🇵🇱 POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA PL

PCA AB 582 • Wałbrzych, Poland • 42 methods

Water & wastewaterEnvironmentMicrobiology

POWIATOWA STACJA SANITARNO-EPIDEMIOLOGICZNA is a laboratory accredited by PCA under number AB 582 (Wałbrzych, Poland). Its accreditation scope covers 42 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Water, water intended for human consumption, Workplace environment - air, Water, Water intended for human consumption, Swimming pool water. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Direct measurement method.

At a glance

  • Accreditation number: PCA AB 582
  • Methods in scope: 42
  • Types of test objects: 11
  • Techniques used: 15
  • City: Wałbrzych, Poland
Accreditation number
AB 582
Accreditation body
PCA
Address
W WAŁBRZYCHU, ul. Armii Krajowej 35 C, 58-302 Wałbrzych
City
Wałbrzych, Poland

What this laboratory tests (11)

Analytical techniques used (15)

Accreditation scope — test methods (42)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
2 Water, Water intended for human consumption Total microorganism count Plate method, pour plate PN-EN ISO 6222:2004
3 Water, Water intended for human consumption Coliform bacteria count, Escherichia coli Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04
4 Water, Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2:2004
5 Water, Water intended for human consumption Most probable number of coliform bacteria, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
6 Water, Water intended for human consumption Clostridium perfringens count (including spores) Membrane filtration method PN-EN ISO 14189:2016-10
7 Water, Water intended for human consumption Count of bacteria of the genus Legionella
Matrix A Procedure 5 (medium A), 7 (medium C - GVPC) Matrix B Procedure 7, GVPC medium
Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12
8 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method Metodyka NIZP PZH ZHK:2007
9 Swimming pool water Most probable number of coliform bacteria, Escherichia coli MPN method PN-EN ISO 9308-2:2014-06
10 Swimming pool water Most probable number, Pseudomonas aeruginosa MPN method PN-EN ISO 16266-2:2022-04
11 Swimming pool water Total microorganism count Plate method, pour plate PN-EN ISO 6222:2004
12 Swimming pool water Escherichia coli count Membrane filtration method PN-EN ISO 9308-1:2014-12 | PN-EN ISO 9308-1:2014-12/ A1:2017-04
13 Swimming pool water Count of bacteria of the genus Legionella
Matrix A Procedure 5 (medium A), 7 (medium C - GVPC) Matrix B Procedure 7, GVPC medium
Membrane filtration method PN-EN ISO 11731:2017-08 | PN-EN ISO 11731:2017-08/ Ap1:2019-12
14 Faeces, rectal swab, Microbial strains Presence and identification of rods, Salmonella, Shigella Culture method with biochemical and serological confirmation PB-LM/L-09 wersja 07 z dnia 08.11.2021 r.
15 Water, water intended for human consumption Nitrite concentration
Range (0,060 - 0,80) mg/l
Spectrophotometric method PN-EN 26777:1999
16 Water, water intended for human consumption Iron concentration
Range (0,020 - 0,60) mg/l
Spectrophotometric method PN-ISO 6332:2001 | PN-ISO 6332:2001/Ap1:2016-06
17 Water, water intended for human consumption Manganese concentration
Range (0,030 - 0,60) mg/l
Spectrophotometric method PN-92/C-04590/03
18 Water, water intended for human consumption Hardness (total concentration of calcium and magnesium)
Range (20 - 500) mg/l
Titrimetric method PN-ISO 6059:1999
19 Water, water intended for human consumption Chloride concentration
Range (5,0 - 300) mg/l
Titrimetric method PN-ISO 9297:1994
20 Water, water intended for human consumption Electrical conductivity
Range (100 - 2500) μS/cm
Conductometric method PN-EN 27888:1999
21 Water, water intended for human consumption Ammonium ion concentration
Range (0,10 - 0,80) mg/l
Spectrophotometric method PN-ISO 7150-1:2002
22 Water, water intended for human consumption Fluoride concentration
Range (0,20 - 1,6) mg/l
Spectrophotometric method PN-75/C-04588/01
23 Water, water intended for human consumption Colour
Range (5 - 70) mg/l Pt
Visual method PN-EN ISO 7887:2012 pkt. 7
24 Water, water intended for human consumption Boron concentration
Range (0,20 – 1,2) mg/l
Spectrophotometric method PB-LCh/W-36 wersja 02 z dnia 08.11.2021 r.
25 Water (including swimming pool water), water intended for human consumption Nitrate concentration
Range (0,50 - 50) mg/l
Spectrophotometric method PN-82/C-04576.08
26 Water (including swimming pool water), water intended for human consumption pH
Range 2,0 – 10,0
Potentiometric method PN-EN ISO 10523:2012
27 Water (including swimming pool water), water intended for human consumption Turbidity
Range (0,10 - 40) NTU
Nephelometric method PN-EN ISO 7027-1:2016-09
28 Water (including swimming pool water), water intended for human consumption Permanganate index
Range (0,50 - 10) mg/l
Titrimetric method PN-EN ISO 8467:2001
29 Workplace environment - air Sampling for the assessment of occupational exposure to:
dust agents inhalable fraction respirable fraction inorganic substances respirable fraction metals and their compounds, including inhalable fraction respirable fraction
Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
30 Workplace environment - air Sampling for the assessment of occupational exposure to:
inorganic substances
Personal dosimetry method; Stationary method PN-Z-04008-7:2002+Az1:2004
31 Workplace environment - air Exposure index (calculated) PN-Z-04008-7:2002+Az1:2004
32 Workplace environment - air Concentration of harmful dust agents – inhalable fraction
Apatites and phosphorites Portland cement Titanium dioxide Natural graphite Synthetic graphite Kaolin Amorphous and synthetic silica Wood dusts Flour dusts Dusts not classified according to toxicity Organic dusts of animal and plant origin, excluding wood and flour dusts Carbon black Calcium sulfate (VI) (gypsum) Coal (hard, brown) Calcium magnesium carbonate (dolomite) Silicon carbide, non-fibrous Range (0,20 – 20,5) mg/m3
Gravimetric method PN-Z-04507:2022-05+Ap1:2022-08
33 Workplace environment - air Concentration of harmful dust agents – respirable fraction
Apatites and phosphorites Portland cement Natural graphite Amorphous and synthetic silica Organic dusts of animal and plant origin, excluding wood and flour dusts Coal (hard, brown) Range (0,10 – 4,6) mg/m3
Gravimetric method PN-Z-04508:2022-05+Ap1:2022-08
34 Workplace environment - air Carbon monoxide concentration
Range (2,3 – 234) mg/m3
Electrochemical method PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r.
35 Workplace environment - air Exposure index (calculated) PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r.
36 Workplace environment - air Sulphur dioxide concentration
Range (0,13 – 8,5) mg/m3
Spectrophotometric method PN-Z-04015.12:1996+Ap1:2001
37 Workplace environment - whole-body vibration RMS frequency-weighted vibration acceleration.
Range (0,03 - 100) m/s2
Direct measurement method PN-EN 14253+A1:2011
38 Workplace environment - whole-body vibration Daily exposure, expressed as the energy-equivalent for 8 hours of the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz), Exposure lasting 30 minutes and less, expressed as the r.m.s., frequency-weighted vibration acceleration, dominant among the vibration accelerations, determined for the three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated) PN-EN 14253+A1:2011
39 Workplace environment - hand-arm vibration RMS frequency-weighted vibration acceleration.
Range (0,3 -100) m/s2 Daily exposure, expressed as the energy-equivalent for 8 hours of the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy,ahwz). Exposure lasting 30 minutes and less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for three directional components (ahwx, ahwy,ahwz) (calculated)
Direct measurement method PN-EN ISO 5349-1:2004 | PN-EN ISO 5349-2:2004+A1:2015-11
40 Workplace environment - noise A-weighted equivalent sound level. A-weighted maximum sound level.
Range (27 – 136) dB C-weighted peak sound level. Range (27 – 136) dB Noise exposure level referred to: an 8-hour daily working time the average weekly working time (calculated)
Direct measurement method PN-N-01307:1994 | PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11
41 Workplace environment - indoor electric lighting Illuminance
Range (5 - 5000) lx Illuminance uniformity (calculated)
Direct measurement method P B-LCh/P-33 wersja 04 z dnia 17.09.2024 r.
42 Rooms in residential, collective residence and public buildings - air Carbon monoxide concentration
Range (3495 – 233000) μg/m3
Electrochemical method PB-LCh/P-26 wersja 04 z dnia 08.11.2021 r.

Reference standards (39)

Metodyka NIZP PZH ZHK:2007
P B-LCh/P-33 wersja 04 z dnia 17.09.2024 r.
PB-LCh/P-03 wersja 07 z dnia 08.11.2021 r.
PB-LCh/P-26 wersja 04 z dnia 08.11.2021 r.
PB-LCh/W-36 wersja 02 z dnia 08.11.2021 r.
PB-LM/L-09 wersja 07 z dnia 08.11.2021 r.
PN-75/C-04588/01
PN-82/C-04576.08
PN-92/C-04590/03
PN-EN 14253+A1:2011
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN ISO 10523:2012
PN-EN ISO 11731:2017-08
PN-EN ISO 11731:2017-08/ Ap1:2019-12
PN-EN ISO 14189:2016-10
PN-EN ISO 16266-2:2022-04
PN-EN ISO 16266:2009
PN-EN ISO 5349-1:2004
PN-EN ISO 5349-2:2004+A1:2015-11
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 pkt. 7
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-1:2014-12
PN-EN ISO 9308-1:2014-12/ A1:2017-04
PN-EN ISO 9308-2:2014-06
PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11
PN-ISO 6059:1999
PN-ISO 6332:2001
PN-ISO 6332:2001/Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994
PN-N-01307:1994
PN-Z-04008-7:2002+Az1:2004
PN-Z-04015.12:1996+Ap1:2001
PN-Z-04507:2022-05+Ap1:2022-08
PN-Z-04508:2022-05+Ap1:2022-08