{"lab":{"_id":"69ad52a3de79e566650fb312","accr_number":"AB 601","country":"PL","accr_body":"PCA","address":"W KRAKOWIE, ul. Prądnicka 76, 31-202 Kraków","categories":["water","food","microbiology","materials","pharma"],"city":"Kraków","imported_at":"2026-03-08T10:42:43.265Z","methods_count":179,"name":"WOJEWÓDZKA STACJA SANITARNO-EPIDEMIOLOGICZNA","parse_status":"parsed","parse_version":3,"pdf_files":["AB_601.pdf"],"scope_summary":"","search_text":"wojewódzka stacja sanitarno-epidemiologiczna w krakowie, ul. prądnicka 76, 31-202 kraków materials food pharma other petro metrology water microbiology electronics automotive environment","status":"active","updated_at":"2026-03-08T14:51:29.980Z","valid_from":"","valid_until":"","website":"","parsed_at":"2026-09-04T00:54:52.678Z","location":{"type":"Point","coordinates":[19.945,50.0647]},"email_confidence":"high","email_mx":true,"email_source":"https://www.pca.gov.pl/akredytowane-podmioty/akredytacje-aktywne/laboratoria-badawcze/AB%20601,podmiot.html","fields_of_testing":[{"codes":"C/12; C/21; C/22; C/28; C/29; C/42","pl":"przez ludzi, kosmetyków","en":"Chemical tests of glass and ceramics, plastic products, food, water, drinking water, cosmetics Badania dotyczące inżynierii środowiska (środowiskowe i klimatyczne) – środowisko pracy (czynniki"},{"codes":"G/33","pl":"szkodliwe – pole elektromagnetyczne)","en":"Tests concerning environmental engineering (environmental and climatic) – working environment (harmful factors – electromagnetic field) Badania mikrobiologiczne obiektów i materiałów biologicznych przeznaczonych do badań, żywności, wody,"},{"codes":"K/3; K/22; K/28; K/29; K/42; K/57","pl":"wody do spożycia przez ludzi, kosmetyków, obiektów z obszaru produkcji żywności","en":"Microbiological tests of biological items and materials for testing, food, water, drinking water, cosmetics, objects from food production area Badania właściwości fizycznych wyposażenia medycznego - urządzenia radiologiczne, wody, wody do"},{"codes":"N/14; N/28; N/29","pl":"spożycia przez ludzi","en":"Tests of physical properties of medical equipment, water, drinking water Badania radiochemiczne i promieniowania - w tym nuklearne produktów rolnych, żywności, wody, wody do"},{"codes":"O/1; O/22; O/28; O/29; O/55","pl":"spożycia przez ludzi, paszy","en":"Radiochemical tests and tests of radiation – including nuclear radiation of agricultural products, food, water, drinking water, animal feedstuffs"}],"issue":{"no":"25","date":"22.04.2026"},"parse_date":"2026-09-04T00:54:52.678Z","parse_source":"agent-claude-code","map_coord":[50.087156,19.937902],"map_geo":"nominatim-street","lab_locations":[{"code":null,"name":"WOJEWÓDZKA STACJA SANITARNO-EPIDEMIOLOGICZNA","street":"ul. Prądnicka 76","postal_code":"31-202","city":"Kraków","is_hq":true,"address":"ul. Prądnicka 76, 31-202 Kraków","site":"31-202|prądnicka76"},{"code":null,"name":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","street":"ul. Prądnicka 76","postal_code":"31-202","city":"Kraków","is_hq":false,"address":"ul. Prądnicka 76, 31-202 Kraków","site":"31-202|prądnicka76"},{"code":null,"name":"ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","street":"ul. Prądnicka 76","postal_code":"31-202","city":"Kraków","is_hq":false,"address":"ul. Prądnicka 76, 31-202 Kraków","site":"31-202|prądnicka76"},{"code":null,"name":"ODDZIAŁ LABORATORYJNY BADANIA WODY","street":"ul. Prądnicka 76","postal_code":"31-202","city":"Kraków","is_hq":false,"address":"ul. Prądnicka 76, 31-202 Kraków","site":"31-202|prądnicka76"},{"code":null,"name":"Dział Laboratoryjny – obszar higieny radiacyjnej","street":"ul. Prądnicka 76","postal_code":"31-202","city":"Kraków","is_hq":false,"address":"ul. Prądnicka 76, 31-202 Kraków","site":"31-202|prądnicka76"},{"code":null,"name":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","street":"ul. Prądnicka 76","postal_code":"31-202","city":"Kraków","is_hq":false,"address":"ul. Prądnicka 76, 31-202 Kraków","site":"31-202|prądnicka76"},{"code":null,"name":"Oddział Laboratoryjny w Tarnowie","street":"ul. Ignacego Mościckiego 10","postal_code":"33-100","city":"Tarnów","is_hq":false,"address":"ul. Ignacego Mościckiego 10, 33-100 Tarnów","site":"33-100|ignacegomościckiego10"},{"code":null,"name":"ODDZIAŁ LABORATORYJNY w WADOWICACH","street":"ul. Teatralna 2","postal_code":"34-100","city":"Wadowice","is_hq":false,"address":"ul. Teatralna 2, 34-100 Wadowice","site":"34-100|teatralna2"}],"scope_format":"PCA::pracownie+elastyczny+siatka4","source_pdf_url":"https://bip.pca.gov.pl/storage/file/e-accreditations/2026/9/3/c1a02c9889b57e46af6837b8816b5b92/AB%20601.pdf","has_en":true,"category_counts":{"water":112,"food":46,"microbiology":36,"other":15,"materials":12,"pharma":6,"environment":4,"petro":1},"category_scores":{"water":54.07,"food":9.12,"microbiology":5.59,"other":0.97,"materials":0.62,"pharma":0.16,"environment":0.07,"petro":0},"has_zh":true},"methods":[{"_id":"6a9a16dd9dc807729a5d31ec","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość metali i innych pierwiastków","parameters":[],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Zawartość metali i innych pierwiastków\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"Procedury opracowane przez laboratorium Normy","norm_bases":["Procedury opracowane przez laboratorium Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość metali i innych pierwiastków\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) Procedury opracowane przez laboratorium Normy Zywnosc E Zawartosc metali i innych pierwiastkow\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) Procedury opracowane przez laboratorium Normy","categories":["materials","food"],"row_index":0,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31ed","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość metali i innych pierwiastków","parameters":[],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HG AAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HG AAS)"],"computed":[],"activity":"Zawartość metali i innych pierwiastków\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HG AAS)","reference":"Procedury opracowane przez laboratorium Normy","norm_bases":["Procedury opracowane przez laboratorium Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość metali i innych pierwiastków\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorków (HG AAS) Procedury opracowane przez laboratorium Normy Zywnosc E Zawartosc metali i innych pierwiastkow\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem wodorkow (HG AAS) Procedury opracowane przez laboratorium Normy","categories":["materials","food"],"row_index":1,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31ee","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość rtęci","parameters":[],"technique":"Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CV AAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CV AAS)"],"computed":[],"activity":"Zawartość rtęci\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CV AAS)","reference":"PB-LZ/LI-03","norm_bases":["PB-LZ/LI-03"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość rtęci\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CV AAS) PB-LZ/LI-03 Zywnosc E Zawartosc rteci\nMetoda absorpcyjnej spektrometrii atomowej z generowaniem zimnych par (CV AAS) PB-LZ/LI-03","categories":["food"],"row_index":2,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31ef","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość metali i innych pierwiastków","parameters":[],"technique":"Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ET AAS)","techniques":["Metoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ET AAS)"],"computed":[],"activity":"Zawartość metali i innych pierwiastków\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ET AAS)","reference":"Procedury opracowane przez laboratorium Normy","norm_bases":["Procedury opracowane przez laboratorium Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość metali i innych pierwiastków\nMetoda absorpcyjnej spektrometrii atomowej z atomizacją elektrotermiczną (ET AAS) Procedury opracowane przez laboratorium Normy Zywnosc E Zawartosc metali i innych pierwiastkow\nMetoda absorpcyjnej spektrometrii atomowej z atomizacja elektrotermiczna (ET AAS) Procedury opracowane przez laboratorium Normy","categories":["materials","food"],"row_index":3,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31f0","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość mikotoksyn","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"Procedury opracowane przez laboratorium Normy","norm_bases":["Procedury opracowane przez laboratorium Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) Procedury opracowane przez laboratorium Normy Zywnosc E Zawartosc mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) Procedury opracowane przez laboratorium Normy","categories":["food"],"row_index":4,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31f1","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość mikotoksyn","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Procedury opracowane przez laboratorium Normy","norm_bases":["Procedury opracowane przez laboratorium Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Procedury opracowane przez laboratorium Normy Zywnosc E Zawartosc mikotoksyn\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Procedury opracowane przez laboratorium Normy","categories":["food"],"row_index":5,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31f2","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"Procedury opracowane przez laboratorium","norm_bases":["Procedury opracowane przez laboratorium"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość wielopierścieniowych węglowodorów aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) Procedury opracowane przez laboratorium Zywnosc E Zawartosc wielopierscieniowych weglowodorow aromatycznych (WWA)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) Procedury opracowane przez laboratorium","categories":["food"],"row_index":6,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31f3","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość barwników","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość barwników\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"Procedury opracowane przez laboratorium","norm_bases":["Procedury opracowane przez laboratorium"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość barwników\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) Procedury opracowane przez laboratorium Zywnosc E Zawartosc barwnikow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) Procedury opracowane przez laboratorium","categories":["food"],"row_index":7,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31f4","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość środków słodzących","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość środków słodzących\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość środków słodzących\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) Normy Zywnosc E Zawartosc srodkow slodzacych\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) Normy","categories":["food"],"row_index":8,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31f5","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość konserwantów","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość konserwantów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość konserwantów\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) Normy Zywnosc E Zawartosc konserwantow\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) Normy","categories":["food"],"row_index":9,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31f6","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość kofeiny","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość kofeiny\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość kofeiny\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) Normy Zywnosc E Zawartosc kofeiny\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) Normy","categories":["food"],"row_index":10,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31f7","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość witamin","parameters":[],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"Procedury opracowane przez laboratorium","norm_bases":["Procedury opracowane przez laboratorium"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) Procedury opracowane przez laboratorium Zywnosc E Zawartosc witamin\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) Procedury opracowane przez laboratorium","categories":["food"],"row_index":11,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31f8","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość kwasów tłuszczowych","parameters":[],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość kwasów tłuszczowych\nMetoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID)","reference":"PB-LI-26","norm_bases":["PB-LI-26"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość kwasów tłuszczowych\nMetoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID) PB-LI-26 Zywnosc E Zawartosc kwasow tluszczowych\nMetoda chromatografii gazowej z detekcja plomieniowo- jonizacyjna (GC-FID) PB-LI-26","categories":["food"],"row_index":12,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31f9","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Wyroby ceramiczne i powierzchnie krzemianowe wyrobów innych niż ceramiczne przeznaczone do kontaktu z żywnością","methodology":"Migracja metali: ołowiu i kadmu Ołów","parameters":[{"name":"Zakres","range":"(0,2 -100,0) mg/dm3"},{"name":"Zakres","range":"(0,02 - 10,0) mg/dm2"},{"name":"Zakres","range":"(0,02 – 10,0) mg/obrzeże"},{"name":"Kadm"},{"name":"Zakres","range":"(0,02 - 5,0) mg/dm3"},{"name":"Zakres","range":"(0,002 - 0,5) mg/dm2"},{"name":"Zakres","range":"(0,002 – 0,5) mg/obrzeże"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Migracja metali: ołowiu i kadmu Ołów\nZakres:\nZakres (0,2 -100,0) mg/dm3\nZakres (0,02 - 10,0) mg/dm2\nZakres (0,02 – 10,0) mg/obrzeże\nKadm\nZakres (0,02 - 5,0) mg/dm3\nZakres (0,002 - 0,5) mg/dm2\nZakres (0,002 – 0,5) mg/obrzeże\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-EN 1388-1:2000+Ap1:2002 | PN-EN 1388-2:2000","norm_bases":["PN-EN 1388-1:2000+Ap1:2002","PN-EN 1388-2:2000"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby ceramiczne i powierzchnie krzemianowe wyrobów innych niż ceramiczne przeznaczone do kontaktu z żywnością Migracja metali: ołowiu i kadmu Ołów\nZakres:\nZakres (0,2 -100,0) mg/dm3\nZakres (0,02 - 10,0) mg/dm2\nZakres (0,02 – 10,0) mg/obrzeże\nKadm\nZakres (0,02 - 5,0) mg/dm3\nZakres (0,002 - 0,5) mg/dm2\nZakres (0,002 – 0,5) mg/obrzeże\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1388-1:2000+Ap1:2002 | PN-EN 1388-2:2000 Wyroby ceramiczne i powierzchnie krzemianowe wyrobow innych niz ceramiczne przeznaczone do kontaktu z zywnoscia Migracja metali: olowiu i kadmu Olow\nZakres:\nZakres (0,2 -100,0) mg/dm3\nZakres (0,02 - 10,0) mg/dm2\nZakres (0,02 – 10,0) mg/obrzeze\nKadm\nZakres (0,02 - 5,0) mg/dm3\nZakres (0,002 - 0,5) mg/dm2\nZakres (0,002 – 0,5) mg/obrzeze\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-EN 1388-1:2000+Ap1:2002 | PN-EN 1388-2:2000","categories":["materials","food"],"row_index":13,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31fa","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kosmetyki – pasty do zębów","methodology":"Zawartość fluoru","parameters":[{"name":"Zakres","range":"(0,03 - 0,23) %"}],"technique":"Metoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID)","techniques":["Metoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID)"],"computed":[],"activity":"Zawartość fluoru\nZakres (0,03 - 0,23) %\nMetoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID)","reference":"PB-LI-31 wydanie nr 6 z dnia 01.12.2025 r.","norm_bases":["PB-LI-31 wydanie nr 6 z dnia 01.12.2025 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kosmetyki – pasty do zębów Zawartość fluoru\nZakres (0,03 - 0,23) %\nMetoda chromatografii gazowej z detekcją płomieniowo- jonizacyjną (GC-FID) PB-LI-31 wydanie nr 6 z dnia 01.12.2025 r. Kosmetyki – pasty do zebow Zawartosc fluoru\nZakres (0,03 - 0,23) %\nMetoda chromatografii gazowej z detekcja plomieniowo- jonizacyjna (GC-FID) PB-LI-31 wydanie nr 6 z dnia 01.12.2025 r.","categories":["pharma"],"row_index":14,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31fb","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Ryby, owoce morza i ich przetwory","methodology":"Zawartość histaminy","parameters":[{"name":"Zakres","range":"(10 - 450) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Zawartość histaminy\nZakres (10 - 450) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"PN-EN ISO 19343:2017-08","norm_bases":["PN-EN ISO 19343:2017-08"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby, owoce morza i ich przetwory Zawartość histaminy\nZakres (10 - 450) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) PN-EN ISO 19343:2017-08 Ryby, owoce morza i ich przetwory Zawartosc histaminy\nZakres (10 - 450) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) PN-EN ISO 19343:2017-08","categories":["other"],"row_index":15,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31fc","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Wyroby przeznaczone do kontaktu z żywnością wykonane z poliamidu","methodology":"Migracja pierwszorzędowych amin aromatycznych (PAAs) do płynu modelowego 3% kwasu octowego","parameters":[{"name":"Zakres","range":"2,6-toluenodiamina (2,6-TDA)"},{"name":"Zakres","range":"(0,002 - 0,64) mg/kg"},{"name":"2,4-toluenodiamina","range":"(2,4-TDA)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"1,5-diaminonaftalen","range":"(1,5-DAN)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"anilina (ANL)","range":"(0,002 - 0,64) mg/kg"},{"name":"4,4ꞌ-oksydianilina","range":"(4,4-DPE)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"4,4ꞌ-diaminodifenylometan","range":"(4,4-MDA)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"3,3ꞌ-dimetylobenzydyna","range":"(3,3-DMB)"},{"name":"(0,002 - 0,64) mg/kg"},{"name":"1,3-fenylenodiamina","range":"(0,002 - 0,64) mg/kg"},{"name":"Suma migracji PAAs (z obliczeń)"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)"],"computed":[],"activity":"Migracja pierwszorzędowych amin aromatycznych (PAAs) do płynu modelowego 3% kwasu octowego\nZakres:\nZakres 2,6-toluenodiamina (2,6-TDA)\nZakres (0,002 - 0,64) mg/kg\n2,4-toluenodiamina (2,4-TDA)\n(0,002 - 0,64) mg/kg\n1,5-diaminonaftalen (1,5-DAN)\n(0,002 - 0,64) mg/kg\nanilina (ANL) (0,002 - 0,64) mg/kg\n4,4ꞌ-oksydianilina (4,4-DPE)\n(0,002 - 0,64) mg/kg\n4,4ꞌ-diaminodifenylometan (4,4-MDA)\n(0,002 - 0,64) mg/kg\n3,3ꞌ-dimetylobenzydyna (3,3-DMB)\n(0,002 - 0,64) mg/kg\n1,3-fenylenodiamina (0,002 - 0,64) mg/kg\nSuma migracji PAAs (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD)","reference":"PB-LZ/LI-8 wydanie nr 7 z dnia 21.11.2025 r.","norm_bases":["PB-LZ/LI-8 wydanie nr 7 z dnia 21.11.2025 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby przeznaczone do kontaktu z żywnością wykonane z poliamidu Migracja pierwszorzędowych amin aromatycznych (PAAs) do płynu modelowego 3% kwasu octowego\nZakres:\nZakres 2,6-toluenodiamina (2,6-TDA)\nZakres (0,002 - 0,64) mg/kg\n2,4-toluenodiamina (2,4-TDA)\n(0,002 - 0,64) mg/kg\n1,5-diaminonaftalen (1,5-DAN)\n(0,002 - 0,64) mg/kg\nanilina (ANL) (0,002 - 0,64) mg/kg\n4,4ꞌ-oksydianilina (4,4-DPE)\n(0,002 - 0,64) mg/kg\n4,4ꞌ-diaminodifenylometan (4,4-MDA)\n(0,002 - 0,64) mg/kg\n3,3ꞌ-dimetylobenzydyna (3,3-DMB)\n(0,002 - 0,64) mg/kg\n1,3-fenylenodiamina (0,002 - 0,64) mg/kg\nSuma migracji PAAs (z obliczeń)\nMetoda wysokosprawnej chromatografii cieczowej z detekcją matrycą diodową (HPLC-DAD) PB-LZ/LI-8 wydanie nr 7 z dnia 21.11.2025 r. Wyroby przeznaczone do kontaktu z zywnoscia wykonane z poliamidu Migracja pierwszorzedowych amin aromatycznych (PAAs) do plynu modelowego 3% kwasu octowego\nZakres:\nZakres 2,6-toluenodiamina (2,6-TDA)\nZakres (0,002 - 0,64) mg/kg\n2,4-toluenodiamina (2,4-TDA)\n(0,002 - 0,64) mg/kg\n1,5-diaminonaftalen (1,5-DAN)\n(0,002 - 0,64) mg/kg\nanilina (ANL) (0,002 - 0,64) mg/kg\n4,4ꞌ-oksydianilina (4,4-DPE)\n(0,002 - 0,64) mg/kg\n4,4ꞌ-diaminodifenylometan (4,4-MDA)\n(0,002 - 0,64) mg/kg\n3,3ꞌ-dimetylobenzydyna (3,3-DMB)\n(0,002 - 0,64) mg/kg\n1,3-fenylenodiamina (0,002 - 0,64) mg/kg\nSuma migracji PAAs (z obliczen)\nMetoda wysokosprawnej chromatografii cieczowej z detekcja matryca diodowa (HPLC-DAD) PB-LZ/LI-8 wydanie nr 7 z dnia 21.11.2025 r.","categories":["food"],"row_index":16,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31fd","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Wyroby przeznaczone do kontaktu z żywnością","methodology":"Migracja bisfenolu A do płynów modelowych - 3% kwas octowy, 10% etanol, 20% etanol, 50% etanol","parameters":[{"name":"Zakres","range":"(0,002 - 0,5) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Migracja bisfenolu A do płynów modelowych - 3% kwas octowy, 10% etanol, 20% etanol, 50% etanol\nZakres (0,002 - 0,5) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-LZ/LI-12 wydanie nr 2 z dnia 21.11.2025 r.","norm_bases":["PB-LZ/LI-12 wydanie nr 2 z dnia 21.11.2025 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Wyroby przeznaczone do kontaktu z żywnością Migracja bisfenolu A do płynów modelowych - 3% kwas octowy, 10% etanol, 20% etanol, 50% etanol\nZakres (0,002 - 0,5) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-LZ/LI-12 wydanie nr 2 z dnia 21.11.2025 r. Wyroby przeznaczone do kontaktu z zywnoscia Migracja bisfenolu A do plynow modelowych - 3% kwas octowy, 10% etanol, 20% etanol, 50% etanol\nZakres (0,002 - 0,5) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-LZ/LI-12 wydanie nr 2 z dnia 21.11.2025 r.","categories":["food"],"row_index":17,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31fe","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość fosforu całkowitego i dodanego","parameters":[{"name":"Fosfor całkowity"},{"name":"Zakres","range":"(0,2 - 2,0) g/100 g (jako P2O5)"},{"name":"Fosfor dodany (z obliczeń)"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość fosforu całkowitego i dodanego\nZakres:\nFosfor całkowity\nZakres (0,2 - 2,0) g/100 g (jako P2O5)\nFosfor dodany (z obliczeń)\nMetoda spektrofotometryczna","reference":"PN-ISO 13730:1999+Ap1:2004","norm_bases":["PN-ISO 13730:1999+Ap1:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość fosforu całkowitego i dodanego\nZakres:\nFosfor całkowity\nZakres (0,2 - 2,0) g/100 g (jako P2O5)\nFosfor dodany (z obliczeń)\nMetoda spektrofotometryczna PN-ISO 13730:1999+Ap1:2004 Mieso i przetwory miesne Zawartosc fosforu calkowitego i dodanego\nZakres:\nFosfor calkowity\nZakres (0,2 - 2,0) g/100 g (jako P2O5)\nFosfor dodany (z obliczen)\nMetoda spektrofotometryczna PN-ISO 13730:1999+Ap1:2004","categories":["food"],"row_index":18,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d31ff","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci","methodology":"Zawartość tłuszczu","parameters":[{"name":"Zakres","range":"(0,02 -24,0) %"}],"technique":"Metoda ekstrakcyjno-wagowa","techniques":["Metoda ekstrakcyjno-wagowa"],"computed":[],"activity":"Zawartość tłuszczu\nZakres (0,02 -24,0) %\nMetoda ekstrakcyjno-wagowa","reference":"PB-LZ-05 wydanie nr 5 z dnia 21.11.2025 r.","norm_bases":["PB-LZ-05 wydanie nr 5 z dnia 21.11.2025 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci Zawartość tłuszczu\nZakres (0,02 -24,0) %\nMetoda ekstrakcyjno-wagowa PB-LZ-05 wydanie nr 5 z dnia 21.11.2025 r. Mieso i produkty miesne, Wyroby garmazeryjne, Koncentraty spozywcze, Produkty zbozowe, Zywnosc dla niemowlat i malych dzieci Zawartosc tluszczu\nZakres (0,02 -24,0) %\nMetoda ekstrakcyjno-wagowa PB-LZ-05 wydanie nr 5 z dnia 21.11.2025 r.","categories":["food"],"row_index":19,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3200","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci","methodology":"Zawartość wody","parameters":[{"name":"Zakres","range":"(0,8 -96,7) %"},{"name":"Zawartość suchej masy"},{"name":"Zakres","range":"(3,3 -99,2) %"}],"technique":"Metoda wagowa; Metoda wagowa","techniques":["Metoda wagowa","Metoda wagowa"],"computed":[],"activity":"Zawartość wody\nZakres:\nZakres (0,8 -96,7) %\nZawartość suchej masy\nZakres (3,3 -99,2) %\nMetoda wagowa; Metoda wagowa","reference":"PB-LZ-01 wydanie nr 2 z dnia 08.01.2026 r.","norm_bases":["PB-LZ-01 wydanie nr 2 z dnia 08.01.2026 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci Zawartość wody\nZakres:\nZakres (0,8 -96,7) %\nZawartość suchej masy\nZakres (3,3 -99,2) %\nMetoda wagowa; Metoda wagowa PB-LZ-01 wydanie nr 2 z dnia 08.01.2026 r. Mieso i produkty miesne, Wyroby garmazeryjne, Koncentraty spozywcze, Produkty zbozowe, Zywnosc dla niemowlat i malych dzieci Zawartosc wody\nZakres:\nZakres (0,8 -96,7) %\nZawartosc suchej masy\nZakres (3,3 -99,2) %\nMetoda wagowa; Metoda wagowa PB-LZ-01 wydanie nr 2 z dnia 08.01.2026 r.","categories":["food","water"],"row_index":20,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3201","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci","methodology":"Zawartość popiołu ogólnego","parameters":[{"name":"Zakres","range":"(0,1 -11,8) %"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość popiołu ogólnego\nZakres (0,1 -11,8) %\nMetoda wagowa","reference":"PB-LZ-02 wydanie nr 2 z dnia 08.01.2026 r.","norm_bases":["PB-LZ-02 wydanie nr 2 z dnia 08.01.2026 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i produkty mięsne, Wyroby garmażeryjne, Koncentraty spożywcze, Produkty zbożowe, Żywność dla niemowląt i małych dzieci Zawartość popiołu ogólnego\nZakres (0,1 -11,8) %\nMetoda wagowa PB-LZ-02 wydanie nr 2 z dnia 08.01.2026 r. Mieso i produkty miesne, Wyroby garmazeryjne, Koncentraty spozywcze, Produkty zbozowe, Zywnosc dla niemowlat i malych dzieci Zawartosc popiolu ogolnego\nZakres (0,1 -11,8) %\nMetoda wagowa PB-LZ-02 wydanie nr 2 z dnia 08.01.2026 r.","categories":["food"],"row_index":21,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3202","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością","methodology":"Migracja globalna z zastosowaniem torebki, przez całkowite zanurzenie, z zastosowaniem komory pomiarowej, przez napełnienie wyrobu do płynów modelowych:","parameters":[{"name":"Woda","range":"(2,0 - 200,0) mg/dm2"},{"name":"Zakres","range":"(12,0 - 400,0) mg/kg"},{"name":"3% kwas octowy","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"10% etanol","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"20% etanol","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"50% etanol","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"95% etanol","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"},{"name":"Izooktan","range":"(2,0 - 200,0) mg/dm2"},{"name":"(12,0 - 400,0) mg/kg"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Migracja globalna z zastosowaniem torebki, przez całkowite zanurzenie, z zastosowaniem komory pomiarowej, przez napełnienie wyrobu do płynów modelowych:\nZakres:\nWoda (2,0 - 200,0) mg/dm2\nZakres (12,0 - 400,0) mg/kg\n3% kwas octowy (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n10% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n20% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n50% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n95% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\nIzooktan (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\nMetoda wagowa","reference":"PN-EN 1186-3:2023-01","norm_bases":["PN-EN 1186-3:2023-01"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Materiały i wyroby z tworzyw sztucznych przeznaczone do kontaktu z żywnością Migracja globalna z zastosowaniem torebki, przez całkowite zanurzenie, z zastosowaniem komory pomiarowej, przez napełnienie wyrobu do płynów modelowych:\nZakres:\nWoda (2,0 - 200,0) mg/dm2\nZakres (12,0 - 400,0) mg/kg\n3% kwas octowy (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n10% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n20% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n50% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n95% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\nIzooktan (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01 Materialy i wyroby z tworzyw sztucznych przeznaczone do kontaktu z zywnoscia Migracja globalna z zastosowaniem torebki, przez calkowite zanurzenie, z zastosowaniem komory pomiarowej, przez napelnienie wyrobu do plynow modelowych:\nZakres:\nWoda (2,0 - 200,0) mg/dm2\nZakres (12,0 - 400,0) mg/kg\n3% kwas octowy (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n10% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n20% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n50% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\n95% etanol (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\nIzooktan (2,0 - 200,0) mg/dm2\n(12,0 - 400,0) mg/kg\nMetoda wagowa PN-EN 1186-3:2023-01","categories":["materials","food"],"row_index":22,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3203","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Tłoczywa melaminowo- formaldehydowe","methodology":"Migracja specyficzna formaldehydu do płynu modelowego 3% kwasu octowego","parameters":[{"name":"Zakres","range":"(3,0 – 30,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Migracja specyficzna formaldehydu do płynu modelowego 3% kwasu octowego\nZakres (3,0 – 30,0) mg/kg\nMetoda spektrofotometryczna","reference":"CN/TS 13130-23:2005","norm_bases":["CN/TS 13130-23:2005"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Tłoczywa melaminowo- formaldehydowe Migracja specyficzna formaldehydu do płynu modelowego 3% kwasu octowego\nZakres (3,0 – 30,0) mg/kg\nMetoda spektrofotometryczna CN/TS 13130-23:2005 Tloczywa melaminowo- formaldehydowe Migracja specyficzna formaldehydu do plynu modelowego 3% kwasu octowego\nZakres (3,0 – 30,0) mg/kg\nMetoda spektrofotometryczna CN/TS 13130-23:2005","categories":["other"],"row_index":23,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3204","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość witaminy C","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość witaminy C\nMetoda miareczkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość witaminy C\nMetoda miareczkowa Normy Zywnosc E Zawartosc witaminy C\nMetoda miareczkowa Normy","categories":["food"],"row_index":24,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3205","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Oleje oraz tłuszcze roślinne i zwierzęce E","methodology":"Parametry jełczenia","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Parametry jełczenia\nMetoda miareczkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Oleje oraz tłuszcze roślinne i zwierzęce E Parametry jełczenia\nMetoda miareczkowa Normy Oleje oraz tluszcze roslinne i zwierzece E Parametry jelczenia\nMetoda miareczkowa Normy","categories":["food","petro"],"row_index":25,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3206","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość dwutlenku siarki","parameters":[],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość dwutlenku siarki\nMetoda miareczkowa","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość dwutlenku siarki\nMetoda miareczkowa Normy Zywnosc E Zawartosc dwutlenku siarki\nMetoda miareczkowa Normy","categories":["food"],"row_index":26,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3207","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Zawartość pierwiastków","parameters":[{"name":"Zawartość związków (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość pierwiastków\nZawartość związków (z obliczeń)\nMetoda miareczkowa","reference":"Procedury badawcze","norm_bases":["Procedury badawcze"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Zawartość pierwiastków\nZawartość związków (z obliczeń)\nMetoda miareczkowa Procedury badawcze Zywnosc E Zawartosc pierwiastkow\nZawartosc zwiazkow (z obliczen)\nMetoda miareczkowa Procedury badawcze","categories":["food"],"row_index":27,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3208","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E, Obiekty z obszaru produkcji żywności E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Obiekty z obszaru produkcji żywności E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Zywnosc E, Obiekty z obszaru produkcji zywnosci E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["food","microbiology"],"row_index":28,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3209","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E, Kosmetyki E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Kosmetyki E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Zywnosc E, Kosmetyki E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy","categories":["food","microbiology","pharma"],"row_index":29,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d320a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E, Kosmetyki E, Obiekty z obszaru produkcji żywności E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Kosmetyki E, Obiekty z obszaru produkcji żywności E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Zywnosc E, Kosmetyki E, Obiekty z obszaru produkcji zywnosci E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["food","microbiology","pharma"],"row_index":30,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d320b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E, Obiekty z obszaru produkcji żywności E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA ŻYWNOŚCI","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E, Obiekty z obszaru produkcji żywności E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Zywnosc E, Obiekty z obszaru produkcji zywnosci E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy","categories":["food","microbiology"],"row_index":31,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d320c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(30 - 10000) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (30 - 10000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.","norm_bases":["PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie manganu\nZakres (30 - 10000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r. Woda (w tym woda na plywalni) Stezenie manganu\nZakres (30 - 10000) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.","categories":["water"],"row_index":32,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d320d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie miedzi i cynku","parameters":[{"name":"Miedź","range":"(0,04 - 25) mg/l"},{"name":"Cynk","range":"(0,20 - 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi i cynku\nZakres:\nMiedź (0,04 - 25) mg/l\nCynk (0,20 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002, metoda A","norm_bases":["PN-ISO 8288:2002, metoda A"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie miedzi i cynku\nZakres:\nMiedź (0,04 - 25) mg/l\nCynk (0,20 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002, metoda A Woda (w tym woda na plywalni) Stezenie miedzi i cynku\nZakres:\nMiedz (0,04 - 25) mg/l\nCynk (0,20 - 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002, metoda A","categories":["water"],"row_index":33,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d320e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie sodu","parameters":[{"name":"Zakres","range":"(2,50 - 500) mg/l"}],"technique":"Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","techniques":["Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)"],"computed":[],"activity":"Stężenie sodu\nZakres (2,50 - 500) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","reference":"PN-ISO 9964-3:1994","norm_bases":["PN-ISO 9964-3:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie sodu\nZakres (2,50 - 500) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES) PN-ISO 9964-3:1994 Woda (w tym woda na plywalni) Stezenie sodu\nZakres (2,50 - 500) mg/l\nMetoda plomieniowej emisyjnej spektrometrii atomowej (FAES) PN-ISO 9964-3:1994","categories":["water"],"row_index":34,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d320f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi i rtęci","parameters":[{"name":"Ołów","range":"(1,0 - 100) μg/l"},{"name":"Kadm","range":"(0,50 - 50) μg/l"},{"name":"Nikiel","range":"(1,0 - 100) μg/l"},{"name":"Chrom","range":"(5,0 - 100) μg/l"},{"name":"Glin","range":"(10,0 - 2000) μg/l"},{"name":"Mangan","range":"(5,0 - 100) μg/l"},{"name":"Antymon","range":"(0,50 - 50) μg/l"},{"name":"Arsen","range":"(1,0 - 100) μg/l"},{"name":"Selen","range":"(1,0 - 100) μg/l"},{"name":"Bor","range":"(50 - 5000) μg/l"},{"name":"Srebro","range":"(0,5 - 100) μg/l"},{"name":"Miedź","range":"(5,0 - 2100) μg/l"},{"name":"Rtęć","range":"(0,10 - 5,0) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS)"],"computed":[],"activity":"Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi i rtęci\nZakres:\nOłów (1,0 - 100) μg/l\nKadm (0,50 - 50) μg/l\nNikiel (1,0 - 100) μg/l\nChrom (5,0 - 100) μg/l\nGlin (10,0 - 2000) μg/l\nMangan (5,0 - 100) μg/l\nAntymon (0,50 - 50) μg/l\nArsen (1,0 - 100) μg/l\nSelen (1,0 - 100) μg/l\nBor (50 - 5000) μg/l\nSrebro (0,5 - 100) μg/l\nMiedź (5,0 - 2100) μg/l\nRtęć (0,10 - 5,0) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi i rtęci\nZakres:\nOłów (1,0 - 100) μg/l\nKadm (0,50 - 50) μg/l\nNikiel (1,0 - 100) μg/l\nChrom (5,0 - 100) μg/l\nGlin (10,0 - 2000) μg/l\nMangan (5,0 - 100) μg/l\nAntymon (0,50 - 50) μg/l\nArsen (1,0 - 100) μg/l\nSelen (1,0 - 100) μg/l\nBor (50 - 5000) μg/l\nSrebro (0,5 - 100) μg/l\nMiedź (5,0 - 2100) μg/l\nRtęć (0,10 - 5,0) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS) PN-EN ISO 17294-2:2024-04 Woda (w tym woda na plywalni) Stezenie olowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi i rteci\nZakres:\nOlow (1,0 - 100) μg/l\nKadm (0,50 - 50) μg/l\nNikiel (1,0 - 100) μg/l\nChrom (5,0 - 100) μg/l\nGlin (10,0 - 2000) μg/l\nMangan (5,0 - 100) μg/l\nAntymon (0,50 - 50) μg/l\nArsen (1,0 - 100) μg/l\nSelen (1,0 - 100) μg/l\nBor (50 - 5000) μg/l\nSrebro (0,5 - 100) μg/l\nMiedz (5,0 - 2100) μg/l\nRtec (0,10 - 5,0) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP MS) PN-EN ISO 17294-2:2024-04","categories":["water"],"row_index":35,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3210","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie łatwolotnych","parameters":[{"name":"chlorowcopochodnych węglowodorów"},{"name":"Trichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM):"},{"name":"Zakres","range":"(5,0 - 120) μg/l"},{"name":"Suma THM (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie łatwolotnych\nZakres:\nchlorowcopochodnych węglowodorów\nTrichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM):\nZakres (5,0 - 120) μg/l\nSuma THM (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 10301:2002 Rozdział 2","norm_bases":["PN-EN ISO 10301:2002 Rozdział 2"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie łatwolotnych\nZakres:\nchlorowcopochodnych węglowodorów\nTrichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM):\nZakres (5,0 - 120) μg/l\nSuma THM (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 10301:2002 Rozdział 2 Woda (w tym woda na plywalni) Stezenie latwolotnych\nZakres:\nchlorowcopochodnych weglowodorow\nTrichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM):\nZakres (5,0 - 120) μg/l\nSuma THM (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 10301:2002 Rozdzial 2","categories":["water"],"row_index":36,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3211","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie anionów","parameters":[{"name":"Chlorki","range":"(1,0 - 1000) mg/l"},{"name":"Azotany","range":"(1,0 - 1000) mg/l"},{"name":"Fluorki","range":"(0,10 - 10) mg/l"},{"name":"Siarczany","range":"(1,0 - 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorki (1,0 - 1000) mg/l\nAzotany (1,0 - 1000) mg/l\nFluorki (0,10 - 10) mg/l\nSiarczany (1,0 - 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie anionów\nZakres:\nChlorki (1,0 - 1000) mg/l\nAzotany (1,0 - 1000) mg/l\nFluorki (0,10 - 10) mg/l\nSiarczany (1,0 - 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Woda (w tym woda na plywalni) Stezenie anionow\nZakres:\nChlorki (1,0 - 1000) mg/l\nAzotany (1,0 - 1000) mg/l\nFluorki (0,10 - 10) mg/l\nSiarczany (1,0 - 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":37,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3212","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie manganu","parameters":[{"name":"Zakres","range":"(30 - 10000) μg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie manganu\nZakres (30 - 10000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.","norm_bases":["PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie manganu\nZakres (30 - 10000) μg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r. Woda do spozycia przez ludzi Stezenie manganu\nZakres (30 - 10000) μg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PB-LFI-01 wydanie nr 2 z dnia 17.01.2014 r.","categories":["water"],"row_index":38,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3213","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie miedzi i cynku","parameters":[{"name":"Miedź","range":"(0,04 - 25) mg/l"},{"name":"Cynk","range":"(0,20 - 10) mg/l"}],"technique":"Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","techniques":["Metoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)"],"computed":[],"activity":"Stężenie miedzi i cynku\nZakres:\nMiedź (0,04 - 25) mg/l\nCynk (0,20 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS)","reference":"PN-ISO 8288:2002, metoda A","norm_bases":["PN-ISO 8288:2002, metoda A"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie miedzi i cynku\nZakres:\nMiedź (0,04 - 25) mg/l\nCynk (0,20 - 10) mg/l\nMetoda płomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002, metoda A Woda do spozycia przez ludzi Stezenie miedzi i cynku\nZakres:\nMiedz (0,04 - 25) mg/l\nCynk (0,20 - 10) mg/l\nMetoda plomieniowej absorpcyjnej spektrometrii atomowej (FAAS) PN-ISO 8288:2002, metoda A","categories":["water"],"row_index":39,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3214","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie sodu","parameters":[{"name":"Zakres","range":"(2,50 - 500) mg/l"}],"technique":"Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","techniques":["Metoda płomieniowej emisyjnej spektrometrii atomowej (FAES)"],"computed":[],"activity":"Stężenie sodu\nZakres (2,50 - 500) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES)","reference":"PN-ISO 9964-3:1994","norm_bases":["PN-ISO 9964-3:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie sodu\nZakres (2,50 - 500) mg/l\nMetoda płomieniowej emisyjnej spektrometrii atomowej (FAES) PN-ISO 9964-3:1994 Woda do spozycia przez ludzi Stezenie sodu\nZakres (2,50 - 500) mg/l\nMetoda plomieniowej emisyjnej spektrometrii atomowej (FAES) PN-ISO 9964-3:1994","categories":["water"],"row_index":40,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3215","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie anionów","parameters":[{"name":"Chlorki","range":"(1,0 - 1000) mg/l"},{"name":"Azotyny","range":"(0,030 - 10) mg/l"},{"name":"Azotany","range":"(1,0 - 1000) mg/l"},{"name":"Fluorki","range":"(0,10 - 10) mg/l"},{"name":"Siarczany","range":"(1,0 - 1000) mg/l"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie anionów\nZakres:\nChlorki (1,0 - 1000) mg/l\nAzotyny (0,030 - 10) mg/l\nAzotany (1,0 - 1000) mg/l\nFluorki (0,10 - 10) mg/l\nSiarczany (1,0 - 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-1:2009 +AC:2012","norm_bases":["PN-EN ISO 10304-1:2009 +AC:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie anionów\nZakres:\nChlorki (1,0 - 1000) mg/l\nAzotyny (0,030 - 10) mg/l\nAzotany (1,0 - 1000) mg/l\nFluorki (0,10 - 10) mg/l\nSiarczany (1,0 - 1000) mg/l\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012 Woda do spozycia przez ludzi Stezenie anionow\nZakres:\nChlorki (1,0 - 1000) mg/l\nAzotyny (0,030 - 10) mg/l\nAzotany (1,0 - 1000) mg/l\nFluorki (0,10 - 10) mg/l\nSiarczany (1,0 - 1000) mg/l\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-1:2009 +AC:2012","categories":["water"],"row_index":41,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3216","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi, rtęci i uranu","parameters":[{"name":"Ołów","range":"(1,0 - 100) μg/l"},{"name":"Kadm","range":"(0,50 - 50) μg/l"},{"name":"Nikiel","range":"(1,0 - 100) μg/l"},{"name":"Chrom","range":"(5,0 - 100) μg/l"},{"name":"Glin","range":"(10,0 - 2000) μg/l"},{"name":"Mangan","range":"(5,0 - 100) μg/l"},{"name":"Antymon","range":"(0,50 - 50) μg/l"},{"name":"Arsen","range":"(1,0 - 100) μg/l"},{"name":"Selen","range":"(1,0 - 100) μg/l"},{"name":"Bor","range":"(50 - 5000) μg/l"},{"name":"Srebro","range":"(0,5 - 100) μg/l"},{"name":"Miedź","range":"(5,0 - 2100) μg/l"},{"name":"Rtęć","range":"(0,10 - 5,0) μg/l"},{"name":"Uran","range":"(1,0 - 100) μg/l"}],"technique":"Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS)","techniques":["Metoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS)"],"computed":[],"activity":"Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi, rtęci i uranu\nZakres:\nOłów (1,0 - 100) μg/l\nKadm (0,50 - 50) μg/l\nNikiel (1,0 - 100) μg/l\nChrom (5,0 - 100) μg/l\nGlin (10,0 - 2000) μg/l\nMangan (5,0 - 100) μg/l\nAntymon (0,50 - 50) μg/l\nArsen (1,0 - 100) μg/l\nSelen (1,0 - 100) μg/l\nBor (50 - 5000) μg/l\nSrebro (0,5 - 100) μg/l\nMiedź (5,0 - 2100) μg/l\nRtęć (0,10 - 5,0) μg/l\nUran (1,0 - 100) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS)","reference":"PN-EN ISO 17294-2:2024-04","norm_bases":["PN-EN ISO 17294-2:2024-04"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie ołowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi, rtęci i uranu\nZakres:\nOłów (1,0 - 100) μg/l\nKadm (0,50 - 50) μg/l\nNikiel (1,0 - 100) μg/l\nChrom (5,0 - 100) μg/l\nGlin (10,0 - 2000) μg/l\nMangan (5,0 - 100) μg/l\nAntymon (0,50 - 50) μg/l\nArsen (1,0 - 100) μg/l\nSelen (1,0 - 100) μg/l\nBor (50 - 5000) μg/l\nSrebro (0,5 - 100) μg/l\nMiedź (5,0 - 2100) μg/l\nRtęć (0,10 - 5,0) μg/l\nUran (1,0 - 100) μg/l\nMetoda spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP MS) PN-EN ISO 17294-2:2024-04 Woda do spozycia przez ludzi Stezenie olowiu, kadmu, niklu, chromu, glinu, manganu, antymonu, arsenu, selenu, boru, srebra, miedzi, rteci i uranu\nZakres:\nOlow (1,0 - 100) μg/l\nKadm (0,50 - 50) μg/l\nNikiel (1,0 - 100) μg/l\nChrom (5,0 - 100) μg/l\nGlin (10,0 - 2000) μg/l\nMangan (5,0 - 100) μg/l\nAntymon (0,50 - 50) μg/l\nArsen (1,0 - 100) μg/l\nSelen (1,0 - 100) μg/l\nBor (50 - 5000) μg/l\nSrebro (0,5 - 100) μg/l\nMiedz (5,0 - 2100) μg/l\nRtec (0,10 - 5,0) μg/l\nUran (1,0 - 100) μg/l\nMetoda spektrometrii mas z jonizacja w plazmie indukcyjnie sprzezonej (ICP MS) PN-EN ISO 17294-2:2024-04","categories":["water"],"row_index":42,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3217","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie łatwolotnych chlorowcopochodnych węglowodorów:","parameters":[{"name":"Trichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM)"},{"name":"Zakres","range":"(5,0 -120) μg/l"},{"name":"Tetrachloroeten, trichloroeten","range":"(1,0 - 20,5) μg/l"},{"name":"Tetrachlorometan","range":"(0,20 - 4,10) μg/l"},{"name":"1,2-dichloroetan","range":"(0,80 - 6,4) μg/l"},{"name":"Suma THM (z obliczeń) Suma tetrachloroetenu i trichloroetenu ( z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD, HS-GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD, HS-GC-ECD)"],"computed":[],"activity":"Stężenie łatwolotnych chlorowcopochodnych węglowodorów:\nZakres:\nTrichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM)\nZakres (5,0 -120) μg/l\nTetrachloroeten, trichloroeten (1,0 - 20,5) μg/l\nTetrachlorometan (0,20 - 4,10) μg/l\n1,2-dichloroetan (0,80 - 6,4) μg/l\nSuma THM (z obliczeń) Suma tetrachloroetenu i trichloroetenu ( z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD, HS-GC-ECD)","reference":"PN-EN ISO 10301:2002 Rozdział 2 i 3","norm_bases":["PN-EN ISO 10301:2002 Rozdział 2 i 3"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie łatwolotnych chlorowcopochodnych węglowodorów:\nZakres:\nTrichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM)\nZakres (5,0 -120) μg/l\nTetrachloroeten, trichloroeten (1,0 - 20,5) μg/l\nTetrachlorometan (0,20 - 4,10) μg/l\n1,2-dichloroetan (0,80 - 6,4) μg/l\nSuma THM (z obliczeń) Suma tetrachloroetenu i trichloroetenu ( z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD, HS-GC-ECD) PN-EN ISO 10301:2002 Rozdział 2 i 3 Woda do spozycia przez ludzi Stezenie latwolotnych chlorowcopochodnych weglowodorow:\nZakres:\nTrichlorometan, tribromometan, dichlorobromometan, dibromochlorometan (THM)\nZakres (5,0 -120) μg/l\nTetrachloroeten, trichloroeten (1,0 - 20,5) μg/l\nTetrachlorometan (0,20 - 4,10) μg/l\n1,2-dichloroetan (0,80 - 6,4) μg/l\nSuma THM (z obliczen) Suma tetrachloroetenu i trichloroetenu ( z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD, HS-GC-ECD) PN-EN ISO 10301:2002 Rozdzial 2 i 3","categories":["water"],"row_index":43,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3218","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie pestycydów","parameters":[{"name":"Aldryna","range":"(0,005 - 0,060) μg/l"},{"name":"Dieldryna","range":"(0,005 - 0,060) μg/l"},{"name":"Heptachlor","range":"(0,005 - 0,060) μg/l"},{"name":"Heptachlor endo-epoxyd A"},{"name":"Zakres","range":"(0,005 - 0,060) μg/l"},{"name":"Heptachlor exo-epoxyd B","range":"(0,005 - 0,060) μg/l"},{"name":"Chlordan-cis","range":"(0,010 - 0,120) μg/l"},{"name":"Chlordan-trans","range":"(0,010 - 0,120) μg/l"},{"name":"DDD","range":"(0,010 - 0,120) μg/l"},{"name":"DDE","range":"(0,010 - 0,120) μg/l"},{"name":"DDT","range":"(0,010 - 0,120) μg/l"},{"name":"Endosulfan α","range":"(0,010 - 0,120) μg/l"},{"name":"Endosulfan β","range":"(0,010 - 0,120) μg/l"},{"name":"Trifluralin","range":"(0,010 - 0,120) μg/l"},{"name":"PeCB","range":"(0,010- 0,120) μg/l"},{"name":"HCB","range":"(0,010 - 0,120) μg/l"},{"name":"HCH α","range":"(0,010 - 0,120) μg/l"},{"name":"HCH β","range":"(0,010 - 0,120) μg/l"},{"name":"HCH γ","range":"(0,010 - 0,120) μg/l"},{"name":"HCH δ","range":"(0,010 - 0,120) μg/l"},{"name":"Permetryna","range":"(0,010 - 0,120) μg/l"},{"name":"Cypermetryna","range":"(0,010 - 0,120) μg/l"},{"name":"Fenwalerat","range":"(0,010 - 0,120) μg/l"},{"name":"Deltametryna","range":"(0,010 - 0,120) μg/l"},{"name":"Suma pestycydów (z obliczeń)"}],"technique":"Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","techniques":["Metoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)"],"computed":[],"activity":"Stężenie pestycydów\nZakres:\nAldryna (0,005 - 0,060) μg/l\nDieldryna (0,005 - 0,060) μg/l\nHeptachlor (0,005 - 0,060) μg/l\nHeptachlor endo-epoxyd A\nZakres (0,005 - 0,060) μg/l\nHeptachlor exo-epoxyd B (0,005 - 0,060) μg/l\nChlordan-cis (0,010 - 0,120) μg/l\nChlordan-trans (0,010 - 0,120) μg/l\nDDD (0,010 - 0,120) μg/l\nDDE (0,010 - 0,120) μg/l\nDDT (0,010 - 0,120) μg/l\nEndosulfan α (0,010 - 0,120) μg/l\nEndosulfan β (0,010 - 0,120) μg/l\nTrifluralin (0,010 - 0,120) μg/l\nPeCB (0,010- 0,120) μg/l\nHCB (0,010 - 0,120) μg/l\nHCH α (0,010 - 0,120) μg/l\nHCH β (0,010 - 0,120) μg/l\nHCH γ (0,010 - 0,120) μg/l\nHCH δ (0,010 - 0,120) μg/l\nPermetryna (0,010 - 0,120) μg/l\nCypermetryna (0,010 - 0,120) μg/l\nFenwalerat (0,010 - 0,120) μg/l\nDeltametryna (0,010 - 0,120) μg/l\nSuma pestycydów (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD)","reference":"PN-EN ISO 6468:2002","norm_bases":["PN-EN ISO 6468:2002"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie pestycydów\nZakres:\nAldryna (0,005 - 0,060) μg/l\nDieldryna (0,005 - 0,060) μg/l\nHeptachlor (0,005 - 0,060) μg/l\nHeptachlor endo-epoxyd A\nZakres (0,005 - 0,060) μg/l\nHeptachlor exo-epoxyd B (0,005 - 0,060) μg/l\nChlordan-cis (0,010 - 0,120) μg/l\nChlordan-trans (0,010 - 0,120) μg/l\nDDD (0,010 - 0,120) μg/l\nDDE (0,010 - 0,120) μg/l\nDDT (0,010 - 0,120) μg/l\nEndosulfan α (0,010 - 0,120) μg/l\nEndosulfan β (0,010 - 0,120) μg/l\nTrifluralin (0,010 - 0,120) μg/l\nPeCB (0,010- 0,120) μg/l\nHCB (0,010 - 0,120) μg/l\nHCH α (0,010 - 0,120) μg/l\nHCH β (0,010 - 0,120) μg/l\nHCH γ (0,010 - 0,120) μg/l\nHCH δ (0,010 - 0,120) μg/l\nPermetryna (0,010 - 0,120) μg/l\nCypermetryna (0,010 - 0,120) μg/l\nFenwalerat (0,010 - 0,120) μg/l\nDeltametryna (0,010 - 0,120) μg/l\nSuma pestycydów (z obliczeń)\nMetoda chromatografii gazowej z detekcją wychwytu elektronów (GC-ECD) PN-EN ISO 6468:2002 Woda do spozycia przez ludzi Stezenie pestycydow\nZakres:\nAldryna (0,005 - 0,060) μg/l\nDieldryna (0,005 - 0,060) μg/l\nHeptachlor (0,005 - 0,060) μg/l\nHeptachlor endo-epoxyd A\nZakres (0,005 - 0,060) μg/l\nHeptachlor exo-epoxyd B (0,005 - 0,060) μg/l\nChlordan-cis (0,010 - 0,120) μg/l\nChlordan-trans (0,010 - 0,120) μg/l\nDDD (0,010 - 0,120) μg/l\nDDE (0,010 - 0,120) μg/l\nDDT (0,010 - 0,120) μg/l\nEndosulfan α (0,010 - 0,120) μg/l\nEndosulfan β (0,010 - 0,120) μg/l\nTrifluralin (0,010 - 0,120) μg/l\nPeCB (0,010- 0,120) μg/l\nHCB (0,010 - 0,120) μg/l\nHCH α (0,010 - 0,120) μg/l\nHCH β (0,010 - 0,120) μg/l\nHCH γ (0,010 - 0,120) μg/l\nHCH δ (0,010 - 0,120) μg/l\nPermetryna (0,010 - 0,120) μg/l\nCypermetryna (0,010 - 0,120) μg/l\nFenwalerat (0,010 - 0,120) μg/l\nDeltametryna (0,010 - 0,120) μg/l\nSuma pestycydow (z obliczen)\nMetoda chromatografii gazowej z detekcja wychwytu elektronow (GC-ECD) PN-EN ISO 6468:2002","categories":["water"],"row_index":44,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3219","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chlorynów","parameters":[{"name":"Zakres","range":"(0,050 - 10) mg/l"},{"name":"Stężenie chloranów"},{"name":"Zakres","range":"(0,050 - 10) mg/l"},{"name":"Suma chlorynów i chloranów (z obliczeń)"}],"technique":"Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","techniques":["Metoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)"],"computed":[],"activity":"Stężenie chlorynów\nZakres:\nZakres (0,050 - 10) mg/l\nStężenie chloranów\nZakres (0,050 - 10) mg/l\nSuma chlorynów i chloranów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD)","reference":"PN-EN ISO 10304-4:2022-08","norm_bases":["PN-EN ISO 10304-4:2022-08"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chlorynów\nZakres:\nZakres (0,050 - 10) mg/l\nStężenie chloranów\nZakres (0,050 - 10) mg/l\nSuma chlorynów i chloranów (z obliczeń)\nMetoda chromatografii jonowej z detekcją konduktometryczną (IC-CD) PN-EN ISO 10304-4:2022-08 Woda do spozycia przez ludzi Stezenie chlorynow\nZakres:\nZakres (0,050 - 10) mg/l\nStezenie chloranow\nZakres (0,050 - 10) mg/l\nSuma chlorynow i chloranow (z obliczen)\nMetoda chromatografii jonowej z detekcja konduktometryczna (IC-CD) PN-EN ISO 10304-4:2022-08","categories":["water"],"row_index":45,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d321a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie bromianów","parameters":[{"name":"Zakres","range":"(2,0 - 50) μg/l"}],"technique":"Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/VIS)","techniques":["Metoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/VIS)"],"computed":[],"activity":"Stężenie bromianów\nZakres (2,0 - 50) μg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/VIS)","reference":"PN-EN ISO 11206:2013-07","norm_bases":["PN-EN ISO 11206:2013-07"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie bromianów\nZakres (2,0 - 50) μg/l\nMetoda chromatografii jonowej z detekcją spektrofotometryczną (IC-UV/VIS) PN-EN ISO 11206:2013-07 Woda do spozycia przez ludzi Stezenie bromianow\nZakres (2,0 - 50) μg/l\nMetoda chromatografii jonowej z detekcja spektrofotometryczna (IC-UV/VIS) PN-EN ISO 11206:2013-07","categories":["water"],"row_index":46,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d321b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)","parameters":[{"name":"Benzo(b)fluoranten"},{"name":"Zakres","range":"(0,0020 - 0,030) μg/l"},{"name":"Benzo(k)fluoranten","range":"(0,0020 - 0,030) μg/l"},{"name":"Benzo(ghi)perylen","range":"(0,0020 - 0,030) μg/l"},{"name":"Indeno","range":"(1,2,3-cd)piren"},{"name":"(0,0020 - 0,030) μg/l"},{"name":"Suma WWA (z obliczeń) Benzo(a)piren"},{"name":"Zakres","range":"(0,0020 - 0,030) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD); Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nBenzo(b)fluoranten\nZakres (0,0020 - 0,030) μg/l\nBenzo(k)fluoranten (0,0020 - 0,030) μg/l\nBenzo(ghi)perylen (0,0020 - 0,030) μg/l\nIndeno (1,2,3-cd)piren\n(0,0020 - 0,030) μg/l\nSuma WWA (z obliczeń) Benzo(a)piren\nZakres (0,0020 - 0,030) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD); Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-LI-16 wydanie nr 5 z dnia 02.12.2025 r.","norm_bases":["PB-LI-16 wydanie nr 5 z dnia 02.12.2025 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie wielopierścieniowych węglowodorów aromatycznych (WWA)\nZakres:\nBenzo(b)fluoranten\nZakres (0,0020 - 0,030) μg/l\nBenzo(k)fluoranten (0,0020 - 0,030) μg/l\nBenzo(ghi)perylen (0,0020 - 0,030) μg/l\nIndeno (1,2,3-cd)piren\n(0,0020 - 0,030) μg/l\nSuma WWA (z obliczeń) Benzo(a)piren\nZakres (0,0020 - 0,030) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD); Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-LI-16 wydanie nr 5 z dnia 02.12.2025 r. Woda do spozycia przez ludzi Stezenie wielopierscieniowych weglowodorow aromatycznych (WWA)\nZakres:\nBenzo(b)fluoranten\nZakres (0,0020 - 0,030) μg/l\nBenzo(k)fluoranten (0,0020 - 0,030) μg/l\nBenzo(ghi)perylen (0,0020 - 0,030) μg/l\nIndeno (1,2,3-cd)piren\n(0,0020 - 0,030) μg/l\nSuma WWA (z obliczen) Benzo(a)piren\nZakres (0,0020 - 0,030) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD); Metoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-LI-16 wydanie nr 5 z dnia 02.12.2025 r.","categories":["water"],"row_index":47,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d321c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie bisfenolu A","parameters":[{"name":"Zakres","range":"(0,50 – 7,5) μg/l"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)"],"computed":[],"activity":"Stężenie bisfenolu A\nZakres (0,50 – 7,5) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD)","reference":"PB-LI-37 wydanie nr 2 z dnia 19.12.2025 r.","norm_bases":["PB-LI-37 wydanie nr 2 z dnia 19.12.2025 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY, ODDZIAŁ LABORATORYJNY BADAŃ I POMIARÓW INSTRUMENTALNYCH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie bisfenolu A\nZakres (0,50 – 7,5) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcją fluorescencyjną (HPLC-FLD) PB-LI-37 wydanie nr 2 z dnia 19.12.2025 r. Woda do spozycia przez ludzi Stezenie bisfenolu A\nZakres (0,50 – 7,5) μg/l\nMetoda wysokosprawnej chromatografii cieczowej z detekcja fluorescencyjna (HPLC-FLD) PB-LI-37 wydanie nr 2 z dnia 19.12.2025 r.","categories":["water"],"row_index":48,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d321d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(20,0 - 1000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (20,0 - 1000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie żelaza\nZakres (20,0 - 1000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda (w tym woda na plywalni) Stezenie zelaza\nZakres (20,0 - 1000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":49,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d321e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalni) pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":50,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d321f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(84 - 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (84 - 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Przewodność elektryczna właściwa\nZakres (84 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda (w tym woda na plywalni) Przewodnosc elektryczna wlasciwa\nZakres (84 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":51,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3220","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,060 - 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,060 - 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie azotu amonowego\nZakres (0,060 - 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda (w tym woda na plywalni) Stezenie azotu amonowego\nZakres (0,060 - 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":52,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3221","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 - 10) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 - 10) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Mętność\nZakres (0,20 - 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym woda na plywalni) Metnosc\nZakres (0,20 - 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":53,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3222","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(1,0 - 25) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (1,0 - 25) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie ogólnego węgla organicznego\nZakres (1,0 - 25) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda (w tym woda na plywalni) Stezenie ogolnego wegla organicznego\nZakres (1,0 - 25) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":54,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3223","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Indeks nadmanganianowy (utlenialność)","parameters":[{"name":"Zakres","range":"(0,55 - 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy (utlenialność)\nZakres (0,55 - 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Indeks nadmanganianowy (utlenialność)\nZakres (0,55 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalni) Indeks nadmanganianowy (utlenialnosc)\nZakres (0,55 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":55,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3224","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 - 5000) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 - 5000) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie chlorków\nZakres (5,0 - 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda (w tym woda na plywalni) Stezenie chlorkow\nZakres (5,0 - 5000) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":56,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3225","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza","parameters":[{"name":"Zakres","range":"(20,0 - 1000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza\nZakres (20,0 - 1000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza\nZakres (20,0 - 1000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza\nZakres (20,0 - 1000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":57,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3226","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":58,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3227","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(84- 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (84- 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (84- 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (84- 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":59,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3228","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotu amonowego","parameters":[{"name":"Zakres","range":"(0,060 - 1,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotu amonowego\nZakres (0,060 - 1,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotu amonowego\nZakres (0,060 - 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie azotu amonowego\nZakres (0,060 - 1,0) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":60,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3229","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,20 - 10) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,20 - 10) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,20 - 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,20 - 10) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":61,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d322a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie ogólnego węgla organicznego","parameters":[{"name":"Zakres","range":"(1,0 - 25) mg/l"}],"technique":"Metoda wysokotemperaturowego spalania z detekcją IR","techniques":["Metoda wysokotemperaturowego spalania z detekcją IR"],"computed":[],"activity":"Stężenie ogólnego węgla organicznego\nZakres (1,0 - 25) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR","reference":"PN-EN 1484:1999","norm_bases":["PN-EN 1484:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie ogólnego węgla organicznego\nZakres (1,0 - 25) mg/l\nMetoda wysokotemperaturowego spalania z detekcją IR PN-EN 1484:1999 Woda do spozycia przez ludzi Stezenie ogolnego wegla organicznego\nZakres (1,0 - 25) mg/l\nMetoda wysokotemperaturowego spalania z detekcja IR PN-EN 1484:1999","categories":["water"],"row_index":62,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d322b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy (utlenialność)","parameters":[{"name":"Zakres","range":"(0,55 - 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy (utlenialność)\nZakres (0,55 - 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Indeks nadmanganianowy (utlenialność)\nZakres (0,55 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Indeks nadmanganianowy (utlenialnosc)\nZakres (0,55 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":63,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d322c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(5 - 1000) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 - 1000) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (5 - 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (5 - 1000) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":64,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d322d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie wapnia","parameters":[{"name":"Zakres","range":"(2 - 100) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie wapnia\nZakres (2 - 100) mg/l\nMetoda miareczkowa","reference":"PN-ISO 6058:1999","norm_bases":["PN-ISO 6058:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie wapnia\nZakres (2 - 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999 Woda do spozycia przez ludzi Stezenie wapnia\nZakres (2 - 100) mg/l\nMetoda miareczkowa PN-ISO 6058:1999","categories":["water"],"row_index":65,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d322e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie magnezu (z obliczeń)","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Stężenie magnezu (z obliczeń)","reference":"PN-C-04554-4:1999 Załącznik A","norm_bases":["PN-C-04554-4:1999 Załącznik A"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie magnezu (z obliczeń) PN-C-04554-4:1999 Załącznik A Woda do spozycia przez ludzi Stezenie magnezu (z obliczen) PN-C-04554-4:1999 Zalacznik A","categories":["water"],"row_index":66,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d322f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,0 - 300) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,0 - 300) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,0 - 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,0 - 300) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":67,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3230","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym woda na plywalni) Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":68,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3231","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda (w tym woda na plywalni) Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":69,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3232","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda (w tym woda na plywalni) Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":70,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3233","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda (w tym woda na plywalni) Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":71,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3234","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda (w tym woda na plywalni) Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":72,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3235","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Ogólna liczba mikroorganizmów w temperaturze 36oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda (w tym woda na plywalni) Ogolna liczba mikroorganizmow w temperaturze 36oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":73,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3236","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Liczba gronkowców koagulazododatnich","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej","reference":"Metodyka PZH ZHK z dnia 23.04.2007 r.","norm_bases":["Metodyka PZH ZHK z dnia 23.04.2007 r."],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Liczba gronkowców koagulazododatnich\nMetoda filtracji membranowej Metodyka PZH ZHK z dnia 23.04.2007 r. Woda (w tym woda na plywalni) Liczba gronkowcow koagulazododatnich\nMetoda filtracji membranowej Metodyka PZH ZHK z dnia 23.04.2007 r.","categories":["water"],"row_index":74,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3237","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda (w tym woda na plywalni) Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":75,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3238","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii grupy coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii grupy coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba bakterii grupy coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":76,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3239","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Escherichia coli","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Escherichia coli\nMetoda filtracji membranowej","reference":"PN-EN ISO 9308-1:2014-12 +A1:2017-04","norm_bases":["PN-EN ISO 9308-1:2014-12 +A1:2017-04"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04 Woda do spozycia przez ludzi Liczba Escherichia coli\nMetoda filtracji membranowej PN-EN ISO 9308-1:2014-12 +A1:2017-04","categories":["water","microbiology"],"row_index":77,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d323a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba bakterii grupy coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba bakterii grupy coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":78,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d323b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Najbardziej prawdopodobna liczba, Escherichia coli","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL","reference":"PN-EN ISO 9308-2:2014-06","norm_bases":["PN-EN ISO 9308-2:2014-06"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06 Woda do spozycia przez ludzi Najbardziej prawdopodobna liczba, Escherichia coli\nMetoda NPL PN-EN ISO 9308-2:2014-06","categories":["water","microbiology"],"row_index":79,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d323c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 22oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 22oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 22oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 22oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":80,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d323d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Ogólna liczba mikroorganizmów w temperaturze 36oC","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Ogólna liczba mikroorganizmów w temperaturze 36oC\nMetoda płytkowa (posiew wgłębny)","reference":"PN-EN ISO 6222:2004","norm_bases":["PN-EN ISO 6222:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Ogólna liczba mikroorganizmów w temperaturze 36oC\nMetoda płytkowa (posiew wgłębny) PN-EN ISO 6222:2004 Woda do spozycia przez ludzi Ogolna liczba mikroorganizmow w temperaturze 36oC\nMetoda plytkowa (posiew wglebny) PN-EN ISO 6222:2004","categories":["water"],"row_index":81,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d323e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba Pseudomonas aeruginosa","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej","reference":"PN-EN ISO 16266:2009","norm_bases":["PN-EN ISO 16266:2009"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009 Woda do spozycia przez ludzi Liczba Pseudomonas aeruginosa\nMetoda filtracji membranowej PN-EN ISO 16266:2009","categories":["water"],"row_index":82,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d323f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba enterokoków kałowych","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba enterokoków kałowych\nMetoda filtracji membranowej","reference":"PN-EN ISO 7899-2:2004","norm_bases":["PN-EN ISO 7899-2:2004"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba enterokoków kałowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004 Woda do spozycia przez ludzi Liczba enterokokow kalowych\nMetoda filtracji membranowej PN-EN ISO 7899-2:2004","categories":["water"],"row_index":83,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3240","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii Clostridium perfringens (łącznie ze sporami)","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej","reference":"PN-EN ISO 14189:2016-10","norm_bases":["PN-EN ISO 14189:2016-10"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii Clostridium perfringens (łącznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10 Woda do spozycia przez ludzi Liczba bakterii Clostridium perfringens (lacznie ze sporami)\nMetoda filtracji membranowej PN-EN ISO 14189:2016-10","categories":["water","microbiology"],"row_index":84,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3241","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba bakterii z rodzaju Legionella","parameters":[{"name":"Matryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC) Posiew bezpośredni Matryca A Procedura 1 (pożywka BCYE i BCYE+AB)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC) Posiew bezpośredni Matryca A Procedura 1 (pożywka BCYE i BCYE+AB)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019:12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019:12"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pożywka BCYE) Procedura 7 (pożywka GVPC) Posiew bezpośredni Matryca A Procedura 1 (pożywka BCYE i BCYE+AB)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019:12 Woda do spozycia przez ludzi Liczba bakterii z rodzaju Legionella\nMatryca A Procedura 5 (pozywka BCYE) Procedura 7 (pozywka GVPC) Posiew bezposredni Matryca A Procedura 1 (pozywka BCYE i BCYE+AB)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019:12","categories":["microbiology","water"],"row_index":85,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3242","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda na pływalniach","methodology":"Liczba bakterii z rodzaju Legionella","parameters":[{"name":"Matryca B Procedura 7 (pożywka GVPC)"}],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba bakterii z rodzaju Legionella\nMatryca B Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej","reference":"PN-EN ISO 11731:2017-08 +Ap1:2019:12","norm_bases":["PN-EN ISO 11731:2017-08 +Ap1:2019:12"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda na pływalniach Liczba bakterii z rodzaju Legionella\nMatryca B Procedura 7 (pożywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019:12 Woda na plywalniach Liczba bakterii z rodzaju Legionella\nMatryca B Procedura 7 (pozywka GVPC)\nMetoda filtracji membranowej PN-EN ISO 11731:2017-08 +Ap1:2019:12","categories":["microbiology","water"],"row_index":86,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3243","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Identyfikacja grup serologicznych bakterii z rodzaju Legionella","parameters":[],"technique":"Metoda serologiczna, test aglutynacji lateksowej","techniques":["Metoda serologiczna, test aglutynacji lateksowej"],"computed":[],"activity":"Identyfikacja grup serologicznych bakterii z rodzaju Legionella\nMetoda serologiczna, test aglutynacji lateksowej","reference":"Instrukcja producenta Oxoid Legionella Latex Test Wydanie X5057H, luty 2026","norm_bases":["Instrukcja producenta Oxoid Legionella Latex Test Wydanie X5057H, luty 2026"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Identyfikacja grup serologicznych bakterii z rodzaju Legionella\nMetoda serologiczna, test aglutynacji lateksowej Instrukcja producenta Oxoid Legionella Latex Test Wydanie X5057H, luty 2026 Woda do spozycia przez ludzi, Woda na plywalniach Identyfikacja grup serologicznych bakterii z rodzaju Legionella\nMetoda serologiczna, test aglutynacji lateksowej Instrukcja producenta Oxoid Legionella Latex Test Wydanie X5057H, luty 2026","categories":["microbiology","water"],"row_index":87,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3244","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi, Woda na pływalniach","methodology":"Identyfikacja grup serologicznych bakterii z rodzaju Legionella","parameters":[],"technique":"Metoda serologiczna, test aglutynacji lateksowej","techniques":["Metoda serologiczna, test aglutynacji lateksowej"],"computed":[],"activity":"Identyfikacja grup serologicznych bakterii z rodzaju Legionella\nMetoda serologiczna, test aglutynacji lateksowej","reference":"Instrukcja producenta BIOMAXIMA Legionella Latex Rapid Test Aktualizacja 13.10.2025","norm_bases":["Instrukcja producenta BIOMAXIMA Legionella Latex Rapid Test Aktualizacja 13.10.2025"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi, Woda na pływalniach Identyfikacja grup serologicznych bakterii z rodzaju Legionella\nMetoda serologiczna, test aglutynacji lateksowej Instrukcja producenta BIOMAXIMA Legionella Latex Rapid Test Aktualizacja 13.10.2025 Woda do spozycia przez ludzi, Woda na plywalniach Identyfikacja grup serologicznych bakterii z rodzaju Legionella\nMetoda serologiczna, test aglutynacji lateksowej Instrukcja producenta BIOMAXIMA Legionella Latex Rapid Test Aktualizacja 13.10.2025","categories":["microbiology","water"],"row_index":88,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3245","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Liczba colifagów somatycznych","parameters":[],"technique":"Metoda płytek dwuwarstwowych (DAL)","techniques":["Metoda płytek dwuwarstwowych (DAL)"],"computed":[],"activity":"Liczba colifagów somatycznych\nMetoda płytek dwuwarstwowych (DAL)","reference":"PN-EN ISO 10705-2:2005","norm_bases":["PN-EN ISO 10705-2:2005"],"lab_section":"ODDZIAŁ LABORATORYJNY BADANIA WODY","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Liczba colifagów somatycznych\nMetoda płytek dwuwarstwowych (DAL) PN-EN ISO 10705-2:2005 Woda do spozycia przez ludzi Liczba colifagow somatycznych\nMetoda plytek dwuwarstwowych (DAL) PN-EN ISO 10705-2:2005","categories":["water"],"row_index":89,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3246","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii","methodology":"Indukcja magnetyczna w zakresie częstotliwości (20 - 50) Hz","parameters":[{"name":"zakres","range":"0,5 μT - 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia (uproszczona)","techniques":["Metoda pomiarowa bezpośrednia (uproszczona)"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości (20 - 50) Hz\nzakres 0,5 μT - 19 mT\nMetoda pomiarowa bezpośrednia (uproszczona)","reference":"Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180","norm_bases":["Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180"],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzące od urządzeń do magnetoterapii Indukcja magnetyczna w zakresie częstotliwości (20 - 50) Hz\nzakres 0,5 μT - 19 mT\nMetoda pomiarowa bezpośrednia (uproszczona) Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 Srodowisko pracy - pole elektromagnetyczne w przestrzeni pracy pochodzace od urzadzen do magnetoterapii Indukcja magnetyczna w zakresie czestotliwosci (20 - 50) Hz\nzakres 0,5 μT - 19 mT\nMetoda pomiarowa bezposrednia (uproszczona) Podstawy i Metody Oceny Srodowiska Pracy 2016, nr 4 (90), s. 151 - 180","categories":["environment"],"row_index":90,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3247","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Środowisko pracy - pola elektromagnetyczne","methodology":"Natężenie pola elektrycznego w paśmie częstotliwości:","parameters":[{"name":"10 Hz - 400 kHz"},{"name":"zakres","range":"1 V/m - 50 kV/m"},{"name":"400 kHz - 3 MHz"},{"name":"zakres","range":"(0,5 - 300) V/m"},{"name":"3 MHz - 6 GHz"},{"name":"zakres","range":"(0,8 - 800) V/m"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Natężenie pola elektrycznego w paśmie częstotliwości:\nZakres:\n10 Hz - 400 kHz\nzakres 1 V/m - 50 kV/m\n400 kHz - 3 MHz\nzakres (0,5 - 300) V/m\n3 MHz - 6 GHz\nzakres (0,8 - 800) V/m\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pola elektromagnetyczne Natężenie pola elektrycznego w paśmie częstotliwości:\nZakres:\n10 Hz - 400 kHz\nzakres 1 V/m - 50 kV/m\n400 kHz - 3 MHz\nzakres (0,5 - 300) V/m\n3 MHz - 6 GHz\nzakres (0,8 - 800) V/m\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy - pola elektromagnetyczne Natezenie pola elektrycznego w pasmie czestotliwosci:\nZakres:\n10 Hz - 400 kHz\nzakres 1 V/m - 50 kV/m\n400 kHz - 3 MHz\nzakres (0,5 - 300) V/m\n3 MHz - 6 GHz\nzakres (0,8 - 800) V/m\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":91,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3248","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Środowisko pracy - pola elektromagnetyczne","methodology":"Indukcja magnetyczna w zakresie częstotliwości:","parameters":[{"name":"0Hz zakres","range":"(0,1 - 1000) mT"},{"name":"10 Hz - 400 kHz"},{"name":"zakres","range":"0,1 μT - 19 mT"}],"technique":"Metoda pomiarowa bezpośrednia","techniques":["Metoda pomiarowa bezpośrednia"],"computed":[],"activity":"Indukcja magnetyczna w zakresie częstotliwości:\nZakres:\n0Hz zakres (0,1 - 1000) mT\n10 Hz - 400 kHz\nzakres 0,1 μT - 19 mT\nMetoda pomiarowa bezpośrednia","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pola elektromagnetyczne Indukcja magnetyczna w zakresie częstotliwości:\nZakres:\n0Hz zakres (0,1 - 1000) mT\n10 Hz - 400 kHz\nzakres 0,1 μT - 19 mT\nMetoda pomiarowa bezpośrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy - pola elektromagnetyczne Indukcja magnetyczna w zakresie czestotliwosci:\nZakres:\n0Hz zakres (0,1 - 1000) mT\n10 Hz - 400 kHz\nzakres 0,1 μT - 19 mT\nMetoda pomiarowa bezposrednia PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":92,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3249","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Środowisko pracy - pola elektromagnetyczne","methodology":"Natężenie pola magnetycznego w paśmie częstotliwości:","parameters":[{"name":"27 MHz - 1,0 GHz"},{"name":"zakres","range":"(0,015 - 8,0) A/m"}],"technique":"Metoda pomiarowa bezpośrednia - 800 MHz - 6 GHz (z obliczeń)","techniques":["Metoda pomiarowa bezpośrednia - 800 MHz - 6 GHz (z obliczeń)"],"computed":[],"activity":"Natężenie pola magnetycznego w paśmie częstotliwości:\nZakres:\n27 MHz - 1,0 GHz\nzakres (0,015 - 8,0) A/m\nMetoda pomiarowa bezpośrednia - 800 MHz - 6 GHz (z obliczeń)","reference":"PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","norm_bases":["PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego"],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":"Pomiary pola elektromagnetycznego w środowisku pracy wykonywane dla celów obszaru regulowanego. Potwierdzono kompetencje laboratorium z uwzględnieniem mających zastosowanie wymagań Rozporządzenia Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29.06.2016 r. (Dz. U. z 2018 r. poz. 331)","flexible":false,"search_text":"Środowisko pracy - pola elektromagnetyczne Natężenie pola magnetycznego w paśmie częstotliwości:\nZakres:\n27 MHz - 1,0 GHz\nzakres (0,015 - 8,0) A/m\nMetoda pomiarowa bezpośrednia - 800 MHz - 6 GHz (z obliczeń) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego Srodowisko pracy - pola elektromagnetyczne Natezenie pola magnetycznego w pasmie czestotliwosci:\nZakres:\n27 MHz - 1,0 GHz\nzakres (0,015 - 8,0) A/m\nMetoda pomiarowa bezposrednia - 800 MHz - 6 GHz (z obliczen) PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego","categories":["environment"],"row_index":93,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d324a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność, Produkty rolne, Pasze, Woda, Woda do spożycia przez ludzi","methodology":"Stężenie aktywności radionuklidu 137Cs","parameters":[{"name":"Zakres","range":"(2,0 - 10000) Bq/kg"}],"technique":"Metoda spektrometrii promieniowania gamma","techniques":["Metoda spektrometrii promieniowania gamma"],"computed":[],"activity":"Stężenie aktywności radionuklidu 137Cs\nZakres (2,0 - 10000) Bq/kg\nMetoda spektrometrii promieniowania gamma","reference":"PB-LFR-01 wydanie nr 5 z dnia 09.12.2021 r.","norm_bases":["PB-LFR-01 wydanie nr 5 z dnia 09.12.2021 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Żywność, Produkty rolne, Pasze, Woda, Woda do spożycia przez ludzi Stężenie aktywności radionuklidu 137Cs\nZakres (2,0 - 10000) Bq/kg\nMetoda spektrometrii promieniowania gamma PB-LFR-01 wydanie nr 5 z dnia 09.12.2021 r. Zywnosc, Produkty rolne, Pasze, Woda, Woda do spozycia przez ludzi Stezenie aktywnosci radionuklidu 137Cs\nZakres (2,0 - 10000) Bq/kg\nMetoda spektrometrii promieniowania gamma PB-LFR-01 wydanie nr 5 z dnia 09.12.2021 r.","categories":["food","water"],"row_index":94,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d324b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie aktywności radionuklidu 222Rn","parameters":[{"name":"Zakres","range":"(5 - 200) Bq/l"}],"technique":"Metoda spektrometrii ciekłoscyntylacyjnej","techniques":["Metoda spektrometrii ciekłoscyntylacyjnej"],"computed":[],"activity":"Stężenie aktywności radionuklidu 222Rn\nZakres (5 - 200) Bq/l\nMetoda spektrometrii ciekłoscyntylacyjnej","reference":"PN-EN ISO 13164-4:2023-12","norm_bases":["PN-EN ISO 13164-4:2023-12"],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie aktywności radionuklidu 222Rn\nZakres (5 - 200) Bq/l\nMetoda spektrometrii ciekłoscyntylacyjnej PN-EN ISO 13164-4:2023-12 Woda do spozycia przez ludzi Stezenie aktywnosci radionuklidu 222Rn\nZakres (5 - 200) Bq/l\nMetoda spektrometrii ciekloscyntylacyjnej PN-EN ISO 13164-4:2023-12","categories":["water"],"row_index":95,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d324c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie aktywności radionuklidu 3H","parameters":[{"name":"Zakres","range":"(10 -200) Bq/l"}],"technique":"Metoda spektrometrii ciekłoscyntylacyjnej","techniques":["Metoda spektrometrii ciekłoscyntylacyjnej"],"computed":[],"activity":"Stężenie aktywności radionuklidu 3H\nZakres (10 -200) Bq/l\nMetoda spektrometrii ciekłoscyntylacyjnej","reference":"PN-EN ISO 9698:2019-06","norm_bases":["PN-EN ISO 9698:2019-06"],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie aktywności radionuklidu 3H\nZakres (10 -200) Bq/l\nMetoda spektrometrii ciekłoscyntylacyjnej PN-EN ISO 9698:2019-06 Woda do spozycia przez ludzi Stezenie aktywnosci radionuklidu 3H\nZakres (10 -200) Bq/l\nMetoda spektrometrii ciekloscyntylacyjnej PN-EN ISO 9698:2019-06","categories":["water"],"row_index":96,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d324d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Urządzenia stosowane w radiografii ogólnej cyfrowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-12 wydanie nr 5 z dnia 11.01.2023 r.","norm_bases":["Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)","PB-LFR-12 wydanie nr 5 z dnia 11.01.2023 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane w radiografii ogólnej cyfrowej Testy specjalistyczne Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-12 wydanie nr 5 z dnia 11.01.2023 r. Urzadzenia stosowane w radiografii ogolnej cyfrowej Testy specjalistyczne Zalacznik nr 1 i 2 do Rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-12 wydanie nr 5 z dnia 11.01.2023 r.","categories":["other"],"row_index":97,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d324e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Urządzenia stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii cyfrowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-04 wydanie nr 8 z dnia 10.02.2025 r.","norm_bases":["Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)","PB-LFR-04 wydanie nr 8 z dnia 10.02.2025 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane w stomatologii – aparaty do zdjęć pantomograficznych oraz cefalometrii cyfrowej Testy specjalistyczne Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-04 wydanie nr 8 z dnia 10.02.2025 r. Urzadzenia stosowane w stomatologii – aparaty do zdjec pantomograficznych oraz cefalometrii cyfrowej Testy specjalistyczne Zalacznik nr 1 do Rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-04 wydanie nr 8 z dnia 10.02.2025 r.","categories":["other"],"row_index":98,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d324f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Urządzenia stosowane w stomatologicznej tomografii komputerowej wiązki stożkowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-14 wydanie nr 5 z dnia 11.01.2023 r.","norm_bases":["Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)","PB-LFR-14 wydanie nr 5 z dnia 11.01.2023 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane w stomatologicznej tomografii komputerowej wiązki stożkowej Testy specjalistyczne Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-14 wydanie nr 5 z dnia 11.01.2023 r. Urzadzenia stosowane w stomatologicznej tomografii komputerowej wiazki stozkowej Testy specjalistyczne Zalacznik nr 1 do Rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-14 wydanie nr 5 z dnia 11.01.2023 r.","categories":["other"],"row_index":99,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3250","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Urządzenia stosowane we fluoroskopii i angiografii","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-08 wydanie nr 8 z dnia 11.01.2023 r.","norm_bases":["Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)","PB-LFR-08 wydanie nr 8 z dnia 11.01.2023 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane we fluoroskopii i angiografii Testy specjalistyczne Załącznik nr 1 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-08 wydanie nr 8 z dnia 11.01.2023 r. Urzadzenia stosowane we fluoroskopii i angiografii Testy specjalistyczne Zalacznik nr 1 do Rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-08 wydanie nr 8 z dnia 11.01.2023 r.","categories":["other"],"row_index":100,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3251","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Urządzenia stosowane w mammografii cyfrowej","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-13 wydanie nr 6 z dnia 11.01.2023 r.","norm_bases":["Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)","PB-LFR-13 wydanie nr 6 z dnia 11.01.2023 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Urządzenia stosowane w mammografii cyfrowej Testy specjalistyczne Załącznik nr 1 i 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-13 wydanie nr 6 z dnia 11.01.2023 r. Urzadzenia stosowane w mammografii cyfrowej Testy specjalistyczne Zalacznik nr 1 i 2 do Rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-13 wydanie nr 6 z dnia 11.01.2023 r.","categories":["other"],"row_index":101,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3252","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Monitory stosowane do prezentacji obrazów medycznych","methodology":"Testy specjalistyczne","parameters":[],"technique":null,"techniques":[],"computed":[],"activity":"Testy specjalistyczne","reference":"Załącznik nr 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-15 wydanie nr 5 z dnia 11.01.2023 r.","norm_bases":["Załącznik nr 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)","PB-LFR-15 wydanie nr 5 z dnia 11.01.2023 r."],"lab_section":"Dział Laboratoryjny – obszar higieny radiacyjnej","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Monitory stosowane do prezentacji obrazów medycznych Testy specjalistyczne Załącznik nr 2 do Rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-15 wydanie nr 5 z dnia 11.01.2023 r. Monitory stosowane do prezentacji obrazow medycznych Testy specjalistyczne Zalacznik nr 2 do Rozporzadzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-LFR-15 wydanie nr 5 z dnia 11.01.2023 r.","categories":["other"],"row_index":102,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3253","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kał, szczepy bakteryjne","methodology":"Obecność i identyfikacja pałeczek z rodzaju Salmonella i Shigella","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność i identyfikacja pałeczek z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-LMK-01 wydanie nr 3 z dnia 10.11.2021 r. w oparciu o publikacje metodyczne","norm_bases":["PB-LMK-01 wydanie nr 3 z dnia 10.11.2021 r. w oparciu o publikacje metodyczne"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał, szczepy bakteryjne Obecność i identyfikacja pałeczek z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-LMK-01 wydanie nr 3 z dnia 10.11.2021 r. w oparciu o publikacje metodyczne Kal, szczepy bakteryjne Obecnosc i identyfikacja paleczek z rodzaju Salmonella i Shigella\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-LMK-01 wydanie nr 3 z dnia 10.11.2021 r. w oparciu o publikacje metodyczne","categories":["microbiology"],"row_index":103,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3254","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Szczepy bakteryjne","methodology":"Identyfikacja pałeczek z rodzaju Salmonella","parameters":[],"technique":"Metoda biochemiczna i serologiczna","techniques":["Metoda biochemiczna i serologiczna"],"computed":[],"activity":"Identyfikacja pałeczek z rodzaju Salmonella\nMetoda biochemiczna i serologiczna","reference":"Schemat White’a-Kauffmanna-Le Minora, 2007 ISO/TR 6579-3:2014","norm_bases":["Schemat White’a-Kauffmanna-Le Minora, 2007 ISO/TR 6579-3:2014"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Szczepy bakteryjne Identyfikacja pałeczek z rodzaju Salmonella\nMetoda biochemiczna i serologiczna Schemat White’a-Kauffmanna-Le Minora, 2007 ISO/TR 6579-3:2014 Szczepy bakteryjne Identyfikacja paleczek z rodzaju Salmonella\nMetoda biochemiczna i serologiczna Schemat White’a-Kauffmanna-Le Minora, 2007 ISO/TR 6579-3:2014","categories":["microbiology"],"row_index":104,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3255","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kał","methodology":"Obecność chorobotwórczych i warunkowo chorobotwórczych, Gram-ujemnych pałeczek jelitowych","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność chorobotwórczych i warunkowo chorobotwórczych, Gram-ujemnych pałeczek jelitowych\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"PB-LMK-02 wydanie nr 3 z dnia 22.12.2021 r. w oparciu o publikacje metodyczne","norm_bases":["PB-LMK-02 wydanie nr 3 z dnia 22.12.2021 r. w oparciu o publikacje metodyczne"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał Obecność chorobotwórczych i warunkowo chorobotwórczych, Gram-ujemnych pałeczek jelitowych\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-LMK-02 wydanie nr 3 z dnia 22.12.2021 r. w oparciu o publikacje metodyczne Kal Obecnosc chorobotworczych i warunkowo chorobotworczych, Gram-ujemnych paleczek jelitowych\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym PB-LMK-02 wydanie nr 3 z dnia 22.12.2021 r. w oparciu o publikacje metodyczne","categories":["other"],"row_index":105,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3256","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kał","methodology":"Obecność jaj i cyst pasożytów jelitowych człowieka","parameters":[],"technique":"Metody koproskopowe","techniques":["Metody koproskopowe"],"computed":[],"activity":"Obecność jaj i cyst pasożytów jelitowych człowieka\nMetody koproskopowe","reference":"PB-LMK-05 wydanie nr 3 z dnia 07.12.2016 r. w oparciu o publikacje metodyczne","norm_bases":["PB-LMK-05 wydanie nr 3 z dnia 07.12.2016 r. w oparciu o publikacje metodyczne"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał Obecność jaj i cyst pasożytów jelitowych człowieka\nMetody koproskopowe PB-LMK-05 wydanie nr 3 z dnia 07.12.2016 r. w oparciu o publikacje metodyczne Kal Obecnosc jaj i cyst pasozytow jelitowych czlowieka\nMetody koproskopowe PB-LMK-05 wydanie nr 3 z dnia 07.12.2016 r. w oparciu o publikacje metodyczne","categories":["other"],"row_index":106,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3257","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Biologiczne wskaźniki kontroli skuteczności procesu sterylizacji","methodology":"Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermophilus (Sporal A), Bacillus subtilis (Sporal S)","parameters":[],"technique":"Metoda hodowlana","techniques":["Metoda hodowlana"],"computed":[],"activity":"Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermophilus (Sporal A), Bacillus subtilis (Sporal S)\nMetoda hodowlana","reference":"PB-LMK-03 wydanie nr 3 z dnia 04.01.2021 r. w oparciu o instrukcje producentów stosowanych wskaźników procesu sterylizacji","norm_bases":["PB-LMK-03 wydanie nr 3 z dnia 04.01.2021 r. w oparciu o instrukcje producentów stosowanych wskaźników procesu sterylizacji"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Biologiczne wskaźniki kontroli skuteczności procesu sterylizacji Obecność drobnoustrojów wskaźnikowych Geobacillus stearothermophilus (Sporal A), Bacillus subtilis (Sporal S)\nMetoda hodowlana PB-LMK-03 wydanie nr 3 z dnia 04.01.2021 r. w oparciu o instrukcje producentów stosowanych wskaźników procesu sterylizacji Biologiczne wskazniki kontroli skutecznosci procesu sterylizacji Obecnosc drobnoustrojow wskaznikowych Geobacillus stearothermophilus (Sporal A), Bacillus subtilis (Sporal S)\nMetoda hodowlana PB-LMK-03 wydanie nr 3 z dnia 04.01.2021 r. w oparciu o instrukcje producentow stosowanych wskaznikow procesu sterylizacji","categories":["microbiology"],"row_index":107,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3258","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kał E","methodology":"Obecność antygenów biologicznych czynników chorobotwórczych","parameters":[],"technique":"Metoda immunochromatograficzna (ICR)","techniques":["Metoda immunochromatograficzna (ICR)"],"computed":[],"activity":"Obecność antygenów biologicznych czynników chorobotwórczych\nMetoda immunochromatograficzna (ICR)","reference":"Instrukcje producenta","norm_bases":["Instrukcje producenta"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Kał E Obecność antygenów biologicznych czynników chorobotwórczych\nMetoda immunochromatograficzna (ICR) Instrukcje producenta Kal E Obecnosc antygenow biologicznych czynnikow chorobotworczych\nMetoda immunochromatograficzna (ICR) Instrukcje producenta","categories":["other"],"row_index":108,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3259","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kał E","methodology":"Obecność antygenów biologicznych czynników chorobotwórczych","parameters":[],"technique":"Metoda immunoenzymatyczna (ELISA)","techniques":["Metoda immunoenzymatyczna (ELISA)"],"computed":[],"activity":"Obecność antygenów biologicznych czynników chorobotwórczych\nMetoda immunoenzymatyczna (ELISA)","reference":"Instrukcje producenta","norm_bases":["Instrukcje producenta"],"lab_section":"ODDZIAŁ LABORATORYJNY MIKROBIOLOGII KLINICZNEJ","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Kał E Obecność antygenów biologicznych czynników chorobotwórczych\nMetoda immunoenzymatyczna (ELISA) Instrukcje producenta Kal E Obecnosc antygenow biologicznych czynnikow chorobotworczych\nMetoda immunoenzymatyczna (ELISA) Instrukcje producenta","categories":["other"],"row_index":109,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d325a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 - 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda (w tym woda na plywalni) Metnosc\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":110,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d325b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,020 - 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,020 - 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332: 2001+Ap1:2016-06","norm_bases":["PN-ISO 6332: 2001+Ap1:2016-06"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie żelaza ogólnego\nZakres (0,020 - 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332: 2001+Ap1:2016-06 Woda (w tym woda na plywalni) Stezenie zelaza ogolnego\nZakres (0,020 - 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332: 2001+Ap1:2016-06","categories":["water"],"row_index":111,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d325c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,060 - 1,30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,060 - 1,30) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie jonu amonowego\nZakres (0,060 - 1,30) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda (w tym woda na plywalni) Stezenie jonu amonowego\nZakres (0,060 - 1,30) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":112,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d325d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,020 - 1,312) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,020 - 1,312) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie azotynów\nZakres (0,020 - 1,312) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda (w tym woda na plywalni) Stezenie azotynow\nZakres (0,020 - 1,312) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":113,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d325e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,20 - 110,75) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,20 - 110,75) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-08:1982","norm_bases":["PN-C-04576-08:1982"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie azotanów\nZakres (0,20 - 110,75) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982 Woda (w tym woda na plywalni) Stezenie azotanow\nZakres (0,20 - 110,75) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982","categories":["water"],"row_index":114,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d325f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) pH\nZakres (4,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalni) pH\nZakres (4,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":115,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3260","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(5 - 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 - 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Przewodność elektryczna właściwa\nZakres (5 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda (w tym woda na plywalni) Przewodnosc elektryczna wlasciwa\nZakres (5 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":116,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3261","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(8,0 - 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (8,0 - 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie chlorków\nZakres (8,0 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda (w tym woda na plywalni) Stezenie chlorkow\nZakres (8,0 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":117,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3262","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie glinu/aluminium","parameters":[{"name":"Zakres","range":"(0,020 - 0,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu/aluminium\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04605-02:1992","norm_bases":["PN-C-04605-02:1992"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie glinu/aluminium\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna PN-C-04605-02:1992 Woda (w tym woda na plywalni) Stezenie glinu/aluminium\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna PN-C-04605-02:1992","categories":["water","materials"],"row_index":118,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3263","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 - 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 - 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Indeks nadmanganianowy\nZakres (0,50 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda (w tym woda na plywalni) Indeks nadmanganianowy\nZakres (0,50 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":119,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3264","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,03 - 2,45) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,03 - 2,45) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie ortofosforanów\nZakres (0,03 - 2,45) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 Woda (w tym woda na plywalni) Stezenie ortofosforanow\nZakres (0,03 - 2,45) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":120,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3265","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2,0 - 60) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2,0 - 60) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Barwa\nZakres (2,0 - 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C Woda (w tym woda na plywalni) Barwa\nZakres (2,0 - 60) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","categories":["water"],"row_index":121,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3266","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 - 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":122,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3267","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)","parameters":[{"name":"Zakres","range":"(11 - 700) mg/l CaCO3"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (11 - 700) mg/l CaCO3\nMetoda miareczkowa","reference":"PN-ISO 6059:1999","norm_bases":["PN-ISO 6059:1999"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Sumaryczna zawartość wapnia i magnezu (twardość ogólna)\nZakres (11 - 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999 Woda do spozycia przez ludzi Sumaryczna zawartosc wapnia i magnezu (twardosc ogolna)\nZakres (11 - 700) mg/l CaCO3\nMetoda miareczkowa PN-ISO 6059:1999","categories":["water"],"row_index":123,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3268","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(0,020 - 10,0) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (0,020 - 10,0) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332: 2001+Ap1:2016-06","norm_bases":["PN-ISO 6332: 2001+Ap1:2016-06"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (0,020 - 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332: 2001+Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (0,020 - 10,0) mg/l\nMetoda spektrofotometryczna PN-ISO 6332: 2001+Ap1:2016-06","categories":["water"],"row_index":124,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3269","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,060 - 1,30) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,060 - 1,30) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,060 - 1,30) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,060 - 1,30) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":125,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d326a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotynów","parameters":[{"name":"Zakres","range":"(0,020 - 1,312) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotynów\nZakres (0,020 - 1,312) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN 26777:1999","norm_bases":["PN-EN 26777:1999"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotynów\nZakres (0,020 - 1,312) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999 Woda do spozycia przez ludzi Stezenie azotynow\nZakres (0,020 - 1,312) mg/l\nMetoda spektrofotometryczna PN-EN 26777:1999","categories":["water"],"row_index":126,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d326b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(0,20 - 110,75) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (0,20 - 110,75) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-08:1982","norm_bases":["PN-C-04576-08:1982"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (0,20 - 110,75) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (0,20 - 110,75) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982","categories":["water"],"row_index":127,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d326c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 12,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 12,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres (4,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres (4,0 - 12,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":128,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d326d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(5 - 5000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (5 - 5000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (5 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (5 - 5000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":129,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d326e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(8,0 - 400) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (8,0 - 400) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (8,0 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (8,0 - 400) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":130,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d326f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie glinu/aluminium","parameters":[{"name":"Zakres","range":"(0,020 - 0,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu/aluminium\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04605-02:1992","norm_bases":["PN-C-04605-02:1992"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie glinu/aluminium\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna PN-C-04605-02:1992 Woda do spozycia przez ludzi Stezenie glinu/aluminium\nZakres (0,020 - 0,60) mg/l\nMetoda spektrofotometryczna PN-C-04605-02:1992","categories":["water","materials"],"row_index":131,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3270","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Indeks nadmanganianowy","parameters":[{"name":"Zakres","range":"(0,50 - 10,0) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Indeks nadmanganianowy\nZakres (0,50 - 10,0) mg/l\nMetoda miareczkowa","reference":"PN-EN ISO 8467:2001","norm_bases":["PN-EN ISO 8467:2001"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001 Woda do spozycia przez ludzi Indeks nadmanganianowy\nZakres (0,50 - 10,0) mg/l\nMetoda miareczkowa PN-EN ISO 8467:2001","categories":["water"],"row_index":132,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3271","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,03 - 2,45) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,03 - 2,45) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie ortofosforanów\nZakres (0,03 - 2,45) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 Woda do spozycia przez ludzi Stezenie ortofosforanow\nZakres (0,03 - 2,45) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":133,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3272","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(2,0 - 60) mg/lPt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (2,0 - 60) mg/lPt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (2,0 - 60) mg/lPt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (2,0 - 60) mg/lPt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","categories":["water"],"row_index":134,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3273","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Kał","methodology":"Obecność pałeczek z rodzaju, Salmonella i Shigella","parameters":[],"technique":"Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","techniques":["Metoda hodowlana uzupełniona testami biochemicznymi i serologicznymi"],"computed":[],"activity":"Obecność pałeczek z rodzaju, Salmonella i Shigella\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi","reference":"PB-LZT-10 wydanie nr 4 z dnia 11.02.2025 r. w oparciu o publikacje metodyczne","norm_bases":["PB-LZT-10 wydanie nr 4 z dnia 11.02.2025 r. w oparciu o publikacje metodyczne"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Kał Obecność pałeczek z rodzaju, Salmonella i Shigella\nMetoda hodowlana uzupełniona testami biochemicznymi i serologicznymi PB-LZT-10 wydanie nr 4 z dnia 11.02.2025 r. w oparciu o publikacje metodyczne Kal Obecnosc paleczek z rodzaju, Salmonella i Shigella\nMetoda hodowlana uzupelniona testami biochemicznymi i serologicznymi PB-LZT-10 wydanie nr 4 z dnia 11.02.2025 r. w oparciu o publikacje metodyczne","categories":["microbiology"],"row_index":135,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3274","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda filtracji membranowej Normy Woda E Liczba drobnoustrojow\nMetoda filtracji membranowej Normy","categories":["water","microbiology"],"row_index":136,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3275","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Woda E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["water","microbiology"],"row_index":137,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3276","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda NPL","techniques":["Metoda NPL"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda NPL","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda NPL Normy Woda E Liczba drobnoustrojow\nMetoda NPL Normy","categories":["water","microbiology"],"row_index":138,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3277","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["food","microbiology"],"row_index":139,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3278","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy","categories":["food","microbiology"],"row_index":140,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3279","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Zywnosc E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["food","microbiology"],"row_index":141,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d327a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy","norm_bases":["Normy"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Zywnosc E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy","categories":["food","microbiology"],"row_index":142,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d327b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość azotu","parameters":[{"name":"Zakres","range":"(0,19 - 29,8) %"},{"name":"Zawartość białka (z obliczeń)"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość azotu\nZakres:\nZakres (0,19 - 29,8) %\nZawartość białka (z obliczeń)\nMetoda miareczkowa","reference":"PB-LZT-19 wydanie nr 2 z dnia 20.01.2021 r.","norm_bases":["PB-LZT-19 wydanie nr 2 z dnia 20.01.2021 r."],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość azotu\nZakres:\nZakres (0,19 - 29,8) %\nZawartość białka (z obliczeń)\nMetoda miareczkowa PB-LZT-19 wydanie nr 2 z dnia 20.01.2021 r. Mieso i przetwory miesne Zawartosc azotu\nZakres:\nZakres (0,19 - 29,8) %\nZawartosc bialka (z obliczen)\nMetoda miareczkowa PB-LZT-19 wydanie nr 2 z dnia 20.01.2021 r.","categories":["food"],"row_index":143,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d327c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Owoce, warzywa i ich przetwory","methodology":"Zawartość azotanów","parameters":[{"name":"NaNO3","range":"(10,20 - 9233,8) mg/kg"},{"name":"NO3−","range":"(7,43 - 8321,0) mg/kg"},{"name":"Zawartość azotynów NaNO2","range":"(1,30 - 1480) mg/kg"},{"name":"NO2−","range":"(0,89 - 1000,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotanów\nZakres:\nNaNO3 (10,20 - 9233,8) mg/kg\nNO3− (7,43 - 8321,0) mg/kg\nZawartość azotynów NaNO2 (1,30 - 1480) mg/kg\nNO2− (0,89 - 1000,0) mg/kg\nMetoda spektrofotometryczna","reference":"PN-A-75112:1992 pkt.3","norm_bases":["PN-A-75112:1992 pkt.3"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce, warzywa i ich przetwory Zawartość azotanów\nZakres:\nNaNO3 (10,20 - 9233,8) mg/kg\nNO3− (7,43 - 8321,0) mg/kg\nZawartość azotynów NaNO2 (1,30 - 1480) mg/kg\nNO2− (0,89 - 1000,0) mg/kg\nMetoda spektrofotometryczna PN-A-75112:1992 pkt.3 Owoce, warzywa i ich przetwory Zawartosc azotanow\nZakres:\nNaNO3 (10,20 - 9233,8) mg/kg\nNO3− (7,43 - 8321,0) mg/kg\nZawartosc azotynow NaNO2 (1,30 - 1480) mg/kg\nNO2− (0,89 - 1000,0) mg/kg\nMetoda spektrofotometryczna PN-A-75112:1992 pkt.3","categories":["other"],"row_index":144,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d327d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Owoce, warzywa i ich przetwory","methodology":"Zawartość dwutlenku siarki","parameters":[{"name":"Zakres","range":"(3,78 - 3000) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość dwutlenku siarki\nZakres (3,78 - 3000) mg/kg\nMetoda miareczkowa","reference":"PN-A-75101-23: 1990 pkt.3 +Az2:2002","norm_bases":["PN-A-75101-23: 1990 pkt.3 +Az2:2002"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Owoce, warzywa i ich przetwory Zawartość dwutlenku siarki\nZakres (3,78 - 3000) mg/kg\nMetoda miareczkowa PN-A-75101-23: 1990 pkt.3 +Az2:2002 Owoce, warzywa i ich przetwory Zawartosc dwutlenku siarki\nZakres (3,78 - 3000) mg/kg\nMetoda miareczkowa PN-A-75101-23: 1990 pkt.3 +Az2:2002","categories":["other"],"row_index":145,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d327e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mleko i przetwory mleczne","methodology":"Zawartość azotanów","parameters":[{"name":"NO3−","range":"(3,44 - 540,0) mg/kg"},{"name":"NaNO3","range":"(4,71 - 739,8) mg/kg"},{"name":"Zawartość azotynów NO2−","range":"(0,31 - 80,0) mg/kg"},{"name":"NaNO2","range":"(0,46 - 118,4) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotanów\nZakres:\nNO3− (3,44 - 540,0) mg/kg\nNaNO3 (4,71 - 739,8) mg/kg\nZawartość azotynów NO2− (0,31 - 80,0) mg/kg\nNaNO2 (0,46 - 118,4) mg/kg\nMetoda spektrofotometryczna","reference":"PN-EN ISO 14673-1:2004+Ap1:2007","norm_bases":["PN-EN ISO 14673-1:2004+Ap1:2007"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mleko i przetwory mleczne Zawartość azotanów\nZakres:\nNO3− (3,44 - 540,0) mg/kg\nNaNO3 (4,71 - 739,8) mg/kg\nZawartość azotynów NO2− (0,31 - 80,0) mg/kg\nNaNO2 (0,46 - 118,4) mg/kg\nMetoda spektrofotometryczna PN-EN ISO 14673-1:2004+Ap1:2007 Mleko i przetwory mleczne Zawartosc azotanow\nZakres:\nNO3− (3,44 - 540,0) mg/kg\nNaNO3 (4,71 - 739,8) mg/kg\nZawartosc azotynow NO2− (0,31 - 80,0) mg/kg\nNaNO2 (0,46 - 118,4) mg/kg\nMetoda spektrofotometryczna PN-EN ISO 14673-1:2004+Ap1:2007","categories":["food"],"row_index":146,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d327f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość azotanów","parameters":[{"name":"NaNO3","range":"(12,2 - 2197,5) mg/kg"},{"name":"NO3−","range":"(8,9 – 1604,2) mg/kg"},{"name":"Zawartość azotynów NaNO2","range":"(4,0 - 300,0) mg/kg"},{"name":"NO2−","range":"(2,7 - 201,0) mg/kg"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość azotanów\nZakres:\nNaNO3 (12,2 - 2197,5) mg/kg\nNO3− (8,9 – 1604,2) mg/kg\nZawartość azotynów NaNO2 (4,0 - 300,0) mg/kg\nNO2− (2,7 - 201,0) mg/kg\nMetoda spektrofotometryczna","reference":"PN-A-82114:1974","norm_bases":["PN-A-82114:1974"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość azotanów\nZakres:\nNaNO3 (12,2 - 2197,5) mg/kg\nNO3− (8,9 – 1604,2) mg/kg\nZawartość azotynów NaNO2 (4,0 - 300,0) mg/kg\nNO2− (2,7 - 201,0) mg/kg\nMetoda spektrofotometryczna PN-A-82114:1974 Mieso i przetwory miesne Zawartosc azotanow\nZakres:\nNaNO3 (12,2 - 2197,5) mg/kg\nNO3− (8,9 – 1604,2) mg/kg\nZawartosc azotynow NaNO2 (4,0 - 300,0) mg/kg\nNO2− (2,7 - 201,0) mg/kg\nMetoda spektrofotometryczna PN-A-82114:1974","categories":["food"],"row_index":147,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3280","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Mięso i przetwory mięsne","methodology":"Zawartość fosforu ogólnego i dodanego Zawartość fosforu ogólnego","parameters":[{"name":"Zakres","range":"(140 - 13000) mg/kg P2O5"},{"name":"Zawartość fosforu dodanego (z obliczeń)"}],"technique":"Metoda wagowa","techniques":["Metoda wagowa"],"computed":[],"activity":"Zawartość fosforu ogólnego i dodanego Zawartość fosforu ogólnego\nZakres:\nZakres (140 - 13000) mg/kg P2O5\nZawartość fosforu dodanego (z obliczeń)\nMetoda wagowa","reference":"PN-A-82060:1999","norm_bases":["PN-A-82060:1999"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Mięso i przetwory mięsne Zawartość fosforu ogólnego i dodanego Zawartość fosforu ogólnego\nZakres:\nZakres (140 - 13000) mg/kg P2O5\nZawartość fosforu dodanego (z obliczeń)\nMetoda wagowa PN-A-82060:1999 Mieso i przetwory miesne Zawartosc fosforu ogolnego i dodanego Zawartosc fosforu ogolnego\nZakres:\nZakres (140 - 13000) mg/kg P2O5\nZawartosc fosforu dodanego (z obliczen)\nMetoda wagowa PN-A-82060:1999","categories":["food"],"row_index":148,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3281","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Sól kuchenna","methodology":"Zawartość jodku potasowego","parameters":[{"name":"Zakres","range":"(12,83 - 173) mg/kg"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Zawartość jodku potasowego\nZakres (12,83 - 173) mg/kg\nMetoda miareczkowa","reference":"PN-C-84081-34:1980","norm_bases":["PN-C-84081-34:1980"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Sól kuchenna Zawartość jodku potasowego\nZakres (12,83 - 173) mg/kg\nMetoda miareczkowa PN-C-84081-34:1980 Sol kuchenna Zawartosc jodku potasowego\nZakres (12,83 - 173) mg/kg\nMetoda miareczkowa PN-C-84081-34:1980","categories":["other"],"row_index":149,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3282","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Ryby, owoce morza i ich przetwory, Przetwory zbożowo-mączne i wyroby ciastkarskie, Przetwory owocowo-warzywne, Tłuszcze roślinne i zwierzęce, Środki spożywcze specjalnego przeznaczenia, Koncentraty spożywcze, Suplementy diety, Wyroby garmażeryjne i kulinarne, Musztardy, sosy, Produkty mleczne, Napoje bezalkoholowe","methodology":"Zawartość kwasu benzoesowego, kwasu sorbowego,","parameters":[{"name":"Kwas benzoesowy"},{"name":"Zakres","range":"(10 - 10000) mg/l"},{"name":"Zakres","range":"(10 - 10000) mg/kg"},{"name":"Kwas sorbowy (15 - 10000 mg/l","range":"(15 - 10000) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)"],"computed":[],"activity":"Zawartość kwasu benzoesowego, kwasu sorbowego,\nZakres:\nKwas benzoesowy\nZakres (10 - 10000) mg/l\nZakres (10 - 10000) mg/kg\nKwas sorbowy (15 - 10000 mg/l (15 - 10000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","reference":"PN-EN 12856:2002","norm_bases":["PN-EN 12856:2002"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby, owoce morza i ich przetwory, Przetwory zbożowo-mączne i wyroby ciastkarskie, Przetwory owocowo-warzywne, Tłuszcze roślinne i zwierzęce, Środki spożywcze specjalnego przeznaczenia, Koncentraty spożywcze, Suplementy diety, Wyroby garmażeryjne i kulinarne, Musztardy, sosy, Produkty mleczne, Napoje bezalkoholowe Zawartość kwasu benzoesowego, kwasu sorbowego,\nZakres:\nKwas benzoesowy\nZakres (10 - 10000) mg/l\nZakres (10 - 10000) mg/kg\nKwas sorbowy (15 - 10000 mg/l (15 - 10000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS) PN-EN 12856:2002 Ryby, owoce morza i ich przetwory, Przetwory zbozowo-maczne i wyroby ciastkarskie, Przetwory owocowo-warzywne, Tluszcze roslinne i zwierzece, Srodki spozywcze specjalnego przeznaczenia, Koncentraty spozywcze, Suplementy diety, Wyroby garmazeryjne i kulinarne, Musztardy, sosy, Produkty mleczne, Napoje bezalkoholowe Zawartosc kwasu benzoesowego, kwasu sorbowego,\nZakres:\nKwas benzoesowy\nZakres (10 - 10000) mg/l\nZakres (10 - 10000) mg/kg\nKwas sorbowy (15 - 10000 mg/l (15 - 10000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV-VIS) PN-EN 12856:2002","categories":["food","pharma"],"row_index":150,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3283","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Ryby, owoce morza i ich przetwory, Przetwory zbożowo-mączne i wyroby ciastkarskie, Przetwory owocowo-warzywne, Środki spożywcze specjalnego przeznaczenia, Koncentraty spożywcze, Suplementy diety, Wyroby garmażeryjne i kulinarne, Musztardy, sosy, Produkty mleczne, Napoje bezalkoholowe","methodology":"Zawartość aspartamu, acesulfamu-K, sacharyny","parameters":[{"name":"Aspartam"},{"name":"Zakres","range":"(25 - 10000) mg/l"},{"name":"Zakres","range":"(25 - 10000) mg/kg"},{"name":"Acesulfam-K","range":"(10 - 10000) mg/l"},{"name":"(10 - 10000) mg/kg"},{"name":"Sacharyna","range":"(5 - 10000) mg/l"},{"name":"(5 - 10000) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)"],"computed":[],"activity":"Zawartość aspartamu, acesulfamu-K, sacharyny\nZakres:\nAspartam\nZakres (25 - 10000) mg/l\nZakres (25 - 10000) mg/kg\nAcesulfam-K (10 - 10000) mg/l\n(10 - 10000) mg/kg\nSacharyna (5 - 10000) mg/l\n(5 - 10000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","reference":"PN-EN 12856:2002","norm_bases":["PN-EN 12856:2002"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Ryby, owoce morza i ich przetwory, Przetwory zbożowo-mączne i wyroby ciastkarskie, Przetwory owocowo-warzywne, Środki spożywcze specjalnego przeznaczenia, Koncentraty spożywcze, Suplementy diety, Wyroby garmażeryjne i kulinarne, Musztardy, sosy, Produkty mleczne, Napoje bezalkoholowe Zawartość aspartamu, acesulfamu-K, sacharyny\nZakres:\nAspartam\nZakres (25 - 10000) mg/l\nZakres (25 - 10000) mg/kg\nAcesulfam-K (10 - 10000) mg/l\n(10 - 10000) mg/kg\nSacharyna (5 - 10000) mg/l\n(5 - 10000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS) PN-EN 12856:2002 Ryby, owoce morza i ich przetwory, Przetwory zbozowo-maczne i wyroby ciastkarskie, Przetwory owocowo-warzywne, Srodki spozywcze specjalnego przeznaczenia, Koncentraty spozywcze, Suplementy diety, Wyroby garmazeryjne i kulinarne, Musztardy, sosy, Produkty mleczne, Napoje bezalkoholowe Zawartosc aspartamu, acesulfamu-K, sacharyny\nZakres:\nAspartam\nZakres (25 - 10000) mg/l\nZakres (25 - 10000) mg/kg\nAcesulfam-K (10 - 10000) mg/l\n(10 - 10000) mg/kg\nSacharyna (5 - 10000) mg/l\n(5 - 10000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV-VIS) PN-EN 12856:2002","categories":["food","pharma"],"row_index":151,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3284","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Przetwory zbożowo-mączne i wyroby ciastkarskie, Środki spożywcze specjalnego przeznaczenia, Koncentraty spożywcze, Suplementy diety, Wyroby garmażeryjne i kulinarne, Produkty mleczne, Napoje bezalkoholowe","methodology":"Zawartość kofeiny","parameters":[{"name":"Zakres","range":"(10 - 10000) mg/l"},{"name":"Zakres","range":"(10 - 30000) mg/kg"}],"technique":"Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","techniques":["Metoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)"],"computed":[],"activity":"Zawartość kofeiny\nZakres:\nZakres (10 - 10000) mg/l\nZakres (10 - 30000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS)","reference":"PN-EN 12856:2002","norm_bases":["PN-EN 12856:2002"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Przetwory zbożowo-mączne i wyroby ciastkarskie, Środki spożywcze specjalnego przeznaczenia, Koncentraty spożywcze, Suplementy diety, Wyroby garmażeryjne i kulinarne, Produkty mleczne, Napoje bezalkoholowe Zawartość kofeiny\nZakres:\nZakres (10 - 10000) mg/l\nZakres (10 - 30000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcją spektrofotometryczną (HPLC-UV-VIS) PN-EN 12856:2002 Przetwory zbozowo-maczne i wyroby ciastkarskie, Srodki spozywcze specjalnego przeznaczenia, Koncentraty spozywcze, Suplementy diety, Wyroby garmazeryjne i kulinarne, Produkty mleczne, Napoje bezalkoholowe Zawartosc kofeiny\nZakres:\nZakres (10 - 10000) mg/l\nZakres (10 - 30000) mg/kg\nMetoda wysokosprawnej chromatografii cieczowej z detekcja spektrofotometryczna (HPLC-UV-VIS) PN-EN 12856:2002","categories":["food","pharma"],"row_index":152,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3285","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Napoje spirytusowe","methodology":"Zawartość cyjanowodoru","parameters":[{"name":"Zakres","range":"(0,0088 - 13) g/hl 100%"},{"name":"alkoholu etylowego"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Zawartość cyjanowodoru\nZakres:\nZakres (0,0088 - 13) g/hl 100%\nalkoholu etylowego\nMetoda spektrofotometryczna","reference":"PN-A-79529-13:2005 pkt. 5.3","norm_bases":["PN-A-79529-13:2005 pkt. 5.3"],"lab_section":"Oddział Laboratoryjny w Tarnowie","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Napoje spirytusowe Zawartość cyjanowodoru\nZakres:\nZakres (0,0088 - 13) g/hl 100%\nalkoholu etylowego\nMetoda spektrofotometryczna PN-A-79529-13:2005 pkt. 5.3 Napoje spirytusowe Zawartosc cyjanowodoru\nZakres:\nZakres (0,0088 - 13) g/hl 100%\nalkoholu etylowego\nMetoda spektrofotometryczna PN-A-79529-13:2005 pkt. 5.3","categories":["food"],"row_index":153,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3286","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda (w tym woda na plywalni) pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":154,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3287","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(30 - 750) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (30 - 750) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie żelaza ogólnego\nZakres (30 - 750) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda (w tym woda na plywalni) Stezenie zelaza ogolnego\nZakres (30 - 750) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":155,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3288","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1,00 - 110) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (1,00 - 110) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-08:1982","norm_bases":["PN-C-04576-08:1982"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie azotanów\nZakres (1,00 - 110) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982 Woda (w tym woda na plywalni) Stezenie azotanow\nZakres (1,00 - 110) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982","categories":["water"],"row_index":156,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3289","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(88 - 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (88 - 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Przewodność elektryczna właściwa\nZakres (88 - 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda (w tym woda na plywalni) Przewodnosc elektryczna wlasciwa\nZakres (88 - 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":157,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d328a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,070 - 1,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,070 - 1,50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie jonu amonowego\nZakres (0,070 - 1,50) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda (w tym woda na plywalni) Stezenie jonu amonowego\nZakres (0,070 - 1,50) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":158,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d328b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 - 680) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 - 680) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Stężenie chlorków\nZakres (5,00 - 680) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda (w tym woda na plywalni) Stezenie chlorkow\nZakres (5,00 - 680) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":159,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d328c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda (w tym woda na pływalni)","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 - 40) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 - 40) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda (w tym woda na pływalni) Barwa\nZakres (5 - 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C Woda (w tym woda na plywalni) Barwa\nZakres (5 - 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","categories":["water"],"row_index":160,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d328d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"pH","parameters":[{"name":"Zakres","range":"(4,0 - 10,0)"}],"technique":"Metoda potencjometryczna","techniques":["Metoda potencjometryczna"],"computed":[],"activity":"pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna","reference":"PN-EN ISO 10523:2012","norm_bases":["PN-EN ISO 10523:2012"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012 Woda do spozycia przez ludzi pH\nZakres (4,0 - 10,0)\nMetoda potencjometryczna PN-EN ISO 10523:2012","categories":["water"],"row_index":161,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d328e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie żelaza ogólnego","parameters":[{"name":"Zakres","range":"(30 – 8000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie żelaza ogólnego\nZakres (30 – 8000) μg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 6332:2001+Ap1:2016-06","norm_bases":["PN-ISO 6332:2001+Ap1:2016-06"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie żelaza ogólnego\nZakres (30 – 8000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06 Woda do spozycia przez ludzi Stezenie zelaza ogolnego\nZakres (30 – 8000) μg/l\nMetoda spektrofotometryczna PN-ISO 6332:2001+Ap1:2016-06","categories":["water"],"row_index":162,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d328f","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie azotanów","parameters":[{"name":"Zakres","range":"(1,00 - 110) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie azotanów\nZakres (1,00 - 110) mg/l\nMetoda spektrofotometryczna","reference":"PN-C-04576-08:1982","norm_bases":["PN-C-04576-08:1982"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie azotanów\nZakres (1,00 - 110) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982 Woda do spozycia przez ludzi Stezenie azotanow\nZakres (1,00 - 110) mg/l\nMetoda spektrofotometryczna PN-C-04576-08:1982","categories":["water"],"row_index":163,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3290","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Mętność","parameters":[{"name":"Zakres","range":"(0,10 - 100) NTU"}],"technique":"Metoda nefelometryczna","techniques":["Metoda nefelometryczna"],"computed":[],"activity":"Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna","reference":"PN-EN ISO 7027-1:2016-09","norm_bases":["PN-EN ISO 7027-1:2016-09"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Mętność\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09 Woda do spozycia przez ludzi Metnosc\nZakres (0,10 - 100) NTU\nMetoda nefelometryczna PN-EN ISO 7027-1:2016-09","categories":["water"],"row_index":164,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3291","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie glinu/aluminium","parameters":[{"name":"Zakres","range":"(40 - 1000) μg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie glinu/aluminium\nZakres (40 - 1000) μg/l\nMetoda spektrofotometryczna","reference":"PN-C-04605-02:1992","norm_bases":["PN-C-04605-02:1992"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie glinu/aluminium\nZakres (40 - 1000) μg/l\nMetoda spektrofotometryczna PN-C-04605-02:1992 Woda do spozycia przez ludzi Stezenie glinu/aluminium\nZakres (40 - 1000) μg/l\nMetoda spektrofotometryczna PN-C-04605-02:1992","categories":["water","materials"],"row_index":165,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3292","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Przewodność elektryczna właściwa","parameters":[{"name":"Zakres","range":"(88 - 3000) μS/cm"}],"technique":"Metoda konduktometryczna","techniques":["Metoda konduktometryczna"],"computed":[],"activity":"Przewodność elektryczna właściwa\nZakres (88 - 3000) μS/cm\nMetoda konduktometryczna","reference":"PN-EN 27888:1999","norm_bases":["PN-EN 27888:1999"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Przewodność elektryczna właściwa\nZakres (88 - 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999 Woda do spozycia przez ludzi Przewodnosc elektryczna wlasciwa\nZakres (88 - 3000) μS/cm\nMetoda konduktometryczna PN-EN 27888:1999","categories":["water"],"row_index":166,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3293","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie jonu amonowego","parameters":[{"name":"Zakres","range":"(0,070 - 1,50) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie jonu amonowego\nZakres (0,070 - 1,50) mg/l\nMetoda spektrofotometryczna","reference":"PN-ISO 7150-1:2002","norm_bases":["PN-ISO 7150-1:2002"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie jonu amonowego\nZakres (0,070 - 1,50) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002 Woda do spozycia przez ludzi Stezenie jonu amonowego\nZakres (0,070 - 1,50) mg/l\nMetoda spektrofotometryczna PN-ISO 7150-1:2002","categories":["water"],"row_index":167,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3294","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie chlorków","parameters":[{"name":"Zakres","range":"(5,00 - 680) mg/l"}],"technique":"Metoda miareczkowa","techniques":["Metoda miareczkowa"],"computed":[],"activity":"Stężenie chlorków\nZakres (5,00 - 680) mg/l\nMetoda miareczkowa","reference":"PN-ISO 9297:1994","norm_bases":["PN-ISO 9297:1994"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie chlorków\nZakres (5,00 - 680) mg/l\nMetoda miareczkowa PN-ISO 9297:1994 Woda do spozycia przez ludzi Stezenie chlorkow\nZakres (5,00 - 680) mg/l\nMetoda miareczkowa PN-ISO 9297:1994","categories":["water"],"row_index":168,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3295","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Barwa","parameters":[{"name":"Zakres","range":"(5 - 40) mg/l Pt"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Barwa\nZakres (5 - 40) mg/l Pt\nMetoda spektrofotometryczna","reference":"PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","norm_bases":["PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Barwa\nZakres (5 - 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C Woda do spozycia przez ludzi Barwa\nZakres (5 - 40) mg/l Pt\nMetoda spektrofotometryczna PN-EN ISO 7887:2012 +Ap1:2015-06 Metoda C","categories":["water"],"row_index":169,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3296","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda do spożycia przez ludzi","methodology":"Stężenie ortofosforanów","parameters":[{"name":"Zakres","range":"(0,040 - 1,60) mg/l"}],"technique":"Metoda spektrofotometryczna","techniques":["Metoda spektrofotometryczna"],"computed":[],"activity":"Stężenie ortofosforanów\nZakres (0,040 - 1,60) mg/l\nMetoda spektrofotometryczna","reference":"PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","norm_bases":["PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":null,"flexible":false,"search_text":"Woda do spożycia przez ludzi Stężenie ortofosforanów\nZakres (0,040 - 1,60) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010 Woda do spozycia przez ludzi Stezenie ortofosforanow\nZakres (0,040 - 1,60) mg/l\nMetoda spektrofotometryczna PN-EN ISO 6878:2006 pkt.4 +Ap1:2010+Ap2:2010","categories":["water"],"row_index":170,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3297","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Woda E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["water","microbiology"],"row_index":171,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3298","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda filtracji membranowej","techniques":["Metoda filtracji membranowej"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda filtracji membranowej","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda filtracji membranowej Normy Woda E Liczba drobnoustrojow\nMetoda filtracji membranowej Normy","categories":["water","microbiology"],"row_index":172,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d3299","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Woda E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["water","microbiology"],"row_index":173,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d329a","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Woda E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda zminiaturyzowana, NPL","techniques":["Metoda zminiaturyzowana, NPL"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda zminiaturyzowana, NPL","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Woda E Liczba drobnoustrojów\nMetoda zminiaturyzowana, NPL Normy Woda E Liczba drobnoustrojow\nMetoda zminiaturyzowana, NPL Normy","categories":["water","microbiology"],"row_index":174,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d329b","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym i serologicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym i serologicznym Normy","categories":["food","microbiology"],"row_index":175,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d329c","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Obecność drobnoustrojów","parameters":[],"technique":"Metoda hodowlana z potwierdzeniem biochemicznym","techniques":["Metoda hodowlana z potwierdzeniem biochemicznym"],"computed":[],"activity":"Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Obecność drobnoustrojów\nMetoda hodowlana z potwierdzeniem biochemicznym Normy Zywnosc E Obecnosc drobnoustrojow\nMetoda hodowlana z potwierdzeniem biochemicznym Normy","categories":["food","microbiology"],"row_index":176,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d329d","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew wgłębny)","techniques":["Metoda płytkowa (posiew wgłębny)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba drobnoustrojów\nMetoda płytkowa (posiew wgłębny) Normy Zywnosc E Liczba drobnoustrojow\nMetoda plytkowa (posiew wglebny) Normy","categories":["food","microbiology"],"row_index":177,"parse_version":4,"parse_source":"agent-claude-code"},{"_id":"6a9a16dd9dc807729a5d329e","lab_id":"69ad52a3de79e566650fb312","country":"PL","accr_number":"AB 601","accr_body":"PCA","test_object":"Żywność E","methodology":"Liczba drobnoustrojów","parameters":[],"technique":"Metoda płytkowa (posiew powierzchniowy)","techniques":["Metoda płytkowa (posiew powierzchniowy)"],"computed":[],"activity":"Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy)","reference":"Normy","norm_bases":["Normy"],"lab_section":"ODDZIAŁ LABORATORYJNY w WADOWICACH","lab_address":null,"regulatory_area":"E-Elastyczny zakres akredytacji. Elastyczność zakresu obejmuje elementy wskazane w dokumencie DA-10 dla zakresu akredytacji laboratoriów badawczych. Lista badań prowadzonych w ramach elastycznego zakresu akredytacji jest udostępniana publicznie przez akredytowany podmiot.","flexible":false,"search_text":"Żywność E Liczba drobnoustrojów\nMetoda płytkowa (posiew powierzchniowy) Normy Zywnosc E Liczba drobnoustrojow\nMetoda plytkowa (posiew powierzchniowy) Normy","categories":["food","microbiology"],"row_index":178,"parse_version":4,"parse_source":"agent-claude-code"}],"has_pdf":true}