pasze, Woda, Woda do spożycia przez ludzi","methodology":"Stężenie aktywności radionuklidu 137Cs","parameters":[{"name":"Zakres","range":"(2,0 - 10000) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"computed":[],"activity":"Stężenie aktywności radionuklidu 137Cs\nZakres (2,0 - 10000) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"PB-LFR-01 wydanie nr 5 z dnia 09.12.2021 r.","norm_bases":["PB-LFR-01 wydanie nr 5 z dnia 09.12.2021 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność, Produkty rolne, Pasze, Woda, Woda do spożycia przez ludzi Stężenie aktywności radionuklidu 137Cs\nZakres (2,0 - 10000) Bq/kg\nMetoda spektrometrii promieniowania gamma PB-LFR-01 wydanie nr 5 z dnia 09.12.2021 r. Zywnosc, Produkty rolne, Pasze, Woda, Woda do spozycia przez ludzi Stezenie aktywnosci radionuklidu 137Cs\nZakres (2,0 - 10000) Bq/kg\nMetoda spektrometrii promieniowania gamma PB-LFR-01 wydanie nr 5 z dnia 09.12.2021 r.","categories":["food","water"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"137Cs radionuclide activity concentration","parameters_en":[{"name":"Range","range":"(2,0 - 10000) Bq/kg"}],"search_en":"Food, Agricultural products, Feed, Water, Water intended for human consumption 137Cs radionuclide activity concentration Gamma-ray spectrometry method Range PB-LFR-01 wydanie nr 5 z dnia 09.12.2021 r.","technique_en":"Gamma-ray spectrometry method","test_object_en":"Food, Agricultural products, Feed, Water, Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(2,0 - 10000) Bq/kg"}],"search_zh":"放射性核素 137Cs 的活度浓度 γ 能谱法 范围 PB-LFR-01 wydanie nr 5 z dnia 09.12.2021 r.","technique_zh":"γ 能谱法","methodology_zh":"放射性核素 137Cs 的活度浓度"},{"_id":"6a8375e3af14b9c0e7b1f5b5","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie aktywności radionuklidu 222Rn","parameters":[{"name":"Zakres","range":"(5 - 200) Bq/l"}],"technique":"Metoda spektrometrii ciekłoscyntylacyjnej","techniques":["Metoda spektrometrii ciekłoscyntylacyjnej"],"computed":[],"activity":"Stężenie aktywności radionuklidu 222Rn\nZakres (5 - 200) Bq/l\nMetoda spektrometrii ciekłoscyntylacyjnej","reference":"PN-EN ISO 13164-4:2023-12","norm_bases":["PN-EN ISO 13164-4:2023-12"],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie aktywności radionuklidu 222Rn\nZakres (5 - 200) Bq/l\nMetoda spektrometrii ciekłoscyntylacyjnej PN-EN ISO 13164-4:2023-12 Woda do spozycia przez ludzi Stezenie aktywnosci radionuklidu 222Rn\nZakres (5 - 200) Bq/l\nMetoda spektrometrii ciekloscyntylacyjnej PN-EN ISO 13164-4:2023-12","categories":["water"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Activity concentration of radionuclide 222Rn","parameters_en":[{"name":"Range","range":"(5 - 200) Bq/l"}],"search_en":"Water intended for human consumption Activity concentration of radionuclide 222Rn Liquid scintillation spectrometry method Range PN-EN ISO 13164-4:2023-12","technique_en":"Liquid scintillation spectrometry method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(5 - 200) Bq/l"}],"search_zh":"生活饮用水 范围 PN-EN ISO 13164-4:2023-12","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5b6","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie aktywności radionuklidu 3H","parameters":[{"name":"Zakres","range":"(10 -200) Bq/l"}],"technique":"Metoda spektrometrii ciekłoscyntylacyjnej","techniques":["Metoda spektrometrii ciekłoscyntylacyjnej"],"computed":[],"activity":"Stężenie aktywności radionuklidu 3H\nZakres (10 -200) Bq/l\nMetoda spektrometrii ciekłoscyntylacyjnej","reference":"PN-EN ISO 9698:2019-06","norm_bases":["PN-EN ISO 9698:2019-06"],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie aktywności radionuklidu 3H\nZakres (10 -200) Bq/l\nMetoda spektrometrii ciekłoscyntylacyjnej PN-EN ISO 9698:2019-06 Woda do spozycia przez ludzi Stezenie aktywnosci radionuklidu 3H\nZakres (10 -200) Bq/l\nMetoda spektrometrii ciekloscyntylacyjnej PN-EN ISO 9698:2019-06","categories":["water"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Activity concentration of radionuclide 3H","parameters_en":[{"name":"Range","range":"(10 -200) Bq/l"}],"search_en":"Water intended for human consumption Activity concentration of radionuclide 3H Liquid scintillation spectrometry method Range PN-EN ISO 9698:2019-06","technique_en":"Liquid scintillation spectrometry method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(10 -200) Bq/l"}],"search_zh":"生活饮用水 范围 PN-EN ISO 9698:2019-06","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5b7","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Urządzenia stosowane w radiografii ogólnej cyfrowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-12 wydanie nr 5 z dnia 11.01.2023 r.","norm_bases":["Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)","PB-LFR-12 wydanie nr 5 z dnia 11.01.2023 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane w radiografii ogólnej cyfrowej Testy specjalistyczne Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-12 wydanie nr 5 z dnia 11.01.2023 r. Urzadzenia stosowane w radiografii ogolnej cyfrowej Testy specjalistyczne Zalacznik nr 1 i 2 do Rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-12 wydanie nr 5 z dnia 11.01.2023 r.","categories":["other"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Equipment used in general digital radiography Specialist tests Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-12 wydanie nr 5 z dnia 11.01.2023 r.","test_object_en":"Equipment used in general digital radiography","methodology_zh":"专项检测","search_zh":"数字普通放射摄影用设备 专项检测 Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-12 wydanie nr 5 z dnia 11.01.2023 r.","test_object_zh":"数字普通放射摄影用设备"},{"_id":"6a8375e3af14b9c0e7b1f5b8","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Urządzenia stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii cyfrowej, Urządzenia stosowane w stomatologii – aparaty do zdjęć wewnątrzustnych","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-04 wydanie nr 8 z dnia 10.02.2025 r.","norm_bases":["Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)","PB-LFR-04 wydanie nr 8 z dnia 10.02.2025 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii cyfrowej, Urządzenia stosowane w stomatologii – aparaty do zdjęć wewnątrzustnych Testy specjalistyczne Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-04 wydanie nr 8 z dnia 10.02.2025 r. Urzadzenia stosowane w stomatologii – aparaty do zdjec pantomograficznych oraz cefalometrii cyfrowej, Urzadzenia stosowane w stomatologii – aparaty do zdjec wewnatrzustnych Testy specjalistyczne Zalacznik nr 1 do Rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-04 wydanie nr 8 z dnia 10.02.2025 r.","categories":["other"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Specialist tests Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-04 wydanie nr 8 z dnia 10.02.2025 r.","methodology_zh":"专项检测","search_zh":"专项检测 Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-04 wydanie nr 8 z dnia 10.02.2025 r."},{"_id":"6a8375e3af14b9c0e7b1f5b9","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Urządzenia stosowane w stomatologicznej tomografii komputerowej wiązki stożkowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-14 wydanie nr 5 z dnia 11.01.2023 r.","norm_bases":["Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)","PB-LFR-14 wydanie nr 5 z dnia 11.01.2023 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane w stomatologicznej tomografii komputerowej wiązki stożkowej Testy specjalistyczne Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-14 wydanie nr 5 z dnia 11.01.2023 r. Urzadzenia stosowane w stomatologicznej tomografii komputerowej wiazki stozkowej Testy specjalistyczne Zalacznik nr 1 do Rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-14 wydanie nr 5 z dnia 11.01.2023 r.","categories":["other"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Equipment used in dental cone beam computed tomography Specialist tests Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-14 wydanie nr 5 z dnia 11.01.2023 r.","test_object_en":"Equipment used in dental cone beam computed tomography","methodology_zh":"专项检测","search_zh":"口腔锥形束计算机断层扫描设备 专项检测 Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-14 wydanie nr 5 z dnia 11.01.2023 r.","test_object_zh":"口腔锥形束计算机断层扫描设备"},{"_id":"6a8375e3af14b9c0e7b1f5ba","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Urządzenia stosowane we fluoroskopii i angiografii","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-08 wydanie nr 8 z dnia 11.01.2023 r.","norm_bases":["Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)","PB-LFR-08 wydanie nr 8 z dnia 11.01.2023 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane we fluoroskopii i angiografii Testy specjalistyczne Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-08 wydanie nr 8 z dnia 11.01.2023 r. Urzadzenia stosowane we fluoroskopii i angiografii Testy specjalistyczne Zalacznik nr 1 do Rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-08 wydanie nr 8 z dnia 11.01.2023 r.","categories":["other"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Equipment used in fluoroscopy and angiography Specialist tests Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-08 wydanie nr 8 z dnia 11.01.2023 r.","test_object_en":"Equipment used in fluoroscopy and angiography","methodology_zh":"专项检测","search_zh":"透视与血管造影用设备 专项检测 Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-08 wydanie nr 8 z dnia 11.01.2023 r.","test_object_zh":"透视与血管造影用设备"},{"_id":"6a8375e3af14b9c0e7b1f5bb","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Urządzenia stosowane w mammografii cyfrowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-13 wydanie nr 6 z dnia 11.01.2023 r.","norm_bases":["Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)","PB-LFR-13 wydanie nr 6 z dnia 11.01.2023 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane w mammografii cyfrowej Testy specjalistyczne Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-13 wydanie nr 6 z dnia 11.01.2023 r. Urzadzenia stosowane w mammografii cyfrowej Testy specjalistyczne Zalacznik nr 1 i 2 do Rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-13 wydanie nr 6 z dnia 11.01.2023 r.","categories":["other"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Equipment used in digital mammography Specialist tests Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-13 wydanie nr 6 z dnia 11.01.2023 r.","test_object_en":"Equipment used in digital mammography","methodology_zh":"专项检测","search_zh":"数字乳腺摄影用设备 专项检测 Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-13 wydanie nr 6 z dnia 11.01.2023 r.","test_object_zh":"数字乳腺摄影用设备"},{"_id":"6a8375e3af14b9c0e7b1f5bc","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Monitory stosowane do prezentacji obrazów medycznych","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-15 wydanie nr 5 z dnia 11.01.2023 r.","norm_bases":["Załącznik nr 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)","PB-LFR-15 wydanie nr 5 z dnia 11.01.2023 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Monitory stosowane do prezentacji obrazów medycznych Testy specjalistyczne Załącznik nr 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-15 wydanie nr 5 z dnia 11.01.2023 r. Monitory stosowane do prezentacji obrazow medycznych Testy specjalistyczne Zalacznik nr 2 do Rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-15 wydanie nr 5 z dnia 11.01.2023 r.","categories":["other"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Specialist tests","search_en":"Monitors used for the display of medical images Specialist tests Załącznik nr 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-15 wydanie nr 5 z dnia 11.01.2023 r.","test_object_en":"Monitors used for the display of medical images","methodology_zh":"专项检测","search_zh":"医学影像显示用监视器 专项检测 Załącznik nr 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-15 wydanie nr 5 z dnia 11.01.2023 r.","test_object_zh":"医学影像显示用监视器"},{"_id":"6a8375e3af14b9c0e7b1f5bd","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kał, szczepy bakteryjne","methodology":"Obecność i identyfikacja pałeczek z rodzaju Salmonella i Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność i identyfikacja pałeczek z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-LMK-01 wydanie nr 3 z dnia 10.11.2021 r. w oparciu o publikacje metodyczne","norm_bases":["PB-LMK-01 wydanie nr 3 z dnia 10.11.2021 r. w oparciu o publikacje metodyczne"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, szczepy bakteryjne Obecność i identyfikacja pałeczek z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-LMK-01 wydanie nr 3 z dnia 10.11.2021 r. w oparciu o publikacje metodyczne Kal, szczepy bakteryjne Obecnosc i identyfikacja paleczek z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-LMK-01 wydanie nr 3 z dnia 10.11.2021 r. w oparciu o publikacje metodyczne","categories":["microbiology"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence and identification of rods of the genera Salmonella and Shigella","search_en":"Faeces, bacterial strains Presence and identification of rods of the genera Salmonella and Shigella Culture method with biochemical and serological confirmation PB-LMK-01 wydanie nr 3 z dnia 10.11.2021 r. w oparciu o publikacje metodyczne","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces, bacterial strains","search_zh":"沙门氏菌属与志贺氏菌属的检出与鉴定 培养法结合生化与血清学确认 PB-LMK-01 wydanie nr 3 z dnia 10.11.2021 r. w oparciu o publikacje metodyczne","technique_zh":"培养法结合生化与血清学确认","methodology_zh":"沙门氏菌属与志贺氏菌属的检出与鉴定"},{"_id":"6a8375e3af14b9c0e7b1f5be","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Szczepy bakteryjne","methodology":"Identyfikacja pałeczek z rodzaju Salmonella","parameters":[],"technique":"Metoda biochemiczna i serologiczna","techniques":["Metoda biochemiczna i serologiczna"],"computed":[],"activity":"Identyfikacja pałeczek z rodzaju Salmonella\nMetoda biochemiczna i serologiczna","reference":"Schemat White’a-Kauffmanna-Le Minora, 2007 ISO/TR 6579-3:2014","norm_bases":["Schemat White’a-Kauffmanna-Le Minora, 2007 ISO/TR 6579-3:2014"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Szczepy bakteryjne Identyfikacja pałeczek z rodzaju Salmonella\nMetoda biochemiczna i serologiczna Schemat White’a-Kauffmanna-Le Minora, 2007 ISO/TR 6579-3:2014 Szczepy bakteryjne Identyfikacja paleczek z rodzaju Salmonella\nMetoda biochemiczna i serologiczna Schemat White’a-Kauffmanna-Le Minora, 2007 ISO/TR 6579-3:2014","categories":["microbiology"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Bacterial strains Biochemical and serological method Schemat White’a-Kauffmanna-Le Minora, 2007 ISO/TR 6579-3:2014","technique_en":"Biochemical and serological method","test_object_en":"Bacterial strains","search_zh":"菌株 Schemat White’a-Kauffmanna-Le Minora, 2007 ISO/TR 6579-3:2014","test_object_zh":"菌株"},{"_id":"6a8375e3af14b9c0e7b1f5bf","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kał","methodology":"Obecność chorobotwórczych i warunkowo chorobotwórczych Gram-ujemnych pałeczek jelitowych","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność chorobotwórczych i warunkowo chorobotwórczych Gram-ujemnych pałeczek jelitowych\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-LMK-02 wydanie nr 3 z dnia 22.12.2021 r. w oparciu o publikacje metodyczne","norm_bases":["PB-LMK-02 wydanie nr 3 z dnia 22.12.2021 r. w oparciu o publikacje metodyczne"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał Obecność chorobotwórczych i warunkowo chorobotwórczych Gram-ujemnych pałeczek jelitowych\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-LMK-02 wydanie nr 3 z dnia 22.12.2021 r. w oparciu o publikacje metodyczne Kal Obecnosc chorobotworczych i warunkowo chorobotworczych Gram-ujemnych paleczek jelitowych\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-LMK-02 wydanie nr 3 z dnia 22.12.2021 r. w oparciu o publikacje metodyczne","categories":["other"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Faeces Culture method with biochemical and serological confirmation PB-LMK-02 wydanie nr 3 z dnia 22.12.2021 r. w oparciu o publikacje metodyczne","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Faeces","search_zh":"粪便 培养法结合生化与血清学确认 PB-LMK-02 wydanie nr 3 z dnia 22.12.2021 r. w oparciu o publikacje metodyczne","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"粪便"},{"_id":"6a8375e3af14b9c0e7b1f5c0","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kał","methodology":"Obecność jaj i cyst pasożytów jelitowych człowieka","parameters":[],"technique":"Metody koproskopowe","techniques":["Metody koproskopowe"],"computed":[],"activity":"Obecność jaj i cyst pasożytów jelitowych człowieka\nMetody koproskopowe","reference":"PB-LMK-05 wydanie nr 3 z dnia 07.12.2016 r. w oparciu o publikacje metodyczne","norm_bases":["PB-LMK-05 wydanie nr 3 z dnia 07.12.2016 r. w oparciu o publikacje metodyczne"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał Obecność jaj i cyst pasożytów jelitowych człowieka\nMetody koproskopowe PB-LMK-05 wydanie nr 3 z dnia 07.12.2016 r. w oparciu o publikacje metodyczne Kal Obecnosc jaj i cyst pasozytow jelitowych czlowieka\nMetody koproskopowe PB-LMK-05 wydanie nr 3 z dnia 07.12.2016 r. w oparciu o publikacje metodyczne","categories":["other"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of eggs and cysts of human intestinal parasites","search_en":"Faeces Presence of eggs and cysts of human intestinal parasites Coproscopic methods PB-LMK-05 wydanie nr 3 z dnia 07.12.2016 r. w oparciu o publikacje metodyczne","technique_en":"Coproscopic methods","test_object_en":"Faeces","search_zh":"粪便 PB-LMK-05 wydanie nr 3 z dnia 07.12.2016 r. w oparciu o publikacje metodyczne","test_object_zh":"粪便"},{"_id":"6a8375e3af14b9c0e7b1f5c1","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Biologiczne wskaźniki kontroli skuteczności procesu sterylizacji","methodology":"Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermophilus (Sporal A), Bacillus subtilis (Sporal S)","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermophilus (Sporal A), Bacillus subtilis (Sporal S)\nMetoda hodowlana","reference":"PB-LMK-03 wydanie nr 3 z dnia 04.01.2021 r. w oparciu o instrukcje producentów stosowanych wskaźników procesu sterylizacji","norm_bases":["PB-LMK-03 wydanie nr 3 z dnia 04.01.2021 r. w oparciu o instrukcje producentów stosowanych wskaźników procesu sterylizacji"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biologiczne wskaźniki kontroli skuteczności procesu sterylizacji Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermophilus (Sporal A), Bacillus subtilis (Sporal S)\nMetoda hodowlana PB-LMK-03 wydanie nr 3 z dnia 04.01.2021 r. w oparciu o instrukcje producentów stosowanych wskaźników procesu sterylizacji Biologiczne wskazniki kontroli skutecznosci procesu sterylizacji Obecnosc drobnoustrojow wskaznikowych Geobacillus stearothermophilus (Sporal A), Bacillus subtilis (Sporal S)\nMetoda hodowlana PB-LMK-03 wydanie nr 3 z dnia 04.01.2021 r. w oparciu o instrukcje producentow stosowanych wskaznikow procesu sterylizacji","categories":["microbiology"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of indicator microorganisms Geobacillus stearothermophilus (Sporal A), Bacillus subtilis (Sporal S)","search_en":"Biological indicators for the control of the effectiveness of the sterilization process Presence of indicator microorganisms Geobacillus stearothermophilus (Sporal A), Bacillus subtilis (Sporal S) Culture method PB-LMK-03 wydanie nr 3 z dnia 04.01.2021 r. w oparciu o instrukcje producentów stosowanych wskaźników procesu sterylizacji","technique_en":"Culture method","test_object_en":"Biological indicators for the control of the effectiveness of the sterilization process","search_zh":"灭菌过程效果监测用生物指示物 培养法 PB-LMK-03 wydanie nr 3 z dnia 04.01.2021 r. w oparciu o instrukcje producentów stosowanych wskaźników procesu sterylizacji","technique_zh":"培养法","test_object_zh":"灭菌过程效果监测用生物指示物"},{"_id":"6a8375e3af14b9c0e7b1f5c2","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kał E","methodology":"Obecność antygenów biologicznych czynników chorobotwórczych","parameters":[],"technique":"Metoda immunochromatograficzna (ICR)","techniques":["Metoda immunochromatograficzna (ICR)"],"computed":[],"activity":"Obecność antygenów biologicznych czynników chorobotwórczych\nMetoda immunochromatograficzna (ICR)","reference":"Instrukcje producenta","norm_bases":["Instrukcje producenta"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Kał E Obecność antygenów biologicznych czynników chorobotwórczych\nMetoda immunochromatograficzna (ICR) Instrukcje producenta Kal E Obecnosc antygenow biologicznych czynnikow chorobotworczych\nMetoda immunochromatograficzna (ICR) Instrukcje producenta","categories":["other"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Faeces E Immunochromatographic method (ICR) Instrukcje producenta","technique_en":"Immunochromatographic method (ICR)","test_object_en":"Faeces E","search_zh":"粪便 E Instrukcje producenta","test_object_zh":"粪便 E"},{"_id":"6a8375e3af14b9c0e7b1f5c3","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kał E","methodology":"Obecność antygenów biologicznych czynników chorobotwórczych","parameters":[],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"computed":[],"activity":"Obecność antygenów biologicznych czynników chorobotwórczych\nMetoda immunoenzymatyczna (ELISA)","reference":"Instrukcje producenta","norm_bases":["Instrukcje producenta"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Kał E Obecność antygenów biologicznych czynników chorobotwórczych\nMetoda immunoenzymatyczna (ELISA) Instrukcje producenta Kal E Obecnosc antygenow biologicznych czynnikow chorobotworczych\nMetoda immunoenzymatyczna (ELISA) Instrukcje producenta","categories":["other"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code","search_en":"Faeces E Enzyme immunoassay method (ELISA) Instrukcje producenta","technique_en":"Enzyme immunoassay method (ELISA)","test_object_en":"Faeces E","search_zh":"粪便 E 酶联免疫吸附法（ELISA） Instrukcje producenta","technique_zh":"酶联免疫吸附法（ELISA）","test_object_zh":"粪便 E"},{"_id":"6a8375e3af14b9c0e7b1f5c4","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 - 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym woda na plywalni) Metnosc\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 - 100) NTU"}],"search_en":"Water (including swimming pool water) Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 - 100) NTU"}],"search_zh":"水（含游泳池水） 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5c5","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,020 - 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,020 - 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332: 2001+Ap1:2016-06","norm_bases":["PN-ISO 6332: 2001+Ap1:2016-06"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie żelaza ogólnego\nZakres (0,020 - 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332: 2001+Ap1:2016-06 Woda (w tym woda na plywalni) Stezenie zelaza ogolnego\nZakres (0,020 - 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332: 2001+Ap1:2016-06","categories":["water"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,020 - 10,0) mg/l"}],"search_en":"Water (including swimming pool water) Total iron concentration Spectrophotometric method Range PN-ISO 6332: 2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 - 10,0) mg/l"}],"search_zh":"水（含游泳池水） 总铁浓度 分光光度法 范围 PN-ISO 6332: 2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5c6","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,060 - 1,30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,060 - 1,30) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie jonu amonowego\nZakres (0,060 - 1,30) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda (w tym woda na plywalni) Stezenie jonu amonowego\nZakres (0,060 - 1,30) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,060 - 1,30) mg/l"}],"search_en":"Water (including swimming pool water) Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,060 - 1,30) mg/l"}],"search_zh":"水（含游泳池水） 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5c7","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,020 - 1,312) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,020 - 1,312) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie azotynów\nZakres (0,020 - 1,312) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda (w tym woda na plywalni) Stezenie azotynow\nZakres (0,020 - 1,312) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,020 - 1,312) mg/l"}],"search_en":"Water (including swimming pool water) Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,020 - 1,312) mg/l"}],"search_zh":"水（含游泳池水） 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5c8","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,20 - 110,75) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,20 - 110,75) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-08:1982","norm_bases":["PN-C-04576-08:1982"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie azotanów\nZakres (0,20 - 110,75) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982 Woda (w tym woda na plywalni) Stezenie azotanow\nZakres (0,20 - 110,75) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982","categories":["water"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,20 - 110,75) mg/l"}],"search_en":"Water (including swimming pool water) Nitrate concentration Spectrophotometric method Range PN-C-04576-08:1982","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,20 - 110,75) mg/l"}],"search_zh":"水（含游泳池水） 硝酸盐浓度 分光光度法 范围 PN-C-04576-08:1982","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5c9","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) pH\nZakres (4,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalni) pH\nZakres (4,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 - 12,0)"}],"search_en":"Water (including swimming pool water) pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 - 12,0)"}],"search_zh":"水（含游泳池水） pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5ca","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(5 - 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 - 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Przewodność elektryczna właściwa\nZakres (5 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda (w tym woda na plywalni) Przewodnosc elektryczna wlasciwa\nZakres (5 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(5 - 5000) μS/cm"}],"search_en":"Water (including swimming pool water) Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 - 5000) μS/cm"}],"search_zh":"水（含游泳池水） 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5cb","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(8,0 - 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (8,0 - 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie chlorków\nZakres (8,0 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda (w tym woda na plywalni) Stezenie chlorkow\nZakres (8,0 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(8,0 - 400) mg/l"}],"search_en":"Water (including swimming pool water) Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(8,0 - 400) mg/l"}],"search_zh":"水（含游泳池水） 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5cc","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie glinu/aluminium","parameters":[{"name":"Zakres","range":"(0,020 - 0,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu/aluminium\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04605-02:1992","norm_bases":["PN-C-04605-02:1992"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie glinu/aluminium\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna PN-C-04605-02:1992 Woda (w tym woda na plywalni) Stezenie glinu/aluminium\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna PN-C-04605-02:1992","categories":["water","materials"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(0,020 - 0,60) mg/l"}],"search_en":"Water (including swimming pool water) Aluminium concentration Spectrophotometric method Range PN-C-04605-02:1992","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"范围","range":"(0,020 - 0,60) mg/l"}],"search_zh":"水（含游泳池水） 分光光度法 范围 PN-C-04605-02:1992","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5cd","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 - 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 - 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Indeks nadmanganianowy\nZakres (0,50 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalni) Indeks nadmanganianowy\nZakres (0,50 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 - 10,0) mg/l"}],"search_en":"Water (including swimming pool water) Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 - 10,0) mg/l"}],"search_zh":"水（含游泳池水） 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5ce","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,03 - 2,45) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,03 - 2,45) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie ortofosforanów\nZakres (0,03 - 2,45) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 Woda (w tym woda na plywalni) Stezenie ortofosforanow\nZakres (0,03 - 2,45) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,03 - 2,45) mg/l"}],"search_en":"Water (including swimming pool water) Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","parameters_zh":[{"name":"范围","range":"(0,03 - 2,45) mg/l"}],"search_zh":"水（含游泳池水） 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","methodology_zh":"正磷酸盐浓度","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5cf","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2,0 - 60) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2,0 - 60) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Barwa\nZakres (2,0 - 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C Woda (w tym woda na plywalni) Barwa\nZakres (2,0 - 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","categories":["water"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2,0 - 60) mg/l Pt"}],"search_en":"Water (including swimming pool water) Colour Spectrophotometric method Range PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2,0 - 60) mg/l Pt"}],"search_zh":"水（含游泳池水） 色度 分光光度法 范围 PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5d0","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 - 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 - 100) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 - 100) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5d1","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(11 - 700) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (11 - 700) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (11 - 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (11 - 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total content of calcium and magnesium (total hardness)","parameters_en":[{"name":"Range","range":"(11 - 700) mg/l CaCO3"}],"search_en":"Water intended for human consumption Total content of calcium and magnesium (total hardness) Titrimetric method Range PN-ISO 6059:1999","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"钙与镁总量（总硬度）","parameters_zh":[{"name":"范围","range":"(11 - 700) mg/l CaCO3"}],"search_zh":"生活饮用水 钙与镁总量（总硬度） 滴定法 范围 PN-ISO 6059:1999","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5d2","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,020 - 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,020 - 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332: 2001+Ap1:2016-06","norm_bases":["PN-ISO 6332: 2001+Ap1:2016-06"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,020 - 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332: 2001+Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,020 - 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332: 2001+Ap1:2016-06","categories":["water"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(0,020 - 10,0) mg/l"}],"search_en":"Water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332: 2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(0,020 - 10,0) mg/l"}],"search_zh":"生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332: 2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5d3","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,060 - 1,30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,060 - 1,30) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,060 - 1,30) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,060 - 1,30) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,060 - 1,30) mg/l"}],"search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,060 - 1,30) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5d4","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,020 - 1,312) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,020 - 1,312) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,020 - 1,312) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,020 - 1,312) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrite concentration","parameters_en":[{"name":"Range","range":"(0,020 - 1,312) mg/l"}],"search_en":"Water intended for human consumption Nitrite concentration Spectrophotometric method Range PN-EN 26777:1999","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"亚硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,020 - 1,312) mg/l"}],"search_zh":"生活饮用水 亚硝酸盐浓度 分光光度法 范围 PN-EN 26777:1999","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5d5","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,20 - 110,75) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,20 - 110,75) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-08:1982","norm_bases":["PN-C-04576-08:1982"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,20 - 110,75) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,20 - 110,75) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982","categories":["water"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(0,20 - 110,75) mg/l"}],"search_en":"Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-C-04576-08:1982","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(0,20 - 110,75) mg/l"}],"search_zh":"生活饮用水 硝酸盐浓度 分光光度法 范围 PN-C-04576-08:1982","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5d6","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres (4,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres (4,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 - 12,0)"}],"search_en":"Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 - 12,0)"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5d7","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(5 - 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 - 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (5 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (5 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(5 - 5000) μS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(5 - 5000) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5d8","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(8,0 - 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (8,0 - 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (8,0 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (8,0 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(8,0 - 400) mg/l"}],"search_en":"Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(8,0 - 400) mg/l"}],"search_zh":"生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5d9","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie glinu/aluminium","parameters":[{"name":"Zakres","range":"(0,020 - 0,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu/aluminium\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04605-02:1992","norm_bases":["PN-C-04605-02:1992"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie glinu/aluminium\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna PN-C-04605-02:1992 Woda do spozycia przez ludzi Stezenie glinu/aluminium\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna PN-C-04605-02:1992","categories":["water","materials"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(0,020 - 0,60) mg/l"}],"search_en":"Water intended for human consumption Aluminium concentration Spectrophotometric method Range PN-C-04605-02:1992","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,020 - 0,60) mg/l"}],"search_zh":"生活饮用水 分光光度法 范围 PN-C-04605-02:1992","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5da","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 - 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 - 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Permanganate index","parameters_en":[{"name":"Range","range":"(0,50 - 10,0) mg/l"}],"search_en":"Water intended for human consumption Permanganate index Titrimetric method Range PN-EN ISO 8467:2001","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"高锰酸盐指数","parameters_zh":[{"name":"范围","range":"(0,50 - 10,0) mg/l"}],"search_zh":"生活饮用水 高锰酸盐指数 滴定法 范围 PN-EN ISO 8467:2001","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5db","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,03 - 2,45) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,03 - 2,45) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie ortofosforanów\nZakres (0,03 - 2,45) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 Woda do spozycia przez ludzi Stezenie ortofosforanow\nZakres (0,03 - 2,45) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,03 - 2,45) mg/l"}],"search_en":"Water intended for human consumption Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,03 - 2,45) mg/l"}],"search_zh":"生活饮用水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a8375e3af14b9c0e7b1f5dc","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2,0 - 60) mg/lPt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2,0 - 60) mg/lPt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (2,0 - 60) mg/lPt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (2,0 - 60) mg/lPt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","categories":["water"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(2,0 - 60) mg/lPt"}],"search_en":"Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(2,0 - 60) mg/lPt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5dd","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kał","methodology":"Obecność pałeczek z rodzaju Salmonella i Shigella","parameters":[],"technique":"Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","techniques":["Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi"],"computed":[],"activity":"Obecność pałeczek z rodzaju Salmonella i Shigella\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","reference":"PB-LZT-10 wydanie nr 4 z dnia 11.02.2025 r. w oparciu o publikacje metodyczne","norm_bases":["PB-LZT-10 wydanie nr 4 z dnia 11.02.2025 r. w oparciu o publikacje metodyczne"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał Obecność pałeczek z rodzaju Salmonella i Shigella\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi PB-LZT-10 wydanie nr 4 z dnia 11.02.2025 r. w oparciu o publikacje metodyczne Kal Obecnosc paleczek z rodzaju Salmonella i Shigella\nMetoda hodowlana uzupelniona testami biochemicznymi i serologicznymi PB-LZT-10 wydanie nr 4 z dnia 11.02.2025 r. w oparciu o publikacje metodyczne","categories":["microbiology"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of rods of the genus Salmonella and Shigella","search_en":"Faeces Presence of rods of the genus Salmonella and Shigella Culture method supplemented with biochemical and serological tests PB-LZT-10 wydanie nr 4 z dnia 11.02.2025 r. w oparciu o publikacje metodyczne","technique_en":"Culture method supplemented with biochemical and serological tests","test_object_en":"Faeces","search_zh":"粪便 培养法，辅以生化与血清学试验 PB-LZT-10 wydanie nr 4 z dnia 11.02.2025 r. w oparciu o publikacje metodyczne","test_object_zh":"粪便","technique_zh":"培养法，辅以生化与血清学试验"},{"_id":"6a8375e3af14b9c0e7b1f5de","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda filtracji membranowej Normy Woda E Liczba drobnoustrojow\nMetoda filtracji membranowej Normy","categories":["water","microbiology"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Water E Microorganism count Membrane filtration method Normy","technique_en":"Membrane filtration method","test_object_en":"Water E","methodology_zh":"菌落总数","search_zh":"水 E 菌落总数 膜过滤法 Normy","technique_zh":"膜过滤法","test_object_zh":"水 E"},{"_id":"6a8375e3af14b9c0e7b1f5df","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Woda E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["water","microbiology"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Water E Microorganism count Plate method (pour plate) Normy","technique_en":"Plate method (pour plate)","test_object_en":"Water E","methodology_zh":"菌落总数","search_zh":"水 E 菌落总数 平板法（倾注培养） Normy","technique_zh":"平板法（倾注培养）","test_object_zh":"水 E"},{"_id":"6a8375e3af14b9c0e7b1f5e0","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda NPL","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda NPL Normy Woda E Liczba drobnoustrojow\nMetoda NPL Normy","categories":["water","microbiology"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Water E Microorganism count MPN method Normy","technique_en":"MPN method","test_object_en":"Water E","methodology_zh":"菌落总数","search_zh":"水 E 菌落总数 最可能数法（MPN） Normy","technique_zh":"最可能数法（MPN）","test_object_zh":"水 E"},{"_id":"6a8375e3af14b9c0e7b1f5e1","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["food","microbiology"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Food E Presence of microorganisms Culture method with biochemical and serological confirmation Normy","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Food E","search_zh":"食品 E 微生物的检出 培养法结合生化与血清学确认 Normy","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"食品 E","methodology_zh":"微生物的检出"},{"_id":"6a8375e3af14b9c0e7b1f5e2","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy","categories":["food","microbiology"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Food E Presence of microorganisms Culture method with biochemical confirmation Normy","technique_en":"Culture method with biochemical confirmation","test_object_en":"Food E","search_zh":"食品 E 微生物的检出 培养法结合生化确认 Normy","technique_zh":"培养法结合生化确认","test_object_zh":"食品 E","methodology_zh":"微生物的检出"},{"_id":"6a8375e3af14b9c0e7b1f5e3","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Zywnosc E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["food","microbiology"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Food E Microorganism count Plate method (pour plate) Normy","technique_en":"Plate method (pour plate)","test_object_en":"Food E","methodology_zh":"菌落总数","search_zh":"食品 E 菌落总数 平板法（倾注培养） Normy","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E"},{"_id":"6a8375e3af14b9c0e7b1f5e4","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Zywnosc E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy","categories":["food","microbiology"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Food E Microorganism count Plate method (spread plate) Normy","technique_en":"Plate method (spread plate)","test_object_en":"Food E","methodology_zh":"菌落总数","search_zh":"食品 E 菌落总数 平板法（表面涂布） Normy","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E"},{"_id":"6a8375e3af14b9c0e7b1f5e5","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,19 - 29,8) %"},{"name":"Zawartość białka (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu\nZakres:\nZakres (0,19 - 29,8) %\nZawartość białka (z obliczeń)\nMetoda miareczkowa","reference":"PB-LZT-19 wydanie nr 2 z dnia 20.01.2021 r.","norm_bases":["PB-LZT-19 wydanie nr 2 z dnia 20.01.2021 r."],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość azotu\nZakres:\nZakres (0,19 - 29,8) %\nZawartość białka (z obliczeń)\nMetoda miareczkowa PB-LZT-19 wydanie nr 2 z dnia 20.01.2021 r. Mieso i przetwory miesne Zawartosc azotu\nZakres:\nZakres (0,19 - 29,8) %\nZawartosc bialka (z obliczen)\nMetoda miareczkowa PB-LZT-19 wydanie nr 2 z dnia 20.01.2021 r.","categories":["food"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrogen content","parameters_en":[{"name":"Range","range":"(0,19 - 29,8) %"},{"name":"Protein content (calculated)"}],"search_en":"Meat and meat products Nitrogen content Titrimetric method Range Protein content (calculated) PB-LZT-19 wydanie nr 2 z dnia 20.01.2021 r.","technique_en":"Titrimetric method","test_object_en":"Meat and meat products","methodology_zh":"氮含量","parameters_zh":[{"name":"范围","range":"(0,19 - 29,8) %"},{"name":"蛋白质含量（计算值）"}],"search_zh":"肉与肉制品 氮含量 滴定法 范围 蛋白质含量（计算值） PB-LZT-19 wydanie nr 2 z dnia 20.01.2021 r.","technique_zh":"滴定法","test_object_zh":"肉与肉制品"},{"_id":"6a8375e3af14b9c0e7b1f5e6","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Owoce, warzywa i ich przetwory","methodology":"Zawartość azotanów","parameters":[{"name":"NaNO3","range":"(10,20 - 9233,8) mg/kg"},{"name":"NO3−","range":"(7,43 - 8321,0) mg/kg"},{"name":"Zawartość azotynów NaNO2","range":"(1,30 - 1480) mg/kg"},{"name":"NO2−","range":"(0,89 - 1000,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotanów\nZakres:\nNaNO3 (10,20 - 9233,8) mg/kg\nNO3− (7,43 - 8321,0) mg/kg\nZawartość azotynów NaNO2 (1,30 - 1480) mg/kg\nNO2− (0,89 - 1000,0) mg/kg\nMetoda spektrofotometryczna","reference":"PN-A-75112:1992 pkt.3","norm_bases":["PN-A-75112:1992 pkt.3"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce, warzywa i ich przetwory Zawartość azotanów\nZakres:\nNaNO3 (10,20 - 9233,8) mg/kg\nNO3− (7,43 - 8321,0) mg/kg\nZawartość azotynów NaNO2 (1,30 - 1480) mg/kg\nNO2− (0,89 - 1000,0) mg/kg\nMetoda spektrofotometryczna PN-A-75112:1992 pkt.3 Owoce, warzywa i ich przetwory Zawartosc azotanow\nZakres:\nNaNO3 (10,20 - 9233,8) mg/kg\nNO3− (7,43 - 8321,0) mg/kg\nZawartosc azotynow NaNO2 (1,30 - 1480) mg/kg\nNO2− (0,89 - 1000,0) mg/kg\nMetoda spektrofotometryczna PN-A-75112:1992 pkt.3","categories":["other"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate content","parameters_en":[{"name":"NaNO3","range":"(10,20 - 9233,8) mg/kg"},{"name":"NO3−","range":"(7,43 - 8321,0) mg/kg"},{"name":"Nitrite content NaNO2","range":"(1,30 - 1480) mg/kg"},{"name":"NO2−","range":"(0,89 - 1000,0) mg/kg"}],"search_en":"Fruit, vegetables and their products Nitrate content Spectrophotometric method NaNO3 NO3− Nitrite content NaNO2 NO2− PN-A-75112:1992 pkt.3","technique_en":"Spectrophotometric method","test_object_en":"Fruit, vegetables and their products","search_zh":"水果、蔬菜及其制品 硝酸盐含量 分光光度法 NaNO3 PN-A-75112:1992 pkt.3","technique_zh":"分光光度法","methodology_zh":"硝酸盐含量","test_object_zh":"水果、蔬菜及其制品","parameters_zh":[{"name":"NaNO3","range":"(10,20 - 9233,8) mg/kg"},{"name":"NO3−","range":"(7,43 - 8321,0) mg/kg"},{"name":"Zawartość azotynów NaNO2","range":"(1,30 - 1480) mg/kg"},{"name":"NO2−","range":"(0,89 - 1000,0) mg/kg"}]},{"_id":"6a8375e3af14b9c0e7b1f5e7","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Owoce, warzywa i ich przetwory","methodology":"Zawartość dwutlenku siarki","parameters":[{"name":"Zakres","range":"(3,78 - 3000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość dwutlenku siarki\nZakres (3,78 - 3000) mg/kg\nMetoda miareczkowa","reference":"PN-A-75101-23: 1990 pkt.3 +Az2:2002","norm_bases":["PN-A-75101-23: 1990 pkt.3 +Az2:2002"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce, warzywa i ich przetwory Zawartość dwutlenku siarki\nZakres (3,78 - 3000) mg/kg\nMetoda miareczkowa PN-A-75101-23: 1990 pkt.3 +Az2:2002 Owoce, warzywa i ich przetwory Zawartosc dwutlenku siarki\nZakres (3,78 - 3000) mg/kg\nMetoda miareczkowa PN-A-75101-23: 1990 pkt.3 +Az2:2002","categories":["other"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Sulfur dioxide content","parameters_en":[{"name":"Range","range":"(3,78 - 3000) mg/kg"}],"search_en":"Fruit, vegetables and their products Sulfur dioxide content Titrimetric method Range PN-A-75101-23: 1990 pkt.3 +Az2:2002","technique_en":"Titrimetric method","test_object_en":"Fruit, vegetables and their products","parameters_zh":[{"name":"范围","range":"(3,78 - 3000) mg/kg"}],"search_zh":"水果、蔬菜及其制品 二氧化硫含量 滴定法 范围 PN-A-75101-23: 1990 pkt.3 +Az2:2002","technique_zh":"滴定法","methodology_zh":"二氧化硫含量","test_object_zh":"水果、蔬菜及其制品"},{"_id":"6a8375e3af14b9c0e7b1f5e8","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mleko i przetwory mleczne","methodology":"Zawartość azotanów","parameters":[{"name":"NO3−","range":"(3,44 - 540,0) mg/kg"},{"name":"NaNO3","range":"(4,71 - 739,8) mg/kg"},{"name":"Zawartość azotynów NO2−","range":"(0,31 - 80,0) mg/kg"},{"name":"NaNO2","range":"(0,46 - 118,4) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotanów\nZakres:\nNO3− (3,44 - 540,0) mg/kg\nNaNO3 (4,71 - 739,8) mg/kg\nZawartość azotynów NO2− (0,31 - 80,0) mg/kg\nNaNO2 (0,46 - 118,4) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN ISO 14673-1:2004+Ap1:2007","norm_bases":["PN-EN ISO 14673-1:2004+Ap1:2007"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i przetwory mleczne Zawartość azotanów\nZakres:\nNO3− (3,44 - 540,0) mg/kg\nNaNO3 (4,71 - 739,8) mg/kg\nZawartość azotynów NO2− (0,31 - 80,0) mg/kg\nNaNO2 (0,46 - 118,4) mg/kg\nMetoda spektrofotometryczna PN-EN ISO 14673-1:2004+Ap1:2007 Mleko i przetwory mleczne Zawartosc azotanow\nZakres:\nNO3− (3,44 - 540,0) mg/kg\nNaNO3 (4,71 - 739,8) mg/kg\nZawartosc azotynow NO2− (0,31 - 80,0) mg/kg\nNaNO2 (0,46 - 118,4) mg/kg\nMetoda spektrofotometryczna PN-EN ISO 14673-1:2004+Ap1:2007","categories":["food"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate content","parameters_en":[{"name":"NO3−","range":"(3,44 - 540,0) mg/kg"},{"name":"NaNO3","range":"(4,71 - 739,8) mg/kg"},{"name":"Nitrite content NO2−","range":"(0,31 - 80,0) mg/kg"},{"name":"NaNO2","range":"(0,46 - 118,4) mg/kg"}],"search_en":"Milk and milk products Nitrate content Spectrophotometric method NO3− NaNO3 Nitrite content NO2− NaNO2 PN-EN ISO 14673-1:2004+Ap1:2007","technique_en":"Spectrophotometric method","test_object_en":"Milk and milk products","search_zh":"乳与乳制品 硝酸盐含量 分光光度法 NaNO3 PN-EN ISO 14673-1:2004+Ap1:2007","technique_zh":"分光光度法","test_object_zh":"乳与乳制品","methodology_zh":"硝酸盐含量","parameters_zh":[{"name":"NO3−","range":"(3,44 - 540,0) mg/kg"},{"name":"NaNO3","range":"(4,71 - 739,8) mg/kg"},{"name":"Zawartość azotynów NO2−","range":"(0,31 - 80,0) mg/kg"},{"name":"NaNO2","range":"(0,46 - 118,4) mg/kg"}]},{"_id":"6a8375e3af14b9c0e7b1f5e9","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość azotanów","parameters":[{"name":"NaNO3","range":"(12,2 - 2197,5) mg/kg"},{"name":"NO3−","range":"(8,9 – 1604,2) mg/kg"},{"name":"Zawartość azotynów NaNO2","range":"(4,0 - 300,0) mg/kg"},{"name":"NO2−","range":"(2,7 - 201,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotanów\nZakres:\nNaNO3 (12,2 - 2197,5) mg/kg\nNO3− (8,9 – 1604,2) mg/kg\nZawartość azotynów NaNO2 (4,0 - 300,0) mg/kg\nNO2− (2,7 - 201,0) mg/kg\nMetoda spektrofotometryczna","reference":"PN-A-82114:1974","norm_bases":["PN-A-82114:1974"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość azotanów\nZakres:\nNaNO3 (12,2 - 2197,5) mg/kg\nNO3− (8,9 – 1604,2) mg/kg\nZawartość azotynów NaNO2 (4,0 - 300,0) mg/kg\nNO2− (2,7 - 201,0) mg/kg\nMetoda spektrofotometryczna PN-A-82114:1974 Mieso i przetwory miesne Zawartosc azotanow\nZakres:\nNaNO3 (12,2 - 2197,5) mg/kg\nNO3− (8,9 – 1604,2) mg/kg\nZawartosc azotynow NaNO2 (4,0 - 300,0) mg/kg\nNO2− (2,7 - 201,0) mg/kg\nMetoda spektrofotometryczna PN-A-82114:1974","categories":["food"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate content","parameters_en":[{"name":"NaNO3","range":"(12,2 - 2197,5) mg/kg"},{"name":"NO3−","range":"(8,9 – 1604,2) mg/kg"},{"name":"Nitrite content NaNO2","range":"(4,0 - 300,0) mg/kg"},{"name":"NO2−","range":"(2,7 - 201,0) mg/kg"}],"search_en":"Meat and meat products Nitrate content Spectrophotometric method NaNO3 NO3− Nitrite content NaNO2 NO2− PN-A-82114:1974","technique_en":"Spectrophotometric method","test_object_en":"Meat and meat products","search_zh":"肉与肉制品 硝酸盐含量 分光光度法 NaNO3 PN-A-82114:1974","technique_zh":"分光光度法","test_object_zh":"肉与肉制品","methodology_zh":"硝酸盐含量","parameters_zh":[{"name":"NaNO3","range":"(12,2 - 2197,5) mg/kg"},{"name":"NO3−","range":"(8,9 – 1604,2) mg/kg"},{"name":"Zawartość azotynów NaNO2","range":"(4,0 - 300,0) mg/kg"},{"name":"NO2−","range":"(2,7 - 201,0) mg/kg"}]},{"_id":"6a8375e3af14b9c0e7b1f5ea","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość fosforu ogólnego i dodanego","parameters":[{"name":"Zawartość fosforu ogólnego"},{"name":"Zakres","range":"(140 - 13000) mg/kg P2O5"},{"name":"Zawartość fosforu dodanego (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość fosforu ogólnego i dodanego\nZakres:\nZawartość fosforu ogólnego\nZakres (140 - 13000) mg/kg P2O5\nZawartość fosforu dodanego (z obliczeń)\nMetoda wagowa","reference":"PN-A-82060:1999","norm_bases":["PN-A-82060:1999"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość fosforu ogólnego i dodanego\nZakres:\nZawartość fosforu ogólnego\nZakres (140 - 13000) mg/kg P2O5\nZawartość fosforu dodanego (z obliczeń)\nMetoda wagowa PN-A-82060:1999 Mieso i przetwory miesne Zawartosc fosforu ogolnego i dodanego\nZakres:\nZawartosc fosforu ogolnego\nZakres (140 - 13000) mg/kg P2O5\nZawartosc fosforu dodanego (z obliczen)\nMetoda wagowa PN-A-82060:1999","categories":["food"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code","parameters_en":[{"name":"Total phosphorus content"},{"name":"Range","range":"(140 - 13000) mg/kg P2O5"},{"name":"Added phosphorus content (calculated)"}],"search_en":"Meat and meat products Gravimetric method Total phosphorus content Range Added phosphorus content (calculated) PN-A-82060:1999","technique_en":"Gravimetric method","test_object_en":"Meat and meat products","parameters_zh":[{"name":"总磷含量"},{"name":"范围","range":"(140 - 13000) mg/kg P2O5"},{"name":"添加磷含量（由计算得出）"}],"search_zh":"肉与肉制品 重量法 总磷含量 范围 添加磷含量（由计算得出） PN-A-82060:1999","technique_zh":"重量法","test_object_zh":"肉与肉制品"},{"_id":"6a8375e3af14b9c0e7b1f5eb","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Sól kuchenna","methodology":"Zawartość jodku potasowego","parameters":[{"name":"Zakres","range":"(12,83 - 173) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość jodku potasowego\nZakres (12,83 - 173) mg/kg\nMetoda miareczkowa","reference":"PN-C-84081-34:1980","norm_bases":["PN-C-84081-34:1980"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sól kuchenna Zawartość jodku potasowego\nZakres (12,83 - 173) mg/kg\nMetoda miareczkowa PN-C-84081-34:1980 Sol kuchenna Zawartosc jodku potasowego\nZakres (12,83 - 173) mg/kg\nMetoda miareczkowa PN-C-84081-34:1980","categories":["other"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Potassium iodide content","parameters_en":[{"name":"Range","range":"(12,83 - 173) mg/kg"}],"search_en":"Table salt Potassium iodide content Titrimetric method Range PN-C-84081-34:1980","technique_en":"Titrimetric method","test_object_en":"Table salt","parameters_zh":[{"name":"范围","range":"(12,83 - 173) mg/kg"}],"search_zh":"食盐 碘化钾含量 滴定法 范围 PN-C-84081-34:1980","technique_zh":"滴定法","methodology_zh":"碘化钾含量","test_object_zh":"食盐"},{"_id":"6a8375e3af14b9c0e7b1f5ec","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Ryby, owoce morza i ich przetwory, Przetwory zbożowo-mączne i wyroby ciastkarskie, Przetwory owocowo-warzywne, Tłuszcze roślinne i zwierzęce, Środki spożywcze specjalnego przeznaczenia, Koncentraty spożywcze, Suplementy diety, Wyroby garmażeryjne i kulinarne, Musztardy, sosy, Produkty mleczne, Napoje bezalkoholowe","methodology":"Zawartość kwasu benzoesowego, kwasu sorbowego,","parameters":[{"name":"Kwas benzoesowy"},{"name":"Zakres","range":"(10 - 10000) mg/l"},{"name":"Zakres","range":"(10 - 10000) mg/kg"},{"name":"Kwas sorbowy","range":"(15 - 10000 mg/l"},{"name":"(15 - 10000) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)"],"computed":[],"activity":"Zawartość kwasu benzoesowego, kwasu sorbowego,\nZakres:\nKwas benzoesowy\nZakres (10 - 10000) mg/l\nZakres (10 - 10000) mg/kg\nKwas sorbowy (15 - 10000 mg/l\n(15 - 10000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","reference":"PN-EN 12856:2002","norm_bases":["PN-EN 12856:2002"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby, owoce morza i ich przetwory, Przetwory zbożowo-mączne i wyroby ciastkarskie, Przetwory owocowo-warzywne, Tłuszcze roślinne i zwierzęce, Środki spożywcze specjalnego przeznaczenia, Koncentraty spożywcze, Suplementy diety, Wyroby garmażeryjne i kulinarne, Musztardy, sosy, Produkty mleczne, Napoje bezalkoholowe Zawartość kwasu benzoesowego, kwasu sorbowego,\nZakres:\nKwas benzoesowy\nZakres (10 - 10000) mg/l\nZakres (10 - 10000) mg/kg\nKwas sorbowy (15 - 10000 mg/l\n(15 - 10000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS) PN-EN 12856:2002 Ryby, owoce morza i ich przetwory, Przetwory zbozowo-maczne i wyroby ciastkarskie, Przetwory owocowo-warzywne, Tluszcze roslinne i zwierzece, Srodki spozywcze specjalnego przeznaczenia, Koncentraty spozywcze, Suplementy diety, Wyroby garmazeryjne i kulinarne, Musztardy, sosy, Produkty mleczne, Napoje bezalkoholowe Zawartosc kwasu benzoesowego, kwasu sorbowego,\nZakres:\nKwas benzoesowy\nZakres (10 - 10000) mg/l\nZakres (10 - 10000) mg/kg\nKwas sorbowy (15 - 10000 mg/l\n(15 - 10000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV-VIS) PN-EN 12856:2002","categories":["food","pharma"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Benzoic acid, sorbic acid content,","parameters_en":[{"name":"Benzoic acid"},{"name":"Range","range":"(10 - 10000) mg/l"},{"name":"Range","range":"(10 - 10000) mg/kg"},{"name":"Sorbic acid","range":"(15 - 10000 mg/l"},{"name":"(15 - 10000) mg/kg"}],"search_en":"Fish, seafood and their products, Cereal-flour products and pastry products, Fruit-vegetable products, Vegetable and animal fats, Foodstuffs for particular uses, Food concentrates, Food supplements, Delicatessen and culinary products, Mustards, sauces, Milk products, Non-alcoholic beverages Benzoic acid, sorbic acid content, High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS) Benzoic acid Range Range Sorbic acid PN-EN 12856:2002","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS)","test_object_en":"Fish, seafood and their products, Cereal-flour products and pastry products, Fruit-vegetable products, Vegetable and animal fats, Foodstuffs for particular uses, Food concentrates, Food supplements, Delicatessen and culinary products, Mustards, sauces, Milk products, Non-alcoholic beverages","parameters_zh":[{"name":"Kwas benzoesowy"},{"name":"范围","range":"(10 - 10000) mg/l"},{"name":"范围","range":"(10 - 10000) mg/kg"},{"name":"Kwas sorbowy","range":"(15 - 10000 mg/l"},{"name":"(15 - 10000) mg/kg"}],"search_zh":"高效液相色谱-分光光度检测法（HPLC-UV-VIS） 范围 范围 PN-EN 12856:2002","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV-VIS）"},{"_id":"6a8375e3af14b9c0e7b1f5ed","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Ryby, owoce morza i ich przetwory, Przetwory zbożowo-mączne i wyroby ciastkarskie, Przetwory owocowo-warzywne, Środki spożywcze specjalnego przeznaczenia, Koncentraty spożywcze, Suplementy diety, Wyroby garmażeryjne i kulinarne, Musztardy, sosy, Produkty mleczne, Napoje bezalkoholowe","methodology":"Zawartość aspartamu, acesulfamu-K, sacharyny","parameters":[{"name":"Aspartam"},{"name":"Zakres","range":"(25 - 10000) mg/l"},{"name":"Zakres","range":"(25 - 10000) mg/kg"},{"name":"Acesulfam-K","range":"(10 - 10000) mg/l"},{"name":"(10 - 10000) mg/kg"},{"name":"Sacharyna","range":"(5 - 10000) mg/l"},{"name":"(5 - 10000) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)"],"computed":[],"activity":"Zawartość aspartamu, acesulfamu-K, sacharyny\nZakres:\nAspartam\nZakres (25 - 10000) mg/l\nZakres (25 - 10000) mg/kg\nAcesulfam-K (10 - 10000) mg/l\n(10 - 10000) mg/kg\nSacharyna (5 - 10000) mg/l\n(5 - 10000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","reference":"PN-EN 12856:2002","norm_bases":["PN-EN 12856:2002"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby, owoce morza i ich przetwory, Przetwory zbożowo-mączne i wyroby ciastkarskie, Przetwory owocowo-warzywne, Środki spożywcze specjalnego przeznaczenia, Koncentraty spożywcze, Suplementy diety, Wyroby garmażeryjne i kulinarne, Musztardy, sosy, Produkty mleczne, Napoje bezalkoholowe Zawartość aspartamu, acesulfamu-K, sacharyny\nZakres:\nAspartam\nZakres (25 - 10000) mg/l\nZakres (25 - 10000) mg/kg\nAcesulfam-K (10 - 10000) mg/l\n(10 - 10000) mg/kg\nSacharyna (5 - 10000) mg/l\n(5 - 10000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS) PN-EN 12856:2002 Ryby, owoce morza i ich przetwory, Przetwory zbozowo-maczne i wyroby ciastkarskie, Przetwory owocowo-warzywne, Srodki spozywcze specjalnego przeznaczenia, Koncentraty spozywcze, Suplementy diety, Wyroby garmazeryjne i kulinarne, Musztardy, sosy, Produkty mleczne, Napoje bezalkoholowe Zawartosc aspartamu, acesulfamu-K, sacharyny\nZakres:\nAspartam\nZakres (25 - 10000) mg/l\nZakres (25 - 10000) mg/kg\nAcesulfam-K (10 - 10000) mg/l\n(10 - 10000) mg/kg\nSacharyna (5 - 10000) mg/l\n(5 - 10000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV-VIS) PN-EN 12856:2002","categories":["food","pharma"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aspartame, acesulfame-K, saccharin content","parameters_en":[{"name":"Aspartame"},{"name":"Range","range":"(25 - 10000) mg/l"},{"name":"Range","range":"(25 - 10000) mg/kg"},{"name":"Acesulfame-K","range":"(10 - 10000) mg/l"},{"name":"(10 - 10000) mg/kg"},{"name":"Saccharin","range":"(5 - 10000) mg/l"},{"name":"(5 - 10000) mg/kg"}],"search_en":"Fish, seafood and their products, Cereal-flour products and pastry products, Fruit-vegetable products, Foodstuffs for particular uses, Food concentrates, Food supplements, Delicatessen and culinary products, Mustards, sauces, Milk products, Non-alcoholic beverages Aspartame, acesulfame-K, saccharin content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS) Aspartame Range Range Acesulfame-K (10 - 10000) mg/kg Saccharin (5 - 10000) mg/kg PN-EN 12856:2002","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS)","test_object_en":"Fish, seafood and their products, Cereal-flour products and pastry products, Fruit-vegetable products, Foodstuffs for particular uses, Food concentrates, Food supplements, Delicatessen and culinary products, Mustards, sauces, Milk products, Non-alcoholic beverages","parameters_zh":[{"name":"Aspartam"},{"name":"范围","range":"(25 - 10000) mg/l"},{"name":"范围","range":"(25 - 10000) mg/kg"},{"name":"Acesulfam-K","range":"(10 - 10000) mg/l"},{"name":"(10 - 10000) mg/kg"},{"name":"Sacharyna","range":"(5 - 10000) mg/l"},{"name":"(5 - 10000) mg/kg"}],"search_zh":"高效液相色谱-分光光度检测法（HPLC-UV-VIS） 范围 范围 PN-EN 12856:2002","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV-VIS）"},{"_id":"6a8375e3af14b9c0e7b1f5ee","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Przetwory zbożowo-mączne i wyroby ciastkarskie, Środki spożywcze specjalnego przeznaczenia, Koncentraty spożywcze, Suplementy diety, Wyroby garmażeryjne i kulinarne, Produkty mleczne, Napoje bezalkoholowe","methodology":"Zawartość kofeiny","parameters":[{"name":"Zakres","range":"(10 - 10000) mg/l"},{"name":"Zakres","range":"(10 - 30000) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)"],"computed":[],"activity":"Zawartość kofeiny\nZakres:\nZakres (10 - 10000) mg/l\nZakres (10 - 30000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","reference":"PN-EN 12856:2002","norm_bases":["PN-EN 12856:2002"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory zbożowo-mączne i wyroby ciastkarskie, Środki spożywcze specjalnego przeznaczenia, Koncentraty spożywcze, Suplementy diety, Wyroby garmażeryjne i kulinarne, Produkty mleczne, Napoje bezalkoholowe Zawartość kofeiny\nZakres:\nZakres (10 - 10000) mg/l\nZakres (10 - 30000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS) PN-EN 12856:2002 Przetwory zbozowo-maczne i wyroby ciastkarskie, Srodki spozywcze specjalnego przeznaczenia, Koncentraty spozywcze, Suplementy diety, Wyroby garmazeryjne i kulinarne, Produkty mleczne, Napoje bezalkoholowe Zawartosc kofeiny\nZakres:\nZakres (10 - 10000) mg/l\nZakres (10 - 30000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV-VIS) PN-EN 12856:2002","categories":["food","pharma"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Caffeine content","parameters_en":[{"name":"Range","range":"(10 - 10000) mg/l"},{"name":"Range","range":"(10 - 30000) mg/kg"}],"search_en":"Cereal-flour products and pastry products, Foodstuffs for particular uses, Food concentrates, Food supplements, Delicatessen and culinary products, Milk products, Non-alcoholic beverages Caffeine content High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS) Range Range PN-EN 12856:2002","technique_en":"High-performance liquid chromatography with spectrophotometric detection (HPLC-UV-VIS)","test_object_en":"Cereal-flour products and pastry products, Foodstuffs for particular uses, Food concentrates, Food supplements, Delicatessen and culinary products, Milk products, Non-alcoholic beverages","parameters_zh":[{"name":"范围","range":"(10 - 10000) mg/l"},{"name":"范围","range":"(10 - 30000) mg/kg"}],"search_zh":"咖啡因含量 高效液相色谱-分光光度检测法（HPLC-UV-VIS） 范围 范围 PN-EN 12856:2002","methodology_zh":"咖啡因含量","technique_zh":"高效液相色谱-分光光度检测法（HPLC-UV-VIS）"},{"_id":"6a8375e3af14b9c0e7b1f5ef","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Napoje spirytusowe","methodology":"Zawartość cyjanowodoru","parameters":[{"name":"Zakres","range":"(0,0088 - 13) g/hl 100% alkoholu etylowego"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość cyjanowodoru\nZakres (0,0088 - 13) g/hl 100% alkoholu etylowego\nMetoda spektrofotometryczna","reference":"PN-A-79529-13:2005 pkt. 5.3","norm_bases":["PN-A-79529-13:2005 pkt. 5.3"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje spirytusowe Zawartość cyjanowodoru\nZakres (0,0088 - 13) g/hl 100% alkoholu etylowego\nMetoda spektrofotometryczna PN-A-79529-13:2005 pkt. 5.3 Napoje spirytusowe Zawartosc cyjanowodoru\nZakres (0,0088 - 13) g/hl 100% alkoholu etylowego\nMetoda spektrofotometryczna PN-A-79529-13:2005 pkt. 5.3","categories":["food"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Hydrogen cyanide content","parameters_en":[{"name":"Range","range":"(0,0088 - 13) g/hl 100% alkoholu etylowego"}],"search_en":"Spirit drinks Hydrogen cyanide content Spectrophotometric method Range PN-A-79529-13:2005 pkt. 5.3","technique_en":"Spectrophotometric method","test_object_en":"Spirit drinks","parameters_zh":[{"name":"范围","range":"(0,0088 - 13) g/hl 100% alkoholu etylowego"}],"search_zh":"烈性酒 氰化氢含量 分光光度法 范围 PN-A-79529-13:2005 pkt. 5.3","technique_zh":"分光光度法","test_object_zh":"烈性酒","methodology_zh":"氰化氢含量"},{"_id":"6a8375e3af14b9c0e7b1f5f0","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalni) pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 - 10,0)"}],"search_en":"Water (including swimming pool water) pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 - 10,0)"}],"search_zh":"水（含游泳池水） pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5f1","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(30 - 750) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (30 - 750) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie żelaza ogólnego\nZakres (30 - 750) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda (w tym woda na plywalni) Stezenie zelaza ogolnego\nZakres (30 - 750) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(30 - 750) μg/l"}],"search_en":"Water (including swimming pool water) Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(30 - 750) μg/l"}],"search_zh":"水（含游泳池水） 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5f2","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1,00 - 110) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (1,00 - 110) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-08:1982","norm_bases":["PN-C-04576-08:1982"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie azotanów\nZakres (1,00 - 110) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982 Woda (w tym woda na plywalni) Stezenie azotanow\nZakres (1,00 - 110) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982","categories":["water"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(1,00 - 110) mg/l"}],"search_en":"Water (including swimming pool water) Nitrate concentration Spectrophotometric method Range PN-C-04576-08:1982","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,00 - 110) mg/l"}],"search_zh":"水（含游泳池水） 硝酸盐浓度 分光光度法 范围 PN-C-04576-08:1982","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5f3","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(88 - 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (88 - 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Przewodność elektryczna właściwa\nZakres (88 - 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda (w tym woda na plywalni) Przewodnosc elektryczna wlasciwa\nZakres (88 - 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(88 - 3000) μS/cm"}],"search_en":"Water (including swimming pool water) Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(88 - 3000) μS/cm"}],"search_zh":"水（含游泳池水） 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5f4","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,070 - 1,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,070 - 1,50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie jonu amonowego\nZakres (0,070 - 1,50) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda (w tym woda na plywalni) Stezenie jonu amonowego\nZakres (0,070 - 1,50) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,070 - 1,50) mg/l"}],"search_en":"Water (including swimming pool water) Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,070 - 1,50) mg/l"}],"search_zh":"水（含游泳池水） 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5f5","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 - 680) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 - 680) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie chlorków\nZakres (5,00 - 680) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda (w tym woda na plywalni) Stezenie chlorkow\nZakres (5,00 - 680) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,00 - 680) mg/l"}],"search_en":"Water (including swimming pool water) Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 - 680) mg/l"}],"search_zh":"水（含游泳池水） 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5f6","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 - 40) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 - 40) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Barwa\nZakres (5 - 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C Woda (w tym woda na plywalni) Barwa\nZakres (5 - 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","categories":["water"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 - 40) mg/l Pt"}],"search_en":"Water (including swimming pool water) Colour Spectrophotometric method Range PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water (including swimming pool water)","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 - 40) mg/l Pt"}],"search_zh":"水（含游泳池水） 色度 分光光度法 范围 PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"水（含游泳池水）"},{"_id":"6a8375e3af14b9c0e7b1f5f7","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"pH","parameters_en":[{"name":"Range","range":"(4,0 - 10,0)"}],"search_en":"Water intended for human consumption pH Potentiometric method Range PN-EN ISO 10523:2012","technique_en":"Potentiometric method","test_object_en":"Water intended for human consumption","methodology_zh":"pH 值","parameters_zh":[{"name":"范围","range":"(4,0 - 10,0)"}],"search_zh":"生活饮用水 pH 值 电位法 范围 PN-EN ISO 10523:2012","technique_zh":"电位法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5f8","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(30 – 8000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (30 – 8000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (30 – 8000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (30 – 8000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Total iron concentration","parameters_en":[{"name":"Range","range":"(30 – 8000) μg/l"}],"search_en":"Water intended for human consumption Total iron concentration Spectrophotometric method Range PN-ISO 6332:2001+Ap1:2016-06","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"总铁浓度","parameters_zh":[{"name":"范围","range":"(30 – 8000) μg/l"}],"search_zh":"生活饮用水 总铁浓度 分光光度法 范围 PN-ISO 6332:2001+Ap1:2016-06","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5f9","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1,00 - 110) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (1,00 - 110) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-08:1982","norm_bases":["PN-C-04576-08:1982"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (1,00 - 110) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (1,00 - 110) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982","categories":["water"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Nitrate concentration","parameters_en":[{"name":"Range","range":"(1,00 - 110) mg/l"}],"search_en":"Water intended for human consumption Nitrate concentration Spectrophotometric method Range PN-C-04576-08:1982","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"硝酸盐浓度","parameters_zh":[{"name":"范围","range":"(1,00 - 110) mg/l"}],"search_zh":"生活饮用水 硝酸盐浓度 分光光度法 范围 PN-C-04576-08:1982","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5fa","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 - 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Turbidity","parameters_en":[{"name":"Range","range":"(0,10 - 100) NTU"}],"search_en":"Water intended for human consumption Turbidity Nephelometric method Range PN-EN ISO 7027-1:2016-09","technique_en":"Nephelometric method","test_object_en":"Water intended for human consumption","methodology_zh":"浊度","parameters_zh":[{"name":"范围","range":"(0,10 - 100) NTU"}],"search_zh":"生活饮用水 浊度 浊度法（散射法） 范围 PN-EN ISO 7027-1:2016-09","technique_zh":"浊度法（散射法）","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5fb","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie glinu/aluminium","parameters":[{"name":"Zakres","range":"(40 - 1000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu/aluminium\nZakres (40 - 1000) μg/l\nMetoda spektrofotometryczna","reference":"PN-C-04605-02:1992","norm_bases":["PN-C-04605-02:1992"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie glinu/aluminium\nZakres (40 - 1000) μg/l\nMetoda spektrofotometryczna PN-C-04605-02:1992 Woda do spozycia przez ludzi Stezenie glinu/aluminium\nZakres (40 - 1000) μg/l\nMetoda spektrofotometryczna PN-C-04605-02:1992","categories":["water","materials"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Aluminium concentration","parameters_en":[{"name":"Range","range":"(40 - 1000) μg/l"}],"search_en":"Water intended for human consumption Aluminium concentration Spectrophotometric method Range PN-C-04605-02:1992","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(40 - 1000) μg/l"}],"search_zh":"生活饮用水 分光光度法 范围 PN-C-04605-02:1992","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5fc","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(88 - 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (88 - 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (88 - 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (88 - 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Electrical conductivity","parameters_en":[{"name":"Range","range":"(88 - 3000) μS/cm"}],"search_en":"Water intended for human consumption Electrical conductivity Conductometric method Range PN-EN 27888:1999","technique_en":"Conductometric method","test_object_en":"Water intended for human consumption","methodology_zh":"电导率","parameters_zh":[{"name":"范围","range":"(88 - 3000) μS/cm"}],"search_zh":"生活饮用水 电导率 电导法 范围 PN-EN 27888:1999","technique_zh":"电导法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5fd","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,070 - 1,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,070 - 1,50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,070 - 1,50) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,070 - 1,50) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Ammonium ion concentration","parameters_en":[{"name":"Range","range":"(0,070 - 1,50) mg/l"}],"search_en":"Water intended for human consumption Ammonium ion concentration Spectrophotometric method Range PN-ISO 7150-1:2002","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"铵离子浓度","parameters_zh":[{"name":"范围","range":"(0,070 - 1,50) mg/l"}],"search_zh":"生活饮用水 铵离子浓度 分光光度法 范围 PN-ISO 7150-1:2002","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5fe","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 - 680) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 - 680) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,00 - 680) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,00 - 680) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Chloride concentration","parameters_en":[{"name":"Range","range":"(5,00 - 680) mg/l"}],"search_en":"Water intended for human consumption Chloride concentration Titrimetric method Range PN-ISO 9297:1994","technique_en":"Titrimetric method","test_object_en":"Water intended for human consumption","methodology_zh":"氯化物浓度","parameters_zh":[{"name":"范围","range":"(5,00 - 680) mg/l"}],"search_zh":"生活饮用水 氯化物浓度 滴定法 范围 PN-ISO 9297:1994","technique_zh":"滴定法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f5ff","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 - 40) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 - 40) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 - 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (5 - 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","categories":["water"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Colour","parameters_en":[{"name":"Range","range":"(5 - 40) mg/l Pt"}],"search_en":"Water intended for human consumption Colour Spectrophotometric method Range PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","methodology_zh":"色度","parameters_zh":[{"name":"范围","range":"(5 - 40) mg/l Pt"}],"search_zh":"生活饮用水 色度 分光光度法 范围 PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","technique_zh":"分光光度法","test_object_zh":"生活饮用水"},{"_id":"6a8375e3af14b9c0e7b1f600","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,040 - 1,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,040 - 1,60) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie ortofosforanów\nZakres (0,040 - 1,60) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 Woda do spozycia przez ludzi Stezenie ortofosforanow\nZakres (0,040 - 1,60) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Orthophosphate concentration","parameters_en":[{"name":"Range","range":"(0,040 - 1,60) mg/l"}],"search_en":"Water intended for human consumption Orthophosphate concentration Spectrophotometric method Range PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","technique_en":"Spectrophotometric method","test_object_en":"Water intended for human consumption","parameters_zh":[{"name":"范围","range":"(0,040 - 1,60) mg/l"}],"search_zh":"生活饮用水 正磷酸盐浓度 分光光度法 范围 PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","technique_zh":"分光光度法","test_object_zh":"生活饮用水","methodology_zh":"正磷酸盐浓度"},{"_id":"6a8375e3af14b9c0e7b1f601","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Woda E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["water","microbiology"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Water E Presence of microorganisms Culture method with biochemical and serological confirmation Normy","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Water E","search_zh":"水 E 微生物的检出 培养法结合生化与血清学确认 Normy","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"水 E","methodology_zh":"微生物的检出"},{"_id":"6a8375e3af14b9c0e7b1f602","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda filtracji membranowej Normy Woda E Liczba drobnoustrojow\nMetoda filtracji membranowej Normy","categories":["water","microbiology"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Water E Microorganism count Membrane filtration method Normy","technique_en":"Membrane filtration method","test_object_en":"Water E","methodology_zh":"菌落总数","search_zh":"水 E 菌落总数 膜过滤法 Normy","technique_zh":"膜过滤法","test_object_zh":"水 E"},{"_id":"6a8375e3af14b9c0e7b1f603","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Woda E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["water","microbiology"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Water E Microorganism count Plate method (pour plate) Normy","technique_en":"Plate method (pour plate)","test_object_en":"Water E","methodology_zh":"菌落总数","search_zh":"水 E 菌落总数 平板法（倾注培养） Normy","technique_zh":"平板法（倾注培养）","test_object_zh":"水 E"},{"_id":"6a8375e3af14b9c0e7b1f604","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda zminiaturyzowana, NPL","techniques":["Metoda zminiaturyzowana, NPL"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda zminiaturyzowana, NPL","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda zminiaturyzowana, NPL Normy Woda E Liczba drobnoustrojow\nMetoda zminiaturyzowana, NPL Normy","categories":["water","microbiology"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Water E Microorganism count Miniaturized method, MPN Normy","technique_en":"Miniaturized method, MPN","test_object_en":"Water E","methodology_zh":"菌落总数","search_zh":"水 E 菌落总数 Normy","test_object_zh":"水 E"},{"_id":"6a8375e3af14b9c0e7b1f605","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["food","microbiology"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Food E Presence of microorganisms Culture method with biochemical and serological confirmation Normy","technique_en":"Culture method with biochemical and serological confirmation","test_object_en":"Food E","search_zh":"食品 E 微生物的检出 培养法结合生化与血清学确认 Normy","technique_zh":"培养法结合生化与血清学确认","test_object_zh":"食品 E","methodology_zh":"微生物的检出"},{"_id":"6a8375e3af14b9c0e7b1f606","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy","categories":["food","microbiology"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Presence of microorganisms","search_en":"Food E Presence of microorganisms Culture method with biochemical confirmation Normy","technique_en":"Culture method with biochemical confirmation","test_object_en":"Food E","search_zh":"食品 E 微生物的检出 培养法结合生化确认 Normy","technique_zh":"培养法结合生化确认","test_object_zh":"食品 E","methodology_zh":"微生物的检出"},{"_id":"6a8375e3af14b9c0e7b1f607","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Zywnosc E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["food","microbiology"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Food E Microorganism count Plate method (pour plate) Normy","technique_en":"Plate method (pour plate)","test_object_en":"Food E","methodology_zh":"菌落总数","search_zh":"食品 E 菌落总数 平板法（倾注培养） Normy","technique_zh":"平板法（倾注培养）","test_object_zh":"食品 E"},{"_id":"6a8375e3af14b9c0e7b1f608","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Zywnosc E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy","categories":["food","microbiology"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code","methodology_en":"Microorganism count","search_en":"Food E Microorganism count Plate method (spread plate) Normy","technique_en":"Plate method (spread plate)","test_object_en":"Food E","methodology_zh":"菌落总数","search_zh":"食品 E 菌落总数 平板法（表面涂布） Normy","technique_zh":"平板法（表面涂布）","test_object_zh":"食品 E"}],"has_pdf":true}